Preview only show first 10 pages with watermark. For full document please download

Scando Hd

   EMBED


Share

Transcript

MANUAL SCANDO HD DVI and Analog RGB Computer Video to 3G/HD/SD-SDI Scan Converter with Genlock Input and Fiber Optic Output Installation and Operations Manual WWW.ARTEL.COM ScanDo HD Contents What’s included with your new ScanDo HD . . . . . . . . . . . . . . . . . . . . . . . 3 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Installation Steps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Available Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Video Standard Selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 General Front Panel Operation: Setting the Output Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Moving the Image (Pan) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Sizing the Image (Zoom). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Changing the Image Appearance (Proc Control). . . . . . . . . . . . . . . . 8 Genlock Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Genlock Phasing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Anti-Flicker Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Test Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Restoring to Factory Default Settings . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Locking the Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Fiber Optic Output On/Off. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 On Screen Display (OSD) On/Off. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Capturing & Storing EDID. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Preset Save & Recall Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Image Freeze. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Controlling the ScanDo HD Remotely: Connecting to the Ethernet Port. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Viewing the IP Address. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Connecting to the RS-232 Port. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Certification Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 About Your ScanDo HD and Notes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 ScanDo HD Functions at a Glance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Page 2 ScanDo HD User’s Manual ScanDo HD What’s Included with your ScanDo HD 1 - ScanDo HD DVI-I Computer Video to 3G/HD/SD-SDI Scan Converter 1 - AC Power Line Cord 1 - DVI-I Computer Input Cable 1 - VGA Computer Input Cable 2 - DVI-I Male to HD-15 Female Adapters 1 - CAT5 Ethernet cable 1 - RS-232 Serial Cable 1 - User’s Manual ( This document ) 1 - Remote Control Manual 1 - ScanDo HD Front Panel Quick Reference Chart 1 - Rack Mounting Kit 1 - Accessory Pack ( Replacement fuse, rubber feet ) Available Optional Accessories: • Fiber Matrix Optical Router for 3G/HD/SD signal distribution • Fiber Optic to Electrical Receiver for 3G/HD/SD-SDI optical output • Fiber Optic DVI Extender • Fiber Optic and Coaxial Cables • AC line cords for North America, Japan, UK, Europe or Australia For more about available accessories for your ScanDo HD, please see page 13. ScanDo HD User’s Manual Page 3 ScanDo HD Introduction Thank you for purchasing ScanDo HD, the high-performance DVI-I computer video to 3G/HD/SD-SDI scan converter. With ScanDo HD, you now have the ability to convert your high-resolution DVI computer video sources into a SMPTE standard 3G, HD or SD SDI signal for broadcasting on air or integrating into a professional video production system. ScanDo HD does not require that you install any special software or hardware on your computer. Like all the products from Artel Video Systems, ScanDo HD comes with our continuing commitment to provide support. Should you need to contact us for support, our office is open Monday through Friday, from 8:30 AM to 5:00 PM Eastern Time. Our Singapore office is open Monday through Friday, from 9:00 AM to 5:00 PM Singapore time. We also offer a comprehensive web site for your added convenience. Visit us at scandohd.tv To avoid fire and/or personal injury, please observe these safety and operating precautions: Use the Proper Power Cord. Use only the proper power cord specified for this product and certified for the country of use. Ground the Product. This product is grounded through the grounding conductor of the power cord. To avoid electric shock, the grounding conductor must be connected to the earth ground. Before making connections to the input and output of the product, make sure that the product is properly grounded. Prevent Electrical Circuit Overloading. The unit operates from a single-phase power source with the neutral conductor at or near earth ground. The line conductor is fused for over-current protection. A protective ground connection through the grounding conductor in the power cord is essential for safe operation. Ensure that the available AC line power is sufficient to meet the power requirements of the unit without exceeding the rated load for the supply circuit and its wiring. Observe These Rack Mount Installation Precautions. If the product is to be rack mounted, make sure the following are observed: * The unit operates correctly in ambient temperatures from 0 degrees C to +50 degrees C. Leave space for cooling by ensuring standard side clearance for rack mounting or 2 inches of side clearance for table top use. Also, ensure rear clearance of approximately 3 inches so that cables are not damaged by sharp bends. * Reduced air flow through and around the unit may have an adverse effect on the operation and safety of the unit. Make sure that air flow is adequate to ensure the ambient temperature does not rise above or below the specified levels. When rack mounted, no equipment or other item is to be placed directly on top of the unit as this will make the mounting of the unit unsafe and unstable. Page 4 ScanDo HD User’s Manual ScanDo HD Follow these steps for a simple and successful ScanDo HD Installation Installation Instructions Step 1: Power Off both your computer and the ScanDo HD and disconnect your monitor from the monitor port on your computer. Step 2: Using the supplied DVI input cable and the supplied VGA adapter if necessary, connect one end to the monitor port on your computer and the other to the connector on the rear panel of the ScanDo HD marked DVI-I Input. Step 3: Connect your monitor, if you have one, to the ScanDo HD connector labeled DVI-I Loop Through. See DVI-I Loop Through in the Available Outputs section below. Step 4: Connect the AC line cord provided with the ScanDo HD to the AC power connector. Plug the AC line cord to the wall outlet to provide power. Step 5: Connect the ScanDo HD’s 3G/HD/SD-SDI output to your video equipment. If desired, you may use all outputs simultaneously. (Refer to the next section.) Step 6: Turn On the ScanDo HD first. Then, turn On the monitor. Finally, turn On your computer. The green input LED’s on the front panel labeled Locked and Valid should illuminate, indicating the unit is receiving a valid signal from the computer. Available Outputs 3G/HD/SD-SDI (2): These outputs generate a SMPTE 424M-2006, 292M or 259M compatible serial digital signal. These outputs simultaneously produce the same signal and are not capable of producing two different resolutions. The signal produced at these outputs is determined by the settings for Line Count, Vert Rate, I/P, and Rate Div. Note: If one of the 3G/HD/SD-SDI Outputs is not used, it should be terminated at the connector in 75 ohms to improve the eye pattern of the output that is used. Fiber Optic: This output is an optical version of the copper 3G/HD/SD-SDI outputs. This optical output is in accordance with SMPTE 297-2006 and uses an LC optical connector. This output will support either single mode or multimode (62.5u or 50u) fiber types. The factory default is off. DVI-I Loop Through: This output is for a connection to a local DVI or VGA monitor. It will show what is present on the DVI-I input. The DVI-I Loop Through format (DVI or Analog) must match the DVI-I input format (DVI or Analog). With a DVI monitor attached to this output, the EDID information from the monitor connected to this output will be passed to the computer's DVI port. If no monitor is connected to this output, then the ScanDo HD will provide EDID information to the computer. You may also capture and store a monitors EDID information. See the “Capturing & Storing EDID” section of this manual. Video Standard Selection The output video standard and timing is established by a combination of settings of the Line Count, Vert Rate, I/P, and Rate Div front panel settings. The ScanDo HD will only allow valid SMPTE standards to be chosen. Please refer to the section “Setting the Output Format” for instructions on selecting the video standard from the front panel. ScanDo HD User’s Manual Page 5 Operating the ScanDo HD - General Front Panel Operation ScanDo HD Setting the Output Format Pan IP Address Increase Delay Output Format Output Format Button: Advance Reset Ethernet Decrease Increase Cancel Changes: Delay Advance Decrease Processing Genlock Anti-flicker Line Count: Control Capture Determines the number of active horizontal lines in the image. F1 F2 F3 Increase EDID Store Cancel Zoom Pan IP Address Alternate Function Zoom The desired output format is established by pressing the Output Format button on the front panel. The following represents the output settings you can modify while in Output Format mode: Output Preset Format Select Factory Cancel Defaults then Reset Ethernet Special Operation Notes: For NTSC or PAL output formats, you need only select 483 or 576. All other selections are implied when either of these Line Count selections are made. If, at any time, the ScanDo HD detects that no more valid selections can be made, no additional LEDs will illuminate and it will set your selections as the Output Format after a 2-3 second delay. IP Address Outpu Forma Delay Advance VerticalTest Rate: Genlock Zoom Phasing Determines the base vertical refresh rate of the output. ThisDecrease is the number of Reset Keypanel OSD Fiber frames per second if the output is progressive and the number of fields perEthernet second if the output is interlaced. Cance Recall Rate Division: Determines if the base Vert Rate is to be divided by 1.001 or not. For example, to set the output vertical field rate to 59.94 the user would set the Vert Rate to "60", the Rate Div to "1/1.001". Interlaced/Progressive/Psf: Determines if the output format is to be Interlaced, Progressive or Progressive Segmented Frame (Psf). Not all options are available for all Line Counts and Vert Rates in accordance with SMPTE standards. Note: The allowed output format combinations of the above are specified in the Specifications section of this manual. To set a specific output format: Step 1: If you accidentally enter Output Format mode, please wait 4-6 seconds and the ScanDo HD will not change the Output Format and will exit Output Format mode. Page 6 Pan Press the OUTPUT FORMAT button. Available resolutions will illuminate in the Line Count row. The flashing LED indicates your selection. Use the LEFT and RIGHT Arrow keys to change your desired Line Count. Step 2: After making your Line Count selection, use the DOWN arrow key to navigate to the Vertical Rate row. The available Vertical Rates for your chosen Line Count will illuminate. The flashing LED indicates your selection. Use the LEFT and RIGHT Arrow keys to make your selection. If the default options are desired, go to Step 5. Step 3: After making your Vertical Rate selection, use the DOWN Arrow key to navigate to the Rate Division row. The available Rate Divisions for your chosen Line Count and Vertical Rate will illuminate. The flashing LED indicates your selection. Use the LEFT and RIGHT Arrow keys to make your selection. If the default options are desired, go to Step 5. Step 4: After making your Rate Division selection, use the DOWN arrow key to navigate to the Interlaced, Progressive & Psf row. The valid Interlaced, Progressive or Psf settings will illuminate and the default selection will blink. Use the LEFT and RIGHT arrow keys to make your selection. If the default options are desired, go to Step 5. Step 5: Press the OUTPUT FORMAT button. The LEDs will illuminate momentarily. After a few seconds, only your selections will remain illuminated. The Output Format has now been changed and is active. ScanDo HD User’s Manual Operating the ScanDo HD - General Front Panel Operation ScanDo HD Moving the Image PAN: Press PAN to enter Pan Mode. The LED to the right of the button will light to indicate the function is active. Use the LEFT, RIGHT, UP or DOWN ARROW keys to position your image. Press and hold for a series of fine steps followed by a more coarse adjustment. PAN Button Operation Enter Pan Mode nlock F3 Genlock nlock F3 asing Pressing certain combinations of arrow buttons simultaneously will perform specific functions when in the Pan mode: Pan IP Output Processing Processing Increase Address Pan Pan Format Control Control IP IP Capture Capture Cancel Delay Processing Advance Increase Increase Address Address Pan EDIDEDID Control Zoom IP Capture Reset Decrease Delay Delay Advance Advance Increase EDID Ethernet ZoomZoom Address * UP and DOWN arrows: Centers the image vertically Move Left or Right Processing ber Genlock Control Phasing Capture F3 EDID Fiber or Processing Control Move Up or Down Capture Increase EDID Processing Genlock Control Phasing Capture Processing EDIDProcessing nlock Fiber Control Control Capture Capture F3 EDIDEDID Delay Center horizontally F3 nlock asing F3 ber Genlock Phasing Processing Fiber nlock Control asing Capture Genlock berEDID F3 Processing Control Capture Genlock EDID Phasing Fiber Processing Control Capture Processing EDID Control Capture ProcessingEDID Control * LEFT and UP arrows: Places the top left corner of the input image in the top left Output corner of the Format output Advance Delay + Lower left corner + Upper right corner Advance PanDecrease IP Decrease Address PanIncrease Zoom IP Delay Reset Address Ethernet Decrease Increase Lower right corner Delay Advance Cancel Decrease Zoom Pan IP Zoom Button Operation Increase Address Processing Processing Control Control Capture Capture EDID EDID Genlock F3 Processing Control Decrease Zoom Capture Output Format Cancel Zoom Reset Ethernet Pan Pan Increase Zoom IP IP Address Address Increase Increase Delay Delay Advance Advance Full Screen, both H & V: Zoom Output Format Cancel Reset Ethernet ZOOM: This button will size the image either by increasing or decreasing the visible size in the raster. The UP and DOWN arrows are used to increase and decrease respectively the size of the image. Press and hold for a series of fine steps followed by a more coarse adjustment. When in H&V mode, both the Horizontal and Vertical outputs will be affected. When in H Only mode, only the Horizontal output will be affected. When in V Only mode, only the Vertical output will be affected. Output Output Format certain combinations of arrow buttons simultaneously will perform Format Pressing Cancel Cancel specific functions when in the Zoom mode: Pan IP Address Output Format * UP and DOWN arrows: Zooms the image in one direction while keeping the Cancel Delay PanAdvance Zoom input aspect ratio the same by proportionately zooming the opposite + IP Output Reset Increase Decrease Address Pan Pan Format direction. Ethernet Full Screen, maintain aspect ratio: Processing Genlock Control Phasing Capture Processing EDIDProcessing nlock Fiber Control Control Capture Capture F3 Genlock EDIDEDIDProcessing Control Capture nlock F3 EDID asing Processing ber Genlock Control Phasing Capture EDID Fiber Zoom Zoom Reset Reset Increase Ethernet Ethernet Decrease Decrease EDID Zoom Ethernet Output Advance Format + Sizing the Image Advance Cancel arrows: Places the bottom right corner of the input image in * RIGHT and DOWN Output Format the bottom right corner of the output Cancel Reset Reset Ethernet Decrease Delay Cancel Output Format Output Reset Format Ethernet Pan IP Cancel Address + Advance Cancel Cancel * RIGHT and UP arrows: Places the top right corner of the input image in the top Output Formatof the output right corner Delay Processing Increase Control Capture Delay EDID + + Capture EDID * LEFT and DOWN arrows: Places the bottom left corner of the input image in the bottom left corner of the output Reset Advance Advance Pan Ethernet ZoomZoom IP Reset Reset Decrease Decrease Increase Address Pan Ethernet Ethernet IP Increase Delay Advance Pan Address Zoom IP Reset Delay Advance Decrease Increase Address Zoom Ethernet Decrease Delay Delay Upper left corner Choose Decrease Parameter Cancel ResetReset Pan PanAdvance Ethernet Ethernet Zoom IP IP Output Reset Decrease Increase Address Address Format Ethernet Cancel Cancel PanAdvance Zoom Zoom IP Output Reset Decrease Reset Increase Decrease Address Pan Pan Ethernet Format Ethernet IP IP Cancel Output Output Advance Increase Increase Address Format Format Zoom Address Delay Center vertically nlock asing F3 ber Genlock Cancel Cancel Output * LEFT and RIGHT arrows: Centers the image horizontally Format Delay Decrease Decrease or Output Output Format Format Delay Advance Increase Increase + Cancel Output IP IP Output Address Pan Zoom Address Format Format When in Cancel H Only or V Only mode, the UP and DOWN arrows provide IP Reset Cancel Decrease Output Delay Delay Advance Advance Increase Ethernet ZoomZoom Address Format a 1:1 input/output ratio. 1:1 Ratio, when in Cancel ResetReset Decrease Decrease Delay PanAdvance Ethernet Ethernet Zoom H Only or V Only + IP Output Reset Increase Decrease Address modes: Formatand Right arrows: Zooms the image to full screen both horizontally and * Ethernet LEFT Cancel Delay Advance vertically when in H&V mode, horizontally when in H Only mode, Zoom and vertically when in V Only mode. Reset Decrease Ethernet ScanDo HD User’s Manual Page 7 Operating the ScanDo HD - General Front Panel Operation ScanDo HD PROCESSING CONTROL: This function alters the displayed image's appearance by varying the Brightness, Contrast, Hue, Saturation and Sharpness. The PROCESSING CONTROL button is pressed to sequence through the different image process functions. Once the desired function is selected, use the UP and DOWN arrows to increase or decrease respectively the degree of augmentation to that image parameter. Changing the Image Appearance Processing Control Button Operation F1 F3 Processing Control Capture EDID Processing Genlock ore Genlock Anti-flicker Control Choose Parameter F2 F3Capture EDID Processing call GenlockTest Control Phasing Capture panel Fiber F3 OSD EDID Processing Genlock Control Phasing Capture EDID Fiber Increase Delay Processing Genlock IncreasePhasing orControl Decrease Capture Fiber Setting EDID or Increase Pan IP Decrease Address Increase Delay Advance Delay Delay Advance Reset Setting + Decrease Increase PanAdvance Zoom IP Reset Decrease Address Ethernet F2 F3 Recall Test Genlock Phasing Keypanel OSD Fiber Turn On/Off F1 Preset Select Factory Defaults Preset Select Factory nlock Defaults F3 Processing nlock Control asing Capture berEDID nlock F3 Cancel Reset Ethernet The GENLOCK button turns the genlock mode On and Off. When the genlock mode is on, the unit looks at the genlock input and determines if a signal is present. During this time the Searching LED will be lit. If a signal is present, the unit determines if its format is compatible with the output format selected. If the genlock input is valid, the Locked LED will illuminate. Genlock Button Operation Genlock Zoom Reset Output Ethernet Format Cancel Genlock Anti-flicker Pan Zoom Output IP Decrease Reset Format Address Ethernet Cancel Zoom Output Reset Format Ethernet Zoom Decrease Store Pan Pan IP Output simultaneously, while in the PROCESSING IP Pressing the UP and Output Increase AddressDOWN arrows Format Address Format CONTROL mode, will return the active function to its default state. Cancel Delay Advance Cancel Advance Processing Control Capture EDID The ScanDo HD will accept either NTSC/PAL composite video or HD tri-level sync. Pan the output vertical rate in order to achieve The genlock vertical rate must match IP Increase genlock but the horizontal rates do not have toOutput match. Therefore, it is possible to Address Format Cancel lock to an NTSC signal and produce a 1080i/59.94 output, for example. Delay Advance Zoom Decrease Reset Ethernetmode off. The factory default setting is genlock To genlock the ScanDo HD, connect a genlock signal to the Genlock Input connector on the rear panel. There is a passive loop through from the genlock input which is accessible on the Genlock Loop Through connector. NOTE: If the Genlock Loop Through is not used, it should be terminated at the connector in 75 ohms. Genlock Phasing Store Genlock Anti-flicker Genlock Phasing ButtonF3Operation F1 F2 Recall Test Genlock Phasing Keypanel Processing Control Capture EDID OSD Fiber Choose Parameter Pan SetProcessing Advance Advance Zoom Reset Increase Increase Ethernet Decrease DelayDelay + Advance Advance Decrease Decrease ber Page 8 Advance IP Decrease Address Increase nlock asing Decrease Reset Ethernet When the desired genlock phasing mode is enabled, use the DELAY and ADVANCE IP Outputyour selection. Pressing the DELAY and ADVANCE buttons buttons to edit Address Format simultaneously Cancel will reset the phasing mode to zero offset. Pan Delay Reset Offset to Zero Pan IP Outputthrough the three LEDs to select Press the GENLOCK PHASING button Increase Addressto sequence Format the parameter to phase. Cancel Delay Advance Zoom Increase Set Delay ProcessingDelay Control Control Capture Capture EDIDEDID Processing Control Capture EDID The GENLOCK PHASING button, along with the DELAY and ADVANCE arrow buttons will allow for phasing the output of the ScanDo HD relative to the genlock reference. Horizontal, Vertical and Pixel Clock phasing can be adjusted. Zoom Output Reset Format Ethernet Cancel Pan Pan NOTE: For NTSC and PAL output formats, set the Vertical Phasing to Zero Offset before adjusting any phasing. IP IP Address Address Output Output Format Format NOTE: Clock Phasing movement is in 840 picosecond (pS) increments and may Cancel Cancel ZoomZoom not be visible on some TV waveform monitors and rasterizers. ResetReset Ethernet Ethernet ScanDo HD User’s Manual Operating the ScanDo HD - General Front Panel Operation ScanDo HD The ANTI-FLICKER button will step through 8 levels of flicker reduction. This function is used primarily for interlaced output settings to reduce vertical flicker at the expense of vertical detail. Anti-Flicker Function Anti-Flicker Button Operation Auto Mode Alternate Function Alternate Function Alternate Function Preset Manual Select Mode Factory Defaults Store Anti-flicker F1 F2 Store Recall Anti-flicker Test F1 Keypanel F2 OSD Store Recall Anti-flicker Test Preset Increase Anti-Flicker Select F1 Factory Level ( 18 ) Keypanel Defaults Preset Select Factory Defaults F2 OSD Alternate Function Preset EDID Genlock Fiber Genlock F2 F3 Anti-flicker Test F1 Keypanel F2 OSD Recall Test Defaults OSD Control Capture EDID Fiber Factory Defaults Button Operation then Store Lock/Unlock Button Operation F1 Preset Recall Select Preset Alternate Select Function Factory Defaults Alternate Lock/Unlock then Factory Function Keypanel Defaults Fiber Optic Output On/Off Store Genlock Anti-flicker On/Off Button Operation F1 F2 Alternate Function Preset Select Factory Defaults Recall Test Alternate OSD Keypanel Function Turn On/Off ScanDo HD User’s Manual F3 Genlock Preset Phasing Select Factory Fiber Defaults then Anti-flicker Anti-flicker Genlock Genlock Processing Processing Control Control Capture Capture EDID EDID PanPan IP IP F1 F1 F2 F2 F3 F3stored presets will remain intact when Increase Increase Note: Any previously resetting ScanDo HD Address Address to factory defaults. Delay Delay Advance Advance Genlock Genlock Preset Preset Select Select Factory Factory Defaults Defaults Locking the Button Panel Output You may quickly return all ScanDo HD functions to their factory default settings by pressing the ALTERNATE FUNCTION button and then the FACTORY DEFAULTS button. Store Store Factory Defaults Zoom IP Reset Address Ethernet Increase Decrease Format These test patterns can be enabled by pressing the TEST button. The first press Cancel Delay Advance will generate the 100% Color bars signal. TheZoom second press will generate the Reset off the test signal generator and 75% color bar signal and theDecrease next press will Ethernet shut return to the converted output. Restoring to Factory Default Settings Alternate Alternate Function Function Output Format Reset Address Ethernet Decrease Increase ScanDo HD will generate several test signals in place of the converted Processing Pan video output: Control IP Capture Output •EDID 100% Color bars Increase Address Format Processing • 75% Color bars Delay Cancel Advance Pan Genlock Phasing 2x Cancel Pan Zoom IP Reset Address Ethernet Ethernet Genlock Genlock Phasing F3 Fiber 1x Advance If OSD is enabled, the Delay mode and value of the Anti-Flicker Cancel function will be shown in Advance Zoom the upper left corner of the Decrease output display. Reset Test Signals Anti-flicker Store Recall Select 75% Color Bars Keypanel Factory Capture EDID F3 Fiber OSD Delay Pressing the ANTI-FLICKER button will put the function in manual mode and the Output the anti-flicker level LED will be lit. Sequential pressing Decrease Increase of the button will increase Format from 1 (least reduction) to 8 (most reduction). Pressing it again after level 8 will Cancel Processing Delay Advance Pan Control Zoom extinguish the LED and return the function to auto mode. IP WhilePhasing Led is on Keypanel Format Processing Control Capture EDID Genlock Phasing Until Led is on F3 Fiber Genlock Phasing Select 100% Color Bars Factory Defaults F3 Test Test Button Operation F1 Preset Until Led is off Recall Store Alternate Function When the ANTI-FLICKER LED is off, the function is in automatic mode where the Processing best level of flicker reduction is selected for you Pan based on the input and output Control IP timing Captureparameters detected. Output Increase Address Genlock Recall Recall TestTest Phasing Phasing Keypanel Keypanel OSD OSD Fiber Fiber Zoom Zoom Outpu Ou Forma For Cance Can Reset Reset Ethernet Ethernet Decrease Decrease The front panel may be locked or unlocked by pressing the ALTERNATE FUNCTION button and then the KEYPANEL button. If the keypanel is locked, the Keypanel Processing Store GenlockProcessing Anti-flicker Pan LED will illuminate. Genlock Anti-flickerLocked Pan Control Control F2 F1 Test Recall OSDKeypanel F3F2 Genlock Test Phasing OSD Fiber F3 Capture EDID Capture EDID Delay Advance Delay Genlock Phasing Increase IP Address Increase Fiber Advance Zoom DecreaseReset Ethernet Decrease IP Output Address Format Outpu Forma Cancel Zoom Cance Reset Ethernet The fiber optic output may be turned On and Off by pressing the ALTERNATE FUNCTION button and then the FIBER button. If the fiber optic output is on, the Fiber Optics On LED will illuminate. Store Processing Anti-flicker Control F1 CaptureF2 EDID Genlock Recall Test Genlock Delay Phasing Keypanel OSD F3 Fiber Processing Control Capture Increase EDID Advance Decrease Pan Pan IP Address Zoom Reset Ethernet IP Address Output Increase Format Delay Cancel Decrease Advance Zoom Reset Ethernet Page 9 Outpu Forma Cance t t y ts Operating the ScanDo HD - General Front Panel Operation ScanDo HD On Screen Display (OSD) On/Off On/Off Button Operation Preset Select Factory Defaults Store Anti-flicker F1 F2 Recall Alternate Function Keypanel Alternate Turn On/Off Function The OSD feature of the ScanDo HD may be turned On and Off by pressing the ALTERNATE FUNCTION button and then the OSD button. If the OSD is on, the OSD On LED will illuminate. Store Genlock Preset Test Select then Factory OSD Genlock Alternate F3 Function Anti-flicker Capture & F2Store F1 Recall Test Genlock Phasing Keypanel OSD Fiber Processing Control Capture EDID Increase Processing Genlock Control CaptureF3 EDID Pan Pan IP Note: OnF2Screen Displays are active on all SDI outputs and appear live on-air. IP will Output Increase Address Address Format It is recommended to turn OSD on only when configuring your ScanDo HD Advance Cancel Delay Advance Delay Genlock Genlock Zoom Recall offline. Test Zoom Phasing Phasing F3F1 Keypanel Fiber Defaults OSD Fiber Cance Reset Ethernet ResetDecrease Ethernet Decrease Outpu Forma ScanDo HD allows you to capture Processing and store the EDID information from a DVI Store Genlock Anti-flicker Control monitor connected to the DVI-I Loop Through port. When EDID informationPan is IP Capture F1 F2 F3 Increase stored, ScanDo HD will pass this information to the computer connected toAddress the EDID DVI-I Input port upon the computers start-up. Delay Advance Genlock Capturing & Storing EDID Store Anti-flicker Processing Preset Control Select Capture Factory EDID Defaults Recall then Test Phasing Outpu Forma Cance Zoom Pan Reset IP OSD Fiber Output Ethernet If no EDID information is stored, will use its builtDecrease in EDID intelligence Increase AddressScanDo HD Format and pass the best possible match to the computer. Wether EDID information is Cancel Delay Advance stored or not, ScanDo HD willZoom always pass the EDID information of any DVI moniReset Decrease tor connected to the DVI-I Loop EthernetThrough port. Keypanel Capturing & Storing EDID: To capture and store EDID information in ScanDo HD, connect a DVI monitor to the DVI-I Loop Through port and power it on. Press the ALTERNATE FUNCTION button and then the CAPTURE EDID button. Your EDID is now stored. Erasing EDID Information: To erase any previously stored EDID information, detach any monitor connected to the DVI-I Loop Through port and press the ALTERNATE FUNCTION button and then the CAPTURE EDID button. Preset Operation Enter Preset Store Mode Preset Preset Select Select Factory Factory Defaults Defaults Enter Preset Recall Mode Alternate Alternate Function Function Store Store Anti-flicker Anti-flicker F1 F1 F2 F2 Recall Recall Test Test OSD OSD Preset Select Factory Defaults Change Preset Position Store Store Execute Preset Store Preset Preset Select Select Factory Factory Defaults Defaults F1 F1 F2 F2 Recall Recall Test Test Keypanel OSD OSD Execute Preset Recall Keypanel Alternate Alternate Function Function F1 Genlock Phasing PhasingF2 Fiber Fiber Page 10 Alternate Function Preset Select Factory Defaults IP Address then Output Format Cancel Output Output Format Format Cancel Cancel Note: After recalling or storing a preset the respective preset LED will remain Delay Advance Delay Advance Zoom Zoom illuminated. However, should you make any configuration changes (Zoom, Pan, Reset Decrease Reset Decrease etc), this LED will extinguish as the modified configuration no longer matches the Ethernet Ethernet stored configuration. ScanDo HD allows you to freeze the outputs at any time. This allows you to change your source material without displaying the operation live and on-air. To freeze the output, press the ALTERNATE FUNCTION button and then the F1 Processing Store Anti-flicker Pan Control button. The Valid Genlock input LED will blink if the output is frozen. F1 Preset Store Select Factory F1 Defaults IP IP Address Address Increase Increase Genlock Genlock Phasing Phasing Fiber Fiber On/Off Button Operation Turn On/Off Zoom Zoom Increase Reset Reset Ethernet Ethernet Decrease Decrease Capture Capture EDID EDID F3 F3 Image Freeze On/Off Alternate Function Capture EDID F3 Recall a Preset: Press the RECALL button. Positions with a valid preset to recall Delay Advance Genlock willTest illuminate. The flashing LED indicates your current selection Press Zoom the PRESET Recall Phasing Reset button Press the RECALL button. Keypanel SELECT OSD Fiberuntil the desired preset LED is flashing.Decrease Ethernet ScanDo HD willProcessing now reconfigure and your chosen preset LED will remain Genlock Anti-flicker Pan Control Genlock Anti-flicker Pan illuminated. Processing Control Keypanel Keypanel Alternate Function Store Creating a Preset: Configure the various features of ScanDo HD to your liking. Press the STORE button. ScanDo HD has 6 Preset LEDs, one for each storage position. If there are any previously stored presets, their respective LEDs will Processing Genlock Pan Control Genlock Panthe PRESET SELECT illuminate. TheProcessing flashing LED is your current selection. Press Control IP Capture Output F3 IP Capture Increase Output Address F3 button until the EDID LED of your desired save position is flashing. STORE butFormat Increase Address Press the EDID Format Processing Cancel ton. All preset LEDs except your chosen position will extinguish. Genlock Anti-flicker Pan Delay Advance Cancel Control Delay Genlock Advance Anti-flickerRecall F2 Keypanel F2 Test Genlock F3OSD Recall Test Genlock Phasing Keypanel OSD Fiber F3 Capture EDID IP Address Increase Delay GenlockProcessing Phasing Control Fiber Capture EDID Increase Delay Advance Pan Decrease IP Address Advance Decrease Zoom Zoom Reset Output Ethernet Format Cancel Reset ScanDo HD User’s Manual Ethernet Outpu Forma Cance Operating the ScanDo HD - Controlling the ScanDo HD Remotely ScanDo HD ScanDo HD can be controlled remotely in two ways. A standard Ethernet port can be used to control the unit using a standard browser (i.e. Internet Explorer, Firefox) enabled with Java version 1.6 (JRE 6) or later. It can also be controlled using ASCII command strings through the RS-232 serial port. Connecting to the Ethernet Port 10/100 BASE-T: The rear panel Ethernet port will accept a standard 10/100 Base-T Ethernet connection. The unit will automatically adjust to either speed from the hub, switch or router that it is connected to. The default setting for the unit is to accept an IP address from the router to which it is connected. This is referred to as DHCP mode. Viewing the IP Address To see the IP settings the unit has acquired from the router after the connection is made, ensure that the On Screen Display is enabled and press the ALTERNATE FUNCTION button and then the IP ADDRESS button. ScanDo HD’s IP address will appear on-screen for 30 seconds. If you connect the ethernet cable after you have powered on your ScanDo HD, you may have reset the ethernet port by pressing the ALTERNATE FUNCTION and then the RESET ETHERNET button. The unit may also be assigned an IP address manually. Please refer to your ScanDo HD Remote Control manual. IP Address Button Operation Processing Processing Control Control Capture Capture EDID EDID Alternate Function Increase Increase View the IP Address Delay Delay Preset Pan Pan Select IP Factory IP Address Defaults Address then Advance Advance Alternate Function Decrease Decrease Reset Ethernet Port Preset Zoom Zoom Select Reset Factory Reset Ethernet Defaults Ethernet then Connecting to the RS-232 Port Processing Store Anti-flicker Once the ScanDo Genlock HD is connected, launch the browser on your PC. Control Capture the IP address of the unit. InF1 the Address bar of the browser enter F2 F3 Increase EDID For example: http://192.168.1.54 Delay Advance IP Address F2 F3 control screen of the ScanDo HD. Fiber You will OSD now see the IP Reset Address Ethernet Store Recall F1 Output Keypanel Output Format Format Cancel Cancel Recall Anti-flicker Test Test Genlock Phasing Processing Control Capture EDID Genlock Decrease Increase Delay Advance Pan Pan Zoom Zoom Phasing Note: It is important that your browser have Java version 1.6 (JRE 6) or laterReset Decrease Keypanel OSD Fiber installed. This is normally standard on most browsers. However, the latest Ethernet version of Java can be downloaded at: java.sun.com RS-232: This port is designed to work with a standard RS-232 serial port. The signalling parameters are: 19200, 8, N, 1 There is no hardware or software flow control and Generic TTY should be used. A "straight-through" DB-9 M/F cable should be used when connecting to a standard PC. ScanDo HD is designed to be DCE equipment. The following pins on the DB-9F connector are used: 2 - Data Transmit from ScanDo HD 3 - Data Receive into ScanDo HD 5 - Signal Ground A complete list of commands can be found in the ScanDo HD Remote Control manual. ScanDo HD User’s Manual Page 11 Outpu Forma Cance Outpu Forma Cance ScanDo HD Nothing seems to be working Troubleshooting • Are any of the green LEDs lit on the front panel? If not, check to make sure that the AC power cord is connected and plugged into the AC wall outlet and the power switch on the rear panel is On. • Check to make sure that the computer is properly sending out a DVI-D or analog RGB signal by plugging the monitor directly into the computer’s video output. There is no video on the DVI Loop-thru or the SDI outputs • It is important for most PC's with a DVI output to have the DVI monitor connected at the time the PC is booted. When using the ScanDo HD with a PC having a DVI output, make sure the ScanDo HD's DVI input is connected to the PC's DVI output and the ScanDo HD is On before the PC is booted. Failure to do so may cause the PC to fail to recognize a DVI monitor is connected and shut off all DVI signalling from the DVI output of the PC. • Press the TEST button to see if you get color bars on the SDI outputs. If you do get color bars, then the problem is related to your input signal. Check the items mentioned in the above bullet. If you do not get color bars, the problem is related to your output. • When using a laptop, try turning off the laptop’s LCD screen and having the video signal output through the external port only. The color on the TV monitor is different than the computer monitor • The colors on your SDI monitor will never exactly match the colors on your computer monitor because each of these devices reproduce color differently. It is also likely that the color temperature of each monitor is set differently. There is no fiber optic output • Check to make sure that Fiber Optic Output is turned On by pressing the ALTERNATE FUNCTION button and then the FIBER button. The factory default setting is off. For additional support, please visit artel.com or scandohd.tv Page 12 ScanDo HD User’s Manual Accessories ScanDo HD The following accessories are available for ScanDo HD. They may be ordered from your dealer or directly from Artel Video Systems Advanced 3G Signal Routing FiberLink Matrix FiberLink Matrix is a fully configurable and SMPTE compliant 32x32 optical router. The inputs and outputs can be ordered in quantities of one and the input and output quantities do not have to match providing you with the ability to build a Matrix that is ideal for your specific application and budget! Available with LC or ST connectors, FiberLink Matrix is fully compliant with SMPTE 297-2006, supports up to 3G-SDI data rates and works with both single mode and multimode fiber. Redundant power supplies offer operational confidence. Best of all, the entire enclosure is only 3 RU high! Convert ScanDo’s Optical Output to Copper FiberLink 3350 Series The FiberLink 3350 Series allows you to transmit 3G, HD or SD-SDI as per SMPTE 424M-2006, 292 and 259, with or without embedded audio and data, as well as DVB-ASI over one single mode or multimode fiber. Signals are equalized and re-clocked prior to fiber optic transmission. The 3350 transmitter features a reclocked and equalized SDI loop through and the 3351 receiver features two re-clocked and equalized SDI outputs. The 3350 Series is compliant with SMPTE 297-2006 and has the ability to operate seamlessly with FiberLink Matrix and other SMPTE 297-2006 fiber optic compliant devices. The 3350 Series is immune to pathological signals over the entire budget link and operating temperature range. DVI over Fiber FiberLink 7500 Series The FiberLink 7500 Series supports DVI transmission (up to 1920x1200) and stereo audio over one single mode or multimode fiber without compression, scaling or adjustments. It is ideal for broadcast or corporate studios! The 7500 transmitter box provides a convenient DVI loop-thru port and the 7501 receiver provides 2 DVI outputs along with stereo audio. The 7500 transmitter will generate EDID information internally, acquire it via the DVI loop-thru, or you may capture and store EDID information. Cabling Fiber Optic Cable We can provide you with optic cable of varying types and lengths. Fiber optic cabling is available in PVC, Plenum and Armor Jacketed. Please contact a Sales Representative today. Please visit artel.com for the latest products, specifications and other breakthrough products. ScanDo HD User’s Manual Page 13 ScanDo HD FCC Statement WARNING: This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart B of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference in which case the user, at his own expense, will be required to take whatever measures may be required to correct the interference. CE Information Standards to which conformity is declared: EMC EN 55022: 1994, CISPR 22: 1993, Class A Limit EN 50082-1: 1992 IEC 801-2: 1991 IEC 801-3: 1984 IEC 801-4: 1988 FDA & IEC Statement Turn off unit or laser before connecting or disconnecting optical cable! Complies with FDA performance standard for laser products, Title 21, Code of Federal Regulations, Sub-Chapter J and IEC 60825-1 The fiber optic transmitting element in the ScanDo HD contains a solid state Laser Diode located within the optical connector. This device emits invisible infrared electromagnetic radiation which can be harmful to human eyes. The radiation from this optical connector, if viewed at close range without a fiber optic cable connected to the optical connector, may be of sufficient intensity to cause instantaneous damage to the retina of the eye. Direct viewing of this radiation should be avoided at all times. WARNING TO REDUCE THE RISK OF FIRE OR ELECTRONIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. CAUTION RISK OF ELECTRIC SHOCK. DO NOT OPEN! CAUTION TO REDUCE THE RISK OF ELECTRONIC SHOCK, DO NOT REMOVE COVER. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. This symbol warns the user of uninsulated voltage within the unit that can cause dangerous electronic shocks. Page 14 Certification This symbol alerts the user that there are important operating and maintenance instructions in the literature accompanying this unit. In the literature accompanying this unit, this symbol warns the user of dangerous conditions to avoid. ScanDo HD User’s Manual Specifications ScanDo HD Input Resolutions Input/Output Output Resolutions Video Processing Genlock Processing Controls Image Size & Positioning Control Interfaces Additional Features Dimensions Power ScanDo HD User’s Manual • DVI-I single link resolutions • RGB, Progressive or Interlaced, up to 1920 x 1200 @ 60 Hz • Pixel clock frequency 25 to 165 MHz • Input: DVI-D, or DVI-I single link with active loop-through • Coaxial SDI output x 2; per SMPTE 424M-2006 Level A, 292M & 259M-C • Optical SDI output x 1; per SMPTE 297-2006 (1310 nm, single mode or multimode, LC, -3.5 dBm nominal output power) 10-bit 3G-SDI per SMPTE 242M-2006: • 1080/60/P • 1080/59.94/P 10-bit HD-SDI per SMPTE 292M: • 720/60/P • 720/59.94/P • 720/29.97/P • 720/25/P • 1035/60/I • 1035/59.94/I • 1080/50/I • 1080/30/P • 1080/29.97/Psf • 1080/25/P • 1080/24/Psf • 1080/23.98/P 10-bit SD-SDI per SMPTE 259M: • 525/59.94/I (NTSC) • 625/50/I (PAL) • 1080/50/P • 720/50/P • 720/24/P • 1080/60/I • 1080/30/PsF • 1080/25/PsF • 1080/23.98/PsF • 720/30/P • 720/23.98/P • 1080/59.94/I • 1080/29.97/P • 1080/24/P • 10-bit, all digital • NTSC/PAL black burst or HD tri-level sync • 3G/HD resolutions will genlock to NTSC/PAL black burst at the same vertical rate • Passive loop-through • H, V and Clock phasing with a range of one output vertical period and resolution of 840 pS • Brightness • Color Saturation • Contrast • Sharpness • Hue • Separate H & V positioning • Zoom and Shrink; H & V separate or together • 10/100 Base-T ethernet LAN port with internal HTML host • RS-232 port • Front panel push button • Variable flicker reduction • Test pattern generator: color bars at 100% and 75% Saturation • Multiple pre-set storage and recall settings • On Screen Display (OSD) • Factory defaults reset • Rack mount kit included • RoHS compliant • 16.75 W (without rackmount ears) x 1.75 H x 10 D (inches) • 425 W x 44 H x 254 D (mm) • Weight: 5.5 pounds; 2.49 kg • Internal universal input AC power supply • 95 - 250 volts AC, 47 - 63 Hz, 20 watts, 68.24 BTU/Hr Page 15 ScanDo HD About Your ScanDo HD Serial Number: Date of Purchase: Purchased From: Installed By: Installation Location: Configuration: Page 16 ScanDo HD User’s Manual ScanDo HD ScanDo HD User’s Manual Notes Page 17 Blue Front Panel Quick Reference Chart ScanDo HD White Output Format Button Operation Processing Control Button Operation Black Pan Increase ay IP Address Edit Output Format Advance Store Output Anti-flicker Format F1 F2 Cancel Pan Store Genlock Anti-flickerStore F1 F3 F2 Processing Anti-flicker Genlock Control Choose Parameter F2 F3Capture EDID F1 Processing Control Capture EDID Increase GenlockProcessing Control F3 Capture EDID Store Keypanel Lock/Unlock Button Operation F1 Change Value Change Line Delay or Fiber Optic Output Cancel F2 On/Off Button F1Operation + Zoom Reset Ethernet Cancel Store Turn On/Off F1 Anti-flicker Pan Preset Recall Test IP Output Processing Processing Select Increase Alternate Store Anti-flicker Address enlock k Pan Pan Format Control Control Function Keypanel OSD Factory Defaults IP IP Capture Capture Cancel F1 F2 Output Output Delay Processing Advance F3 Genlock Increase Increase Address Address Pan EDIDEDID Control Format Format Zoom IP Capture Cancel Cancel Output Reset Decrease F3 DelayDelay Advance Advance Increase EDID enlock k Preset Ethernet Recall Test Format ZoomZoom Address hasing g Select Alternate Processing Processing ResetReset Keypanel Delay Decrease Decrease Function OSD Cancel PanAdvance Factory Fiber Genlock Control Pan Processing Control Store Genlock Anti-flicker Ethernet Zoom Defaults Ethernet Control Phasing IP Capture IP Capture Output Output F3 Reset Increase Capture Decrease Increase EDID Address Fiber EDID F1 F2 F3 Address Format Format Ethernet EDID Enter Pan Mode Choose Parameter Move Up or Down or Center vertically + Center horizontally + F1 Recall F3 Genlock Phasing Genlock Fiber F3 F2 Pan IP Address Preset Advance Recall Test Delay Preset Zoom Pan Reset Defaults Ethernet IP Address Select Alternate Select On/Off then FunctionKeypanel Factory OSD Factory ProcessingAlternate Control Function Capture EDID Decrease Defaults Increase Image Freeze Decrease On/Off Button Operation Pan Fiber Anti-flicker Increase Delay Genlock Phasing Keypan Defaults Store On Screen Display On/Off Button OperationF1 Genlock Phasing Button Operation or Store F3 Genlock Preset Phasing Test Processing Control Capture EDID Genlock F2 Reset Ethernet Genlock Select Alternate On/Off then Factory OSD Keypanel Function Fiber Genlock Button Operation Decrease Move Left or Right Recall F1 Test Recall Outp Form OSDKeypan Canc Lock/Unlock then or Reset Setting or Advance PAN Button Operation Increase or Decrease Setting then F2 Pan Preset Recall IP Select Output Address Format Factory Keypanel Defaults Cancel Zoom Pan Preset IP IP Alternate Select Output Increase Alternate Increase Address Address Function Format Function Factory Defaults Delay CancelAdvance Advance Pan Zoom Zoom Output IP Decrease Reset Decrease Output Reset Format Address Ethernet Store Format Anti-flicker Ethernet Pan Zoom Processing Delay Delay Processing Genlock Store Genlock Anti-flicker IP PanAdvance Genlock Store Anti-flicker OutputGenlockTest Recall Test Control Reset Preset Recall Decrease Preset Increase Recall Test Preset Control Phasing Address Phasing FormatPhasing Select Ethernet Select Alternate Alternate Select Alternate IP Capture Capture F1 F2 Factory F3F2 Factory Function Keypanel OSD Fiber Increase Function F1 F3 OSD Decrease Keypanel Fiber Address EDID Function Increase OSD Factory Cancel Fiber EDID Processing Processing Delay Advance Keypanel Defaults nlock ck Defaults PanPan Defaults Control Control Zoom Cancel Delay Advance Processing Delay IP IP Capture Capture Store Genlock Anti-flicker PanAdvance Output Output GenlockAddress Processing F3 Reset Phasing Preset Zoom Recall Test Recall Control Decrease Increase Increase Genlock Preset Zoom Test Address Pan EDID EDID Format Format Phasing Control Ethernet Select e Select Alternate IP Capture Output Reset F1 F2 F3 Decrease n Reset IP Keypanel OSD Factory Decrease Capture Address EDID Function Cancel Cancel Output Increase Keypanel OSD Fiber Factory F3Defaults Format Ethernet Delay Delay Fiber Advance Advance Increase Address nlock ck EDID Preset Ethernet Format Defaults Zoom Zoom ng asing Select Alternate Cancel Delay Advance Genlock Processing Cancel Reset Reset Function Delay Advance Decrease Decrease Factory Preset Zoom Recall Test Pan ber Genlock Phasing Control Ethernet Ethernet Zoom Defaults Select e Phasing Reset IP Decrease Capture n Output Keypanel OSD Increase Fiber Factory Reset Decrease Ethernet Address EDID Fiber Format Defaults Ethernet Cancel Changes: Anti-flickerStore Advance Store Genlock F3F1 Genlock Recall Phasing Keypan Fiber Zoom Store Reset Ethernet F1 IP Output Increase Address Format Preset Recall Store Anti-flicker Select Cancel Processing Cancel Alternate Delay Advance Processing Delay Advance Pan Cancel Function Genlock Control Store Delay Advance Genlock Anti-flicker Zoom Pan Zoom Factory Genlock Control F1 F2 Keypan Phasing Preset Zoom Recall Test Defaults Phasing IP Select Output Alternate Capture Reset IP Capture Reset Increase Decrease Output Address EDIDProcessing F1Processing F2 F3Decrease enlock k Function Fiber Pan Pan Ethernet Format Reset Increase Decrease Ethernet Address Control Control Keypanel OSD FiberEDID Factory Format Ethernet Defaults IP IP Capture Capture Cancel Output Preset Recall Test Output Delay Advance F3 Cancel Processing Increase Increase ProcessingDelay Advance Address EDIDEDID Select StoreStore Genlock Genlock Anti-flicker Genlock Zoom Address Anti-flicker Pan Pan Alternate Format Control Control Format Preset Zoom Recall Test Phasing Function Keypanel OSD Factory Select Sto IP IP Cancel Capture Reset Capture Cancel Processing Decrease Output OutputDefaults F1 F1 Delay F2Delay F3Advance F2 F3Advance enlock Reset Increase PanEDIDEDID Decrease k Increase Address Address Ethernet ZoomZoom Keypanel Fiber actory Control OSD Format Format Ethernet hasing g efaults F1 IP Capture Processing Output F3 Genlock Cancel Reset Reset Cancel Decrease Decrease Increase Pan DelayDelay Advance Advance Address Fiber EDID Control Genlock Format Genlock Ethernet Ethernet Preset ZoomZoom RecallRecall Test Test Preset Phasing Phasing SelectSelect Sto lternate IP Capture Alternate Cancel Output F3 Processing Increase Delay Advance Preset Rec Address Anti-flicker EDIDKeypanel enlock Decrease Processing ResetReset PanStore Genlock Decrease Format unction Pan Function FiberFiber Factory Keypanel OSD OSD Factory Control Zoom Control Ethernet Select Alternate Ethernet hasing Defaults Defaults F1 Function IP Capture Cancel Keypa Factory IP Capture Delay AdvanceReset F3 O F2Output F3 Decrease Increase Increase AddressF1Zoom Fiber EDID Genlock Defaults Address EDID Format Fo Ethernet Phasing Cancel Reset Processing Ca Decrease Processing Preset Rec Delay Advance Delay Advance Processing Fiber Store Genlock Anti-flicker Pan enlock Pan Store Genlock Anti-flicker Genlock Ethernet Control Control Select Zoom Preset Zoom Recall Test Alternate Control Processing hasing Store Phasing Genlock Anti-flicker P Select Function Alternate Control Keypa Factory IP Capture IP Capture Processing Increase Output Capture O F2 F3 Reset F1 Pan Genlock Reset F1 Fiber F2 Until Led isF3 Increase Decrease off Defaults Address FiberEDID Function Decrease Address Increase EDID Keypanel OSD Factory Format EDID Fo Control Capture Ethernet Ethernet F1 F2 F3 Defaults Increase Ad EDID IP Capture Output Cancel Address F3 Ca Processing Processing Delay Advance Delay Advance EDID Delay PanIncrease Store Genlock Anti-flickerFormat Genlock Pan Advance GenlockControl Control Zoom Preset Zoom Advance Recall Test Preset Recall Test Processing Delay Phasing Phasing Store Genlock Anti-flicker P Select Alternate Alternate Select Control IP Preset Zo Recall Test Capture Cancel IP Capture Output Delay Reset Advance Phasing Processing F1 F2 Anti-flicker Reset Decrease Decrease Increase Genlock Increase Led isFiber on EDID Processing Function Decrease Address Select Store Store Genlock Genlock Anti-flicker EDID Keypanel OSD Fiber F3 OSDUntil Factory Address PanPan Function Format Alternate Keypanel Factory Zoom Capture Ethernet Control Control Ethernet Phasing F1 F2 F3 Re Defaults Decrease Increase Defaults Function Ad Keypanel OSD Fiber Factory EDID Sto IP IPEth Capture Capture Cancel Reset Decrease Defaults Delay Advance F1 F1 F2 F2 Genlock F3 F3 Delay Advance Increase Increase Fiber Address Address EDID EDID Ethernet Zoom Preset Zoom Recall Test Processing Delay Advance Phasing F1 Store Genlock Anti-flicker P Select Control Pan Alternate Preset Zo Recall Test Phasing Reset Reset Decrease Delay Delay Advance Advance Decrease While Led is on FunctionEthernet Select OSD Factory Preset Genlock Genlock Alternate Capture Ethernet Zoom Preset Keypanel Recall ZoomRe Recall TestTest Fiber IP F1 F2 F3 Defaults Decrease Phasing Phasing Increase Output Function Select Ad Keypanel OSD Fiber Factory EDID Select Increase Sto Alternate Alternate Address Eth Format Processing Preset Rec Defaults Reset Reset Genlock Anti-flicker Decrease Decrease Pan Function Function Keypanel Keypanel OSD OSD Fiber Fiber Factory FactoryStore Control Select Alternate Ethernet Etherne Delay Advance Defaults Defaults Cancel F1 Delay Advance Genlock Function Keypa Factory IP Capture Preset Zo Recall Test O F1 F2 F3Processing Zoom Phasing EDID Increase Defaults Processing Address Store Pan Fo Store Genlock Anti-flicker Alternate Anti-flicker Select Genlock Control Control Re Decrease Function Reset Keypanel OSD FiberProcessing Factory Decrease Eth Sto IP Advance Ca Capture Capture Output Preset Delay Rec Store Genlock Ethernet Pan F1 F2 Defaults F3Anti-flicker F1 GenlockEDID F2 F3 Control Increase Address Increase Ad EDID Preset Zoom Recall Test Format Select Alternate Phasing Select IP Capture Alternate F1 Function O Keypa Factory F1 F2 F3 Processing Increase Cancel Processing Reset Address Processing Advance Decrease EDID Delay Function Fo Keypanel Genlock OSD FactoryPan Defaults Delay Pan Store Fiber Genlock Anti-flicker Control Control Genlock Ethernet Advance Control Preset Zoom Recall Test Defaults Preset Phasing Z Recall Test Phasing Select IP Capture Ca Alternate Select IP Output Capture Alternate Delay Advance Capture Output Increase Genlock F1 F2 F3 Reset Address EDID Increase Preset Rec Decrease R Increase Address Format EDID Function Decrease Preset Zoom Recall Keypanel Fiber Test Keypanel PhasingOSD Factory Ad EDID Function OSD Factory Format Fiber Ethernet Select Et Alternate Select Defaults Alternate Defaults Cancel Function Reset Keypa Factory Cancel Decrease Delay Advance Function Advance Factory Processing Delay Keypanel OSD Fiber Delay Genlock Pan Ethernet Advance Defaults Zoom Genlock Control Zoom Defaults Preset Z Recall Test Phasing Select Alternate IP Capture Reset Decrease Output Reset F3 Decrease R Increase Decrease Function Address EDID Keypanel OSD Fiber Factory Ethernet Format Ethernet Et Defaults Processing Cancel Delay Advance Pan Genlock Control Zoom Phasing IP Capture Processing Processing Output Store Store Genlock Genlock Anti-flicker Anti-flicker Processing Processing Reset Increase Decrease Address EDID Control Control nlock Fiber Pan Pan Ethernet Format Control Control Capture Capture F1 F1 F2 F2 F3 F3 Cancel IP IP Capture Capture Delay Advance Output Output F3 Genlock EDID EDID Increase Increase Address Pan EDIDEDIDProcessing Zoom Address Format Format Control nlock F3 asing Set Delay On/Off then Set Advance Upper left corner Lower left corner Upper right corner Lower right corner Reset Offset to Zero + Anti-Flicker Button Operation + Auto Mode + Manual Mode + Increase Anti-Flicker Level ( 1- 8 ) Zoom Button Operation Choose Parameter 100% Color Bars Decrease Zoom 75% Color Bars Full Screen, maintain aspect ratio: + Full Screen, both H & V: + Decrease Delay Delay IP Reset Advance Advance Increase Ethernet ZoomZoom Address Advance Decrease Enter Edit Mode then Change Value or Change Line or Save Changes then Cancel Changes then Reset Ethernet Port then 1x 2x Cancel Cancel Output Format Preset Preset Select Select Alternate Alternate Factory Defaults Functionthen Factory Cancel Function Factory ResetReset Advance 1:1 Ratio, when in Decrease Decrease Delay Pan Ethernet Ethernet Zoom H Only or V Only + IP Output Reset Increase Decrease Address modes: Format Ethernet Page 18 then Factory Defaults Button Operation Processing ber Genlock Control Phasing Capture EDID Fiber Delay View the IP Address Test Button Operation Increase Zoom Capture EDID Ethernet Settings Button Operations + Zoom Reset Ethernet Cancel Defaults Defaults Recall Recall TestTest Genlock Genlock Phasing Phasing (978) 263-5775 Keypanel Keypanel OSD OSD | artel.com Fiber Fiber Check for ScanDo Updates at: scandohd.tv ScanDo HD User’s Manual ScanDo HD ScanDo HD User’s Manual Page 19 Proven Products, Unrivaled Service, and Great Support • Proven technology in a rugged, reliable package • Training and installation support available • 24x7x365 technical support available Artel Video Systems Corp. 5B Lyberty Way, Westford, MA 01886 USA T: 978-263-5775 F: 978-263-9755 www.artel.com [email protected] [email protected] All specifications subject to change without notice. ©2016 Updated 02/17/2016 CS200-127982 -00_D