Transcript
V
Series 230/230VAC
Standard & LB, Universal Tower/Rack Mount 1000VA, 1500VA, 2000VA & 3000VA
On-line, Single Phase, Double Conversion UPS The UniStar® V features a field-proven Digital Signal Processor (DSP) achieving high reliability, while providing protection from electrical power disturbances to the connected load. The convertible tower/ rack design offers maximum flexibility, enabling UPS integration into a wide variety of environments. Industry-leading functionality is standard and includes hot swappable battery, powerful internal charger, emergency shut-down and programmable receptacles. The UniStar® V is an ideal power protection solution for servers, networks, telecommunications, industrial equipment, and manufacturing processes. LB Models are for those critical applications that require extended battery backup times.
True Double-Conversion On-Line UPS A true double conversion UPS will pro-vide clean, high level quality power to fully protect mission-critical devices such as sensitive networks, small computer center servers, telecom applications, as well as for industrial applications.
n
Output Power Factor 0.9 UniStar Series V is a high-density UPS with an output power factor 0.9 to provide higher performance and efficiency to critical applications.
n
User-Friendly and Easy-Shift LCD Display The front panel digital display can be easily shifted through LCD setting to suit the installation format, Tower or Rack mount
n
Rack/Tower Design The Series V is designed in a true universal-mount case. It can be easily installed as a free-standing tower or in a 19-inch rackmount configuration.
n
Programmable Power Management Outlets With programmable power management outlets, users can easily and independently control load segments. During power failure, this feature enables users to extend battery time to mission-critical devices by shutting down the non-critical devices.
n
50/60 Hz Frequency Converter Mode Lock output frequency at 50Hz or 60Hz to suit power sensitive equipment.
n
ECO and Advanced ECO Mode for Energy Saving It allows the UPS to operate in high efficiency up to 97% in energy-saving ECO mode. In this operation mode, load is supplied by the mains. In the event of a mains failure, the inverter takes over the load and provides supply continuity to the connected systems. The Series V offers advanced ECO mode to allow UPS to operate at higher efficiency up to 98%.
n
Emergency Power Off Function (EPO)
This feature can secure the personnel and equipment in case of fires or other emergencies.
n
Hot-Swappable Battery Design Ensures clean and uninterruptible power to protected equipment during battery replacement.
n
www.stacoenergy.com
Your Tailored Power Solutions ProviderTM
On-Line, Single Phase UPS System The UniStar® V represents the latest in single-phase technology at an affordable price. Its true on-line performance provides a constant clean, steady sine wave safeguarding the most sensitive equipment. Double Conversion
supplied to the loads while in bypass
The UPS provides clean AC power with
mode.
voltage and frequency independent from the utility. On-line technology completely regenerates utility power to correct electrical disturbances in the
Applications Broadcast n Processing Manufacturing (food/beverage, pharmaceutical, plastics, packaging) n Water and Waste Water Treatment n Hospitals/Medical n Education/Research Laboratories n
User Controls An easy-to-read user-friendly LCD display provides real-time indication of all major
mains.
system parameters and status, including
High-Efficiency and Protection
signals for easy service.
load level, battery remaining, and fault
PWM sine-wave topology yields excellent overall performance. The high crest factor of the inverter handles all high in-rush current loads without the need to upgrade the power rating.
Digital signal processing (DSP) also provides the UPS with powerful communication capability, which enhances Wide frequency and voltage windows
the flexibility for easy remote control and
of 40-70Hz and 55-150Vac (for 120Vac
monitoring.
input), or 110-300Vac (for 230Vac input), are provided, which help to extend the life of
Features
the battery.
DC-start function ensures the start-up of
Near unity input power factor meets
UPS even during power outages.
today’s industry standard for energy savings and efficiency with low current harmonic pollution to the utility.
Programmable receptacles offer the capability to load shed during any power interruption, while in battery power mode
To protect the unit from overloading, the
or during overload condition, via the use of
UPS will automatically switch to by-
special communication software provided,
pass mode in 30 seconds if loading is at
thus reserving backup power for
105%~120% of rated capacity.
priority loads.
It will automatically switch back to inverter mode once overload condition ceases. Selectable bypass input voltage tolerance (low/high sensitivity) prevents under or over voltage being
Emergency shutdown control through EPO allows users to shutdown the UPS completely in an emergency to ensure a safe operating environment. Staco Energy Products Co.
Three Year Warranty
Communication software allows not
are shown in the table below. Back-
only the control of the UPS and its smooth
up time is for the battery pack used
shutdown when utility fails, but also allows
with the UPS internal batteries.
the user to:
Battery packs are external and hot
A full Three Year parts with depot repair or replacement warranty is standard.
n Completely test the major operating functions of the UPS
swappable.
Battery:
n Communicate via SNMP/Web/ Network adapter
Bypass Switch—manually operated,
n Access UPS functions via the Web
of power to the critical load in the
n Alert users via SMS messages against specific events
event of unexpected or scheduled main-
Optional Make-Before-Break external—ensures continuous supply
tenance.
Custom options slot allows further flexibility in network configuration.
Electronics:
A full One Year Warranty on the Battery System ensures that your batteries are protected from system failure now and in the future. (Warranty provided by battery manufacturer.) Extended warranties, customized service plans and preventative maintenance are also available. Please refer to our warranty statement for complete details.
An internal WEB/SNMP card, USB card, and True Relay card provide isolated contacts for industrial and remote alarm panel application. User-friendly Plug-and-Play design
Optional Maintenance Bypass
allows hassle-free installation. All units up
Model Number
Rating
to 3kVA are supplied with input cables and
USC-MBPDU-12
1000VA / 2000VA
USC-MBPDU-32
3000VA
output receptacles as standard. Innovative battery management cir-
Input Connection Attached 6' Cord with IEC C14 Attached 6' Cord with IEC C20
Output Receptacles (8) IEC C13 (6) IEC C13 & (1) IEC C18
Dimensions: 3.50" H x 17.30"W x 3.00"D (2U) / [88.9 x 439.4 x 76.2]
cuit analyzes battery discharging status to adjust battery cut-off point and extend the batteries’ life span. Internal maintenance-free sealed VRLA batteries minimizes the need for frequent after-sales service. The hot swappable battery feature allows users to replace the batteries without the hazard of electric shock, while the UPS supplies power continuously to critical load applications. Built-in Charger provides ability to re-charge internal battery to approximately 90% in four hours. Matching battery cabinets are available to extend the UPS runtime easily to
Standard Run Time Models UPS On-line, Double-Conversion .9pf – LCD Panel, USB and RS-232 Standard Internal VA/ Output Model Number Battery Input Cord Watts Connections (Minutes)
*Dimensions H" x W" x D" / [mm]
Voltage: 230/230 VAC – 50/60 Hz – 1000VA, 1500VA, 2000VA & 3000VA CE, 3000VA CE/UL1778/cUL (10A) x 17.24" x 16.44" (2U) 1000VA/900W 2.7 (8) IEC60320-C13 3.39" [86.2 x 438.0 x 417.5] IEC320-C14 (10A) x 17.24" x 20.38" (2U) SCV-15002 1500VA/1350W 2.7 (8) IEC60320-C13 3.39" [86.2 x 438.0 x 517.5] IEC320-C14 (16A) 3.39" x 17.24" x 20.38" (2U) SCV-20002 2000VA/1800W 2.7 (8) IEC60320-C13 [86.2 x 438.0 x 517.5] IEC320-C20 (16A) x 17.24" x 25.10" (2U) SCV-30002 3000VA/2700W 2.7 (6) IEC60320-C13 3.39" [86.2 x 438.0 x 637.5] IEC320-C20 Voltage: 230/230 VAC – 50/60 Hz – 1000VA, 1500VA, 2000VA & 3000VA-LB CE, 3000VA CE/UL1778/cUL (10A) x 17.24" x 16.44" (2U) SCV-10002-LB 1000VA/900W 0 (8) IEC60320-C13 3.39" [86.2 x 438.0 x 417.5] IEC320-C14 (10A) x 17.24" x 20.38" (2U) SCV-15002-LB 1500VA/1350W 0 (8) IEC60320-C13 3.39" [86.2 x 438.0 x 517.5] IEC320-C14 (16A) 3.39" x 17.24" x 20.38" (2U) SCV-20002-LB 2000VA/1800W 0 (8) IEC60320-C13 [86.2 x 438.0 x 517.5] IEC320-C20 (16A) (6) IEC60320-C13 3.39" x 17.24" x 25.10" (2U) SCV-30002-LB 3000VA/2700W 0 [86.2 x 438.0 x 637.5] IEC320-C20 (1) IEC60320-C20
SCV-10002
*Wt. lbs. / (kg) 29 / (13) 42 / (19) 47 / (21) 65 / (29) 20 / (9) 26 / (12) 27 / (12) 33 / (15)
Standard SCV-X0002: maximum (1) External Battery Pack (SCV-BAT-1K, SCV-BAT-1.5K, SCV-BAT-2K or SCV-BAT-3K) LB Models: maximum (5)External Battery Pack (SCV-BAT-1K, SCV-BAT-1.5K, SCV-BAT-2K or SCV-BAT-3K)
several hours. Optional extended runtime
*Always reference Spec Control Drawing (SCD) for the most current & accurate dimensions and weights
capability by simply connecting additional battery packs. Just plug in the battery connectors between the UPS and battery packs without the requirement for additional chargers. Extended run time battery packs are available for all models. Size, capacity, and estimated run times UniStar® V Rack/Universal
www.stacoenergy.com
Specification for 230/230VAC Model (SCV)
10002
Capacity VA/ Watts INPUT Rated Volts
10002-LB
15002
1000 VA / 900 W
20002
20002-LB
2000 VA / 1800 W
30002
30002-LB
3000 VA / 2700 W
220-240 VAC 160 VAC/140 VAC/120 VAC/110 VAC ± 5 % (based on load percentage 100%-80% / 80%-70% / 70%-60% / 60%-0) 170 VAC / 150 VAC / 130 VAC / 120 VAC ± 5 %
Low Transfer Capacity
15002-LB
1500 VA / 1350 W
Re-Transfer High Transfer
300 VAC ± 5 %
Re-Transfer
290 VAC ± 5 %
Frequency Range
40 Hz ~ 70 Hz
Power Factor
>0.99 @nominal voltage
OUTPUT Output Voltage
200/208/220/230/240 VAC
AC Voltage Regulation
± 1%
Frequency Range
47 ~ 53 Hz or 57 ~ 63 Hz (Synchronized Range)
Frequency Range
50Hz ± 0.5% or 60Hz ± 0.5% (Bat. Mode)
Current Crest Ratio (CF) Harmonic Distortion (THDU) Transfer AC to DC Inv. to Time Bypass Waveform (Battery Mode) EFFICIENCY
5:1 (max.) < 2% THD (Linear load) 6% max (battery mode before shutdown) Zero 4 ms (Typical) Pure Sinewave
AC Mode
87%
88%
88%
Battery Mode
85%
86%
85%
BATTERY (NON-LB MODELS) Battery Type
(2) 12V/9Ah
No Internal
Typical Recharge Time
(3) 12V/9Ah
No Internal
(4) 12V/9Ah
No Internal
(6) 12V/9Ah
No Internal
1 Amp
6 Amp
4 hours recover to 90% capacity (for Non- LB models only)
Charging Current (max.)
1 Amp
Charging Voltage
6 Amp
27.4 VDC ± 1%
1 Amp
6 Amp
41.1 VDC ± 1%
1 Amp
6 Amp
54.7 VDC ± 1%
82.1VDC ± 1%
LCD DISPLAY Status
Load level 0-25%, 26-50%, 51-75% and 76-100%, Low Battery and Battery Good, Programmable Management Outlets working, UPS On-Line, UPS in Frequency Converter Mode, UPS On Bypass, Alarm Disabled Indicator and Battery Charger Working.
Readings
Input Voltage and Frequency, Output Voltage and Frequency, Battery Backup Time (hours/minutes), Fault Indicator, Battery Voltage, Overload, and/ or UPS Output is short circuited.
Control/Select Buttons
Off/Enter - Turn UPS Off, Switch LCD Message, Mode Settings, Navigation Key, On/Mute + Select Button to switch to Bypass Mode.
AUDIBLE & VISUAL ALARMS Warning Indicators
Low battery, Overload, Battery Not Connected, Overcharge, Site Wiring Fault, EPO Enabled, Over Temperature, Charger Failure, Battery Fault, Bypass Out of Range and Bypass Frequency Unstable
**PHYSICAL WEIGHT & DIMENSIONS H" x W" x D" / [mm] 3.39" x 17.24" x 16.44" (2U) Rack Mount [86.2 x 438.0 x 417.5] 17.24" x 3.39" x 16.44" (2U) Tower [438.0 x 86.2 x 417.5] Net Weight lbs. / (kg) 29 / (13) 20 / (9)
3.39" x 17.24" x 20.38" (2U) [86.2 x 438.0 x 517.5] 17.24" x 3.39" x 20.38" (2U) [438.0 x 86.2 x 517.5] 42 / (19) 26 / (12)
3.39" x 17.24" x 20.38" (2U) [86.2 x 438.0 x 517.5] 17.24" x 3.39" x 20.38" (2U) [438.0 x 86.2 x 517.5] 47 / (21) 27 / (12)
3.39" x 17.24" x 25.10" (2U) [86.2 x 438.0 x 637.5] 17.24" x 3.39" x 25.10" (2U) [438.0 x 86.2 x 637.5] 65 / (29) 33 / (15)
ENVIRONMENT (Electronics) Operating
32°F (0°C) to 104°F (40°C)
Humidity
20-90 % RH (non-condensing)
Storage
-13°F (-25°C) to 104°F (40°C) BATTERIES (REFRESH Charge @ 3 months)
Noise Level
Less than 50dBA @ 1 Meter
MANAGEMENT / COMMUNICATION Smart RS-232/USB Optional SNMP
Supports Windows 2000/2003/XP/Vista/2008/7, Linux, Unix, and MAC Power management from SNMP manager and web browser
Optional MODBUS Card Optional AS400 Card
Communications from MODBUS With DB9 or 9 Pin Connector
AGENCY UL1778/CE/cUL CE UL1778/CE/cUL Listing * Derate capacity to 80% when the output voltage is adjusted to 200VAC/208VAC. **Always reference Spec Control Drawing (SCD) for the most current & accurate dimensions and weights
CE
UL1778/CE/cUL
CE
UL1778/CE/cUL
UL1778/CE/cUL
The UniStar® V Series Battery Run Time Charts Standard External Battery Run Time Chart - Minutes Used with UniStar V Series, 230VAC, Universal Tower/Rack 1000VA, 1500VA, 2000VA & 3000VA
I000VA
Internal SCV-BAT-1K
0 1
# Strings Internal / External 1/0 1/2
I500VA
Internal SCV-BAT-1.5K
0 1
1/0 1/2
24 92
10 42
5 26
2 18
3.39" x 17.24" x 20.97" (2U) [86.2 x 438.0 x 532.7]
55 / (25)
2000VA Internal SCV-BAT-2K
0 1
1/0 1/2
24 92
10 42
5 26
2 18
3.39" x 17.24" x 20.97" (2U) [86.2 x 438.0 x 532.7]
64 / (29)
3000VA Internal SCV-BAT-3K
0 1
1/0 1/2
24 92
10 42
5 26
2 18
3.39" x 17.24" x 25.70" (2U) [86.2 x 438.0 x 652.7]
91 / (41)
UPS Rating
Part Number
Quantity Cabinets
25% Load
50% Load
75% Load
100% Load
*Dimensions H" x W" x D" / [mm]
*Wt. lbs. / (kg)
24 92
10 42
5 26
2 18
3.39" x 17.24" x 17.04" (2U) [86.2 x 438.0 x 432.7]
38 / (17)
Note: 1. ONLY (1) Standard Battery Pack can be used on the SCV-X0002 Models without effecting recharge time. If (2) battery packs are used the recharge will take twice the time. 2. If longer run times are needed or future expansion is planned the LB Model is recommended. 3. Run times included total of internal and external battery strings. *Always reference Spec Control Drawing (SCD) for the most current & accurate dimensions and weights
Standard External Battery Run Time Chart - Minutes Used with UniStar V, 230VAC, LB Models, Universal Rack/Tower 1000VA, 1500VA, 2000VA & 3000VA 25% 50% 75% Quantity 100% *Dimensions UPS Rating Part Number Load Load Cabinets # Strings Load Load H" x W" x D" / [mm] 1000VA
1500VA
2000VA
3000VA
Internal SCV-BAT-1K
Internal SCV-BAT-1.5K
Internal SCV-BAT-2K
Internal SCV-BAT-3K
0 1 2 3 4 5
0 2 4 6 8 10
0 57 130 209 292 380
0 25 60 98 137 178
0 15 38 61 87 113
0 10 26 43 61 80
0 1 2 3 4 5
0 2 4 6 8 10
0 57 130 209 292 380
0 25 60 98 137 178
0 15 38 61 87 113
0 10 26 43 61 80
0 1 2 3 4 5
0 2 4 6 8 10
0 57 130 209 292 380
0 25 60 98 137 178
0 15 38 61 87 113
0 10 26 43 61 80
0 2 4 6 8 10
0 57 130 209 292 380
0 25 60 98 137 178
0 15 38 61 87 113
0 10 26 43 61 80
0 1 2 3 4 5 Note: Weights include the total of all cabinets
*Wt. lbs. / (kg)
3.39" x 17.24" x 17.04" (2U) [86.2 x 438.0 x 432.7]
3.39" x 17.24" x 20.97" (2U) [86.2 x 438.0 x 532.7]
3.39" x 17.24" x 20.97" (2U) [86.2 x 438.0 x 532.7]
3.39" x 17.24" x 25.70" (2U) [86.2 x 438.0 x 652.7]
38 / (17) 76 / (34) 114 / (51) 152 / (68) 190 / (85) 55 / (25) 110 / (50) 165 / (75) 220 / (100) 275 / (125) 64 / (29) 128 / (58) 192 / (87) 256 / (116) 320 / (145) 91 / (41) 182 / (82) 273 / (123) 364 / (164) 455 / (205)
Rack Model Shown
n Tower/Rack Mount Convertible Design n Compact and Lightweight n Advanced Digital Control Technology n Wide Input Voltage and Frequency Ranges n Hot Swappable Battery n Extended Run Time Capability n Optional Make-Before-Break
*Always reference Spec Control Drawing (SCD) for the most current & accurate dimensions and weights
UniStar® V Rack/Universal
www.stacoenergy.com
Maintenance Bypass
The UniStar® V Series Battery Run Time Charts (Continued) External Extended Battery Pack Run Time Chart - Minutes For UniStar V Series, 230VAC, LB Models Universal Tower/Rack Mount Models, 1000VA, 1500VA, 2000VA & 3000VA Quantity Cabinets
# Strings
25% Load
50% Load
75% Load
100% Load
(2) HR1251W Batteries per string SCV-BAT-51-1K-1 1000VA SCV-BAT-51-1K-2 SCV-BAT-51-1K-3 SCV-BAT-51-1K-4 SCV-BAT-51-1K-5 SCV-BAT-51-1K-6 SCV-BAT-51-1K-7 SCV-BAT-51-1K-8
1 1 1 1 1 1 1 1
1 2 3 4 5 6 7 8
42 105 174 246 318 390 460 529
18 45 77 111 147 185 222 260
11 27 46 68 90 114 138 163
(2) HR1290W Batteries per string SCV-BAT-90-1K-1 1000VA SCV-BAT-90-1K-2 SCV-BAT-90-1K-3 SCV-BAT-90-1K-4 SCV-BAT-90-1K-5
1 1 1 1 1
1 2 3 4 5
85 194 310 428 548
38 90 147 205 266
(2) HR12150W Batteries per string SCV-BAT-150-1K-1 1000VA SCV-BAT-150-1K-2 SCV-BAT-150-1K-3
1 1 1
1 2 3
166 355 554
(3) HR1251W Batteries per string SCV-BAT-51-1.5K-1 1500VA SCV-BAT-51-1.5K-2 SCV-BAT-51-1.5K-3 SCV-BAT-51-1.5K-4
1 1 1 1
1 2 3 4
(3) HR1290W Batteries per string SCV-BAT-90-1.5K-1 1500VA SCV-BAT-90-1.5K-2
1 1
1 2
UPS Rating
Part Number
*Dimensions H" x W" x D" / [mm]
*Wt. lbs. / (kg)
7 18 31 46 62 78 96 114
8.72" x 19.00" x 22.94"(5U) [221.5 x 482.6 x 582.5]
55 / (25) 71 / (32) 88 / (40) 104 / (47) 120 / (54) 136 / (62) 152 / (69) 169 / (77)
23 56 92 130 170
15 39 64 92 120
8.72" x 19.00" x 22.94"(5U) [221.5 x 482.6 x 582.5]
69 / (31) 100 / (45) 130 / (59) 160 / (73) 190 / (86)
81 175 273
50 114 179
34 82 130
8.72" x 19.00" x 22.94"(5U) [221.5 x 482.6 x 582.5]
90 / (41) 141 / (64) 193 / (88)
42 105 174 246
18 45 77 111
11 27 46 68
7 18 31 46
8.72" x 19.00" x 22.94"(5U) [221.5 x 482.6 x 582.5]
63 / (28) 87 / (39) 111 / (50) 135 / (61)
85 194
38 90
23 56
15 39
SCV-BAT-90-1.5K-2
2
4
428
205
130
92
SCV-BAT-90-1.5K-2
3
6
670
327
210
149
1
1
166
81
50
34
8.72" x 19.00" x 22.94"(5U) [221.5 x 482.6 x 582.5] 17.44" x 19.00" x 22.94" (10U) [443.0 x 482.6 x 582.5] 26.16" x 19.00" x 22.94" (15U) [664.5 x 482.6 x 582.5]
85 / (39) 130 / (59) 260 / (118) 390 / (177)
(3) HR12150W Batteries per string 1500VA
SCV-BAT-150-1.5K-1 SCV-BAT-150-1.5K-1
2
2
355
175
114
82
SCV-BAT-150-1.5K-1
3
3
554
273
179
130
(4) HR1251W Batteries per string SCV-BAT-51-2K-1 2000VA SCV-BAT-51-2K-2 SCV-BAT-51-2K-3 SCV-BAT-51-2K-4
1 1 1 1
1 2 3 4
42 105 174 246
18 45 77 111
11 27 46 68
7 18 31 46
(4) HR1290 Batteries per string SCV-BAT-90-2K-1 2000VA SCV-BAT-90-2K-2
1 1
1 2
85 194
38 90
23 56
15 39
SCV-BAT-90-2K-2
2
4
428
205
130
92
SCV-BAT-90-2K-2
3
6
670
327
210
149
SCV-BAT-150-2K-1
1
1
166
81
50
34
SCV-BAT-150-2K-1
2
2
355
175
114
82
SCV-BAT-150-2K-1
3
3
554
273
179
130
(6) HR1251W Batteries per string SCV-BAT-51-3K-1 3000VA SCV-BAT-51-3K-2
1 1
1 2
42 105
18 45
11 27
7 18
SCV-BAT-51-3K-2
2
4
246
111
68
46
SCV-BAT-51-3K-2
3
6
390
185
114
78
SCV-BAT-150-3K-1
1
1
166
81
50
34
SCV-BAT-150-3K-1
2
2
355
175
114
82
SCV-BAT-150-3K-1
3
3
554
273
179
130
8.72" x 19.00" x 22.94"(5U) [221.5 x 482.6 x 582.5] 17.44" x 19.00" x 22.94" (10U) [443.0 x 482.6 x 582.5] 26.16" x 19.00" x 22.94" (15U) [664.5 x 482.6 x 582.5]
8.72" x 19.00" x 22.94"(5U) [221.5 x 482.6 x 582.5]
8.72" x 19.00" x 22.94"(5U) [221.5 x 482.6 x 582.5] 17.44" x 19.00" x 22.94" (10U) [443.0 x 482.6 x 582.5] 26.16" x 19.00" x 22.94" (15U) [664.5 x 482.6 x 582.5]
115 / (52) 230 / (104) 345 / (156) 71 / (32) 104 / (47) 136 / (62) 169 / (77) 100 / (45) 160 / (73) 320 / (146) 480 / (219)
(4) HR12150W Batteries per string 2000VA
8.72" x 19.00" x 22.94"(5U) [221.5 x 482.6 x 582.5] 17.44" x 19.00" x 22.94" (10U) [443.0 x 482.6 x 582.5] 26.16" x 19.00" x 22.94" (15U) [664.5 x 482.6 x 582.5] 8.72" x 19.00" x 22.94"(5U) [221.5 x 482.6 x 582.5] 17.44" x 19.00" x 22.94" (10U) [443.0 x 482.6 x 582.5] 26.16" x 19.00" x 22.94" (15U) [664.5 x 482.6 x 582.5]
141 / (64) 282 / (128) 423 / (192) 88 / (40) 136 / (62) 272 / (124) 408 / (186)
(6) HR12150W Batteries per string 3000VA
Note:
1. Battery Times are based on new batteries +/- 5%. 2. Extended Battery Packs are Hot Swappable, not individual batteries. 3. Weight includes total number of all cabinets. 4. Consult Factory for longer Run Times.
8.72" x 19.00" x 22.94"(5U) [221.5 x 482.6 x 582.5] 17.44" x 19.00" x 22.94" (10U) [443.0 x 482.6 x 582.5] 26.16" x 19.00" x 22.94" (15U) [664.5 x 482.6 x 582.5]
*Always reference Spec Control Drawing (SCD) for the most current & accurate dimensions and weights
Staco Energy Products Co.
193 / (88) 386 / (176) 579 / (264)
Staco Service
Field Service Program Staco specializes in providing choice and flexibility by developing tailored solutions for preventive and remedial maintenance services, as well as emergency repairs for all of our products. Staco Service is built upon a nationwide network of highly trained and motivated customer support engineers and technicians who can provide professional services and care throughout the life of your equipment.
Start-Ups n Preventive Maintenance n Spare Parts n Battery Analysis/Refresh/Replacement n On-Site Training n Time & Material Services n ServiStar: Providing security beyond our n
standard warranty
Why Staco Energy Products?
Because we are your tailored power solutions provider! Unique application design demands, harsh environment concerns, the need to meet nonstandard physical space requirements— providing the “not so usual” is what we do best. From leading edge uninterruptible power supplies, power conditioners, power factor and harmonic correction equipment, to the world’s most stable voltage control systems, we have the technology you need to protect and manage your business, and the knowledge to make it work for you. Since 1937, customers worldwide have relied on Staco Energy as their tailored solutions provider, to solve a wide range of electrical power problems. Headquartered in Dayton, Ohio, Staco Energy Products is a wholly owned subsidiary of Components Corporation of America, located in Dallas, Texas.
Contact Us: US Toll Free: 866-261-1191 Phone: 937-253-1191 E-mail:
[email protected]
Your Tailored Power Solutions ProviderTM ©2016, Staco Energy Products Co.
UniStarV_230_bro-161130
For more information go to: www.stacoenergy.com