SECURITY DOOR CONTROLS 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 • Fax: (805) 494-8861 www.sdcsecurity.com • E-mail: [email protected] REGULATED POWER SUPPLY INSTALLATION INSTRUCTIONS MODEL 636RF FIGURE A COMPONENT LOCATIONS AC INPUT: GRN – GROUND WHT – NEUTRAL BLK - HOT AC INPUT CIRCUIT BREAKER FIGURE B CONTROL MODULE CONTROL MODULE CONTROL MODULE CONTROL MODULE POWER SUPPLY BOARD BATTERY 1 7ah BATTERY 1 7ah STANDARD BOX CLASS 2 OUTPUTS 6 AMP OUTPUT AUXILIARY RELAY CONNECTION SYSTEM STATUS LED 2A + 2A + 2A + MAIN SYSTEM ON-OFF FIGURE C Master ON/OFF Switch (N/C) _+ MAIN C + _ C MANUAL RESET Min. Switch or Contact Ratings 100mA @ 30VDC VOLTAGE SELECT + BATTERY LED STATUS LEGEND: YELLOW – SYSTEM OK RED – NO AC INPUT GREEN – NO DC OUTPUT _ BATTERY INPUT TERMINALS 24V 12V 24V POSITION 12V POSITION POWER SUPPLY SPECIFICATIONS Input Voltage: 115 VAC @ 60hz Input Current: 1.8 amps Max. Output Voltage: 12/24VDC (Regulated) Output Current: 6 amps Ripple Voltage: 0.05 Volts Max. VOLTAGE SELECTION NOTE: POWER MUST BE TURNED OFF BEFORE CHANGING VOLTAGE 12 Volt Mode Battery Connections SWITCH SET FOR 24VDC SWITCH SET FOR 12VDC Battery Charger Max. Current: 0.35 amps Maximum recommended battery size: 7 ah (Replace batteries every 3 years) Suitable Uses: Electric Lock Power Supply Access Control Power Supply 24 Volt Mode Battery Connections + + _ + _ _ + 12VDC TEST UNIT YEARLY P:\INSTALLATION INST\Power Supplies\INST-636RF\INST-636RF.VSD Rev F 06-06 _ 12VDC + _ 12VDC