Series 7 Power Controllers Data Sheet

   EMBED


Share

Transcript

Series 7 Power Controllers Series 7 DIN Rail Mount Power Devices Series 7 Power Devices put 12 to 80 Amps in a DIN rail mount package that provides precision machine control for heater bands, cartridge heaters, and other resistive loads. • DIN Rail or Wall Mounting • Zero Crossing Control • AC/DC ON-OFF or mA Proportional Inputs • SCR or Triac Version • No Need for External Wire Crimping Introduction The Series 7 Power Device family features a sleek design and robust performance specifications which ensure that your tough heating requirements are surpassed. These devices were developed to control resistive heating loads using the time proportional SSR driver output or the linear output from a temperature controller. Specifically tuned to ensure quick temperature ramping, precise operating control, and immediate temperature stabilization, all these features mean better product homogeneity, less wasted time and less scrap. The Series 7 Power Device family consists of: Model 7PT 7PD 7PA 7PL 7PM 7PE 7PB 7PF Vac 240 400 & 600 400 & 600 400 & 600 400 & 600 400 & 600 400 & 600 400 & 600 Phase Single Single Single Single Single Three Three Three Device Triac SCR SCR SCR SCR Two leg SCR Two leg SCR Two leg SCR Control On-off On-off On-off On-off Proportional On-off On-off On-off Input Vdc Vdc 100/240 Vac 24 Vac 4 to 20 mA Vdc 100/240 Vac 24 Vac Features • • • • Thermal Protection Option When the junction temperature reaches 125°C (257°F), a separator inhibits the command signal and turns on the OH LED indicator. Once the heat sink temperature becomes acceptable, the command signal is again enabled and the OH LED is turned off. 1415-DB-010-0-01 All models can be DIN rail or Panel mounted Complete line and load connections provided for easy installation All terminals accessible from the front Common height for all models Barber-Colman Company 1 Series 7 Power Controllers Input ON-OFF Control Mode On Off Time Line Output Cycle time defined by controller Time In the On-Off control mode, the output of the contactor turns on only when the input is turned on and the supply voltage is at a zero-crossing point. If the input is turned on at a non-zero point, the contactor will simply wait for the next zero-point to turn on. Unlike a mechanical relay, the Series 7 with On-Off control eliminates electrical switching disturbances and audible noise. Fast Cycle Proportional Control Mode (7PM only) Input 20 mA 12 mA 4 mA Status 0 50 100 Time (Line Periods) 50 100 Time (Line Periods) 50 100 % Output On The Fast Cycle control mode is a zero-crossing firing mode that uses a fixed 100-cycle time base for control. For example, 50 cycles on and 50 cycles off results in a 50% output. Fast Cycle control is best for loads that need the slower, less frequent switching (i.e., resistive loads). Line Output Off Input Single Cycle Proportional Control Mode (7PM only) 20 mA 16 mA 12 mA 8 mA 4 mA Status 0 % Output 25 50 75 100 On Off Line Period @ 50 Hz = 20 ms @ 60 Hz = 16.6 ms Line Output 0 A1 B1 0 to A1 = 1 line period 0 to B1 = 4 line periods 2 0 A2 B2 0 0 to A2 = 1 line period 0 to B2 = 2 line periods A3B3 Single Cycle control mode is a zero-crossing firing mode that uses a variable time base (ontime plus off-time) for control. Based on the command level, the time base is kept at a minimum, which improves control compared to the Fast Cycle control mode. For example, one cycle on and one cycle off results in a 50% output. Three cycles on and one cycle off results in a 75% output. Single Cycle control is best for loads that require faster, more precise control (i.e., low thermal inertia loads). 0 to A3 = 3 line periods 0 to B3 = 4 line periods Barber-Colman Company 1415-DB-010-0-01 Series 7 Power Controllers Ordering Information MODEL: Field No. 7P 2 3 4 5 6 7 Field 1. RESERVED Fields 2, 3, 4. BASE MODEL 7PT - Solid State Contactor, 1Ø, Triac, DC Volt, On/Off 7PD- Solid State Contactor, 1Ø, SCR, DC Volt, On/Off 7PA - Solid State Contactor, 1Ø, SCR, 100/240 Vac, On/Off 7PL - Solid State Contactor, 1Ø, SCR, 24 Vac, On/Off 7PM- Power Controller, 1Ø, SCR, 4 to 20 mA, Proportional 7PE - Solid State Contactor, 3Ø, SCR, DC Volt, On/Off 7PB - Solid State Contactor, 3Ø, SCR, 100/240 Vac, On/Off 7PF - Solid State Contactor, 3Ø, SCR, 24 Vac, On/Off 8 9 0-0-00 10 11 12 13 14 15 Fields 8, 9, 10. LOAD VOLTAGE 240 - 240 Volts/800 V Peak Reverse (7PT only) 400 - 400 Volts/1200 V Peak Reverse 600 - 600 Volts/1700 V Peak Reverse Field 11. THERMAL PROTECTION 0 - None 1 - Over Temperature Protection Fields 12 through 15. RESERVED Fields 5, 6, 7. LOAD AMPERES T12- 12 Amps (7PT only) T18 -18 Amps (7PT only) 020 - 20 Amps (7PB, 7PE, 7PF) 025 - 25 Amps (7PA, 7PD, 7PL, 7PM) 035 - 35 Amps (7PA, 7PD, 7PL, 7PM) 040 - 40 Amps (7PB, 7PE, 7PF) 045 - 45 Amps (7PA, 7PD, 7PL, 7PM) 060 - 60 Amps (7PA, 7PB, 7PD, 7PE, 7PF, 7PL, 7PM) 080 - 80 Amps (7PA, 7PD, 7PL, 7PM) Output Specifications Model 7PT Nominal Voltage 240V Nominal Current* 12A Non-repeatable Surge Current 160A 128 I2t for fusing (10 ms) Non-repeatable Peak Voltage 900V ∆V/∆t 250V/µs Peak Reverse Voltage 800V 18W Total Power Dissipation (I=Imm) Weight (grams) 510g 240V 18A 208A 259 900V 250V/µs 800V 27W 510g Models 7PA , 7PL, 7PD and 7PM Nominal Voltage 400V Nominal Current* 25A Non-repeatable Surge Current 280A I2t for fusing (10 ms) 550 Non-repeatable Peak Voltage 1300V ∆V/∆t 500V/µs Peak Reverse Voltage 1200V Total Power Dissipation (I=Imm) 30W Weight (grams) 630g 1415-DB-010-0-01 400V 35A 400A 860 1300V 500V/µs 1200V 45W 630g 400V 45A 400A 860 1300V 500V/µs 1200V 55W 900g 400V 60A 1200A 10180 1300V 500V/µs 1200V 75W 1100g 400V 80A 1200A 10180 1300V 500V/µs 1200V 100W 2000g Barber-Colman Company 600V 600V 600V 600V 600V 25A 35A 45A 60A 80A 280A 400A 400A 1200A 1200A 550 860 860 10180 10180 1700V 1700V 1700V 1700V 1700V 1000V/µs 1000V/µs 1000V/µs 1000V/µs 1000V/µs 1600V 1600V 1600V 1600V 1600V 30W 45W 55W 75W 100W 630g 630g 900g 1100g 2000g 3 Series 7 Power Controllers Models 7PB and 7PE and 7PF Nominal Voltage 400V Nominal Current* 20A Non-repeatable Surge Current 280A I2t for fusing (10 ms) 550 Non-repeatable Peak Voltage 1300V ∆V/∆t 500V/µs Peak Reverse Voltage 1200V Total Power Dissipation (I=Imm) 50W Weight (grams) 1800g 400V 40A 400A 860 1300V 500V/µs 1200V 90W 1800g 400V 60A 1200A 10180 1300V 500V/µs 1200V 130W 1800g 600V 600V 600V 20A 40A 60A 280A 400A 1200A 550 860 10180 1700V 1700V 1700V 1000V/µs 1000V/µs 1000V/µs 1600V 1600V 1600V 50W 90W 130W 1800g 1800g 1800g Input Specifications Minimum Holding Current Leakage Current Minimum Latching Voltage Voltage Drop on Power Semiconductor Control Type Control Voltage Input Current Insulation between Power Circuit and Earth Insulation between Command and Power Circuits Insulation Resistance 4 7PT Single Phase 7PD Single Phase 7PA Single Phase 7PL Single Phase 7PM Single Phase 7PE Three Phase 7PB Three Phase 7PF Three Phase 50 mA rms 50 mA rms 500 mA rms 500 mA rms 50 mA rms 50 mA rms 500 mA rms 500 mA rms 10 mA rms 10 mA rms 10 mA rms 10 mA rms 10 mA rms 10 mA rms 10 mA rms 10 mA rms 20V 20V 40V 40V 20V 20V 40V 40V 1.8V 1.2V 1.2V 1.2V 1.2V 1.2V 1.2V 1.2V On/Off Off <2 On/Off Off <2 On/Off Off <2 On 4.5 to 35 Vdc 15 mA 15 mA On/Off Off < 4 Vac On 24 Vac (±15%) < 33 mA Linear On 4.5 to 35 Vdc On/Off Off < 10 Vac On 100 to 240 Vac (±10%) < 33 mA 4 to 20 mA 15 mA On/Off Off < 10 Vac On 100 to 240 Vac (±10%) < 33 mA On/Off Off < 4 Vac On 24 Vac (±15%) < 33 mA 1800 Vrms for 1 minute 3000 Vrms for 1 minute 2200 Vrms for 1 minute 2200 Vrms for 1 minute 3000 Vrms for 1 minute 3000 Vrms for 1 minute 2200 Vrms for 1 minute 2200 Vrms for 1 minute 7500 Vpk for 1 minute 7500 Vpk for 1 minute 3500 Vpk for 1 minute 3500 Vpk for 1 minute 7500 Vpk for 1 minute 7500 Vpk for 1 minute 3500 Vpk for 1 minute 3500 Vpk for 1 minute >100MΩ at 500 Vdc >100MΩ at 500 Vdc >1MΩ at 500 Vdc (400V) >2MΩ at 500 Vdc (600V) >100MΩ at 500 Vdc On 9 to 35 Vdc Operational Temperature 0 to 50°C (32 to 122°F) Humidity 20 to 85% RH, non-condensing Storage Temperature -20 to 70°C (-4 to 158°F) Protection IP20 Mounting Vertical; rear of board on wall or DIN rail Terminals Screw, with front access Load Type Resistive Barber-Colman Company 1415-DB-010-0-01 Series 7 Power Controllers Recommended Fusing Contactor/Power Controller Amps - Volts 12 - 240 Model 7PT 18 - 240 25 - 400 35 - 400 45 - 400 Model 7PA, 7PD, 7PL & 7PM 60 - 400 80 - 400 Fuse Model 6600.CP.URGB.14.51/20 Bussman FWP.20B.14F Ferraz 6600.CP.URGB.14.51/32 Bussman FWP.30B.14F Ferraz 6600.CP.URGA.22X58/32 Bussman FWP.32A.22F Gould 52443 Ferraz 6600.CP.URGA.22X58/50 Bussman FWP.50A.22F Gould 53251 Ferraz 6600.CP.URGA.22X58/50 Bussman FWP.50A.22F Gould 53251 Ferraz 6600.CP.URGA.22X58/80 Bussman FWP.80A.22F Gould 53259 Ferraz 6600.CP.URGA.22X58/100 Bussman FWP.100A.22F Gould 53263 20 - 600 Ferraz 6600.CP.URD.22X58/32 35 - 600 Ferraz 6600.CP.URD.22X58/50 45 - 600 Ferraz 6600.CP.URD.22X58/50 60 - 600 Ferraz 6600.CP.URD.22X58/80 80 - 600 20 - 400 40 - 400 Model 7PB, 7PE & 7PF 1415-DB-010-0-01 Supplier Ferraz Ferraz 6600.CP.URD.22X58/100 Ferraz 6600.CP.URGA.22X58/32 Bussman FWP.32A.22F Gould 52443 Ferraz 6600.CP.URGA.22X58/50 Bussman FWP.50A.22F Gould 53251 Ferraz 6600.CP.URGA.22X58/80 60 - 400 Bussman FWP.80A.22F Gould 53259 20 - 600 Ferraz 6600.CP.URD.22X58/32 40 - 600 Ferraz 6600.CP.URD.22X58/50 60 - 600 Ferraz 6600.CP.URD.22X58/80 Barber-Colman Company 5 Series 7 Power Controllers Single Phase Wiring WARNING! The SSR assembly is not a replacement for a disconnect switch, which must always be installed in the supply feeder! Model 7PD, 7PM, 7PT Power Line Model 7PA, 7PL Power Line L1 N Earth Single Phase Connection 1 Single Phase Connection 2 1 L1 N Earth Barber-Colman 3 5 6 3 4 OH SV LOW HIGH AT ON 3 LOW OUT 4 HIGH AT A/C Source AT FUNC 5 6 7SD Three Phase Without Neutral Connection 1 2 1 Three Phase Without Neutral Connection 2 1 2 1 3 5 OH SV 6 4 3 5 6 4 ON OH 4 3 ON LOW OUT AT 3 5 6 HIGH 7SD 3 4 3 ON OH 4 3 5 6 Delta Connection Star Connection Without Neutral Star Connection Without Neutral Power Line 1 2 1 1 2 2 1 1 2 2 5 6 4 ON 4 5 6 1 R/L1 S/L2 T/L3 N Earth Three Phase With Neutral Connection 1 2 1 2 1 2 2 1 1 2 2 1 2 Controller Barber-Colman Barber-Colman 3 5 6 4 3 5 6 4 3 5 6 3 4 °F SV AT 5 6 4 3 5 6 4 3 5 6 4 °F OH 3 ON OH 4 3 ON OH 4 3 FUNC 7SD ON ALM Star Connection With Neutral 5 6 5 6 4 OUT OH SV LOW AT 5 6 Signal 6 A/C Source Delta Connection R/L1 S/L2 T/L3 N Earth HIGH 6 Signal Controller LOW AT FUNC 5 6 Signal Three Phase With Neutral Connection 5 OH 4 AT AT 2 °F SV ALM FUNC 7SD OUT 1 Barber-Colman 3 ALM 2 2 Controller °F Power Line 1 2 Barber-Colman HIGH 4 5 6 2 1 1 Controller LOW 3 Power R/L1 Line S/L2 T/L3 Earth Power R/L1 Line S/L2 T/L3 Earth AT 4 ON Signal Signal OUT 6 OH SV ALM FUNC 7SD ALM 5 °F °F AT 2 Controller Barber-Colman OUT 2 1 2 Controller ALM 1 HIGH AT FUNC 7SD A/C Source 3 ON OH 4 3 5 6 5 6 ON OH 4 3 ON 4 5 6 Signal Star Connection With Neutral Barber-Colman Company 1415-DB-010-0-01 Series 7 Power Controllers Mounting Model 7PT Dimensions shown in inches (millimeters in parenthesis) 2 OH 5.31 (135) 1 4.92 (125) 2.52 (64) 1.77 (45) 4.65 (118) 3.82 (97) 3.39 (86) ON 3 4 56 Ø 0.177 (04.5) 1 (25) 1.38 (35) 12 - 18 Amps Model 7PD, 7PA, 7PL, 7PM Dimensions shown in inches (millimeters in parenthesis) 2 4.65 (118) 1.77 (45) 4.92 (125) 1 1 2 3 564 OH ON 3 4 5.31 (135) 2.52 (64) 4.78 (121.5) 4.33 (110) 56 Ø 0.177 (04.5) 1 (25) 1.38 (35) 25 - 35 Amps 1415-DB-010-0-01 Barber-Colman Company 7 Series 7 Power Controllers Mounting (continued) Model 7PD, 7PA, 7PL, 7PM Dimensions shown in inches (millimeters in parenthesis) 2 4.65 (118) 1.77 (45) 4.92 (125) 1 1 5.31 (135) 2.52 (64) 4.78 (121.5) 4.33 (110) 2 3 564 OH ON 3 4 56 1 (25) 2.07 (52.5) Ø 0.177 (04.5) 45 Amps Model 7PD, 7PA, 7PL, 7PM Dimensions shown in inches (millimeters in parenthesis) 4.78 (121.5) 4.33 (110) 1 2 2 5.31 (135) 1 4.92 (125) 4.65 (118) 1.77 (45) 2.52 (64) 2.07 (52.5) 3 564 OH ON 3 4 56 Ø 0.177 (04.5) 1 (25) 2.75 (70) 60 Amps 8 Barber-Colman Company 1415-DB-010-0-01 Series 7 Power Controllers Mounting (continued) Model 7PD, 7PA, 7PL, 7PM Dimensions shown in inches (millimeters in parenthesis) 1 (25) 1 (25) 1.77 (45) Ø 0.177 (04.5) 3 5.31 (135) 4.92 (125) 1 OH 2 ON 4 5.31 (135 ) 80 Amps 1415-DB-010-0-01 Barber-Colman Company 9 Series 7 Power Controllers Three Phase Wiring WARNING! The SSR assembly is not a replacement for a disconnect switch, which must always be installed in the supply feeder! Model 7PE Model 7PB, 7PF Power R/L1 Line S/L2 T/L3 Earth Power R/L1 Line S/L2 T/L3 Earth Three Phase Without Neutral Connection 1 3 Three Phase Without Neutral Connection 5 SV AT HIGH OH ON °F °F LOW 5 Barber-Colman Barber-Colman ALM 3 Controller Controller OUT 1 AT OH ON 2 4 SV ALM LOW OUT 6 HIGH AT FUNC FUNC A1A2 7SD AT 7SD A/C Source Signal Signal Delta Connection Delta Connection Star Connection Without Neutral Star Connection Without Neutral 4 2 6 A1A2 Mounting Model 7PB, 7PE, 7PF Dimensions shown in inches (millimeters in parenthesis) OH 2 0.177 (04.5) 10 3 5 5.31 (135) 1 4.92 (125) 1.77 (45) 4.65 (118) 2.52 (64) 4.78 (121.5) 4.33 (110) ON 4 6 4.15 (105.5) Barber-Colman Company 1 (25) 1415-DB-010-0-01 Series 7 Power Controllers Formulas Sizing Power/nominal current conversion The following formulas are provided to simplify model selection. These formulas enable you to calculate the nominal current of each SSR when the total load power is known. The load must be resistive so that in the following formulas, the cos ø will be considered equal to 1. The formulas related with the three phase application are referred to a balanced three phase system only. Single Phase Connection I RMS = where: P VRMS P = Power (in Watts) VRMS = Phase to neutral or phase to phase voltage IRMS = Nominal line current Three Phase Without Neutral Connection (Star or Delta Application) I RMS = where: P VRMS • 3 P = Total load power (in Watts) VRMS = Phase to phase voltage IRMS = Nominal line current Three Phase With Neutral Connection (Star Application) I RMS = where: P VRMS • 3 P = Total load power (in Watts) VRMS = Phase to neutral voltage IRMS = Nominal line current Heat Generated by the Solid State Contactors Full Load Current x 1.2 volts* x # of Legs of Control = Watts *1.8 volts for 7PT Example 7PE calculation: 60 amps x 1.2 volts x 2 = 144 Watts 1415-DB-010-0-01 Barber-Colman Company 11 Barber-Colman Company 741-F Miller Drive, Leesburg, VA 20175-8993 Phone: 703-443-0000 Fax: 703-669-1300 http://www.barber-colman.com An Invensys company Copyright © 2000 Barber-Colman Company