Preview only show first 10 pages with watermark. For full document please download

Series Pvx6012pbf Igbt Photovoltaic Relay General Description Features

   EMBED


Share

Transcript

Data Sheet No. PD 10046 revH Series PVX6012PbF Microelectronic Power IC Relay IGBT Photovoltaic Relay Single Pole, Normally Open, 0-280VAC (RMS) or 0-400VDC, 1.0A AC/DC General Description The PVX6012 Photovoltaic Relay is a single-pole, normally open solid-state relay that can replace electromechanical relays in many applications. It utilizes an IGBT output switch, driven by an integrated circuit photovoltaic generator of novel construction.The output switch is controlled by radiation from aGaAlAs light emitting diode (LED) which is optically isolated from the photovoltaic generator. he PVX6012 is ideally suited for switching medium power loads. It offers high operating speed, low and stable on-state voltage drop as well as low off-state leakage current. PVX6012 relays are packaged in a 14-pin, molded DIP package in thru-hole. It is available in standard plastic shipping tubes. Features        IGBT and HEXFRED™ output Bounce-free operation 3,750 VRMS I/O isolation High load current capacity Low off-state leakage current Solid-State Reliability UL Recognized Applications  Test Equipment  Industrial Controls and Automation  Electromechanical Relay Replacement  Mercury-wetted Relay Replacement Part Identification PVX6012PbF thru-hole (HEXFET is the registered trademark for International Rectifier Power MOSFETs) www.irf.com 1 Series PVX6012PbF Electrical Specifications (-40°C < TA < +85°C unless otherwise specified) INPUT CHARACTERISTICS Minimum Control Current (see figure 1) Maximum Control Current for Off-State Leakage @ TA=+25°C Limits Units 5.0 0.4 mA mA Control Current Range (Caution: current limit input LED, see figure 6) Maximum Reverse Voltage 5.0 to 25 6.0 OUTPUT CHARACTERISTICS mA V Limits Units 600 0-280 0-400 1.0 1.0 V (DC or AC peak) V(AC) RMS V (DC) A(DC) A(AC) RMS 5 20 A(DC) A(DC) Maximum On-State Voltage Drop @TA=+25°C For 1A pulsed load, 5mA Control (see figures 3 and 4) 2.5 V Maximum Off-State Leakage @TA=+25°C, ±400V (see figures 5) 10 µA Maximum Turn-On Time @TA=+25°C (see figures 8) 7 For 1A, 400 VDC load, 5mA Control Maximum Turn-ff Time @TA=+25°C (see figures 8) 1 For 1A, 400 VDC load, 5mA Control Maximum Output Capacitance @ 100VDC (see figures 7) 50 ms Transient Overvoltage Protection Operating Voltage Maximum Load Current @TA=+40°C 5mA Control (see figures 1 amd Note 1) Maximum Surge Current @TA=+40°C non-repetitive, 1 sec. non-repetitive, 20 msec. (see figure 2) GENERAL CHARACTERISTICS Minimum Dielectric Strength, Input-Output Minimum Insulation Resistance, Input-Output @ TA=+25°C, 50%RH, 100 VDC Maximum Capacitance, Input-Output Maximum Pin Soldering Temperature (10 seconds maximum) Ambient Temperature Range: Operating Storage International Rectifier does not recommend the use of this product in aerospace, avionics, military or life support applications. Users of this International Rectifier product in such applications assume all risks of such use and indemnify International Rectifier against all damages resulting from such use. www.irf.com Limits 3750 1012 1.0 +260 -40 to +85 -40 to +100 ms pF Units VRMS Ω pF °C Connection Diagram Output AC or DC Load 2 Series PVX6012PbF 1.4 25 Max . DC Surge Current (A) 1 0.8 0.6 0.4 0.2 20 40 60 80 10 5 0 0.01 100 0.02 0.05 Am bie nt T e m per ature (de g. C) 2.5 L oad C urrent (Amps ) 1.0 0.5 -1.5 -1.0 0.0 -0.5 0.0 -0.5 0.5 1.0 1.5 2.0 2.5 3.0 -1.0 -1.5 -2.0 V f-On (Normaliz ed to 25 deg. C ) 1.5 -2.0 0.95 -25 20 e a nd +85 d eg . C lim it 8 M in. d e vic Input Current (mA) 25 deg. C 12 Ic o ff /Ic o ff 10 4 65 85 105 Ambient Temperature (deg. C) Figure 5. Typical Normalized Off-State Leakage www.irf.com 50 CAUTION: provide current limiting so that 25 mA maximum steadystate control current rating is not exceeded 16 45 25 75 100 125 Figure 4. Typical Normalized VCEON 1000 25 0 Amb ient Tem perature (deg .C) Figure 3. Output Characteristics 5 10 1 V oltage Drop (V d d) -15 5 1.05 0.9 -50 -2.5 0.1 -35 1 1.1 2.0 -2.5 0.5 Figure 2. Surge Current Capability Figure 1. Current Derating Curves -3.0 0.1 Surge D ura tion ( Sec.) 0 0 a nd -40 de g . C lim it 0 15 M a x. d e vic e 0 20 TYPIC AL L oad C urrent (Amps ) 1.2 0.5 1.0 2.0 1.5 LED Forwa rd Voltag e Drop (Volts DC) Figure 6. Input Characteristics (Current Controlled) 3 Series PVX6012PbF 6 Delay T ime (millis ec onds ) 30 Typic al C apa c itanc e (pF ) 28 26 24 22 20 18 16 14 12 5 4 2 1 0 10 100 200 300 400 500 TON 3 TOFF 5 10 Figure 7. Typical Output Capacitance Case Outlines 20 L E D C urr ent (mA) Vcc , C ollec tor to C ollec tor Voltage (V) Figure 8. Typical Delay Time Figure 9. Delay Time Definitions 01-3062 00 www.irf.com IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245 Tel: (310) 252-7105 Data and specifications subject to change without notice. 2/2008 4