Transcript
Series AZ16
For Industrial Trucks
for industrial trucks
AZ16
General: The AZ16E-302 conduces in combination with two sensors AZS as altitude indicator, e.g. in an industrial truck with two telescope syllabuses. At this unit the two sensors will be automatically cyclical elected and the sum of both positions (H1+H2) is shown on the display. This is in accordance with the lift fork of the lift truck. The AZ16E-302 comprises a special software for that application.
Product Features: ■ ■ ■ ■ ■ ■ ■ ■
No reference run necessary Battery powered Absolute Retrofit Easy mountable Wearless Resistant against dirt Maximum measuring length 16m
Principle / Schematic Diagram
1 Indicator AZ16E-302
2 Segment 1 is in passive state
3
4
The lift fork moves relatively to segment 1.
The lift fork is located at the end of Segment 1.
5 Segment 1moves relatively to the lift truck (Segment 2).
The lift fork is at the end of segment 1. Segment 1 moves relatively to the lift truck (Segment 2).
H2 = 0 Sensor 2 an Stapler mounted on lift truck montiert
Segment 1is in idle mode. The lift fork moves relatively to Segment 1.
H2
Sensor 1 an Sensor1 Gabel montiert
mounted on lift fork
H1
Sensor Sensor 2 2
an Stapler
mounted on montiert lift truck
Sensor 1 mounted lift fork an Gabelonmontiert H1 Anzeigewert Display value:= H1 + H2 + H2
(= H2)
Display value: Anzeigewert = H1 H1 + + H2H2
Technical specifications:
Order reference:
Power supply
1.5 V battery (size C)
For orders, please use the following order code:
Battery life span
1… 3 years (depends on adjusted switch on time)
Distance sensor/tape
Max. 1.5 mm
Resolution of sensor
0.1 mm
Measurement units
MM or INCH
Max. measuring distance
8m
Max. length of sensor cable
20.0 m
Principle of measurement
Magnetic, absolute
Kind of measurement
Linear, no rotative tasks possible
LCD-Display
6 digits, height 8 mm, +sign, + battery condition
Keypad
Membrane keypad
Operation temperature
+5… +50°C
Stock temperature
0… 70°C
Humidity
Non condensing max. 80%
Protection class (indicator)
IP 43 installed state
Outer dimension (indicator)
B x H = 96 x 72 mm
Panel cut out
B x H = 93 x 67 mm
For Example:
Depth AZ16 E incl. sensor connector
(depth) 47 mm (depth with connectors) 53 mm
AZ16E - 3 0 2 - 1 - 0 1 . 0 - 1 - A G A A A - B - C C.C - D - E E
Protection external Sensor
IP 67
Dimension external Sensor
See drawings
AZ16E - _ _ _ - _ - _ _ . _ - _ - _ _ A A A - B - C C . C -D - E E A
Version 302 = 3 Axes indicator (Sensors AZS as accessories available)
B Supply 1 = 1x C sized battery internal C Length of sensor cable Standard Length: 1 m (see sensors AZS)
D Cable options 1 = pluggable via RJ45– plug E Options AG = Assembly Housing
AZ16E-302, with supply through an internal C sized battery, 1 m Sensor cable, a RJ45-plug and with assembly housing.
Your Order:
AZ16E - _ _ _ - _ - _ _ . _ - _ - _ _ A A A - B - C C . C -D - E E Dimensions: Dimensions Indicator
External magnet sensor AZS
5.5
87 4
17
34
R4 72
66
4
6
96
Ø6
Ø 3,4
* *minus 9 mm, connector bendable minus 9 mm, da Stecker biegbar 63
9
34
25 37 Schalttafel-Ausbruchmaß: Panel cut out B x H = 93 x 67 mm
1 100
12
92
27 43
Order reference: For orders, please use the following order code:
AZS - _ _ _ - _ - _ _ . _ - _ A A A -B -CC.C -D A Version 000 Standard 001 First special version B Sensor type 1 AZSensor-100 / for max. 8m measuring length C Sensor cable length Standard length: 1 m (further lengths for additional charge; max. 20 m) D Cable options 1 Cable outlet with RJ45– plug (Standard)
For example: AZS - 0 0 0 - 1 - 0 1 . 0 - 1 A A A - B - C C.C - D AZS Sensor ELGO Standard with Sensor for max. 8 m measuring lengths,1.0 m Sensor cable and a cable outlet with a RJ45 connector.
Your Order:
AZS - _ _ _ - _ - _ _ . _ - _ A A A -B -CC.C -D
Accessories: AB20AB20-4040-1010-1-R-11
Magnetic tape, with 4.0 mm pole width and INOX-cover band.
Doc.-No. 799000429 AZ16E-302.-E_48-08