Preview only show first 10 pages with watermark. For full document please download

Series Exl-n

   EMBED


Share

Transcript

Sealed lead-acid cell EXL-N Series Model: EXL 1200N EUROPOWER cells are made in AGM technology. Owing their excellent power and current capability these batteries are designed for both large and important central battery UPS systems as well as for applications in telecommunications and renewable energy engeneering (the battery system capacity even up to 12000 Ah). They have a very high repeatibility of parameters and long designed life. EXL-N cells can withstand 1200 discharge/charge cycles at 80% DOD. TECHNICAL DATA APPLICATIONS *) - According to Eurobat (Long Life group) Ÿ Ÿ high power Uninterruptible Power Supplies (UPS) substations emergency lighting systems Ÿ Ÿ Ÿ telecommunication power plants renewable power sources GSM base stations DIMENSIONS 225(8.86) 229(9.02) mm(inch) 100(3.94) 98 % 86 % 73 % ABS UL 94-HB ABS UL 94-V0** I3 10,0 Nm TERMINALS I3 3.5(0.138) after 1 month after 6 months after 12 months standard Container material optional Terminal insert terminal Terminal hardware initial torque Capacity retention o during storage @ 20 C (self discharge) Ÿ 555(21.85) 566(22.28) 2V 1200 Ah / C10 1 AGM o over 17 years @ 20 C* Design life o over 15 years @ 25 C height 566,0 mm length Dimensions 225,0 mm width 229,0 mm Weight ~75,0 kg 1240,0 Ah 10h 124A @1,80V/cell. 942,0 Ah 314A @1,80V/cell. 3h Capacity o 663,0 Ah 663A @1,75V/cell. 1h @ 25 C 457,0 Ah 30 min 914A @1,75V/cell. o o charge Ambient nominal 0 C ~ 40 C o o temperature discharge -40 C ~ 55 C range o o storage -20 C ~ 40 C Internal resistance @ fully charge battery £0,17 mW 2,25 V standby use o (-3 mV/ C) Charging voltage o @ 20 C 2,35 V cycle use o (-4 mV/ C) recommended 120 A Charging current maximum 300 A 108(4.25) Nominal voltage Nominal capacity Cell per unit Technology M8 **) - Flame-retardant NO TRANSPORT RESTRICTED Not restricted for air, surface and water transport. Classified as nonhazardous material (IATA/ICAO Special Provision A67, DOT-CFR Title 49 parts 171-189, IMDG amendment 27) [Bolt M8] DISCHARGE CHARACTERISTICS o o • Constant current (Current [A], 25[ C] / 77[ F]) F.V. V/cell 1,90 1,85 1,83 1,80 1,75 1,70 5 min 15 min 30 min 45 min 1h 3h 5h 6h 8h 960 1172 1264 1365 1444 1531 768 972 1052 1143 1226 1302 625 752 798 855 914 991 533 638 685 724 767 814 460 556 594 630 663 702 257 288 304 314 321 328 181 200 210 214 219 222 159 175 183 185 189 192 128 141 146 147 150 152 o o • Constant power (Power [W/cell], 25[ C] / 77[ F]) F.V. V/cell 1,90 1,85 1,83 1,80 1,75 1,70 5 min 15 min 30 min 45 min 1h 3h 5h 6h 8h 1890 2249 2400 2550 2670 2784 1512 1866 1998 2136 2266 2368 1197 1464 1584 1695 1814 1929 984 1200 1309 1405 1507 1608 889 1049 1145 1224 1330 1410 558 612 634 648 668 682 392 420 432 444 456 464 346 366 377 388 396 408 283 302 312 320 328 335 Discharge time 10h 24h 108 119 123 124 125 126 51,6 55,3 56,9 56,9 58,2 58,7 Discharge time 10h 24h 242 257 266 271 276 278 107 114 117 119 121 122 F.V. - Final voltage EXL-N EXL 1200N Cell life characteristics of standby use Cell life characteristics of cycle use 20 Temperature: o o 25[ C] / 77[ F] 120 Charging voltage 2.275 V/cell 15 100 Retention Capacity [%] Life expantancy [year] 10 8 6 5 4 3 80 60 100[%] Depth of discharge 80[%] D.O.D 50[%] D.O.D 30[%] D.O.D 40 20 2 0 1.4 20 68 30 86 40 104 0 [oC] o [ F] 50 122 600 1200 1800 2400 3000 3600 Number of cycles Battery Temperature Cell discharge characteristics Cell self discharge characteristics 100 Terminal Voltage [V] Capacity Retention Ratio [%] Temperature: o o 25[ C] / 77[ F] 2.1 2.0 1.9 0.05C[A] 0.3C[A] 0.2C[A] 0.4C[A] 0.5C[A] 0.6C[A] 0.7C[A] 0.8C[A] 0.9C[A] 1.0C[A] 1.8 0.014C[A] 0.1C[A] 1.7 80 10[oC]/50[oF] 60 40[oC]/104[oF] 20[oC]/68[oF] 30[oC]/86[oF] 40 1.6 0.01 0.1 1 5 10 20 50 100 Discharge time [hr] 0 3 6 9 12 15 18 21 24 27 30 Storage time [months] Cell charging characteristics for the standby use Cell charging characteristics for the cycle use 0.21 140 2.50 0.21 2.50 140 Charge voltage 2.35 0.06 2.35 100 0.15 2.25 Charge voltage 80 2.15 Discharge 100% (0.05C[A] x 20[h]) 50% (0.05C[A] x 10[h]) Charging constant voltage: 2.275[V/cell] constant current: 0.1C[A] o o Temperature: 20[ C](68[ F]) 2.05 1.95 120 60 40 20 0.03 0.12 0.09 0.06 Charge vo 2.15 0 0 4 8 12 16 Charge time [hr] 20 100 80 Discharge 100% (0.05C[A] x 20[h]) 50% (0.05C[A] x 10[h]) Charging constant voltage: 2.45[V/cell] constant current: 0.1C[A] o o Temperature: 20[ C](68[ F]) 2.05 1.95 60 40 0.03 20 Charge current Charge current 0 lume Charge volume [%] 0.09 0.18 Charge voltage [V] 0.12 120 lume Charge current [CxA] 2.25 0.15 Charge voltage [V] Charge current [CxA] Charge vo Charge volume [%] 0.18 0 0 0 0 4 8 12 16 Charge time [hr] 20 0 Cell discharge current and final discharge voltage Discharge current [A] Final discharge voltage [V/cell] 0.2C > I 0.2C £ I < 0.5C 0.5C £ I < 1.0C 1.0C £ I 1.85 1.83 1.75 1.70 Pb *) C - Capacity Date of issue: 16.03.2010; change number: 2; date of change: 19.05.2015 EXL-N