GROUND EQUIPMENT A-UNIT (ANALOG LINE UNIT) FEATURES •
Supports up to three channels
•
24-bit Delta-Sigma A/D Conversion
•
Multi-path telemetry routing
•
Automatic error-free data recovery from 43-second (@ 2 ms) on-board shot memory
Total Harmonic Distortion:
Rejection:
Non-real time recording support for increased overall channel
0.0003%
130 dB @ ƒN (Nyquist)
capacity
Channel Matching:
Passband ripple: ± 0.1 dB
•
Low distortion test oscillator to test channels and geophones
DC Removal:
•
In-field programmable firmware allows batch upgrades to be
Common Mode Rejection:
Dynamic (6 dB/octave, corner
performed on all devices connected to the Central System
at 1.5 Hz)
•
Redundant power capability
Time Standard:
Static (zero phase shift)
•
Supports power down the cable (PDC)
Digital Low-Cut Filter:
•
SPECIFICATIONS*
Better than 1.0% 120 dB or greater +/- 1 ppm (-40 ˚C to +70 ˚C)
Crossfeed Isolation:
3 Hz (ON or OFF, as desired)
Slope = 12 dB/octave
120 dB or greater
Sample Rate:
Frequency Response:
Operating Voltage:
1/2 ms, 1 ms, 2 ms or 4 ms
1.5 Hz to 750 Hz
Dynamic Range:
Digital Anti-Alias Filters:
130 dB @ 0 dB gain
Linear or Minimum Phase filters
129 dB @ 12 dB gain
750 Hz @ ½ ms sample rate
121 dB @ 24 dB gain
375 Hz @ 1 ms sample rate
110 dB @ 36 dB gain
187.5 Hz @ 2 ms sample rate
146 dB Total Dynamic Range
94 Hz @ 4 ms sample rate
Maximum Input:
2500 mV peak, 1768 mV RMS @ 0 dB gain
625 mV peak, 442 mV RMS @ 12 dB gain
156 mV peak, 110 mV RMS @ 24 dB gain
39.1 mV peak, 27.6 mV RMS @ 36 dB gain
Input Impedance:
Differential mode: 22.1 kΩ in parallel with 0.049 μF
Common mode: 5.5 kΩ in parallel with 6.6nF
PHYSICAL Packaging:
Aluminum alloy case, plastic cable top
Size:
20.8 cm x 9 cm x 5.5 cm (8.2” x 3.5” x 2.2”)
Weight:
Equivalent input noise (terminated input):
.76 μV RMS @ 0 dB gain
Operating Temperature:
.23 μV RMS @ 12 dB gain
.14 μV RMS @ 24 dB gain
Humidity:
.13 μV RMS @ 30 dB gain
1.0 kg (2.2 lb) -40 ˚C to +75 ˚C 0% - 100%
*Analog performance specifications are typical values at 25 °C and at
Water Depth:
2 ms sample rate
SCORPION
9 VDC — 15 VDC
15 m operational (fresh water)
© 2010 INOVA Geophysical Equipment Ltd. All rights reserved. Information subject to change without notice. Revised December 2010. 1018-040016I
Corporate Headquarters 12200 Parc Crest Drive Stafford, TX 77477 p +1.281.552.3800 f +1.281.552.3811 www.inovageo.com
GROUND EQUIPMENT D-UNIT (DIGITAL LINE UNIT) FEATURES •
Supports up to three VectorSeis® digital receivers (nine channels)
•
Multi-path telemetry routing
•
Automatic error-free data recovery from 30-second (@ 2 ms) on-board shot memory
•
Non-real time recording support for increased overall channel capacity
• •
Built-in support for performing instrument and VectorSeis® receiver tests
PHYSICAL
In-field programmable firmware allows batch upgrades to be
Packaging:
performed on all devices connected to the Central System
•
Redundant power capability
•
Supports power down the cable (PDC)
Aluminum alloy case, plastic cable top
Size:
20.8 cm x 9 cm x 5.5 cm (8.2” x 3.5” x 2.2”)
SPECIFICATIONS Sample Rate:
Weight:
1 ms, 2 ms or 4 ms
1.0 kg (2.2 lb)
Channel Matching:
Operating Temperature:
Better than 1.0%
-40 ˚C to +75 ˚C
Time Standard:
Humidity:
+/- 1 ppm
0% - 100%
DC Removal:
Operating Altitude:
Dynamic (6 dB/octave, corner at 1.5 Hz)
Static (zero phase shift)
Up to +5,500 m
Water Depth: Operating Voltage:
15 m operational (fresh water)
9 VDC — 15 VDC
SCORPION
© 2010 INOVA Geophysical Equipment Ltd. All rights reserved. Information subject to change without notice. Revised December 2010. 1018-040016I
SCORPION recording system
GROUND EQUIPMENT XLU (CROSS LINE UNIT)
FEATURES •
Connects receiver line to cross line
•
Supports analog geophone and VectorSeis® (digital sensor) operations
•
Multi-path telemetry routing
•
Three cross-line ports for improved layout flexibility
•
Two receiver line ports
•
Supports fiber optic cross line cable up 15 km in length
•
In-field programmable firmware allows batch upgrades to be performed on all devices connected to the Central System
•
Redundant power capability
•
Supports power down the cable (PDC)
CAPABILITIES
SPECIFICATIONS Maximum distance between XLUs:
15 km
Operating Voltage:
9 VDC — 15 VDC
Analog receiver line capacity (real-time):
PHYSICAL
•
954 channels @ 2 ms, 30 meter takeout interval
Packaging:
(28.6 km maximum live spread / line)
•
954 channels @ 2 ms, 55 meter takeout interval
(52.5 km maximum live spread / line)
Size:
•
474 channels @ 2 ms, 80 meter takeout interval
(37.9 km maximum live spread / line)
Aluminum alloy case
26 cm x 28 cm x 22 cm (10.2” x 11.0” x 8.7”)
Weight: Digital receiver line capacity (real-time): •
930 stations (2790 channels) @ 2 ms, 30 meter takeout interval
(27.9 km maximum live spread / line)
•
636 stations (1908 channels) @ 2 ms, 55 meter takeout interval
(35 km maximum live spread / line)
•
426 stations (1278 channels) @ 2 ms, 80 meter takeout interval
(34 km maximum live spread / line)
7.9 kg (17.4 lb)
Operating Temperature:
-40 ˚C to +75 ˚C
Humidity:
0% - 100%
Operating Altitude: Cross line Capacity:
Up to +5,500 m
7,500 channels real time at 2ms sample interval Water Depth:
Multi-line Capacity:
15 m operational (fresh water)
Up to 120 lines
SCORPION
© 2010 INOVA Geophysical Equipment Ltd. All rights reserved. Information subject to change without notice. Revised December 2010. 1018-040016I
Corporate Headquarters 12200 Parc Crest Drive Stafford, TX 77477 p +1.281.552.3800 f +1.281.552.3811 www.inovageo.com
GROUND EQUIPMENT BBU (BATTERY BOOSTER UNIT)
FEATURES •
Connects at mid-span connector on receiver line
•
Dual hot-swappable power inputs
•
Two receiver line ports
•
In-field programmable firmware allows batch upgrades to be performed on all devices connected to the Central System
•
Supports power down the cable (PDC)
•
SmartPower™ redundancy and switching (additional equipment may be required)
•
Serial port for connecting HDU (Hand-held Deployment Unit)
CAPABILITIES
PHYSICAL
Powers the following analog receivers using A-Units:
Packaging:
•
48 analog receivers up to 33 m intervals
•
45 analog receivers up to 45 m intervals
•
42 analog receivers up to 55 m intervals
Size:
•
30 analog receivers up to 80 m intervals
Aluminum alloy case
26 cm x 24.8 cm x 14.8 cm (10.2” x 9.8” x 5.8”)
Powers the following VectorSeis® receivers using D-Units:
Weight:
•
36 VectorSeis receivers up to 33 m intervals
•
27 VectorSeis receivers up to 45 m intervals
•
24 VectorSeis receivers up to 55 m intervals
Operating Temperature:
•
18 VectorSeis receivers up to 80 m intervals
5.1 kg (11.2 lb)
-40 ˚C to +75 ˚C
SPECIFICATIONS
Humidity:
Operating Voltage:
0% - 100%
9 VDC — 15 VDC Operating Altitude:
Output Voltage:
Up to +5,500 m
±24 VDC Water Depth:
SCORPION
15 m operational (fresh water)
© 2010 INOVA Geophysical Equipment Ltd. All rights reserved. Information subject to change without notice. Revised December 2010. 1018-040016I
SCORPION recording system
GROUND EQUIPMENT DATABRIDGE WIRELESS BACKBONE The DataBridge Wireless Backbone provides improved crew productivity in areas characterized by man-made and natural obstacles such as rivers, canyons, highways and railroads. The DataBridge backbone consists of two antennas mounted on industrial-standard tripods that provide seamless line connectivity via 802.11g wireless communications. Spread deployment effort is minimized, allowing more time for production recording.
FEATURES & CAPABILITIES
Operating Range:
•
High-gain, directional, flat-panel antennas provide wide
1 km with 1000 channels at 2 ms sample rate (typical).
territorial coverage with minimal signal attenuation:
Greater than 1 km at reduced data rates
* Maintains wireless connectivity when line-of-sight is
Telemetry:
partially obstructed.
Up to 1,000 channels at 2 ms, real-time
* Reduces aiming and set-up inaccuracies via a wide aperture beam.
PHYSICAL — ANTENNA
•
DataBridge Unit (DBU) for managing the timing and control of the
Adjustable 8 to 40 ft (with TeleMast™ tripod)
wireless backbone.
Size:
Hand-held Deployment Unit (HDU) provides quality control at the
time of deployment:
Weight:
* Ensures proper antenna alignment
•
11 cm x 19.4 cm x 4.5 cm (4.3” x 7.7” x 1.8”) 0.5 kg (1.1 lb)
* Tests available data transmission bandwidth •
* Verifies GPS lock status
SPECIFICATIONS — DBU
Industrial-standard tripods ensure the secure and stable
Ports:
mounting of the antennas
Dual hot swappable power inputs
Cross line port
SPECIFICATIONS — ANTENNA
Radio port (power over Ethernet)
Operating Frequency:
Operating Voltage:
2.412 GHz to 2.484 GHz
(licensing subject to local regulations)
Power Consumption:
Integrated Panel Antenna:
HDU
12 dBi
Beam Width Horizontal/Vertical:
9 VDC — 15 VDC 8.2 Watts typical Serial port (shared with either power port)
40 degrees
Wireless Protocol:
PHYSICAL — DBU
Size:
802.11 g
Output Power:
Weight:
21 dBm
Receiver Sensitivity:
25.5 cm x 25.5 cm x 16.5 cm (10” x 10” x 6.5”) 5.1 kg (11.2 lb)
802.11 g
-91 dBm @ 6 mbps
-76 dBm @54 mbps
-88 dBm @ 12 mbps
-70 dBm @ 108 mbps
Humidity:
-82 dBm @ 36 mbps
Operating Temperature:
SCORPION
-30 ˚C to +70 ˚C 0% - 100%
© 2010 INOVA Geophysical Equipment Ltd. All rights reserved. Information subject to change without notice. Revised December 2010. 1018-040016I
Corporate Headquarters 12200 Parc Crest Drive Stafford, TX 77477 p +1.281.552.3800 f +1.281.552.3811 www.inovageo.com
GROUND EQUIPMENT CABLES FEATURES •
Integral twisted-pair line cable with hermaphroditic Dynacon™ quick-couple, mid-span connectors
•
Bi-directional power, telemetry and deployment
•
Aramid core, gum filled
SPECIFICATIONS Receiver Line Cable – 3-pair (A-Unit only) Diameter:
Receiver line cable with molded takeout connector
OD 8.38 mm (0.33 in)
Break Strength:
204 kg (450 lb)
Weight:
7.16 kg (15.79 lb) per 100 m
Standard Takeout Intervals:
30 m, 55 m, 80 m
Other options available upon request
Receiver Line Cable – 4-pair Universal (A-Unit or D-Unit)
Fiber optic cross line cables
Diameter:
OD 8.89 mm (0.35 in)
Break Strength:
181 kg (400 lb)
Break Strength:
204 kg (450 lb)
Weight:
2.8 kg (6.17 lb) per 100 m
Weight:
8.00 kg (17.64 lb) per 100 m
PHYSICAL Operating Temperature:
Standard Takeout Intervals:
30 m, 55 m, 80 m
Other options available upon request
-40 °C to +75 °C
Humidity:
0 to 100%
Cross line Cable 9 / 125 micron ruggedized, military grade, harsh environment fiber
Operating Altitude:
optic cable
Up to + 5,500 m
Diameter:
OD 5.50 mm (0.22 in)
Water Depth Rating:
SCORPION
15 m
© 2010 INOVA Geophysical Equipment Ltd. All rights reserved. Information subject to change without notice. Revised December 2010. 1018-040016I
SCORPION recording system
CENTRAL SYSTEM HARDWARE CRS
FEATURES & SPECIFICATIONS CRS (Central Recording System) •
Shock protected for off-road vehicle or heli-portable operations
•
Two ruggedized PCs are mounted in the enclosure
•
Graphical User Interface (GUI) * 64-bit multi-processor PC * Runs all Windows®-based applications * RAID level 5 disk storage * Multi-monitor video support * Microsoft® Windows® Server 2003
•
Real-Time Engine (RTE) * 64-bit multi-processor PC
TIP
* Field Electronics Interface (FEI) * Seismic Data Processor (SDP) * Maximum output record length 64 sec @ 2 ms
TIM
TIM (Truck Interface Module) •
Truck Network Switch
•
Advanced network packet telemetry
•
Provides connectivity between CRS and TIP (Truck Interface Panel)
•
Provides master clock and source timing
Input Voltage:
•
Source controller hardware interface (12 volt power supplied)
•
Six integrated Delta Sigma analog auxiliary channels
* RAID level 5 disk storage * Gigabit Ethernet ports * Linux™ Operating System
110-240 VAC, 50/60 Hz
Power Consumption
Input Voltage:
< 1000 W with standard equipment
110-240 VAC, 50/60 Hz
Operating Temperature:
Power Consumption
+5 ˚C to +40 ˚C
< 220 W with Source Controller
Storage Temperature:
Operating Temperature:
-40 ˚C to +75 ˚C
+5 ˚C to +40 ˚C
Humidity:
Storage Temperature:
20% - 80% non-condensing
Total CRS Dimensions:
73 cm x 53.3 cm x 49 cm (28.7” x 21” x 19.3”)
Total CRS Weight:
71.4 kg (157.0 lb) (without tape drive module)
-40 ˚C to +75 ˚C
Humidity:
20% - 80% non-condensing
Total TIM Dimensions:
15.3 cm x 394 cm x 41.9 cm (6” x 15.5” 16.5”)
Total TIM Weight:
SCORPION
12.3 kg (27.0 lb)
© 2010 INOVA Geophysical Equipment Ltd. All rights reserved. Information subject to change without notice. Revised December 2010. 1018-040016I
Corporate Headquarters 12200 Parc Crest Drive Stafford, TX 77477 p +1.281.552.3800 f +1.281.552.3811 www.inovageo.com
CENTRAL SYSTEM HARDWARE TIP (Truck Input Panel)
Plotter
•
Provides physical interface between the TIM and the XLUs
•
•
Includes four cross line ports
•
Support up to 120 active lines
ISYS V12 with Ethernet Interface
Dimensions:
43.2 cm x 31.8 cm 15.2 cm (17” x 12.5” x 6”)
Dimensions:
4 cm x 38.8 cm x 38.8 cm (1.6” x 15.3” x 15.3”)
Weight:
11.34 kg (25.0 lb)
Weight:
4.3 kg (9.5 lb)
Tape Drive Options •
Monitors (3 standard with system) •
Standard: 20” fl at screen, 1600 x 1200 resolution
•
Optional: 18” fl at screen, 1600 x 1200 resolution
* Includes dual LTO-2 drives •
Dimensions: 44.4 cm x 19.3 cm x 63.5 cm (17.5” x 7.6” x 25”)
SCSI LVD Kit, P/N 0017-000013 * Supports external dual; LTO-2, LTO-3, 3580
•
Scorpion Internal Tape Drive, P/N 0017-000012
SCSI HVD Kit, P/N 0017-000014 * Supports external dual; 3490, 3590
•
Fiber Channel Kit, P/N 0017-000015 * Supports external dual 3592 (P/N 0014-040027)
Weight:
5.22 kg (11.5 lb)
Printer •
Standard: HP DeskJetTM series
Dimensions:
57.4 cm x 40.9 cm x 18.6 cm (22.6” x 16.1” x 7.33”)
Weight:
6.44 kg (14.2 lbs)
SCORPION
© 2010 INOVA Geophysical Equipment Ltd. All rights reserved. Information subject to change without notice. Revised December 2010. 1018-040016I
SCORPION recording system
SOFTWARE SEISMIC PROJECT MANAGEMENT SOFTWARE • •
•
represent source and receiver status
Daily acquisition plans can be created with a few mouse clicks Efficient management of targeted source points are enabled by the
•
Spread management via map views and context sensitive menus allow easy interaction with the ground equipment
ShotManager display •
Color-coded icons in schematic and on spatially correct map view
•
SourceAware™ QC:
Ground equipment issues reported by the intelligent units are displayed in a separate window (SpreadManager) and indicated on
* Automatically alerts operator about out-of-specification
the map views for easy identification of issue
conditions before the shot occurs based on user-defined
•
thresholds
Embedded spreadsheets with advanced sorting and filtering options:
* Records actual sensor and source quality attribute data to the shot report
* Fast, dynamic identification of available shot points based
* Unit status • Power state
•
Voltage status
on current spread status
•
Telemetry status
•
Source QC based on post-shot or post-sweep information
•
Software revision
•
Integrated INOVA source controller software
•
Serial number
•
Advanced acquisition techniques:
* Unit unsolicited messages
* Source Driven™ acquisition
* Instrument test results
* Interleaved fleets
* Alternating fleets
•
Extensive pre-processing options:
* Receiver test results •
Test results are color coded on spreadsheets and on map views based on user-defined thresholds
•
* Noise edit with burst mode
Information in built-in spreadsheet can easily be filtered or sorted based on user parameters
* Diversity and vertical stack * Correlation before or after stack (zero-phase FFT) •
Cascaded / phase-rotated sweeps and stored pilot
•
Various map underlay options (JPEG, TIFF, Geo-TIFF, etc.) allow the loading of satellite photos, topographic maps or exclusion zone
•
Customizable reports that can also be exported in MS Excel format
•
Real-time spread noise and seismic energy monitoring
•
SPS import and export and center of gravity (CoG) report
•
Windows arrangement can be saved for each user so no time is wasted on arranging windows every day or every shift
information
SCORPION
© 2010 INOVA Geophysical Equipment Ltd. All rights reserved. Information subject to change without notice. Revised December 2010. 1018-040016I
Corporate Headquarters 12200 Parc Crest Drive Stafford, TX 77477 p +1.281.552.3800 f +1.281.552.3811 www.inovageo.com
SOFTWARE
QUALITY CONTROL SOFTWARE
•
Intuitive gain adjustment options
•
•
Embedded Automatic Gain Control (AGC) and True Amplitude
The Scorpion QC software, also known as the Plotter software, is
Recovery (TAR) algorithms
often complimented by clients for it’s ease of use The application can also be executed as a stand-alone program
•
RMS Noise Analysis
on practically any computer which allows easy off-site analysis of
•
Spectral Analysis – Phase and Amplitude
SEGY data files produced by the Scorpion system.
•
Tape read – SEGY, SEGD
•
Noise Edit
•
Disk read (volume of file) – SEGY, SEGD
•
Various filtering options:
•
Save trace display as Image (Jpeg or Bitmap)
* Band pass filter
•
Print traces to standard printer or plot to thermal plotter
* Low Cut filter
•
Automatic Display configuration synchronization with the
•
Scorpion seismic project management application
* Notch filter •
SVSM Spectral Shaping Filter
•
Trace Sorting (by Line, Station or Component Type)
•
Spread Energy display above the trace display helps identify
•
Vibrator hardwire similarity analysis
problems with channels
•
Create SEG-Y files of selected and sorted traces with lower
Interpreted SEG-Y header display available by right-clicking on
•
Read SEG-D or SEG-Y files from disk (File or Volume)
the wiggle trace or iterating through the traces with navigation
•
Optional Zero Data indication on trace display
buttons
•
Optional First Break Estimation on trace display
SEG-Y data display in floating point values
•
Spectral Analysis can stack selected region prior to analysis
•
•
SCORPION
© 2010 INOVA Geophysical Equipment Ltd. All rights reserved. Information subject to change without notice. Revised December 2010. 1018-040016I
SCORPION recording system
TEST EQUIPMENT HDU (HANDHELD DEPLOYMENT UNIT) FEATURES •
Ultra rugged and lightweight
•
Easy to use, Windows Mobile user interface
•
Full instrument tests on both A-Units and D-Units
•
Support for receiver tests
•
Telemetry test capability
•
Power distribution test via BBU serial port
•
XLU fiber optic cable test support
•
DataBridge deployment and test interface
SPECIFICATIONS Operating System:
Windows Mobile
Volatile Memory:
64 MB SDRAM
Non-volatile Memory:
Up to 1 GB
Display:
240 x 320 pixel (¼ VGA) color TFT with LED front light
PHYSICAL Size:
16.5 cm × 9.5 cm × 4.5 cm (6.5” x 3.75” x 1.75”)
excluding splash proof case
Weight:
Less than 0.49 kg (1.1 lb) excluding splash proof case and cable
Operating Temperature:
-30 ˚C to +60 ˚C
Storage Temperature:
-40 ˚C to +70 ˚C
Water Depth:
SCORPION
Sealed against accidental immersion. (1 m for 30 min)
© 2010 INOVA Geophysical Equipment Ltd. All rights reserved. Information subject to change without notice. Revised December 2010. 1018-040016I
Corporate Headquarters 12200 Parc Crest Drive Stafford, TX 77477 p +1.281.552.3800 f +1.281.552.3811 www.inovageo.com
TEST EQUIPMENT RTS (REMOTE TEST STATION) FEATURES •
Tests to isolate failures and confirm successful repairs on
20” Flat panel monitor
individual ground electronics units •
Power consumption evaluation
•
Weight:
•
Telemetry functionality evaluation
•
Dimensions: 63.5 cm x 44.5 cm x 19.3 cm (25” x 17.5” x 7.6”)
•
Analog Built-in Tests (BITs) to confirm A-Unit integrity and compliance to specification
• •
5.22 kg (11.5 lbs)
TIU (Test Interface Unit)
Digital tests to confirm D-Unit and VectorSeis receiver integrity
•
Weight:
Ability to connect ground electronics units in a mock
•
Dimensions: 19.7 cm x 21.0 cm x 30.5 cm (7.75” x 8.25” x 12”)
5.44 kg (12 lbs)
spread setup •
Consists of a desktop PC, monitor, interface unit, two power supplies, a keyboard and a mouse
Power supply - Xantrex XHR 60-18
SPECIFICATIONS
•
Weight:
Desktop PC running Microsoft® Windows® XP Professional
•
Dimensions: 8.7 cm x 21.5 cm x 47.2 cm (3.43” x 8.45” x 18.59”)
•
Weight:
RTS
•
Dimensions: 45.2 cm x 18.7 cm x 46.1 cm
15.42 kg (34 lbs) (17.80” x 7.38” x 18.13”)
SCORPION
6.4 kg (14 lbs)
•
Operating Temperature: +5 ˚C to +40 ˚C
•
Storage Temperature:
-40 ˚C to +75 ˚C
•
Humidity:
20% - 80% non-condensing
© 2010 INOVA Geophysical Equipment Ltd. All rights reserved. Information subject to change without notice. Revised December 2010. 1018-040016I