Preview only show first 10 pages with watermark. For full document please download

Section 1 Intropages

   EMBED


Share

Transcript

PREMIUM CATEGORY 5e CABLE STANDARD COMPLIANCES ANSI/TIA/EIA-568-B.2 (Category 5e) ANSI/TIA/EIA-862 (Building Automation) ISO/IEC 11801 Ed. 2.0 (Class D) ICEA S-90-661 (Category 5e) UL & c(UL) Type CMR (UL 1666) for Non-Plenum UL & c(UL) Type CMP (NFPA 262) for Plenum UL 444 B APPLICATIONS IEEE 802.3: 1000BASE-T (Gigabit Ethernet), 100BASE-TX, 10BASE-T 155 Mp/s, 622 Mp/s ATM ANSI X3.263: 100 Mb/s 4/16 Mb/s Token Ring Broadband and Baseband analog video CONSTRUCTION Conductors • 24 AWG solid bare annealed copper Color Code • Pair 1: Blue-White/Blue • Pair 2: Orange-White/Orange • Pair 3: Green-White/Green • Pair 4: Brown-White/Brown Insulation • Non-Plenum: Polyolefin • Plenum: 3 pairs FEP/ 1 pair Polyolefin Rip Cord • Applied longitudinally under jacket ELECTRICAL CHARACTERISTICS PHYSICAL DATA CMR CMP (Non-Plenum) (Plenum) 0.210 0.190 Nominal Cable Weight (lbs/1000 ft) 22 Minimum Bend Radius (in) Maximum Pulling Force (lbs) Nominal Cable Diameter (in) Temperature Rating (°C) Installation: Operation: 14 Jacket • Non-Plenum: Flame-Retardant PVC • Plenum: Low-Smoke, Flexguard® Flame-Retardant PVC DC Resistance (max) Ohms/100m (328ft) @ 20°C 8.9 DC Resistance Unbalance (max) Individual Pair % 3.0 20 Delay Skew (max) ns/100m 25 1.0 1.0 Nom. Velocity of Propagation % Speed of Light 25 25 Characteristic Impedance Ohms Frequency (f): 1-350 MHz 100 ± 15 0 to +60 -10 to +60 0 to +60 -10 to +60 Input Impedance Frequency (f): 1-100 MHz 100-350 MHz CMP: 72 CMR: 70 Ohms 100 ± 15 100 ± 22 ENHANCED TRA N SM I SSI O N TH RO U G H P U T GenSPEED™ 5500 FEATURES AND BENEFITS Positive PSACR beyond 200MHz for increased available bandwidth Enhanced signal-to-noise ratio improving bit error rate Every master reel is tested for electrical performance compliance TRU-Mark™ print legend contains footage marking from 1000' to 0' Unique product-specific packaging for ease of identification UL Verified for guaranteed performance Application assurance warranty GENSPEED 5500 CABLE CROSS SECTION JACKET INSULATION CONDUCTOR RIP CORD ELECTRICAL PERFORMANCE Frequency MHz 1 4 10 16 20 31.25 62.5 100 155 200 250 300 350 PSACR min. 68.1 57.1 48.9 44.1 41.7 36.4 26.9 19.0 10.3 4.5 – – – ACR min. 70.1 59.1 50.9 46.1 43.7 38.4 28.9 21.0 12.3 6.5 0.8 – – Attenuation PSNEXT max. min. 1.9 68.3 3.9 59.3 6.1 53.3 7.8 50.3 8.8 48.8 11.2 45.9 16.2 41.4 21.0 38.3 26.8 35.5 31.0 33.8 35.3 32.3 39.2 31.2 43.0 30.2 NEXT min. 70.3 61.3 55.3 52.3 50.8 47.9 43.4 40.3 37.5 35.8 34.3 33.2 32.2 PSELFEXT min. 62.0 50.0 42.0 37.9 36.0 32.1 26.1 22.0 18.2 16.0 14.0 12.5 11.1 ELFEXT min. 65.0 53.0 45.0 40.9 39.0 35.1 29.1 25.0 21.2 19.0 17.0 15.5 14.1 Return Loss min. 20.0 23.0 25.0 25.0 25.0 23.6 21.5 20.1 18.8 18.0 17.3 16.8 16.3 Note: Values are expressed in dB per 100m (328ft.) length. PART NUMBERS Standard packaging: 1000' Pull-Pac® ll Pull-Pac® ll Jacket Color Blue White Yellow Gray Red Orange Green Black Pink Purple CMR (Non-Plenum) 6133299 6133255 6133289 6133200 6133274 6133746 6133512 6133696 6133290 6133445 CMP (Plenum) 6131278 6131361 6131546 6131418 6131477 6131422 6131547 6131683 6131709 6131730 Spool-Pac® CMR (Non-Plenum) 6133403 6133339 6133369 6133331 6133383 6133615 6133447 6133446 CMP (Plenum) 6131433 6131449 6131379 6131619 6131635 6131576 6131575 6131478 Spool CMR CMP (Non-Plenum) (Plenum) 6131282 6133492 6131618 6133348 6133334 6133616 6133341 Note: Bulk reels are available as a special request with a maximum allowable length of 3000 feet per reel. Part number for a bulk reel is the corresponding spool part number with a .99 suffix. Minimum run and lead-time may apply. Data subject to change without notice. 15