Preview only show first 10 pages with watermark. For full document please download

Section 20 - Schneider Electric

   EMBED


Share

Transcript

Table of Contents Section 20 Electronic Sensors and Machine Cabling Osiconcept™ Sensors—Osiris® Photoelectric Sensors Photoelectric Sensors, p. 20-2 New! New! New! 20-2 Miniature XUM 20-3 Compact XUK and XUX 20-3 Dual-Mount XUN 20-3 Osiconcept™ Sensors—Osiprox® Proximity Sensors Plastic Rectangular 20-4 Plastic Tubular 20-5 Basic Series 20-6 Food and Beverage 20-7 VMI 20-8 VMI18 20-8 SM300 20-8 Ultrasonic Sensors Proximity Sensors, p. 20-4 Ultrasonic Sensors, p. 20-8 Tubular XUB SM600 20-8 Virtu® 30 20-9 SM900 ( 1 m and 2 m) 20-9 SM900 (8 m) 20-9 Ositrack® RFID 20-10 20 ELECTRONIC SENSORS AND MACHINE CABLING Radio Frequency Identification © 2007 Schneider Electric All Rights Reserved 20-1 Osiris® Photoelectric Sensors XUB Tubular Refer to Catalog 9006CT0101 www.us.schneider-electric.com FOR CURRENT INFORMATION Diffuse Background suppression Polarized retroreflective A single product that automatically adapts to most environments. Programmable N.O. / N.C. N.O.: object present = output On N.C.: no object present = output On Thru-beam Usable sensing distance XUB XUB 18 plastic 18 metal 0.6 m (1.9’) 0.6 m (1.9’) 2 m (6.6’) 2 m (6.6’) 4 m (13.1’) 4 m (13.1’) 15 m (49’) 15 m (49’) M18 x 1 M18 x 1 P / M18 x 46 P / M18 x 46 — — Temperature range: –25 to +55 °C (-13 to +131 °F) Degree of protection (conforming to IEC 60529): IP65, IP67 (XUK: IP65) Proximity diffuse Polarized retro-reflective Retro-reflective Thru-beam Mounting (mm) Case M (metal), P (plastic) / Dimensions (mm) Ø x L or W x H x D Setup LEDs Common characteristics Sensors for DC applications (solid-state output: transistor) Pre-cabled, PvR, L + (2 m) M12 connector Pre-cabled, PvR, L + (2 m) M12 connector Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price Transmitter XUB2AKSNL2T 36.00 XUB2AKSNM12T 41.00 XUB2AKSNL2T 36.00 XUB2AKSNM12T 41.00 Proximity diffuse, adjustable N.O. XUB5APANL2 62.00 XUB5APANM12 70.00 XUB5BPANL2 62.00 XUB5BPANM12 78.00 N.C. XUB5APBNL2 62.00 XUB5APBNM12 70.00 XUB5BPBNL2 62.00 XUB5BPBNM12 78.00 Polarized retro-reflective N.O. XUB9APANL2 62.00 XUB9APANM12 70.00 XUB9BPANL2 69.00 XUB9BPANM12 78.00 Receiver or N.C. XUB9APBNL2 62.00 XUB9APBN12 70.00 XUB9BPANL2 69.00 XUB9BPANM12 78.00 Transmitter/Receiver, Retro-reflective N.O. XUB1APANL2 52.00 XUB1APANM12 59.00 XUB1BPANL2 58.00 XUB1BPANM12 66.00 3-wire PNP a N.C. XUB1APBNL2 52.00 XUB1APBN12 59.00 XUB1BPANL2 58.00 XUB1BPANM12 66.00 Thru-beam N.O. XUB2APANL2R 40.00 XUB2APANM12R 46.00 XUB2BPANL2R 45.00 XUB2BPANM12R 51.00 N.C. XUB2APBNL2R 40.00 XUB2APBN12R 46.00 XUB2BPANL2R 45.00 XUB2BPANM12R 51.00 Supply voltage limits, min/max (V) including ripple 10–36 10–36 10–36 10–36 Switching frequency (Hz) 500 500 500 500 Common characteristics for DC versions Switching capacity, max (mA): 100 / Overload and short-circuit protection / LED output state Multi-current/multi-voltage sensors for AC/DC applications (10–36 Vdc / 20–264 Vac including ripple on DC [relay output, 1 C/O, 3 A]) Connection — — — Transmitter — — — Diffuse N.O + N.C. — — — Also available in Design 18 metal, 2-wire type Polarized reflex N.O + N.C. — — — Receiver or multi-current/multi-voltage Transmitter/Receiver Reflex N.O + N.C. — — — AC/DC. Refer to Thru-beam N.O + N.C. — — — www.SESensors.com. Switching frequency (Hz) — — — LED output state indicator( ) / power on LED ( ) — — — a For version with NPN output, replace “P” with “N”. For example: XUB1APANL2 would become XUB1ANANL2. Connection Accessories Table 20.1: Reflectors Catalog $ Price No. mm 24 x 21 XUZC24 Ø 80 XUZC80 50 x 50 XUZC50 3.20 9.60 4.80 Table 20.3: Connectors 90° Straight Snap-Ca Suitable plug-in female connectors, including pre-wired versions 20 2 m long without LED XUZC24 ELECTRONIC SENSORS AND MACHINE CABLING Table 20.2: XUZC80 M12 Mounting Brackets Mounting Brackets for XUB 20-2 M8 XUZC50 Catalog No. $ Price Stainless Steel XUZA118 5.60 Plastic XUZA218 8.30 DS2 Discount Schedule Modified 4/17/09 b Catalog No. XSZCS151 XSZCS141 N/A $ Price 17.00 15.00 Catalog No. XSZCD111 XSZCD101 XZCC12FDM40V $ Price 14.00 14.00 9.00 This new, innovative connector is universal, simple, and quick to use. For all Telemecanique brand sensors with Snap-C compatible M12 connectors (pointed pins): — create cabling to the required length without using a screwdriver or soldering iron. — ready in just a few seconds with no stripping required. © 2007 Schneider Electric All Rights Reserved www.us.schneider-electric.com Osiris® Photoelectric Sensors XUM Miniature, XUK and XUX Compact Refer to Catalog 9006CT0101 FOR CURRENT INFORMATION Diffuse A single product that automatically adapts to most environments. Background suppression Programmable N.O. / N.C. N.O.: object present = output On N.C.: no object present = output On Polarized retroreflective Thru-beam Proximity diffuse Polarized retroreflective Retroreflective Thru-beam Mounting (mm) Case M (metal) P (plastic) / Dimensions (mm) Ø x L or W x H x D Setup LEDs Common characteristics Sensors for DC applications (solid-state output: transistor) P / 12 x 34 x 27 Connection Pre-cabled, PvR, L=2 m XUM2AKSNL2T 43.00 XUM5APANL2 80.00 XUM5APBNL2 80.00 XUM9APANL2 80.00 XUM9APBNL2 80.00 XUM1APANL2 67.00 XUM1APBNL2 67.00 XUM2APANL2R 51.00 XUM2APBNL2R 51.00 10–30 500 P / 18 x 50 x 50 XUX Compact Design 2.1 m (7.9’) 11 m (36’) 14 m (46’’) 40 m (131.2”) direct: mounting centers 30/36 to 40/50/74, M5 screws P / 30 x 92 x 71 LED output state indicator and power on LED ( PhotoVirtu 0.1 m (0.3’) / 0.6 m (2’) 2 m (6.56’) — 15 m (49.21) M18 x 1 or direct centers 24.1, M3 screws P / 65 x 44 x18 ): yes Catalog No. $ Price Transmitter Proximity diffuse, adjustable b Polarized retroreflective Receiver or Transmitter/ Receiver, 3-wire PNP a XUK Compact Design 50 x 50 1 m (3.2’) DC or AC 5 m (16.4’) DC or 4 m (13.1’)AC 9 m (29.5’) DC or 17 M (22.4’) AC 30 m (98’) DC or 20 m (65.6’) AC direct: mounting centers 40 x 40, M4 screws N.O. N.C. N.O. N.C. Retroreflective N.O. N.C. Thru-beam N.O. N.C. Supply voltage limits, min/max (V) including ripple Switching frequency (Hz) Common characteristics for DC versions Pre-cabled, PvR, M12 connector Screw trmls, ISO 16 L=2 m chi.gland XUM2AKSNM8T XUK2AKSNL2T XUK2AKSNM12T XUX0AKSAT16T 49.00 35.00 40.00 41.00 XUM5APANM8 XUK5APANL2 XUK5APANM12 XUX5APANT16 90.00 70.00 80.00 100.00 XUM5APBNM8 XUK5APBNL2 XUK5APBNM12 XUX5APBNT16 90.00 70.00 80.00 100.00 XUM9APANM8 XUK9APANL2 XUK9APANM12 XUX9APANT16 90.00 75.00 85.00 107.00 XUM9APBNM8 XUK9APBNL2 XUK9APBNM12 XUX9APBNT16 90.00 75.00 85.00 107.00 XUM1APANM8 XUK1APANL2 XUK1APANM12 XUX1APANT16 77.00 63.00 72.00 90.00 XUM1APBNM8 XUK1APBNL2 XUK1APBNM12 XUX1APBNT16 77.00 63.00 72.00 90.00 XUM2APANM8R XUK2APANL2R XUK2APANM12R XUX2APANT16R 58.00 54.00 61.00 75.00 XUM2APBNM8R XUK2APBNL2R XUK2APBNM12R XUX2APBNT16R 58.00 54.00 61.00 75.00 10–30 10–30 10–30 10–36 500 500 500 500 indicator ( ): yes / power on LED ( ): yes M8 connector Multi-current/multi-voltage sensors for AC/DC applications, 10–36 Vdc / 20–264 Vac including ripple on DC (relay output, 1 C/O, 3 A) Pre-cabled, Screw trmls, ISO 16 Connection — — — L=2 m chi.gland XUX0ARCTT16T XUK2ARCNL2T — Transmitter — — 43.00 68.00 XUK5ARCNL2 XUX5ARCNT16 Diffuse N.O + N.C. — — — 83.00 96.00 XUK9ARCNL2 XUX9ARCNT16 Polarized retroreflective N.O + N.C. — — — Receiver or T/R, 90.00 104.00 Transmitter/ XUK1ARCNL2 XUX1ARCNT16 Receiver Retroreflective N.O + N.C. — — — 75.00 87.00 XUK2ARCNL2R XUX2ARCNT16R Thru-beam N.O + N.C. — — — 64.00 72.00 Switching frequency (Hz) — — 20 — 20 LED output state indicator( ) / power on LED ( ) — — / — / a For version with NPN output, replace “P” with “N”. For example: XUB1APANL2 would become XUB1ANANL2. b XUN models are not adjustable. c For versions with 0.06 m (2”) sensing distance, replace “4” with “5”. For example: XUN4APANM123 would become XUN5APANM12. M12 connector M12 connector XUX0AKSAM12T 49.00 XUX5APANM12 89.00 XUX5APBNM12 89.00 XUX9APANM12 95.00 XUX9APBNM12 95.00 XUX1APANM12 81.00 XUX1APBNM12 81.00 XUX2APANM12R 68.00 XUX2APBNM12R 68.00 10–36 500 XUN0AKSNM12T 89.00 XUN4APANM12 c 79.00 XUN4APBNM12 c 79.00 XUN9APANM12 79.00 XUN9APBNM12 79.00 — — — — — — — — — — — — — — — — — — XUN0APSNM12 89.00 XUN0ANSNM12 89.00 10–36 500 ELECTRONIC SENSORS AND MACHINE CABLING Usable sensing distance XUM Miniature Design 0.4 m (1.3') 2 m (78.74”) 4 m (13.1) 8 m (26.2’) direct: mounting centers 25.5, M3 screws 20 NOTE: M8 is not Snap-C compatible. See page 20-2 for suitable plug-in female connectors, including pre-wired versions. © 2007 Schneider Electric All Rights Reserved DS2 Discount Schedule 20-3 Osiprox® Proximity Sensors XS Plastic Rectangular Refer to Catalog 9006CT0101 www.us.schneider-electric.com FOR CURRENT INFORMATION New! non-flush mountable in metal flush mountable in metal A single product that automatically adapts to most environments. Accurate position detection via teach mode. Type E (26 x 26 mm) Nominal Sensing Distance Usable sensing distance S (mm) shielded/non-shielded Precision adjustment range (mm) shielded/non-shielded Mounting in metal Enclosure M (metal) P (plastic) Temperature range oF (oC) Degree of protection (conforming to IEC 60 529) Sensors for DC applications (3-wire) 3-wire Dimensions (mm) H x W x L PNP PNP NPN NPN PNP PNP NPN NPN Supply voltage limits min/max (V) including ripple Switching capacity, max (mA) Short-circuit protection LED output state indication / power on LED Voltage drop, closed state (V) at I nominal Switching frequency (Hz) Sensors for AC or DC applications (2-wire) 3-wire Dimensions (mm) H x W x L AC/DC without 2-wire short-circuit protection d N.O. N.C. N.O. N.C. N.O. N.C. N.O. N.C. N.O. N.C. N.O. AC/DC without short-circuit protection d N.C. Supply voltage limits min/max (V), including ripple on DC Switching capacity, max (mA) LED output state indication / power on LED Residual current, open state (mA) Voltage drop, closed state (V) at I nominal Switching frequency (Hz), AC / DC 2-wire $ Price Connection: pre-cabled PvR (2 m) 26 x 26 x 13 XS8E1A1PAL2 80.00 XS8E1A1PBL2 80.00 XS8E1A1NAL2 80.00 XS8E1A1NBL2 80.00 Connection: M8 or M12 connector XS8E1A1PAM8 91.00 XS8E1A1PBM8 91.00 XS8E1A1NAM8 91.00 XS8E1A1NBM8 91.00 10–36 100 yes yes / yes <2 1000 Type D (80 x 80 mm) 60 mm 0–40 / 0–60 20–40 / 20–60 P –13 to 158 (–25 to 70) P –13 to 158 (–25 to 70) 40 x 40 x 15 XS8C1A1PAL2 XS8C1A1PBL2 XS8C1A1NAL2 XS8C1A1NBL2 XS8C1A1PAM8 XS8C1A1PBM8 XS8C1A1NAM8 XS8C1A1NBM8 10–36 200 yes yes / yes <2 1000 80 x 80 x 26 XS8D1A1PAL2 XS8D1A1PBL2 XS8D1A1NAL2 XS8D1A1NBL2 90.00 90.00 90.00 90.00 103.00 90.00 103.00 103.00 XS8D1A1PAM12 XS8D1A1PBM12 XS8D1A1NAM12 XS8D1A1NBM12 10–36 200 yes yes / yes <2 100 80 x 80 x 26 XS8D1A1MAL2 XS8D1A1MBL2 98.00 98.00 112.00 112.00 XS8D1A1MAU20 XS8D1A1MBU20 20–264 300 yes / yes < 1.5 < 5.5 50 / 1000 $ Price 120.00 120.00 120.00 120.00 138.00 138.00 138.00 138.00 149.00 149.00 149.00 149.00 Accessories For flat sensors, Forms E, C and D 20 ELECTRONIC SENSORS AND MACHINE CABLING DS2 $ Price 25 mm 0–15 / 0–25 8–15 / 8–25 Connection: pre-cabled PvR (2 m) 26 x 26 x 13 40 x 40 x 15 XS8E1A1MAL2 88.00 XS8C1A1MAL2 XS8E1A1MBL2 88.00 XS8C1A1MBL2 Connection: 1/2" 20 UNF connector XS8E1A1MAL01U20 101.00 XS8C1A1MAL01U20 XS8E1A1MBL01U20 101.00 XS8C1A1MBL01U20 20–264 20–264 200 300 yes / yes yes / yes < 1.5 < 1.5 < 5.5 < 5.5 50 / 1000 50 / 1000 d Requires a 0.8 A quick-blow fuse in series with the load. Table 20.4: 20-4 Type C (40 x 40 mm) 15 mm 0–10 / 0–15 5–10 / 5–15 shielded or non-shielded via Osiconcept teach mode P –13 to 158 (–25 to 70) pre-cabled: IP68 (with connector: IP67) Discount Schedule Straight $ Price 90o Adapter plate $ Price for block-type sensors XS•E / XS•C / XS•D $ Price Type E XSZBE00 8.00 XSZBE90 8.00 XSZBE10 9.00 Type C XSZBC00 8.00 XSZBC90 8.00 XSZBC10 10.00 Type D — XSZBD10 11.00 Modified 4/17/09 — — — © 2007 Schneider Electric All Rights Reserved www.us.schneider-electric.com Osiprox® Proximity Sensors XS Plastic Tubular Refer to Catalog 9006CT0101 FOR CURRENT INFORMATION New! non-flush mountable in metal flush mountable in metal A single product that automatically adapts to most environments. Accurate position detection via teach mode. Ø 12 mm $ Price Ø 18 mm 5 mm 9 mm 0–3.4 / 0–5 0–7 / 0–10 1.7–3.4 / 1.7–5 3.5–7 / 3.5–10 shielded or non-shielded via Osiconcept teach mode M M –13 to 158 (–25 to 70) –13 to 158 (–25 to 70) pre-cabled: IP68 (with connector: IP67) Connection: pre-cabled PvR (2 m) M12 x 54 — — — — — — — — Dimensions (mm), Ø x L PNP N.O. PNP N.C. 3-wire NPN N.O. NPN N.C. Connection: M8 or M12 connector PNP N.O. XS612B2PAL01M12 a PNP N.C. XS612B2PBL01M12 a 3-wire NPN N.O. XS612B2NAL01M12 a NPN N.C. XS612B2NBL01M12 a Supply voltage limits min/max (V), including ripple 10–36 Switching capacity max (mA) 200 Short-circuit protection yes LED output state indication / power on LED yes / yes Voltage drop, closed state (V) at I nominal <2 Switching frequency (Hz) 1000 a Pigtail cable (L + 0.25 m) with end-mounted remote control and M12 connector. Table 20.5: 87.00 87.00 87.00 87.00 Accessories M18 x 67 — — — — $ Price Ø 30 mm 18 mm 0–12 / 0–18 6–12 / 6–18 M –13 to 158 (–25 to 70) M30 x 71 — — — — — — — — XS618B2PAL01M12 a XS618B2PBL01M12 a XS618B2NAL01M12 a XS618B2NBL01M12 a 10–36 200 yes yes / yes <2 1000 XS630B2PAL01M12 a XS630B2PBL01M12 a XS630B2NAL01M12 a XS630B2NBL01M12 a 10–36 200 yes yes / yes <2 1000 105.00 105.00 105.00 105.00 Mounting bracket with indexing pin for cylindrical sensors For Osiconcept XS6 remote control $ Price — — — — 114.00 114.00 114.00 114.00 $ Price $ Price XSZBPM12 5.00 Connectors 90° straight M12 XSZB112 4.00 M18 XSZB118 4.70 M30 XSZB130 4.70 Snap-C Plug-in female connectors, including pre-wired versions 2 m long, without LED Catalog No. XSZCS111 XSZCD111Y XSZCK101Y M8 M12 U20 Catalog No. XSZCS101 XSZCD101 XSZCK111Y $ Price Catalog No. 13.50 — b XZCC12FDM40V 15.00 — $ Price — 9.00 — Consult the factory. 20 b $ Price 14.30 13.50 15.00 ELECTRONIC SENSORS AND MACHINE CABLING Specifications Nominal Sensing Distance Usable sensing distance S (mm), shielded/non-shielded Precision adjustment range (mm), shielded/non-shielded Mounting in metal Enclosure M (metal), P (plastic) Temperature range oF (oC) Degree of protection (conforming to IEC 60529) Sensors for DC applications (3-wire) © 2007 Schneider Electric All Rights Reserved DS2 Discount Schedule Modified 4/17/09 20-5 Osiprox® Proximity Sensors XS Basic Series Refer to Catalog 9006CT0101 www.us.schneider-electric.com FOR CURRENT INFORMATION New! Basic Series Cylindrical, Stainless Steel Flush and Non-Flush Mountable Three-Wire, DC Supply, Solid-State Output Sensing Characteristics Sensing Range Switching Frequency Shock Resistance Vibration Resistance Ø 6.5 plain flush mountable 0–1.2 mm (0–0.047 in.) 3000 Hz 50 gn, duration 11 ms 25 gn, amplitude ± 2 mm (10–55 Hz) Ø M8 Ø M8 flush mountable non-flush mountable 0–1.2 mm (0–0.047 in.) 0–2.0 mm (0–0.078 in.) 3000 Hz 50 gn, duration 11 ms 25 gn, amplitude ± 2 mm (10–55 Hz) Ø M12 Ø M12 flush mountable non-flush mountable 0–1.6 mm (0–0.062 in.) 0–3.2 mm (0–0.125 in.) 2000 Hz 1000 Hz 50 gn, duration 11 ms 25 gn, amplitude ± 2 mm (10–55 Hz) 12–24 Vdc w/protection against reverse polarity 10–36 Vdc 12–24 Vdc w/protection against reverse polarity 10–36 Vdc 12–24 Vdc w/protection against reverse polarity 10–36 Vdc –25 to 70 °C (–13 to 158 °F) IP67 –25 to 70 °C (–13 to 158 °F) IP67 –25 to 70 °C (–13 to 158 °F) IP67 Power Requirements Supply Voltage Voltage limits (including ripple) Environmental Operating Temperature Range Environmental Protection Ratings Construction Housing Material Output Type N.O. PNP N.O. NPN N.C. PNP N.C. NPN Nickel Plated Brass Catalog No. Pre-cabled (2 m) M8 connector M12 connector Pre-cabled (2 m) M8 connector M12 connector Pre-cabled (2 m) M8 connector M12 connector Pre-cabled (2 m) M8 connector M12 connector Sensing Characteristics Sensing Range Switching Frequency Shock Resistance Vibration Resistance Nickel Plated Brass $ Price XS106BLPAL2 — — XS106BLNAL2 — — XS106BLPBL2 — — XS106BLNBL2 — — 49.00 — — 49.00 — — 49.00 — — 49.00 — — Catalog No. XS108BLPAL2 XS108BLPAM8 XS108BLPAM12 XS108BLNAL2 XS108BLNAM8 XS108BLNAM12 XS108BLPBL2 XS108BLPBM8 XS108BLPBM12 XS108BLNBL2 XS108BLNBM8 XS108BLNBM12 $ Price 55.00 59.00 59.00 55.00 59.00 59.00 55.00 59.00 59.00 55.00 59.00 59.00 Ø M18 Ø M18 flush mountable non-flush mountable 0–4 mm (0–0.157 in.) 0–6.4 mm (0–0.251 in.) 2000 Hz 250 Hz 50 gn, duration 11 ms 25 gn, amplitude ± 2 mm (10–55 Hz) Nickel Plated Brass Catalog No. XS208BLPAL2 XS208BLPAM8 XS208BLPAM12 XS208BLNAL2 XS208BLNAM8 XS208BLNAM12 XS208BLPBL2 XS208BLPBM8 XS208BLPBM12 XS208BLNBL2 XS208BLNBM8 XS208BLNBM12 $ Price 55.00 59.00 59.00 55.00 59.00 59.00 55.00 59.00 30.00 55.00 59.00 59.00 Catalog No. XS112BLPAL2 XS112BLPAM8 XS112BLPAM12 XS112BLNAL2 XS112BLNAM8 XS112BLNAM12 XS112BLPBL2 XS112BLPBM8 XS112BLPBM12 XS112BLNBL2 XS112BLNBM8 XS112BLNBM12 $ Price 45.00 a 45.00 45.00 a 45.00 45.00 a 45.00 45.00 a 45.00 Catalog No. XS212BLPAL2 XS212BLPAM8 XS212BLPAM12 XS212BLNAL2 XS212BLNAM8 XS212BLNAM12 XS212BLPBL2 XS212BLPBM8 XS212BLPBM12 XS212BLNBL2 XS212BLNBM8 XS212BLNBM12 $ Price 45.00 a 45.00 45.00 a 45.00 45.00 a 45.00 45.00 a 45.00 Ø M30 Ø M30 flush mountable non-flush mountable 0–8 mm (0–0.314 in.) 0–12 mm (0–0.472 in.) 200 Hz 60 Hz 50 gn, duration 11 ms 26 gn, amplitude ± 2 mm (10–55 Hz) Power Requirements Supply Voltage Voltage Limits (including ripple) 12–24 Vdc w/protection against reverse polarity 10–36 Vdc 12–24 Vdc w/protection against reverse polarity 10–36 Vdc –25 to 70 °C (–13 to 158 °F) IP67 –25 to 70 °C (–13 to 158 °F) IP67 Environmental Operating Temperature Range Environmental Protection Ratings Construction Housing Material Output Type 20 ELECTRONIC SENSORS AND MACHINE CABLING a Nickel Plated Brass Catalog No. Pre-cabled (2 m) N.O. M8 connector PNP M12 connector Pre-cabled (2 m) N.O. M8 connector NPN M12 connector Pre-cabled (2 m) N.C. M8 connector PNP M12 connector Pre-cabled (2 m) N.O. M8 connector NPN M12 connector Consult the factory for current pricing XS118BLPAL2 XS118BLPAM8 XS118BLPAM12 XS118BLNAL2 XS118BLNAM8 XS118BLNAM12 XS118BLPBL2 XS118BLPBM8 XS118BLPBM12 XS118BLNBL2 XS118BLNBM8 XS118BLNBM12 Nickel Plated Brass $ Price 45.00 a 45.00 45.00 a 45.00 45.00 a 45.00 45.00 a 45.00 Catalog No. XS218BLPAL2 XS218BLPAM8 XS218BLPAM12 XS218BLNAL2 XS218BLNAM8 XS218BLNAM12 XS218BLPBL2 XS218BLPBM8 XS218BLPBM12 XS218BLNBL2 XS218BLNBM8 XS218BLNBM12 $ Price 45.00 a 45.00 45.00 a 45.00 45.00 a 45.00 45.00 a 45.00 Catalog No. XS130BLPAL2 XS130BLPAM8 XS130BLPAM12 XS130BLNAL2 XS130BLNAM8 XS130BLNAM12 XS130BLPBL2 XS130BLPBM8 XS130BLPBM12 XS130BLNBL2 XS130BLNBM8 XS130BLNBM12 $ Price 48.00 a 48.00 48.00 a 48.00 48.00 a 48.00 48.00 a 48.00 Catalog No. XS230BLPAL2 XS230BLPAM8 XS230BLPAM12 XS230BLNAL2 XS230BLNAM8 XS230BLNAM12 XS230BLPBL2 XS230BLPBM8 XS230BLPBM12 XS230BLNBL2 XS230BLNBM8 XS230BLNBM12 $ Price 48.00 a 48.00 48.00 a 48.00 48.00 a 48.00 48.00 a 48.00 Mounting Bracket W / Indexing Pin for Cylindrical Sensors Connector M8 M12 M18 M30 Catalog No. XSZB108 XSZB112 XSZB118 XSZB130 $ Price 3.20 4.00 4.70 4.70 Cable Connectors Plug-in female connectors, including pre-wired versions, 2 m long, without LED 20-6 Connector M8 M12 90° Catalog No. XSZCS111 XSZCD111Y $ Price 14.30 13.50 DS2 Straight Catalog No. $ Price XSZCS101Y 13.50 XSZCD101Y 14.00 Discount Schedule Modified 4/17/09 © 2007 Schneider Electric All Rights Reserved Osiprox® Proximity Sensors www.us.schneider-electric.com Food, Beverage, and Pharmaceutical / Ultrasonic Accessories Refer to Catalog 9006CT0101 FOR CURRENT INFORMATION Table 20.6: Food, Beverage, and Pharmaceutical Offering New! Cylindrical, Stainless Steel, Non-flush Mountable Three-Wire DC Supply, Solid-State Output Sensing Characteristics Sensing Range Switching Frequency Shock Resistance Vibration Resistance Ø M12 threaded M12 x 1 0–5.6 mm (0–0.22 in.) 2500 Hz 50 gn, duration 11 ms 25 gn, amplitude ± 2 mm (10–55 Hz) Power Requirements Supply Voltage (w/protection against reverse polarity) Voltage limits (including ripple) Environmental Operating Temperature Environmental Protection Ø M18 threaded M18 x 1 0–9.6 mm (0–0.377 in.) 1000 Hz 50 gn, duration 11 ms 25 gn, amplitude ± 2 mm (10–55 Hz) Ø M18 plain 0–9.6 mm (0–0.377 in.) 1000 Hz '50 gn, duration 11 ms '25 gn, amplitude ± 2 mm (10–55 Hz) Ø M30 threaded M30 x 1.5 0–17.6 mm (0–0.692 in.) 500 Hz 50 gn, duration 11 ms 25 gn, amplitude ± 2 mm (10–55 Hz) 12–24 Vdc 12–24 Vdc 12–24 Vdc 12–24 Vdc 10–36 Vdc 10–36 Vdc 10–36 Vdc 10–36 Vdc -25 to 85 °C (-13 to 158 °F) IP67, IP68, IP69 -25 to 70 °C (-13 to 158 °F) IP67, IP68, IP69 -25 to 70 °C (-13 to 158 °F) IP67, IP68, IP69 -25 to 70 °C (-13 to 158 °F) IP67, IP68, IP69 Construction Housing Material Stainless Steel PPS Stainless Steel PPS Output Type Stainless Steel Stainless Steel PPS XS230SAPAL2 57.70 XS230SAPAM12 57.00 Catalog No. $ Price N.O., PNP Pre-cabled (2 m) M12 connector XS212SAPAL2 51.80 XS212SAPAM12 51.80 XS212AAPAL2 33.30 XS212AAPAM12 33.30 XS218SAPAL2 51.80 XS218SAPAM12 51.80 XS218AAPAL2 33.30 XS218AAPAM12 33.30 XS2L2SAPAL2 55.80 XS2L2SAPAM12 55.80 — XS212SANAL2 51.80 XS212SANAM12 51.80 XS212AANAL2 33.30 XS212SANAM12 33.30 XS218SANAL2 51.80 XS218SANAM12 51.80 XS218AANAL2 33.30 XS218AANAM12 33.30 XS2L2SANAL2 55.80 XS2L2SANAM12 55.80 — — N.O., NPN Pre-cabled (2 m) M12 connector Two-wire AC or DC Supply, Solid-State Output Sensing Characteristics Ø M18 threaded M18 x 1 Table 20.8: Sensing Range Switching Frequency Shock Resistance Vibration Resistance 0–9.6 mm (0–0.377 in.) 300 Hz 50 gn, duration 11 ms 25 gn, amplitude ± 2 mm (10–55 Hz) 0–17.6 mm (0–0.692 in.) 200 Hz 50 gn, duration 11 ms 25 gn, amplitude ± 2 mm (10–55 Hz) Power Requirements Supply Voltage (w/protection against reverse polarity) Voltage limits (including ripple) 12–24 Vdc 12–24 Vdc 10–36 Vdc 10–36 Vdc -25 to 70 °C (-13 to 158 °F) IP67, IP68, IP69 -25 to 70 °C (-13 to 158 °F) IP67, IP68, IP69 Construction Housing Material Stainless Steel PPS Output Type Stainless Steel PPS 90° M12 4-pin connector XS218SAMAL2 72.50 XS218AAMAL2 46.60 XS230SAMAL2 79.80 XS230AAMAL2 51.30 1/2"-20 UNFconnector XS218SAMAU20 72.50 XS218AAMAU20 46.60 XS230SAMAU20 79.80 XS230AAMAU20 51.30 a 4.00 XSZB118 4.70 M30 XSZB130 4.70 Two-wire $ Price Catalog No. a — a XZCPA1865L10 a XZCPA1865L5 a 2 m XZCPA1241L2 — a XZCPA1965L10 a XZCPA1965L5 5 m XZCPA1241L5 10 m XZCPA1241L10 Call factory for current pricing. $ Price — a a — a a Ultrasonic Sensors Accessories Teachable Pushbutton Accessory for Virtu Series Catalog No. $ Price XXZPB100 29.00 Table 20.10: Mounting Brackets Body Type M12 Python AC/DC Power Convertor Catalog No. 9006PA12 $ Price 3.20 M18 9006PA18 3.20 M30 9006PA30 4.20 $ Price 99.00 Connector Cables Type Sensor Suffix Connector Style NANO 6.6 ft (2 m) Cable, PVC Material Non-Locking DC 3 Pin—without LED S, M8 DC 3 Pin—without LED S, M8 Locking DC 3 Pin—without LED S, M8 DC 3 Pin—without LED S, M8 DC 4 Pin—without LED S, M8 DC 4 Pin—without LED S, M8 Self-assembled Connector Snap-C connector — © 2007 Schneider Electric All Rights Reserved Catalog No. $ Price Straight 90° XSZCS901 XSZCS911 12.80 12.80 Straight 90° Straight 90° XSZCS101 XSZCS111 XSZCS141 XSZCS151 13.50 14.30 14.30 16.50 Straight XZCC12FDM40V 9.00 DS2 Discount Schedule Type Sensor Suffix Connector Style Micro 6.6 ft (2 m) Cable, PVC Material DC 4 Pin—without LED D, M12 DC 4 Pin—without LED D, M12 DC 5 Pin—without LED D, M12 DC 5 Pin—without LED D, M12 AC/DC 3 Pin—without LED K, U20 AC/DC 3 Pin—without LED K, U20 Mini 6.6 ft (2 m) Cable, PVC Material DC 3 Pin—without LED A, R3 DC 3 Pin—without LED A, R3 AC/DC 3 Pin—without LED A, R3 AC/DC 3 Pin—without LED A, R3 Modified 4/17/09 Catalog No. $ Price Straight 90° Straight 90° Straight 90° XSZCD101Y XSZCD111Y XSZCD1501Y XSZCD1511Y XSZCK111Y XSZCK101Y 13.50 13.50 22.50 22.50 15.00 15.00 Straight 90° Straight 90° XSZCA101Y XSZCA111Y XSZCA901Y XSZCA911Y 18.00 18.00 16.50 16.50 20-7 ELECTRONIC SENSORS AND MACHINE CABLING Catalog No. XXZPM100M12 Table 20.11: $ Price M18 Catalog No. 2 m XZCPA1141L2 Straight M12 4-pin connector 5 m XZCPA1141L5 10 m XZCPA1141L10 Pre-cabled (2 m) Table 20.9: Catalog No. Three-wire Cable Connectors Catalog No. $ Price N.O. Body Type Mounting bracket with indexing pin for cylindrical sensors M12 XSZB112 Environmental Operating Temperature Environmental Protection Accessories Brackets Ø M30 threaded M30 x 1.5 — 20 Table 20.7: XS230SANAL2 57.00 XS230SANAM12 57.00 Ultrasonic Sensors Refer to Catalog 9006CT0101 www.us.schneider-electric.com FOR CURRENT INFORMATION Table 20.12: Specifications and Catalog Numbers New! Virtu® VM1 and VM18 12 mm / Flat profile M12 18 mm / Flat profile M18 Sensing Characteristics Sensing Range 51–508 mm (2–20 in.) Sensing Frequency 300 kHz 51–127 mm (2.0–5.0 in.) 500 kHz 51–254 mm (2–10 in.) 500 kHz 12–24 Vdc 25 mA (excluding load) 12–24 Vdc 50 mA (excluding load) -30 to 70 °C (-22 to 158 °F) 0 to 60 °C (32 to 140 °F) NEMA 4X, IP67 NEMA 4X, IP67 12 x 1 mm threaded housing 7.62 x 33.0 x 19.05 mm (0.3 x 1.3 x 0.75 in.) ULTEM® Glass Epoxy 18 x 1 mm threaded housing 16.25 x 30 x 84.40 mm (1.182 x 0.640 x 3.322 in.) ULTEM® Silicon Rubber Power Requirements Supply Voltage Supply Current 12–24 Vdc 40 mA (excluding load) Environmental Ratings Operating -30 to 70 °C (-22 to 158 °F) Temperature Environment NEMA 4X, IP67 Construction Barrel, ØxL Flat Profile, wxhxd Housing Material Transducer 18 x 77.62 mm (0.70 x 3.06 in.) 43.7 x 18 x 59.7 mm (1.72 x 0.70 x 2.35 in.) Valox® Glass Epoxy Output Type Catalog Number Output Proximity Output PNP Sourcing NPN Sinking N.O. N.C. N.O. N.C. Quick Disconnect a VM1PNOQ VM18PNOQ VM1PNCQ VM18PNCQ VM1NNOQ VM18NNOQ VM1NNCQ VM18NNCQ $ Price Cable N.O. N.C. 89.00 Connector N.O. N.C. Cable N.O., pump-out latch N.O., pump-in latch Dual-Level Barrel b SM300A46000 SM300A46010 SM350A46000 SM350A46010 Barrel b SM302A42000 SM302A42010 Connectors Barrel b N.O., pump-out latch SM352A42000 N.O., pump-in latch SM352A42010 Auto Direct Inverse Quick Disconnect a VM1VAQ VM18VAQ VM1VDQ VM18VDQ VM1VIQ VM18VIQ $ Price 129.00 129.00 129.00 Auto Direct Inverse VM1CAQ VM1CDQ VM1CIQ 129.00 129.00 129.00 Voltage Slope VM18CAQ VM18CDQ VM18CIQ 159.00 169.00 $ Price 159.00 $ Price 169.00 N.O. N.C. Connector N.O. N.C. Cable Pump-out latch Pump-out latch, LOE Pump-in latch Pump-in latch, LOE Dual alarm, N.O. Dual alarm, N.O., LOE Dual alarm, N.C. Dual alarm, N.C., LOE Connectors Pump-out latch Pump-out latch, LOE Pump-in latch Pump-in latch, LOE Dual alarm, N.O. Dual alarm, N.O., LOE Dual alarm, N.C. Dual alarm, N.C., LOE Cable Inverse slope Inverse slope, LOE Direct slope Direct slope, LOE Inverse slope Inverse slope, LOE Direct slope Direct slope, LOE Connector Current Slope $ Price Cable 20 Analog ELECTRONIC SENSORS AND MACHINE CABLING Inverse slope Inverse slope, LOE Direct slope Direct slope, LOE Inverse slope Inverse slope, LOE Direct slope Direct slope, LOE a b c Barrel b SM600A21600 SM600A21610 SM650A21600 SM650A21610 Barrel b SM602A60400 SM602A60403 SM602A60410 SM602A60413 SM602A60420 SM602A60423 SM602A60430 SM602A60433 Barrel b SM652A60400 SM652A60403 SM652A60410 SM652A60413 SM652A60420 SM652A60423 SM652A60430 SM652A60433 Barrel b Current SM606A44800FPc SM606A44803FPc SM606A44801FPc SM606A44806FPc SM606A44810FPc SM606A44813FPc SM606A44811FPc SM606A44816FPc Barrel b Voltage SM656A44800 SM656A44803 SM656A44801 SM656A44806 Current SM656A44810 SM656A44813 SM656A44811 SM656A44816 $ Price 325.00 347.00 $ Price 335.00 412.00 $ Price 357.00 $ Price 391.00 468.00 $ Price 413.00 413.00 Cable models are available from the Virtu VM1 series. Consult the factory. Flat profile models are available. Consult the factory. Not available in barrel style. NOTE: LOE = hold on loss of echo 20-8 DS2 Discount Schedule Modified 4/17/09 © 2007 Schneider Electric All Rights Reserved Ultrasonic Sensors Refer to Catalog 9006CT0101 www.us.schneider-electric.com FOR CURRENT INFORMATION Table 20.13: Specifications and Catalog Numbers New! 30 mm (1 or 2 m cable) M30 Virtu® 30 mm 30 mm (8 m) M30 Sensing Characteristics Sensing Range 102–1000 mm (4–39 in.) Sensing 180 kHz Frequency Power Requirements 51 mm to 1 m (2–39 in.); 119 mm to 2 m (4.7–79 in.) 203 mm to 8 m (8–315 in.) 200 kHz 200 kHz Supply Voltage Supply Current 12–24 Vdc Discrete; 15–24 Vdc Analog 12–24 Vdc Discrete; 15–24 Vdc Analog NEMA 4X, IP67 NEMA 4X, IP67 ULTEM Silicon Rubber ULTEM Glass Epoxy 12–24 Vdc 60 mA (excluding load) Environmental Ratings Operating -30 to 70 °C (-22 to 158 °F) Temperature Environment NEMA 4X, IP67 Construction Output Type 30 x 1 x 95.26 mm (1.18 x 3.75 in.) — PBT Valox 553 Glass Epoxy Description Catalog No. $ Price Description Catalog No. Quick Disconnect Proximity Output $ Price Catalog No. $ Price 8m PNP Sourcing NO XX6V3A1PAM12 Connector SM950A100000 422.00 Cable SM900A800000 648.00 PNP Sourcing NC XX6V3A1PBM12 Cable SM900A100000 411.00 Connector SM950A800000 659.00 NPN Sinking NO XX6V3A1NAM12 NPN Sinking NC XX6V3A1NBM12 Connector SM950A400000 453.00 Cable SM900A400000 442.00 169.00 2m 1ma Cable Pump-out latch Pump-out latch w/alarm Pump-out latch, w/setpoint Pump-in latch Pump-in latch w/alarm Pump-in latch, w/setpoint Dual setpoint Dual alarm Dual-Level SM902A100000 SM902A150000 SM902A170000 SM902A110000 SM902A140000 SM902A160000 SM902A120000 SM902A130000 Cable 411.00 Connector Quick Disconnect 0–10 Vdc XX9V3A1A1M12 4–20 Vdc XX9V3A1A2M12 SM952A100000 SM952A150000 SM952A170000 SM952A110000 SM952A140000 SM952A160000 SM952A120000 SM952A130000 422.00 587.00 422.00 657.00 422.00 1ma Cable 169.00 Pump-out latch Pump-out latch w/alarm Pump-out latch, w/setpoint Pump-in latch Pump-in latch w/alarm Pump-in latch, w/setpoint Dual setpoint Dual alarm Cable Voltage SM902A800000 SM902A850000 SM902A870000 SM902A810000 SM902A840000 SM902A860000 SM902A820000 SM902A830000 648.00 SM952A800000 SM952A850000 SM952A870000 SM952A810000 SM952A840000 SM952A860000 SM952A820000 SM952A830000 659.00 8m Voltage Auto slope Direct slope Inverse slope SM906A180000 SM906A110000 SM906A100000 Auto slope Direct slope Inverse slope SM906A190000 SM906A130000 SM906A120000 540.00 470.00 Current Analog 8m Pump-out latch Pump-out latch w/alarm Pump-out latch, w/setpoint Pump-in latch Pump-in latch w/alarm Pump-in latch, w/setpoint Dual setpoint Dual alarm Connector Pump-out latch Pump-out latch w/alarm Pump-out latch, w/setpoint Pump-in latch Pump-in latch w/alarm Pump-in latch, w/setpoint Dual setpoint Dual alarm Auto slope Direct slope Inverse slope SM906A880000 SM906A810000 SM906A800000 690.00 Auto slope Direct slope Inverse slope SM906A890000 SM906A830000 SM906A820000 690.00 Auto slope Direct slope Inverse slope SM956A880000 SM956A810000 SM956A800000 700.00 Auto slope Direct slope Inverse slope SM956A890000 SM956A830000 SM956A820000 700.00 Current 470.00 Connector Connector Voltage Voltage Auto slope Direct slope Inverse slope SM956A180000 SM956A110000 SM956A100000 Auto slope Direct slope Inverse slope SM956A190000 SM956A130000 SM956A120000 480.00 Current Current 480.00 2 m devices are also available. Consult the factory. 20 a Description 1m ELECTRONIC SENSORS AND MACHINE CABLING Barrel, ØxL Flat Profile, wxhxd Housing Material Transducer © 2007 Schneider Electric All Rights Reserved DS2 Discount Schedule 20-9 Ositrack® RFID Radio Frequency Identification Refer to Catalog 9006CT0101 www.us.schneider-electric.com FOR CURRENT INFORMATION Table 20.14: ® Ositrack RFID Products and Accessories New! Electronic Tags C format ISO Badge Disc E format Cylindrical Nominal Sensing Distance With station XGCS49 With station XGCS89 Dimensions (W x H x D) Memory Capacity Type of Memory 33 48 30 40 70 100 54 x 85.5 x 0.8 mm 13 632 EEPROM 40 x 40 x 15 mm 3 405 EEPROM 48 65 Ø x 30 x 3 mm 112 EEPROM 40 55 26 x 26 x 13 mm 256 EEPROM 18 20 M18 x 1 x 12 mm 256 EEPROM Time (ms) Read Write Ordering Information 9.25 + 375 n x (3) 16.25+ 375 x n (3) 12 + 0.825 n (3) 12 + 0.825 n (3) 12 + 0.825 n (3) 13 + 0.8 x n (3) 20 + 0.8 x n (3) 20 + 11.8 x n (3) 12 + 5.6 x n (3) 20 + 11.8 x n (3) Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price Catalog No. $ Price XGHB444345 105.00 XGHB445345 130.00 XGHB90E340 10.00 XGHB320345 20.00 XGHB221346 45.00 Compact Stations, 13.56 MHz Dimensions (W x H x D) C Format D Format 40 x 40 x 15 80 x 80 x 26 Normal Sensing Distance (depending on associated tag) Ordering Information Connection boxes Ordering Information Portable Terminal Function Operating System 20 Ordering Information 20–100 Catalog Number XGCS4901201 $ Price 600.00 TCSESU051F0 Catalog Number XGCS8901201 Catalog Number XGSZ33ETH a Pre-wired M12, 4-pin female connector, A Coding Modbus®, Uni-Telway and CANopen (1) XGCS49 and XGCS89 24 V $ Price Catalog Number 875.00 TGSAMT31FP — — $ Price $ Price 790.00 Tap-off box Modbus® TCP/IP For 13.56 MHz RFID diagnostics Read/Write operations on electronic tags and diagnostics on compact stations Microsoft Windows® CE.NET Professional version 4.2 Catalog Number XGSTP401 $ Price Catalog No. XGSX08L2 XGSX08L5 XGSX08L10 2m 5m 10 m $ Price 10.00 20.00 15.00 Network T connector M12, 1 male/2 female 5-pin, A Coding $ Price 6050.00 Catalog Number TCSCTN011M11F $ Price 45.00 Ositrack® RFID Cables ELECTRONIC SENSORS AND MACHINE CABLING Ethernet Shielded connecting cable, ConneXium (2), M12 male D coding/RJ45, 4-pin Length Catalog No. 1m TCSECL1M3M1S2 3m TCSECL1M3M3S2 5m TCSECL1M3M5S2 10 m TCSECL1M3M10S2 40 m TCSECL1M3M40S2 a Call factory for current pricing. 20-10 Catalog Number 18–70 Ethernet box Protocols Associated compact stations Supply Voltage Table 20.15: M12 Ethernet switch Modbus® TRU, Uni-Telway and CANopen (1) Protocols 12 + 0.825 n (3) 19 + 4.1 x n (3) Catalog No. $ Price XGHB211345 35.00 Modus shielded connection cable, M12/SUB-D15, A Coding $ Price Length a a a 2m a a Catalog No. TCSMCN1FQM2 DS2 Discount Schedule Modified 4/17/09 Modbus® shielded connection cable, M12/Mini-DIN 8-way, A Coding $ Price Length 50.00 2m Catalog No. $ Price TCSMCN1F9M2P 65.00 © 2007 Schneider Electric All Rights Reserved