Transcript
Data Sheet No. PD10060 revK
Series PVT412APbF Microelectronic Power IC
HEXFET Power MOSFET Photovoltaic Relay ®
Single Pole, Normally Open, 0-400V, 240mA AC / 360mA DC
General Description
The PVT412A Series Photovoltaic Relay is a singlepole, normally open solid-state relay that can replace electromechanical relays in many applications. It util izes International Rectifier’s proprietary HEXFET power MOSFET as the output switch, driven by an integrated circuit photovoltaic generator of novel construction. The output switch is controlled by radiation from a GaAlAs light emitting diode (LED) which is optically isolated from the photovoltaic generator. These SSRs are specifically designed for industrial control and peripheral telecom applications. Series PVT412A Relays are packaged in a 6-lead molded DIP package with either thru-hole or surface mount (‘gull-wing’) terminals. It is available in standard plastic shipping tubes or on tape-and-reel. Please refer to part identification information .
Features HEXFET Power MOSFET output Bounce-free operation 4,000 VRMS I/O isolation Very low on-resistance (RDD-ON) Linear AC/DC operation Solid-State Reliability UL Recognized ESD Tolerance: 4000V Human Body Model 500V Machine Model
Applications
Control of AC power line (up to 240 VAC) industrial loads Control of DC industrial loads up to +/-300 VDC On/Off hook switch Dial-pulse generation
Part Identification PVT412APbF PVT412ASPbF PVT412AS-TPbF
thru-hole surface-mount surface-mount, Tape and Reel
(HEXFET is the registered trademark for International Rectifier Power MOSFETs)
www.irf.com
1
Series PVT412APbF
Electrical Specifications 0-400V, 240ma,AC (TA =
+25°C) unless otherwise specified)
INPUT CHARACTERISTICS
Limits
3.0 to 25 6.0
mA V
Limits
Units
Minimum Control Current (see figure 1) Maximum Control Current for Off-State Resistance Control Current Range (Caution: current limit input LED, see figure 5) Maximum Reverse Voltage
a OUTPUT CHARACTERISTICS
3.0 0.4
Operating Voltage Range Maximum Load Current @ TA=+40°C 5mA Control (see figure 1) A Connection B Connection C Connection Maximum On-State Resistance @TA=+25°C 100mA Pulsed Load, 5mA Control (see figures 2 & 3) A Connection B Connection C Connection Max. pulsed Load Current @TA=+25°C, ±400V, 5mA Control (10mS @ 10% duty cycle) Maximum Off-State Leakage @TA=+25°C, ±400V Maximum Turn-On Time @TA=+25°C (see figures 6 & 7) For 50mA, 100 VDC load, 5mA Control (5mS pulse width @ 50% duty cycle) Maximum Turn-Off Time @TA=+25°C (see figures 6 & 7) For 50mA, 100 VDC load, 5mA Control (5mS pulse width @ 50% duty cycle) Maximum Output Capacitance @ 50VDC, f=1MHz (Cout, see figure 8)
0 to ±400
GENERAL CHARACTERISTICS
Limits
Minimum Dielectric Strength, Input-Output Minimum Insulation Resistance, Input-Output Maximum Capacitance, Input-Output Vd=0V, f=1MHz Maximum Pin Soldering Temperature (10 seconds maximum) Ambient Temperature Range: Operating Storage
Units mA mA
V peak
240 260 360
mA mA mA
6 3 2 750 1.0
Ω Ω Ω mA µA
3.0
ms
0.5 40.0
ms pF
4000 1012 1.0 +260 -40 to +85 -40 to +100
Units VRMS Ω pF °C
International Rectifier does not recommend the use of this product in aerospace, avionics, military or life support applications. Users of this International Rectifier product in such applications assume all risks of such use and indemnify International Rectifier against all damages resulting from such use.
Connection Diagrams
www.irf.com
2
Series PVT412APbF
300
800 600 400
200
L oad C urrent (mA )
Max. Load Current (mA)
250
“A” Connection
“A” Connection
ILED = 5mA
ILED = 3mA 150
100
200
-3.0
-2.0
-1.0
0
0.0
-400 -600
50
1.0
2.0
3.0
-200
I L E D = 5mA 20mS P u ls ed, 25C
-800
0
Vo lta ge D r op (V DD )
0
20
40
60
80
Ambient Temperature (C)
100
Figure 1. Current Derating Curves
800
I
700
LED
Figure 2. Typical On Characteristics
= 5mA
“A” Connection
600
L oad C urrent (mA )
20 m S - P u l s e d , 25 ºC 500 400
25-40º C 60ºC 85ºC
300 200 100 0
0. 0
0.5
1.0
1. 5
2. 0
2.5
3.0
3. 5
VDD (Volts) Ambient
Ambient Temperature (oC)
Figure 3. Typical On-Characteristics
Figure 4. Typical Normalized Off-State Leakage
www.irf.com
3
Series PVT412APbF
10.00
“A” “A” Connection Connection
Tdly
Ton
0
0.5
Delay T ime (mS )
it & -45°C lim max. device
TYPICAL
min. devic
e & +85°C
limit
Input Current (mA)
1.00
1.0
Toff Toff
0.10
1.5
0.01
2.0
1
2
3
4
5
6
7
8
9
10
40
45
50
I LE D ( mA)
LED Forward Voltage Drop (Volts DC)
Figure 6. Typical Delay Times
Figure 5. Input Characteristics (Current Controlled)
400
“A” Connection
350
T ypic al C apac itanc e (pF )
300
ILED 90%
I D
10% tdly ton
toff
Figure 7. Delay Time Definitions
www.irf.com
250 200 150 100 50 0
0
5
10
15
20
25
30
35
VDD Drain to DrainCapacitance Voltage Figure 8. Typical Output
4
Series PVT412APbF
Case Outlines
01-2008 01
01-2009 01
www.irf.com
IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245 Tel: (310) 252-7105 Data and specifications subject to change without notice. 2/2008
5