Preview only show first 10 pages with watermark. For full document please download

Section 1

   EMBED


Share

Transcript

11 Introduction Introduction The Purpose of This Quick–start manual will show a person the basics of getting started using this Supplementary DirectSOFT32 without referring to the DirectSOFT32 Programming Software Users Manual. This manual is not intended to replace reading the Manual DirectSOFT32 Programming Software Users Manual. This manual is a supplement to those who may not be familiar with similar PLC programming software. If you have a PLC belonging to the DirectLOGIC CPU family, you can use Who Can and DirectSOFT to create your ladder logic programs. The families of PLCs (DL05, Should Use DL06, DL105, DL205, DL305 and DL405) that currently exist under this description DirectSOFT32? are shown below. The DirectSOFT32 Programming Software Users Manual details all of the programming tools made available to the user. Besides being easy to use, DirectSOFT32 version 4.0 includes the following features: D set up a DV1000 Data Access Unit D tune PID loops for the DL05, DL06, D2–250–1, D3–350, and D4–450 D set up the parameters for Drum Sequencers in the DL05, DL06, DL105, D2–250–1, D3–350, and D4–450 DirectSOFT will also work with many DirectLOGIC compatible products (not shown in the diagram). If you fall into this category, however, the chart on the next page shows you a complete list of which products work with the software. Diagram Showing the Basic System Compatibility Your computer with DirectSOFT installed DL405 & DCM DL305 & DCU DL205 CPUs DL06 G 0VC0 Y0 Y2 C1 Y5 Y7 Y10 Y12 C3 Y15 Y17 A C (G L)A C (L N )24V Y1 Y3 Y4 Y6 C2 Y11 Y13 Y14 Y16 N .C . OUTPUT: 6–240V 40VA INPUT: 3 – 12 15mA – 24V 50–60Hz DL405 CPUs C0 X1 XC1 X 3X 4XC2 6X11 X13 X14 C4 XX22 X23 21 N . X0 X2X5 X10 7X12 C3 XX16 X17 15 X20 N .C ..C PORT1PORT2 Excellent choice if bottom Two or three built-in port on DL405 is already being used ports Allows higher Max. baud= 19.2K performance with rates up to 38.4K baud DV-1000 Data Access Unit Can be used with any PLC belonging to the DL05, DL105, DL205 or DL405 families. Using DirectSOFT greatly simplifies setup. DL450 Setup for Drum Sequencer and PID Loops Allows higher performance with rates up to 38.4K baud Use an RS422 DCU if multi-drop and a third port is required. Maximum baud rate= 19.2K DL340 CPU Two built-in ports Requires RS232/422 converter if multi-drop Max. baud = 38.4K DirectSOFT32 Programming Software Quick–start Manual, 5th Edition, 8/02 Built-in ports. Requires RS232/422 converter if multi-drop Max. baud= 38.4K DL05 Two Built-in Ports Max. baud= 9.6K Setup for Drum Sequencer Two Built-in Ports PID loops Baud rates up to 38.4K baud DL105 One Built-in Port Max. baud= 9.6K Setup for Drum Sequencer 2 Introduction PLC Compatibility Family CPU DirectSOFT Programming DirectSOFT Programming Single Family PC–PGMSW DirectSOFT Site Licenses DirectSOFT OEM License DirectSOFT DSData Server DL05 Requires Rel. 2.4a or later 3 PC–PGM105 or PC–PGM–BRICK 3 3 DL06 Requires Rel. 4.0 or later 3 PC–PGM–BRICK 3 3 DL105 F1–130** (requires Rel. 2.4a or later) 3 PC–PGM105 or PC–PGM–BRICK 3 3 DL205 D2–230 3 PC–PGM205 3 PC–D2OEM 3 D2–240 3 PC–PGM205 3 PC–D2OEM 3 D2–250 (D2–250–1 requires Rel. 4.0 or later) 3 PC–PGM205 3 PC–D2OEM 3 D2–260 (requires Rel. 4.0 or later) 3 PC–PGM205 3 PC–D2OEM 3 D3–330*, D3–330P* 3 PC–PGM–305 3 PC–D3OEM 3 D3–340 3 PC–PGM–305 3 PC–D3OEM 3 D3–350 (requires Rel.2.4a or later) 3 PC–PGM–305 3 PC–D3OEM 3 D4–430 3 3 PC–D4OEM 3 D4–440** 3 3 PC–D4OEM 3 D4–450** (requires Rel 2.4a or later) 3 3 PC–D4OEM 3 IC610CPU105* 3 3 PC–D3OEM 3 IC610CPU106* 3 3 PC–D3OEM 3 325–07*, PPX:325–07* 3 3 PC–D3OEM 3 330–37*, PPX:330–37* 3 3 PC–D3OEM 3 325S–07* (or 325 with Stage Kit) 3 3 PC–D3OEM 3 330S–37*, PPX:330S–37* 3 3 PC–D3OEM 3 335–37, PPX:335–37 3 3 PC–D3OEM 3 425–CPU, PPX:425–CPU ** 3 3 PC–D4OEM 3 PPX:430–CPU 3 3 PC–D4OEM 3 435–CPU, PPX:435–CPU ** 3 3 PC–D4OEM 3 DL305 DL405 GE Series 1 TI305t / SIMATIC TI305t TI305 TI405t/ SIMATIC TI405t TI405 * — requires Data Communications Unit (D3–232–DCU) ** — also DC versions NOTE: In general, the compatible products listed offer similar features and are even identical in some cases. However, DirectSOFT32 has not been completely tested with the compatible products. There may be some aspects of system operation that may not be supported, or, that may not work the same as previous software packages. Supported Devices One of the benefits with the DirectLOGIC family is the wide variety of programming connections. For example, you can use DirectSOFT32 to communicate directly with a PLC or you can use a communications device, such as, the DL405 Data Communications Module. Below is a list of supported devices: Data Communication Devices: D DL405 Data Communications Module (D4–DCM) D DL405 Ethernet Communications Module (H4–ECOM) D DL305 Data Communications Unit (D3–232–DCU, D3–422–DCU) D DL205 Data Communications Module (D2–DCM) D DL205 Ethernet Communications Module (D2–ECOM) I/O Modules: D DL405 Slice I/O Modules D D2–RSSS (Slice protocol) D T1K–RSSS (Slice protocol) DirectSOFT32 Programming Software Quick–start Manual, 5th Edition, 8/02