Transcript
DC/DC Converter AC/DC Inverters Delay-Lines Pulsetransformers Burst & Surge Filters Harmonic Filters Switching Power Supplies
F LO E T H ELECTRONIC
Am Malfinger Steig 13 86920 Denklingen/Obb. Germany Tel.: 08243-9693-0 Fax: 08243-9693-33 www.floeth-electronic.com
Stand: 49/15
MEDICAL - INDUSTRIAL DC/DC Converters
unregulated
6 Watt Series: MED-LHVI
Applications: - IGBT auxiliary supply - medical application
EN/UL/CSA 60601-1 & 2 REINFORCED INSULATION Electrical specifications: unregulated continuous @ 24Vin: short-time -40°C up to +95°C -40°C to +71°C
Output voltage accuracy: Short circuit protection: Operating temperature: Ambient temperature: Optional: Part-No.: /8
Efficiency: primary / secondary Insulation test voltage: Insulation: primary / secondary Capacitance Prim/Sec:
-55°C to +85°C ambient temperature
up to 85% 4000V AC rms 1 min. type test du/dt...>100kV/µs 1500V AC rms partial discharge free < 10pC typ. <15pF
CAUTION: NO INPUT POLARITY CHANGE ALLOWED!
Input Voltage DC 4,75V - 5,5V 10,8V - 13,2V 13,5V - 16,5V 21,6V - 26,4V
Part-No.
MED-LHVI-05yy MED-LHVI-12yy MED-LHVI-15yy MED-LHVI-24yy
Output Voltage DC 3,3 V 5V 12 V 15 V 24 V
Output current mA 1800mA 1100mA 500mA 400mA 250mA
Any other IN & OUTPUT voltage available !! 3,57 (0,14) - OUT + OUT
- OUT + OUT
0,50 DIA
20 19
12 11
6 7 8 9
+ IN + IN - IN - IN
30,00 (1,18)
BOTTOM VIEW
22,86 (0,90)
7,62 (0,30) 6,10 (0,24)
40,00 (1,57)
2,50 (0,01)
45,00 (1,77)
4,60 (0,18)
18,00 (0,71)
ALL DIMENSIONS IN MM (INCHES) MILLIMETERS +/- 0,5mm (INCHES +/- 0,02") All pins on a 2,54mm pitch.
additional 220µF input & output capacitors recommended ripple & noise depend on load & external capacitors
We can offer EMC - Filter according to EN55011/22 Class B.
Specification may be changed without notice please contact office for verification
85
DC/DC Converter AC/DC Inverters Delay-Lines Pulsetransformers Burst & Surge Filters Harmonic Filters Switching Power Supplies
F LO E T H ELECTRONIC
Am Malfinger Steig 13 86920 Denklingen/Obb. Germany Tel.: 08243-9693-0 Fax: 08243-9693-33 www.floeth-electronic.com
Stand: 49/15
unregulated Applications: - IGBT auxiliary supply - medical application
MEDICAL - INDUSTRIAL DC/DC Converters 2x3 Watt = 6 Watt Series: MED-LHVI
EN/UL/CSA 60601-1 & 2 REINFORCED INSULATION Electrical specifications: Output voltage accuracy: Short circuit protection: Operating temperature: Ambient temperature: Optional: Part-No.: /8
unregulated continuous @ 24Vin: short-time -40°C up to +95°C -40°C to +71°C
Efficiency: primary / secondary Insulation test voltage: Insulation: Capacitance Prim/Sec:
up to 83% 4000V AC rms 1 min. type test du/dt...>100kV/µs 1500V AC rms partial discharge free typ. <15pF
-55°C to +85°C ambient temperature
CAUTION: NO INPUT POLARITY CHANGE ALLOWED!
Part-No.
MED-LHVI-051515 MED-LHVI-121515 MED-LHVI-151515 MED-LHVI-241515
Input Voltage DC 4,75V - 5,5V 10,8V - 13,2V 13,5V - 16,5V 21,6V - 26,4V
Output Voltage DC 15V / 15V 15V / 15V 15V / 15V 15V / 15V
Output current mA 200mA / 200mA 200mA / 200mA 200mA / 200mA 200mA / 200mA
any other IN & OUTPUT voltage available also with unequal output voltages ! 3,57 (0,14) - OUT2 + OUT2
0,50 DIA
20 19 +
12 11
+
- OUT1 + OUT1
6 7 8 9
+ IN + IN - IN - IN
30,00 (1,18)
BOTTOM VIEW
22,86 (0,90)
7,62 (0,30) 6,10 (0,24)
40,00 (1,57)
2,50 (0,01)
45,00 (1,77)
4,60 (0,18)
18,00 (0,71)
ALL DIMENSIONS IN MM (INCHES) MILLIMETERS +/- 0,5mm (INCHES +/- 0,02") All pins on a 2,54mm pitch.
additional 220µF input & output capacitors recommended ripple & noise depend on load & external capacitors
We can offer EMC - Filter according to EN55011/22 Class B.
Specification may be changed without notice please contact office for verification
86