Preview only show first 10 pages with watermark. For full document please download

Semiconductor/capex

   EMBED


Share

Transcript

Semiconductor Equipment Wire and Cable Portfolio Helping Make Fabs More Productive F rom wafer handling to inspection, Alpha Wire can help you make semiconductor equipment faster, more reliable, and easier to maintain. Whether refurbishing existing equipment or developing new equipment from design through production, Alpha Wire’s extensive line of wire, cable, and accessories provide unrivaled performance and durability in the harshest environments. We also offer an extensive line-up of low outgassing products. Durable Performance Alpha’s products provide superior electrical and mechanical performance, can reduce particulation, and improve system performance and yield. Find the Cable For Your Need Consult with Alpha Wire’s engineering team for assistance in developing the ideal wire and cable solution for your equipment needs. The Service You Deserve . . . Non-shedding, low outgassing, and chemically inert versions are specially designed for cleanroom use. The Performance You Need . . . • Small custom prototyping • R  esistance to temperature extremes and harsh chemicals • E  xtensive custom cable design and manufacturing capabilities • L  ow outgassing to eliminate contamination The Reliability You Demand . . . • S  hielding options for excellent EMI resistance • Low noise for signal integrity Our complementary FIT® heatshrink tubing can be used to seal, protect, and strain-relieve connector terminations and other needs. 2 • S  maller, lighter cabling to save space and weight • ISO 9001 compliant wire and cable to satisfy recyclability requirements • Broad inventory in stock • Same-day shipping • S  mall put-ups and low minimum orders available • Extensive distributor network • Long flex life for motion control • High pull strength for easy use • U  ltra-fine wire constructions for enhanced flexibility Cables Designed for Reliability EcoCable® and EcoCable Mini Cable Low outgassing in a smaller, lighter PVC alternative EcoFlex® Control Cable Low outgassing in a lightweight, small-diameter cable for flex applications Xtra-Guard® 1 PVC Cable High mix of off-the-shelf constructions Applications Front-End Processes Xtra-Guard 5 FEP Cable Cleanroom ready low outgassing with maximum temperature and chemical performance • Deposition equipment EcoWire® and EcoWire® Plus Low outgassing in a smaller, lighter hook-up wire alternative Hook-Up Wire A full range of materials, and wire gauges to connect nearly everything to anything, including PTFE. FIT® Heat-Shrink Tubing The perfect FIT for fabs with low outgassing and chemical and solvent resistance • Etching equipment • Wafer-handling equipment • C  leanroom robotics and motion control Back-End Processes • Wafer dicing equipment • C  hip testing and packaging equipment • Package reeling equipment • Transfer equipment Fab Support Equipment • Gas delivery • Environmental systems Shielding Options to Maximize Signal Integrity Alpha Wire offers cables in four shielding options to handle virtually any electrical environment. Unshielded Foil Foil Shield: Good Braid Braid Shield: Better Braid Supra-Shield: Best Trilaminate Foil Unshielded: the smallest cable diameter for use in low-noise environments. Foil shielded: an aluminum/ polyester shield for moderate EMI needs. Braid shielded: a braided copper shield, with 55% to 85% coverage, provides good protection against higher frequency EMI. Supra-Shield® (premium foil + braid) shielded: our exclusive Supra-Shield cables combine a triple-layer aluminum/ polyester/aluminum foil with a tinned copper braid shield having tight 70% coverage for exceptional EMI performance. 3 The Right Cable . . . Just the Way You Want It Turn to Alpha Wire to get the precise Coast™ custom cable needed for your application. We can meet your needs for low outgassing, wide temperature ranges, and resistance to harsh chemicals—all with fast turns on prototypes and production. More Choice in Cable Configurations Custom Engineered to Your Specifications and Designs • Multiconductor cables • Multipair cables • Microminiature cables • Coaxial cables • Microcoaxial cables • Hybrid cables • Composite cables • Power cables • Lead wires • Flat, ribbon, zip cables • Flat, round braids • Retractable coil cords Conductor Materials Conductors: 50 AWG to 4/0 AWG Copper • Bare copper • Tinned copper • Silver-plated copper • Nickel-plated copper • Copper alloys 4 Specialty • Magnet wire • Tinsel wire • Thermocouple wire Fibers and Yarns • Carbon fiber (.5K – 12K) • Metalized carbon fiber • Aramid fiber • Stainless steel yarn Precious Metals and Alloys • Silver, platinum, gold • Other exotic materials Insulating and Jacketing Compounds Thermoplastics • PVC, SR-PVC • PP • PE • PUR • Nylon • TPE • TPR • TPA • mPPE Thermosets • XLPE Fluoropolymers • PTFE • FEP • PFA • ETFE • PVDF Silicones — Thermosets • Silicone • Flame-retardant silicone • High-voltage silicone Rubbers • Neoprene • Thermoplastic vulcanite • Melt-processible rubber Shielding Application: Overall and individual conductors/pairs Types: Foil, braid, spiral, Supra-Shield® foil + braid Flexing Cable with Integrated Lumens Flex types: Rolling, bending, torsional, continuous Flex cycles: Up to 20 million Ratings Temperature: -80° to +450°C Electrical: 30, 150, 300, 600, 1000 V . . . up to 75 kV Approvals UL, CSA, CE, IEC, ISO USP Class VI, ISO 10933 RoHS, REACH Mechanical/Environmental • • • • • • Abrasion resistance Oil resistance Chemical/solvent resistance Sunlight resistance Sterilizable Low outgassing Packaging Reeled in small or large put ups, cut to length, custom printing, custom jacket colors, 100’ minimum order Other Can design custom cables with lumens Manufactured Products Value-Added Capabilities • C  able assembly with Tier 2 partners • Coil cords • Custom packaging • Cut-to-length • Dying • Etching – Non-chemical – PTFE materials – Connector end for assembly • • • • • •  arking M Spooling (UL, CSA) Striping Stripping Tinning Twisting Intellectual Property (IP) Protection The custom specifications provide IP protection, as each part number and specification are unique to each customer requirement. The custom specification requires customer approval with formal written consent as part of the PO acknowledgment process, and prevents any design changes or material substitutions without a new spec revision level and approval. Get started today by visiting our website to request a quote on your custom cable. www.alphawire.com/customquote Contact Alpha about other custom cable options. 5 EcoCable® 600 V Control Cable Conductors: Stranded tinned copper A fully recyclable 600 V control cable that’s up to 47% smaller and 65% lighter than PVC. More than 130 standard EcoCable constructions are available to meet your performance needs. Insulation: mPPE Jacket: mPPE, slate Shielding: Unshielded, foil shield, Supra-Shield foil + braid • U  p to 87% lower outgassing than standard 600 V PVC cable • Up to 47% smaller and 65% lighter than PVC • Exceptional EMI protection with Supra-Shield® • Fully recyclable • 28 – 14 AWG • Contains no PVC, halogens, heavy metals, or phthalates Voltage: 600 V Bend Radius: 6x Temperature Range: -50°C to +105°C Availability: 100’, 1000’ (30.5 m, 305 m) Bulk, cut to length Approvals • • • • • UL AWM 21915 (600 V, 105°C) UL VW-1 CE CSA AWM I/II A/B FT2 Suitable for use in NFPA 79 applications • REACH • RoHS 22 AWG (0.35 mm2) Cable Unshielded 28 AWG (0.89 mm ) 26 AWG (0.14 mm2) Stranding: 7/36 (0.127 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Stranding: 7/34 (0.16 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) 2 6 Part Number Conductors 77052 77053 77054 77055 2 3 4 6 Nominal Diameter Inch mm 0.138 3.51 0.144 3.66 0.153 3.89 0.174 4.42 Part Number Conductors 77047 77048 77049 77050 77051 2 3 4 6 8 Nominal Diameter Inch mm 0.146 3.71 0.152 3.86 0.162 4.11 0.186 4.72 0.198 5.03 24 AWG (0.28 mm2) 22 AWG (0.35 mm2) Stranding: 7/32 (7 x 0.20 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Part Number Conductors 77001 77002 77003 77004 77005 77006 2 4 5 7 9 19 Nominal Diameter Inch mm 0.156 3.96 0.175 4.44 0.188 4.78 0.201 5.11 0.229 5.82 0.288 7.32 Part Number Conductors 77007 77008 77009 77010 77011 77012 2 4 5 7 9 19 Nominal Diameter Inch mm 0.168 4.27 0.189 4.80 0.204 5.18 0.219 5.56 0.251 6.38 0.318 8.08 EcoCable® 600 V Control Cable Unshielded (continued) 20 AWG (0.56 mm2) 18 AWG (0.81 mm2) Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Stranding: 16/30 (16 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Part Number Conductors 77013 77014 77015 77016 77017 77018 77019 3 4 9 12 15 19 25 Nominal Diameter Inch mm 0.193 4.90 0.209 5.31 0.280 7.11 0.309 7.85 0.336 8.53 0.358 9.09 0.416 10.57 Part Number Conductors 77020 77021 77022 77023 77024 77025 77026 77027 77028 77029 2 3 4 5 7 9 12 15 19 25 Nominal Diameter Inch mm 0.202 5.13 0.213 5.41 0.230 5.84 0.250 6.35 0.271 6.88 0.313 7.95 0.346 8.79 0.377 9.58 0.404 10.26 0.470 11.94 16 AWG (1.32 mm2) 14 AWG (2.08 mm2) Stranding: 19/0.0117 (19 x 0.297 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Stranding: 41/30 (41 x 0.25 mm) Insulation thickness: 0.011 (0.28 mm) Jacket thickness: 0.032 (0.81 mm) Part Number Conductors 77030 77031 77032 77033 77034 77035 77036 77037 4 5 7 9 12 15 19 25 Nominal Diameter Inch mm 0.259 6.58 0.283 7.19 0.307 7.80 0.357 9.07 0.396 10.06 0.433 11.00 0.464 11.79 0.542 13.77 Part Number Conductors 77038 77039 77040 77041 77042 77043 77044 77045 77046 2 3 4 5 7 9 12 15 25 Nominal Diameter Inch mm 0.260 6.60 0.275 6.98 0.301 7.65 0.329 8.36 0.358 9.09 0.419 10.64 0.467 11.86 0.511 12.98 0.644 16.36 Foil Shield 28 AWG (0.89 mm ) 26 AWG (0.14 mm2) Stranding: 7/36 (0.13 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Stranding: 7/34 (0.16 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) 2 Part Number Conductors 77152 77153 77154 77155 2 3 4 6 Nominal Diameter Inch mm 0.142 3.61 0.148 3.76 0.157 3.99 0.178 4.52 Part Number Conductors 77147 77148 77149 77150 77151 2 3 4 6 8 Nominal Diameter Inch mm 0.150 3.81 0.156 3.96 0.166 4.22 0.190 4.83 0.202 5.13 7 EcoCable® 600 V Control Cable Foil Shield (continued) 8 24 AWG (0.28 mm2) 22 AWG (0.35 mm2) Stranding: 7/32 (7 x 0.20 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Part Number Conductors 77102 77103 77104 77105 77106 77107 77101 2 3 4 5 7 9 12 Nominal Diameter Inch mm 0.160 4.06 0.167 4.24 0.179 4.55 0.192 4.88 0.205 5.21 0.233 5.92 0.255 6.48 Part Number Conductors 77109 77110 77111 77112 77113 77114 77108 2 3 4 5 7 9 12 Nominal Diameter Inch mm 0.172 4.37 0.180 4.57 0.193 4.90 0.208 5.28 0.223 5.66 0.255 6.48 0.280 7.11 20 AWG (0.56 mm2) 18 AWG (0.81 mm2) Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Stranding: 16/30 (16 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Part Number Conductors 77116 77117 77118 77119 77120 77115 3 4 5 7 9 12 Nominal Diameter Inch mm 0.197 5.00 0.213 5.41 0.230 5.84 0.247 6.27 0.284 7.21 0.313 7.95 Part Number Conductors 77124 77126 77127 77128 77129 77130 77121 77122 77123 77125 2 3 4 5 7 9 12 15 19 25 Nominal Diameter Inch mm 0.206 5.23 0.217 5.51 0.234 5.94 0.254 6.45 0.275 6.98 0.317 8.05 0.350 8.89 0.381 9.68 0.408 10.36 0.474 12.04 16 AWG (1.32 mm2) 14 AWG (2.08 mm2) Stranding: 19/0.0117 (19 x 0.297 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Stranding: 41/30 (41 x 0.25 mm) Insulation thickness: 0.011 (0.28 mm) Jacket thickness: 0.032 (0.81 mm) Part Number Conductors 77133 77134 77135 77136 77137 77138 77131 77132 2 3 4 5 7 9 12 15 Nominal Diameter Inch mm 0.230 5.84 0.242 6.15 0.263 6.68 0.287 7.29 0.311 7.90 0.361 9.17 0.400 10.16 0.437 11.10 Part Number Conductors 77141 77142 77143 77144 77145 77146 77139 77140 2 3 4 5 7 9 12 15 Nominal Diameter Inch mm 0.264 6.71 0.279 7.09 0.305 7.75 0.333 8.46 0.362 9.19 0.423 10.74 0.471 11.96 0.515 13.08 EcoCable® 600 V Control Cable Supra-Shield® Foil + Braid 28 AWG (0.89 mm2) 26 AWG (0.14 mm2) Stranding: 7/36 (0.13 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Stranding: 7/34 (0.16 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Part Number Conductors 77252 77253 77254 77255 2 3 4 6 Nominal Diameter Inch mm 0.166 4.22 0.172 4.37 0.181 4.60 0.202 5.13 Part Number Conductors 77247 77248 77249 77250 77251 2 3 4 6 8 Nominal Diameter Inch mm 0.174 4.42 0.180 4.57 0.190 4.83 0.214 5.44 0.226 5.74 24 AWG (0.28 mm2) 22 AWG (0.35 mm2) Stranding: 7/32 (7 x 0.20 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Part Number Conductors 77201 77202 77203 4 7 12 Nominal Diameter Inch mm 0.203 5.16 0.229 5.82 0.279 7.09 Part Number Conductors 77204 77205 77206 4 7 12 Nominal Diameter Inch mm 0.217 5.51 0.247 6.27 0.304 7.72 20 AWG (0.56 mm2) 18 AWG (0.81 mm2) Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Stranding: 16/30 (16 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Part Number Conductors 77207 77208 77209 77210 77211 77212 4 5 7 9 12 19 Nominal Diameter Inch mm 0.237 6.02 0.254 6.45 0.271 6.88 0.308 7.82 0.337 8.56 0.386 9.80 Part Number Conductors 77213 77214 77215 77216 77217 77218 77219 77220 77221 2 3 4 5 7 9 12 15 19 Nominal Diameter Inch mm 0.230 5.84 0.241 6.12 0.258 6.55 0.278 7.06 0.299 7.59 0.341 8.66 0.374 9.50 0.405 10.29 0.432 10.97 16 AWG (1.32 mm2) 14 AWG (2.08 mm2) Stranding: 19/0.0117 (19 x 0.297 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.032 (0.81 mm) Stranding: 41/30 (41 x 0.25 mm) Insulation thickness: 0.011 (0.28 mm) Jacket thickness: 0.032 (0.81 mm) Part Number Conductors 77222 77223 77224 77225 77226 77227 77228 77229 77230 2 3 4 5 7 9 12 15 19 Nominal Diameter Inch mm 0.254 6.45 0.266 6.76 0.287 7.29 0.311 7.90 0.335 8.51 0.385 9.78 0.424 10.77 0.461 11.71 0.492 12.50 Part Number Conductors 77231 77232 77233 77234 77235 77236 77237 77238 2 3 4 7 9 12 15 25 Nominal Diameter Inch mm 0.288 7.32 0.303 7.70 0.329 8.36 0.386 9.80 0.447 11.35 0.495 12.57 0.539 13.69 0.678 17.22 9 EcoCable® Mini 300 V Cable This 300 V cable is up to 32% smaller and 44% lighter than PVC cable. More than 200 standard configurations make it easy for you to design smaller, lighter devices. • U  p to 32% smaller and 44% lighter than PVC • 92% lower outgassing than PVC • 28 to 20 AWG • Easier routing and installation • Variety of shielding options • 100% recyclable mPPE insulation and jacketing Conductors: Stranded tinned copper Insulation: mPPE Jacket: mPPE, slate Shielding: Unshielded, foil shield, individually foil shielded pairs + overall foil shield, Supra-Shield® Foil + Braid Voltage: 300 V Temperature Range: -40°C to +80°C Availability: 100’, 1000’ (30.5 m, 305 m) Bulk, cut to length Approvals • • • • UL AWM 21460 • CE CSA I A/B FT1 • RoHS REACH • WEEE Suitable for use in NFPA 79 applications • Meets UL VW-1 Flame Rating 28 AWG (0.382 mm2) Cable Unshielded Pairs 10 28 AWG (0.0925 mm2) 26 AWG (0.154 mm2) Stranding: 19/40 (19 x 0.079 mm) Insulation thickness: 0.007 (0.18 mm) Jacket thickness: 0.015 (0.38 mm) Stranding: 19/38 (19 x 0.102 mm) Insulation thickness: 0.007 (0.18 mm) Jacket thickness: 0.015 (0.38 mm) Part Number Pairs 78052 78053 78054 78005 78056 78058 78009 2 3 4 5 6 8 9 Nominal Diameter Inch mm 0.132 3.35 0.140 3.56 0.153 3.89 0.167 4.24 0.182 4.62 0.198 5.03 0.213 5.41 Part Number Pairs 78062 78063 78064 78015 78066 78068 78019 2 3 4 5 6 8 9 Nominal Diameter Inch mm 0.146 3.71 0.154 3.91 0.169 4.29 0.185 4.70 0.202 5.13 0.219 5.56 0.237 6.02 EcoCable® Mini 300 V Cable Unshielded Pairs (continued) 24 AWG (0.241 mm2) 22 AWG (0.382 mm2) Stranding: 19/36 (19 x 0.127 mm) Insulation thickness: 0.007 (0.18 mm) Jacket thickness: 0.015 (0.38 mm) Stranding: 19/34 (19 x 0.16 mm) Insulation thickness: 0.007 (0.18 mm) Jacket thickness: 0.015 (0.38 mm) Part Number Pairs 78072 78073 78074 78025 78076 78078 78029 2 3 4 5 6 8 9 Nominal Diameter Inch mm 0.162 4.11 0.172 4.37 0.189 4.80 0.207 5.26 0.227 5.77 0.247 6.27 0.267 6.78 Part Number Pairs 78082 78083 78084 78035 78086 78088 78039 2 3 4 5 6 8 9 Nominal Diameter Inch mm 0.185 4.70 0.197 5.00 0.217 5.51 0.239 6.07 0.261 6.63 0.285 7.24 0.309 7.85 20 AWG (0.616 mm2) Stranding: 19/32 (19 x 0.203 mm) Insulation thickness: 0.007 (0.18 mm) Jacket thickness: 0.015 (0.38 mm): Part Number Pairs 78092 78093 78094 78045 78096 78098 78049 2 3 4 5 6 8 9 Nominal Diameter Inch mm 0.211 5.36 0.225 5.72 0.248 6.30 0.274 6.96 0.301 7.65 0.328 8.33 0.356 9.04 Foil Shielded, Multiconductor 28 AWG (0.0925 mm2) 26 AWG (0.154 mm2) Stranding: 19/40 (19 x 0.079 mm) Insulation thickness: 0.007 (0.18 mm) Jacket thickness: 0.015 (0.38 mm) Stranding: 19/38 (19 x 0.102 mm) Insulation thickness: 0.007 (0.18 mm) Jacket thickness: 0.015 (0.38 mm) Part Number Conductors 78102 78103 78104 78106 78108 2 3 4 6 8 Nominal Diameter Inch mm 0.098 2.49 0.103 2.62 0.111 2.82 0.128 3.25 0.138 3.51 Part Number Conductors 78112 78113 78114 78116 78118 78120 78121 2 3 4 6 8 10 15 Nominal Diameter Inch mm 0.106 2.69 0.111 2.82 0.12 3.05 0.14 3.56 0.151 3.84 0.174 4.42 0.194 4.93 11 EcoCable® Mini 300 V Cable Foil Shielded, Multiconductor (continued) 24 AWG (0.241 mm2) 22 AWG (0.382 mm2) Stranding: 19/36 (19 x 0.127 mm) Insulation thickness: 0.007 (0.18 mm) Jacket thickness: 0.015 (0.38 mm) Stranding: 19/34 (19 x 0.16 mm) Insulation thickness: 0.007 (0.18 mm) Jacket thickness: 0.015 (0.38 mm) Part Number Conductors 78122 78123 78124 78126 78128 78130 78131 2 3 4 6 8 10 15 Nominal Diameter Inch mm 0.116 2.95 0.122 3.10 0.132 3.35 0.156 3.96 0.168 4.27 0.194 4.93 0.217 5.51 Part Number Conductors 78132 78133 78134 78136 78138 78140 78141 2 3 4 6 8 10 15 Nominal Diameter Inch mm 0.13 3.30 0.137 3.48 0.149 3.78 0.177 4.50 0.191 4.85 0.222 5.64 0.249 6.32 20 AWG (0.616 mm2) Stranding: 19/32 (19 x 0.203 mm) Insulation thickness: 0.007 (0.18 mm) Jacket thickness: 0.015 (0.38 mm) Part Number Conductors 78142 78143 78144 78146 78148 78150 78155 2 3 4 6 8 10 15 Nominal Diameter Inch mm 0.146 3.71 0.154 3.91 0.169 4.29 0.201 5.11 0.218 5.54 0.254 6.45 0.286 7.26 Foil Shielded, Pairs 28 AWG (0.0925 mm ) 26 AWG (0.154 mm2) Stranding: 19/40 (19 x 0.079 mm) Insulation thickness: 0.007 (0.18 mm) Jacket thickness: 0.015 (0.38 mm) Stranding: 19/38 (19 x 0.102 mm) Insulation thickness: 0.007 (0.18 mm) Jacket thickness: 0.015 (0.38 mm) 2 Part Number Pairs 78152 78153 78154 78105 78156 78158 78109 2 3 4 5 6 8 9 Nominal Diameter Inch mm 0.136 3.45 0.144 3.66 0.157 3.99 0.171 4.34 0.186 4.72 0.202 5.13 0.217 5.51 24 AWG (0.241 mm2) Stranding: 19/36 (19 x 0.127 mm) Insulation thickness: 0.007 (0.18 mm) Jacket thickness: 0.015 (0.38 mm) 12 Part Number Pairs 78172 78173 78174 78125 78176 78178 78129 2 3 4 5 6 8 9 Nominal Diameter Inch mm 0.166 4.22 0.176 4.47 0.193 4.90 0.211 5.36 0.231 5.87 0.251 6.38 0.271 6.88 Part Number Pairs 78162 78163 78164 78115 78166 78168 78119 2 3 4 5 6 8 9 Nominal Diameter Inch mm 0.150 3.81 0.158 4.01 0.173 4.39 0.189 4.80 0.206 5.23 0.223 5.66 0.241 6.12 EcoCable® Mini 300 V Cable Foil Shielded, Pairs (continued) 22 AWG (0.382 mm2) 20 AWG (0.616 mm2) Stranding: 19/34 (19 x 0.16 mm) Insulation thickness: 0.007 (0.18 mm) Jacket thickness: 0.015 (0.38 mm) Stranding: 19/32 (19 x 0.203 mm) Insulation thickness: 0.007 (0.18 mm) Jacket thickness: 0.015 (0.38 mm) Part Number Pairs 78182 78183 78184 78135 78186 78188 78139 2 3 4 5 6 8 9 Nominal Diameter Inch mm 0.189 4.80 0.201 5.11 0.221 5.61 0.243 6.17 0.265 6.73 0.289 7.34 0.313 7.95 Part Number Pairs 78192 78193 78194 78145 78196 78198 78149 2 3 4 5 6 8 9 Nominal Diameter Inch mm 0.215 5.46 0.229 5.82 0.252 6.40 0.278 7.06 0.305 7.75 0.332 8.43 0.360 9.14 Individually Foil Shielded Pairs + Overall Foil Shield 28 AWG (0.0925 mm2) 26 AWG (0.154 mm2) Stranding: 19/40 (19 x 0.079 mm) Insulation thickness: 0.007 (0.18 mm) Jacket thickness: 0.015 (0.38 mm) Stranding: 19/38 (19 x 0.102 mm) Insulation thickness: 0.007 (0.18 mm) Jacket thickness: 0.015 (0.38 mm) Part Number Pairs 78202 78213 78204 78205 78206 78208 78209 2 3 4 5 6 8 9 Nominal Diameter Inch mm 0.153 3.89 0.177 4.50 0.194 4.93 0.211 5.36 0.229 5.82 0.247 6.27 0.153 3.89 Part Number Pairs 78212 78223 78214 78215 78216 78218 78219 2 3 4 5 6 8 9 Nominal Diameter Inch mm 0.167 4.24 0.162 4.11 0.194 4.93 0.213 5.41 0.232 5.89 0.252 6.40 0.273 6.93 24 AWG (0.241 mm2) 22 AWG (0.382 mm2) Stranding: 19/36 (19 x 0.127 mm) Insulation thickness: 0.007 (0.18 mm) Jacket thickness: 0.015 (0.38 mm) Stranding: 19/34 (19 x 0.16 mm) Insulation thickness: 0.007 (0.18 mm) Jacket thickness: 0.015 (0.38 mm) Part Number Pairs 78222 78233 78224 78225 78226 78228 78229 2 3 4 5 6 8 9 Nominal Diameter Inch mm 0.185 4.70 0.177 4.50 0.215 5.46 0.237 6.02 0.259 6.58 0.282 7.16 0.305 7.75 Part Number Pairs 78232 78243 78234 78235 78236 78238 78239 2 3 4 5 6 8 9 Nominal Diameter Inch mm 0.209 5.31 0.196 4.98 0.245 6.22 0.270 6.86 0.296 7.52 0.322 8.18 0.349 8.86 20 AWG (0.616 mm2) Stranding: 19/32 (19 x 0.203 mm) Insulation thickness: 0.007 (0.18 mm) Jacket thickness: 0.015 (0.38 mm) Part Number Pairs 78242 78253 78244 78245 78246 78248 78249 2 3 4 5 6 8 9 Nominal Diameter Inch mm 0.237 6.02 0.222 5.64 0.279 7.09 0.308 7.82 0.338 8.59 0.369 9.37 0.400 10.16 13 EcoCable® Mini 300 V Cable Supra-Shield® Foil + Braid, Multiconductor 28 AWG (0.0925 mm2) 26 AWG (0.154 mm2) Stranding: 19/40 (19 x 0.079 mm) Insulation thickness: 0.007 (0.18 mm) Jacket thickness: 0.015 (0.38 mm) Stranding: 19/38 (19 x 0.102 mm) Insulation thickness: 0.007 (0.18 mm) Jacket thickness: 0.015 (0.38 mm) Part Number Conductors 78302 78303 78304 78306 78308 2 3 4 6 8 Nominal Diameter Inch mm 0.121 3.07 0.126 3.20 0.134 3.40 0.151 3.84 0.161 4.09 Conductors 78312 78313 78314 78316 78318 78320 78320 2 3 4 6 8 10 15 Nominal Diameter Inch mm 0.129 3.28 0.134 3.40 0.143 3.63 0.163 4.14 0.174 4.42 0.197 5.00 0.217 5.51 24 AWG (0.241 mm2) 22 AWG (0.382 mm2) Stranding: 19/36 (19 x 0.127 mm) Insulation thickness: 0.007 (0.18 mm) Jacket thickness: 0.015 (0.38 mm) Stranding: 19/34 (19 x 0.16 mm) Insulation thickness: 0.007 (0.18 mm) Jacket thickness: 0.015 (0.38 mm) Part Number Conductors 78322 78323 78324 78326 78328 78330 78331 2 3 4 6 8 10 15 Nominal Diameter Inch mm 0.139 3.53 0.145 3.68 0.155 3.94 0.179 4.55 0.191 4.85 0.217 5.51 0.240 6.10 20 AWG (0.616 mm2) Stranding: 19/32 (19 x 0.203 mm) Insulation thickness: 0.007 (0.18 mm) Jacket thickness: 0.015 (0.38 mm) 14 Part Number Part Number Conductors 78342 78343 78344 78346 78348 78350 78355 2 3 4 6 8 10 15 Nominal Diameter Inch mm 0.169 4.29 0.177 4.50 0.192 4.88 0.224 5.69 0.241 6.12 0.277 7.04 0.309 7.85 Part Number Conductors 78332 78333 78334 78336 78338 78340 78341 2 3 4 6 8 10 15 Nominal Diameter Inch mm 0.153 3.89 0.16 4.06 0.172 4.37 0.200 5.08 0.214 5.44 0.245 6.22 0.272 6.91 EcoCable® Mini 300 V Cable Supra-Shield® Foil + Braid, Pairs 28 AWG (0.0925 mm2) 26 AWG (0.154 mm2) Stranding: 19/40 (19 x 0.079 mm) Insulation thickness: 0.007 (0.18 mm) Jacket thickness: 0.015 (0.38 mm) Stranding: 19/38 (19 x 0.102 mm) Insulation thickness: 0.007 (0.18 mm) Jacket thickness: 0.015 (0.38 mm) Part Number Pairs 78352 78353 78354 78305 78356 78358 78309 2 3 4 5 6 8 9 Nominal Diameter Inch mm 0.159 4.04 0.167 4.24 0.180 4.57 0.194 4.93 0.209 5.31 0.225 5.72 0.240 6.10 Part Number Pairs 78362 78363 78364 78315 78366 78368 78319 2 3 4 5 6 8 9 Nominal Diameter Inch mm 0.173 4.39 0.181 4.60 0.196 4.98 0.212 5.38 0.229 5.82 0.246 6.25 0.264 6.71 24 AWG (0.241 mm2) 22 AWG (0.382 mm2) Stranding: 19/36 (19 x 0.127 mm) Insulation thickness: 0.007 (0.18 mm) Jacket thickness: 0.015 (0.38 mm) Stranding: 19/34 (19 x 0.16 mm) Insulation thickness: 0.007 (0.18 mm) Jacket thickness: 0.015 (0.38 mm) Part Number Pairs 78372 78373 78374 78325 78376 78378 78329 2 3 4 5 6 8 9 Nominal Diameter Inch mm 0.189 4.80 0.199 5.05 0.216 5.49 0.234 5.94 0.254 6.45 0.274 6.96 0.294 7.47 Part Number Pairs 78382 78383 78384 78335 78386 78388 78349 2 3 4 5 6 8 9 Nominal Diameter Inch mm 0.212 5.38 0.224 5.69 0.244 6.20 0.266 6.76 0.288 7.32 0.312 7.92 0.336 8.53 20 AWG (0.616 mm2) Stranding: 19/32 (19 x 0.203 mm) Insulation thickness: 0.007 (0.18 mm) Jacket thickness: 0.015 (0.38 mm) Part Number Pairs 78392 78393 78394 78335 78396 78398 78339 2 3 4 5 6 8 9 Nominal Diameter Inch mm 0.238 6.05 0.252 6.40 0.275 6.99 0.301 7.65 0.328 8.33 0.355 9.02 0.383 9.73 15 EcoFlex® 600 V Control Cable Rated for over 1 million flex life cycles, EcoFlex is a fully recyclable compact cable that’s up to 32% smaller and 55% lighter than PVC. Conductors: Stranded tinned copper • U  p to 32% smaller and 55% lighter than PVC • 91% lower outgassing than PVC • Long flex life for machines with constant flexibility • Fully recyclable • 28 – 10 AWG • Contains no PVC, phthalates, halogens, or heavy metals • Exceptional EMI performance with Supra-Shield® • Rated for over 1 million flex life cycles Shielding: Unshielded, foil shield, braid shield (85% coverage), Supra-Shield Foil + Braid Insulation: mPPE Jacket: mPPE, slate Voltage: 600 V Approvals Bend Radius: Unshielded: 5x Static, 5x Flexing Shielded: 6x Static, 8x Flexing • • • • • • Temperature Range: -40°C to +105°C Availability: 100’, 1000’ (30.5 m, 305 m) Bulk, cut to length UL AWM 21819 (600 V, 105°C) UL AWM 21492 (300 V, 80°C) CE UL VW-1 CSA AWM I/II A/B FT1 Suitable for use in NFPA79 applications • RoHS • REACH Unshielded 16 28 AWG (0.09 mm2) 26 AWG (0.14 mm2) Stranding: 7/36 (7 x 0.13 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.035 (0.89 mm) Stranding: 7/34 (7 x 0.16 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.035 (0.89 mm) Part Number Conductors 79061 79062 2 3 Nominal Diameter Inch mm 0.142 3.61 0.147 3.73 Part Number Conductors 79056 79057 79058 79059 79060 2 3 4 6 8 Nominal Diameter Inch mm 0.150 3.81 0.156 3.96 0.166 4.22 0.189 4.80 0.216 5.49 24 AWG (0.24 mm2) 22 AWG (0.38 mm2) Stranding: 19/36 (19 x 0.13 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.035 (0.89 mm) Stranding: 19/34 (19 x 0.16 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.035 (0.89 mm) Part Number Conductors 79050 79051 79052 79053 79054 79055 2 3 4 6 8 10 Nominal Diameter Inch mm 0.162 4.11 0.169 4.29 0.181 4.60 0.207 5.26 0.238 6.05 0.257 6.53 Part Number Conductors 79044 79045 79046 79047 79048 79049 2 3 4 6 8 10 Nominal Diameter Inch mm 0.176 4.47 0.184 4.67 0.198 5.03 0.228 5.79 0.264 6.71 0.286 7.26 EcoFlex® 600 V Control Cable Unshielded (continued) 20 AWG (0.51 mm2) 18 AWG (0.81 mm2) Stranding: 10/30 (10 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.035 (0.89 mm) Stranding: 16/30 (16 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.035 (0.89 mm) Part Number Conductors 79001 79002 79003 79004 79005 79006 79007 79008 2 3 4 5 7 9 12 18 Nominal Diameter Inch mm 0.184 4.67 0.193 4.90 0.207 5.26 0.224 5.69 0.240 6.10 0.296 7.52 0.303 7.70 0.349 8.86 Part Number Conductors 79010 79011 79012 79013 79014 79015 79016 79017 2 3 4 5 7 9 12 18 Nominal Diameter Inch mm 0.208 5.28 0.219 5.56 0.236 5.99 0.256 6.50 0.277 7.04 0.344 8.74 0.353 8.97 0.411 10.44 16 AWG (1.32 mm2) 14 AWG (2.08 mm2) Stranding: 26/30 (26 x 0.25 mm) Insulation thickness: 0.011 (0.28 mm) Jacket thickness: 0.035 (0.89 mm) Stranding: 41/30 (41 x 0.25 mm) Insulation thickness: 0.011 (0.28 mm) Jacket thickness: 0.035 (0.81 mm) Part Number Conductors 79019 79020 79021 79022 79023 79024 79025 79026 2 3 4 5 7 9 12 18 Nominal Diameter Inch mm 0.236 5.99 0.249 6.32 0.270 6.86 0.294 7.47 0.319 8.10 0.400 10.16 0.411 10.44 0.481 12.22 Part Number Conductors 79028 79029 79030 79031 79032 79033 79034 79035 2 3 4 5 7 9 12 18 Nominal Diameter Inch mm 0.266 6.76 0.281 7.14 0.307 7.80 0.335 8.51 0.364 9.25 0.459 11.66 0.473 12.01 0.556 14.12 12 AWG (3.29 mm2) 10 AWG (5.32 mm2) Stranding: 65/30 (65 x 0.25 mm) Insulation thickness: 0.012 (0.30 mm) Jacket thickness: 0.035 (0.81 mm) Stranding: 105/30 (105 x 0.25 mm) Insulation thickness: 0.012 (0.30 mm) Jacket thickness: 0.035 (0.81 mm) Part Number Conductors 79037 79038 79039 79040 3 4 5 7 Nominal Diameter Inch mm 0.326 8.28 0.358 9.09 0.392 9.96 0.428 10.87 Part Number Conductors 79041 79042 79043 3 4 5 Nominal Diameter Inch mm 0.38 9.65 0.423 10.74 0.465 11.81 17 EcoFlex® 600 V Control Cable Braid Shield 20 AWG (0.51 mm2) 18 AWG (0.81 mm2) Stranding: 10/30 (10 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.035 (0.89 mm) Stranding: 16/30 (16 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.035 (0.89 mm) Part Number Conductors 79101 79102 79103 79104 79105 79106 79107 79108 2 3 4 5 7 9 12 18 Nominal Diameter Inch mm 0.210 5.33 0.219 5.56 0.233 5.92 0.250 6.35 0.266 6.76 0.321 8.15 0.329 8.36 0.376 9.55 Part Number Conductors 79109 79110 79111 79112 79113 79114 79115 2 3 4 5 7 9 12 Nominal Diameter Inch mm 0.236 5.99 0.247 6.27 0.264 6.71 0.284 7.21 0.305 7.75 0.372 9.45 0.381 9.68 16 AWG (1.32 mm2) 14 AWG (2.08 mm2) Stranding: 26/30 (26 x 0.25 mm) Insulation thickness: 0.011 (0.28 mm) Jacket thickness: 0.035 (0.89 mm) Stranding: 41/30 (41 x 0.25 mm) Insulation thickness: 0.011 (0.28 mm) Jacket thickness: 0.035 (0.81 mm) Part Number Conductors 79116 79117 79118 79119 79120 2 3 4 5 7 Nominal Diameter Inch mm 0.262 6.65 0.275 6.98 0.296 7.52 0.320 8.13 0.345 8.76 Part Number Conductors 79121 79122 79123 79124 79125 2 3 4 5 7 Nominal Diameter Inch mm 0.294 7.47 0.309 7.85 0.335 8.51 0.363 9.22 0.392 9.96 12 AWG (3.29 mm2) Stranding: 65/30 (65 x 0.25 mm) Insulation thickness: 0.012 (0.30 mm) Jacket thickness: 0.035 (0.81 mm) Part Number Conductors 79126 79127 3 4 Nominal Diameter Inch mm 0.354 8.99 0.386 9.80 Supra-Shield® Foil + Braid 18 28 AWG (0.09 mm2) 26 AWG (0.14 mm2) Stranding: 7/36 (7 x 0.13 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.035 (0.89 mm) Stranding: 7/34 (7 x 0.16 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.035 (0.89 mm) Part Number Conductors 79261 79262 2 3 Nominal Diameter Inch mm 0.174 4.42 0.179 4.55 Part Number Conductors 79256 79257 79258 79259 79260 2 3 4 6 8 Nominal Diameter Inch mm 0.182 4.62 0.188 4.78 0.198 5.03 0.221 5.61 0.248 6.30 EcoFlex® 600 V Control Cable Supra-Shield® Foil + Braid (continued) 24 AWG (0.24 mm2) 22 AWG (0.38 mm2) Stranding: 19/36 (19 x 0.13 mm) Insulation thickness: 0.011 (0.25 mm) Jacket thickness: 0.035 (0.89 mm) Stranding: 19/34 (19 x 0.16 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.035 (0.89 mm) Part Number Conductors 79250 79251 79252 79253 79254 79255 2 3 4 6 8 10 Nominal Diameter Inch mm 0.194 4.93 0.201 5.11 0.213 5.41 0.239 6.07 0.27 6.86 0.289 7.34 Part Number Conductors 79244 79245 79246 79247 79248 79249 2 3 4 6 8 10 Nominal Diameter Inch mm 0.208 5.28 0.216 5.49 0.23 5.84 0.26 6.60 0.296 7.52 0.318 8.08 20 AWG (0.51 mm2) 18 AWG (0.81 mm2) Stranding: 10/30 (10 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.035 (0.89 mm) Stranding: 16/30 (16 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Jacket thickness: 0.035 (0.89 mm) Part Number Conductors 79201 79202 79203 79204 79205 79206 79207 79208 2 3 4 5 7 9 12 18 Nominal Diameter Inch mm 0.216 5.49 0.225 5.72 0.239 6.07 0.256 6.50 0.272 6.91 0.328 8.33 0.335 8.51 0.382 9.70 Part Number Conductors 79210 79211 79212 79213 79214 79215 79216 79217 2 3 4 5 7 9 12 18 Nominal Diameter Inch mm 0.242 6.15 0.253 6.43 0.270 6.86 0.290 7.37 0.311 7.90 0.378 9.60 0.387 9.83 0.445 11.30 16 AWG (1.32 mm2) 14 AWG (2.08 mm2) Stranding: 26/30 (26 x 0.25 mm) Insulation thickness: 0.011 (0.28 mm) Jacket thickness: 0.035 (0.89 mm) Stranding: 41/30 (41 x 0.25 mm) Insulation thickness: 0.011 (0.28 mm) Jacket thickness: 0.035 (0.81 mm) Part Number Conductors 79218 79219 79220 79221 79222 79223 79224 2 3 4 5 7 9 12 Nominal Diameter Inch mm 0.268 6.81 0.281 7.14 0.302 7.67 0.326 8.28 0.351 8.92 0.432 10.97 0.443 11.25 Part Number Conductors 79225 79226 79227 79228 79229 79230 79231 2 3 4 5 7 9 12 Nominal Diameter Inch mm 0.300 7.62 0.315 8.00 0.341 8.66 0.369 9.37 0.398 10.11 0.493 12.52 0.507 12.88 12 AWG (3.29 mm2) 10 AWG (5.32 mm2) Stranding: 65/30 (65 x 0.25 mm) Insulation thickness: 0.012 (0.30 mm) Jacket thickness: 0.035 (0.81 mm) Stranding: 105/30 (105 x 0.25 mm) Insulation thickness: 0.012 (0.30 mm) Jacket thickness: 0.035 (0.81 mm) Part Number Conductors 79232 79233 79234 79235 3 4 5 7 Nominal Diameter Inch mm 0.360 9.14 0.391 9.93 0.426 10.82 0.462 11.73 Part Number Conductors 79236 79237 3 4 Nominal Diameter Inch mm 0.419 10.64 0.457 11.61 19 Xtra-Guard® 1 PVC Control Cable Xtra-Guard 1 cable is a highperformance cable for generalpurpose applications. It features a premium-grade PVC insulation and jacket, high maximum operating temperature, and exceptional EMI protection with Supra-Shield® foil + braid shielding. • A  vailable in over 575 standard constructions • High maximum temperature requires less cooling in machine • Ease of routing in small spaces • 28 – 14 AWG • Most constructions available for same-day shipping • Put-ups as small as 100’ Conductors: Stranded tinned copper Insulation: Premium PVC Jacket: Premium PVC Shielding: Unshielded, foil shield, Supra-Shield Voltage: 300 V, 600 V Temperature Range: -30°C to +105°C Availability: 100’, 500’, 1000’ (30.5 m, 152 m, 305 m); Bulk, cut to length Approvals (continued): • • • • • • • • • • Approvals • • • • • • • • • • • UL VW-1 UL 1685 UL AWM 2464 UL AWM 2501 UL AWM 1569 UL AWM 2343 UL AWM 21894 UL AWM 21896 RoHS UL 10002 UL CM UL MTW 60C Oil CSA CMG CSA FT4 CSA TEW CSA AWM I/II A/B CE Sunlight resistant IEC 60332-1/2 Flame Behavior REACH Jacket Colors: Slate, Beige, White, Red, Blue, Black, Green, Yellow, Orange, Custom 300 V Unshielded, Multiconductor 20 28 AWG (0.09 mm2) 26 AWG (0.14 mm2) Stranding: 7/36 (7 x 0.127 mm) Insulation thickness: 0.010 (0.25 mm) Stranding: 7/34 (7 x 0.16 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Conductors 5920 5921 5922 5923 5924 5925 2 3 4 6 7 8 Nominal Diameter Inch mm 0.138 3.51 0.144 3.66 0.153 3.89 0.174 4.42 0.174 4.42 0.185 4.70 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 Part No. Conductors 5666 5667 5668 5669 5670 5671 5672 5673 2 3 4 6 7 8 10 15 Nominal Diameter Inch mm 0.146 3.71 0.152 3.86 0.162 4.11 0.186 4.72 0.186 4.72 0.198 5.03 0.224 5.69 0.248 6.30 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 Xtra-Guard® 1 PVC Control Cable 300 V Unshielded, Multiconductor (continued) 24 AWG (0.23 mm2) 22 AWG (0.35 mm2) Stranding: 7/32 (7 x 0.20 mm) Insulation thickness: 0.010 (0.25 mm) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Conductors 5012C 5013C 5014C 5016C 5018C 5020C 5020/15C 5020/20C 5020/25C 5020/30C 5020/40C 5020/50C 2 3 4 6 8 10 15 20 25 30 40 50 Nominal Diameter Inch mm 0.156 3.96 0.163 4.14 0.175 4.45 0.201 5.11 0.215 5.46 0.244 6.20 0.271 6.88 0.300 7.62 0.332 8.43 0.350 8.89 0.390 9.91 0.429 10.90 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 Part No. Conductors 5002C 5003C 5004C 5006C 5008C 5010C 5010/15C 5010/20C 5010/25C 5010/30C 5010/40C 5010/50C 5010/60C 2 3 4 6 8 10 15 20 25 30 40 50 60 Nominal Diameter Inch mm 0.168 4.27 0.176 4.47 0.189 4.80 0.219 5.56 0.235 5.97 0.268 6.81 0.299 7.59 0.331 8.41 0.368 9.35 0.389 9.88 0.434 11.02 0.478 12.14 0.518 13.16 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 20 AWG (0.56 mm2) 18 AWG (0.81 mm2) Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.016 (0.41 mm) Stranding: 16/30 (16 x 0.25 mm) Insulation thickness: 0.016 (0.41 mm) Part No. Conductors 5052C 5053C 5054C 5056C 5058C 5060C 5060/15C 5060/20C 5060/25C 5060/30C 5060/40C 5060/50C 2 3 4 6 8 10 15 20 25 30 40 50 Nominal Diameter Inch mm 0.208 5.28 0.219 5.56 0.238 6.05 0.280 7.11 0.302 7.67 0.348 8.84 0.391 9.93 0.437 11.10 0.488 12.40 0.517 13.13 0.622 15.80 0.684 17.37 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.053 1.35 0.053 1.35 16 AWG (1.23 mm2) Stranding: 19/0.0117 (19 x 0.29 mm) Insulation thickness: 0.016 (0.41 mm) Part No. Conductors 5072/1C* 5072C 5073/1C* 5073C 5074C 5076C 5078C 5080C 5080/15C 5080/20C 5080/25C 5080/30C 5080/40C 5080/50C 2 2 3 3 4 6 8 10 15 20 25 30 40 50 Nominal Diameter Inch mm 0.250 6.35 0.250 6.35 0.264 6.71 0.264 6.71 0.288 7.32 0.343 8.71 0.372 9.45 0.432 10.97 0.488 12.40 0.547 13.89 0.656 16.66 0.694 17.63 0.775 19.69 0.917 23.29 Part No. Conductors 5062/1C* 2 5062C 5063/1C* 5063C 5064C 5066C 5068C 5070C 5070/15C 5070/20C 5070/25C 5070/30C 5070/40C 5070/50C 5070/60C 2 3 3 4 6 8 10 15 20 25 30 40 50 60 Nominal Diameter Inch mm 0.226 5.74 0.226 0.238 0.238 0.259 0.307 0.332 0.384 0.433 0.484 0.542 0.617 0.688 0.758 0.881 5.74 6.05 6.05 6.58 7.80 8.43 9.75 11.00 12.29 13.77 15.67 17.48 19.25 22.38 Jacket Thickness Inch mm 0.032 0.81 0.032 0.032 0.032 0.032 0.032 0.032 0.032 0.032 0.032 0.032 0.053 0.053 0.053 0.083 0.81 0.81 0.81 0.81 0.81 0.81 0.81 0.81 0.81 0.81 1.35 1.35 1.35 2.11 *Conductors color-coded per international standards: brown, blue, green/yellow. Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.053 0.81 0.053 0.81 0.053 0.81 0.083 2.11 0.083 2.11 *Conductors color-coded per international standards: brown, blue, green/yellow. 21 Xtra-Guard® 1 PVC Control Cable 300 V Unshielded, Multiconductor AWM 2343 24 AWG (0.23 mm2) 22 AWG (0.35 mm2) Stranding: 7/32 (7 x 0.20 mm) Insulation thickness: 0.010 (0.25 mm) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Conductors 5201C 5202C 5203C 5204C 5206C 7 12 15 19 37 Nominal Diameter Inch mm 0.263 6.68 0.313 7.95 0.333 8.46 0.350 8.89 0.438 11.13 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 20 AWG (0.56 mm2) Part No. Conductors 5210/2C 5211C 5212C 5213C 5214C 5214/25C 5215C 5216C 2 7 12 15 19 25 27 37 Nominal Diameter Inch mm 0.230 5.84 0.281 7.14 0.338 8.59 0.361 9.17 0.380 9.65 0.430 10.92 0.438 11.13 0.480 12.19 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Conductors 5220/2C 5220C 5221C 5222C 5223C 5224C 5224/25C 5225C 5226C 2 5 7 12 15 19 25 27 37 Nominal Diameter Inch mm 0.246 6.25 0.288 7.32 0.305 7.75 0.371 9.42 0.398 10.11 0.420 10.67 0.478 12.14 0.487 12.37 0.536 13.61 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 600 V Unshielded, Multiconductor 22 AWG (0.35 mm2) 20 AWG (0.56 mm2) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.032 (0.81 mm) Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.032 (0.81 mm) Part No. Conductors 5402 5404 5405 5409 5409/19 2 4 5 9 19 Nominal Diameter Inch mm 0.318 8.08 0.358 9.09 0.385 9.78 0.473 12.01 0.601 15.27 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 18 AWG (0.81 mm2) Stranding: 16/30 (16 x 0.25 mm) Insulation thickness: 0.032 (0.81 mm) 22 Part No. Conductors 5422 5423 5424 5425 5427 5429 5429/15 5429/19 5429/25 2 3 4 5 7 9 15 19 25 Nominal Diameter Inch mm 0.352 8.94 0.369 9.37 0.399 10.13 0.432 10.97 0.466 11.84 0.535 13.59 0.643 16.33 0.686 17.42 0.796 20.22 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 Part No. Conductors 5413 5414 5419 5419/12 5419/15 5419/19 5419/25 3 4 9 12 15 19 25 Nominal Diameter Inch mm 0.350 8.89 0.377 9.58 0.503 12.78 0.554 14.07 0.601 15.27 0.641 16.28 0.742 18.85 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 Xtra-Guard® 1 PVC Control Cable 600 V Unshielded, Multiconductor (continued) 16 AWG (1.23 mm2) 14 AWG (2.08 mm2) Stranding: 19/0.0117 (19 x 0.29 mm) Insulation thickness: 0.032 (0.81 mm) Stranding: 41/30 (41 x 0.25 mm) Insulation thickness: 0.032 (0.81 mm) Part No. Conductors 5434 5435 5437 5439 5439/12 5439/15 5439/19 5439/25 4 5 7 9 12 15 19 25 Nominal Diameter Inch mm 0.428 10.87 0.464 11.79 0.502 12.75 0.579 14.71 0.641 16.28 0.698 17.73 0.746 18.95 0.908 23.06 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.083 2.11 0.083 2.11 Part No. Conductors 5442 5443 5444 5445 5447 5449 5449/12 5449/15 5449/25 2 3 4 5 7 9 12 15 25 Nominal Diameter Inch mm 0.406 10.31 0.428 10.87 0.464 11.79 0.505 12.83 0.547 13.89 0.634 16.10 0.703 17.86 0.767 19.48 0.998 25.35 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.083 2.11 300 V Foil Shielded, Multiconductor 28 AWG (0.09 mm2) 26 AWG (0.14 mm2) Stranding: 7/36 (7 x 0.127 mm) Insulation thickness: 0.010 (0.25 mm) Stranding: 7/34 (7 x 0.16 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Conductors 5926 5927 5928 5929 5930 5931 2 3 4 6 7 8 Nominal Diameter Inch mm 0.142 3.61 0.148 3.76 0.157 3.99 0.178 4.52 0.178 4.52 0.189 4.80 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 Part No. Conductors 5674 5675 5676 5677 5678 5679 5680 5681 2 3 4 6 7 8 10 15 Nominal Diameter Inch mm 0.150 3.81 0.156 3.96 0.166 4.22 0.190 4.83 0.190 4.83 0.202 5.13 0.228 5.79 0.252 6.40 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 24 AWG (0.23 mm2) 22 AWG (0.35 mm2) Stranding: 7/32 (7 x 0.20 mm) Insulation thickness: 0.010 (0.25 mm) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Conductors 5092C 5093C 5094C 5096C 5098C 5100C 5100/15C 5100/20C 5100/25C 5100/30C 5100/40C 5100/50C 5100/60C 5100/70C 2 3 4 6 8 10 15 20 25 30 40 50 60 70 Nominal Diameter Inch mm 0.160 4.06 0.167 4.24 0.179 4.55 0.205 5.21 0.219 5.56 0.248 6.30 0.275 6.99 0.304 7.72 0.336 8.53 0.354 8.99 0.394 10.01 0.433 11.00 0.468 11.89 0.505 12.83 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 Part No. Conductors 5192C 5193C 5194C 5196C 5198C 5199/10C 5199/15C 5199/20C 5199/25C 5199/30C 5199/40C 5199/50C 5199/60C 5199/70C 2 3 4 6 8 10 15 20 25 30 40 50 60 70 Nominal Diameter Inch mm 0.172 4.37 0.180 4.57 0.193 4.90 0.223 5.66 0.239 6.07 0.272 6.91 0.303 7.70 0.335 8.51 0.372 9.45 0.393 9.98 0.438 11.13 0.482 12.24 0.522 13.26 0.606 15.39 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.053 1.35 23 Xtra-Guard® 1 PVC Control Cable 300 V Foil Shielded, Multiconductor (continued) 20 AWG (0.56 mm2) 18 AWG (0.81 mm2) Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.016 (0.41 mm) Stranding: 16/30 (16 x 0.25 mm) Insulation thickness: 0.016 (0.41 mm) Part No. Conductors 5462C 5463C 5464C 5466C 5468C 5470C 5470/15C 5470/20C 5470/25C 5470/30C 5470/40C 5470/50C 2 3 4 6 8 10 15 20 25 30 40 50 Nominal Diameter Inch mm 0.212 5.38 0.223 5.66 0.242 6.15 0.284 7.21 0.306 7.77 0.352 8.94 0.395 10.03 0.441 11.20 0.492 12.50 0.521 13.23 0.626 15.90 0.688 17.48 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.053 1.35 0.053 1.35 16 AWG (1.23 mm2) Stranding: 19/0.0117 (19 x 0.29 mm) Insulation thickness: 0.016 (0.41 mm) 24 Part No. Conductors 5362C 5362/1C* 5363C 5363/1C* 5364C 5366C 5368C 5370C 5370/15C 5370/20C 5370/25C 5370/30C 5370/40C 2 2 3 3 4 6 8 10 15 20 25 30 40 Nominal Diameter Inch mm 0.254 6.45 0.254 6.45 0.268 6.81 0.268 6.81 0.292 7.42 0.347 8.81 0.376 9.55 0.436 11.07 0.492 12.50 0.593 15.06 0.660 16.76 0.698 17.73 0.779 19.79 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.053 1.35 0.053 1.35 0.053 1.35 0.083 2.11 Part No. Conductors 5382C 5382/1C* 5383C 5383/1C* 5384C 5386C 5388C 5390C 5390/15C 5390/20C 5390/25C 5390/30C 5390/40C 5390/50C 5390/60C 2 2 3 3 4 6 8 10 15 20 25 30 40 50 60 Nominal Diameter Inch mm 0.230 5.84 0.230 5.84 0.242 6.15 0.242 6.15 0.263 6.68 0.311 7.90 0.336 8.53 0.388 9.86 0.437 11.10 0.488 12.40 0.588 14.94 0.621 15.77 0.692 17.58 0.762 19.35 0.885 22.48 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.053 1.35 0.053 1.35 0.053 1.35 0.053 1.35 0.083 2.11 Xtra-Guard® 1 PVC Control Cable 300 V Foil Shielded, Multiconductor AWM 2343 24 AWG (0.23 mm2) 22 AWG (0.35 mm2) Stranding: 7/32 (7 x 0.20 mm) Insulation thickness: 0.010 (0.25 mm) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Conductors 5599/3C 5599/5C 5599/7C 5599/12C 5599/15C 5599/19C 5599/27C 3 5 7 12 15 19 27 Nominal Diameter Inch mm 0.229 5.82 0.254 6.45 0.267 6.78 0.317 8.05 0.337 8.56 0.354 8.99 0.405 10.29 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 Part No. Conductors 5580/2C 5580C 5581C 5582C 5583C 5584C 5586C 2 5 7 12 15 19 37 Nominal Diameter Inch mm 0.234 5.94 0.270 6.86 0.285 7.24 0.342 8.69 0.365 9.27 0.384 9.75 0.484 12.29 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 20 AWG (0.56 mm2) Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Conductors 5560/2C 5560C 5561C 5562C 5563C 5564C 2 5 7 12 15 19 Nominal Diameter Inch mm 0.250 6.35 0.292 7.42 0.309 7.85 0.375 9.53 0.402 10.21 0.424 10.77 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 600 V Foil Shielded, Multiconductor 22 AWG (0.35 mm ) 20 AWG (0.56 mm2) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.032 (0.81 mm) Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.032 (0.81 mm) 2 Part No. Conductors 5410/2 5410/3 5410/4 5410/5 5410/9 5410/12 2 3 4 5 9 12 Nominal Diameter Inch mm 0.322 8.18 0.337 8.56 0.362 9.19 0.389 9.88 0.477 12.12 0.525 13.34 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 Part No. Conductors 5420/3 5420/4 5420/5 5420/7 5420/9 5420/12 3 4 5 7 9 12 Nominal Diameter Inch mm 0.354 8.99 0.381 9.68 0.411 10.44 0.442 11.23 0.507 12.88 0.558 14.17 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 18 AWG (0.81 mm2) 16 AWG (1.23 mm2) Stranding: 16/30 (16 x 0.25 mm) Insulation thickness: 0.032 (0.81 mm) Stranding: 19/0.0117 (19 x 0.29 mm) Insulation thickness: 0.032 (0.81 mm) Part No. Conductors 5430/2 5430/3 5430/4 5430/5 5430/7 5430/9 5430/12 5430/15 5430/19 5430/25 2 3 4 5 7 9 12 15 19 25 Nominal Diameter Inch mm 0.356 9.04 0.373 9.47 0.403 10.24 0.436 11.07 0.470 11.94 0.539 13.69 0.595 15.11 0.647 16.43 0.690 17.53 0.800 20.32 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 Part No. Conductors 5440/2 5440/3 5440/4 5440/5 5440/7 5440/9 5440/12 5440/15 2 3 4 5 7 9 12 15 Nominal Diameter Inch mm 0.380 9.65 0.399 10.13 0.432 10.97 0.468 11.89 0.506 12.85 0.583 14.81 0.645 16.38 0.702 17.83 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 25 Xtra-Guard® 1 PVC Control Cable 600 V Foil Shielded, Multiconductor (continued) 14 AWG (2.08 mm2) Stranding: 41/30 (41 x 0.25 mm) Insulation thickness: 0.032 (0.81 mm) Part No. Conductors 5450/2 5450/3 5450/4 5450/5 5450/7 5450/12 2 3 4 5 7 12 Nominal Diameter Inch mm 0.410 10.41 0.432 10.97 0.468 11.89 0.509 12.93 0.551 14.00 0.707 17.96 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 300 V Supra-Shield® Foil + Braid, Multiconductor 26 28 AWG (0.09 mm2) 26 AWG (0.14 mm2) Stranding: 7/36 (7 x 0.127 mm) Insulation thickness: 0.010 (0.25 mm) Stranding: 7/34 (7 x 0.16 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Conductors 5932 5933 5934 5935 5936 5937 2 3 4 6 7 8 Nominal Diameter Inch mm 0.166 4.22 0.172 4.37 0.181 4.60 0.202 5.13 0.202 5.13 0.213 5.41 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 Part No. Conductors 5682 5683 5684 5685 5686 5687 5688 5689 2 3 4 6 7 8 10 15 Nominal Diameter Inch mm 0.174 4.42 0.180 4.57 0.190 4.83 0.214 5.44 0.214 5.44 0.226 5.74 0.252 6.40 0.276 7.01 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 24 AWG (0.23 mm2) 22 AWG (0.35 mm2) Stranding: 7/32 (7 x 0.20 mm) Insulation thickness: 0.010 (0.25 mm) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Conductors 5112C 5113C 5114C 5116C 5118C 5120C 5120/15C 5120/20C 5120/25C 5120/30C 5120/40C 5120/50C 2 3 4 6 8 10 15 20 25 30 40 50 Nominal Diameter Inch mm 0.184 4.67 0.191 4.85 0.203 5.16 0.229 5.82 0.243 6.17 0.272 6.91 0.299 7.59 0.328 8.33 0.360 9.14 0.378 9.60 0.418 10.62 0.457 11.61 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 Part No. Conductors 5102C 5103C 5104C 5106C 5108C 5110C 5110/15C 5110/20C 5110/25C 5110/30C 5110/40C 5110/50C 5110/60C 5110/70C 5110/80C 2 3 4 6 8 10 15 20 25 30 40 50 60 70 80 Nominal Diameter Inch mm 0.196 4.98 0.204 5.18 0.217 5.51 0.247 6.27 0.263 6.68 0.296 7.52 0.327 8.31 0.359 9.12 0.396 10.06 0.417 10.59 0.462 11.73 0.506 12.85 0.588 14.94 0.630 16.00 0.665 16.89 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 Xtra-Guard® 1 PVC Control Cable 300 V Supra-Shield® Foil + Braid, Multiconductor (continued) 20 AWG (0.56 mm2) 18 AWG (0.81 mm2) Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.016 (0.41 mm) Stranding: 16/30 (16 x 0.25 mm) Insulation thickness: 0.016 (0.41 mm) Part No. Conductors 5152C 5153C 5154C 5156C 5158C 5160C 5160/15C 5160/20C 5160/25C 5160/30C 5160/40C 5160/50C 5160/60C 2 3 4 6 8 10 15 20 25 30 40 50 60 Nominal Diameter Inch mm 0.236 5.99 0.247 6.27 0.266 6.76 0.308 7.82 0.330 8.38 0.376 9.55 0.419 10.64 0.465 11.81 0.516 13.11 0.545 13.84 0.656 16.66 0.718 18.24 0.774 19.66 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.053 1.35 0.053 1.35 0.053 1.35 Part No. Conductors 5162/1C* 5162C 5163/1C* 5163C 5164C 5166C 5168C 5170C 5170/15C 5170/20C 5170/25C 5170/30C 5170/40C 2 2 3 3 4 6 8 10 15 20 25 30 40 Nominal Diameter Inch mm 0.254 6.45 0.254 6.45 0.266 6.76 0.266 6.76 0.287 7.29 0.335 8.51 0.360 9.14 0.412 10.46 0.461 11.71 0.512 13.00 0.612 15.54 0.651 16.54 0.722 18.34 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.053 1.35 0.053 1.35 0.053 1.35 *Conductors color-coded per international standards: brown, blue, green/yellow. 16 AWG (1.23 mm2) Stranding: 19/0.0117 (19 x 0.29 mm) Insulation thickness: 0.016 (0.41 mm) Part No. Conductors 5172/1C* 5172C 5173/1C* 5173C 5174C 5176C 5178C 5180C 5180/15C 5180/20C 5180/25C 2 2 3 3 4 6 8 10 15 20 25 Nominal Diameter Inch mm 0.278 7.06 0.278 7.06 0.292 7.42 0.292 7.42 0.316 8.03 0.371 9.42 0.400 10.16 0.460 11.68 0.516 13.11 0.617 15.67 0.690 17.53 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.053 1.35 0.053 1.35 *Conductors color-coded per international standards: brown, blue, green/yellow. 300 V Supra-Shield® Foil + Braid, Multiconductor AWM 2343 24 AWG (0.23 mm2) 22 AWG (0.35 mm2) Stranding: 7/32 (7 x 0.20 mm) Insulation thickness: 0.010 (0.25 mm) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Conductors 5300C 5301C 5302C 5303C 5304C 5305C 5306C 5307C 5 7 12 15 19 27 37 48 Nominal Diameter Inch mm 0.278 7.06 0.291 7.39 0.341 8.66 0.361 9.17 0.378 9.60 0.429 10.90 0.466 11.84 0.517 13.13 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 Part No. Conductors 5310C 5311C 5312C 5313C 5314C 5316C 5318C 5 7 12 15 19 37 60 Nominal Diameter Inch mm 0.294 7.47 0.309 7.85 0.366 9.30 0.389 9.88 0.408 10.36 0.508 12.90 0.608 15.44 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 27 Xtra-Guard® 1 PVC Control Cable 300 V Supra-Shield® Foil + Braid, Multiconductor AWM 2343 (continued) 20 AWG (0.56 mm2) Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Conductors 5320/4C 5320C 5321C 5322C 5323C 5324C 5325C 5326C 4 5 7 12 15 19 27 37 Nominal Diameter Inch mm 0.299 7.59 0.316 8.03 0.333 8.46 0.399 10.13 0.426 10.82 0.448 11.38 0.515 13.08 0.564 14.33 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 600 V Supra-Shield® Foil + Braid, Multiconductor 22 AWG (0.35 mm2) 20 AWG (0.56 mm2) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.032 (0.81 mm) Stranding: 10/30 (10 x 0.25 mm) Insulation thickness: 0.032 (0.81 mm) Part No. Conductors 5504 5599/5C 5509/12 4 7 12 Nominal Diameter Inch mm 0.386 9.80 0.442 11.23 0.549 13.94 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 Conductors 5514 5517 5519 5519/12 5519/19 4 7 9 12 19 Nominal Diameter Inch mm 0.405 10.29 0.466 11.84 0.531 13.49 0.582 14.78 0.675 17.15 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 18 AWG (0.81 mm2) 16 AWG (1.23 mm2) Stranding: 16/30 (16 x 0.25 mm) Insulation thickness: 0.032 (0.81 mm) Stranding: 19/0.0117 (19 x 0.29 mm) Insulation thickness: 0.032 (0.81 mm) Part No. Conductors 5522 5523 5524 5525 5527 5529 5529/12 5529/15 5529/19 2 3 4 5 7 9 12 15 19 Nominal Diameter Inch mm 0.380 9.65 0.397 10.08 0.427 10.85 0.460 11.68 0.494 12.55 0.563 14.30 0.619 15.72 0.677 17.20 0.760 19.30 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.083 2.11 14 AWG (2.08 mm2) Stranding: 41/30 (41 x 0.25 mm) Insulation thickness: 0.032 (0.81 mm) 28 Part No. Part No. Conductors 5542 5543 5544 5547 5549 5549/12 5549/15 2 3 4 7 9 12 15 Nominal Diameter Inch mm 0.434 11.02 0.456 11.58 0.492 12.50 0.575 14.61 0.668 16.97 0.777 19.74 0.841 21.36 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.083 2.11 0.083 2.11 Part No. Conductors 5532 5533 5534 5535 5537 5539 5539/12 5539/15 5539/19 2 3 4 5 7 9 12 15 19 Nominal Diameter Inch mm 0.404 10.26 0.423 10.74 0.456 11.58 0.492 12.50 0.530 13.46 0.607 15.42 0.675 17.15 0.772 19.61 0.820 20.83 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.083 2.11 Xtra-Guard® 1 PVC Control Cable 300 V Unshielded, Multipair 24 AWG (0.23 mm2) 22 AWG (0.35 mm2) Stranding: 7/32 (7 x 0.20 mm) Insulation thickness: 0.010 (0.25 mm) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Pairs 5261C 5262C 5263C 5264C 5265C 5266C 5269C 5269/11C 5269/15C 5269/27C 5269/77C 1 2 3 4 5 6 9 11 15 27 77 Nominal Diameter Inch mm 0.156 3.96 0.212 5.38 0.224 5.69 0.243 6.17 0.264 6.71 0.286 7.26 0.332 8.43 0.357 9.07 0.401 10.19 0.512 13.00 0.904 22.96 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.083 0.81 Part No. Pairs 5021C 5022C 5023C 5024C 5025C 5026C 5029/15C 1 2 3 4 5 6 15 Nominal Diameter Inch mm 0.168 4.27 0.232 5.89 0.245 6.22 0.267 6.78 0.291 7.39 0.316 8.03 0.447 11.35 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 20 AWG (0.56 mm2) 18 AWG (0.81 mm2) Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.016 (0.41 mm) Stranding: 16/30 (16 x 0.25 mm) Insulation thickness: 0.016 (0.41 mm) Part No. Pairs 5282C 5283C 5286C 5289C 5289/12C 2 3 6 9 12 Nominal Diameter Inch mm 0.298 7.57 0.316 8.03 0.415 10.54 0.487 12.37 0.545 13.84 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 Part No. Pairs 5032C 5033C 5036C 5039C 5039/12C 2 3 6 9 12 Nominal Diameter Inch mm 0.327 8.31 0.348 8.84 0.460 11.68 0.541 13.74 0.648 16.46 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.053 1.35 0.053 1.35 300 V Foil Shield, Multipair 28 AWG (0.09 mm2) 26 AWG (0.14 mm2) Stranding: 7/36 (7 x 0.12 mm) Insulation Thickness: 0.010 (0.25 mm) Stranding: 7/34 (7 x 0.16 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Pairs 5938 5939 5940 5941 5942 2 3 4 5 6 Nominal Diameter Inch mm 0.187 4.75 0.196 4.98 0.211 5.36 0.228 5.79 0.246 6.25 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 Part No. Pairs 5690 5691 5692 5693 5694 2 3 4 5 6 Nominal Diameter Inch mm 0.200 5.08 0.210 5.33 0.227 5.77 0.246 6.25 0.265 6.73 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 24 AWG (0.23 mm2) Stranding: 7/32 (7 x 0.20 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Pairs 5491C 5492C 5493C 5494C 5495C 5496C 5499C 5499/11C 5499/15C 5499/19C 5499/27C 1 2 3 4 5 6 9 11 15 19 27 Nominal Diameter Inch mm 0.160 4.06 0.216 5.49 0.228 5.79 0.247 6.27 0.268 6.81 0.290 7.37 0.336 8.53 0.361 9.17 0.405 10.29 0.433 11.00 0.516 13.11 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 29 Xtra-Guard® 1 PVC Control Cable 300 V Foil Shield, Multipair AWM 2464 30 28 AWG (0.09 mm2) 26 AWG (0.14 mm2) Stranding: 7/36 (7 x 0.12 mm) Insulation Thickness: 0.010 (0.25 mm) Stranding: 7/34 (7 x 0.16 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Pairs 5938 5939 5940 5941 5942 2 3 4 5 6 Nominal Diameter Inch mm 0.187 4.75 0.196 4.98 0.211 5.36 0.228 5.79 0.246 6.25 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 Part No. Pairs 5690 5691 5692 5693 5694 2 3 4 5 6 Nominal Diameter Inch mm 0.200 5.08 0.210 5.33 0.227 5.77 0.246 6.25 0.265 6.73 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 24 AWG (0.23 mm2) 22 AWG (0.35 mm2) Stranding: 7/32 (7 x 0.20 mm) Insulation thickness: 0.010 (0.25 mm) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Pairs 5491C 5492C 5493C 5494C 5495C 5496C 5499C 5499/11C 5499/15C 5499/19C 5499/27C 1 2 3 4 5 6 9 11 15 19 27 Nominal Diameter Inch mm 0.160 4.06 0.216 5.49 0.228 5.79 0.247 6.27 0.268 6.81 0.290 7.37 0.336 8.53 0.361 9.17 0.405 10.29 0.433 11.00 0.516 13.11 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 Part No. Pairs 5481C 5482C 5483C 5484C 5485C 5486C 5489C 5489/11C 5489/15C 5489/19C 5489/27C 1 2 3 4 5 6 9 11 15 19 27 Nominal Diameter Inch mm 0.172 4.37 0.236 5.99 0.249 6.32 0.271 6.88 0.295 7.49 0.320 8.13 0.372 9.45 0.400 10.16 0.451 11.46 0.483 12.27 0.619 15.72 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.053 1.35 20 AWG (0.56 mm2) 18 AWG (0.81 mm2) Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.016 (0.41 mm) Stranding: 16/30 (16 x 0.25 mm) Insulation thickness: 0.016 (0.41 mm) Part No. Pairs 5452C 5453C 5456C 5459C 5459/12C 5459/19C 2 3 6 9 12 19 Nominal Diameter Inch mm 0.302 7.67 0.320 8.13 0.419 10.64 0.491 12.47 0.549 13.94 0.689 17.50 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.053 1.35 Part No. Pairs 5373C 5376C 3 6 Nominal Diameter Inch mm 0.352 8.94 0.464 11.79 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 Xtra-Guard® 1 PVC Control Cable 300 V Supra-Shield® Foil + Braid, Multipair 28 AWG (0.09 mm2) 26 AWG (0.14 mm2) Stranding: 7/36 (7 x 0.12 mm) Insulation Thickness: 0.010 (0.25 mm) Stranding: 7/34 (7 x 0.16 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Pairs 5943 5944 5945 5946 5947 2 3 4 5 6 Nominal Diameter Inch mm 0.211 5.36 0.220 5.59 0.235 5.97 0.252 6.40 0.270 6.86 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 Part No. Pairs 5695 5696 5697 5698 5699 2 3 4 5 6 Nominal Diameter Inch mm 0.224 5.69 0.234 5.94 0.251 6.38 0.270 6.86 0.289 7.34 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 24 AWG (0.23 mm2) 22 AWG (0.35 mm2) Stranding: 7/32 (7 x 0.20 mm) Insulation thickness: 0.010 (0.25 mm) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Pairs 5271C 5272C 5273C 5274C 5275C 5276C 5279C 5279/11C 5279/15C 5279/19C 5279/27C 5279/51C 1 2 3 4 5 6 9 11 15 19 27 51 Nominal Diameter Inch mm 0.184 4.67 0.240 6.10 0.252 6.40 0.271 6.88 0.292 7.42 0.314 7.98 0.360 9.14 0.385 9.78 0.429 10.90 0.457 11.61 0.540 13.72 0.739 18.77 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.053 1.35 Part No. Pairs 5121C 5122C 5123C 5124C 5125C 5126C 5129C 5129/11C 5129/15C 5129/19C 5129/27C 1 2 3 4 5 6 9 11 15 19 27 Nominal Diameter Inch mm 0.196 4.98 0.260 6.60 0.273 6.93 0.295 7.49 0.319 8.10 0.344 8.74 0.396 10.06 0.424 10.77 0.475 12.07 0.507 12.88 0.649 16.48 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.053 1.35 20 AWG (0.56 mm2) 18 AWG (0.81 mm2) Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.016 (0.41 mm) Stranding: 16/30 (16 x 0.25 mm) Insulation thickness: 0.016 (0.41 mm) Part No. Pairs 5292C 5293C 5296C 5299C 5299/19C 2 3 6 9 19 Nominal Diameter Inch mm 0.326 8.28 0.344 8.74 0.443 11.25 0.515 13.08 0.719 18.26 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.053 1.35 Part No. Pairs 5132C 5133C 5136C 5139C 5139/27C 2 3 6 9 27 Nominal Diameter Inch mm 0.355 9.02 0.376 9.55 0.488 12.40 0.611 15.52 1.004 25.50 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.053 1.35 0.083 2.11 31 Xtra-Guard® 1 PVC Control Cable 300 V Supra-Shield® Foil + Braid, Multipair AWM2343 24 AWG (0.23 mm2) 22 AWG (0.35 mm2) Stranding: 7/32 (7 x 0.20 mm) Insulation thickness: 0.010 (0.25 mm) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Pairs 5330C 5331C 5332C 5333C 5334C 5335C 5336C 5 7 12 15 19 27 37 Nominal Diameter Inch mm 0.354 8.99 0.376 9.55 0.458 11.63 0.491 12.47 0.519 13.18 0.602 15.29 0.669 16.99 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 20 AWG (0.56 mm2) Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.010 (0.25 mm) 32 Part No. Pairs 5350/4C 5350C 5351C 5351/9C 5353C 5354C 5355C 4 5 7 9 15 19 27 Nominal Diameter Inch mm 0.388 9.86 0.416 10.57 0.446 11.33 0.505 12.83 0.597 15.16 0.634 16.10 0.749 19.02 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 Part No. Pairs 5340/2C 5340C 5341C 5342C 5344C 5345C 5346C 2 5 7 12 19 27 37 Nominal Diameter Inch mm 0.322 8.18 0.381 9.68 0.406 10.31 0.499 12.67 0.569 14.45 0.669 16.99 0.738 18.75 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 Xtra-Guard® 5 Performance Cable Jacket: FEP Xtra-Guard 5 cable is an extremeperformance cable featuring FEP insulation and jacketing for reliable performance in temperatures from -80°C to +200°C. It’s also chemical resistant to withstand the most hazardous environments. Shielding: Unshielded, foil shield, Supra-Shield Voltage: 300 V Temperature Range: -80°C to +200°C Availability: Made to order; 1000’ (305 m) minimum • S  uperior oil, solvent, and chemical resistance • Exceptional EMI protection with Supra-Shield® Foil + Braid • 24 – 16 AWG Approvals (continued): • RoHS • REACH Approvals • • • • • Conductors: Tinned copper Insulation: FEP CE CSA CMP CSA FT6 UL AWM 20229 UL CMP Jacket Colors: Slate, Beige, White, Red, Blue, Black, Green, Yellow, Orange, Custom 300 V Unshielded, Multiconductor 24 AWG (0.23 mm2) 22 AWG (0.35 mm2) Stranding: 7/32 (7 x 0.20 mm) Insulation thickness: 0.010 (0.25 mm) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Conductors 55012 55013 55014 55016 55019 55020/12 2 3 4 6 9 12 Nominal Diameter Inch mm 0.148 3.76 0.155 3.94 0.166 4.22 0.193 4.90 0.220 5.59 0.243 6.17 Jacket Thickness Inch mm 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 Part No. Conductors 55002 55003 55004 55006 55009 55010/12 2 3 4 6 9 12 Nominal Diameter Inch mm 0.160 4.06 0.168 4.27 0.181 4.60 0.211 5.36 0.242 6.15 0.268 6.81 Jacket Thickness Inch mm 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 20 AWG (0.56 mm2) 18 AWG (0.90 mm2) Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.010 (0.25 mm) Stranding: 7/26 (7 x 0.40 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Conductors 55052 55053 55054 55056 55059 55060/12 2 3 4 6 9 12 Nominal Diameter Inch mm 0.176 4.47 0.185 4.70 0.200 5.08 0.235 5.97 0.271 6.88 0.301 7.65 Jacket Thickness Inch mm 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 Part No. Conductors 55062 55063 55064 55066 55069 55070/12 2 3 4 6 9 12 Nominal Diameter Inch mm 0.196 4.98 0.207 5.26 0.225 5.72 0.265 6.73 0.307 7.80 0.343 8.71 Jacket Thickness Inch mm 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 16 AWG (1.23 mm2) Stranding: 19/0.0117 (19 x 0.29 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Conductors 55072 55073 55074 55076 55079 55080/12 2 3 4 6 9 12 Nominal Diameter Inch mm 0.218 5.54 0.230 5.84 0.251 6.38 0.298 7.57 0.347 8.81 0.388 9.86 Jacket Thickness Inch mm 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 33 Xtra-Guard® 5 Performance Cable 300 V Foil Shield, Multiconductor 24 AWG (0.23 mm2) 22 AWG (0.35 mm2) Stranding: 7/32 (7 x 0.20 mm) Insulation thickness: 0.010 (0.25 mm) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Conductors 55092 55093 55094 55096 55099 55100/12 2 3 4 6 9 12 Nominal Diameter Inch mm 0.154 3.91 0.161 4.09 0.172 4.37 0.199 5.05 0.226 5.74 0.249 6.32 Jacket Thickness Inch mm 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 Conductors 55192 55193 55194 55196 55199 55199/12 2 3 4 6 9 12 Nominal Diameter Inch mm 0.166 4.22 0.174 4.42 0.187 4.75 0.217 5.51 0.248 6.30 0.274 6.96 Jacket Thickness Inch mm 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 20 AWG (0.56 mm2) 18 AWG (0.90 mm2) Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.010 (0.25 mm) Stranding: 7/26 (7 x 0.40 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Conductors 55462 55463 55464 55466 55469 55470/12 2 3 4 6 9 12 Nominal Diameter Inch mm 0.182 4.62 0.191 4.85 0.206 5.23 0.241 6.12 0.277 7.04 0.307 7.80 Jacket Thickness Inch mm 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 16 AWG (1.23 mm2) Stranding: 19/0.0117 (19 x 0.29 mm) Insulation thickness: 0.010 (0.25 mm) 34 Part No. Part No. Conductors 55362 55363 55364 55366 55369 55370/12 2 3 4 6 9 12 Nominal Diameter Inch mm 0.224 5.69 0.236 5.99 0.257 6.53 0.304 7.72 0.353 8.97 0.394 10.01 Jacket Thickness Inch mm 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 Part No. Conductors 55382 55383 55384 55386 55389 55390/12 2 3 4 6 9 12 Nominal Diameter Inch mm 0.202 5.13 0.213 5.41 0.231 5.87 0.271 6.88 0.313 7.95 0.349 8.86 Jacket Thickness Inch mm 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 Xtra-Guard® 5 Performance Cable 300 V Supra-Shield® Foil + Braid, Multiconductor 24 AWG (0.23 mm2) 22 AWG (0.35 mm2) Stranding: 7/32 (7 x 0.20 mm) Insulation thickness: 0.010 (0.25 mm) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Conductors 55112 55113 55114 55116 55119 55120/12 2 3 4 6 9 12 Nominal Diameter Inch mm 0.176 4.47 0.183 4.65 0.194 4.93 0.221 5.61 0.248 6.30 0.271 6.88 Jacket Thickness Inch mm 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 Part No. Conductors 55102 55103 55104 55106 55109 55110/12 2 3 4 6 9 12 Nominal Diameter Inch mm 0.188 4.78 0.196 4.98 0.209 5.31 0.239 6.07 0.270 6.86 0.296 7.52 Jacket Thickness Inch mm 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 20 AWG (0.56 mm2) 18 AWG (0.90 mm2) Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.010 (0.25 mm) Stranding: 7/26 (7 x 0.40 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Conductors 55152 55153 55154 55156 55159 55160/12 2 3 4 6 9 12 Nominal Diameter Inch mm 0.204 5.18 0.213 5.41 0.228 5.79 0.263 6.68 0.299 7.59 0.329 8.36 Jacket Thickness Inch mm 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 Part No. Conductors 55162 55163 55164 55166 55169 55170/12 2 3 4 6 9 12 Nominal Diameter Inch mm 0.224 5.69 0.235 5.97 0.253 6.43 0.293 7.44 0.335 8.51 0.371 9.42 Jacket Thickness Inch mm 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 16 AWG (1.23 mm2) Stranding: 19/0.0117 (19 x 0.29 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Conductors 55172 55173 55174 55176 55179 55180/12 2 3 4 6 9 12 Nominal Diameter Inch mm 0.246 6.25 0.258 6.55 0.279 7.09 0.326 8.28 0.375 9.53 0.416 10.57 Jacket Thickness Inch mm 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 300 V Unshielded, Multipair 22 AWG (0.35 mm ) 2 Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Pairs 55021 55022 55023 55026 55029 55029/12 1 2 3 6 9 12 Nominal Diameter Inch mm 0.160 4.06 0.224 5.69 0.237 6.02 0.307 7.80 0.358 9.09 0.401 10.19 Jacket Thickness Inch mm 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 35 Xtra-Guard® 5 Performance Cable 300 V Foil Shield, Multipair 24 AWG (0.23 mm2) 22 AWG (0.35 mm2) Stranding: 7/32 (7 x 0.20 mm) Insulation thickness: 0.010 (0.25 mm) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Pairs 55491 55492 55493 55496 55499 55499/11 1 2 3 6 9 11 Nominal Diameter Inch mm 0.154 3.91 0.210 5.33 0.222 5.64 0.284 7.21 0.329 8.36 0.355 9.02 Jacket Thickness Inch mm 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 Part No. Pairs 55481 55482 55483 55486 55489 55489/12 1 2 3 6 9 12 Nominal Diameter Inch mm 0.166 4.22 0.230 5.84 0.243 6.17 0.313 7.95 0.364 9.25 0.407 10.34 Jacket Thickness Inch mm 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 20 AWG (0.56 mm2) 18 AWG (0.90 mm2) Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.010 (0.25 mm) Stranding: 7/26 (7 x 0.40 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Pairs 55451 55452 55453 55455 55456 55459 55459/12 1 2 3 5 6 9 12 Nominal Diameter Inch mm 0.182 4.62 0.256 6.50 0.271 6.88 0.324 8.23 0.353 8.97 0.412 10.46 0.461 11.71 Jacket Thickness Inch mm 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 Part No. Pairs 55371 55372 55373 55376 55379 1 2 3 6 9 Nominal Diameter Inch mm 0.202 5.13 0.289 7.34 0.306 7.77 0.402 10.21 0.472 11.99 Jacket Thickness Inch mm 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 300 V Supra-Shield® Foil + Braid, Multipair 24 AWG (0.23 mm ) 22 AWG (0.35 mm2) Stranding: 7/32 (7 x 0.20 mm) Insulation thickness: 0.010 (0.25 mm) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) 2 36 Part No. Pairs 55271 55272 55273 55276 55279 55279/12 1 2 3 6 9 12 Nominal Diameter Inch mm 0.176 4.47 0.232 5.89 0.244 6.20 0.306 7.77 0.351 8.92 0.388 9.86 Jacket Thickness Inch mm 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 Part No. Pairs 55121 55122 55123 55126 55129 55129/12 1 2 3 6 9 12 Nominal Diameter Inch mm 0.188 4.78 0.252 6.40 0.265 6.73 0.335 8.51 0.386 9.80 0.429 10.90 Jacket Thickness Inch mm 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 20 AWG (0.56 mm2) 18 AWG (0.90 mm2) Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.010 (0.25 mm) Stranding: 7/26 (7 x 0.40 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Pairs 55291 55292 55293 55296 55299 55299/12 1 2 3 6 9 12 Nominal Diameter Inch mm 0.204 5.18 0.278 7.06 0.293 7.44 0.375 9.53 0.434 11.02 0.483 12.27 Jacket Thickness Inch mm 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 Part No. Pairs 55131 55132 55133 55136 55139 1 2 3 6 9 Nominal Diameter Inch mm 0.224 5.69 0.311 7.90 0.328 8.33 0.424 10.77 0.504 12.80 Jacket Thickness Inch mm 0.027 0.69 0.027 0.69 0.027 0.69 0.027 0.69 0.032 0.81 Hook-Up Wire The broad range of hook-up wire from Alpha Wire means you will find the wire exactly suited to your application. • S  tranded and solid copper conductors, bare or tinned • Color-coded insulation for easy circuit identification • -40°C to +105°C temperature range • Good abrasion resistance • Excellent flame resistance • U  L, CSA compliance • Convenient put-ups as short as 100 feet • Excellent uniformity for easy handling, stripping, and termination EcoWire® 600 V mPPE Wire Innovative EcoWire combines increased performance with a minimized environmental impact. EcoWire’s modified polyphenylene ether (mPPE) insulation is inherently lighter, tougher, and more durable than PVC. Part No. 6710 6711 6712 6713 6714 6715 6715S 6716 6717 6717S 6718 6719 Conductor Size AWG mm2 28 0.08 26 0.13 24 0.20 22 0.32 20 0.52 18 0.82 18 0.82 16 1.30 14 2.08 14 2.08 12 3.30 10 5.26 Stranding AWG mm 7/36 7 x 0.12 7/34 7 x 0.16 7/32 7 x 0.20 7/30 7 x 0.25 10/30 10 x 0.25 16/30 16 x 0.25 Solid Solid 26/30 26 x 0.25 41/30 41 x 0.25 Solid Solid 65/30 65 x 0.25 105/30 105 x 0.25 Insulation Thickness Inch mm 0.010 0.25 0.010 0.25 0.010 0.25 0.010 0.25 0.010 0.25 0.010 0.25 0.010 0.25 0.011 0.28 0.011 0.28 0.011 0.28 0.012 0.30 0.012 0.30 Wire Diameter Inch mm 0.034 0.86 0.038 0.97 0.043 1.09 0.049 1.24 0.055 1.40 0.067 1.70 0.059 1.50 0.081 2.06 0.096 2.44 0.086 2.18 0.117 2.97 0.142 3.66 The result is UL AWM wire that is up to 45% smaller in diameter and 40% lighter than PVC-based counterparts. Plus, the non-halogenated insulation contains no heavy metal pigments, allowing White, Black, Red, Green, Yellow, Blue, Brown, Orange, Slate, Violet, Yellow/Green, Dark Blue it to help manufacturers meet Waste Electrical and Electronic Equipment • -40°C to +105°C (WEEE) requirements. • S  tranded or solid tinned UL AWM 11028 VW-1 CSA AWM I A/B FT1 RoHS REACH Halogen Free CE copper conductors • M  odified polyphenylene ether insulation Availability 100 ft (30.5 m) 1000 ft (305 m) 5000 ft (1524 m) 25,000 ft (7620 m) drum 37 250 V, PTFE Wire MIL-DTL-16878/6 (Type ET) UL VW-1 NEMA HP3 • - 60°C to +200°C • Stranded or solid silverplated copper conductor • PTFE insulation Availability 100 ft (30.5 m) 1000 ft (305 m)** **May contain multiple lengths Part No. 33201 2840/7* 2841/7* 2841/1* 2842/7* 2842/19* 2842/1* 2843/7* 2843/19* 2843/1* 2844/7* 2844/19* 2845/7 2845/19 Wire Size AWG 32 32 30 30 28 28 28 26 26 26 24 24 22 22 mm2 0.03 0.03 0.06 0.05 0.09 0.09 0.08 0.14 0.15 0.13 0.23 0.24 0.35 0.38 Stranding AWG Solid 7/40 7/38 Solid 7/36 19/40 Solid 7/34 19/38 Solid 7/32 19/36 7/30 19/34 mm 1 x 0.20 7 x 0.08 7 x 0.10 1 x 0.25 7 x 0.12 19 x 0.08 1 x 0.32 7 x 0.16 19 x 0.10 1 x 0.40 7 x 0.20 19 x 0.13 7 x 0.25 19 x 0.16 Insulation Thickness Inch mm 0.006 0.15 0.006 0.15 0.006 0.15 0.006 0.15 0.006 0.15 0.006 0.15 0.006 0.15 0.006 0.15 0.006 0.15 0.006 0.15 0.006 0.15 0.006 0.15 0.006 0.15 0.005 0.13 Nominal Diameter Inch mm 0.019 0.48 0.022 0.56 0.024 0.61 0.022 0.56 0.027 0.69 0.027 0.69 0.025 0.64 0.031 0.79 0.031 0.79 0.028 0.71 0.036 0.91 0.036 0.91 0.042 1.07 0.042 1.07 NEMA HP3 Type Colors — ETXBAB ETXBBB ETXBBA ETXBCB ETXBCE ETXBCA ETXBDB ETXBDE ETXBDA ETXBEB ETXBEE ETXBFB ETXBFE Z2 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 Z1 *Not VW-1 Z1 Insulation Colors: 1 White • 2 Black • 3 Red • 4 Green • 5 Yellow • 6 Blue • 7 Brown • 8 Orange • 9 Slate • 10 Violet Z2 Insulation Colors: 0 Black • 1 Brown • 2 Red • 3 Orange • 4 Yellow • 5 Green • 6 Blue • 7 Violet • 8 Slate • 9 White *These wires also available in 500 ft (152 m) put-ups. 600 V, PTFE Wire MIL-DTL-16878/4 (Type E) (600 V) UL AWM 1213* NEMA HP3 *Voltage rating not specified. • - 60°C to +200°C (MIL) • -60°C to +105°C (UL) • Stranded or solid silverplated copper conductor • PTFE insulation Availability 100 ft (30.5 m) 1000 ft (305 m)** **May contain multiple lengths Part No. 5851 5852 5853 5853/19 2853/1 5854 5854/7 2854/1 5855 5855/7 2855/1 5856 5856/7 2856/1*** 5857 2857/1*** 5858 5859† 5859/12† 5859/10† Wire Size AWG 30 28 26 26 26 24 24 24 22 22 22 20 20 20 18 18 16 14 12 10 Stranding mm 0.06 0.09 0.14 0.15 0.13 0.24 0.23 0.20 0.38 0.35 0.32 0.62 0.56 0.52 0.96 0.82 1.23 1.94 3.08 4.74 2 AWG 7/38 7/36 7/34 19/38 Solid 19/36 7/32 Solid 19/34 7/30 Solid 19/32 7/28 Solid 19/30 Solid 19/29 19/27 19/25 37/26 mm 7 x 0.10 7 x 0.13 7 x 0.16 19 x 0.10 1 x 0.40 19 x 0.13 7 x 0.20 1 x 0.51 19 x 0.16 7 x 0.25 1 x 0.64 19 x 0.20 7 x 0.32 1 x 0.81 19 x 0.25 1 x 1.02 19 x 0.29 19 x 0.36 19 x 0.45 37 x 0.40 Insulation Thickness Inch mm 0.010 0.25 0.010 0.25 0.010 0.25 0.010 0.25 0.010 0.25 0.010 0.25 0.010 0.25 0.010 0.25 0.010 0.25 0.010 0.25 0.010 0.25 0.010 0.25 0.010 0.25 0.010 0.25 0.010 0.25 0.011 0.27 0.012 0.30 0.012 0.30 0.012 0.30 0.012 0.30 Nominal Diameter Inch mm 0.032 0.81 0.035 0.89 0.039 0.99 0.039 0.99 0.036 0.91 0.044 1.12 0.044 1.12 0.040 1.02 0.050 1.27 0.050 1.27 0.045 1.14 0.058 1.47 0.058 1.47 0.052 1.32 0.069 1.75 0.061 1.55 0.080 2.03 0.095 2.41 0.114 2.90 0.134 3.40 ***White, black, red only. †Colors 1-5 only, not UL AWM 1213. Insulation Colors: White • Black • Red • Green • Yellow • Blue • Brown • Orange • Slate • Violet 38 NEMA HP3 Type EXBBB EXBCB EXBDB EXBDE EXBDA EXBEE EXBEB EXBEA EXBFE EXBFB EXBFA EXBGE EXBGB EXBGA EXBHE EXBHA EXBJE EXBKE EXBLE EXBMG 1000/300 V, PTFE Wire MIL-DTL-16878/5 (TYPE EE) (1000V) UL AWM 1180 (300V) NEMA HP3 • - 60°C to +200°C • Stranded or solid silverplated copper conductor • PTFE insulation Availability 100 ft (30.5 m) 1000 ft (305 m)** **May contain multiple lengths Part No. 5874 5875 5876 5877 5878 5879 5879/10 5879/12 5879/8* Wire Size AWG 24 22 20 18 16 14 10 12 8 mm2 0.24 0.38 0.62 0.96 1.23 1.94 4.74 3.08 8.61 Stranding AWG 19/36 19/34 19/32 19/30 19/29 19/27 37/26 19/25 133/29 mm 19 x 0.13 19 x 0.16 19 x 0.20 19 x 0.25 19 x 0.29 19 x 0.36 37 x 0.40 19 x 0.45 133 x 0.29 Insulation Thickness Inch mm 0.015 0.37 0.014 0.36 0.014 0.36 0.015 0.37 0.016 0.41 0.017 0.43 0.017 0.43 0.017 0.43 0.020 0.51 Nominal Diameter Inch mm 0.054 1.37 0.060 1.52 0.068 1.73 0.079 2.01 0.089 2.26 0.106 2.69 0.145 3.68 0.125 3.18 0.209 5.31 NEMA HP3 Type EEXBEE EEXBFE EEXBGE EEXBHE EEXBJE EEXBKE EEXBMG EEXBLE EEXBNL *Not UL AWM 1180. Insulation Colors: White • Black • Red • Green • Yellow • Blue • Brown • Orange • Slate • Violet Parts 5878, 5879, 5879/8, 5879/10, 5879/12: white only. 600 V, ETFE or PTFE Wire SAE AS22759/11 (MIL-DTL-22759/11) SAE AS22759/16 (MIL-DTL-22759/16) • - 55°C to +200°C (PTFE) • -55°C to +150°C (ETFE) • Stranded silver-plated copper conductors (SAE AS22759/11) • Stranded tinned copper conductor (SAE AS22759/16) • ETFE or PTFE insulation PTFE, SAE AS22759/11, -55°C to +200°C, Silver-Plated Copper Conductors Insulation Wire Size Stranding Thickness Part No. AWG mm Inch mm AWG mm2 AT261938 26 0.15 19/38 19 x 0.10 0.010 0.25 AT241936 24 0.24 19/36 19 x 0.13 0.009 0.23 AT221934 22 0.38 19/34 19 x 0.16 0.009 0.23 AT201932 20 0.62 19/32 19 x 0.20 0.011 0.28 AT181930 18 0.96 19/30 19 x 0.25 0.010 0.25 AT161929 16 1.23 19/29 19 x 0.29 0.010 0.25 AT141927 14 1.94 19/27 19 x 0.36 0.011 0.27 AT121925 12 3.08 19/25 19 x 0.45 0.013 0.32 Nominal Diameter Inch mm 0.038 0.97 0.043 1.09 0.049 1.24 0.058 1.47 0.068 1.73 0.075 1.90 0.090 2.29 0.111 2.82 Availability 100 ft (30.5 m) 1000 ft (305 m)* *May contain multiple lengths ETFE, SAE AS22759/16, -55°C to +150°C, Tinned Copper Conductors Part No. AZ241936 AZ221934 AZ201932 AZ181930 AZ161929 AZ141927 AZ123728 Wire Size AWG 24 22 20 18 16 14 12 mm2 0.24 0.38 0.62 0.96 1.23 1.94 2.97 Stranding AWG 19/36 19/34 19/32 19/30 19/29 19/27 37/28 mm 19 x 0.13 19 x 0.16 19 x 0.20 19 x 0.25 19 x 0.29 19 x 0.36 37 x 0.32 Insulation Thickness Inch mm 0.011 0.27 0.011 0.28 0.011 0.28 0.012 0.29 0.013 0.33 0.013 0.33 0.014 0.34 Nominal Diameter Inch mm 0.045 1.14 0.052 1.32 0.060 1.52 0.071 1.80 0.079 2.01 0.093 2.36 0.114 2.90 Insulation Colors: White • Black • Red • Green • Yellow • Blue • Brown • Orange • Slate • Violet 39 FIT® Heat Shrink Tubing Alpha Wire offers a broad range of FIT heat-shrink tubing and sleeving products with excellent physical characteristics, used as a reliable way to protect, organize, identify, repair, and seal terminations, provide strain relief, and provide additional mechanical ruggedness. • C  hemical, heat and abrasion resistance • Choice of standard or custom colors 40 • Can seal terminations or provide strain relief • Standard and dual-wall polyolefin tubing • Special purpose • Irradiated or cross-linked materials • Unlined and adhesive lined • -75°C to +360°C temperature range • 2:1 to 6:1 shrink rations • 25’, 100’, 500’, 1000’ (7.6 m, 30.5 m, 152 m, 305 m) lengths Low Outgassing FIT® Heat-Shrink Tubing UL VW-1 Resistance Material Purpose Thin-wall irradiated polyolefin LSZH: reduced smoke generation and gas emission 4 4 Irradiated polyolefin Variety of shrink-ratios 4 4 Chemical Heat Abrasion Flexibility Operating Temperature Shrink Ratio FIT Family -55 to +105°C 2:1 FIT-221L -55 to +135°C 2:1 FIT-221 -55 to +150°C 2:1 FIT-350 Single-Wall Irradiated Polyolefin for General-Purpose Use 4 Special-Application Tubing Irradiated PVDF High shrink temp; 3x tensile strength of standard polyolefin FEP High shrink temp; thin wall thickness 4 -75 to +200°C 1.2:1 FIT-400 PTFE High shrink temp; thin wall thickness 4 -75 to +260°C 1.5:1 FIT-500 Chlorinated polyolefin Oil resistant -75 to +121°C 2:1 FIT-600 Flexible fluoroelastomer High shrink temp -40 to +200°C 2:1 FIT-650 4 4 4 4 4 4 4 4 4 Flexible PTFE Tubing TFT-200 Thin-Wall Tubing TFT-250 Standard-Wall Tubing To improve the reliability of cable harnesses, PTFE tubing provides heat-, chemical-, and abrasionresistant wire protection under the most adverse conditions. With low outgassing, exceptional abrasion resistance, and excellent dielectric properties, it maintains flexibility over its entire temperature range from -75°C to +260°C. ASTM D 3295-81a Type I Class B (TFT-200) ASTM D 3295-81a Type I Class C (TFT-250) AMS 3655 (TFT-200) MIL-I-22129 (TFT-250) 41 FIT® Wire Management Better Wire Management Means Better Harnesses Bringing order to wire harnesses and cable routing means a system that is more reliable, easier to fabricate, and simpler to maintain. Let Alpha Wire help you solve wire management problems. Need additional protection from abrasion? Our woven sleeves are tough and flexible. For additional resistance to chemicals, oils, and solvents, our flexible tubing offers exceptional performance and operates at temperatures as high as 260°C. Our braided shields are effective and easy to use for additional EMI protection or a ground connection. FIT Wire Management Applications include: • • • • • Harnessing Routing Organizing Shielding Grounding Sleeving Alpha has a sleeving for your application with options that are great for flexible wire harnesses, heat protection, and defense against chemicals or abrasion. Tubing Offering protection from flammability, high heat, abrasion, and chemicals, Alpha tubing has the size for your wire and cable routing needs. Braid Alpha braid is an exceptional, low resistance way to create a point-to-point ground strap. In retrofit applications, braid is an ideal way to install additional shielding to your cable. Lacing Tape Lacing tape is a great, economical way to easily bundle wire and cable. Available in many different military grade finishes and colors. Tapes Alpha Wire has two types of tapes for your wire management needs: EMI tape and self-adhering silicone tape. Fiberglass Sleeving FIT Braided Fiberglass Sleeving 42 Material Acrylic coated Feature Chemical resistant PVC coated General purpose Silicone coated Extreme abrasion resistance Uncoated Extreme temperatures Characteristics -30°C to +155°C -20°C to +130°C High temperature, abrasion, and oil resistance Resists fraying, bending, and knotting -70°C to +200°C Highly flexible routing Extreme abrasion resistance Superior electrical properties -60°C to +648°C Extreme flexibility Extreme heat environments FIT Family AF-155 PIF-130 PIF-200 PIF-240 Tubing FIT General-Purpose Tubing Material Feature PVC Multipurpose PVC tubing Nylon connectors Flexible, liquid tight PTFE Thin wall Standard wall PE, Nylon, PTFE, PVC Spiral wrap PE tubing PP fittings Convoluted slit loom Characteristics -20°C to +105°C Flexible wire protection for harnesses and ground straps 37 sizes from 0.022” to 2.5” -18°C to +50°C Maximum flexibility Usable in extremely tight quarters -75°C to +260°C Excellent heat and chemical resistance Flexible wire protection for harnesses and ground straps Resistance to heat, oil, and abrasion Wide range of materials, temperature ranges, and mechanical properties -40°C to +93°C Abrasion and fluid resistant Light weight Easy, flexible cable breakouts FIT Family PVC-105 FNT SLC/RLC TFT-200 TFT-250 SW Type 492 Woven Sleeving Material Feature Polyester General purpose PET Non-fraying PET Wrappable Nylon polyamide Advanced protection PPS Advanced chemical resistance Nylon Maximum protection PTFE Extreme protection PET Wrappable with hook and loop closure FIT Expandable Woven Sleeving Characteristics -75°C to +125°C Good abrasion and cut-through resistance Flame resistant (110) and flame retardant (120) versions -75°C to +125°C Good abrasion and cut-through resistance Flame resistant (110) and flame retardant (120) versions -70°C to +125°C Bends tightly without distorting or opening Easy to install NF = flame retardant -45°C to +150°C Extreme abrasion resistance without losing flexibility or durability Resists fuels, solvents, salt water, chemicals, and UV rays Expandable to 150% -70°C to +200°C Resists acids, bases, solvents, and fuels Extremely lightweight -60°C to +150°C Superior abrasion resistance Smooth inner wall to prevent internal abrasion damage Resists fuels, solvents, salt water, chemicals, and UV rays -70°C to +280°C Cut and abrasion resistant Resists virtually all chemicals and UV rays Thermally stable Low outgassing -75°C to +125°C Unlimited breakouts Abrasion and cut-through resistance Oil and solvent resistance FIT Family GRP-110 GRP-120 GRP-110NF GRP-120NF GRP-130 GRP-130NF GRP-160 GRP-170 GRP-180 GRP-200 ZIP-GRP FIT Non-Expandable Woven Sleeving Material Feature PET Heavy duty Nylon General purpose Nylon Maximum protection Characteristics FIT Family -70°C to +125°C XS-100HD -45°C to +120°C Tightly woven Excellent abrasion resistance and durability -45°C to +120°C Excellent abrasion resistance Tightly woven Deflects high-pressure hose ruptures Resists fuels, chemicals, UV, rot, and vermin Smooth inner wall to prevent internal abrasion damage XS-200N XS-300 43 The cables you trust. The service you deserve. Every application is critical and wire failure is not an option when the safety of equipment and personnel is paramount. Specify Alpha wire, cable, and accessories for precise semiconductor applications, since the integrity of your system is only as robust as the products you use. Custom cable is standard Alpha Wire goes one step further: manufacturing custom cables to meet unique applications—offering specific conductor counts, shielding options, jacket materials, and versatile product designs. Service and support, second-to-none Selecting the correct cable for your critical application is essential to overall system reliability, performance, and safety. So we make it easy for you to select the right Alpha cable for your specific application. Our online resources include a wire and cable selection guide, technical information, full product catalog, and a distributor locator to make it easy to select and get the cable you need. Can’t find what you’re looking for? Design the cable to your specification. It’s easy, just visit www.alphawire.com! GLOBAL HEADQUARTERS 711 Lidgerwood Avenue Elizabeth, NJ 07207-0711 USA Toll Free: 1-800-52 ALPHA Tel: 1-908-925-8000 Fax: 1-908-925-5411 E-mail: [email protected] EUROPE Alpha Wire International Saxon House 1 Downside | Sunbury-on-Thames Middlesex | United Kingdom | TW16 6RT Tel: 01 932 772 422 Fax: 01 932 772 433 E-mail: [email protected] ©2015 Alpha Wire. All rights reserved. Specifications subject to change. Consult Alpha Wire for latest specifications. ASIA PACIFIC Alpha Wire Silver Center | Room 1708 North Shanxi Road 1388 Shanghai | China | 200060 Tel: +86-21-61498201/61498205 Fax: +86-21-61498001 E-mail: [email protected] Lit. No. Semicon-1501 Supersedes: New