Transcript
Messgeräte Sonstige Daten
Spectrometer Probes i::scan
fluor::lyser II
Ionselective Probes
fluor::lyser II monitors fluoride and temperature
∙∙ s::can plug & measure
Physical Probes
∙∙ measuring principle: ISE (ionenselektive elektrodes) ∙∙ no cross sensitivities in typical drinking water applications ∙∙ multiparameter probe ∙∙ long term stable, factory precalibrated ∙∙ automatic cleaning with compressed air
Terminals
∙∙ easy and quick mounting and measurement directly in the media (InSitu) or in a flow cell (monitoring station) ∙∙ operation via s::can terminals & s::can software ∙∙ ideal for drinking water
Software
∙∙ minimal maintenance ∙∙ plug connection or fixed cable
System Configuration
recommended accessories part number article name carrier oxi::lyser / soli::lyser / s::can ISE probes F-11-oxi-ammo F-45-ammo flow cell for ammo::lyser™ F-45-process process connection 1/4" G C-210-sensor 10 m extension cable for s::can physical probes and s::can ISE probes B-44 cleaning valve
Monitoring Stations Spare Parts & Accessories Services & Solutions
46
cable type housing material weight (min.) dimensions (diameter x length) operating temperature storage temperature installation / mounting process connection pH range protection class automatic cleaning
Ionselective Probes
PU jacket 2x2x0.25 stainless steel 1.4571, POM-C 2.7 kg 60 x 326 mm 0 ... 60 °C 0 ... 60 °C submersed or in a flow cell G 1 1/2" outside 4.5 ... 7.5 IP68 media: compressed air permissible pressure: 2 ... 4 bar air volume: 3 ... 9 liters per cleaning cleaning duration: 4 ... 12 seconds per cleaning cleaning interval: 30 … 120 minutes, depending on application delay: 10 … 30 seconds
i::scan
ISE F: ionophore membrane reference electrode measuring range application 0.05 ... 1000 mg/l automatic compensation instrument temperature OH- (at >pH8), Al3+, Ca2+, Fe3+, potential interfering ions Si4+ precalibrated ex-works all parameters integration via con::lyte 1 con::lyte 2 con::lyte 4 con::nect con::cube power supply 10 ... 30 VDC power consumption (typical) 0.72 W sys plug, IP68, RS485, 12 VDC interface connection to s::can terminals cable length 7.5 m fixed cable (-075) or plug connection (-000)
Spectrometer Probes
technical specification measuring principle measuring principle detail
drinking water
min. max.
part number E-542-000 / -075
Physical Probes
fluor::lyser II
typical concentration ranges for this application F temperature [mg/l] [°C] 0.05 0 2 60
Terminals Software System Configuration Monitoring Stations Spare Parts & Accessories Services & Solutions
47