Preview only show first 10 pages with watermark. For full document please download

Sensaphone 800 Technical Specifications

   EMBED


Share

Transcript

Sensaphone 400 & 800 Technical Specifications Input Zones Number of Zones: 400 - 4, 800 - 8 Power Supply Zone Connector: terminal block Power Supply: 120VAC/9VDC 60Hz 6W wall plug-in transformer w/6’ cord. Zone Types: Power Consumption: 1.5 Watts N.O./N.C. contact, 2.8K Thermistor -20° to 150ºF | -30º to 65ºC Power Protection: Metal Oxide Varistor Zone Characteristics: 5.11K to 2.85V (Short circuit current: 1mA max.) A/D Converter Resolution: 10 bits ±2 LSB Zone Protection: 5.5VDC Metal Oxide Varistor with fast acting diode clamps. Relay output Rated for 1A 30VAC/1A 30VDC maximum. LED Indicators System On, Phone In Use, Alarm, Battery Ok. Microphone Internal Electret Condenser: For listening in to on-site sounds and detecting high sound levels. Battery Backup: Six size-C alkaline batteries (not included), providing up to 24 hours of backup time. Environmental Operating Temperature: 32° to 122°F | 0° to 50°C Operating Humidity: 0–90% RH non-condensing Storage Temperature: 32° to 140°F | 0° to 60°C Physical Dimensions: 2.1 x 7.8 x 8.8”d | 5 x 20 x 22mm Weight: 8 lbs. | 3.6kg Enclosure: Indoor rated ABS Plastic & Polycarbonate w/clear window door Phone Interface Line RJ11 Jack: For connection to a two-wire analog telephone line. (6’ modular cord included) Extension RJ11 Jack w/ Line Seizure: For connecting other devices on the same telephone line, devices connected to this jack are disconnected in the event that the 400 must dial out for an alarm. Phone Line Protection: Metal Oxide Varistor & self-resetting fuse 901 Tryens Road • Aston, PA 19014 • PH: 877-373-2700 • F: 610-558-0222 • www.sensaphone.com