Preview only show first 10 pages with watermark. For full document please download

Scroll Chiller

   EMBED


Share

Transcript

SCROLL CHILLER Modular Air-cooled Scroll Chiller It is a kind of air-cooled scroll chiller that can be connected to all sorts of fan coil unit to realize cooling/heating for civil or industrial buildings. D Series Display panel Golden fin condenser Z26301C 130/160kW 65/80kW Inner groove copper Modular structure Comprehensive protection Self-diagnosis Easier maintainability Memory function Easier maintainability 24 hour timer Running condition real-time display. Low start-up current thanks to power delay control design. Unique compressor alternation operation technology largely prolong the lifespan of compressor. Double-flow design makes a higher heat exchange efficiency. Special top cover design: make a better cooling capacity of 5% improvement and higher heat exchanging efficiency of 3% improvement. Main module patent: any unit can be set as main module via wired controller. Up to 16 units (60/71kW) or 8 units (120/145kW) can be integrated freely to get a max capacity of 1160kW thanks to modular design. Auto anti-freezing function under heating mode when the unit is switched off. Water side (water temperature) Item Nominal operating condition Air side (outdoor temperature) Operating range Nominal operating condition Operating range Cooling Inlet(«) 12 Outlet(«) 7 Outlet(«) 5~15 I/O difference(«) 2.5~6 DB(«) 35 WB(«) - DB(«) 15~45 Heating 40 45 40~50 2.5~6 7 6 -15~24  COMMERCIAL AIR CONDITIONERS Model Heat pump Capacity Cooling/Heating Capacity steps EER/COP Power supply Power input Compressor Cooling Heating Type Starting mode Quantity Type Water side heat exchanger Air side heat exchanger 7ATERÒ¹OWÒVOLUME Pressure drop Connection pipe Type Fan type and quantity 4OTALÒFANÒAIRÒ¹OW Net/Gross/Operating weight Loading quantity 40'GP/40'HQ % W/W Ph/V/Hz kW kW - - - - L/s GPM kPa ft.WG - - - L/s CFM kW dB(A) mm mm kg set LSQWRF65M/NaD-M 60/65 17.0/18.5 0-50-100 2.84/3.09 3/380-415/50 21.1 21.0 Hermetic scroll Direct starting 2 2.9 45.0 15 4.9 DN65 axial×2 LSQWRF80M/NaD-M 71/79.5 20.2/22.6 0-50-100 LSQWRF130M/NaD-M 120/130 34.1/37.0 0-25-50-75-100 2.76/2.94 2.84/2.93 3/380-415/50 3/380-415/50 42.3 25.7 44.4 27.0 Hermetic scroll Hermetic scroll Direct starting Direct starting 4 2 (IGH EFµCIENTÒÒSHELLÒANDÒTUBEÒHEATÒEXCHANGER 5.7 3.4 91.0 54.0 30 20 9.8 6.6 DN80 DN65 (IGH EFµCIENTÒµNÒTUBEÒTYPEÒHEATÒEXCHANGER axial×4 axial×2 LSQWRF160M/NaD-M 145/170 41.2/48.3 0-25-50-75-100 2.74/3.04 3/380-415/50 53.0 56.0 Hermetic scroll Direct starting 4 6.9 110.0 35 11.5 DN80 axial×4 0.75×104 1.59×104 0.65×2 70 2040×1000×2230 2120×1080×2230 0.83×104 1.76×104 0.95×2 71 2040×1000×2230 2120×1080×2230 1.5×104 3.18×104 0.65×4 72 2226×1650×2230 2306×1730×2230 1.67×104 3.53×104 0.95×4 74 2226×1650×2230 2306×1730×2230 710/715/781 10/10 760/765/836 10/10 1256/1261/1382 6/6 1440/1445/1584 6/6 SCROLL CHILLER Total fan motor power Sound pressure level Outline(W×D×H) Dimension Package(W×D×H) kW RT Note: The specification is tested under the connection pipe of 7.5 meters.  COMMERCIAL AIR CONDITIONERS