Preview only show first 10 pages with watermark. For full document please download

Series Ip100 Ion Pump Power Supply Datasheet

   EMBED


Share

Transcript

Series IP100 ION PUMP POWER SUPPLY FEATURES 115W Output Power 90V to 265V AC Operation Positive or Negative polarity to order Compact size Lightweight Protection against output short circuit Current monitor Interlock EU RoHS compliant to 2002/95/EC DESCRIPTION The Series IP100 is a range of high voltage power supplies designed to drive a vacuum chamber ion pump where a vacuum in the region of 1x10E-11 Torr is required. The Series IP100 is also suitable for use in mass spectrometers, scanning electron microscopes and high integrity vacuum systems. Operation: A mains ON/OFF switch, ENABLED indicator lamp and fuse are provided on the front panel. HV Enable and a Current Monitor are provided via a 9-way D-type connector situated on the rear panel. A current monitor is also provided via 4mm banana sockets. Output Voltage: 5kV or 7kV depending on model. Current Monitors: Fibre optic transmitter:  A series of light pulses, where the frequency is directly proportional to the load current over the range 1µA to 2mA. 1mA load gives 30kHz. (Frequency (Hz) = load current x 30E6) ±5%.) 4mm sockets or 9-way D-type (pins 3 or 4):  A voltage directly proportional to the load current over the range 1µA to 2mA. (1mA load = 4.7V monitor ±5%.) Output Current: 80mA max. Remote Enable: The presence of a 24V supply fed remotely enables the supply. Input Voltage: 90V to 265V AC. Operating Temperature: 10oC to 40oC. Input Current: 2A max. Altitude: Sea level to 2000 metres (6500 feet). Polarity: Positive or negative to order. Humidity: 80%. Output Ripple: Less than 30V peak to peak. Assembly: The unit incorporates an air insulated HV assembly to achieve a total weight of less than 1.6kg (3.5 lb). SPECIFICATION Output Power: 115W output at 240V input. w w w. h i t e k p o w e r. c o m Series IP100 ION PUMP POWER SUPPLY Protection: Robust design ensures that the power supply is immune to output short circuit. Safety: An interlock is provided which disables the power supply when the cover is removed. The Series IP100 meets the requirements of the Low Voltage Directive (LVD) 2006/95/EC by complying with BS EN61010 when it is installed as a component part of compliant equipment. It is CE marked accordingly. RoHS: The Series IP100 meets the requirements of EU Directive 2002/95/EC on the Restriction of use of Certain Hazardous Substances in electrical and electronic equipment (RoHS). Mechanical Specification: Dimensions: See outline drawing. Weight: 1.6kg (3.5 lb). Outputs & Ordering Information: Model no Output Voltage Output Current IP100/502* 5kV 80mA IP100/702* 7kV 80mA * Please add suffix P (Positive) or N (negative) to the model number for the required polarity. eg: part number for a 7kV positive unit: IP100/702P. For voltages not listed above, please contact our sales team. If required, this unit can be configured to meet the requirements of RoHS providing a significant quantity is ordered - please contact our sales team. Interface Connection: Mains: IEC320 mains receptable. HV Output: FISCHER 105 series Current Monitor: 4mm isolated sockets HV Enable/Current Monitor via a 9-way D-type connector: GROUND 1 NO CONNECTION 2 MONITOR GND 3 MONITOR OUTPUT 4 ENABLE 24V - Ve 5 6 ENABLE 24V + Ve 7 NO CONNECTION 8 NO CONNECTION 9 NO CONNECTION These component power supplies meet the requirements of EC Directive 2006/95/EC (LVD). w w w. h i t e k p o w e r. c o m Design developments may result in specification changes Drawing dimensions are in mm (inches) Series IP100 ION PUMP POWER SUPPLY w w w. h i t e k p o w e r. c o m UK HiTek Power Ltd Hawthorn Road, Littlehampton West Sussex BN17 7LT UK Tel: +44 (0) 1903 712400 Fax: +44 (0) 1903 712500 e-mail: [email protected] USA HiTek Power Inc 124 Jewett Street, Unit #2 Georgetown, MA 01833-1868 USA Tel: +1 (978) 352-9100 Fax: +1 (978) 352-9133 e-mail: [email protected] GERMANY HiTek Power GmbH Joh.-Friedr.-Boettger-Str. 21 D-63322 Roedermark Germany Tel: +49 (0) 6074 69285 0 Fax: +49 (0) 6074 69285 10 e-mail: [email protected] JAPAN HiTek Power Japan 1-5-13 Kyutaroumachi Chou-ku, Osaka 541-0056 Japan Tel: +81 (6) 6271 8180 Fax: +81 (6) 6271 8190 e-mail: [email protected] Issue 2: 5/2013 w w w. h i t e k p o w e r. c o m