Preview only show first 10 pages with watermark. For full document please download

Scn-manager - Atx Networks

   EMBED


Share

Transcript

SCN-Manager ® RF Signal Management Forward Narrowcast Combining Units & Return Combining Unit Overview SCN-4010NCF Forward Unit (front view) Forward Narrowcast Combining Unit: Features & Benefits:  RF outputs for up to 24 transmitters  Combines broadcast with targeted narrowcast signals  Migration path for narrowcast services (1:24, 1:12, 1:8, 1:4, 1:2, 1:1)  SCN-4010NCFL - similar version with 4 dB less insertion loss is also available. Achieved by not supporting the 1:24 & 1:12 Narrowcast insertion ports  Consistent RF performance parameters on all narrowcast inputs make migration easy & efficient  Optimized isolation for analog & digital signals  Tremendous rack space savings  No rewiring of network as narrowcast targeting requirements change Forward Narrowcast Combining Unit (SCN-4010NCF) Specifications Ordering Information Part Number SCN-4010NCF Description Forward Narrowcast Combining Platform, F Connectors Page 1 of 5 Specifications subject to change without notice. SCN-Manager ® RF Signal Management Forward Narrowcast Combining Unit: Functional Schematic OUTPUT 1 1:24 BROADCAST (-24 dB) TEST POINT 1 (-20 dB) 1:12 NARROWCAST (-36 dB) 1-12 NARROWCAST (-36 dB) 1:8 NARROWCAST (-36 dB) 1-8 13-24 1:4 NARROWCAST (-36 dB) 9-16 1-4 1:2 NARROWCAST (-36 dB) 1-2 17-24 1:1 NARROWCAST (-36 dB) 1 21-24 OUTPUT 24 23-24 24 TEST POINT 24 (-20 dB) Forward Narrowcast Combining Unit (rear view) Page 2 of 5 Specifications subject to change without notice. SCN-Manager ® RF Signal Management Low Loss Forward Narrowcast Combining Unit: Low Loss Forward Narrowcast Combining Unit (SCN-4010NCFL) Specifications Ordering Information Part Number SCN-4010NCFL Description Forward Narrowcast Combining Platform, Low Loss, F Connectors Functional Schematic OUTPUT 1 TEST POINT 1 (-20 dB) 1:24 BROADCAST (-26 dB) 1:8 NARROWCAST (-32 dB) 1-8 1:4 NARROWCAST (-32 dB) 9-16 1-4 1:2 NARROWCAST (-32 dB) 1-2 17-24 1:1 NARROWCAST (-32 dB) 1 21-24 OUTPUT 24 23-24 24 TEST POINT 24 (-20 dB) Page 3 of 5 Specifications subject to change without notice. SCN-Manager ® RF Signal Management Return Combining Unit: Features & Benefits:  Provides combined outputs from up to 16 optical receivers  Migration path for combined return signals (1:16, 1:8, 1:4, 1:2, 1:1)  Multiple 1:2 & 1:1 outputs for further future-proofing  Consistent RF performance parameters on all narrowcast inputs make migration easy & efficient  Optimized isolation for all return signal formats  Tremendous rack space savings  No rewiring of network as return signal combining ratio requirements change Return Combining Unit (SCN-4011RCF) Specifications Ordering Information Part Number SCN-4011RCF Description Return Combining Platform, F Connectors Page 4 of 5 Specifications subject to change without notice. SCN-Manager ® RF Signal Management Return Combining Unit: Functional Schematic 16:1 COMBINED OUTPUT (-21 dB) 8:1 COMBINED OUTPUTS (-21 dB) INPUT 1 TEST POINT 1 (-20 dB) 1-16 1-8 4:1 COMBINED OUTPUTS (-21 dB) 1-4 9-16 13-16 2:1 COMBINED OUTPUTS (-21 dB) 1-2 1:1 OUTPUTS (-21 dB) 1 15-16 INPUT 16 TEST POINT 16 (-20 dB) 16 Return Combining Unit (rear view) SCN-Manager® is a registered trademark of ATX in the United States and/or other countries. Products or features contained herein may be covered by one or more U.S. or foreign patents. Other non-ATX product and company names mentioned in this data sheet are the property of their respective companies. ISO 9001 Specifications subject to change without notice. Tel (905) 428-6068 Printed in Canada REGISTERED 1-501 Clements Road West, Ajax, ON L1S 7H4 Canada Toll Free (800) 565-7488 Fax (905) 427-1964 Toll Free Fax (866) 427-1964 www.atxnetworks.com [email protected] Page 5 of 5 Rev. 04/15 (ANW0663)