Transcript
General Purpose Relays Force Guided Relays
SCHRACK
Force Guided Relay SR4 D/M n 4
pole relay with force guided contacts according to EN 50205 design & space efficient
n Compact
Typical applications Emergency shut-off, press control, machine control, elevator and escalator control, safety relays F0244-C
ZT Approvals
Coil Data (continued)
Technical data of approved types on request
Coil versions, DC-coil Coil Rated Operate Release Coil Rated coil code voltage voltage voltage resistance power VDC VDC VDC Ω±10% mW 021 21 16.0 2.1 551 800 024 24 18.0 2.4 720 800 036 36 27.0 3.6 1620 800 040 40 30.0 4.0 2000 800 048 48 36.0 4.8 2880 800 060 60 45.0 6.0 4500 800 085 85 63.8 8.5 9031 800 110 110 83.0 11.0 15125 800
VDE 40005334, UL E214024, TUV 968/EL 230, CQC 0617015578
Contact Data
Contact arrangement 3 form A + 1 form B contacts 3 NO + 1 NC 2 form A + 2 form B contacts 2 NO + 2 NC Rated voltage 250VAC Max. switching voltage 400VAC Rated current 8A Contact material AgSnO2 Contact style single contact, force guided type A according to EN 50205 Min. recommended contact load 5V/10mA Initial contact resistance ≤100mΩ at 1A, 24VDC ≤20Ω at 10mA, 5VDC Frequency of operation, with/without load 6/150min-1 Contact ratings, IEC60947-5-1, on 1 form A (NO) contact AC15-3A DC13-3A Mechanical endurance 10x106 operations
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Insulation Data
Coil data
Coil voltage range
5 to 110VDC
Coil versions, DC-coil Coil Rated Operate Release Coil Rated coil code voltage voltage voltage resistance power VDC VDC VDC Ω±10% mW 005 5 3.8 0.5 31 806 006 6 4.5 0.6 45 800 009 9 6.8 0.9 101 802 012 12 9.0 1.2 180 800 015 15 11.3 1.5 281 801 018 18 13.5 1.8 405 800 05-2012, Rev. 0512 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company
Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section.
Initial dielectric strength between open contacts 1500Vrms between contact and coil 4000Vrms between adjacent contacts 2500Vrms Clearance/creepage between open contacts microdisconnection between contact and coil ≥10/10mm between adjacent contacts ≥3/3.5mm Insulation to EN 50178, type of insulation between contact and coil reinforced between adjacent contacts basic
Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change.
1
General Purpose Relays Force Guided Relays
SCHRACK
Force Guided Relay SR4 D/M (Continued) Other Data
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content refer to the Product Compliance Support Center at www.te.com/customersupport/rohssupportcenter Ambient temperature -25 to 70°C Category of environmental Protection IEC 61 810 RTIII Weight 30g Resistance to soldering heat THT IEC 60068-2-20 260°C/5s Packaging/unit tube/10 pcs.
For more detailed information see product specification 2158002
PCB layout / terminal assignment Bottom view on solder pins
S0413-BC
2 form A + 2 form B, 2 NO + 2 NC contacts
S0413-BB
Dimensions
3 form A + 1 form B, 3 NO + 1 NC contacts
S0413-BA S0412-BH
Product code structure
Typical product code SR4 D 4 012
Type SR4 Relay with force guided contacts SR4 Contact arrangement D 2 form A + 2 form B contacts (2 NO + 2 NC) M 3 form A + 1 form B contacts (3 NO + 1 NC) Contact material 4 AgSnO2 Coil Coil code: please refer to coil versions table (e.g. 012=12VDC) Other types on request
2
05-2012, Rev. 0512 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company
Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section.
Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change.
General Purpose Relays Force Guided Relays
SCHRACK
Force Guided Relay SR4 D/M (Continued) Product code
Type
Contact arrangement Contact material
Coil
Part number
SR4D4005 4 pole 2 form A + 2 form B, AgSnO2 5VDC 7-1415054-1 SR4D4006 relay with 2 NO + 2 NC 6VDC 8-1415054-1 SR4D4009 force guided contacts contacts 9VDC 9-1415054-1 SR4D4012 12VDC 1415055-1 SR4D4018 18VDC 1-1415055-1 SR4D4021 21VDC 2-1415055-1 SR4D4024 24VDC 3-1415055-1 SR4D4036 36VDC 4-1415055-1 SR4D4040 40VDC 5-1415055-1 SR4D4048 48VDC 6-1415055-1 SR4D4060 60VDC 7-1415055-1 SR4D4085 85VDC 8-1415055-1 SR4D4110 110VDC 9-1415055-1 SR4M4005 3 form A + 1 form B, 5VDC 5-1415053-1 SR4M4006 3 NO + 1 NC 6VDC 6-1415053-1 SR4M4009 contacts 9VDC 7-1415053-1 SR4M4012 12VDC 8-1415053-1 SR4M4018 18VDC 9-1415053-1 SR4M4021 21VDC 1415054-1 SR4M4024 24VDC 4-1415053-1 SR4M4036 36VDC 1-1415054-1 SR4M4040 40VDC 2-1415054-1 SR4M4048 48VDC 3-1415054-1 SR4M4060 60VDC 4-1415054-1 SR4M4085 85VDC 5-1415054-1 SR4M4110 110VDC 6-1415054-1
05-2012, Rev. 0512 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company
Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section.
Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change.
3