Preview only show first 10 pages with watermark. For full document please download

Series Sd

   EMBED


Share

Transcript

Series SD Dual Output to 50A 600 Vac DC Control Solid-State Relay FEATURES/BENEFITS The Series SD dual-phase relays are designed for all types of loads. The design incorporates two relays in a single package. The relays utilize optical isolation to protect the control from load transients. High-current models are excellent for motor and phase angle control. The 50A 600 Vac models are available with common control connector or individual control connector. Applications include motor control, heating control, uninterruptible power supplies, light dimmers, industrial and process control, and on/off controls of AC equipment. UL recognized. UL File Number: E1285555. • Designed for all types of loads • Dual output (two relays in one package) • Faston terminals • Connector for common or individual control • Tight zero-cross window for low EMI • High immunity to surges Part Number Description INPUT (CONTROL) SPECIFICATION SD24R50-06 12-280 Vac SD24R50 12-280 Vac Control Range SD24D40-06 12-280 Vac SD24D50-06 12-280 Vac SD48D40-06 24-500 Vac SD48D50A 24-600 Vac SD48D50A2 24-600 Vac Min Max Units SD24 4 30 Vdc SD48D40-06 5 30 Vdc SD48D50XX 10 30 Vdc Input Current Range All relays (See Fig. 3) 3 mA All relays 1 Vdc Part Number Explanation 48 SD R -06 50 Must Turn-Off Voltage Series Feature3 Switch Type2 Line Voltage1 Output Current - Amps NOTES 1) Line Voltage (nominal): 24 = 240 Vac; 48 = 480 Vac 2) Switch Type: R = Random turn-on; D = Zero-cross turn-on; 3) Features: -06 = Faston terminals A = Common control adapter A2 = Individual control adapter Input Resistance (Typical) SD24 1000 Ohms SD48D40-06 1000 Ohms SD48D50A 1400 Ohms SD48D50A2 1800 Ohms BLOCK DIAGRAM L +  – input Reverse Voltage Protection output All relays 30 V T L2 + 2 – input output T2 Figure 1a — All SD relays except SD48D40-06 L +  input – output T L2 + 2 – input output T2 Figure 1b — SD48D40-06 © 2007 TELEDYNE RELAYS SD  SD\052007\Q1 Series SD Dual Output to 50A 600 Vac DC Control Solid-State Relay MECHANICAL SPECIFICATION .2 (5.2) .0 (25.4) TOLERANCES: ± .02 .75 (44.5) 50A – 400Vac + (24-600Vac) Input 0-30 Vdc wEIgHT: 3.88 oz. (0g) T2 400Vac (24-600Vac) .2 (5.2) = L2 50A T .3 (7.75) .63 (6) max .20 (5.)  2 +–+– .2 (30) .67 (42.5) .4 (0.2) .87 (47.6) 3+ L .06 (27) .88 (22.4) .77 (9.6) 2.28 (58) M4 .4 (0.2) . (28) Ø.9 (4.7) = .35 (8.8) 2.28 (58) .83 (2) .5 (2.7) .024x.024 (0.6x0.6) .75 (44.5) .06 (27) .88 (22.4) .77 (9.6) 2~ 4- 2.28 (58) .67 (42.5) .25 (6.3) ~ T2 Figure 2b — SD24R50; dimensions in inches (mm) . (28) Ø.9 (4.7) – +2 – + T wEIgHT: 3.88 oz. (0g) Figure 2a — SD24R50-06 and SD24D50-06; dimensions in inches (mm) .26 (32) M4 L2 .3 (7.75) .2 (5.2) wEIgHT: 3.88 oz. (0g) L .39 (0) .32 .3 (7.62) (8) T2 2.28 (58) – +2 – + .8 (4.57) .4 (35.8) 0.3 (7.62) .44 (.) T .77 (9.6) . (28) Ø .9 (4.7) L2 .39 (0) .87 (47.6) .25x.03 (6.3x0.8) Ø .9 (4.7) L .75 (44.5) .06 (27) .88 (22.4) .77 (9.6) 0.9 (29.2) .87 (47.6) .75 (44.5) .87 (47.6) .26 (32) .63 (6) max Figure 2d — SD48D50A; dimensions in inches (mm) wEIgHT: 3.88 oz. (0g) TYPICAL APPLICATION Figure 2c — SD48D40-06 and SD24D40-06; dimensions in inches (mm) 3 phases 200 up to 480 Vac L .75 (44.5) .06 (27) . (28) .88 (22.4) .77 (9.6) M4 Ø.9 (4.7) L2 L3 .06 (27) .88 (22.4) .77 (9.6) 50A I (24-600Vac) I T 400Vac T2 400Vac  (24-600Vac) + .8 (20.4) L2 2 2.28 (58) + .87 (47.6) = L 50A = .8 (20.4) .67 (42.5) Y wiring .3 (7.75) Input 0-30 Vdc wEIgHT: 3.88 oz. (0g) .2 (5.2) .63 (6) max ∆ wiring .63 (6) max Figure 2e — SD48D50A2; dimensions in inches (mm) single phase Figure 3 — SD48D50A SD  Specifications are subject to change without notice © 2007 TELEDYNE RELAYS SD\052007\Q1 Series SD Dual Output to 50A 600 Vac DC Control Solid-State Relay OUTPUT (LOAD) SPECIFICATION Input Type Min Max OUTPUT (LOAD) SPECIFICATION (Continued) Units Operating Range Input Type Min Max Units Maximum di/dt (Non-Repetitive) SD24 R/D 12 SD48D40-06 SD48D50XX 280 Vrms 24 510 Vrms 24 600 Vrms All relays 50 A/µs 440 Hz Operating Frequency Range All relays 10 Peak Voltage SD24 600 Vpeak I2t for Match Fusing (<8.3ms) SD48 1200 Vpeak SD24D40-06 612 A2S SD48D40-06 612 A2S All other relays 1500 A2S SD24D40-06 .005 40 Arms SD48D40-06 .005 40 Arms All other relays .005 50 Arms Maximum Surge Current Rating (Non-Repetitive) SD24D40-06 350 A SD48D40-06 350 A All other relays 550 A All relays output current 1.6 V CONTROL CHARACTERISTICS Input Currrent (mA) Load Current Range (Resistive) On-State Voltage Drop 30 28 26 24 22 20 8 6 4 2 0 8 6 4 2 0 0 2 4 6 8 0 2 4 6 8 20 22 24 26 28 30 Control Voltage (V) Figure 4a — SD24 and SD48D40-06 relays 20 Zero-Cross Window SD R SD D/A NA ±12 Vac Off-State Leakage Current (60Hz) Input Current (mA) 8 6 4 2 0 8 6 4 2 2.5 SD48D40-06 All other relays 1 0 mA 0 5 0 5 20 25 30 35 Control Voltage (V) mA Figure 4b — SD48D50A relay 6 Turn-On Time (60 Hz) 5 4 SD24 R 0.1 ms All other relays 8.3 ms 3 Turn-Off Time (60 Hz) All relays 8.3 ms Input Current (mA) 2  0 For each input 9 8 7 6 5 4 3 2 Off-State dv/dt  0 All relays 500 V/µs 0 5 0 5 20 25 30 35 Control Voltage (V) Figure 4c — SD48D50A2 relay © 2007 TELEDYNE RELAYS SD  SD\052007\Q1 Series SD Dual Output to 50A 600 Vac DC Control Solid-State Relay THERMAL CHARACTERISTICS ENVIRONMENTAL SPECIFICATION Min Units 50 Operating Temperature –40 100 °C 30 Storage Temperature –40 100 °C 0 90 80 70 60 50 SD48D40-06 4000 Vrms All other relays 3300 Vrms 90°C . .3 2°C 5° /w C .6 /w °C /w 2°C /w 2.6 °C/w 40  pole 4°C/w 20 withou t heat 0 0 0 5 0 5 20 25 30 35 40 0 45 sink 0 20 30 Load Current (Arms) 40 50 60 70 80 90 00 0 Ambient Temperature (°C) Figure 6a — SD24 50A relays output current Output-Case Isolation SD24D40-06 2500 Vrms SD48D40-06 2500 Vrms 55 All other relays 3300 Vrms 45 Power Dissipation (w) 2. C/w 3° 2. 30 /w 2°  pole 35 0°C Vrms 2 pole 40 /w °C 0 .2 w C/ 3° 0. /w °C 55 /w °C 75 0 . /w C 9° ° C 2 ° /w C / 35 w °C /w . 6° C/ w . . 50 0. 3300 SD48D50XX 60 0. Output to Output Max Case Temperature (°C) 0. 9° C/ w 00 30 0°C/w Vrms /w 0.2°C 4000 2 pole /w °C 0.4 SD24D40-06 w C/ 5° 0.5 /w °C 75 0. 20 Input-Output Isolation 40 Power Dissipation (w) Max C/ 6° w C/ w 25 4°C 20 /w 5 0 All other relays 2500 Vrms withou 5 t heat sink 0 0 Junction-Case Thermal Resistance 5 0 5 20 25 30 Load Current (Arms) 35 40 0 20 30 40 50 60 70 80 90 00 0 20 25 Ambient Temperature (°C) Figure 6b — SD48D40-06 and SD24D24-06 output current SD24D40-06 1.1 °C/W SD48D40-06 1.1 °C/W 60 All other relays °C/W 40 0.5 0.3°C/w 2 pole 0.75°C/w 20 SURGE CURRENT Power Dissipation (w) 0.95°C/w 600 Non-Repetitive 400 Apeak 0 200 Repetitive with initial Tj = 70°C 00 80  pole .6°C/w 60 2.2°C/w 40 0 0.0 0. t (s)  0 Figure 5a — SD24 50A output current 6°C/w 20 0 0 400 5 0 5 20 25 30 35 40 45 50 Load Current (Arms) 0 0 20 30 40 50 60 70 80 90 00 Ambient Temperature (°C) Non-Repetitive Apeak 300 Figure 6c— SD48D50A and SD48D50A2 output current 200 00 Repetitive with initial Tj = 70°C 0 0.0 0.  0 t (s) Figure 5b — SD48 40A and SD24 40A output current 600 NOTES: 1. Electrical specifications at 25°C unless otherwise specified. 2. For 800Hz applications, contact factory. 3. For additional/custom applications, contact factory. Apeak Non-Repetitive 400 200 Repetitive with initial Tj = 70°C 0 0.0 0. OPTIONAL ADD-ONS t (s)  Figure 5c — SD48 50A output current SD  0 Please order add-ons separately: • -12 — Thermal pad installed. • -14 — Plastic touch-proof cover. Specifications are subject to change without notice © 2007 TELEDYNE RELAYS SD\052007\Q1