Transcript
Data Sheet No. PD 10046 revH
Series PVX6012PbF
Microelectronic Power IC Relay
IGBT Photovoltaic Relay
Single Pole, Normally Open, 0-280VAC (RMS) or 0-400VDC, 1.0A AC/DC
General Description The PVX6012 Photovoltaic Relay is a single-pole, normally open solid-state relay that can replace electromechanical relays in many applications. It utilizes an IGBT output switch, driven by an integrated circuit photovoltaic generator of novel construction.The output switch is controlled by radiation from aGaAlAs light emitting diode (LED) which is optically isolated from the photovoltaic generator. he PVX6012 is ideally suited for switching medium power loads. It offers high operating speed, low and stable on-state voltage drop as well as low off-state leakage current. PVX6012 relays are packaged in a 14-pin, molded DIP package in thru-hole. It is available in standard plastic shipping tubes.
Features
IGBT and HEXFRED™ output Bounce-free operation 3,750 VRMS I/O isolation High load current capacity Low off-state leakage current Solid-State Reliability UL Recognized
Applications
Test Equipment Industrial Controls and Automation Electromechanical Relay Replacement Mercury-wetted Relay Replacement
Part Identification PVX6012PbF
thru-hole
(HEXFET is the registered trademark for International Rectifier Power MOSFETs)
www.irf.com
1
Series PVX6012PbF
Electrical Specifications (-40°C < TA
< +85°C unless otherwise specified)
INPUT CHARACTERISTICS Minimum Control Current (see figure 1) Maximum Control Current for Off-State Leakage @ TA=+25°C
Limits
Units
5.0 0.4
mA mA
Control Current Range (Caution: current limit input LED, see figure 6) Maximum Reverse Voltage
5.0 to 25 6.0
OUTPUT CHARACTERISTICS
mA V
Limits
Units
600 0-280 0-400 1.0 1.0
V (DC or AC peak) V(AC) RMS V (DC) A(DC) A(AC) RMS
5 20
A(DC) A(DC)
Maximum On-State Voltage Drop @TA=+25°C For 1A pulsed load, 5mA Control (see figures 3 and 4)
2.5
V
Maximum Off-State Leakage @TA=+25°C, ±400V (see figures 5)
10
µA
Maximum Turn-On Time @TA=+25°C (see figures 8) 7 For 1A, 400 VDC load, 5mA Control Maximum Turn-ff Time @TA=+25°C (see figures 8) 1 For 1A, 400 VDC load, 5mA Control Maximum Output Capacitance @ 100VDC (see figures 7) 50
ms
Transient Overvoltage Protection Operating Voltage Maximum Load Current @TA=+40°C 5mA Control (see figures 1 amd Note 1) Maximum Surge Current @TA=+40°C non-repetitive, 1 sec. non-repetitive, 20 msec. (see figure 2)
GENERAL CHARACTERISTICS Minimum Dielectric Strength, Input-Output Minimum Insulation Resistance, Input-Output @ TA=+25°C, 50%RH, 100 VDC Maximum Capacitance, Input-Output Maximum Pin Soldering Temperature (10 seconds maximum) Ambient Temperature Range: Operating Storage International Rectifier does not recommend the use of this product in aerospace, avionics, military or life support applications. Users of this International Rectifier product in such applications assume all risks of such use and indemnify International Rectifier against all damages resulting from such use.
www.irf.com
Limits 3750 1012 1.0 +260 -40 to +85 -40 to +100
ms pF
Units VRMS Ω pF °C
Connection Diagram Output AC or DC Load
2
Series PVX6012PbF 1.4
25
Max . DC Surge Current (A)
1 0.8 0.6 0.4 0.2 20
40
60
80
10 5 0 0.01
100
0.02
0.05
Am bie nt T e m per ature (de g. C)
2.5
L oad C urrent (Amps )
1.0 0.5 -1.5
-1.0
0.0 -0.5 0.0 -0.5
0.5
1.0
1.5
2.0
2.5
3.0
-1.0 -1.5 -2.0
V f-On (Normaliz ed to 25 deg. C )
1.5
-2.0
0.95
-25
20
e a nd +85 d eg . C lim it
8
M in. d e vic
Input Current (mA)
25 deg. C
12
Ic
o ff
/Ic
o ff
10
4
65
85
105
Ambient Temperature (deg. C)
Figure 5. Typical Normalized Off-State Leakage
www.irf.com
50
CAUTION: provide current limiting so that 25 mA maximum steadystate control current rating is not exceeded
16
45
25
75
100
125
Figure 4. Typical Normalized VCEON
1000
25
0
Amb ient Tem perature (deg .C)
Figure 3. Output Characteristics
5
10
1
V oltage Drop (V d d)
-15
5
1.05
0.9 -50
-2.5
0.1 -35
1
1.1
2.0
-2.5
0.5
Figure 2. Surge Current Capability
Figure 1. Current Derating Curves
-3.0
0.1
Surge D ura tion ( Sec.)
0
0
a nd -40 de g . C lim it
0
15
M a x. d e vic e
0
20
TYPIC AL
L oad C urrent (Amps )
1.2
0.5 1.0 2.0 1.5 LED Forwa rd Voltag e Drop (Volts DC)
Figure 6. Input Characteristics (Current Controlled)
3
Series PVX6012PbF 6
Delay T ime (millis ec onds )
30
Typic al C apa c itanc e (pF )
28 26 24 22 20 18 16 14 12
5 4
2 1 0
10 100
200
300
400
500
TON
3
TOFF 5
10
Figure 7. Typical Output Capacitance
Case Outlines
20
L E D C urr ent (mA)
Vcc , C ollec tor to C ollec tor Voltage (V)
Figure 8. Typical Delay Time
Figure 9. Delay Time Definitions
01-3062 00
www.irf.com
IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245 Tel: (310) 252-7105 Data and specifications subject to change without notice. 2/2008
4