Preview only show first 10 pages with watermark. For full document please download

Seite 115 Sdr18 0,5w

   EMBED


Share

Transcript

DC/DC Converter AC/DC Inverters Delay-Lines Pulsetransformers Burst & Surge Filters Harmonic Filters Switching Power Supplies F LO E T H ELECTRONIC Am Malfinger Steig 13 86920 Denklingen/Obb. Germany Tel.: 08243-9693-0 Fax: 08243-9693-33 www.floeth-electronic.com Stand: 14/05 Regulated Single output SMD Case: SO18 package COMMERCIAL DC/DC Converters 0,5 Watt Series: SDR18 Electrical specifications: +/- 5% capacitor +/- 5% max. 1.0% max. 1,0 % max. 50mVp-p Input voltage range: Input filter: Output voltage accuracy: Line regulation: Load regulation: Ripple/Noise @20MHz BW: min. 50% min. 1000V DC min. 2000V DC 1.0 second continuous -40°C to +70°C -55°C to +125°C Efficiency at full load: Isolation voltage: Optional Part-No.: /H Short circuit protection: Optional Part-No.: /S Operating temp. range: Storage temp. range: Note: Measured conditions Ta=25°C, Vin = nominal, full load. CAUTION: NO INPUT POLARITY CHANGE ALLOWED! Model Number single Input Voltage DC Output Voltage DC Output Current mA SDR18-0505 SDR18-0512 SDR18-0515 5V 5V 12V 15V 100mA 42mA 33mA SDR18-0905 SDR18-0912 SDR18-0915 9V 5V 12V 15V 100mA 42mA 33mA SDR18-1205 SDR18-1212 SDR18-1215 12V 5V 12V 15V 100mA 42mA 33mA SDR18-1505 SDR18-1512 SDR18-1515 15V 5V 12V 15V 100mA 42mA 33mA SDR18-2405 SDR18-2412 SDR18-2415 24V 5V 12V 15V 100mA 42mA 33mA Any other input & output voltages available Mechanical Specifications: 15,24 Footprint: 8,10 PIN CONNECTION: 7,62 NC +V 18 12 DC/DC 7,10 7,30 2,54x4 9,00 11,10 1 1,80 2,54 1,20 100mA SDR18-0505 Floeth 12,00 GND 3 7 9 VCC -V -V ALL DIMENSIONS IN MM Tolerance +/-0,25mm All pins on a 2,54mm pitch. Dot marks Pin 1 We can offer EMC - Filter according to EN55011/22 Class B. Specification may be changed without notice please contact office for verification 115 DC/DC Converter AC/DC Inverters Delay-Lines Pulsetransformers Burst & Surge Filters Harmonic Filters Switching Power Supplies F LO E T H ELECTRONIC Am Malfinger Steig 13 86920 Denklingen/Obb. Germany Tel.: 08243-9693-0 Fax: 08243-9693-33 www.floeth-electronic.com Stand: 28/08 Regulated Single output SMD Case: SO18 package COMMERCIAL DC/DC Converters 1 Watt Series: SDR18 Electrical specifications: Input voltage range: Input filter: Output voltage accuracy: Line regulation: Load regulation: Ripple/Noise @20MHz BW: +/- 5% capacitor +/- 5% max. 1.0% max. 1,0 % max. 50mVp-p Efficiency at full load: Isolation voltage: Optional Part-No.: /H Short circuit protection: Optional Part-No.: /S Operating temp. range: Storage temp. range: min. 50% min. 1000V DC min. 2000V DC 1,0 second continuous (Only 3V - 5V output voltage) -40°C to +70°C -55°C to +125°C Note: Measured conditions Ta=25°C, Vin = nominal, full load. CAUTION: NO INPUT POLARITY CHANGE ALLOWED! Part-No. SDR18-xxyy Input Voltage VDC Output Voltage DC Output Current mA 3,3, 5, 9, 12, 15, 24, 30 3V - 15V Depending on Output Voltage With Short Circuit Protection (Part-No.: /S) SDR18-xx03/S 3,3, 5, 9, 12, 15, 24, 30 3V 200mA SDR18-xx03,3/S 3,3, 5, 9, 12, 15, 24, 30 3,3V 200mA SDR18-xx04,85/S 3,3, 5, 9, 12, 15, 24, 30 4,85V 200mA SDR18-xx05/S 3,3, 5, 9, 12, 15, 24, 30 5V 200mA Any other output voltages available Mechanical Specifications: Footprint: PIN CONNECTION: 15,24 9,30 7,62 NC +V 18 12 DC/DC 8,70 0,20 2,54x4 10,00 11,80 1 1,80 2,54 1,20 100mA SDR18-0505 Floeth 12,70 GND 3 7 9 VCC -V -V ALL DIMENSIONS IN MM Tolerance +/-0,25mm All pins on a 2,54mm pitch. Dot marks Pin 1 We can offer EMC - Filter according to EN55011/22 Class B. Specification may be changed without notice please contact office for verification 116