Preview only show first 10 pages with watermark. For full document please download

Series Amsr1-78-nz Up To 12 Watt | Dc-dc Converter

   EMBED


Share

Transcript

Series AMSR1-78-NZ Up to 12 Watt | DC-DC Converter FEATURES: • • • • 3 Pin SIP Package Pin-out compatible with LM78XX Linear Regulators Short Circuit Protection Non-Isolated Regulated Outputs • • • • Operating temperature -40°C to +85°C Wide input range Very High Efficiency Up To 96% Low ripple and noise Models Single output Model Input Voltage (V) Output Voltage (V) Output Current max (A) Efficiency Vin Min (%) Efficiency Vin Max (%) 4.75-28 6.5-32 9.0-32 12-32 16-32 3.3 5 6.5 9 12 1 1 1 1 1 90 93 94 95 96 83 88 90 92 94 AMSR1-783.3-NZ AMSR1-7805-NZ AMSR1-786.5-NZ AMSR1-7809-NZ AMSR1-7812-NZ Input Specifications Input Specifications Voltage range Filter Quiescent Current Short Circuit consumption Nominal Typical Maximum Units 4.75-32 Capacitor 5 0.5 7 1.2 mA W Conditions Typical Maximum Units 100% load Continuous ±2 Auto recovery ±3 % . 2 Internal IC junction 10-100% load Vin=(LL-HL) at full load 10-100% load -40°C to +85°C ambient 20MHz Bandwidth 150 ±100 ±0.4 ±0.6 ±0.02 35 2000 A ºC mV % % %/oC m Vp-p µF Conditions Typical Maximum Units 100% load With derating above 71°C 330 -40 to +85 -55 to +125 Vin=(LL-HL) at full load Output Specifications Output Specifications Voltage accuracy Short Circuit protection Short circuit restart Output current limit Thermal shutdown Dynamic load stability Line voltage regulation Load voltage regulation Temperature coefficient Ripple & Noise Maximum Capacitive Load General Specifications Input Specifications Switching frequency Operating temperature Storage temperature Max Case temperature Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF www.aimtec.com F 051e R3 KHz o C o C 100 Free air convection 95 Non-conductive black plastic (UL94V-0 rated) 3.7 g 0.45 X 0.35 X 0.69 inch 11.50 X 8.90 X 17.50 mm > 2 000 000 hrs (MIL-HDBK-217F, Ground Benign, t=+25°C) Tel: +1 514 620 2722 1 of 3 % g Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMSR1-78-NZ Up to 12 Watt | DC-DC Converter Pin Out Specifications Pin Single 1 2 3 +Vin GND +Vout Dimensions Footprint 0.45 (11.5) 0.35 (8.9) Front View Ø 0.04 +0.006/ -0 (Ø 1.0 + 0.15/ -0 Side View 0.69 (17.5) 0.1 (2.54) 0.1 (2.54) DIV: 0.1 (2.54) 0.16 (4.1) 1 2 Dimensions: inch (mm) General Tolerance:± 0.01 (0.25) Pin Tolerance: ± 0.004 (0.1) 3 0.024 (0.5) 0.02 (0.5) Derating Free Air Convection Bottom View 0.012 (0.3) 71 º C 0.085 (2.15) 100 80 0.126 (3.21) 0.1 0.1 (2.54) (2.54) 0.126 (3.21) Safe Operating Area 60 40 20 0 -40 -20 0 20 40 60 80 100 Ambient Temperature º C www.aimtec.com F 051e R3 Tel: +1 514 620 2722 2 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMSR1-78-NZ Up to 12 Watt | DC-DC Converter Typical Application Circuit Vin 3 1 AMSR1-78XX-NZ C1 22µF GND 2 Vout C2 100µF GND C1: A low ESR capacitor is required to keep the converter to a minimum. Ceramic capacitors are recommended, but tantalum or electrolytic may be used. Typical value is 22µF / 50V. C2: Installation of C2 is recommended but optional. Typical value 100µF / 25V electrolytic. NOTE: It is not recommended to connect in parallel. NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 5. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. www.aimtec.com F 051e R3 Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only