Preview only show first 10 pages with watermark. For full document please download

Sealed Lead-acid Battery

   EMBED


Share

Transcript

UPG No. 45969 Sealed Lead-Acid Battery Absorbant Glass Mat (AGM) technology for superior performance. Valve regulated, spill proof construction performance. Valve regulated, spill proof construction allows safe operation in any position. Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certified. U.L. r ecognized under file number MH. 6V200 Maintenance-Free Specification Nominal Voltage Nominal Capacity 20-hr. (0.75A to 10.50 volts) Approximate Weight Terminal - Connector Insert Max Discharge Current for 5 sec. (A) Max Charge Current (A) Ambient Temperature Charge Discharge Storage Expected Life for Standby Use at 20°C Case Self-Discharge Characteristics (25°C) Aging Time Residual Capacity Effect of Temperature on Capacity (20hr) Temperature Dependency of Capacity (20hr) 6 volts (3 cells) 200AH 60.62 lbs (27.5 kgs) M6.0 2000 A 70 A 0°C (32°F) to 40°C (104°F) -20°C (-4°F) to 50°C (122°F) -20°C (-4°F) to 40°C (104°F) 1-3 Years ABS Plastic 3 Months 91% 6 Months 82% 12 Months 64% 40°C 102% 25°C 100% 0°C 85% -15°C 65% Physical Dimensions: in (mm) Terminals L: 12.05 in (306 mm) W: 6.61 in (168 mm) H: 8.66 in (220 mm) TH: 8.86in (225 mm) Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for height dimensions. All data subject to change without notice. Charge Current & Final Discharge Voltage Application Charge Voltage(V/Cell) Set Point Allowable Range Cycle Use Temperature 25 (77 ) 2.45 2.40~2.50 Standby 25 (77 ) 2.325 2.30~2.35 Max.Charge Current Final Discharge Voltage V/Cell 1.75 1.70 1.60 1.30 0.35C Discharge Current(A) 0.2C>(A) 0.2C<(A)<0.5C 0.5C<(A)<1.0C (A)>1.0C www.upgi.com 1720 Hayden Drive Carrollton, Texas 75006 VR080111 P 469.892.1122 T 866.892.1122 F 469.892.1123 [email protected] UPG No. 45969 6V200 Maintenance-Free Battery Dischanging Current VS Dischanging Time Cell voltage ( V/Cell ) Battery Discharge Characteristics ( Minute ) ( Hour ) Discharge time Battery Charging Characteristics for Cyclic Use Battery Charging Characteristics for Standby Use Battery Charging Characteristics for Standby Use 1 Discharge 100 % (0.1CA*10h) -- 50 % (0.1CA*5h) 2 Constant voltage charging Charge voltage : 2.45V/cell Charge current : 0.3CA 3 Temperature : 25 (77 ) Charge current (CA) Charge volume Cell charge voltage ( V/Cell ) Cell charge voltage Charge volume (%) Cell charge voltage ( V/Cell ) Charge current (CA) Charge volume (%) Cell charge voltage Charge volume 1 Discharge 100 % (0.1CA*10h) --50 % (0.1CA*5h) 2 Constant voltage charging Charge voltage : 2.275V/cell Charge current : 0.1CA (77 ) 3 Temperature : 25 Charge current Charge current Charge Time (hr) Charge Time (hr) Let UPG Power Your Life. www.upgi.com 1720 Hayden Drive Carrollton, Texas 75006 P 469.892.1122 T 866.892.1122 F 469.892.1123 [email protected]