Transcript
CONVERTERS AND INTERFACES
RS485 Asynchronous Converter
Serial Converters
USB
K-LINE
FUNCTION: Connect an RS-485 Network to the USB Port Speed selectable from 1.200 bps to 250 Kbps Compatible with standard USB 1.1 and 2.0 Drivers available for Windows 98, 2000 and XP Galvanic isolation @ 1500 V Spring-cage terminal block and/or DIN bus connection system (K107USB) and portable version (S107USB)
TECHNICAL DATA K109PT – PT100 –converter K107USB-S107USB USB RS485 Asynchronous Converter ORDER CODES K107USB
USB RS485 Asynchronous Converter (Din rail mounting)
S107USB
USB
Accessories
USB cable and drivers -included
DIP Switch
- Direction changing - Line termination - Transmission speed
Dimensions
K107USB - 6,2 x 93,1 x 102,5 mm (w x h x d) S107USB - 6,2 x 93,1 x 102,5 mm -0..+55 °C
RS485 Asynchronous Converter (portable)
GENERAL FEATURES Power supply Status indicators
By USB port of the pc - Power - Rx - Tx
Standard
USB 1.1 and 2.0
Speed
1200bps…250 Kbps
Operating temperature
Software
Compatible with Windows 98, 2000, XP
IP Protection
IP 20
Galvanic Isolation
1500 V between RS485
Standards
Current consumption
60 mA
EN50081-2 EN50082-2 EN61010-1
Humidity
30..90% a +40°C (not condensing)
Approvals
CE, UL-CSA (only for K107USB)
USB
USB SIDE
RS485 SIDE USB Complete of cable: USB A and MINI USB B
RS485 K107USB: Plug-in screw clamp terminal blocks, wires up to 2.5 mm2 S107USB: 5 poles connector
INSTALLATION S107USB
K107USB
K107USB-S107USB_0712EN
► FUNCTION: Interface converter USB ↔ TTL-RS232-RS485 ► Compatible with standard USB 1.0, 1.1 and 2.0 ► Drivers available for Windows 98, 2000, XP, Vista, CE, Mac,… ► Programming software for T120, T121, K121, K120RTD and Z-PC Z I/O modules ► Galvanic isolation @ 1,5 Kvac ► Power supply (12 Vdc @ 100 mA)) available from screw terminals to supply Z-PC I/O modules ► Interface connectors: mini USB (cable included),DB9-M (RS232),TTL (cable included), 5 poles connector (RS485)
For further information, please visit www.seneca.it
TECHNICAL DATA ORDER CODES S117P-1
- USB ↔ TTL-RS232-RS485 Serial Converter Isolator - USB cable - TTL cable - CD with drivers and EASY software (programming software for T120, T121, K121, K120RTD and Z-PC I/O devices)
OTHER DEVICES S107USB K107USB S107P Z107
- USB ↔ RS485 Serial Converter Isolator (desk) - USB ↔ RS485 Serial Converter Isolator (din rail) - RS232 ↔ RS485 Serial Converter Isolator (desk) - RS232 ↔ RS485 Serial Converter Isolator (din rail)
GENERAL FEATURES Power supply
By the PC (USB port)
Design
Portable (table version)
Status indicators
- Power - Transmission - Receiving
Speed
300…250.000 bps
Configuration
By drivers (included).
Other functions
X or Y side terminator, X->Y or Y->X communication direction inhibition
Operating temperature
Galvanic Isolation
1500 Vac
IP Protection
IP 20
Power consumption
50 mA
Standards
Humidity
10..90% a +40°C (not condensing)
EN61000-6 EN6100-6 EN61010-1
Approvals
CE
USB PORT
Connection
-
USB: mini USB B (cable inlcuded) RS232: DB9-M TTL: RJ-10 RS485: 5 poles connector
Dimensions
50 x 90 x 25 mm (w x h x d)
Weight
55 g -20..+65 °C
RS232-TTL PORT USB Mini USB B connector (cable included) Standard 1.0, 1.1 e 2.0 Windows 98, 98SE, ME, 2000, Server2003, XP. Windows XP 64bit. Windows Vista. Windows XP embedded. Windows CE.net 4.2 & 5.0. Mac OS 8, 9, OS-X. Linux con Kernel 2.4.20
✔ ✔ ✔ ✔ ✔ ✔ ✔
RS232 DB9-M connector TTL RJ-10 connector (cable included) RS485 5 poles connector
INSTALLATION
S117P1_1010EN
Z107 SERIAL CONVERTER RS232 <-> RS485/422 FOR DIN GUIDE Serial interface converter for assembly onto the DIN guide from RS232 to RS485 which are necessary in order to allow the personal computer to communicate with any external device with an RS485/422 interface, up to a maximum of 32 users and maximum velocity of 1115.200 bps.
1 2 3 4 5 6 P ow er su pply R T S state D a ta transm ission D a ta re ception
Ideal for programming all of the modules of the Z-PC Series. As they have galvanic isolation, they protect the computer from possible overvoltage or short-circuits which could arise from the devices connected by means of the RS485. They can be used as converters with automatic change of direction (timed) otherwise piloted by the RTS (RS232) signal. Furthermore, they allow both HALF as well as FULL DUPLEX communication (simultaneous reception and transmission on RS485). Velocity, type of communication and change of direction system can be set quite easily by means of the dip-switch located on one side of the converters.
7 8 9 10 11 12
The LEDs located on the front panel allow for the functioning of the converter itself to be checked: the presence of power, reception and transmission of data, state of the RTS signal. As opposed to the portable S107P model, in the Z107P the connection to the serial port of the PC is provided by means of the DB9 connector located on the front panel of the instrument together with an extremely common serial 9 pin connector cable. The connection on the RS485 side is provided by means of the extractable terminal box. The connections for the RS485 interface and powering of the module are also present within the connector on the back of the instrument and allow fordirect connection to the bus of the Z-PC series by means of the appropriate support that is to be installed in the DIN guide.
TECHNICAL DATA • • • • • • • • •
Power supply : 19 - 40 Vcc / 19 - 28 Vca - 50/60 Hz, power consumption max. 2,5W Galvanic separation RS232 // RS485 and power supply // RS485 : 1500 Vac Interface 1 : serial RS232 on a DB9 connector on the front panel Interface 2 : serial RS485/422, extractable clamps with screw type connections Functioning method : 2 Half Duplex wires, 4 Full Duplex wires, point-point or multidrop Change of direction : automatic timing, command from RTS from the interface RS232 Communication velocity : settable between 9600, 19200, 38400, 57600, 115200 bps Connection distance : up to 1200 m For further information make reference to page 2.
Refer to instructions manual for further informations
SENECA
IT 07.01
18
Fiber Optic
RS232 / RS485 serial converter
Power Supply Serial ports : Max Baud rate: Max Distance: Fiber Optic : Operating Termperature: Dimensions:
12..40 Vdc or 12..28 Vac (50-60 Hz) RS232 (DB9-F (DB9 connector), RS485 IDC 10 connector or terminal blocks 115.200 bps 2 km Multimodal (62,5/125 o 50/125 m), ST – ST connectors -30..+60 30..+60°C 17,5 x 100 x 112 mm (w x h x d)
For further information, please visit www.seneca.it
ORDER CODE Model
Z107FO
Accessories
Fiber Optic
RS232 / RS485 serial converter
Z-PC FO Fiber Optic cable with ST/ST connectors, L=2 m Z-PC DIN Backplane connectors
TECHNICAL SPECIFICATIONS GENERAL FEATURES
COMMUNICATION
Power Supply
12..40 Vdc, 12..28 Vac (50-60 Hz)
RS232
DB9-F (COM) connector
Consumption
1,2 W
RS485
Status indicators
Serial communication state, fiber optic state
Screw terminal block, Back connectors IDC10 for DIN DB9-F (COM)
Operating temperature
-30..+60 °C
Storage temperature
-30..+85 °C
Speed
From 1.200 to 115.200 bps
Delay
Humidity
30..90% not condensing
160 – 240 ms (@ 9.600 bps) 145 – 155 ms (@ 115.200 bps)
Dimensions
17,5 x 100 x 112 mm (w x h x d)
Fiber optic
Multimodal(62,5/125 o 50/125 m) ST/ST connectors
Weight
140 g
Enclosure
PBT, black
Configuration
DIP-switch (baud rate, parity, serial port, bit stop, termination)
Conformity
CE, EN 61000-6-4, EN 64000-6-2, EN 61010-1, EN 60742
CONNECTIONS Power supply (IDC10)
DB9 PC connector
Functional diagram
Power Supply (Terminal block)
Z107FO
RS232 port –DB9-F connector
RS485 port – Terminal block
Connection RS485 remote nodes depending on the baud rate
Application example
Z107FO_0902EN
Fiber Optic
CAN bus converter
Power Supply CAN interface Fiber Optic Operating Temperature Dimensions Typical use
12..40 Vdc or 12..28 Vac (50-60 (50 Hz) CANBUS 2.0 Protocol, max speed1 Mbps, IDC 10 connector Multimodal (62,5/125 o 50/125 m), ST – ST connectors -30..+60°C 17,5 x 100 x 112 mm (w x h x d) Isolator, repeater and coupler for CAN buses
For further information, please visit www.seneca.it
ORDER CODE Model
ZC-107FO
Accessories
Fiber Optic
CAN serial converter
Z-PC-DINAL2-17.5 Terminal block for power / bus + 2 slot Z-PC-DIN2-17.5 2 slot block 17.5 mm Z-PC-DIN8-17.5 8 slot block 17.5 mm
TECHNICAL SPECIFICATION GENERAL FEATURES
FIBER OPTIC
Power Supply
12..40 Vdc, 12..28 Vac (50-60 Hz)
Type
Multimodal(62,5/125 o 50/125 m)
Power consumption
1,2 W
Connectors
ST / ST Frontal connectors
Status indication
State, communication, functioning
Delay message
300 s
Galvanic Isolation
500 Vac input // power supply -30..+60 °C
Max distance
2 km
Operating temperature Storage Temperature
-30..+85 °C
Humidity
30..90% non condensing
Dimensions
17,5 x 100 x 112 mm(w x h x d)
Weight
140 g
Housing
PBT, black color
Mounting
DIN 46277 guide
Protocol
CANBUS 2.0
Configuration
Via DIP-switches (baud rate, parity, serial port, bit stop, termination)
Max speed
1 Mbps
Conformity
CE, EN 61000-6-4, EN 64000-6-2, EN 61010-1, EN 60742
CAN INTERFACE
Terminals
Screws, removables , 3 way, 5,08 mm
Connectors
IDC10 back connectors (Din guide)
CONNECTIONS, INSTALLATION, LAYOUT Power supply by IDC10 back connector
Application example
Application example
Backplane for din guide
CAN port
Power through terminals
CAN line
Mounting on DIN guide
Layout
ZC-107FO_0912EN