Preview only show first 10 pages with watermark. For full document please download

Security Technology

   EMBED


Share

Transcript

2013 security technology intruder alarm systems s addressable fire alarm systems s conventional fire alarm systems peace of mind EN 2013-1 PRODUCT CATALOGUE security technology TEKNIM is an ISO 9001:2008 certificated manufacturer in security products market, located in Istanbul-Turkey .It has its own Research & Development department and all its production facility is in Turkey. TEKNIM, is a high-tech company which designs and produces alarm control panels, detectors, other fire detection and intruder alarm products, sells both abroad and within the domestic markets through distributors & retailers. In this area, especally in very advanced and complete alarm systems technology development, TEKNIM is one of the biggest company in Turkey in terms of design and production. Although TEKNIM is a very young company, in Turkish market, it has left behind the world leading brands and gained confidence of hundreds of companies and alarm systems consumers in a very short period and has a significant market share and growth since then. TEKNIM, besides intruder alarm systems ,also design and manufactures fire detection systems from 2008 and on. Produced by TEKNIM, fire alarm panels and other fire products are being very much appreciated by consumers as well as industry professionals. TEKNIM, Turkey's one of the leading manufacturer of alarm systems, is the only exporter of bearing its name as TEKNIM and has become one of the most important brands. In addition to the domestic success, TEKNIM products are being exported to many countries in Europe, Africa and Asia. TEKNIM, as a manufacturer of intruder alarm systems and fire alarm systems, proudly represents our country in abroad with the TEKNIM brand with an ongoing success. Contents: INTRUDER ALARM SYSTEMS . . . 2 Alarm Panels ...............................................6 Alarm Keypads ..........................................16 Optional Modules.......................................19 PIR Detectors ............................................23 Smoke Detectors .......................................26 Gas Detectors............................................27 Other Detectors .........................................28 Outdoor & Indoor Sirens ............................30 CONTINUOUS POWER SUPPLIES . . . . . . . . . . . . . . . . . 32 CONVENTIONAL FIRE ALARM SYSTEMS. . . . . . . . . . . 33 Fire Alarm Panels ......................................34 Fire Detectors ............................................37 Indoor Fire Sirens & Strobes .....................39 Outdoor Fire Sirens & Gas Detectors ........40 www.teknim.com | [email protected] To be surrounded by wire fences... Is it enough for your safety? INTRUDER ALARM SYSTEMS What can you do with VAP Series Alarm Panels? Whether you are at home or not, YOU CAN... ...turn on the heater and have your home warm in cold winter days before you arrive home, ...run the irrigation system ...turn on the oven to make your meal ready at the time you arrive home, ... or shut the window shades. Teknim Security Technology, as one of the leading manufacturers of security sector in Turkey, we work for your life to be easier so you have more spare time for your beloved ones... You ensure your security with aesthetic, strong and easy to use high technology Teknim products, you don't even have to get up from where you sit... Anywhere in the World, the only thing you need is a mobile phone or a computer... 4 6 VAP Series Alarm Panels with Plastic Box PCB: - Eco-friendly production techniques - Lead-free material - Microprocessor design - Advanced features - High performance, low error range FUSED CONNECTOR: - Simple connection and protected connection node TAMPER SWITCH: - Forth/back tamper switch protection against cover removal or back case removal PLASTIC BOX: - High quality, resistant to damage, lead-free and strong case ADAPTER: - Efficient, SMPS BATTERY: - 12V 7AH battery slot CONNECTION DUCTS: - Easy to connect cables that came outside panel trough the openings ZONEx2 x2 Zone Doubling Min 7 standart users + 1 guest user password 2 or more keypad connections supported 256 Event log memory with 256 date and time information Dialer SPT Smart Partitioning Technology Contact ID communicator 5 Alarm Panels Intruder Alarm Sytems One panel, four independent systems Especially for small and medium sized residental and commercial areas, this feature lets the users divide the area up to 4 separate parts and use each part as compeletely independent systems via 4 separate keypads. Each keypad has its own address and they do not effect each other. Conventional Fire Alarm Systems Users can arm/disarm each partition separately or together. Keypads, partitions, sirens, phone numbers and authorizations of users can be assigned independently. VAP-416 M Alarm Panel VAP-416 Alarm Control Panel is the perfect high-end security and automation solution for medium and large sized residential and commercial areas. It is not only an alarm panel but also an automation system with 3 PGM outputs and periodic timers. Users may activate an electronic system such as irrigation system, air-condition, oven etc. in a determined time period by using PGM output. Users may arm/disarm panel and control PGM outputs remotely by phone. VAP-416 Alarm Control Panel can be controlled and monitored locally or remotely from a local PC or network/internet PC via VAPMAN Alarm Management Software. Its easy installation and user-friendly usage make it attractive both for installers and end users. Metal box only General Features 16 + 16 zones • 16 zones on main control panel, expandable to 20 zones with optional zone expansion module and to 32 zones with hardwire zone-doubling • Using each zone with NC or NO contacts devices with or without EOL resistors • Selecting each zone as 12 different type (door, window, home, away, 24 hours, fire, tamper, panic…etc.) • Entry/Exit delays for each partition • Adjustable zone response speed • Additional features of the zones (Entry/exit zone, follower zone, last-door zone, zone with audio / silent…etc.) • Arming panel automatically without delay time by determining Entry/Exit zones, when someone exits from last-door • Adjusting each zone as special zone in order to transmit alarm message to the central station without alarm siren (for gas detectors, flood detectors) 6 • Selectable cross zone and double hit features to avoid from false alarm • Walking test for each zone • Bypassing each zone manually or automatically Outputs • 1 siren output - Negative or positive trigger - Adjusting cut off time between 2 to 255 min • 3 programmable outputs - Can be increased to 8 PGM outputs with optional PGM relay module - Can be used as siren output - Can be used as arm output - Can be used as fire siren output - Can be used as being active when determined zones are armed www.teknim.com | [email protected] 4 Partitions • Arming/disarming each partition together or separately • Smart Partition Technology; zones are automatically assigned to the related partitions • Using each partition as independent systems (keypad, zone, phone numbers, siren, users can be assigned independently) 4 Keypads Connection • Each keypad has its own address. Keypads do not affect each other • Connecting LED and LCD keypads to the panel separately or together • Showing the motions only in specific zones by assigned partitions to the keypads • One key quick arming, partial arming (away, home, doors, windows... etc.) for each partition, by four special keys on the keypads • Producing warning sound (chime) by buzzer, when the specific zones become active or inactive • Automatic light activation of the determined zones (For example; when user opens the door, the keypad automatically illuminates) Power Supply • Short circuit protected 12V output (total 2A) • Extra auxiliary power for the siren • Extra auxiliary power for the keypad • Current limited battery charge circuit • Continuously mains power and battery check 256 event log memory with date and time information Communication by PC • Reading, setting and controlling all panel settings and reading event log memory from a local PC via optional link modules VPL232, VPL-USB; from a remote PC via onboard modem or from local network/internet via optional network module VPL-NET by using VAPMAN Alarm Management Software • Monitoring (zone, PGM or panel status) and controlling (arming/disarming, controlling of PGM outputs) panel from local PC via optional link modules VPL-232, VPL-USB, from remote PC via onboard modem or local network/internet via optional network module VPL-NET by using VAPMAN alarm management software Controlling remotely by phone • Arming/disarming of the panel • Controlling of PGM outputs • Getting information about panel status or PGM status Communicator • Including Contact ID and SIA formats • Calling 6 different private phone numbers (users) - Ability to deliver standard alarm warning signal - Ability to deliver voice message on any alarm by voice recording module VAV-210 or voice message module VAV- 218 • Calling 2 different central stations with secondary numbers • One key confirmation on incoming calls • Selecting communicator messages • Events which will be sent to the private phones can be selected • Sending delayed power failure report • Continuously telephone line check and alarms on lined failure • Distributing each private phone numbers and CMS numbers for related partitions Users • Installer code: Able to command all settings related with installation • Master code: Able to command all settings related with users (Code, time setting... etc) • 27 user codes: Able to command arming/disarming of the panel - User authorization can be limited for determined time and operation • Temporary guest code: Has normal user rights for a day or one time usage • Duress code: Able to disarm the panel but the central stations and users are called • PC access code: Able to control the panel via VAPMAN management software Arming/disarming alternatives • Partial arming/disarming • Automatic arming/disarming for a determined date and time period • Arming/disarming by remote controller • Arming/disarming by phone • Arming/disarming by VAPMAN alarm management software • Inactivity arming within entered time period Conventional Fire Alarm Systems - Can be adjusted to output randomly - Can be used as selectable trouble output - Can be used as smoke detector power (for automatic resetting) Intruder Alarm Sytems Alarm Panels 2 periodic timers • Can be used to control PGMs for determined hours and days Additional and optional modules • 4 zone expansion module (VAG-204) • Voice recording module (VAV-210) • 4 PGM relay module (TRM-904) • Network module (TPL-NET) • RS 232 Serial Communication Module (VPL-232) • USB Serial Communication Module (VPL-USB) • Remote control module (VAR-145) Keypad access limitation • As showing only determined partitions • As arming • As disarming • As accessing the programming Access control system • Using panel as an access control system for a door by connecting additional keypad to the door and assigning one user password and one PGM • Limiting access for determined date and time period Recommended keypads • VPC-350 Touch Screen keypad • VPC-301 LCD keypad • VPC-132 LED keypad • VPC-116 LED keypad (in the use of double zone feature, only supported zones can be seen) www.teknim.com | [email protected] 7 Alarm Panels Intruder Alarm Sytems VAP-408 M / P Alarm Panel VAP-408 Alarm Control Panel is the perfect high-end security and automation solution for medium and large sized residential and commercial areas. It is not only an alarm panel but also an automation system with 3 PGM outputs and periodic timers. Users may activate an electronic system such as irrigation system, air-condition, oven etc. in a determined time period by using PGM output. Users may arm/disarm panel and control PGM outputs remotely by phone. VAP-408 Alarm Control Panel can be controlled and monitored locally or remotely from a local PC or network/internet PC via VAPMAN Alarm Conventional Fire Alarm Systems Management Software. Its easy installation and user-friendly usage make it attractive both for installers and end users. M: Metal box / P: Plastic box General Features 8 + 8 zones • 8 zones on main control panel, expandable to 12 zones with optional zone expansion module and to 16 zones with hardwire zone-doubling • Using each zone with NC or NO contacts devices with or without EOL resistors • Selecting each zone as 12 different type (door, window, home, away, 24 hours, fire, tamper, panic…etc.) • Entry/Exit delays for each partition • Adjustable zone response speed • Additional features of the zones (Entry/exit zone, follower zone, last-door zone, zone with audio / silent…etc.) • Arming panel automatically without delay time by determining Entry/Exit zones, when someone exits from last-door • Adjusting each zone as special zone in order to transmit alarm message to the central station without alarm siren (for gas detectors, flood detectors) • Selectable cross zone and double hit features to avoid from false alarm • Walking test for each zone • Bypassing each zone manually or automatically Outputs • 1 siren output - Negative or positive trigger - Adjusting cut off time between 2 to 255 min • 3 programmable outputs -Can be increased to 8 PGM outputs with optional PGM relay module - Can be used as siren output - Can be used as arm output - Can be used as fire siren output - Can be used as being active when determined zones are armed - Can be adjusted to output randomly - Can be used as selectable trouble output - Can be used as smoke detector power (for automatic resetting) 8 - Can be used as being active when there is a motion in determined zones or partitions - Can be used as being active in assigned time period - Can be used as magnetic or electro mechanic door lock controller output when using access control feature 4 Partitions • Arming/disarming each partition together or separately • Smart Partition Technology; zones are automatically assigned to the related partitions • Using each partition as independent systems (keypad, zone, phone numbers, siren, users can be assigned independently) 4 Keypads Connection • Each keypad has its own address. Keypads do not affect each other • Connecting LED and LCD keypads to the panel separately or together • Showing the motions only in specific zones by assigned partitions to the keypads • One key quick arming, partial arming (away, home, doors, windows... etc.) for each partition, by four special keys on the keypads • Producing warning sound (chime) by buzzer, when the specific zones become active or inactive • Automatic light activation of the determined zones (For example; when user opens the door, the keypad automatically illuminates) Power Supply • Short circuit protected 12V output (total 1A) • Extra auxiliary power for the siren • Extra auxiliary power for the keypad • Current limited battery charge circuit • Continuously mains power and battery check 256 event log memory with date and time information Communication by PC • Reading, setting and controlling all panel settings and reading event www.teknim.com | [email protected] Alarm Panels Communicator • Including Contact ID and SIA formats • Calling 6 different private phone numbers (users) - Ability to deliver standard alarm warning signal - Ability to deliver voice message on any alarm by voice recording module VAV-210 or voice message module VAV- 218 • Calling 2 different central stations with secondary numbers • One key confirmation on incoming calls • Selecting communicator messages • Events which will be sent to the private phones can be selected • Sending delayed power failure report • Continuously telephone line check and alarms on lined failure • Distributing each private phone numbers and CMS numbers for related partitions Users • Installer code: Able to command all settings related with installation • Master code: Able to command all settings related with users (Code, time setting... etc) • 9 user codes: Able to command arming/disarming of the panel - User authorization can be limited for determined time and operation • Temporary guest code: Has normal user rights for a day or one time usage • Duress code: Able to disarm the panel but the central stations and users are called Arming/disarming alternatives • Arming/disarming by a key • Partial arming/disarming • Automatic arming/disarming for a determined date and time period • Arming/disarming by remote controller • Arming/disarming by phone • Arming/disarming by VAPMAN alarm management software • Inactivity arming within entered time period 2 periodic timers • Can be used to control PGMs for determined hours and days. Additional and optional modules • 4 zone expansion module (VAG-204) • Voice recording module (VAV-210) •4 PGM relay module (TRM-904) • Network module (TPL-NET) • RS 232 Serial Communication Module (VPL-232) • USB Serial Communication Module (VPL-USB) • Remote control module (VAR-145) Keypad access limitation • As showing only determined partitions • As arming • As disarming • As accessing the programming Intruder Alarm Sytems Controlling remotely by phone • Arming/disarming of the panel • Controlling of PGM outputs • Getting information about panel status or PGM status • PC access code: Able to control the panel via VAPMAN management software Conventional Fire Alarm Systems log memory from a local PC via optional link modules VPL-232, VPL-USB; from a remote PC via onboard modem or from local network/internet via optional network module VPL-NET by using VAPMAN Alarm Management Software • Monitoring (zone, PGM or panel status) and controlling (arming/disarming, controlling of PGM outputs) panel from local PC via optional link modules VPL-232, VPL-USB, from remote PC via onboard modem or local network/internet via optional network module VPL-NET by using VAPMAN alarm management software Access control system • Using panel as an access control system for a door by connecting additional keypad to the door and assigning one user password and one PGM • Limiting access for determined date and time period. Recommended keypads • VPC-350 Touch Screen keypad • VPC-301 LCD keypad • VPC-116 LED keypad • VPC-108 LED keypad (in the use of double zone feature, only supported zones can be seen) All Teknim Alarm Panels connect to a central monitoring station (CMS) or defined users via landline phone. In case of alarm, communicator delivers event codes with Contact ID protocol to CMS and standart alarm warning signal to defined users, at the same time. Advanced built-in dialer By using optional Voice Recording Module* users can record their own voice and recieve this recorded message instead of standart alarm warning signal. On VAP-400 series alarm panels, users have the ability to dial the alarm panel via its phone line during an event or any regular time they want. Just by pressing on buttons of the phone, users can arm/disarm the panel or manage the programmable outputs. * For more information please refer to page www.teknim.com | [email protected] 9 Alarm Panels Conventional Fire Alarm Systems Intruder Alarm Sytems Especially for small sized residental areas, selecting smart partition feature, zones are automatically assigned to the related partitions as windows, doors, home & away. With one key quick arming you can arm/disarm your system compeletely or partially (away, home, doors, windows...etc.) by four special keys on the keypads. A (home) B (windows) C (doors) D (away) VAP-404 M / P Smart partitioning technology Alarm Panel VAP-404 Alarm Control Panel is the perfect security solution for small and medium sized residential and commercial areas. It is not only an alarm panel but also an automation system with 2 PGM outputs and periodic timers. Users may activate an electronic system such as irrigation system, aircondition, oven etc. in a determined time period by using PGM output. Users may arm/disarm panel and control PGM outputs remotely by phone. VAP-404 Alarm Control Panel can be controlled and monitored locally or remotely from a local PC or network/internet PC via VAPMAN Alarm Management Software. Its easy installation and user-friendly usage make it attractive both for installers and end users. M: Metal box / P: Plastic box General Features 4 + 4 zones • 4 zones on main control panel, expandable to 8 zones with hardwire zone-doubling or optional zone expansion module • Using each zone with NC or NO contacts devices with or without EOL resistors • Selecting each zone as 12 different type (door, window, home, away, 24 hours, fire, tamper, panic…etc.) • Entry/Exit delays for each partition • Adjustable zone response speed • Additional features of the zones (Entry/exit zone, follower zone, last-door zone, zone with audio / silent…etc.) • Arming panel automatically without delay time by determining Entry/Exit zones, when someone exits from last-door • Adjusting each zone as special zone in order to transmit alarm message to the central station without alarm siren (for gas detectors, flood detectors) • Selectable cross zone and double hit features to avoid from false alarm • Walking test for each zone • Bypassing each zone manually or automatically 10 Outputs • 1 siren output - Negative or positive trigger - Adjusting cut off time between 2 to 255 min • 2 programmable outputs - Can be increased to 8 PGM outputs with optional PGM relay module. - Can be used as siren output - Can be used as arm output - Can be used as fire siren output - Can be used as being active when determined zones are armed - Can be adjusted to output randomly - Can be used as selectable trouble output - Can be used as smoke detector power (for automatic resetting) - Can be used as being active when there is a motion in determined zones or partitions - Can be used as being active in assigned time period - Can be used as magnetic or electro mechanic door lock controller output when using access control feature • 1 armed output www.teknim.com | [email protected] 1 key Input • Being armed in toggle or level mode 4 Partitions • Arming/disarming each partition together or separately • Smart Partition Technology; zones are automatically assigned to the related partitions • Using each partition as independent systems (keypad, zone, phone numbers, siren, users can be assigned independently) 4 Keypads Connection • Each keypad has its own address. Keypads do not affect each other • Connecting LED and LCD keypads to the panel separately or together • Showing the motions only in specific zones by assigned partitions to the keypads • One key quick arming, partial arming (away, home, doors, windows... etc.) for each partition, by four special keys on the keypads • Producing warning sound (chime) by buzzer, when the specific zones become active or inactive • Automatic light activation of the determined zones (For example; when user opens the door, the keypad automatically illuminates) Power Supply • Short circuit protected 12V output (total 1A) • Extra auxiliary power for the siren • Extra auxiliary power for the keypad • Current limited battery charge circuit • Continuously mains power and battery check • One key confirmation on incoming calls • Selecting communicator messages • Events which will be sent to the private phones can be selected • Sending delayed power failure report • Continuously telephone line check and alarms on lined failure • Distributing each private phone numbers and CMS numbers for related partitions Users • Installer code: Able to command all settings related with installation • Master code: Able to command all settings related with users. (Code, time setting... etc) • 5 user codes: Able to command arming/disarming of the panel. - User authorization can be limited for determined time and operation • Temporary guest code: Has normal user rights for a day or one time usage • Duress code: Able to disarm the panel but the central stations and users are called • PC access code: Able to control the panel via VAPMAN management software Arming/disarming alternatives • Arming/disarming by a key • Partial arming/disarming • Automatic arming/disarming for a determined date and time period • Arming/disarming by remote controller • Arming/disarming by phone • Arming/disarming by VAPMAN alarm management software • Inactivity arming within entered time period Conventional Fire Alarm Systems - Being active or inactive when the assigned partitions armed. Intruder Alarm Sytems Alarm Panels 2 periodic timers • Can be used to control PGMs for determined hours and days 256 event log memory with date and time information. Communication by PC • Reading, setting and controlling all panel settings and reading event log memory from a local PC via optional link modules VPL232, VPL-USB; from a remote PC via optional modem module TPL-MDM or from local network/internet via optional network module TPL-NET by using VAPMAN Alarm Management Software • Monitoring (zone, PGM or panel status) and controlling (arming/disarming, controlling of PGM outputs) panel from local PC via optional link modules VPL-232, VPL-USB, from remote PC via optional modem module TPL-MDM or local network/internet via optional network module TPL-NET by using VAPMAN alarm management software Controlling remotely by phone • Arming/disarming of the panel • Controlling of PGM outputs • Getting information about panel status or PGM status Communicator • Including Contact ID, DTMF 3+1, 3+2, 4+1, 4+2 formats • Calling 6 different private phone numbers (users) - Ability to deliver standard alarm warning signal - Ability to deliver voice message on any alarm by voice recording module VAV-210 or voice message module VAV- 218 • Calling 2 different central stations with secondary numbers Additional and optional modules • 4 zone expansion module (VAG-204) • Voice recording module (VAV-210) • 4 PGM relay module (TRM-904) • Network module (TPL-NET) • RS 232 Serial Communication Module (VPL-232) • USB Serial Communication Module (VPL-USB) • Remote control module (VAR-145) • Modem Module (TPL-MDM) Keypad access limitation • As showing only determined partitions • As arming • As disarming • As accessing the programming Access control system • Using panel as an access control system for a door by connecting additional keypad to the door and assigning one user password and one PGM • Limiting access for determined date and time period. Recommended keypads • VPC-350 Touch Screen keypad • VPC-301 LCD keypad • VPC-108 LED keypad www.teknim.com | [email protected] 11 Alarm Panels Intruder Alarm Sytems VAP-308 M / P Alarm Panel VAP-308 Alarm Control Panel is the perfect security solution for medium and large sized residential and commercial areas. It is not only an alarm panel but also an automation system with PGM output and periodic timers. Users may activate an electronic system such as irrigation system, aircondition, oven etc. in a determined time period by using PGM output. VAP308 Alarm Control Panel can be controlled and monitored locally or remotely from a local PC or network/internet PC via VAPMAN Alarm Management Software. Its easy installation and user-friendly usage make it Conventional Fire Alarm Systems attractive both for installers and end users. M: Metal box / P: Plastic box General Features 8 + 8 zones • 8 zones on main control panel, expandable to 12 zones with optional zone expansion module and to 16 zones with hardwire zone-doubling • Using each zone with NC or NO contacts devices with or without EOL resistors • Selecting each zone as 12 different type (door, window, home, away, 24 hours, fire, tamper, panic…etc.) • Entry/Exit delays for each partition • Adjustable zone response speed • Additional features of the zones (Entry/exit zone, follower zone, last door zone, zone with audio / silent…etc.) • Arming panel automatically without delay time by determining Entry/Exit zones, when someone exits from last-door • Adjusting each zone as special zone in order to transmit alarm message to the central station without alarm siren (for gas detectors, flood detectors) • Selectable cross zone and double hit features to avoid from false alarm • Walking test for each zone • Bypassing each zone manually or automatically Outputs • 1 siren output - Negative or positive trigger - Adjusting cut off time between 2 to 255 min • 1 programmable output - Can be used as siren output - Can be used as arm output - Can be used as fire siren output - Can be used as selectable trouble output - Can be used as smoke detector power (for automatic resetting) - Can be used as being active when there is a motion in determined zones - Can be used as being active in assigned time period 12 2 Keypads can be connected • Each keypad has its own address. Keypads do not affect each other • Connecting LED and LCD keypads to the panel separately or together • Producing warning sound (chime) by buzzer, when the specific zones become active or inactive • Automatic light activation of the determined zones (For example; when user opens the door, the keypad automatically illuminates) Power Supply • Short circuit protected 12V output (total 1A) • Extra auxiliary power for the siren • Extra auxiliary power for the keypad • Current limited battery charge circuit • Continuously mains power and battery check 256 event log memory with date and time information. Communication by PC • Reading, setting and controlling all panel settings and reading event log memory from a local PC via optional link modules VPL-232, VPLUSB; from a remote PC via optional modem module TPL-MDM or from local network/internet via optional network module TPL-NET by using VAPMAN Alarm Management Software • Monitoring (zone, PGM or panel status) and controlling (arming/disarming, controlling of PGM outputs) panel from local PC via optional link modules VPL-232, VPL-USB, from remote PC via optional modem module VPL-MDM or local network/internet via optional network module VPL-NET by using VAPMAN alarm management software Communicator • Including Contact ID , DTMF 3+1, 3+2, 4+1, 4+2 formats • Calling 6 different private phone numbers (users) - Ability to deliver standard alarm warning signal - Ability to deliver voice message on any alarm by voice recording module VAV-210 or voice message module VAV-218 www.teknim.com | [email protected] Alarm Panels Arming/disarming alternatives • Arming/disarming by a key • Automatic arming/disarming for a determined date and time period • Arming/disarming by remote controller 2 weekly timers • Can be used to control PGMs Additional and optional modules • 4 zone expansion module (VAG-204) • Voice recording module (VAV-210) • RS 232 Serial Communication Module (VPL-232) • USB Serial Communication Module (VPL-USB) • Network module (TPL-NET) • Modem Module (TPL-MDM) • Remote control module (VAR-145) Recommended keypads • VPC-301 LCD keypad • VPC-016 LED keypad • VPC-116 LED keypad • VPC-108 LED keypad (in the use of double zone feature only supported zones can be seen) • VPC-104 LED keypad (in the use of double zone feature, only supported zones can be seen) Intruder Alarm Sytems Users • Installer code: Able to command all settings related with installation • Master code: Able to command all settings related with users. (code, time setting.. etc) • 9 user codes: Able to command arming/disarming of the panel. - User authorization can be limited for determined time and operation • Temporary guest code: Has normal user rights for a day or one time usage • Duress code: Able to disarm the panel but the central stations and users are called • PC access code: Able to control the panel via VAPMAN management software • Arming/disarming by VAPMAN alarm management software • Inactivity arming within entered time period Conventional Fire Alarm Systems • Calling a central station with secondary number • Selecting communicator messages • Selecting events which will be sent to the private phones • Delayed power failure report Life saving DURESS CODE What if someone follows you up to your house and forces you to disable your burglar alarm system? When you dial the duress code, your home security system disarms as usual but at the same time it sends a silent alarm to the central monitoring station, advising that you are in duress. Since central monitoring station is notified about the type of alarm which is activated, they take the duress alarm with even more intensity than a regular alarm. General features of Teknim Alarm Panels: Arming/disarming the panel via phone/PC. Getting information about panel status or PGM status, remotely by phone/PC. t Automatic arming/disarming for a determined time period. t Using outdoor siren as a warning system with high sound level and flasher. t Alarm panel may also run a fire alarm panel with smoke detectors*. t Via a local or remote PC, users can control and observe all panel settings, monitor all panel status. t Users can be allowed or/and restricted on specified; -Keypads, -Date/time periods, -Partitions, -Operations (arm, disarm, bypass) t t * Please refer to page 34. www.teknim.com | [email protected] 13 Alarm Panels Intruder Alarm Sytems VAP-304 M / P Alarm Panel VAP-304 Alarm Control Panel is the perfect security solution for small and medium sized residential and commercial areas. It is not only an alarm panel but also an automation system with PGM output and periodic timers. Users may activate an electronic system such as irrigation system, aircondition, oven etc. in a determined time period by using PGM output. VAP304 Alarm Control Panel can be controlled and monitored locally or remotely from a local PC or network/internet PC via VAPMAN Alarm Management Software. Its easy installation and user-friendly usage make it Conventional Fire Alarm Systems attractive both for installers and end users. M: Metal box / P: Plastic box General Features 4 + 4 zones • 4 zones on main control panel, expandable to 8 zones with hardwire zone-doubling or optional zone expansion module • Using each zone with NC or NO contacts devices with or without EOL resistors • Selecting each zone as 12 different type (door, window, home, away, 24 hours, fire, tamper, panic…etc.) • Entry/Exit delays for each partition • Adjustable zone response speed • Additional features of the zones (Entry/exit zone, follower zone, last-door zone, zone with audio / silent…etc.) • Arming panel automatically without delay time by determining Entry/Exit zones, when someone exits from last-door • Adjusting each zone as special zone in order to transmit alarm message to the central station without alarm siren (for gas detectors, flood detectors) • Selectable cross zone and double hit features to avoid from false alarm • Walking test for each zone • Bypassing each zone manually or automatically Outputs • 1 siren output - Negative or positive trigger - Adjusting cut off time between 2 to 255 min • 1 programmable output - Can be used as siren output - Can be used as arm output - Can be used as fire siren output - Can be used as selectable trouble output - Can be used as smoke detector power (for automatic resetting) - Can be used as being active when there is a motion in determined zones - Can be used as being active in assigned time period Power Supply • Short circuit protected 12V output (total 1A) 14 • Extra auxiliary power for the siren • Extra auxiliary power for the keypad • Current limited battery charge circuit • Continuously mains power and battery check 256 event log memory with date and time information Communication by PC • Reading, setting and controlling all panel settings and reading event log memory from a local PC via optional link modules VPL232, VPL-USB; from a remote PC via optional modem module TPLMDM or from local network/internet via optional network module TPL-NET by using VAPMAN Alarm Management Software • Monitoring (zone, PGM or panel status) and controlling (arming/disarming, controlling of PGM outputs) panel from local PC via optional link modules VPL-232, VPL-USB, from remote PC via optional modem module TPL-MDM or local network/internet via optional network module TPL-NET by using VAPMAN alarm management software Communicator • Including Contact ID , DTMF 3+1, 3+2, 4+1, 4+2 formats • Calling 6 different private phone numbers (users) - Ability to deliver standard alarm warning signal - Ability to deliver voice message on any alarm by voice recording module VAV-210 or voice message module VAV-218 • Calling a central station with secondary number • Selecting communicator messages • Selecting events which will be sent to the private phones • Delayed power failure report Users • Installer code: Able to command all settings related with installation. • Master code: Able to command all settings related with users (code, time setting.. etc) • 5 user codes: Able to command arming/disarming of the panel -User authorization can be limited for determined time and www.teknim.com | [email protected] Alarm Panels Intruder Alarm Sytems Arming/disarming alternatives • Arming/disarming by a key • Automatic arming/disarming for a determined date and time period • Arming/disarming by remote controller • Arming/disarming by VAPMAN alarm management software • Inactivity arming within entered time period Additional and optional modules • 4 zone expansion module (VAG-204) • Voice recording module (VAV-210) • RS 232 Serial Communication Module (VPL-232) • USB Serial Communication Module (VPL-USB) • Network module (TPL-NET) • Modem module (TPL-MDM) • Remote control module (VAR-145) Recommended keypads • VPC-301 LCD keypad • VPC-108 LED keypad • VPC-104 LED keypad 2 weekly timers • Can be used to control PGMs Features Zone+Zone doubling EOL resistor connection Connection option (NC,NO) Zone determination (fire, 24 hours, tamper...etc) Cross Zone and Double hit Walking Test Adjustable zone detection time Restriction of user authorization Programmable outputs Arm output Key Input Partition Smart Partition Technology (SPT) Partial arming Entry/Exit delays for each partition Automatic and manual by-pass Supported keypad connection Event log memory Line input /phone output Remotely control by phone Communicator Dialer Supported communication format User codes including master, installer, and PC access code Duress and Guest codes Time managed arming/disarming Arming/disarming by a key Partition management by a key Event code selection for communicator Access control system Remotely upload and download Monitoring and control from internet VAPMAN Alarm Management Software NC/NO options for siren and PGM outputs Continuously mains power and battery and check Continuously phone line check Voice recording module Remote controlling module Zone expansion module 4 PGM Relay Module PC link modules (RS232, USB) Network module Modem module Wireless Zone Module Adjustable siren cut off time VAP-304 P/M VAP-308 P/M VAP-404 P/M 4+4 8+8 4+4 0,1 or 2 0,1 or 2 0,1 or 2 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 1 1 2 with PGM with PGM Yes No No Yes 1 1 4 No No Yes No No Yes No No Yes Yes Yes Yes 2 2 4 256 256 256 Yes Yes Yes No No Yes Yes Yes Yes Yes Yes Yes Contact ID, DTMF 3+1, 3+2, 4+1, 4+2 8 12 8 VAP-408 P/M Yes Yes Yes No Yes No Optional Optional Standard Yes Yes No Optional Optional +4(optional) No Optional Optional No Optional Yes Yes Yes Yes Yes Yes Yes Standard Optional Standard Yes Yes Yes Optional Optional +4(optional) Optional Optional Optional On board Optional Yes Yes Yes Yes No Yes No Optional Optional Standard Yes Yes No Optional Optional +4(optional) No Optional Optional Optional Optional Yes Yes Yes Yes Yes Yes Yes Optional Optional Standard Yes Yes Yes Optional Optional +4(optional) Optional Optional Optional Optional Optional Yes www.teknim.com | [email protected] VAP-416 16+16 8+8 0,1 or 2 0,1 or 2 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 3 3 with PGM with PGM No No 4 4 Yes Yes Yes Yes Yes Yes Yes Yes 4 4 256 256 Yes Yes Yes Yes Yes Yes Yes Yes Contact ID and SIA 32 12 Conventional Fire Alarm Systems operation • Temporary guest code: Has normal user rights for a day or one time usage • Duress code: Able to disarm the panel but the central stations and users are called • PC access code: Able to control the panel via VAPMAN management software Yes Yes Yes Yes Yes Yes Standard Optional Standard Yes Yes Yes Optional Optional +4(optional) Optional Optional Optional On board Optional Yes 15 Alarm Keypads Conventional Fire Alarm Systems Intruder Alarm Sytems VPC-301B LCD Alarm Keypad VPC-301 LCD Keypad has been designed to control all VAP series alarm panels. It can be adopted to all decorations with its esthetic design. t Programmable zone names t Smoke detector reset connected to the PGM by keypad t Backlit, two lines, 32 character LCD screen t Special keys for panic, fire and duress alarm t Adopted with all VAP Series Panels. It can be used with t Energy saving mode for energy cutting other VAP series keypads t Backlit, multi-functional silicone keys t Backlighting boost t 4 special buttons for each partition for quick & partial arm with backlight and activation light t Internal buzzer t Ability to read event log t Automatic key light when a motion detected in a determined zone t Chime feature (warning with sound and light when the determined zones active or inactive) t Auto protection for wrong passwords entered 5 times. VPC-132 t Sabotage switch (no need additional cable) t On screen programming t Alternately on screen thermometer/time/date and auxiliary texts t Easy programming by menu system t Multi-language support t Menu system, short keys and direction keys for easy programming t Two different keypad lights: Green (standard), Blue (optional) LED Alarm Keypad VPC-132 thirty two-zone is esthetic and smart LED keypad has been designed to control VAP series alarm panels. It is possible to control all features of VAP series alarm panels by VPC-132. t Backlit, multi-functional silicone keys t Energy saving mode for mains failure t Adopted with all VAP Series Panels with 4-32 zones. It t Automatic key light when a motion detected in a determined can be used with other VAP series keypads (except VPC104 and VPC-016) at the same panel t Backlit 4 partition zone designed for partial arm with a key t Different led for each zone t Internal buzzer t Ability to read event log t Special keys for panic, fire and duress alarm 16 zone t Chime feature (warning with sound and light when the determined zones active or inactive) t Auto protection for wrong passwords entered 5 times t Smoke detector reset connected to the PGM by keypad t Sabotage switch (no need additional cable) t Easy programming features t Two different keypad light: Green (standard), blue (optional) www.teknim.com | [email protected] Alarm Keypads LED Alarm Keypad Intruder Alarm Sytems VPC-116 sixteen-zone is esthetic and smart LED keypad has been designed to control all features of VAP series alarm panels with 4-16 zones. t Backlit, multi-functional silicone keys t Energy saving mode for mains failure t Adopted with all VAP Series Panels with 4-16 zones. It t Automatic key light when a motion detected in a determined can be used with other VAP series keypads (except VPC104) at the same panel t Backlit 4 partition zone designed for partial arm with a key t Different led for each zone t Internal buzzer t Ability to read event log t Special keys for panic, fire and duress alarm zone t Chime feature (warning with sound and light when the determined zones active or inactive) t Auto protection for wrong passwords entered 5 times t Smoke detector reset connected to the PGM by keypad t Sabotage switch (no need additional cable) t Easy programming features t Two different keypad light Green (standard), blue (optional) VPC-108 Conventional Fire Alarm Systems VPC-116 LED Alarm Keypad VPC-108 eight-zone is esthetic and smart LED keypad has been designed to control VAP series alarm panels with 4 to 8 zones. t Backlit, multi-functional silicone keys t Energy saving mode for mains failure t Adopted with all VAP Series Panels have 4-8 zones. It t Automatic key light when a motion detected in a determined can be used with other VAP series keypads (except VPC104) at the same panel t Backlit 4 partition zone designed for partial arm with a key t Different led for each zone t Internal buzzer t Ability to read event log t Special keys for panic, fire and duress alarm zone t Chime feature (warning with sound and light when the determined zones active or inactive) t Auto protection for wrong passwords entered 5 times t Smoke detector reset connected to the PGM by keypad t Sabotage switch (no need additional cable) t Easy programming features t Two different keypad light Green (standard), blue (optional) www.teknim.com | [email protected] 17 Alarm Keypads Conventional Fire Alarm Systems Intruder Alarm Sytems VPC-104 LED Alarm Keypad VPC-104 eight-zone, functional, smart and economic LED keypad have been designed to control all features of the VAP-304 Alarm Panel. t Backlit, multi-functional silicone keys. t 7 segment red screens display the moving zones and messages t Internal buzzer t Ability to read event log t Special keys for panic, fire and duress alarm t Energy saving mode for mains failure t Automatic key light when a motion detected in a determined zone t Chime feature (warning with sound and light when the determined zones active or inactive) t Auto protection for wrong passwords entered 5 times t Smoke detector reset connected to the PGM by keypad t Sabotage switch (no need additional cable) t Easy programming features Features VPC-104 VPC-108/116/132 VPC-301 Backlit, two lines, 32 character LCD screen Backlit, long lived silicone keys Backlighting boost Back lighted 4 partition zone designed for partial arm with a key Internal buzzer Automatic key light when a motion detected in a determined zone Chime feature (warning with sound and light when the determined zones active or inactive) Special keys for panic, fire and duress alarm Energy saving mode Easy programming by menu system Multi-language support On screen thermometer/time/date Auto protection for wrong passwords entered 5 times 7 Segment LED screen No Yes No No Yes No Yes Yes Yes No No No Yes Yes No Yes No Yes Yes Yes Yes Yes Yes No No No Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No Plain, competible and user friendly design t Backlit, long lived silicone keys t Easy programming t Internal buzzer t Chime feature t Special keys for panic, fire and duress alarm t Energy saving mode for energy cuttings t Sabotage switch t Auto-protection for wrong password entered 5 times t Ability to read event log t Automatic key light when a motion detected in a determined zone t Ability to reset smoke detector, connected to PGM outputs, through the keypad t Lead-free, durable plastic body 18 www.teknim.com | [email protected] NEW TLP-NET Network Module t TPLNET module supplies communication beetwen VAPMAN alarm management software and VAP series panels via network and ethernet port. § Detailed event log memory review § Monitoring and setting panel status online § Arming/disarming panel, controlling zones and PGMs t VAPMAN Alarm Management Software lets users and installers to control and set VAP Series Alarm Panels from a local/remote PC or internet via serial ports, modem or network... Be anywhere in the world, security of your property is at your fingertips... 19 Optional Modules Conventional Fire Alarm Systems Intruder Alarm Sytems VAPMAN Alarm Management Software Installers; t Accessing panel from a local/remote PC or internet by using remote access code and installer code t Making all installer settings which can be done with keypad. t Loading saved panel settings in their computer during installation t Saving settings of the installed panel to their computer, and when a problem occurs, they can reach necessary information easily. If necessary, corrupted settings can be re-load t Solving the panel troubles by remote communication. Saving customer details (For ex; name, phone, panel type…etc.) t Downloading event log (event log can be printed out or saved as .xls file) Master Users; t Accessing control panel from a local/remote PC or internet by using remote access code and master user code t Making all master user settings (time/date settings, keypad settings, user authorizations, user codes…etc) which can be done with keypad t Controlling the panel (arming/disarming panel, controlling PGMs, by-passing, testing siren, PGM, user/CMS phones …etc.) t Monitoring panel status online t Downloading event log (event log can be printed out or saved as .xls file) Users; t Accessing control panel from a local/remote PC or internet by using remote access code and user code t Controlling the panel according to authorization given by master user (Arming/disarming, controlling PGMs, by-passing, testing siren, PGM, user/CMS phones …etc.) t Monitoring panel status online according to authorization given by master user t Downloading event log (event log can be printed out or saved as .xls file) 20 www.teknim.com | [email protected] Optional Modules Alarm panel detects events, when users call in during the event by type of event that transmits voice messages as. Each event is recorded as a factory for the type of voice recording and can not be changed. TPL-MDM Modem Module TPL-MDM Modem Module supplies communication between all VAP series alarm panels and remote PC via PSTN port. Users can read, change and control all panel settings, read event log memory, monitor and control panel status from a remote PC by using VAPMAN alarm management software via TPL-MDM Modem Module. t Standard in VAP 408 and VAP 416 Alarm Panels and adopted with VAP 304, VAP 308 and VAP 404 Alarm Panels t 5V, 50mA power supplied from alarm panel Intruder Alarm Sytems Voice Message Module Conventional Fire Alarm Systems VAV-264 t 90 x 50 mm dimensions VPL-USB PC Link Module VPL-USB PC Link Module supplies communication between all VAP series alarm panels and local PC via USB port. Users can read, change and control all panel settings, read event log memory, monitor and control panel status from a local PC by using VAPMAN alarm management software via VPLUSB PC Link Module. t Adopted with all VAP series alarm panels t 5V, 20mA power supplied from alarm panel t 90 x 50 mm dimensions VAV-210 Voice Recording Module VAV-210 Voice Recording Module supplies to send recorded alarm message to the users during alarm instead of alarm warning signal. User can record an alarm message up to 20 sec by using microphone on the module. Since the message is recorded in the flash memory on the module, the recorded message is not deleted during power cut. t 20 sec. voice recording t Adopted with all VAP series alarm panels t 5V, 20mA power supplied from alarm panel t 90 x 50 mm dimensions www.teknim.com | [email protected] 21 Optional Modules Conventional Fire Alarm Systems Intruder Alarm Sytems TRM-904 PGM Relay Output Module TRM-904 PGM Relay Output Module supplies total 4 PGM Relay output for VAP 404, VAP 408 and VAP 416 alarm panels. This module ensures the same PGM features supplied by adopted alarm panels. t Adopted with VAP-404, VAP-408 and VAP-416 alarm panels t Using max. 2 modules in a panel and by this way; increasing total PGM output amount to 8 t 240V, 7A NC/NO relay contacts t 5V, 150mA power supplied from alarm panel t 90 x 50 mm dimensions VAG-204 4 Zones Expansion Module VAG-204 4 zones Expansion Module supplies 4 additional zones to VAP series alarm panels. This module ensures the same zone features supplied by any VAP series alarm panel. t Adopted with VAP-404, VAP-408 and VAP-416 alarm panels t Using max. 2 modules in a panel and by this way; increasing total PGM output amount to 8 t 240V, 7A NC/NO relay contacts t 5V, 150mA power supplied from alarm panel t 90 x 50 mm dimensions ATR-244 Wireless Receiver Module Developed for use VAP Series alarm panels with wireless detectors and keyfob remote controllers. Total 7 wireless devices are supported. t High reception sensitivity antenna t 433.92 MHz working frequency t Easy learn/erase operation t No external power required t Dimensions: 90x50mm ARC-844 Remote Control t Aesthetic design with 4 buttons (Arm home, arm away, disarm, panic) t 128 bit encrypted rolling code system t Customizable panic button t 433.92 MHz working frequency t Long life 12V, 27A type alkaline battery 22 www.teknim.com | [email protected] PIR Detectors ATP-570 Dual Technology Motion Detector t Fully digital 110 Top view 0 t Antimasking t And/or selection for alarm output t High RF immunity t Pulse count 0.3] R34[1 R60[15.0] R10[2.9] R16[4.9] t Suitable for ceiling, wall and corner fitting Side view t Tamper alarm output t Strong mounting foot 10[2.9] 16[4.9] t 3 color indicator 34[10.3] Intruder Alarm Sytems t Separate adjustable sensitivity for microwave and PIR 60[15.0] Technical Specifications Dual element, digital 10.525GHz 9-16VDC, 50mA@12V 15m@110° NC 30VDC, 0.2A max NC (cover open activated) Red, yellow and green (can be disabled) Average 20V/m (10 MHz - 2 GHz.) 0,3 1.5 m/sec. 2.1m %95 RH (maximum) -20C 60C (-4F 140F) 108 x 63 x 50 mm Conventional Fire Alarm Systems Infrared sensor Microwave sensor Power requirement Detection range Alarm output Tamper switch Activation LED RFI Immunity Detectable speed Mounting height Humidity Temperature Dimensions (W X H X D) ATP-540 SERIES PIR DETECTORS Quality is in details... t Lead-free plastic material Sensitivity adjustment by trimpot; you are not limited to choose only high or low sensitivity range, also any desired sensitivity ranges can be choosen t Solid-state relay module; no moving parts inside so that has excellent advantages, such as; unlimited operating life, consumes lower current, no possibility of tricking with external factors such as magnet t As a result of very careful and hard R&D works; has excellent reliable software which prevents false alarm, protect sensitivity perfectly t t German-made digital sensor Electronic board; manufactured with SMD technology, gold-plated, lead-free, double-layered t Lens; HDPE material, with UV filtration, secured by a patent, USA-made, with 14m@110° detection range t t 1/2/3 selectable pulse count www.teknim.com | [email protected] 23 PIR Detectors ATP-540LR Long Range Digital PIR Detector Intruder Alarm Sytems t Digital signal processing by microcontroller t 20m long range t Dual element digital sensor 75 t Ultra sensitive with 14 bit resulation 0 Top View t Smart algoritm against false alarm t Sensitivity adjustment by trimpot t Pulse count options (1/2/3) R1 .0] 3[4 t Suitable for ceiling, wall and corner fitting t Cable canals at back side .0] 3[7 R2 .2] [20 R40 R8[2.4] Side View t Tamper alarm output 8[2.4] Conventional Fire Alarm Systems t Strong mounting foot 13[4.0] 23[7.0] 40[20.2] Technical Specifications Infrared sensor Power requirement Current drain Detection range Alarm output Pulse count Sensitivity adjustment Tamper switch Activation LED RFI Immunity Detectable speed Mounting height Humidity Temperature Dimensions (W X H X D) ATP-540N Dual element, digital 9-16VDC, 12V 20mA, 12VDC 20m@75° NC 30VDC, 0.2A max 1/2/3 selectable By trimpot NC (cover open and wall removel activated) Red (can be disabled) Average 20V/m (10 MHz - 2 GHz.) 0,3 1.5 m/sec. 2.1m %95 RH (maximum) -20C 60C (-4F 140F) 108 x 63 x 50 mm Digital PIR Detector t Dual element digital sensor t Ultra sensitive with 14 bit resulation Top View 110 0 t Digital signal processing by microcontroller t Smart algoritm against false alarm t Sensitivity adjustment by trimpot t Suitable for ceiling, wall and corner fitting t Cable canals at back side 1.7] R38[1 R46[14] R11[3.3] R18[5.6] Side View t Tamper alarm output t Strong mounting foot 11[3.3] 18[5.6] 38[11.7] 46[14.0] Technical Specifications Infrared sensor Power requirement Current drain Detection range Alarm output Pulse count Sensitivity adjustment Tamper switch Activation LED RFI Immunity Detectable speed Mounting height Humidity Temperature Dimensions (W X H X D) 24 Dual element, digital 9-16VDC, 12V 20mA, 12VDC 14m@110° NC 30VDC, 0.2A max 1/2/3 selectable By trimpot NC (cover open and wall removel activated) Red (can be disabled) Average 20V/m (10 MHz - 2 GHz.) 0,3 1.5 m/sec. 2.1m %95 RH (maximum) -20C 60C (-4F 140F) 108 x 63 x 50 mm www.teknim.com | [email protected] PIR Detectors ATP-540P Pet Immune Digital PIR Detector t Ultra sensitive Top View t High false alarm sensibility 90 0 t Selectable pulse counts t Using without mounting foot because of pet immunity feature Suitable for ceiling, wall and corner fitting t Cable canals at back side t Tamper alarm output t Walking test R1 .0] 3[4 .0] 3[7 R2 .2] [10 R40 R8[2.4] Side View 8[2.4] 13[4.0] 23[7.0] 40[10.2] Technical Specifications Infrared sensor Power requirement Pet Immunity Current drain Detection range Alarm output Pulse count Sensitivity adjustment Tamper switch Activation LED RFI Immunity Detectable speed Mounting height Humidity Temperature Dimensions (W X H X D) ATP-105 Dual element, digital 9-16VDC, 12V Up to 18kg and 60cm 20mA, 12VDC 10m@90° NC 30VDC, 0.2A max 1/2/3 selectable By trimpot NC (cover open and wall removel activated) Red (can be disabled) Average 20V/m (10 MHz - 2 GHz.) 0,3 1.5 m/sec. 2.1m %95 RH (maximum) -20C 60C (-4F 140F) 108 x 63 x 50 mm Conventional Fire Alarm Systems t Digital technology Intruder Alarm Sytems t Temperature compansated Mounting Foot for ATP Series PIR Detectors t This strong mounting foot can be adopted all ATP Series PIR Detectors t It is designed to supply wall, corner and ceiling mounting options for installers t 45° left/right, 15° downward adjustment possible with 5° steps www.teknim.com | [email protected] 25 Smoke Detectors TFD-1450 Optical Smoke + Heat Intruder Alarm Sytems Multisensor Detector TFD-1450, is an Optical Smoke + Heat Multisensor were designed with precise CPU control and thermister detection. It is state of the art combination of 'Optical Smoke' and 'Fixed Temperature' ensures the best quality of heat detection in all environment. Detectors were engineered to the best quality and durability. They work perfectly with all intruder alarm control panels. t 4 wire model, NC relay output t Adaptive threshold algorithm, to prevent dust caused alarms Conventional Fire Alarm Systems t Durable sensor head, no need for replacement t Inludes microprocessor: High electromagnetic immunity, no false alarm, immune to all kinds of light source (Etc: Fluorescent labms) t Plastic, white housing high temperature endurable and fireproof polymeric material t Alarm indicator LED can be seen from all points of view (360°, continuosly emitting red light t Easy installation and maintenance t Sleek low-profile housing design t High quality and reliability guarenteed t Designed to comply with European and US standarts t Base Included TFD-1430 Technical Specifications Wire Operation voltage Alarm current Standby current Operation temperature Alarm temperature Relative humidity Installation method Dimensions Casing material Weight (base included) 4 wire NC relay output 12VDC 35mA 100µA max -10°C to 50°C 54°C 0% to 95%, no condensation or icing Ceiling mounted ø110, H:50mm Plastic, white 0,110kg Optical Smoke Detector TFD-1430, is an Optical Smoke Detector provides reliable early warning of intense fires with fast response by detection smoke particles. It has the function of dustproof, mothproof, and antielectromagnetic interference. It performs well in detecting visible smoke caused by hidden or bright fire. It is suitable for detecting smoke in houses, stores, hotels and warehouses, etc. Detectors were engineered to the best quality and durability. They work perfectly with all intruder alarm control panels. t 4 wire model, NC relay output t Adaptive threshold algorithm, to prevent dust caused alarms t Durable sensor head, no need for replacement t Inludes microprocessor: High electromagnetic immunity, no false alarm, immune to all kinds of light source (Etc: Fluorescent labms) t Plastic, white housing high temperature endurable and fireproof polymeric material t Alarm indicator LED can be seen from all points of view (360°, continuosly emitting red light t Easy installation and maintenance t Sleek low-profile housing design t High quality and reliability guarenteed t Designed to comply with European and US standarts t Base Included 26 Technical Specifications Wire Operation voltage Alarm current Standby current Operation temperature Detection range Relative humidity Installation method Dimensions Casing material Weight (base included) www.teknim.com | [email protected] 4 wire NC relay output 12VDC 60mA 100µA max -10°C to 50°C 2 60m @4m height 0% to 95%, no condensation or icing Ceiling mounted ø110, H:50mm Plastic, white 0,110kg Defeat the insidious enemies with Teknim TGD Series Gas Detectors... Every winter, hundreds of citizens get sick or die in our country, because of natural gas and carbonmonoxide poisoning. It is easier to take precautions instead of risking your life. Nothing is more valuable than your and your beloved one's lives... TGD-904 Carbonmonoxide Detector t Microprocessor design t Relay output t Highly stable detection feature t 8-24V DC t Automatic reset after alarm t Recommended for ceiling mounting t Internal 70dB siren t LED can be seen from all points of t Relay output view (360)° TGD-903 Conventional Fire Alarm Systems Intruder Alarm Sytems Gas Detectors Natural Gas Detector t Microprocessor design t Relay output t Highly stable detection feature t 8-24V DC t Automatic reset after alarm t Recommended for ceiling mounting t Internal 70dB siren t LED can be seen from all points of t Relay output view (360)° 27 NEW ATS-3232 Universal Adjustable Temperature Detector ATS series adjustable temperature detector is developed to warn/alarm if the measured temperature goes beyond determined limits and/or communicate with central monitoring station. It is compatible with all VAP series and other companies' alarm panels. Has 3 different modes; - When temperature goes over the determined value, - When temperature goes below the determined value, - When temperature goes beyond the upper an lower values. 4 Adjustable limit temperature range -32°C~ +32°C (with 1°C increments) 4 Three different working modes; over limit, under limit, outwindow mode (window can be adjusted ±1°C ~ ±8°C) 4 Ultra sensitive digital temperature sensor 4 Compatible with all VAP series and other brands' alarm panels 4 RS232 port to integrated automation systems 4 Activation LED 4 Strong body 4 Solid state relay 4 All settings can be done by DIP switches Technical Specifications Adjustable temperature limit Temperature tolerance Power supply Humidity Dimensions -32°C ~ +32°C Adjustable between ±1°C ~ ±8°C 9-16VDC 95% maximum 108x63x50mm Suitable to use in places that temperature value must stay between some specific limits for ex: cold stores, biochemistry laboratories, meat packing houses, food and beverage storages of markets...etc. 28 NEW TVSD-143 Tilt-Shock-Vibration(Seismic) Detector A unique product by pioneer of innovations, Teknim: Selectable 3 functions: Tilt, Shock, Vibration (Seismic): Tilt, Shock, Vibration (Seismic) Detector has 3 functions as given in its name: Tilt, shock and vibration (seismic). Either you can active one of these three functions, or you can active all three at the same time. Depending on where you want to use, it is up to you to choose. Vibration function can be used as a "Seismic Sensor" which provides warning when an earthquake occurs. You can adjust the sensitivities of Shock and Vibration funtions, based on where you want to use, that prevents unnecessary alarm situations. 4Shock: The alarm output is activated if the object is exposed to sudden impacts. With sensitivity adjustment, the alarm output is not activated if the intensity of the impact stays under the value, that specified by the user. 44Tilt: If the detector inclines more than 15° from its starting position (the position of the detector while switching "on") to any other positions, the alarm output is activated, until the position of the object is reverted to the starting position. Selectable 3 functions: Tilt, Shock, Vibration ology 15° 15° ALARM ALARM ic G n Electro echn t r o s n se ent m t s dju ut ty a ivi sit Sen tp u yo ela r NC 15° 15° ALARM ALARM "Displacement-Time" graph of the periodic oscillatory motion 444Vibration (Seismic): If the detector is exposed to a periodic or random oscillatory motion caused by an earthquake or a drill, the alarm output is activated, until the motion stops. Vibrational motion can be in all three axes (Seperately or combined). Technical Specifications Voltage Contacts Activation LED Output relay Acceleration sensitivity Working temperature Sampling time 8-15VDC, 50mA NC Red 30VDC, 100mA 0,625mg 0°C - 65°C 1000Hz 29 Conventional Fire Alarm Systems Intruder Alarm Sytems Outdoor Sirens Now, with metal or plastic internal cover options! VAS-740A / VAS-740A P Outdoor Siren t Walking LEDs with 6 super bright LEDs t Intelligent trigger system that no jumper setting t Internal or external power supply option during alarm t Intelligent tamper detection system on power line t Strong ABS housing with 3 mm thickness t Internal metal or plastic (optional) protection covers electronic circuit and components t Microprocessor controlled t Tamper protection for removal of the top cover from the body of the siren or removal of the siren from the wall t Strong LED strobe t Two different siren pattern t Automatic cut off with two option (3 or 10 min) t Internal rechargeble battery t Two different siren tone t Wide and smooth area for company logo t Easy mounting Technical Specifications Power requirement Frequency Sound level@1m Internal battery Current at EXT mode Current at INT mode Stand by current Dimensios (WxHxD) Weight 30 9-14VDC, Nominal 12VDC 1400-3000Hz 118dB max. 6V, 330mAh 300mA with flasher@12V 25mA@12V 25mA 215x300x60mm 1,354kg www.teknim.com | [email protected] Outdoor & Indoor Sirens t Strong ABS housing with 3 mm thickness t Internal metal or plastic (optional) protection covers electronic circuit and components t Microprocessor controlled t High sound level with piezo t Tamper protection for removal of the top cover from the body of the siren or removal of the siren from the wall t Strong strobe, sliding 2 leds t Auto-tamper t Automatic inactivation option of the siren t Internal rechargeable battery t Two different siren speeds t Suitable for both positive or negative trigger t Power voltage from battery or panel during alarm (SAB or SCB) t Negative tamper option t Wide and smooth area for company logo, easy mounting Technical Specifications Power requirement Frequency Sound level@1m Internal battery Current at SAB mode (@12V) Current at SCB mode (@12V) Strobe current (@12V) Stand by current (@12V) Strobe frequency (@12V) Dimensios (WxHxD) Weight 9-14VDC, Nominal 12VDC 1400-3000Hz 118dB max. 6V, 330mAh 200mA 25mA 100mA 10mA 1,0Hz 215x300x60mm 1,354kg Conventional Fire Alarm Systems Outdoor Siren Intruder Alarm Sytems VAS-720WR, VAS-720WB / VAS-720WR P, VAS-720WB P VAS-112B Outdoor Siren with Strobe t Strong ABS housing with 3 mm thickness t Supply voltage 8-16V DC (Nominal 12V) t Alarm current: 25mA@12V t Operational temperature range: -20°C - 70°C t Dimensions: Ø:110mm, h:50mm t Weight: 107g t Compatible with intruder alarm panels t 100dB sound level @1m distance (12V DC) t Blue-white, fire-proof ABS housing t Strobe: 6 super bright LEDs www.teknim.com | [email protected] 31 Continuous Power Supplies Conventional Fire Alarm Systems Intruder Alarm Sytems TPS-1201 12V Continuous Power Supply t 12V DC, 1A , switching (SMPS) t Used for Intruder Alarm Systems when additional power needed t Current limited battery charger t Short circuit protection, automatic resetable fuse t Dry contact relay for trouble condition t Dimensions: 30cm(H) x 21cm(W) x 8cm(D) t 230V, 25VA power input TPS-1202 12V Continuous Power Supply t 12V DC, 2A , switching (SMPS) t Used for Intruder Alarm Systems when additional power needed t Current limited battery charger t Short circuit protection, automatic resetable fuse t Dry contact relay for trouble condition t Dimensions: 30cm(H) x 21cm(W) x 8cm(D) t 230V, 35VA power input TPS-2401 24V Continuous Power Supply t 24V DC, 1A , switching (SMPS) t Used for Fire Alarm Systems when additional power needed t Current limited battery charger t Short circuit protection, automatic resetable fuse t Dry contact relay for trouble condition t Dimensions: 30cm(H) x 30cm(W) x 8cm(D) t 230V, 25VA power input TPS-2402 24V Continuous Power Supply t 24V DC, 2A , switching (SMPS) t Used for Fire Alarm Systems when additional power needed t Current limited battery charger t Short circuit protection, automatic resetable fuse t Dry contact relay for trouble condition t Dimensions: 30cm(H) x 30cm(W) x 8cm(D) t 230V, 35VA power input 32 www.teknim.com | [email protected] Can you risk your life, instead of taking the simplest precautions? CONVENTIONAL FIRE ALARM SYSTEMS Fire Alarm Panels TFP-908 / 916 / 924 / 932 Expandable Intruder Alarm Sytems Conventional Fire Alarm Panels Technical Specifications Zone number Number of detectors for each zone to be connected End of line resistor Power supply Power output Siren output Fire relay Conventional Fire Alarm Systems Trouble relay Battery Humidity Temperature Dimensions Weight LCD 8 / 16 / 24 / 32 30 (Teknim TF Series) 6,8kΩ 230V, 35VA with internal transformer 6-25VDC, 1A with automatic fuse 24VDC, 0,5A with automatic fuse, 6,8kΩ end of line resistor 30V 1A NC/NO dry contact, customizable according to alarm type 30V 1A NC/NO dry contact, customizable according to trouble type 2 pcs 12V 7Ah 95% RH (maximum) -10°C ~ 55°C (14°F ~ 131°F) 370x310x100mm 4kg x2 x100 PREALARM BYPASS t 24V, from 8 zone to 32 zone. Each type can expand up to 32 zones t Easy to use with large graphic LCD t Seperate status, alarm and trouble LEDs t Zone names can be entered t 100 pcs. event memory with date and time information t Night mode (automatic or manual) t Pre-alarm capability (can be set for each zone, can be cancelled from front panel) t Smart battery charger, long battery life (Able to see battery voltage on display) t Serial port for control by PC or to integrate with an automation system. Commands like “AT” t Plug & Play expansion modules, no programming necessary t EOL supervised siren output and zone inputs t Zone type can be selectable as button or detector t Zone test feature TFX-108 t 6-25V adjustable 1A power output with automatic fuse t 1 pc. NC/NO customizable fire relay (Button alarm, detector alarm etc.) t 1pc.NC/NO customizable error relay (Mains failure zone, battery trouble etc) t Bypass feature, “BYPASS” led on the front panel, bypassed zones can be seen on LCD t Key system to determine authorization level, warning messages on screen when key needed t Easy to understand front panel, menu system for easyprogramming t Support for multi language t Switched power supply t Metal box t Ready places in box for expand modules t Compact, small dimensions t Used with 2 pcs of 12V 7Ah battery t Designed to comply with European and US standarts 8 Zones Expansion Board for TFP-900 Series t 8 zones with end of line resistor t Having charged from panel, no need extra power supply 34 www.teknim.com | [email protected] Fire Alarm Panels Conventional Fire Alarm Panel t 24V, 8 zones t 1 pc NC/NO fire relay t Separate fire and trouble t 1 pc NC/NO trouble relay LEDs for each zone t EOL supervisory for zone inputs and siren output t Zone test feature t 24V 0,5A AUX power output with automatic fuse protected t 0,5A automatic fuse protected siren output t Bypass feature t Key protected front panel buttons against unwanted interference t Easy to understand front panel t Metal box t Designed to comply with European and US standarts Intruder Alarm Sytems TFP-808 Fire relay Trouble relay Dimensions (WxHxD) Weight x2 8 6,8kΩ 230V, 35VA 24VDC, 0,5A with automatic fuse 24VDC, 0,5A with automatic fuse, 6,8kΩ EOL supervised 30V 1A NC/NO dry contact 30V 1A NC/NO dry contact 370x310x100mm 4kg BYPASS www.teknim.com | [email protected] Conventional Fire Alarm Systems Technical Specifications Zone End of line resistor Mains input Aux output Siren output 35 Fire Alarm Panels Conventional Fire Alarm Systems Intruder Alarm Sytems TFP-802 / 804 Conventional Fire Alarm Panels t Just 1 pc 12V 7Ah battery required t 24V, 2 zones (TFP-802) or 4 zones (TFP-804) t Each zone has separate fire and trouble LEDs t Supervised siren outputs and zone inputs by end of line resistor t Zone test feature t 12V / 24V selectable, automatic fuse protected auxilary power output t NC/NO fire relay x1 t Requested zones can be bypassed t Key lock system against unwanted intervention t Easy to understand front panel t Metal box t Bypass each zones t Intelligent battery charging system to prolong battery life t Compact design t Microprocessor t SMD material technology t Designed to comply with European and US standarts BYPASS Technical Specifications Zone Battery Number of detectors End of line resistor Power supply Power output Siren output Fire relay Trouble relay Humidity Temperature Dimensions (WxHxD) Weight 2 (TFP-802) / 4 (TFP-804) 1 pc 12V 7Ah, sealed type, lead acid Up to 30 pcs for each zone 6,8kΩ 230V, 25VA with internal transformer 250mA internal fuse protection 12/24VDC selectable, automatic fuse, TFP-802: 500mA 12V or 300mA 24V TFP-804: 500mA 12V or 500mA 24V 24VDC, 6,8kΩ end of line resistor 30V 1A NC/NO dry contact 30V 1A NC/NO dry contact 95% RH (Max) -10°C ~ 55°C (14°F ~ 131°F) 210x300x80mm 2,5kg (Without packing and battery) TFP-800 Series MODEL Zone Battery End of line resistor Power supply Power output Siren output Fire relay Trouble relay Key lock Box Humidity Temperature Dimensions (WxHxD) Weight 36 t NC/NO trouble relay Conventional Fire Alarm Panels Comparison Table TFP-802 2 1 pc 12V 7Ah, sealed type, lead acid 6,8kΩ 230V, 25VA 12/24VDC selectable, automatic fuse 12/24VDC selectable, automatic fuse 500mA 12V or 300mA 24V 30V 1A NC/NO dry contact 30V 1A NC/NO dry contact YES Metal 95% RH (Max) -10°C ~ 55°C (14°F ~ 131°F) 210x300x80mm 2,5kg (Without packing and battery) TFP-804 4 1 pc 12V 7Ah, sealed type, lead acid 6,8kΩ 230V, 25VA 12/24VDC selectable, automatic fuse 12/24VDC selectable, automatic fuse 500mA 12V or 500mA 24V 30V 1A NC/NO dry contact 30V 1A NC/NO dry contact YES Metal 95% RH (Max) -10°C ~ 55°C (14°F ~ 131°F) 210x300x80mm 2,5kg (Without packing and battery) www.teknim.com | [email protected] TFP-808 8 2 pc 12V 7Ah, sealed type, lead acid 6,8kΩ 230V, 35VA 12/24VDC selectable, automatic fuse 12/24VDC selectable, automatic fuse 30V 1A NC/NO dry contact 30V 1A NC/NO dry contact YES Metal 95% RH (Max) -10°C ~ 55°C (14°F ~ 131°F) 370x310x100mm 4kg (Without packing and battery) Fire Alarm Detectors TFD-1250 Optical Smoke + Heat Intruder Alarm Sytems Multisensor Detector TFD-1250, is an Optical Smoke + Heat Detectors were designed with precise CPU control and thermister detection. It is state of the art combination of 'Optical Smoke' and 'Fixed Temperature' ensures the best quality of heat detection in all environment. Detectors were engineered to the best quality and durability. They work perfectly with all conventional fire control panels. t 2 wire model t Advanced detection and discrimination algorithms t SMD circuit board design-satisfactory quality and reliability guarenteed t Plastic, white housing high temperature endurable and fireproof polymeric material t Alarm indicator LED can be seen from all points of view (360°, continuosly emitting red light t Easy installation and maintenance t Sleek low-profile housing design t High quality and reliability guarenteed t Strong body t Designed to comply with European and US standarts t Base Included TFD-1230 Technical Specifications Wire Operation voltage Alarm current Standby current Operation temperature Alarm temperature Relative humidity Installation method Dimensions Casing material Weight (base included) 2 wire 20-28VDC 100mA max. 100µA max. -10°C to 50°C 57°C 0% to 95%, no condensation or icing Ceiling mounted ø110, H:50mm Plastic, white 0,110kg Conventional Fire Alarm Systems t Durable sensor head, no need for replacement Optical Smoke Detector TFD-1230, is an Optical Smoke Detector provides reliable early warning of intense fires with fast response by detection smoke particles. It has the function of dustproof, mothproof, and anti-electromagnetic interference. It performs well in detecting visible smoke caused by hidden or bright fire. It is suitable for detecting smoke in houses, stores, hotels and warehouses, etc. Detectors were engineered to the best quality and durability. They work perfectly with all conventional fire control panels. t 2 wire model t Detection of intense fires with fast response under rapid temperature-rise situation t SMD circuit board design-satisfactory quality and reliability guaranteed t Mechanical moving parts provide stability, durability and reliability t Self-restoring bimetal elements allow continual use t Plastic, white housing high temperature endurable and fireproof polymeric material t Alarm indicator LED, continuosly emitting red light t Easy installation and maintenance t Designed to comply with European and US standarts t Base Included Technical Specifications Wire Operation voltage Alarm current Standby current Operation temperature Relative humidity Installation method Dimensions Casing material Weight (base included) www.teknim.com | [email protected] 2 wire 20-28VDC 100mA max. 100µA max. -10°C to 50°C 0% to 95%, no condensation or icing Ceiling mounted ø110, H:50mm Plastic, white 0,110kg 37 Fire Alarm Detectors TFD-1220 Fixed Temperature + Conventional Fire Alarm Systems Intruder Alarm Sytems Temperature Increase Detector TFD-1220, is a Fixed Temperature & Temperature Increase Detector provides reliable early warning of intense fires with fast response under rapid temperature-rise situation. Detectors were engineered to the best quality and durability. They work perfectly with all conventional fire control panels. t 2 wire model t Detection of intense fires with fast response under rapid temperature-rise situation t SMD circuit board design-satisfactory quality and reliability guarenteed t Mechanical moving parts provide stability, durability and reliability t Self-restoring bimetal elements allow continual use t Plastic, white housing high temperature endurable and fireproof polymeric material t Alarm indicator LED, continuosly emitting red light t Easy installation and maintenance t Sleek low-profile housing design t High quality and reliability guarenteed t Strong body t Designed to comply with European and US standarts t Base Included TFD-1210 Technical Specifications Wire Operation voltage Alarm current Standby current Operation temperature Alarm temperature Relative humidity Installation method Dimensions Casing material Weight (base included) 2 wire 20-28VDC 50mA max. 50µA max. -10°C to 50°C 57°C 0% to 95%, no condensation or icing Ceiling mounted ø110, H:50mm Plastic, white 0,110kg Fixed Temperature Detector TFD-1210, is a Fixed Temperature Detector provides reliable early warning of a fire condition upon ambient temperature reaching a fixed temperature threshold. Detectors were engineered to the best quality and durability. They work perfectly with all conventional fire control panels. t 2 wire model t Detection of intense fires with fast response under rapid temperature-rise situation t SMD circuit board design-satisfactory quality and reliability guaranteed t Mechanical moving parts provide stability, durability and reliability t Self-restoring bimetal elements allow continual use t Plastic, white housing high temperature endurable and fireproof polymeric material t Alarm indicator LED, continuosly emitting red light t Easy installation and maintenance t Sleek low-profile housing design t High quality and reliability guarenteed t Strong body t Designed to comply with European and US standarts t Base Included 38 Technical Specifications Wire Operation voltage Alarm current Standby current Operation temperature Alarm temperature Relative humidity Installation method Dimensions Casing material Weight (base included) www.teknim.com | [email protected] 2 wire 20-28VDC 50mA max. 50µA max. -10°C to 50°C 57°C 0% to 95%, no condensation or icing Ceiling mounted ø110, H:50mm Plastic, white 0,110kg Indoor Fire Sirens & Strobes TFS-202 is used to produce signalization up on detected fire condition. It is highly preferred for internal usage because of its aesthetics design and easy to use. The sounder provides sounds level 85dB. Technical Specifications Supply voltage Current consumption in duty mode Current consumption in activated sounder Sound level at 1m distance Operational temperature range Relative humidity resistance Dimensions (WxHxD) Weight (base included) Cross section of the connecting wire Degree of protection TFS-201 20-28VDC 500µA 22mA@24V 100dB -10°C to 55°C (93±3) at 40°C 130x110x40mm 0,267kg (0,8-2,5)mm2 IP30 Indoor Fire Siren TFS-201 is designed to produce signalization up on detected fire condition. It is highly preferred for internal usage because of its aesthetics design and easy to use. The sounder provides sounds level 85dB. Intruder Alarm Sytems Indoor Fire Siren (with strobe) Conventional Fire Alarm Systems TFS-202 Technical Specifications Supply voltage Current consumption in duty mode Current consumption in activated sounder Sound level at 1m distance Operational temperature range Relative humidity resistance Dimensions (WxHxD) Weight (base included) Cross section of the connecting wire Degree of protection TFS-203 20-28VDC 500µA 18mA@24V 100dB -10°C to 55°C (93±3) at 40°C 130x110x40mm 0,267kg (0,8-2,5)mm2 IP30 Indoor Fire Strobe TFS-203 is used to produce silent but visual signalization up on detected fire condition. It is highly preferred for internal usage because of its aesthetics design and easy to use. www.teknim.com | [email protected] 39 Outdoor Fire Sirens & Gas Detectors VAS-740 F Outdoor Fire Siren Intruder Alarm Sytems t 2 wires t 6 super bright LEDs t 115dB sound level (@24V DC, from 1m distance) t Frequency: 500-1400Hz t 100mA@24V operating current t 20-28V DC t Operating temperature: -20°C - 70°C arası t Dimensions: 215x300x60mm Conventional Fire Alarm Systems t UL 94 fireproof red ABS body TGD-904F Carbonmonoxide Detector for Conventional Fire Alarm Panels t Microprocessor design t Highly stable detection feature t Automatic reset after alarm t Internal 70dB siren t Relay output t Relay output t 8-24V DC t Recommended for ceiling mounting t LED can be seen from all points of view (360)° TGD-903F Natural Gas Detector for Conventional Fire Alarm Panels t Microprocessor design t Highly stable detection feature t Automatic reset after alarm t Internal 70dB siren t Relay output t Relay output t 8-24V DC t Recommended for ceiling mounting t LED can be seen from all points of view (360)° 40 www.teknim.com | [email protected] Security is not the one and only thing we care about... All Teknim products are produced with eco-friendly production techniques. All TEKNİM products comply with the RoHs directive 2002/95/EC, restricts the use of toxic substances (such as lead, mercury, cadmium, hexavalent chrome, polybrominated biphenyls, polybrominated diphenyl ethers) widely used in electronics. (For more information www.rohs.eu ) We care about the health of yours and your beloved ones. We care about the earth that we live on. Dudullu Organize Sanayi Bolgesi 1. Cadde Ismet Tarman Is Merkezi Bina No:1 Kat:2 No:24 PK:34776 Umraniye/ ISTANBUL Telephone: +902164990680(pbx) Fax: +902164990679 [email protected] www.teknim.com