Preview only show first 10 pages with watermark. For full document please download

Seneca Instruments

   EMBED


Share

Transcript

CONVERTERS AND INTERFACES RS485 Asynchronous Converter Serial Converters USB K-LINE FUNCTION: Connect an RS-485 Network to the USB Port Speed selectable from 1.200 bps to 250 Kbps Compatible with standard USB 1.1 and 2.0 Drivers available for Windows 98, 2000 and XP Galvanic isolation @ 1500 V Spring-cage terminal block and/or DIN bus connection system (K107USB) and portable version (S107USB) TECHNICAL DATA K109PT – PT100 –converter K107USB-S107USB USB RS485 Asynchronous Converter ORDER CODES K107USB USB RS485 Asynchronous Converter (Din rail mounting) S107USB USB Accessories USB cable and drivers -included DIP Switch - Direction changing - Line termination - Transmission speed Dimensions K107USB - 6,2 x 93,1 x 102,5 mm (w x h x d) S107USB - 6,2 x 93,1 x 102,5 mm -0..+55 °C RS485 Asynchronous Converter (portable) GENERAL FEATURES Power supply Status indicators By USB port of the pc - Power - Rx - Tx Standard USB 1.1 and 2.0 Speed 1200bps…250 Kbps Operating temperature Software Compatible with Windows 98, 2000, XP IP Protection IP 20 Galvanic Isolation 1500 V between RS485 Standards Current consumption 60 mA EN50081-2 EN50082-2 EN61010-1 Humidity 30..90% a +40°C (not condensing) Approvals CE, UL-CSA (only for K107USB) USB USB SIDE RS485 SIDE USB Complete of cable: USB A and MINI USB B RS485 K107USB: Plug-in screw clamp terminal blocks, wires up to 2.5 mm2 S107USB: 5 poles connector INSTALLATION S107USB K107USB K107USB-S107USB_0712EN ► FUNCTION: Interface converter USB ↔ TTL-RS232-RS485 ► Compatible with standard USB 1.0, 1.1 and 2.0 ► Drivers available for Windows 98, 2000, XP, Vista, CE, Mac,… ► Programming software for T120, T121, K121, K120RTD and Z-PC Z I/O modules ► Galvanic isolation @ 1,5 Kvac ► Power supply (12 Vdc @ 100 mA)) available from screw terminals to supply Z-PC I/O modules ► Interface connectors: mini USB (cable included),DB9-M (RS232),TTL (cable included), 5 poles connector (RS485) For further information, please visit www.seneca.it TECHNICAL DATA ORDER CODES S117P-1 - USB ↔ TTL-RS232-RS485 Serial Converter Isolator - USB cable - TTL cable - CD with drivers and EASY software (programming software for T120, T121, K121, K120RTD and Z-PC I/O devices) OTHER DEVICES S107USB K107USB S107P Z107 - USB ↔ RS485 Serial Converter Isolator (desk) - USB ↔ RS485 Serial Converter Isolator (din rail) - RS232 ↔ RS485 Serial Converter Isolator (desk) - RS232 ↔ RS485 Serial Converter Isolator (din rail) GENERAL FEATURES Power supply By the PC (USB port) Design Portable (table version) Status indicators - Power - Transmission - Receiving Speed 300…250.000 bps Configuration By drivers (included). Other functions X or Y side terminator, X->Y or Y->X communication direction inhibition Operating temperature Galvanic Isolation 1500 Vac IP Protection IP 20 Power consumption 50 mA Standards Humidity 10..90% a +40°C (not condensing) EN61000-6 EN6100-6 EN61010-1 Approvals CE USB PORT Connection - USB: mini USB B (cable inlcuded) RS232: DB9-M TTL: RJ-10 RS485: 5 poles connector Dimensions 50 x 90 x 25 mm (w x h x d) Weight 55 g -20..+65 °C RS232-TTL PORT USB Mini USB B connector (cable included) Standard 1.0, 1.1 e 2.0 Windows 98, 98SE, ME, 2000, Server2003, XP. Windows XP 64bit. Windows Vista. Windows XP embedded. Windows CE.net 4.2 & 5.0. Mac OS 8, 9, OS-X. Linux con Kernel 2.4.20 ✔ ✔ ✔ ✔ ✔ ✔ ✔ RS232 DB9-M connector TTL RJ-10 connector (cable included) RS485 5 poles connector INSTALLATION S117P1_1010EN Z107 SERIAL CONVERTER RS232 <-> RS485/422 FOR DIN GUIDE Serial interface converter for assembly onto the DIN guide from RS232 to RS485 which are necessary in order to allow the personal computer to communicate with any external device with an RS485/422 interface, up to a maximum of 32 users and maximum velocity of 1115.200 bps. 1 2 3 4 5 6 P ow er su pply R T S state D a ta transm ission D a ta re ception Ideal for programming all of the modules of the Z-PC Series. As they have galvanic isolation, they protect the computer from possible overvoltage or short-circuits which could arise from the devices connected by means of the RS485. They can be used as converters with automatic change of direction (timed) otherwise piloted by the RTS (RS232) signal. Furthermore, they allow both HALF as well as FULL DUPLEX communication (simultaneous reception and transmission on RS485). Velocity, type of communication and change of direction system can be set quite easily by means of the dip-switch located on one side of the converters. 7 8 9 10 11 12 The LEDs located on the front panel allow for the functioning of the converter itself to be checked: the presence of power, reception and transmission of data, state of the RTS signal. As opposed to the portable S107P model, in the Z107P the connection to the serial port of the PC is provided by means of the DB9 connector located on the front panel of the instrument together with an extremely common serial 9 pin connector cable. The connection on the RS485 side is provided by means of the extractable terminal box. The connections for the RS485 interface and powering of the module are also present within the connector on the back of the instrument and allow fordirect connection to the bus of the Z-PC series by means of the appropriate support that is to be installed in the DIN guide. TECHNICAL DATA • • • • • • • • • Power supply : 19 - 40 Vcc / 19 - 28 Vca - 50/60 Hz, power consumption max. 2,5W Galvanic separation RS232 // RS485 and power supply // RS485 : 1500 Vac Interface 1 : serial RS232 on a DB9 connector on the front panel Interface 2 : serial RS485/422, extractable clamps with screw type connections Functioning method : 2 Half Duplex wires, 4 Full Duplex wires, point-point or multidrop Change of direction : automatic timing, command from RTS from the interface RS232 Communication velocity : settable between 9600, 19200, 38400, 57600, 115200 bps Connection distance : up to 1200 m For further information make reference to page 2. Refer to instructions manual for further informations SENECA IT 07.01 18 Fiber Optic RS232 / RS485 serial converter Power Supply Serial ports : Max Baud rate: Max Distance: Fiber Optic : Operating Termperature: Dimensions: 12..40 Vdc or 12..28 Vac (50-60 Hz) RS232 (DB9-F (DB9 connector), RS485 IDC 10 connector or terminal blocks 115.200 bps 2 km Multimodal (62,5/125 o 50/125 m), ST – ST connectors -30..+60 30..+60°C 17,5 x 100 x 112 mm (w x h x d) For further information, please visit www.seneca.it ORDER CODE Model Z107FO Accessories Fiber Optic RS232 / RS485 serial converter Z-PC FO Fiber Optic cable with ST/ST connectors, L=2 m Z-PC DIN Backplane connectors TECHNICAL SPECIFICATIONS GENERAL FEATURES COMMUNICATION Power Supply 12..40 Vdc, 12..28 Vac (50-60 Hz) RS232 DB9-F (COM) connector Consumption 1,2 W RS485 Status indicators Serial communication state, fiber optic state Screw terminal block, Back connectors IDC10 for DIN DB9-F (COM) Operating temperature -30..+60 °C Storage temperature -30..+85 °C Speed From 1.200 to 115.200 bps Delay Humidity 30..90% not condensing 160 – 240 ms (@ 9.600 bps) 145 – 155 ms (@ 115.200 bps) Dimensions 17,5 x 100 x 112 mm (w x h x d) Fiber optic Multimodal(62,5/125 o 50/125 m) ST/ST connectors Weight 140 g Enclosure PBT, black Configuration DIP-switch (baud rate, parity, serial port, bit stop, termination) Conformity CE, EN 61000-6-4, EN 64000-6-2, EN 61010-1, EN 60742 CONNECTIONS Power supply (IDC10) DB9 PC connector Functional diagram Power Supply (Terminal block) Z107FO RS232 port –DB9-F connector RS485 port – Terminal block Connection RS485 remote nodes depending on the baud rate Application example Z107FO_0902EN Fiber Optic CAN bus converter Power Supply CAN interface Fiber Optic Operating Temperature Dimensions Typical use 12..40 Vdc or 12..28 Vac (50-60 (50 Hz) CANBUS 2.0 Protocol, max speed1 Mbps, IDC 10 connector Multimodal (62,5/125 o 50/125 m), ST – ST connectors -30..+60°C 17,5 x 100 x 112 mm (w x h x d) Isolator, repeater and coupler for CAN buses For further information, please visit www.seneca.it ORDER CODE Model ZC-107FO Accessories Fiber Optic CAN serial converter Z-PC-DINAL2-17.5 Terminal block for power / bus + 2 slot Z-PC-DIN2-17.5 2 slot block 17.5 mm Z-PC-DIN8-17.5 8 slot block 17.5 mm TECHNICAL SPECIFICATION GENERAL FEATURES FIBER OPTIC Power Supply 12..40 Vdc, 12..28 Vac (50-60 Hz) Type Multimodal(62,5/125 o 50/125 m) Power consumption 1,2 W Connectors ST / ST Frontal connectors Status indication State, communication, functioning Delay message 300 s Galvanic Isolation 500 Vac input // power supply -30..+60 °C Max distance 2 km Operating temperature Storage Temperature -30..+85 °C Humidity 30..90% non condensing Dimensions 17,5 x 100 x 112 mm(w x h x d) Weight 140 g Housing PBT, black color Mounting DIN 46277 guide Protocol CANBUS 2.0 Configuration Via DIP-switches (baud rate, parity, serial port, bit stop, termination) Max speed 1 Mbps Conformity CE, EN 61000-6-4, EN 64000-6-2, EN 61010-1, EN 60742 CAN INTERFACE Terminals Screws, removables , 3 way, 5,08 mm Connectors IDC10 back connectors (Din guide) CONNECTIONS, INSTALLATION, LAYOUT Power supply by IDC10 back connector Application example Application example Backplane for din guide CAN port Power through terminals CAN line Mounting on DIN guide Layout ZC-107FO_0912EN