Transcript
SCN-Manager
®
RF Signal Management
Forward Narrowcast Combining Units & Return Combining Unit Overview
SCN-4010NCF Forward Unit
(front view)
Forward Narrowcast Combining Unit: Features & Benefits: RF outputs for up to 24 transmitters Combines broadcast with targeted narrowcast signals Migration path for narrowcast services (1:24, 1:12, 1:8, 1:4, 1:2, 1:1) SCN-4010NCFL - similar version with 4 dB less insertion loss is also available. Achieved by not supporting the 1:24 & 1:12 Narrowcast insertion ports Consistent RF performance parameters on all narrowcast inputs make migration easy & efficient Optimized isolation for analog & digital signals Tremendous rack space savings No rewiring of network as narrowcast targeting requirements change
Forward Narrowcast Combining Unit (SCN-4010NCF) Specifications
Ordering Information Part Number SCN-4010NCF
Description Forward Narrowcast Combining Platform, F Connectors
Page 1 of 5 Specifications subject to change without notice.
SCN-Manager
®
RF Signal Management Forward Narrowcast Combining Unit: Functional Schematic
OUTPUT 1 1:24 BROADCAST (-24 dB)
TEST POINT 1 (-20 dB)
1:12 NARROWCAST (-36 dB) 1-12
NARROWCAST (-36 dB)
1:8 NARROWCAST (-36 dB) 1-8 13-24
1:4 NARROWCAST (-36 dB) 9-16
1-4
1:2 NARROWCAST (-36 dB) 1-2
17-24
1:1 NARROWCAST (-36 dB) 1
21-24
OUTPUT 24 23-24
24
TEST POINT 24 (-20 dB)
Forward Narrowcast Combining Unit (rear view)
Page 2 of 5 Specifications subject to change without notice.
SCN-Manager
®
RF Signal Management Low Loss Forward Narrowcast Combining Unit: Low Loss Forward Narrowcast Combining Unit (SCN-4010NCFL) Specifications
Ordering Information Part Number SCN-4010NCFL
Description Forward Narrowcast Combining Platform, Low Loss, F Connectors
Functional Schematic OUTPUT 1 TEST POINT 1 (-20 dB)
1:24 BROADCAST (-26 dB)
1:8 NARROWCAST (-32 dB) 1-8 1:4 NARROWCAST (-32 dB) 9-16
1-4
1:2 NARROWCAST (-32 dB) 1-2
17-24
1:1 NARROWCAST (-32 dB) 1
21-24
OUTPUT 24 23-24
24
TEST POINT 24 (-20 dB)
Page 3 of 5 Specifications subject to change without notice.
SCN-Manager
®
RF Signal Management Return Combining Unit: Features & Benefits: Provides combined outputs from up to 16 optical receivers Migration path for combined return signals (1:16, 1:8, 1:4, 1:2, 1:1) Multiple 1:2 & 1:1 outputs for further future-proofing Consistent RF performance parameters on all narrowcast inputs make migration easy & efficient Optimized isolation for all return signal formats Tremendous rack space savings No rewiring of network as return signal combining ratio requirements change
Return Combining Unit (SCN-4011RCF) Specifications
Ordering Information Part Number SCN-4011RCF
Description Return Combining Platform, F Connectors
Page 4 of 5 Specifications subject to change without notice.
SCN-Manager
®
RF Signal Management Return Combining Unit: Functional Schematic 16:1 COMBINED OUTPUT (-21 dB)
8:1 COMBINED OUTPUTS (-21 dB)
INPUT 1 TEST POINT 1 (-20 dB)
1-16
1-8 4:1 COMBINED OUTPUTS (-21 dB) 1-4
9-16
13-16 2:1 COMBINED OUTPUTS (-21 dB) 1-2 1:1 OUTPUTS (-21 dB) 1 15-16
INPUT 16 TEST POINT 16 (-20 dB)
16
Return Combining Unit (rear view)
SCN-Manager® is a registered trademark of ATX in the United States and/or other countries. Products or features contained herein may be covered by one or more U.S. or foreign patents. Other non-ATX product and company names mentioned in this data sheet are the property of their respective companies.
ISO 9001
Specifications subject to change without notice.
Tel (905) 428-6068 Printed in Canada
REGISTERED
1-501 Clements Road West, Ajax, ON L1S 7H4 Canada Toll Free (800) 565-7488 Fax (905) 427-1964 Toll Free Fax (866) 427-1964 www.atxnetworks.com
[email protected]