MULTIPLE SPLIT TYPE AIR CONDITIONERS Series CM05EU4-E High COP (energy consumption efficiency) Achieved Top class in the Industry Comparison of COP (energy consumption efficiency) <10 HP system> COP 4.0 3.5 50% Energy saving Comparing to the current energy saving type, 14.5% Energy saving COP upgraded by about 15%! 3.0 2.5 2.0 0 3.39 3.88 2.58 Comparing to our equivalent product 10 years before, COP upgraded by about 50%! (10HP equivalent model) Our equivalent product 10 years before CITY MULTI Inverter driven outdoor fan motor newly employed! R410A highly efficient inverter compressor employed! • Improvement of heat exchanger performance • Newly designed refrigerant circuit (low pressure loss) Resulting in Total Energy Conservation Heating operation range covers an outdoor temperature of down to -20˚C (wet bulb temperature) Operating range in cooling is from an outdoor temperature of -5˚C, while that in heating has expanded to an outdoor temperature of -20˚C! The operation range can now cover even cold regions. ✻ -12˚C~15˚C for PUMY series. Operable even in very cold regions Under heating -20˚C ✻ Outdoor temperature (wet bulb temperature) 15.5˚C ✻ Under cooling Outdoor temperature (dry bulb temperature) -5˚C -20 -10 0 10 20 30 43˚C 40 High static pressure of 60Pa achieved, the industry top class* Flexibility in air conditioning design has been enlarged with a high static pressure of 60Pa. (except PUMY series) Facilitated connection of supply hood *Optional parts Outdoor unit packing without using wooden materials The use of wooden frame for the transport of the outdoor unit has been discontinued. The structure is so designed that the unit can be transported with a forklift not using wooden frames or pallets. This contributes in reducing waste and preserving the global environment. Eliminating wood consumption thanks to the wooden packing discontinued. Transportable by a forklift without using pallets. Night Mode Quiet operation can reduce sound level of 8dB! (10HP) Front and rear double suction structure CITYMULTI Series Night mode quiet operation can reduce sound level by sensing ambient temperature condition. Air passage and machine compartment separated 57dB dB above ˚C 30 (10HP) 49dB dB below ˚C 30 *Needs to set night mode setting at the site. *Night mode could be turn off automatically due to ambient temperature and required capacity load condition. The front and rear double suction structure provides the smooth airflow to reduce the pressure loss, which results in low noise. The machine compartment is sealed up to attain the low noise level in all directions. (except PUMY series) “All Directions” Series provide for air conditioning comfort with MITSUBISHI ELECTRIC's leading edge technologies. Less cold draught, More comfort Only with MITSUBISHI ELECTRIC CITYMULTI Series can change the target evaporating temperature during cooling mode. Unit with higher off coil temperature can offer more comfort due less chance of cold draughts. Conventional Model CITYMULTI Cooling Operation Set Temperature of 14˚C (except PUMY series) By selecting a dip switch on the unit, a cooling operation set temperature of 14˚C is possible on the floor standing and ceiling concealed models. Suitable for lower set temperature applications like Gymnasiums etc,,,. Series Only with MITSUBISHI ELECTRIC High-capacity reluctance DC motor drive compressor Motor efficiency greatly improved + Reduced suction refrigerant heating loss Anti-Corrosion Blue Fin as a Standard! CITYMULTI Series will have an Anti-Corrosion heat exchanger (Blue Fin) as a standard. Industry Top class Low Noise Design New Fan Design City Multi Y/R2 VRF systems led the introduction of larger single fan rotors some ten years ago and achieved substantially lower noise levels over multiple designs. Continuing development in the areas of blade shape and weight has achieved higher performance and lower noise level. Conventional model fan New model fan Mitsubishi Electric City Multi Series – towards a new era of highly advanced air conditioning – As a market leading company, Mitsubishi Electric offers the "State of the Art" City Multi VRF system, adopting advanced refrigeration & control technology, thereby achieving high performance and ultimate design flexibility. 1 Series Product Lineup Outdoor Unit New Air Cooled System 4HP 5HP 6HP 8HP 10HP 12HP 14HP 16HP 18HP 20HP 22HP 24HP 26HP Heat Pump Heat Recovery 28HP 30HP 32HP 34HP 36HP 38HP 40HP 42HP 44HP 46HP 48HP 50HP Heat Pump Water Cooled System 8HP 10HP 16HP 20HP Heat Pump Heat Recovery PLFY-P VCM-E/VAM-E ........p.27, 28 / 41, 42 Indoor Unit PEFY-P VMH-E ........p.35 / 51, 52 PLFY-P VLMD-E ........p.29 / 43, 44 PCFY-P VGM-E ........p.36 / 53 PMFY-P VBM-E ........p.30 / 45 PKFY-P VAM-E/VGM-E /VFM-E ........p.37 / 54, 55 PEFY-P VMR-E-L/R New ........p.31 / 46 New PEFY-P VMS-E ........p.32 / 47 New PFFY-P VKM-E ........p.38 / 56 PFFY-P VLEM-E/VLRM-E ........p.39 / 57, 58 PEFY-P VML-E ........p.33 / 48 PEFY-P VMM-E ........p.34 / 49, 50 PEFY-P VMH-E-F ........p.40 / 59, 60 Lossnay/OA Processing Units Air Conditioning MANAGEMENT SYSTEM 2 FEATURES Effective space utilization thanks to a small installation space. The installation space of the outdoor unit has greatly been reduced. The reduction counts for about 33%* maximum comparing to our conventional CITY MULTI Series.*24·26HP outdoor units Effective utilization of vacant spaces The compact design and isolated installation of each unit allow utilization of vacant spaces effectively. conventional CITY MULTI 24 450 450 840 840 450 26 HP 33% 450 Easy installation even in a narrow space reduction 1990 2990 3.46m2 5.20m2 *Image of 28~32HP system Outdoor unit installation space (including service space) 4~6HP 8~14HP 16HP 1unit 18~26HP 1unit 28~32HP 1unit 34~50HP NEW 2units 2units Installation Space Air Cooled 1unit 1990 450 150 840 330 630 1740 840 450 1740 10 950 1690 840 1390 (1540) 150 450 10 0.61m2 450 990 0.99m2 450 990 1290 1990 1.72m2 2.24m2 3.46m2 WY Series (Heat Pump) 10HP 16HP 8HP Installation Space Water Cooled (upside piping) 1740 450 10 990 20HP 10 1990 100 (250) 450 840 840 450 450 2690 3.74(4.14)m2 8HP 6.94m2 WR2 Series (Heat Recovery) 10HP 16HP 20HP 550 550 550 550 450 450 450 450 1,980 1.98m2 1,980 990 0.99m2 1.98m2 Easy carrying-in by single package design Reduced carrying-in process thanks to the single package configuration For lifting up to building rooftop with a crane For field combining type As the lifting up and down operation is repeated frequently, the installation work longer. 3 One shot The CITY MULTI (4~26HP) can be delivered in one go, thus allowing far speedier installation. R2 WR2 The World's First and Only "2-Pipe" Heat Recovery System The Innovative BC Controller Which Makes a 2-pipe System Possible BC Controller Operation Operation primarily for cooling Check valve Cooling High Low pressure gas pressure Low pressure pipe gas Heat exchanger Compressor Fan Low pressure 2-phase Cooling Cooling High pressure gas Gas/liquid separator Heating Total heat recovery operation Operation primarily for cooling Outdoor unit 4-way valve Total heat recovery operation BC controller Switching valve Indoor unit Heating Low pressure gas Low pressure gas Cooling High pressure gas Cooling High pressure gas Low pressure gas Low pressure 2-phase High pressure liquid LEV High pressure 2-phase High pressure pipe Heating Low pressure gas High pressure gas Low pressure gas Low pressure 2-phase High pressure liquid High pressure 2-phase High pressure liquid R2 WR2 R2 WR2 Achieving smallest number of pipework connection thanks to 2-pipe system Heat Recovery System can create maximum of 15HP capacity from 10HP unit! Comparison of piping connection The waste heat recovery system in the refrigerant system increases the energysaving effect as the cooling and heating simultaneous operation is carried out. City Multi R2/WR2 =2 connections =3 connections Total number of connections 20 Outdoor unit BC Controller Outdoor unit input 10HP Cooling 5HP: Waste heat utilized A Heating 10HP, Cooling 5HP, Total 15HP Indoor unit output B Heating 7.5HP, Cooling 7.5HP, Total 15HP Cooling 10HP C ( Cooling capacity of each indoor unit is approx. 10/15 of the rating. ) Operation pattern of New City Multi R2 System 7.5HP Optimum operation pattern 10HP In the same mode, the compressor capacity is the maximum output (in this case 10HP). 15HP ( Heating indoor unit Indoor unit The total number of connections for City Multi R2 is only 68 when the 16 indoor units are installed. 10HP Total 15HP indoor unit is connected with 10HP outdoor unit. ) A Primarily heating operation B Total heat recovery operation 7.5HP 5HP 3-pipe type C Total number of connections 5HP 7.5HP 58 15HP 10HP Cooling indoor unit Outdoor unit R2 WR2 The more frequently cooling and heating simultaneous operation is carried out, the higher the energy-saving effect is. COP in heat recovery operation Branch unit Number of branches 2-pipe type 4 20 10 44 16 68 3-pipe type 58 154 – Energy consumption efficiency (COP) 8 Indoor unit Cooling and heating balance operation 7 Cooling and heating simultaneous and primarily cooling operation 6 Cooling and heating simultaneous and primarily heating operation 5 4 3 Cooling and heating non-simultaneous model 2 1 0 20 40 60 80 Heating 100 ratio 4 FEATURES Downsizing of refrigerant piping connections Gas Gas piping piping :: downed downed by by 2 sizes sizes Liquid Liquid piping piping :: downed downed by by 1 size size By making the connection diameter of refrigerant piping smaller, the piping space can be minimized, and the ease of field installation. Workability upgraded and the piping materials reduced. Comparison of piping size (for 10HP system) Conventional type List of major piping sizes System capacity 4~6HP system 8HP system 10/12HP system 14HP system 16HP system 18~26HP system 28~32HP system 34~50HP system CITY MULTI type Gas piping Liquid piping Gas piping Liquid piping φ28.58 φ12.7 φ22.2 φ9.52 (10HP (10HP system) system) Liquid piping φ9.52 Gas piping φ15.88 φ19.05 φ22.2 φ12.7 φ15.88 φ19.05 φ28.58 φ34.93 φ41.28 Significant reduction of field piping connections Eliminating the oil equalizing pipe (8~32HP) The single package design eliminates the oil equalizing pipe and the piping between outdoor units, thus upgrading the reliability, reducing complexity and reducing the installation cost. 4~14HP 16HP 18~26HP 28~32HP 34~50HP NEW Oil equalizing pipe not required Liquid piping Piping between units not required Gas piping Liquid piping Gas piping Liquid piping Gas piping Oil equalizing pipe not required Oil equalizing piping Liquid piping Connection spot : 6 Connection spot : 2 Gas piping Connection spot : 12 *The actual product may differ from the photo. Upgrading reliability by minimizing the number of parts and providing back up function 18~26HP 28~32HP In case of one compressor fails, Facilitating maintenance work by minimizing the number of parts, and upgrading reliability by simplifying construction designed 5 Compressor In case of one compressor fails, 34~50HP NEW Alternate operation Compressor Compressor Compressor backup operation Compressor Compressor backup operation Backup In case of operation malfunction mulfunction Realizing refrigerant piping total length of 400m* top class in industry *CITY *CITY MULTI MULTI R2 R2 Series Series S Series (4~6HP) Refrigerant Piping Restrictions Total length........................................................ Furthest length.................................................. Furthest length after first branch....................... Top-bottom differentials between units Between indoor unit and outdoor unit (outdoor unit is upper)...................................... Between indoor unit and outdoor unit (outdoor unit is lower)........................................ Between indoor units......................................... 120m or less 80m or less 30m or less 30m or less 20m or less 12m or less Y Series (8~32HP) Refrigerant Piping Restrictions Total length........................................................ Furthest length.................................................. Furthest length [equivalent length]................... Furthest length after first branch....................... Top-bottom differentials between units Between indoor unit and outdoor unit (outdoor unit is upper)...................................... Between indoor unit and outdoor unit (outdoor unit is lower)........................................ Between indoor units......................................... 300m or less 150m or less 175m or less 40m or less Y Series Outdoor unit 50m or less 40m or less* 15m or less Top-bottom differential 50m Furthest piping length 175m (equivalent length) (actual length 150m) * 4m or less in cooling at outdoor temperature 0˚C or lower. Indoor unit between indoor units top-bottom differential 15m Y Series (34~50HP) Refrigerant Piping Restrictions Total length........................................................ Furthest length.................................................. Furthest length [equivalent length]................... Furthest length after first branch....................... Between Main and Sub outdoor unit................. Top-bottom differentials between units Between indoor unit and outdoor unit (outdoor unit is upper)...................................... Between indoor unit and outdoor unit (outdoor unit is lower)........................................ Between indoor units......................................... Between Main and Sub outdoor unit................. 300m or less 150m or less 175m or less 40m or less 4m or less 50m or less Outdoor unit 40m or less* 15m or less 0.1m or less * 4m or less in cooling at outdoor temperature 0˚C or lower. Top-bottom differential 50m Indoor unit Furthest piping length 175m (equivalent length) (actual length 150m) between indoor units top-bottom differential 15m 6 FEATURES Realizing refrigerant piping total length of 400m* top class in industry *CITY *CITY MULTI MULTI R2 R2 Series Series R2 Series (P200, P250, P300, P350 type) Refrigerant Piping Restrictions Total length............................................................ Furthest length...................................................... Furthest length [equivalent length]........................ Difference between outdoor unit and BC controller unit................................................... Difference between BC controller main-unit and furthest indoor unit....................... Top-bottom differentials between units Between indoor unit and outdoor unit (outdoor unit is upper).... Between indoor unit and outdoor unit (outdoor unit is lower)..... Between indoor unit and BC controller................... Between indoor units............................................. R2 Series 300m or less (400m) *2 150m or less P200, P250, P300, P350 types 175m or less 110m or less 40m or less*3 Between indoor unit and BC controller topbottom differential 15m 50m or less 40m or less 15m or less (10m) *1 15m or less (10m) *1 *1. Value in ( ) is applied to the P200/P250 type indoor unit. *2. Please refer to 'refrigerant piping limits' (see the figure) in case of the total length is greater than 300m. *3. Please refer to 'Limits between BC controller - indoor unit' (see the figure) in case of the piping length between BC controller and furthest indoor unit is greater than 40m (except P250 indoor unit). *4. Do not use joint or header for P200/P250 type indoor unit. *5. Do not connect P200/P250 type indoor unit with the indoor unit of any other capacity at a same branch port. Outdoor unit Difference of height 50m Furthest piping length 175m (equivalent length) (actual length 150m) Between indoor units top-bottom differential 15m Between indoor unit and BC controller top-bottom differential 15m R2 Series (P200 ~ P650 type) R2 Series Refrigerant Piping Restrictions Total length............................................................ Furthest length...................................................... Furthest length [equivalent length]........................ Difference between outdoor unit and BC controller main-unit.......................................... Difference between BC controller main-unit and furthest indoor unit.......................... Top-bottom differentials between units Between indoor unit and outdoor unit [outdoor unit is upper].... Between indoor unit and outdoor unit [outdoor unit is lower]..... Between indoor unit and BC controller................... Between indoor units............................................. Between BC controller main-unit and sub-unit.............. Between indoor unit (BC controller main-unit) and indoor unit (BC controller sub-unit)....................... 300m or less (400m) *1 150m or less 175m or less 110m or less Top-bottom differential 50m 40m or less *2 Between indoor unit and BC controller topbottom differential 15m 50m or less 40m or less 15m or less 15m or less (10m)*3 15m or less 15m or less (10m)*3 * If indoor units (over 16 branches) are connected, two BC controller units are required and there must be three pipes between BC controllers. *1. Please refer to 'refrigerant piping limits' (see the figure) in case of the total length is greater than 300m. *2. Please refer to 'Limits between BC controller - indoor unit' (see the figure) in case of the piping length between BC controller and furthest indoor unit is greater than 40m (except P250 indoor unit). *3. Value in ( ) is applied to the P200/P250 type indoor unit. *4. Do not use joint or header for P200/P250 type indoor unit. Outdoor unit P200 ~ P650 types Furthest piping length 175 m (equivalent length) (actual length 150 m) Between indoor units top-bottom differential 15m Between indoor unit and BC controller top-bottom differential 15m In case of a BC controller unit (16 branches or less) • Refrigerant Piping Limits Main pipe and branch pipe: 2-pipe Piping total lenght (m) 400 350 Top-bottom differential 50m or less 300 40 50 60 70 80 90 100 110 Distance between outdoor unit and BC Controller (m) • Limits between BC contoller - indoor unit Distance between BC controller (Main) furthest indoor unit (m) Distribution sub-control 250 200 30 Between indoor units topbottom differential 15m or less 70 110 m or less between outdoor unit and BC controller (2-pipe) Three pipes between BC controllers Distribution control main-unit Between distribution controls top-bottom differential 15m or less 60 50 40 Maximum length between indoor unit and BC controller 40 m or less (2-pipe) 30 20 10 0 0 5 10 15 Height differential between BC controller (Main) - furthest indoor unit (m) 7 Outdoor unit In case of two BC controller units (Over 16 branches) Series Product Lineup Wide variation of outdoor unit to adapt with various applications. Series Type S Series A Heat Pump 4HP 5HP 6HP PUMY-P100YHM PUMY-P125YHM PUMY-P140YHM PUMY-P100VHM PUMY-P125VHM PUMY-P140VHM 8HP 10HP 12HP 14HP 16HP Heat Pump PUHY-P200YGM-A PUHY-P250YGM-A PUHY-P300YGM-A PUHY-P350YGM-A PUHY-P400YGM-A Y Series A – Cooling Only PUY-P200YGM-A PUY-P250YGM-A PUY-P300YGM-A PUY-P350YGM-A R2 Series A Heat Recovery PURY-P200YGM-A PURY-P250YGM-A PURY-P300YGM-A PURY-P350YGM-A PURY-P400YGM-A Series Type 24HP 26HP 18HP 20HP 22HP A Heat Pump PUHY-P450YGM-A PUHY-P500YGM-A PUHY-P550YGM-A PUHY-P600YGM-A PUHY-P650YGM-A R2 Series A Heat Recovery PURY-P450YGM-A PURY-P500YGM-A PURY-P550YGM-A PURY-P600YGM-A PURY-P650YGM-A 28HP 30HP 32HP A Heat Pump PUHY-P700YSGM-A PUHY-P750YSGM-A PUHY-P800YSGM-A Series Type Series Type Y Series Y Series 34HP 36HP 38HP 40HP 42HP 44HP 46HP 48HP 50HP A Heat Pump PUHY-P850YSGM-A PUHY-P900YSGM-A PUHY-P950YSGM-A PUHY-P1000YSGM-A PUHY-P1050YSGM-A PUHY-P1100YSGM-A PUHY-P1150YSGM-A PUHY-P1200YSGM-A PUHY-P1250YSGM-A Series Type Y Series Series Type 8HP 10HP 16HP 20HP WY Series W Heat Pump PQHY-P200YGM-A PQHY-P250YGM-A PQHY-P400YSGM-A PQHY-P500YSGM-A WR2 Series W Heat Recovery PQRY-P200YGM-A PQRY-P250YGM-A PQRY-P400YSGM-A PQRY-P500YSGM-A Type: A =Air Cooled. W =Water Cooled. 8 OUTDOOR UNIT Specifications & External Dimensions New S SERIES R410A Specifications Model name Power source Cooling capacity (Nominal) PUMY-P100YHM PUMY-P125YHM PUMY-P140YHM 3-phase, 380-400-415V, 50Hz 11.2 14.0 15.5 *1 kW 9,600 13,300 12,000 *1 kcal / h 38,200 52,900 47,800 *1 Btu / h 14,000 12,500 *2 kcal / h 5.32 3.30 4.27 Power input kW 8.51-8.09-7.80 5.28-5.02-4.84 6.83-6.49-6.26 Current input A 2.91 3.39 3.28 COP 15 ~ 24˚C (59~75˚F) Temp. range of Indoor W.B. - 5 ~ 46˚C (23~115˚F) cooling Outdoor D.B. 10 to 46˚C D.B.(50 to 115˚FD.B.) : in case of connecting PKFY-P20/P25 type indoor unit. 18.0 12.5 16.0 Heating capacity *3 kW 15,500 10,800 13,800 (Nominal ) *3 kcal / h 61,400 42,700 54,600 *3 Btu / h 5.32 3.63 4.29 Power input kW 8.51-8.09-7.80 5.81-5.52-5.32 6.87-6.52-6.29 Current input A 3.38 3.44 3.73 COP 15~27˚C (59~81˚F) Temp. range of Indoor temp. D.B. -12~15˚C (10~59˚F) Heating Outdoor temp. W.B. 50 ~ 130% of outdoor unit capacity Indoor unit Total capacity P20 ~ P140 / 1 ~ 8 P20 ~ P125 / 1 ~ 6 P20 ~ P140 / 1 ~ 8 connectable Model / Quantity 51/53 49/51 50/52 Noise level (measured in anechoic room) dB φ9.52 (φ3/8" ) Flare Liquid mm(in.) Diameter of φ15.88 (φ5/38" ) Flare mm(in.) refrigerant pipe Gas Galvanized steel sheet External finish 1,350 ✕ 950 ✕ 330 mm External dimension H ✕ W ✕ D 140 kg Net weight Salt-resistant cross fin & copper tube Heat exchanger Type Inverter scroll hermetic compressor Compressor Maker Mitsubishi Electric Corporation Starting method Inverter 2.9 1.9 2.4 Motor output kW Case heater kW Lubricant ✕ original charge MEL56 x 2.3 L m3 / min FAN Air flow rate 100 External static press. 0 Pa Type ✕ Quantity Propeller fan ✕ 2 Control, Driving mechanism DC-control, Direct-driven by motor kW Motor output 0.06 x 2 HIC circuit (HIC: Heat Inter-Changer) Protection High pressure protection High pressure sensor, High pressure switch 4.15 MPa Inverter circuit (COMP. / FAN) Over-heat protection, Over-current protection Compressor Discharge thermo protection, Over-current protection Fan motor Over-heat protection, Voltage protection Defrosting method Auto-defrost mode (Reversed refrigerant circle) Refrigerant Type x original charge R410A ✕ 8.5kg ( 19 lb) Control LEV circuit Standard Document Installation Manual attachment Accessory Grounded lead wire ✕ 2 Optional parts Joint: CMY-Y62G-F ; Header:CMY-Y64/68G-F Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to the Installation Manual. Remark *3 Nominal heating conditions *2 Nominal cooling conditions *1 Nominal cooling conditions Unit converter Note: 20˚CDB (68˚FDB) Indoor: 27˚CDB/19˚CWB (81˚FDB/66˚FWB) 27˚CDB/19.5˚CWB (81˚FDB/67˚FWB) kcal= kW ✕ 860 7˚CDB/6˚CWB 35˚CDB (95˚FDB) Outdoor 35˚CDB (95˚FDB) Btu/h= kW ✕ 3,412 7.5m (24-9/16ft) 5m (16-3/8ft) Pipe length: 7.5m (24-9/16ft) cfm= m3/min ✕ 35.31 0m (0ft) 0m (0ft) Level difference: 0m (0ft) lb= kg/0.4536 * Nominal condition *1, *3 are subject to JIS B8615-1 * The specification data is subject to rounding variation. * Due to continuing improvement, above specifications may be subject to change without notice. 9 OUTDOOR UNIT Specifications & External Dimensions New S SERIES R410A Specifications Model name Power source Cooling capacity (Nominal) PUMY-P100VHM PUMY-P125VHM PUMY-P140VHM 1-phase, 220-230-240V, 50Hz 220V,60Hz 11.2 15.5 14.0 *1 kW 9,600 13,300 12,000 *1 kcal / h 38,200 52,900 47,800 *1 Btu / h 10,000 14,000 12,500 *2 kcal / h 3.34 5.35 4.32 Power input kW 15.4/14.8/14.1 15.4 24.7/23.6/22.7 24.7 20.0/19.1/18.3 20.0 Current input A 3.35 2.90 3.24 COP 15 ~ 24˚C (59~75˚F) Temp. range of Indoor W.B. - 5 ~ 46˚C (23~115˚F) cooling Outdoor D.B. 10 to 46˚C D.B.(50 to 115˚FD.B.) : in case of connecting PKFY-P20/P25 type indoor unit. 12.5 18.0 16.0 Heating capacity *3 kW 10,800 15,500 13,800 (Nominal ) *3 kcal / h 42,700 61,400 54,600 *3 Btu / h 3.66 5.58 4.33 Power input kW 16.9/16.2/15.5 16.9 25.8/24.7/23.6 25.8 20.0/19.1/18.3 20.0 Current input A 3.42 3.23 3.69 COP 15~27˚C (59~81˚F) Temp. range of Indoor temp. D.B. -12~15˚C (10~59˚F) Heating Outdoor temp. W.B. 50 ~ 130% of outdoor unit capacity Indoor unit Total capacity P20 ~ P125 / 1 ~ 6 P20 ~ P140 / 1 ~ 8 connectable Model / Quantity 51/53 49/51 50/52 Noise level (measured in anechoic room) dB φ9.52 (φ3/8" ) Liquid Liquid mm(in.) Diameter of φ15.88 (φ5/38" ) Gas mm(in.) refrigerant pipe Gas Galvanized steel sheet External finish 1,350 ✕ 950 ✕ 330 mm External dimension H ✕ W ✕ D 127 kg Net weight Salt-resistant cross fin & copper tube Heat exchanger Type Inverter scroll hermetic compressor Compressor Maker Mitsubishi Electric Corporation Starting method Inverter 3.3 2.2 Motor output kW 2.9 Case heater kW Lubricant ✕ original charge MEL56 x 2.3 L m3 / min FAN Air flow rate 100 External static press. 0 Pa Type ✕ Quantity Propeller fan ✕ 2 Control, Driving mechanism DC-control, Direct-driven by motor kW Motor output 0.06 x 2 HIC circuit (HIC: Heat Inter-Changer) Protection High pressure protection High pressure sensor, High pressure switch 4.15 MPa Inverter circuit (COMP. / FAN) Over-heat protection, Over-current protection Compressor Discharge thermo protection, Over-current protection Fan motor Over-heat protection, Voltage protection Defrosting method Auto-defrost mode (Reversed refrigerant circle) Refrigerant Type x original charge R410A ✕ 8.5kg ( 19 lb) Control LEV circuit Standard Document Installation Manual attachment Accessory Grounded lead wire ✕ 2 Optional parts Joint: CMY-Y62G-F ; Header:CMY-Y64/68G-F Only one indoor unit of Fresh Air type is connected with one outdoor unit. Remark Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to the Installation Manual. *1 Nominal cooling conditions *2 Nominal cooling conditions *3 Nominal heating conditions Unit converter Note: Indoor: 27˚CDB/19˚CWB 27˚CDB/19.5˚CWB 20˚CDB kcal= kW ✕ 860 Outdoor 35˚CDB 35˚CDB 7˚CDB/6˚CWB Btu/h= kW ✕ 3,412 Pipe length: 10m 5m 10m cfm= m3/min ✕ 35.31 Level difference: 0m (0ft) 0m (0ft) 0m (0ft) lb= kg/0.4536 * Nominal condition *1, *3 are subject to JIS B8615-1 * The specification data is subject to rounding variation. * Due to continuing improvement, above specifications may be subject to change without notice. 10 OUTDOOR UNIT New Specifications & External Dimensions S SERIES R410A External Dimensions PUMY-P100,125,140YHM / PUMY-P100,125,140VHM Unit : mm Rear Air Intake Service space 2-12 X 36 Oval holes (Foundation Bolt M10) 500 Air Discharge 70 56 ( 950 Rear Air Intake 322 Handle for moving 42 417 370 330 FOUNDATION Over 56 10 10m m 37 Ov er Side Air Intake 28 Over m 175 Installation Feet 53 0m 15 600 30 er 175 Piping and wiring connections can be made from 4 directions: FRONT,Right,Rear and Below. m 0m Less than Ov 15 30 er Ov 500 mm Over 10 150 Over FREE er 2-U Shaped notched holes (Foundation Bolt M10) 4 PIPING-WIRING DIRECTIONS Please secure the unit firmly with 4 foundation (M10) bolts. (Bolts and washers must be purchased locally.) Dimensions of space needed for service access are shown in the below diagram. The diagram below shows a basic example. Explantion of particular details are given in the installation manuals etc. Ov 3 FOUNDATION BOLTS 19 2 SERVICE SPACE 1 FREE SPACE (Around the unit) Ground for the power supply Side Air Intake Terminal connection Left····· For the power supply Center·····For the transmission line Right····· For concentration control ) Ground for the transmission line Ground for concentration control Handle for moving Handle for moving 635 Handle for moving 1350 Service panel Example of Notes Handle for moving ✻1507 1 371 Air intake ✻ 1423 920 1 • • • Refrigerant GAS pipe connction ø15.88 (5/8")Flare 2 • • • Refrigerant LIQUID pipe connection ø 9.52 (3/8")Flare ✻1 • • • Indication of STOP VALVE connection location. 23 2 Front piping cover Piping Knock-Out Hole Details 11 55 92 23 19 71 Rear piping cover Bottom piping hole (Knock-Out) 219 40 Power supply wiring hole (2-ø27Knock-Out) Rear trunking hole (Knock-Out) 73 63 63 ø92 73 23 27 92 73 63 27 65 23 92 45 40 55 75 ø 92 Front piping hole (Knock-Out) Right trunking hole (Knock-Out) 81 45 55 Front trunking hole 40 (Knock-Out) Power supply wiring hole (2-ø27Knock-Out) Right piping hole (Knock-Out) 30 ø92 27 Power supply wiring hole (2-ø27Knock-Out) 71 92 65 Rear piping hole (Knock-Out) 220 145 145 145 Drain hole 5-ø33 OUTDOOR UNIT Specifications & External Dimensions Y SERIES R410A Specifications Model name kW (*1) kcal/h (*2) BTU/h (*1) Capacity kW A 6.14 10.3/9.8/9.4 3.65 Compressor Power source Power input Current COP Heat exchanger type Type Starting method Motor output (kW) Type ✕ Quantity PUHY-P200YGM-A PUY-P200YGM-A Cooling Heating 22.4 25.0 20,000 – 76,400 85,300 Fan Airflow rate PUHY-P250YGM-A PUY-P250YGM-A Cooling Heating 28.0 31.5 25,000 – 95,500 107,500 5.98 10.0/9.5/9.2 4.18 4.7 m3/min L/s cfm Protection Motor output (kW) High pressure protection Inverter circuit Compressor/fan Gas side Refrigerant piping diameter mm(in.) Liquid side Refrigerant type Noise level (dB) (A-characteristic value) (*3) External finish kg(lbs) Net weight Total capacity Indoor unit Model/Quantity Height (H) External dimension mm(in.) Width (W) Depth (D) W.B. Indoor Temp. range of D.B. Outdoor cooling D.B Indoor Temp. range of W.B. Outdoor heating φ19.05(φ3/4") Brazed φ9.52(φ3/8") Flare 56 218(481) Models P20~P250/1~13 PUHY-P300YGM-A PUHY-P350YGM-A PUHY-P400YGM-A PUY-P300YGM-A PUY-P350YGM-A Cooling Heating Cooling Heating Cooling Heating 33.5 37.5 40.0 45.0 45.0 50.0 30,000 – 35,000 – 40,000 – 114,300 128,000 136,500 153,500 153,500 170,600 3N ~ 380/400/415V 50/60Hz 7.72 7.62 9.57 9.1 11.39 11.02 13.42 12.43 13.0/12.3/11.9 12.8/12.2/11.7 16.1/15.3/14.7 15.3/14.5/14.0 19.2/18.2/17.6 18.6/17.6/17.0 22.6/21.5/20.7 20.9/19.9/19.2 3.63 4.13 3.50 4.12 3.51 4.08 3.35 4.02 Salt Ptotected Fin Inverter scroll hermetic compressor Inverter 6.7 9.7 8.0 9.6 Propeller fan ✕ 1 240 200 4,000 3,333 8,476 7,063 0.64 0.38 High pressure switch 4.15MPa (601 psi) Over-voltage and over-current protection for AC bus, Over-heat protection Over-heat protection/Thermal switch φ22.2(φ7/8") Brazed φ28.58(φ1-1/8") Brazed φ12.7(φ1/2") Flare φ12.7(φ1/2") Flare φ9.52(φ3/8") Flare (φ12.7(φ1/2") for over 90m) φ9.52(φ3/8") Flare (φ12.7(φ1/2") for over 40m) R410A 60 61 57 59 Pre-coated galvanized sheets + powder coating (for-BS type) 233(514) 275(607) 233(514) 233(514) 50~130% of outdoor unit capacity Models P20~P250/1~20 Models P20~P250/1~22 Models P20~P250/1~16 Models P20~P250/1~19 1840(72-1/2") 990(39") 1290(50-13/16") 840(33-1/8") 15~24˚C (59~75˚F) -5~43˚C (23~109˚F) 0~43˚C (32~109˚F)(When the Outdoor is at a position lower than the Indoors) 15~27˚C (59~81˚F) -20~15.5˚C (-4~60˚F) PUHY-P450YGM-A Heating Cooling 50.0 56.0 45,000 – 170,600 191,100 PUHY-P550YGM-A PUHY-P600YGM-A PUHY-P650YGM-A Cooling Heating Cooling Heating Cooling Heating 63.0 67.0 67.4 75.0 73.0 81.5 55,000 – 60,000 – 65,000 – 215,000 228,600 230,000 255,900 249,100 278,100 Power source 3N ~ 380/400/415V 50/60Hz kW Power input 13.61 13.86 15.59 15.89 17.08 16.37 17.59 17.73 19.65 19.82 A Current 22.9/21.8/21.0 23.3/22.2/21.4 26.3/25.0/24.0 26.8/25.4/24.5 28.8/27.3/26.4 27.6/26.2/25.3 29.6/28.2/27.1 29.9/28.4/27.4 33.1/31.5/30.3 33.4/31.7/30.6 3.67 COP 4.04 3.59 3.96 3.69 4.09 3.83 4.23 3.72 4.11 Salt Protected Fin Heat exchanger type Inverter scroll hermetic compressor + Scroll hermetic Type Inverter + Direct Starting method 6.8 + 5.3 8.2 + 5.3 9.3 + 5.3 10.1 + 5.3 10.9 + 5.3 Motor output (kW) Type ✕ Quantity Propeller fan ✕ 2 m3/min 400 L/s 6,667 Airflow rate cfm 14,126 0.38 ✕ 2 Motor output (kW) High pressure switch 4.15MPa (601 psi) High pressure protection Over-current protection for AC bus, Over-heat protection Inverter circuit Over-heat protection/Thermal switch Compressor/fan Gas side φ28.58(φ1-1/8") Brazed Refrigerant piping diameter φ15.88(φ5/8") Flare mm(in.) Liquid side R410A Refrigerant type 60/61 (50Hz/60Hz) 61/62 (50Hz/60Hz) 62/62.5 (50Hz/60Hz) Noise level (dB) (A-characteristic value) (*3) Pre-coated galvanized sheets + powder coating (for-BS type) External finish kg(lbs) 455(1004) 455(1004) 455(1004) 455(1004) 455(1004) Net weight Total capacity 50~130% of outdoor unit capacity Indoor unit Model/Quantity Models P20~P250/1~24 Models P20~P250/1~24 Models P20~P250/1~24 Models P20~P250/1~32 Models P20~P250/1~32 Height (H) 1840(72-1/2") 1990(78-3/8") External dimension mm(in.) Width (W) Depth (D) 840(33-1/8") Indoor W.B. 15~24˚C (59~75˚F) Temp. range of Outdoor D.B. -5~43˚C (23~109˚F) 0~43˚C (32~109˚F)(When the Outdoor is at a position lower than the Indoors) cooling Indoor D.B 15~27˚C (59~81˚F) Temp. range of Outdoor W.B. -20~15.5˚C (-4~60˚F) Note: 1. Cooling/heating capacity indicates the maximum value at operation under the following condition. *1 (JIS Standard: JIS B8615-1) Cooling 27˚C(81˚F)DB/19˚C(66.2˚F)WB Outdoor: 35˚C(95˚F)DB *2 Cooling Indoor: 27˚C(81˚F)DB/19.5˚C(67.1˚F)WB Outdoor: 35˚C(95˚F)DB *3 It is measured in anechoic room. Heating Indoor: 20˚C(68˚F)DB Outdoor: 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB Pipe length: 5m(16-3/8Ft) Height difference: 0m Pipe length: 7.5m(24-9/16Ft) Height difference: 0m Model name Capacity kW (*1) kcal/h (*2) BTU/h (*1) PUHY-P500YGM-A Cooling Heating 56.0 63.0 50,000 – 191,100 215,000 Compressor Fan Protection External Dimensions 16 840 65 160 768 16 70 166 20 553 Y 80 57 A Conn. pipe(Gas) 200: ø19.05 250: ø22.2 300: ø22.2 350: ø28.58 2X2-14X20 0val hole ø62 Knockout hole (Mounting hole) Changeable to ø27,ø33 by using attached conduit mounting plate 80 Knockout hole 900(mounting pitch) 45 Air outlet Cross section X – X 45 990 Top view 265 Conn. pipe(Liquid) 200: ø9.52 250: ø9.52 300: ø9.52 350: ø12.7 Unit : mm 877 ø27 Knockout hole Y 845(mounting pitch) PUHY-P200,250,300,350YGM-A PUY-P200,250,300,350YGM-A 494 A 132 136 136 146 ø53 1840 Air inlet 135 80 40 1575 Knockout hole ø27 Knockout hole Service panel Refrig. service valve (Liquid) 67 160 X 37 117 117 Left side view 37 100 83 Knockout hole Refrig. service 67 207 valve(Gas) Knockout hole Front view 11 78 235 150 44 X 280 Note1.Use the opening at the bottom of the unit when running the power supply line from the front or from the side of the unit. Note2.Please refer to (2/2) for information regarding necessary spacing around the unit and foundation work. Air inlet 5 Cross section Y – Y 134 100 12 • Refrigerant (Gas) conn. pipe......1 pc. (P200type:Packaged in the accessory kit) (P250,P300,P350type:Already installed on the unit) • Packing for conn. pipe................1 pc. (P200type:Not attached) (P250,P300,P350type:Attached near the ball valve) • Conduit mouting plate ø33, ø27..............................1 pc.Each • Tapping screw M4......................2 pcs. 10 90 Model 200 250 300 350 207 67 12 OUTDOOR UNIT Specifications & External Dimensions Y SERIES R410A External Dimensions PUHY-P400YGM-A Unit : mm 840 Y 503 65 160 1068 Cross section X – Conn. pipe(Gas) ø28.58 80 ø62 Knockout hole to ø46,ø53 by using X Changeable attached conduit mounting plate Conn. pipe(Liquid) ø12.7 16 20 70 166 80 57 145 Knockout hole 877 ø27 Knockout hole Y 845(mounting pitch) 16 644 2X2-14X20 Oval hole (Mounting hole) 45 1200(mounting pitch) 45 1290 Top view ø53 265 Air outlet Air inlet Knockout hole • Refrigerant (Gas) conn. pipe......1 pc. (Already installed on the unit) • Packing for conn. pipe................1 pc. (Attached near the ball valve) • Conduit mouting plate ø53, ø46.............................1 pc.Each • Tapping screw M4.....................2 pcs. 135 Service panel Refrig. service valve (Liquid) X 40 67 160 X 235 150 100 Knockout hole 37 115 115 37 Left side view Refrig. service valve(Gas) 83 68 355 Knockout hole 11 78 10 89 Note1.Use the opening at the bottom of the unit when running the power supply line from the front or from the side of the unit. Note2.Please refer to (2/2) for information regarding necessary spacing around the unit and foundation work. 134 100 44 80 ø27 Knockout hole 1575 Cross section Y – Y 1840 Air inlet 5 280 12 355 68 Front view PUHY-P450,500,550,600,650YGM-A 16 1000 Y Y 768 Conn. pipe(Liquid) ø15.88 80 ø62 Knockout hole 3X2-14X20 Oval hole Changeable to ø46,ø53 by using (Mounting hole) attached conduit mounting plate 16 20 70 162 80 65 160 Conn. pipe(Gas) ø28.58 553 ø27 Knockout hole 57 145 840 Y Knockout hole 845(mounting pitch) Y 877 494 45 950(mounting pitch) 950(mounting pitch) 45 1990 Cross section X – X Top view ø53 265 Air outlet Air inlet 13 40 Service panel Refrig. service valve (Liquid) X 67 160 X 115 115 Left side view 37 100 Refrig. service valve(Gas) 83 68 205 Knockout hole Front view 11 78 Knockout hole 37 235 89 134 100 44 80 10 Note1.Use the opening at the bottom of the unit when running the power supply line from the front or from the side of the unit. Note2.Please refer to (2/2) for information regarding necessary spacing around the unit and foundation work. 135 ø27 Knockout hole 1575 Knockout hole • Refrigerant (Gas) conn. pipe....1 pc. (Already installed on the unit) • Packing for conn. pipe......1 pc. (Attached near the ball valve) • Conduit mouting plate ø53, ø46......1 pc.Each • Tapping screw M4...2 pcs. 150 Cross section Y – Y 1840 Air inlet 5 280 12 205 68 OUTDOOR UNIT Specifications & External Dimensions Y SERIES R410A Specifications PUHY-P700YSGM-A Model name Capacity kW (*1) kcal/h (*2) BTU/h (*1) Compressor Power source Power input kW Current A COP Composing unit model name Heat exchanger type Type Starting method Motor output (kW) Type ✕ Quantity Fan Airflow rate m3/min L/s cfm Protection Motor output (kW) High pressure protection Inverter circuit Heating 88.0 – 300,300 21.7 36.6/34.8/33.5 21.83 Total capacity Model/Quantity Height (H) External dimension Width (W) (mm(in.)) Depth (D) Indoor W.B. Temp. range of cooling Outdoor D.B. Indoor D.B Temp. range of heating Outdoor W.B. 36.8/35.0/33.7 4.03 3.61 PUHY-P700YGM-A (Compressor unit) Current COP kW (*1) kcal/h (*2) BTU/h (*1) 0.64 High pressure switch 4.15MPa (601 psi) Over-voltage and over-current protection for AC bus, Over-heat protection Over-heat protection/Thermal switch – – Propeller fan ✕ 1 240 4,000 8,476 0.64 – – Thermal switch R410A – PUHN-P01YGM-A (Heat exchanger unit) – – – Propeller fan ✕ 1 240 4,000 8,476 0.64 – – Thermal switch 0.64 High pressure switch 4.15MPa (601 psi) Over-voltage and over-current protection for AC bus, Over-heat protection Over-heat protection/Thermal switch φ34.93(φ1-3/8") Brazed φ28.58(φ1-1/8") Flange / φ28.58(φ1-1/8") Brazed φ19.05(φ3/4") Brazed + Flare φ12.7(φ1/2") Flare / φ12.7(φ1/2") Brazed – R410A 62 63 Pre-coated galvanized sheets + powder coating (for-BS type) 155(342) 430(948) 50~130% of outdoor unit capacity 430(948) Models P20~P250/1~34 155(342) Models P20~P250/1~34 1840(72-1/2") 1690(66-9/16") 990(39") 1690(66-9/16") 840(33-1/8") 15~24˚C (59~75˚F) -5~43˚C (23~109˚F) 0~43˚C (32~109˚F)(When the Outdoor is at a position lower than the Indoors) 15~27˚C (59~81˚F) -20~15.5˚C (-4~60˚F) 990(39") Cooling 90.0 80,000 Heating 100.0 – 341,200 307,100 3N ~ 380/400/415V 50/60Hz kW A Compressor Fan m3/min L/s cfm Protection Motor output (kW) High pressure protection Inverter circuit Compressor/fan Gas side (main)(mm(in.)) Gas side (between Comp unit and HEX unit)(mm(in.) Liquid side (main)(mm(in.)) Liquid side (between Comp unit and HEX unit)(mm(in.)) Refrigerant type Noise level (dB) Set (A-characteristic value) (*3) External finish Net weight kg(lbs) Refrigerant piping diameter Total capacity Model/Quantity Height (H) External dimension Width (W) (mm(in.)) Depth (D) Indoor W.B. Temp. range of cooling Outdoor D.B. Indoor D.B Temp. range of heating Outdoor W.B. 26.75 45.1/42.9/41.3 3.36 26.9 45.4/43.1/41.5 PUHY-P800YGM-A (Compressor unit) PUHN-P01YGM-A (Heat exchanger unit) 3.72 Salt Protected Fin Inverter scroll hermetic compressor ✕ 2 Inverter 10.1 + 10.1 Propeller fan ✕ 1 – – – Propeller fan ✕ 1 240 240 4,000 8,476 0.64 High pressure switch 4.15MPa (601 psi) Over-voltage and over-current protection for AC bus, Over-heat protection Over-heat protection/Thermal switch φ34.93(φ1-3/8") Brazed φ28.58(φ1-1/8") Flange / φ28.58(φ1-1/8") Brazed φ19.05(φ3/4") Brazed + Flare φ12.7(φ1/2") Flare / φ12.7(φ1/2") Brazed 4,000 8,476 0.64 – – Thermal switch – R410A 64 Pre-coated galvanized sheets + powder coating (for-BS type) 155(342) 430(948) 50~130% of outdoor unit capacity Models P20~P250/1~34 1840(72-1/2") Indoor unit Note: 25.37 42.8/40.6/39.2 3.72 PUHY-P800YSGM-A Composing unit model name Heat exchanger type Type Starting method Motor output (kW) Type ✕ Quantity Airflow rate 24.9 42.0/39.9/38.4 3.37 Inverter scroll hermetic compressor ✕ 2 Inverter 9.4 + 9.4 Propeller fan ✕ 1 240 4,000 8,476 – Model name Power source Power input 75,000 286,600 Heating 94.5 – 322,400 PUHN-P01YGM-A (Heat exchanger unit) PUHY-P750YGM-A (Compressor unit) Salt Protected Fin Inverter scroll hermetic compressor ✕ 2 Inverter 8.6 + 8.6 Propeller fan ✕ 1 240 4,000 8,476 Indoor unit Capacity Cooling 84.0 3N ~ 380/400/415V 50/60Hz Refrigerant piping diameter Compressor/fan Gas side (main)(mm(in.)) Gas side (between Comp unit and HEX unit)(mm(in.) Liquid side (main)(mm(in.)) Liquid side (between Comp unit and HEX unit)(mm(in.)) Refrigerant type Noise level (dB) Set (A-characteristic value) (*3) External finish Net weight kg(lbs) PUHY-P750YSGM-A Cooling 78.4 70,000 267,500 990(39") 840(33-1/8") 15~24˚C (59~75˚F) -5~43˚C (23~109˚F) 0~43˚C (32~109˚F)(When the Outdoor is at a position lower than the Indoors) 15~27˚C (59~81˚F) -20~15.5˚C (-4~60˚F) 1690(66-9/16") 1. Cooling/heating capacity indicates the maximum value at operation under the following condition. *1 (JIS Standard: JIS B8615-1) Cooling 27˚C(81˚F)DB/19˚C(66.2˚F)WB Outdoor: 35˚C(95˚F)DB *2 Cooling Indoor: 27˚C(81˚F)DB/19.5˚C(67.1˚F)WB Outdoor: 35˚C(95˚F)DB Heating Indoor: 20˚C(68˚F)DB Outdoor: 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB Pipe length: 5m(16-3/8Ft) Height difference: 0m Pipe length: 7.5m(24-9/16Ft) Height difference: 0m *3 It is measured in anechoic room. 14 OUTDOOR UNIT Specifications & External Dimensions Y SERIES R410A Refrig.service valve (Liquid pipe to HEX unit) ø12.7 124 Refrig.service valve (Gas pipe to indoor unit) ø27 Knockout hole 159 161 107 840 ø75 Knockout hole Changeable to ø62 by using attached conduit mounting plate Refrig.service valve (Gas pipe to HEX unit) ø28.58 877 Unit : mm Refrig.service valve (Liquid pipe to indoor unit) 845(mounting pitch) Knockout hole 3 X 2 – 14 X 20 Oval hole 45 800(mounting pitch) 800(mounting pitch) 16 PUHY-P700,750,800YGM-A 16 External Dimensions 45 1690 (Mounting hole) Cross section X – X Top view Service panel 1840 Air inlet Knockout hole Air inlet 1575 • Refrigerant conn. pipe with flange (to indoor unit:Gas)....1 pc. (Already installed on the unit) • Refrigerant conn. pipe with flange (to HEX unit:Gas).......1 pc. (Already installed on the unit) • Packing for conn. pipe with flange (to indoor unit:Gas)....1 pc. (Attached near ball valve) • Packing for conn. pipe with flange (to HEX unit:Gas)......1 pc. (Attached near ball valve) • Conduit mouting plate ø62...........................1 pc. • Tapping screw µ4.....2 pcs. 265 Air outlet Service panel ø27 Knockout hole 175 11 78 3 12 241 117 83 Knockout hole 37 254 88 Conn. pipe(Gas) ø34.93 840 845(mounting pitch) Note1.Use the opening at the bottom of the unit when running the power supply line from the front or from the side of the unit. Note2.Please refer to (2/2) for information regarding necessary space around the unit and foundation work. 120 60 ø27hole+rubber bush (Bottom of controlbox) 2x2-14x20 Oval hole (Mounting hole) Cross section x-x 16 82 ø27hole+rubber bush (Bottom of controlbox) Conn. pipe(Liquid) ø19.05 Front view 16 Left side view PUHN-P01YGM-A 877 175 280 134 100 10 89 37 X X Knockout hole 900(mounting pitch) 45 45 990 Air outlet Air outlet 265 Top view 1575 Air inlet Air inlet 117 37 67 80 207 134 115 157 207 67 Knockout hole Left side view 80 50 40 250 45 11 78 165 10 90 Refrig. service valve (Liquid pipe to compressor unit) ø12.7 37 117 Air inlet Right side view Front view 877 2690 840 990 Air outlet HEX unit 10 1690 Compressor unit 265 PUHY-P700,750,800YSGM-A 70 Air inlet Knockout hole x x Refrig. service valve (Gas pipe to compressor unit) ø28.58 Air inlet 1840 Air inlet Air inlet 1575 1840 Air inlet Gas pipe used to connect compressor unit and HEX unit Left side view 15 Liquid pipe used to connect compressor unit and HEX unit Conn.pipe(Gas) ø34.93 Front view Conn.pipe(Liquid) ø19.05 11 135 Note1.Use the opening at the bottom of the unit when running the power supply line from the front or from the side of the unit. Note2.Please refer to (2/2) for information regarding necessary space around the unit and foundation work. OUTDOOR UNIT Specifications & External Dimensions Y SERIES R410A Specifications PUHY-P850YSGM-A Model name Capacity (*1) kW Btu/h(*1) kcal/h(*2) Power input kW Current input A COP Power source Heating 96.0 327,500 108.0 368,500 85,000 25.28 – 27.47 42.6/40.5/39.0 3.80 46.3/44.0/42.4 3.93 PUHY-P450YMM-A PUHY-P400YSM-A 9.4 + 5.3 / 8.5 + 5.3 Propeller fan ✕ 2 8.5 + 5.3 / 8.5 + 5.3 PUHY-P900YSGM-A Heating Cooling 113.0 344,600 90,000 385,500 – 29.10 108.0 368,500 26.71 45.0/42.8/41.2 49.1/46.6/44.9 3.78 3.88 Motor output (kW) Type ✕ Quantity Fan m3/min L/s cfm Airflow rate Protection Motor output (kW) High pressure protection Inverter scroll hermetic comp. + Scroll hermetic comp. Inverter + Direct 8.5 + 5.3 / 8.5 + 5.3 10.3 + 5.3 / 9.6 + 5.3 Propeller fan ✕ 2 400 400 6,667 14,126 0.38 ✕ 2 30.42 51.3/48.7/47.0 49.3/46.8/45.1 3.69 3.93 PUHY-P550YMM-A PUHY-P400YSM-A 11.2 + 5.3 / 10.9 + 5.3 Propeller fan ✕ 2 8.5 + 5.3 / 8.5 + 5.3 6,667 400 6,667 14,126 0.38 ✕ 2 14,126 0.38 ✕ 2 6,667 400 6,667 14,126 0.38 ✕ 2 14,126 0.38 ✕ 2 Propeller fan ✕ 2 400 6,667 14,126 0.38 ✕ 2 φ41.28(φ1-5/8") Brazed φ28.58(φ1-1/8") Brazed φ19.05(φ3/4") Brazed φ15.88(φ5/8") Flare φ9.52(φ3/8") Flare R410A 63/64 63/64 63/64 Pre-coated galvanized sheets + powder coating (for-BS type) 460 (1015) 458 (1010) 460 (1015) 458 (1010) 458 (1010) PUHY-P1000YSGM-A Model name Capacity (*1) kW Btu/h(*1) kcal/h(*2) Power input kW Current input A COP Power source Composing unit model name Heat exchanger type Type Starting method Motor output (kW) Type ✕ Quantity Compressor Fan Protection Motor output (kW) High pressure protection Inverter circuit Compressor/fan Gas side (main)(mm(in.)) Gas side (between unit and distributor)(mm(in.)) Liquid side (main)(mm(in.)) Liquid side (between unit and distributor)(mm(in.)) Oil balance pipe(mm(in.)) Refrigerant type Noise level (dB) Set (A-characteristic value) (*3) External finish Net weight kg (lbs.) Refrigerant piping diameter Total capacity Model / Quantity Height (H) External dimension Width (W) (mm(in.)) Depth (D) W.B. Indoor Temp. range of cooling Outdoor D.B. D.B. Indoor Temp. range of heating Outdoor W.B. PUHY-P1050YSGM-A Cooling 113.0 385,500 100,000 Heating 127.0 433,300 – 31.11 52.5/49.8/48.0 32.68 55.1/52.4/50.5 3.63 3.89 Cooling Heating 132.0 450,300 – 34.24 57.8/54.9/52.9 3.86 118.0 402,600 105,000 33.48 56.5/53.6/51.7 3.52 3-phase 4-wire 380/400/415V 50/60Hz PUHY-P400YSM-A PUHY-P650YMM-A Salt-resistant cross fin & copper tube Inverter scroll hermetic comp. + Scroll hermetic comp. Inverter + Direct PUHY-P600YMM-A m3/min L/s cfm 460 (1015) 50~130% of outdoor unit capacity P20~P250 / 1~42 1840 (72-1/2") 1990 (78-3/8") 840 (33-1/8") 15~24˚C (59~75˚F) -5~43˚C (23~109˚F) 0~43˚C (32~109˚F)(When the Outdoor is at a position lower than the Indoors) 15~27˚C (59~81˚F) -20~15.5˚C (-4~60˚F) Total capacity Model / Quantity Height (H) External dimension Width (W) (mm(in.)) Depth (D) W.B. Indoor Temp. range of cooling Outdoor D.B. D.B. Indoor Temp. range of heating Outdoor W.B. Note: Propeller fan ✕ 2 400 Propeller fan ✕ 2 Refrigerant piping diameter Gas side (main)(mm(in.)) Gas side (between unit and distributor)(mm(in.)) Liquid side (main)(mm(in.)) Liquid side (between unit and distributor)(mm(in.)) Oil balance pipe(mm(in.)) Refrigerant type Noise level (dB) Set (A-characteristic value) (*3) External finish Net weight kg (lbs.) Indoor unit 407,700 – High pressure switch 4.15MPa (601 psi) High pressure switch 4.15MPa (601 psi) High pressure switch 4.15MPa (601 psi) Over-voltage and over-current protection for AC bus, Over-heat protection Over-voltage and over-current protection for AC bus, Over-heat protection Over-voltage and over-current protection for AC bus, Over-heat protection Over-heat protection/Thermal switch Over-heat protection/Thermal switch Over-heat protection/Thermal switch Inverter circuit Compressor/fan Airflow rate Heating 119.5 95,000 29.23 PUHY-P500YMM-A PUHY-P400YSM-A Salt-resistant cross fin & copper tube Type Starting method Indoor unit PUHY-P950YSGM-A Cooling 101.0 3-phase 4-wire 380/400/415V 50/60Hz Composing unit model name Heat exchanger type Compressor Cooling 11.6 + 5.3 / 11.6 + 5.3 Propeller fan ✕ 2 400 6,667 14,126 0.38 ✕ 2 8.5 + 5.3 / 8.5 + 5.3 Propeller fan ✕ 2 400 6,667 14,126 0.38 ✕ 2 PUHY-P400YSM-A 11.6 + 5.3 / 11.6 + 5.3 Propeller fan ✕ 2 400 6,667 14,126 0.38 ✕ 2 8.5 + 5.3 / 8.5 + 5.3 Propeller fan ✕ 2 400 6,667 14,126 0.38 ✕ 2 High pressure switch 4.15MPa (601 psi) High pressure switch 4.15MPa (601 psi) Over-voltage and over-current protection for AC bus, Over-heat protection Over-voltage and over-current protection for AC bus, Over-heat protection Over-heat protection/Thermal switch Over-heat protection/Thermal switch φ41.28(φ1-5/8") Brazed φ28.58(φ1-1/8") Brazed φ19.05(φ3/4") Brazed φ15.88(φ5/8") Flare φ9.52(φ3/8") Flare R410A 63/64 458 (1010) 63.5/64.5 Pre-coated galvanized sheets + powder coating (for-BS type) 460 (1015) 458 (1010) 460 (1015) 50~130% of outdoor unit capacity P20~P250 / 1~42 1840 (72-1/2") 1990 (78-3/8") 840 (33-1/8") 15~24˚C (59~75˚F) -5~43˚C (23~109˚F) 0~43˚C (32~109˚F)(When the Outdoor is at a position lower than the Indoors) 15~27˚C (59~81˚F) -20~15.5˚C (-4~60˚F) 1. Cooling/heating capacity indicates the maximum value at operation under the following condition. *1 (JIS Standard: JIS B8615-1) Cooling 27˚C(81˚F)DB/19˚C(66.2˚F)WB Outdoor: 35˚C(95˚F)DB *2 Cooling Indoor: 27˚C(81˚F)DB/19.5˚C(67.1˚F)WB Outdoor: 35˚C(95˚F)DB Heating Indoor: 20˚C(68˚F)DB Outdoor: 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB Pipe length: 5m(16-3/8Ft) Height difference: 0m Pipe length: 7.5m(24-9/16Ft) Height difference: 0m *3 It is measured in anechoic room. 16 OUTDOOR UNIT Specifications & External Dimensions Y SERIES R410A Specifications PUHY-P1100YSGM-A Model name Capacity (*1) kW Btu/h(*1) kcal/h(*2) Power input kW Current input A COP Heating 140.0 423,000 110,000 477,600 – 36.39 61.4/58.3/56.2 36.93 62.3/59.2/57.0 39.96 67.4/64.0/61.7 3.41 3.79 3.25 Power source Composing unit model name Heat exchanger type PUHY-P450YMM-A Compressor Fan m3/min L/s cfm Airflow rate Protection Motor output (kW) High pressure protection Inverter circuit Compressor/fan 9.4 + 5.3 / 8.5 + 5.3 Propeller fan ✕ 2 11.6 + 5.3 / 11.6 + 5.3 Propeller fan ✕ 2 400 400 6,667 6,667 14,126 – 38.46 64.9/61.6/59.4 3.77 PUHY-P650YSM-A 10.3 + 5.3 / 9.6 + 5.3 Propeller fan ✕ 2 11.6 + 5.3 / 11.6 + 5.3 Propeller fan ✕ 2 400 400 6,667 6,667 14,126 14,126 0.38 ✕ 2 0.38 ✕ 2 High pressure switch 4.15MPa (601 psi) 14,126 0.38 ✕ 2 0.38 ✕ 2 High pressure switch 4.15MPa (601 psi) Refrigerant piping diameter Over-voltage and over-current protection for AC bus, Over-heat protection Over-voltage and over-current protection for AC bus, Over-heat protection Over-heat protection/Thermal switch Over-heat protection/Thermal switch φ41.28(φ1-5/8") Brazed φ28.58(φ1-1/8") Brazed φ19.05(φ3/4") Brazed φ15.88(φ5/8") Flare φ9.52(φ3/8") Flare R410A 64/65 64/65 Pre-coated galvanized sheets + powder coating (for-BS type) 460 (1015) 458 (1010) 458 (1010) 1840 (72-1/2") 1990 (78-3/8") 840 (33-1/8") 15~24˚C (59~75˚F) -5~43˚C (23~109˚F) 0~43˚C (32~109˚F)(When the Outdoor is at a position lower than the Indoors) 15~27˚C (59~81˚F) -20~15.5˚C (-4~60˚F) PUHY-P1200YSGM-A Model name Capacity (*1) kW Btu/h(*1) kcal/h(*2) kW A PUHY-P1250YSGM-A Cooling 136.0 464,000 120,000 44.40 Heating 150.0 511,700 – 39.73 74.9/71.2/68.6 3.06 67.0/63.7/61.4 3.78 Cooling 140.0 Heating 156.5 533,900 – 42.63 71.9/68.3/65.8 3.67 477,600 125,000 47.56 80.2/76.2/73.5 2.94 3-phase 4-wire 380/400/415V 50/60Hz PUHY-P650YSM-A PUHY-P600YMM-A PUHY-P550YMM-A PUHY-P650YSM-A Salt-resistant cross fin & copper tube Inverter scroll hermetic comp. + Scroll hermetic comp. Inverter + Direct Compressor Power input Current input COP Power source Composing unit model name Heat exchanger type Type Starting method Motor output (kW) Type ✕ Quantity 460 (1015) 50~130% of outdoor unit capacity P20~P250 / 1~42 Total capacity Model / Quantity Height (H) External dimension Width (W) (mm(in.)) Depth (D) W.B. Indoor Temp. range of cooling Outdoor D.B. D.B. Indoor Temp. range of heating Outdoor W.B. Indoor unit Fan m3/min L/s cfm Protection Motor output (kW) High pressure protection Inverter circuit Compressor/fan Gas side (main)(mm(in.)) Gas side (between unit and distributor)(mm(in.)) Liquid side (main)(mm(in.)) Liquid side (between unit and distributor)(mm(in.)) Oil balance pipe(mm(in.)) Refrigerant type Noise level (dB) Set (A-characteristic value) (*3) External finish Net weight kg (lbs.) Refrigerant piping diameter Total capacity Model / Quantity Height (H) External dimension Width (W) (mm(in.)) Depth (D) W.B. Indoor Temp. range of cooling Outdoor D.B. D.B. Indoor Temp. range of heating Outdoor W.B. 17 145.0 494,700 115,000 Inverter + Direct Gas side (main)(mm(in.)) Gas side (between unit and distributor)(mm(in.)) Liquid side (main)(mm(in.)) Liquid side (between unit and distributor)(mm(in.)) Oil balance pipe(mm(in.)) Refrigerant type Noise level (dB) Set (A-characteristic value) (*3) External finish Net weight kg (lbs.) Note: Heating 130.0 443,500 Salt-resistant cross fin & copper tube Inverter scroll hermetic comp. + Scroll hermetic comp. Motor output (kW) Type ✕ Quantity Indoor unit Cooling 3-phase 4-wire 380/400/415V 50/60Hz PUHY-P650YSM-A PUHY-P500YMM-A Type Starting method Airflow rate PUHY-P1150YSGM-A Cooling 124.0 11.2 + 5.3 / 10.9 + 5.3 Propeller fan ✕ 2 400 6,667 14,126 0.38 ✕ 2 11.6 + 5.3 / 11.6 + 5.3 Propeller fan ✕ 2 400 6,667 14,126 0.38 ✕ 2 11.6 + 5.3 / 11.6 + 5.3 Propeller fan ✕ 2 400 6,667 14,126 0.38 ✕ 2 11.6 + 5.3 / 11.6 + 5.3 Propeller fan ✕ 2 400 6,667 14,126 0.38 ✕ 2 High pressure switch 4.15MPa (601 psi) High pressure switch 4.15MPa (601 psi) Over-voltage and over-current protection for AC bus, Over-heat protection Over-voltage and over-current protection for AC bus, Over-heat protection Over-heat protection/Thermal switch Over-heat protection/Thermal switch φ41.28(φ1-5/8") Brazed φ28.58(φ1-1/8") Brazed φ19.05(φ3/4") Brazed φ15.88(φ5/8") Flare φ9.52(φ3/8") Flare R410A 64/65 458 (1010) 65/65.5 Pre-coated galvanized sheets + powder coating (for-BS type) 460 (1015) 458 (1010) 460 (1015) 50~130% of outdoor unit capacity P20~P250 / 1~42 1840 (72-1/2") 1990 (78-3/8") 840 (33-1/8") 15~24˚C (59~75˚F) -5~43˚C (23~109˚F) 0~43˚C (32~109˚F)(When the Outdoor is at a position lower than the Indoors) 15~27˚C (59~81˚F) -20~15.5˚C (-4~60˚F) 1. Cooling/heating capacity indicates the maximum value at operation under the following condition. *1 (JIS Standard: JIS B8615-1) Cooling 27˚C(81˚F)DB/19˚C(66.2˚F)WB Outdoor: 35˚C(95˚F)DB *2 Cooling Indoor: 27˚C(81˚F)DB/19.5˚C(67.1˚F)WB Outdoor: 35˚C(95˚F)DB Heating Indoor: 20˚C(68˚F)DB Outdoor: 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB Pipe length: 5m(16-3/8Ft) Height difference: 0m Pipe length: 7.5m(24-9/16Ft) Height difference: 0m *3 It is measured in anechoic room. OUTDOOR UNIT Specifications & External Dimensions Y SERIES R410A External Dimensions 1000 16 494 Y Y Y ø27 Knockout hole 70 65 160 16 80 76 57 45 ø62 Knockout hole Conn. pipe ø28.58 950(mounting pitch) 950(mounting pitch) 45 1990 80 768 Changeable to ø46,ø53 by using attached conduit mounting plate 3✕2–14✕20 Oval hole (Mounting hole) Cross section X–X Top view ø53 265 Air outlet 5 Air inlet Service panel 10 37 115 115 37 Left side view 280 X X 67 160 235 217 194 163 89 134 100 Knockout hole Refrig.service valve Knockout hole Refrig.service valve 100 68 Conn. pipe ø15.88 205 285 48 Service valve ø9.52 11 78 135 80 40 ø27 Knockout hole 1575 Knockout hole 205 68 Front view 1000 16 494 Refrig.service valve Y Y 840 Y Refrig.service valve Y ø27 Knockout hole 16 70 57 92 76 80 20 Knockout hole 845(mounting pitch) PUHY-P450,650YSM-A 1840 Air inlet • Refrigerant(Gas) conn.pipe....1pc. (Already installed on the unit) • Packing for conn.pipe....1pc. (Attached near the ball valve) • Conduit mounting plate ø53, ø46...1pc.Each • Tapping screw M4....2pcs. Note1.Use the opening at the bottom of the unit when running the power supply line from the front or from the side of the unit. Note2.Please refer to (2/2) for information regarding necessary spacing around the unit and foundation work. Note3.This unit is used in combination with a sub unit.(Refer to Drawing No.W656886 Outline Drawing of Outdoor Unit set) 553 12 Cross section Y–Y 877 145 20 Knockout hole 877 Refrig.service valve 840 Y 845(mounting pitch) Refrig.service valve 553 PUHY-P450,500,550, 600,650YMM-A 65 160 45 ø62 Knockout hole 768 950(mounting pitch) 950(mounting pitch) 45 1990 80 Changeable to ø46,ø53 by using attached conduit mounting plate 3✕2–14✕20 Oval hole (Mounting hole) Cross section X–X Top view 5 877 840 PUHY-P850,900,950, 1000,1050,1100,1150, 1200,1250YSGM-A Air inlet Knockout hole Air inlet ø27 Knockout hole ø41.28 1575 Service panel X X Conn.pipe ø28.58 67 160 115 115 37 100 Knockout hole 62 68 Knockout hole Left side view 1990 205 285 48 Service valve ø9.52 Conn.pipe ø15.88 68 Front view 10 1990 Main unit Air outlet 205 11 78 37 245 235 217 163 89 134 100 45 135 control wiring> 80 40 10 • Gas distributor....1pc. (Already installed on the unit) • Liquid distributor....1pc. • Packing for conn. pipe....1pc. (Attached near the gas distributor) • Conduit mounting plate ø53, ø46....1pc.Each • Tapping screw M4....2pcs. • Conn. pipe(Gas)....2pcs. Note1.Use the opening at the bottom of the unit when running the power supply line from the front or from the side of the unit. Note2.Please refer to (2/2) for information regarding necessary spacing around the unit and foundation work. Note3.This unit is used in combination with a main unit.(Refer to Drawing No.W656886 Outline Drawing of Outdoor Unit set) 1840 Cross section Y–Y 280 12 265 ø53 Air outlet Sub unit Air inlet Air inlet Distributor(Gas) f PUHY-P850YSGM-A PUHY-P900YSGM-A PUHY-P950YSGM-A PUHY-P1000YSGM-A PUHY-P1050YSGM-A PUHY-P1100YSGM-A PUHY-P1150YSGM-A PUHY-P1200YSGM-A PUHY-P1250YSGM-A PUHY-P450YMM-A PUHY-P500YMM-A PUHY-P550YMM-A PUHY-P600YMM-A PUHY-P650YMM-A PUHY-P450YMM-A PUHY-P500YMM-A PUHY-P550YMM-A PUHY-P600YMM-A PUHY-P650YSM-A PUHY-P400YSM-A Main unit Sub unit Indoor units~ Distributor Distributor~ Main unit Distributor~ Sub unit Oil balance pipe Liquid Gas Liquid Gas Liquid Gas a ø19.05 b c ø41.28 ø15.88 ø28.58 ø15.88 ø28.58 ø9.52 d e f g g e d c Left side view b Front view Distributor(Liquid) a Indoor units Note1.Pipe size is as show in the table on the left. 18 OUTDOOR UNIT Specifications & External Dimensions R2 SERIES R410A Specifications Model name Capacity kW (*1) kcal/h (*2) BTU/h (*1) Fan Airflow rate PURY-P250YGM-A Heating Cooling 31.5 28.0 – 25,000 107,500 95,500 PURY-P300YGM-A PURY-P350YGM-A PURY-P400YGM-A Heating Cooling Heating Cooling Heating Cooling 50.0 45.0 45.0 40.0 37.5 33.5 – 40,000 – 35,000 – 30,000 170,600 153,500 153,500 136,500 128,000 114,300 3N ~ 380/400/415V 50/60Hz 12.43 13.42 11.02 11.39 9.1 9.57 7.62 7.72 20.9/19.9/19.2 22.6/21.5/20.7 18.6/17.6/17.0 19.2/18.2/17.6 15.3/14.5/14.0 16.1/15.3/14.7 12.8/12.2/11.7 13.0/12.3/11.9 4.02 3.35 4.08 3.51 4.12 3.50 4.13 3.63 Salt Protected Fin Inverter scroll hermetic compressor Inverter 6.7 8.0 9.6 9.7 Propeller fan ✕ 1 240 200 4,000 3,333 8,476 7,063 0.64 0.38 High pressure switch 4.15MPa (601 psi) Over-voltage and over-current protection for AC bus, Over-heat protection Over-heat protection/Thermal switch φ28.58(φ1-1/8") brazed φ22.2(φ7/8") brazed φ19.05(φ3/4") brazed φ22.2(φ7/8") brazed R410A 57 59 60 61 Pre-coated galvanized sheets + powder coating (for-BS type) 251(554) 251(554) 251(554) 291(642) 50~150% of outdoor unit capacity Models P20~P250/1~16 Models P20~P250/1~16 Models P20~P250/1~20 Models P20~P250/1~24 1840(72-1/2") 1290(50-13/16") 990(39") 840(33-1/8") 15~24˚C (59~75˚F) -5~43˚C (23~109˚F) 0~43˚C (32~109˚F)(When the Outdoor is at a position lower than the Indoors) 15~27˚C (59~81˚F) -20~15.5˚C (-4~60˚F) 5.98 10.0/9.5/9.2 4.18 6.14 10.3/9.8/9.4 3.65 kW A Compressor Power source Power input Current COP Heat exchanger type Type Starting method Motor output (kW) Type ✕ Quantity PURY-P200YGM-A Heating Cooling 25.0 22.4 – 20,000 85,300 76,400 4.7 m3/min L/s cfm Protection device Motor output (kW) High pressure protection Inverter circuit Compressor/fan Refrigerant piping diameter Gas side (mm(in.)) Liquid side Refrigerant type Noise level (dB) (A-characteristic value) (*3) External finish Net weight kg (lbs) Total capacity Indoor unit Model/Quantity Height (H) External dimension (mm(in.)) Width (W) Depth (D) Temp. range of W.B. Indoor cooling D.B. Outdoor Temp. range of D.B Indoor heating W.B. Outdoor kW (*1) kcal/h (*2) BTU/h (*1) kW A Compressor Power source Power input Current COP Heat exchanger type Type Starting method Motor output (kW) Type ✕ Quantity Fan Airflow rate 56 236(521) Models P20~P250/1~15 PURY-P450YGM-A Cooling Heating 50.0 56.0 45,000 – 170,600 191,100 Model name Capacity φ19.05(φ3/4") brazed φ15.88(φ5/8") brazed m3/min L/s cfm Protection device Motor output (kW) High pressure protection Inverter circuit Compressor/fan Refrigerant piping diameter Gas side (mm(in.)) Liquid side Refrigerant type Noise level (dB) (A-characteristic value) (*3) External finish kg (lbs) Net weight Total capacity Indoor unit Model/Quantity Height (H) External dimension (mm(in.)) Width (W) Depth (D) Temp. range of W.B. Indoor cooling D.B. Outdoor Temp. range of D.B Indoor heating W.B. Outdoor PURY-P550YGM-A PURY-P600YGM-A Cooling Heating Cooling Heating 63.0 67.0 67.4 75.0 55,000 – 60,000 – 215,000 228,600 230,000 255,900 3N ~ 380/400/415V 50/60Hz 13.61 13.86 15.59 15.89 17.08 16.37 17.59 17.73 22.9/21.8/21.0 23.3/22.2/21.4 26.3/25.0/24.0 26.8/25.4/24.5 28.8/27.3/26.4 27.6/26.2/25.3 29.6/28.2/27.1 29.9/28.4/27.4 3.67 4.04 3.59 3.96 3.69 4.09 3.83 4.23 Salt Protected Fin Inverter scroll hermetic compressor Inverter 8.2 + 5.3 9.3 + 5.3 10.1 + 5.3 6.8 + 5.3 Propeller fan ✕ 1 Propeller fan ✕ 2 400 6,667 14,126 0.38 ✕ 2 High pressure switch 4.15MPa (601 psi) Over-voltage and over-current protection for AC bus, Over-heat protection Over-heat protection/Thermal switch φ28.58(φ1-1/8") brazed φ22.2(φ7/8") brazed φ28.58(φ1-1/8") brazed R410A 61/62 (50Hz/60Hz) 60/61 (50Hz/60Hz) Pre-coated galvanized sheets + powder coating (for-BS type) 481(1061) 481(1061) 481(1061) 481(1061) 50~150% of outdoor unit capacity Models P20~P250/1~24 Models P20~P250/1~24 Models P20~P250/1~24 Models P20~P250/1~32 1840(72-1/2") 1990(78-3/8") 840(33-1/8") 15~24˚C (59~75˚F) -5~43˚C (23~109˚F) 0~43˚C (32~109˚F)(When the Outdoor is at a position lower than the Indoors) 15~27˚C (59~81˚F) -20~15.5˚C (-4~60˚F) Note: 1. Cooling/heating capacity indicates the maximum value at operation *1 (JIS Standard: JIS B8615-1) Cooling 27˚C(81˚F)DB/19˚C(66.2˚F)WB Heating Indoor: 20˚C(68˚F)DB Pipe length: 7.5m(24-9/16Ft) PURY-P500YGM-A Cooling Heating 56.0 63.0 50,000 – 191,100 215,000 under the following condition. Outdoor: 35˚C(95˚F)DB *2 Cooling Indoor: 27˚C(81˚F)DB/19.5˚C(67.1˚F)WB Outdoor: 35˚C(95˚F)DB Outdoor: 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB Pipe length: 5m(16-3/8Ft) Height difference: 0m Height difference: 0m PURY-P650YGM-A Cooling Heating 73.0 81.5 65,000 – 249,100 278,100 19.65 33.1/31.5/30.3 3.72 19.82 33.4/31.7/30.6 4.11 10.9 + 5.3 62/62.5 (50Hz/60Hz) 481(1061) Models P20~P250/1~32 *3 It is measured in anechoic room. External Dimensions 494 840 553 20 65 160 2X2-14X20 0val hole 80 ø62 Knockout hole 768 Knockout hole 16 70 45 Changeable to ø27,ø33 by using attached conduit mounting plate Cross section X–X 900(bolt hole) 45 990 Plane view Air outlet 265 Conn. pipe (high pressure) 200:ø15.88 250:ø19.05 300:ø19.05 350:ø19.05 B 80 57 A Y Unit : mm 877 ø27 Knockout hole Y Conn. pipe (low pressure) 200:ø19.05 250:ø22.2 300:ø22.2 350:ø28.58 845(bolt hole) 16 PURY-P200,250,300,350YGM-A B 115 120 120 120 135 80 40 1840 1575 Knockout hole ø27 Knockout hole Service panel Refrig. service valve (high pressure) 67 160 X 37 117 117 37 Left side view Knockout hole Refrig. service 83 valve(low pressure) 100 67 207 Knockout hole Front view 11 78 235 15 X 184 19 [Accessories] • Refrigerant (high pressure) conn. pipe..............1pc. • Refrigerant (low pressure) conn. pipe................1pc. (The connecting pipe has been fixed with the unit) • Packing for conn. low pressure pipe..................1pc. (Attached near the ball valve) • Conduit mouting plate ø33, ø27............................Each 1pc. • Tapping screw M4.....................1pcs. Air inlet Air inlet 280 5 134 100 12 Cross section Y–Y 10 90 A 145 135 135 145 ø53 Model 200 250 300 350 207 67 OUTDOOR UNIT Specifications & External Dimensions R2 SERIES R410A External Dimensions PURY-P400YGM-A Unit : mm 503 65 160 1068 Conn. pipe (low pressure) ø28.58 80 Cross section X–X Conn. pipe (high pressure) ø22.2 16 20 81 70 80 57 145 840 Y Knockout hole 877 ø27 Knockout hole Y 845(bolt hole) 16 644 2X2-14X20 Oval hole ø62 Knockout hole Changeable to ø46,ø53 by using attached conduit mounting plate 45 1200(bolt hole) 45 1290 Plane view ø53 265 Air outlet Air inlet [Accessories] • Refrigerant (high pressure) conn. pipe........... 1pc. (The connecting pipe has been fixed with the unit) • Refrigerant (low pressure) conn. pipe............. 1pc. (The connecting pipe has been fixed with the unit) • Packing for conn. high pressure pipe.............. 1pc. (Attached near the ball valve) • Packing for conn. low pressure pipe............... 1pc. (Attached near the ball valve) • Conduit mouting plate ø53, ø46................... Each 1pc. • Tapping screw M4............ 2pcs. Knockout hole 135 Service panel Refrig. service valve (high pressure) 67 160 X 40 X 115 115 37 Knockout hole Left side view Knockout hole 11 78 235 Refrig. service 83 valve(low pressure) 100 355 68 10 37 184 89 280 15 80 ø27 Knockout hole 1575 Cross section Y–Y 1840 Air inlet 5 134 100 12 355 68 Front view PURY-P450,500,550,600,650YGM-A 1000 16 494 Y 65 160 Conn. pipe (high pressure) 450:ø22.2 500:ø22.2 550:ø28.58 600:ø28.58 650:ø28.58 80 ø62 Knockout hole Changeable to ø46,ø53 by using attached conduit mounting plate 3X2-14X20 Oval hole 45 950(bolt hole) 950(bolt hole) 45 1990 Cross section X–X Plane view Air outlet 265 768 ø53 Conn. pipe (low pressure) ø28.58 16 70 145 80 57 145 20 877 ø27 Knockout hole 840 Y Knockout hole 845(bolt hole) Y 553 Y 37 115 115 Left side view 37 Service panel X Refrig. service 90 valve(low pressure) 100 68 205 Knockout hole 11 78 150 44 235 Refrig. service valve (high pressure) 67 160 X Knockout hole 280 135 80 40 1575 Knockout hole ø27 Knockout hole 134 100 [Accessories] • Refrigerant (high pressure) conn. pipe.......... 1 pc. (The connecting pipe has been fixed with the unit) • Refrigerant (low pressure) conn. pipe............ 1 pc. (The connecting pipe has been fixed with the unit) • Packing for conn. high pressure pipe............. 1 pc. (Attached near the ball valve) • Packing for conn. low pressure pipe.............. 1 pc. (Attached near the ball valve) • Conduit mouting plate ø53, ø46..................... Each 1 pc. • Tapping screw M4.............. 2 pcs. Air inlet 89 Cross section Y–Y 1840 Air inlet 5 10 12 290 260 260 290 205 68 Front view 20 HEAT SOURCE UNIT Specifications & External Dimensions WY SERIES R410A Specifications PQHY-P200YGM-A Heating Cooling 25.0 22.4 85,300 76,400 Model name kW BTU/h Capacity Power source Power input Current COP Type Compressor Motor output Heat Type exchanger Water volume in the coil PQHY-P250YGM-A PQHY-P400YSGM-A Heating Heating Cooling Cooling 31.5 50.0 28.0 45.0 107,500 170,600 95,500 153,500 3N~380/400/415V 50/60Hz 4.69 7.9/7.5/7.2 5.33 4.79 8.0/7.6/7.4 4.68 PQHY-P500YSGM-A Heating Cooling 63.0 56.0 215,000 191,100 5.80 11.01 13.60 11.35 15.06 9.7/9.3/8.9 18.5/17.6/17.0 22.9/21.8/21.0 19.1/18.2/17.5 25.4/24.2/23.3 5.43 4.54 4.63 3.96 3.72 Inverter scroll hermetic compressor 5.0 6.0 9.7 11.6 kW Double coil Double coil Double coil Double coil 9.5 10.5 17.5 19.5 R 3 4.56 5.76 9.12 11.52 m /h Circulating Volume 161 203 322 407 cfh water 16.5 19.5 16.5 19.5 kPa Pressure drop R410A R410A R410A R410A Refrigerant External finish Galvanized sheets Height(H) 1,800(70-7/8") Width(W) mm(in.) 990(39") 1,980(78") External dimension Depth(D) 550(21-11/16") High pressure switch 4.15 MPa (601psi) High pressure protection Protection Over-heat protection Compressor devices Inverter Over-voltage and over-current protection for AC bus, Over-heat protection ø9.52 flare / ø19.05 Flange ø9.52 flare /ø22.2 Flange ø12.7 flare / ø28.58 Flange ø15.88 flare / ø28.58 Flange Refrigerant piping diameter Gas/Liquid 50%~130% of heat sourse unit capacity Indoor Total capacity unit Model P20~250/1~13 Model P20~250/1~22 Model / Quantity Model P20~250/1~24 Model P20~250/1~16 46 50 Noise level dB 53 47 272(600) 208+244(459+538) Net weight kg(lbs.) 208+248(459+547) 275(607) Indoor:15˚CWB~24˚CWB Indoor:15˚CDB~27CDB Indoor:15˚CWB~24˚CWB Indoor:15˚CDB~27˚CDB Indoor:15˚CWB~24˚CWB Indoor:15˚CDB~27˚CDB Indoor:15˚CWB~24˚CWB Indoor:15˚CDB~27˚CDB Operating temperature range Water :10˚C~45˚C Water :10˚C~45˚C Water :10˚C~45˚C Water :10˚C~45˚C Water :10˚C~45˚C Water :10˚C~45˚C Water :10˚C~45˚C Water :10˚C~45˚C kW A 5.95 10.0/9.5/9.1 4.71 Note: 1.Cooling/Heating capacity indicates the maximum value at operation under the following condition. Cooling Indoor:27˚C(80.6˚F)DB/19˚CWB Water temperature: 30˚C(80˚F) Heating Indoor:20˚C(68˚F)DB Water temperature:20˚C(68˚F) 9 Pipe length:7.5m(24- /16Ft) Height difference:0m 2.The ambient temperature of heat source unit has to be kept below 40˚C(104˚F)(dry bulb). The ambient relative humidity of heat source unit has to be kept below 80%. 3.This unit can not be installed in the outdoor.(No protection against the weather.) 4.It is measured in anechoic room. 5.When the total capacity of indoor units exceeds 130% of heat source units capacity, the operating temperature range of circulating water is 15˚C(59˚F)~45˚C(113˚F) External Dimensions ø38 Knockout hole 123 206 318 Piping space (left side pipe) 568 ø27 Knockout hole Water outlet (PT1 1/2 screw) 600 Piping space (upside pipe) 400 400 Front view ø38 Knockout hole ø27 Knockout hole Piping space (left side pipe) Plane view 50 Plane view Service space (front side) 16 95 415 255 140 126 94 2X2-14X20 Oval hole (mounting hole) 602 256 154 ø40 Note 1 Water inlet (PT1 1/2 screw) Note 1 Water outlet (PT1 1/2 screw) ø70 69 415 255 126 495 45 550 990 900(mounting pitch) 45 570(mounting pitch) PQHY-P200,P250YGM-A Fig. A Conn. pipe 200:ø9.52 250:ø9.52 Conn. pipe 200:ø19.05 250:ø22.2 ø62 Knockout hole 1772 (1800) 1590 108 wiring> A 78 B 1397 1497 1579 1598 1626 Refrig. service valve Water inlet (PT1 1/2 screw) ø27 Knockout hole ø38 Knockout hole 939 879 924 Knockout hole ø38 Knockout hole Note 2 Drain(PT1 screw) 127 182 Drain (PT1 screw) 495 Left side view [Accessories] • Refrigerant conn. pipe........... 1pc. • Packing for conn. pipe.................... 1pc. (Attached near the ball valve) • Bushing......................................... 2pcs. 21 B A Model P200 1346 1289 P250 1346 1299 Front view Right side view Rear view Note 1. At the time of product shipment, the front side piping specification serves as the local drainage connection. When connecting on the rear side, please remove the rear side plug sealing corks, and attach to a front side. Ensure there is no leak after the attachment has been fitted. 2. Take notice of service space as Fig. A (In case of single setting, 600mm or more of back space as front space makes easier access when servicing the unit from the rear side.) 3. In case the temperature around the heat source unit has possibility to drop under 0°C, be careful for the following point to prevent the pipe burst by the water pipe freeze-up. • Circulate the water all the time even if the heat source unit is not in operation. • Drain the water from inside of the heat source unit when the heat source unit will not operate for a long term. HEAT SOURCE UNIT Specifications & External Dimensions WY SERIES R410A External Dimensions Piping space (left side pipe) 1990 10 990 990 900(mounting pitch) 900(mounting pitch) Water inlet (PT2 screw) 2X2-14X20 Oval hole (mounting hole) Piping space (upside pipe) 400 550 400 16 ø70 154 69 126 272 418 Water outlet (PT2 screw) 602 2X2-14X20 Oval hole (mounting hole) Plane view Service space (front side) 45 570(mounting pitch) 45 600 PQHY-P400,P500YSGM-A 143 233 318 ø56 568 719 Plane view Front view ø38 Knockout hole Piping space (left side pipe) ø27 Knockout hole Fig. A 418 272 Heat exchanger unit Water outlet (PT2 screw) Compressor unit ø27 Knockout hole 1590 78 Left side view [Accessories] • Refrigerant conn.pipe.............................................. 1pc. (The connecting pipe is fixed with the unit) • Refrigerant conn.pipe........................................... 1pc. (Packaged in the accessory kit) • Refrigerant conn.pipe between HEX unit and Compressor unit ø9.52................................................................................ 2pcs. (Packaged in the accessory kit) ø19.05.............................................................................. 2pcs. (Packaged in the accessory kit) ø25.4................................................................................ 2pcs. (Packaged in the accessory kit : HEX unit) (The connecting pipe is fixed with the unit : Compressor unit) • Packing for conn.pipe....................................................... 4pcs. (Attached near the ball valve) • Bushing............................................................................. 6pcs. • Extension code for water heat source............................... 1set Drain (PT1 screw) Front view Locally piping ø9.52 ø19.05 ø25.4 ø38 Knockout hole 939 182 Drain (PT1 screw) Refrig. service valve 127 126 624 585 Knockout hole 660 950 Knockout hole 879 Refrig. service valve Water inlet (PT2 screw) 108 1772 Conn. pipe P400:ø12.7 P500:ø15.88 (1800) 131 76 1599 Conn. pipe P400:ø28.58 P500:ø28.58 Conn.pipe between HEX unit and Compressor unit (Extension code for water heat source) Control signal wire Right side view Note 1. At the time of product shipment, the front side piping specification serves as the local drainage connection. When connecting on the rear side, please remove the rear side plug sealing corks, and attach to a front side. Ensure there is no leak after the attachment has been fitted. 2. Take notice of service space as Fig. A (In case of single setting, 600mm or more of back space as front space makes easier access when servicing the unit from the rear side.) 3. In case the temperature around the heat source unit has possibility to drop under 0°C, be careful for the following point to prevent the pipe burst by the water pipe freeze-up. • Circulate the water all the time even if the heat source unit is not in operation. • Drain the water from inside of the heat source unit when the heat source unit will not operate for a long term. 4. Use the extension code for water heat source (option) to take space (more than 2m) between HEX unit Compressor unit. 22 HEAT SOURCE UNIT Specifications & External Dimensions WR2 SERIES R410A Specifications Model name kW BTU/h Capacity Power source Power input Current COP Type Compressor Motor output Type Heat exchanger Water volume in the coil PQRY-P250YGM-A PQRY-P400YSGM-A Heating Heating Cooling Cooling 31.5 50.0 28.0 45.0 107,500 170,600 95,500 153,500 3N~380/400/415V 50/60Hz PQRY-P200YGM-A Heating Cooling 25.0 22.4 85,300 76,400 5.8 11.01 13.6 11.35 15.06 9.7/9.3/8.9 18.5/17.6/17.0 22.9/21.8/21.0 19.1/18.2/17.5 25.4/24.2/23.3 5.43 4.54 4.63 3.96 3.72 Inverter scroll hermetic compressor 6.0 9.7 11.6 5.0 Double coil Double coil Double coil Double coil 10.5 17.5 19.5 9.5 5.76 9.12 11.52 4.56 203 322 407 161 19.5 16.5 19.5 16.5 R410A R410A R410A R410A Galvanized sheets 1,800(70-7/8") 990(39") 1,980(78") 550(21-11/16") High pressure switch 4.15 MPa (601psi) Over-heat protection Over-voltage and over-current protection for AC bus, Over-heat protection ø15.88 flare / ø19.05 Flange ø19.05 flare /ø22.2 Flange ø22.2 flare / ø28.58 Flange ø22.2 flare / ø28.58 Flange 50%~150% of heat sourse unit capacity kW A 4.69 7.9/7.5/7.2 5.33 4.79 8.0/7.6/7.4 4.68 kW R m3/h Circulating Volume cfh water kPa Pressure drop Refrigerant External finish Height(H) Width(W) mm(in.) External dimension Depth(D) High pressure protection Protection Compressor devices Inverter Refrigerant piping diameter gas / Liquid Total capacity indoor Model / Quantity unit dB Noise level kg(lbs) Net weight Operating temperature range PQRY-P500YSGM-A Heating Cooling 63.0 56.0 215,000 191,100 5.95 10.0/9.5/9.1 4.71 Model P20~250/1~15 46 263(580) Indoor:15˚CWB~24˚CWB Indoor:15˚CDB~27CDB Water :10˚C~45˚C Water :10˚C~45˚C Model P20~250/1~19 47 266(587) Indoor:15˚CWB~24˚CWB Indoor:15˚CDB~27˚CDB Water :10˚C~45˚C Water :10˚C~45˚C Note: 1.Cooling/Heating capacity indicates the maximum value at operation under the following condition. Cooling Indoor:27˚C(80.6˚F)DB/19˚CWB Water temperature: 30˚C(80˚F) Heating Indoor:20˚C(68˚F)DB Water temperature:20˚C(68˚F) Pipe length:7.5m(24-9/16Ft) Height difference:0m 2.The ambient temperature of heat source unit has to be kept below 40˚C(104˚F)(dry bulb). The ambient relative humidity of heat source unit has to be kept below 80%. Model P20~250/1~24 50 208+232(459+512) Indoor:15˚CWB~24˚CWB Indoor:15˚CDB~27˚CDB Water :10˚C~45˚C Water :10˚C~45˚C Model P20~250/1~24 53 208+236(459+521) Indoor:15˚CWB~24˚CWB Indoor:15˚CDB~27˚CDB Water :10˚C~45˚C Water :10˚C~45˚C 3.This unit can not be installed in the outdoor.(No protection against the weather.) 4.It is measured in anechoic room. 5.When the total capacity of indoor units exceeds 130% of heat source units capacity, the operating temperature range of circulating water is 15˚C(59˚F)~45˚C(113˚F) External Dimensions ø38 Knockout hole 154 123 206 318 Water outlet (PT1 1/2 screw) 600 Front view Piping space (left side pipe) Fig. A Plane view ø27 Knockout hole Piping space (upside pipe) 400 ø38 Knockout hole ø27 Knockout hole 568 50 Plane view Service space (front side) 16 95 415 255 140 126 94 256 69 415 255 126 ø40 Note 1 Water outlet (PT1 1/2 screw) ø70 550 Note 1 Water inlet (PT1 1/2 screw) 495 Piping space (left side pipe) 2X2-14X20 Oval hole (mounting hole) 400 45 602 990 900(mounting pitch) 45 570(mounting pitch) PQRY-P200,P250YGM-A Conn. pipe 200:ø15.88 250:ø19.05 Conn. pipe 200:ø19.05 250:ø22.2 ø62 Knockout hole 1772 (1800) 1590 108 wiring> A 78 B 1579 1598 1626 1397 1497 Refrig. service valve Water inlet (PT1 1/2 screw) ø27 Knockout hole ø38 Knockout hole 939 879 924 Knockout hole ø38 Knockout hole Note 2 Drain(PT1 screw) 127 182 Drain (PT1 screw) 495 Left side view [Accessories] • Refrigerant conn. pipe.......... 1pc. (The connecting pipe is fixed with the unit) • Refrigerant conn. pipe......... 1pc. (Packaged in the accsessory kit) • Packing for conn. pipe.................................... 1pc. (Attached near the ball valve) • Bushing......................................................... 2pcs. 23 B A Model P200 1347 1289 P250 1342 1299 Front view Right side view Rear view Note 1. At the time of product shipment, the front side piping specification serves as the local drainage connection. When connecting on the rear side, please remove the rear side plug sealing corks, and attach to a front side. Ensure there is no leak after the attachment has been fitted. 2. Take notice of service space as Fig. A (In case of single setting, 600mm or more of back space as front space makes easier access when servicing the unit from the rear side.) 3. In case the temperature around the heat source unit has possibility to drop under 0°C, be careful for the following point to prevent the pipe burst by the water pipe freeze-up. • Circulate the water all the time even if the heat source unit is not in operation. • Drain the water from inside of the heat source unit when the heat source unit will not operate for a long term. HEAT SOURCE UNIT Specifications & External Dimensions WR2 SERIES R410A External Dimensions 1990 10 990 Piping space (left side pipe) 990 900(mounting pitch) 900(mounting pitch) Water inlet (PT2 screw) 550 16 154 69 126 272 418 Water outlet (PT2 screw) 400 2X2-14X20 Oval hole (mounting hole) Plane view Service space (front side) Piping space 400 (upside pipe) 602 2X2-14X20 Oval hole (mounting hole) 45 570(mounting pitch) 45 600 PQRY-P400,P500YSGM-A ø70 143 233 318 ø56 568 719 Plane view Front view ø38 Knockout hole Piping space (left side pipe) ø27 Knockout hole Fig. A 418 272 Heat exchanger unit ø27 Knockout hole Compressor unit 108 1772 Refrig. service valve (1800) 1599 131 76 1590 Conn. pipe ø28.58 Conn. pipe ø22.2 Water outlet (PT2 screw) 78 Water inlet (PT2 screw) Left side view [Accessories] • Refrigerant conn.pipe....................................................... 2pcs. (The connecting pipe is fixed with the unit) • Refrigerant conn.pipe between HEX unit and Compressor unit ø9.52................................................................................ 2pcs. (Packaged in the accessory kit) ø19.05.............................................................................. 2pcs. (Packaged in the accessory kit) ø25.4................................................................................ 2pcs. (Packaged in the accessory kit : HEX unit) (The connecting pipe is fixed with the unit : Compressor unit) • Packing for conn.pipe....................................................... 4pcs. (Attached near the ball valve) • Bushing............................................................................ 2pcs. • Extension code for water heat source............................... 1set Drain (PT1 screw) 939 Right side view Front view Locally piping ø9.52 ø19.05 ø25.4 ø38 Knockout hole 182 Drain (PT1 screw) 879 Refrig. service valve 127 585 Knockout hole 648 126 660 950 Knockout hole Conn.pipe between HEX unit and Compressor unit (Extension code for water heat source) Control signal wire Note 1. At the time of product shipment, the front side piping specification serves as the local drainage connection. When connecting on the rear side, please remove the rear side plug sealing corks, and attach to a front side. Ensure there is no leak after the attachment has been fitted. 2. Take notice of service space as Fig. A (In case of single setting, 600mm or more of back space as front space makes easier access when servicing the unit from the rear side.) 3. In case the temperature around the heat source unit has possibility to drop under 0°C, be careful for the following point to prevent the pipe burst by the water pipe freeze-up. • Circulate the water all the time even if the heat source unit is not in operation. • Drain the water from inside of the heat source unit when the heat source unit will not operate for a long term. 4. Use the extension code for water heat source (option) to take space (more than 2m) between HEX unit and Compressor unit. 24 BC CONTROLLER Specifications & External Dimensions CMB-P-V-GB BC Controller for R2/WR2 SERIES CMB-P-V-G CMB-P-V-GA R410A CMB-P-V-GB Specifications Model name Number of branch Power source CMB-P104V-G CMB-P105V-G CMB-P106V-G CMB-P108V-G CMB-P1010V-G 5 4 6 8 10 ~220/230/240V 50Hz/60Hz 0.067/0.076/0.085 0.082/0.093/0.104 0.097/0.110/0.123 0.127/0.144/0.161 0.156/0.177/0.198 0.030/0.034/0.038 0.038/0.043/0.048 0.045/0.051/0.057 0.060/0.068/0.076 0.075/0.085/0.095 0.054/0.061/0.067 0.066/0.074/0.082 0.078/0.088/0.097 0.102/0.115/0.127 0.126/0.141/0.156 0.024/0.027/0.030 0.030/0.034/0.038 0.036/0.041/0.045 0.048/0.054/0.060 0.060/0.068/0.075 0.31/0.34/0.36 0.38/0.41/0.44 0.45/0.48/0.52 0.58/0.63/0.68 0.71/0.77/0.83 0.14/0.15/0.16 0.18/0.19/0.20 0.21/0.23/0.24 0.28/0.30/0.32 0.35/0.37/0.40 0.25/0.27/0.28 0.30/0.33/0.35 0.36/0.39/0.41 0.47/0.50/0.53 0.58/0.62/0.65 0.11/0.12/0.13 0.14/0.15/0.16 0.17/0.18/0.19 0.22/0.24/0.25 0.28/0.30/0.32 Galvanizing Cooling heating Cooling 60Hz heating Cooling 50Hz heating Cooling 60Hz heating 50Hz Power input kW Current A External finish Indoor unit capacity connectable to 1 branch * Conncctable Outdoor unit Height Width Depth CMB-P1013V-G CMB-P1016V-G CMB-P108V-GA CMB-P1010V-GA CMB-P1013V-GA CMB-P1016V-GA CMB-P104V-GB 13 16 8 10 13 16 4 ~220/230/240V 50Hz/60Hz 0.201/0.288/0.255 0.246/0.279/0.312 0.127/0.144/0.161 0.156/0.177/0.198 0.201/0.228/0.255 0.246/0.279/0.312 0.060/0.068/0.076 0.097/0.110/0.123 0.119/0.135/0.151 0.060/0.068/0.076 0.075/0.085/0.095 0.097/0.110/0.123 0.119/0.135/0.151 0.030/0.034/0.038 0.162/0.182/0.201 0.198/0.222/0.246 0.102/0.115/0.127 0.126/0.141/0.156 0.162/0.182/0.201 0.198/0.222/0.246 0.048/0.054/0.060 0.078/0.088/0.097 0.096/0.108/0.119 0.048/0.054/0.060 0.060/0.068/0.075 0.078/0.088/0.097 0.096/0.108/0.119 0.024/0.027/0.030 0.92/1.00/1.07 1.12/1.22/1.30 0.58/0.63/0.68 0.71/0.77/0.83 0.92/1.00/1.07 1.12/1.22/1.30 0.28/0.30/0.32 0.45/0.48/0.52 0.55/0.59/0.63 0.28/0.30/0.32 0.35/0.37/0.40 0.45/0.48/0.52 0.55/0.59/0.63 0.14/0.15/0.16 0.74/0.80/0.84 0.90/0.97/1.03 0.47/0.50/0.53 0.58/0.62/0.65 0.74/0.80/0.84 0.90/0.97/1.03 0.22/0.24/0.25 0.36/0.39/0.41 0.44/0.47/0.50 0.22/0.24/0.25 0.28/0.30/0.32 0.36/0.39/0.41 0.44/0.47/0.50 0.11/0.12/0.13 Galvanizing CMB-P108V-GB 8 0.119/0.135/0.151 0.060/0.068/0.076 0.096/0.108/0.119 0.048/0.054/0.060 0.55/0.59/0.63 0.28/0.30/0.32 0.44/0.47/0.50 0.22/0.24/0.25 Model P140 or smaller Model P140 or smaller PURY-P200~650YGM-A *2 CMB-P108V~P1016V-GA 289 mm 284 1098 1110 mm 648 520 mm 432 For P200 type: ø15.88 Brazed For P250, P300, P350 type: ø19.05 Brazed High pressure For P200 type: ø15.88 Brazed For P400 to P500 type: ø22.22 Brazed pipe For P250, P300, P350 type: ø19.05 Brazed To outdoor For P550 to P650 type: ø28.58 Brazed unit For P200 type: ø19.05 Brazed For P200 type: ø19.05 Brazed Low pressure For P250, P300 type: ø22.2 Brazed For P250, P300 type: ø22.2 Brazed pipe For P350 to P650 type: ø28.58 Brazed For P350 type: ø28.58 Brazed ø9.52 Flare ø9.52 Flare Liquid pipe Refrigerant (ø6.35 with attached reducer used, ø12.7 with optional joint pipe used) To indoor (ø6.35 with attached reducer used, ø12.7 with optional joint pipe used) piping ø15.88 Flare unit ø15.88 Flare Gas pipe diameter (ø12.7 with attached reducer used, ø19.05 with optional joint pipe used) (ø12.7 with attached reducer used, ø19.05 with optional joint pipe used) For total capacity below P200 type: ø19.05 Brazed Low press gas For total capacity below P201 to P300 type: ø22.2 Brazed pipe For total capacity below P301 to P350 type: ø28.58 Brazed To another High press gas For total capacity below P200 type: ø15.88 Brazed BC controller pipe For total capacity below P201 to P350 type: ø19.05 Brazed For total capacity below P300 type: ø9.52 Brazed Liquid pipe For total capacity below P301 to P350 type: ø12.7 Brazed VP-25 Drain pipe VP-25 Net weight 24 27 29 34 39 47 54 44 49 57 64 22 32 •Drain connection pipe (with flexible hose and insulation) •Drain connection pipe (with flexible hose and insulation) Accessories •Reducer •Reducer *1 Use optional joint pipe combining 2-branch when the total unit capacity exceeds P140. *2 Additional pipework is needed to connect with P300 type or lower outdoor unit. Use the reducer (standard accessory) when the indoor unit Model P50 or smaller is connected. PURY-P200, 250, 300, 350YGM-A 284 648 432 External Dimensions 4 5 6 7 8 9 10 11 12 13 14 15 16 23 Service space (200) 648 702 (Lifting bolt pitch) 70 76 128 1 2 3 4 5 6 7 8 255 284 Connection pipe of indoor unit (Liquid) ø9.52 (Flare) 60XA=B 60 ø15.88 (Flare) Connection pipe of indoor unit (Gas) ø15.88 (Flare) 200 ø31 Connnection pipe of outdoor unit (High pressure) For P200 type: ø15.88 Brazed For P250, P300 type: ø19.05 Brazed For P350 type: ø22.22 Brazed For P400 to P650 type: ø28.58 Brazed 14 Detail of X section 210 388 (Lifting bolt pitch) Connection pipe of SUB BC CONTROLLER (Liquid) Total capacity of indoor unit For 300 or less: ø9.52 For 301 or over: ø12.7 (with accessory) Connection pipe of SUB BC CONTROLLER (Low pressure) Total capacity of indoor unit For 200 or less: ø19.05 (with accessory) From 201 to 300: ø22.2 For 301 or over: ø28.58 (with accessory) 66 74 1110 23 1164 (Lifting bolt pitch) 90 76 Access door 450 74 Service space 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 260 128 27 60 1 70 Connection pipe of indoor unit (Gas) 200 • Refrigerant conn. pipe...............1pc • Refrigerant conn. pipe..............1pc • Reducer (Large, Small).....Quantity for all connection • Drain hose (VP-25 connection)............................1pc • Hose band............................................................1pc • Tie band...............................................................1pc Note 1. Suspesion bolt (ø10), washer (M10) and nut (M10) prepare in the field. 2. Take notice of service space as follows: (Please give attention not to occupy service space by letting ducts and pipes through) In the following, Access door in service space is a door for service. There fore, another door is necessary to unload products. 3. Please take space to connect SUB BC CONTROLLER. 200 200 Connection pipe of indoor unit (Liquid) ø9.52 (Flare) 70 60XA=B 700 Connection pipe of outdoor unit (Low pressure) For P200 type: ø19.05 Brazed For P250, P300 type: ø22.2 Brazed For P350 type: ø28.58 Brazed For P400 to P650 type: ø28.58 Brazed 289 128 250 64 64 103 268 333 130 Connection pipe of SUB BC CONTROLLER (High pressure) Total capacity of indoor unit For 200 or less: ø15.88 (with accessory) For 201 or over: ø19.05 103 Control box X 450 Y Detail of Y section 268 Drain piping VP-25 connection 70 CMB-P108,1010,1013,1016V-GA 30 12 Drain hose (Accessory) ø15.88 (Flare) 200 CMB-P108V-GA CMB-P1010V-GA CMB-P1013V-GA CMB-P1016V-GA A 7 9 12 15 B 420 540 720 900 (700) 250 Access door 450 70 X Band (accessory) 25 B 180 420 200 298 (Lifting bolt pitch) 64 103 130 Connection pipe of indoor unit (Gas) 200 A 3 7 Control box 27 3 64 Total capacity of indoor unit. For 200 or less: ø19.05 (with accessory) From 201 to 300: ø22.2 For 301 or over: ø28.58 (with accessory) 58 27 60 2 45 181 Connection pipe of indoor unit (Liquid) ø9.52 (Flare) 60XC=D 255 128 Connnection pipe of MASTER BC CONTROLLER (Low pressure) (200) B (Lifting bolt pitch) 1 Y 250 Service space A 23 Connection pipe of outdoor unit (Low pressure) 200: ø219.05 (with accessory) 250, 300: ø22.2 70 76 350: ø28.58 (with accessory) 284 Access door 450 CMB-P104V-GB CMB-P108V-GB Connnection pipe of MASTER BC CONTROLLER (Liquid) Total capacity of indoor unit. For 300 or less: ø9.52 For 301 or over: ø12.7 (with accessory) Connnection pipe of MASTER BC CONTROLLER (High pressure) Total capacity of indoor unit. For 200 or less: ø15.88 (with accessory) For 201 or over: ø19.05 Drain piping VP-25 connection 200 298 (Lifting bolt pitch) 362 248 64 103 64 181 14 Detail of Y section Detail of X section 248 Control box X 130 1098 1152 Drain hose (Accessory) 58 Detail of Y section 702 Band (accessory) D 180 240 300 420 540 720 900 169 Detail of X section Y 648 C 3 4 5 7 9 12 15 (700) 14 70 Connnection pipe of outdoor unit (High pressure) 200: ø15.88 (with accessory) 250, 300, 350: ø19.05 ø31 30 12 Drain piping VP-25 connection B 30 12 CMB-P104V-G CMB-P105V-G CMB-P106V-G CMB-P108V-G CMB-P1010V-G CMB-P1013V-G CMB-P1016V-G Note 1. Suspesion bolt (ø10), washer (M10) and nut (M10) prepare in the field. 2. Take notice of service space as follows; (Please give attention not to occupy service space by letting ducts and pipes through) In the following, Access door in service space is a door for service. There fore, another door is necessary to unload products. 3. Can't use singleness. (MASTER BC CONTROLLER is necessary.) • Reducer.....Quantity for all connections • Drain hose (VP-25 connection).......1pc • Pipe cover for drain hose.................1pc • Hose band.......................................1pc • Tie band...........................................2pc ø31 A Band (accessory) Drain hose (Accessory) Unit : mm CMB-P104,108V-GB Note 1. Suspesion bolt (ø10), washer (M10) and nut (M10) prepare in the field. 2. Take notice of service space as follows; (Please give attention not to occupy service space by letting ducts and pipes through) • Pipe cover for drain hose...................................................1pc In the following, Access door in service space • Hose band..........................................................................1pc is a door for service. There fore, another door • Tie band.............................................................................1pc is necessary to unload products. 362 CMB-P104,105,106,108, • Refrigerant conn. pipe (Large, Small).....2pc • Refrigerant conn. pipe............................1pc • Reducer (Large, Small)..................Quantity for all connection 1010,1013V-G • Drain hose (VP-25 connection)..........................................1pc Wide selection of indoor units Ceiling cassette (4way air flow) Ceiling suspended PLFY-P VCM-E PLFY-P VAM-E PCFY-P VGM-E Model P20 P25 P32 P40 P50 P63 P80 P100 P125 Capacity 2.2kW 2.8kW 3.6kW 4.5kW 5.6kW 7.1kW 9.0kW 11.2kW 14.0kW Ceiling cassette (2way air flow) Model P40 P63 P100 P125 Capacity 4.5kW 7.1kW 11.2kW 14.0kW Wall mounted PLFY-P VLMD-E Model P20 P25 P32 PKFY-P VAM-E PKFY-P VGM-E PKFY-P VFM-E P40 P50 P63 P71 P80 P100 P125 Capacity 2.2kW 2.8kW 3.6kW 4.5kW 5.6kW 7.1kW 8.0kW 9.0kW 11.2kW 14.0kW Ceiling cassette (1way air flow) Model P20 P25 P32 P40 P50 P63 P100 Capacity 2.2kW 2.8kW 3.6kW 4.5kW 5.6kW 7.1kW 11.2kW Floor standing New PFFY-P VLEM-E PFFY-P VLRM-E PMFY-P VBM-E Model P20 P25 P32 P40 Capacity 2.2kW 2.8kW 3.6kW 4.5kW Ceiling concealed Model P20 Capacity 2.2kW P25 P32 P40 P50 P63 2.8kW 3.6kW 4.5kW 5.6kW 7.1kW Fresh Air Intake PEFY-P VMH-E-F New PEFY-P VMR-E-L/R PEFY-P VMM-E PEFY-P VML-E PFFY-P VKM-E PEFY-P VMH-E New PEFY-P VMS-E Model P20 P25 P32 P40 P50 P63 P71 P80 P100 P125 P140 P200 P250 Model P80 P140 P200 P250 Capacity 2.2kW 2.8kW 3.6kW 4.5kW 5.6kW 7.1kW 8.0kW 9.0kW 11.2kW 14.0kW 16.0kW 22.4kW 28.0kW Capacity 9.0kW 16.0kW 22.4kW 28.0kW 26 INDOOR UNIT Ceiling cassette type PLFY-P VCM-E/VAM-E 4-way airflow PLFY-P VCM-E PLFY-P VAM-E VCM VAM The new compact cassette VCM is suitable for 2x2 ceiling! compact body to match with 2feets (600mm) x 2feets (600mm) ceiling design (VCM) 570mm Easy Installation Only two panel sizes–perfectly suited to various installation configurations Only two panel sizes are available,650mm(255/8in.) for the compact VCM and 950mm(377/16in.) for the power cassette VAM. The VCM is lightweight min.15kg(34lbs)(P20/P25) PLFY-VCM Type Superb Features Drain water pipe lifted to 850mm(33-1/2in.) (power cassette VAM) First in the industry to offer 72 airflow patterns (power cassette VAM) The drain piping of the VAM can be positioned anywhere up to 850mm(33-1/2in.) from the ceiling's surface, allowing greater freedom with long cross-piping and more versatility with piping layouts (VCM: 500mm(19-11/16in.)). The 72 different airflow patterns provide the best solution for varying room layouts and air-conditioning requirements. For extra versatility, you can also select from two-, three- or four-way outlets. What's more, the addition of separate motors to the individual vanes enables manual control that-together with remote control vane settings-make possible highly customized and flexible airflow patterns. PLFY-VAM Type 850mm (33-1/2in.) 650mm (25-5/8in.) (compact cassette VCM) The new compact cassette VCM has a unit height of only 208mm*1, to realize neat installation in low-ceiling situations with very limited space. *:8-1/4in Only 208mm*! 27 4-, 3-, or 2way outlet selection 950mm (37-7/16in.) Unit height of only 208mm*1 great for low-ceiling space situations 570mm Handy corner-pocket design simplifies maintenance and installation (power cassette VAM) By using the handy corner pockets equipped on four corners of the grille, maintenance work such as drain pan cleaning and height adjustment can be accomplished without removing the grille. It is also easier to adjust the ceiling height of the indoor unit during installation. Fixed airflow direction per vane Motor for the vane 72 airflow patterns *Optional air outlet shutter plate is necessary for two-or three-way airflow settings. The noise level may increase during two-or three-way airflow setup. *For VCM model, 2 or 3 way airflow is not available. INDOOR UNIT Ceiling cassette type   )  PLFY-P VCM-E PLFY-P VAM-E - + %  % &  '      # These units are ideal for maintaining constant temperatures in environments that have equipment such as refrigerate showcases. Individual vane angle adjustment enables precise airflow control to specific areas of the store to reduce unnecessary air conditioning of areas such as refrigerated showcases. Remote control setting for two directions '  - )   )  )  - *   ) .    ) -     # Mitsubishi Electric has developed a new airflow control mechanism where a projection inside the air passage distributes air evenly over the vane's upper and lower surface while two additional projections at the air outlet's exit adjust the angle of the airflow. This helps to prevent indoor air from rising, stopping it from hitting the surface of the ceiling to reduce the likelihood of soiling from smudging and condensation. ( )      *   )  + , # The airflow of the VAM power cassette is powerful enough to warm atrium-type ceilings up to 4.2 meter(13-13/16Ft) in height. 4-way high ceiling 2 (VAM) 4-way standard (VAM) 3.2m (10-1/2Ft) 4.2m (13-13/16Ft) Fixed vane for two directions Fixed 3.6m (11-13/16Ft) Smudging and the new airflow control mechanism Fixed Outside Inside 3-way standard (VAM) Specifications according to ceiling height and number of vents      1 Standard Top or bottom airflow setting via remote controller Fixed 3 2 Grille Vane Fixed Refrigerated showcase not affected by air conditioning 1 2 3 A projection is created on the outside, where the airflow is fastest. This diverts the airflow and distributes it evenly over the upper and lower surfaces of the Vane. The air outlet exit also has projections to prevent air from rising within the room and stopping it from hitting the ceiling. Wider airflow setting reduces annoying drafts  30° horizontal position -+ . + .   /  -    # For easy connection to branch ducts, knockout holes are designed to fit both round and square ducts. Matching the shape of the duct fringe provides more flexibility during installation.      30° 70° 70° vertical position When cooled air is expelled horizontally, it tends to cling to the surface of the ceiling. This cools the surface down and causes condensation, which attracts dust from the room's interior to soil the ceiling's surface. High ceiling 1 High ceiling 2   3.2 3.6 4.2 3.6 4.0 4.2  4.0 4.2 --- *VCM:2.7m(standard/4way only) %   --  * . -    # When the air conditioner is not operating, the vane shutter closes automatically to conceal the air outlet and create an aesthetically appealing flat surface.* *This feature will not activate when the vane is set at fixed position. 0   ) *  +    - -     # The unique suction mechanism prevents indoor air from rising to eliminate condensation on the vane and make bristles unnecessary. During operation When turned off 1  2 ) ) . 3   -     4 -    #  !"#          Indoor air quality is significantly enhanced by the direct intake of fresh exterior air. An optional multi-function casement is also available (only for VAM) for the intake of a larger volume of air.  !"#$ !"#   28 INDOOR UNIT Ceiling cassette type 2-way airflow (drain-up mechanism is built in) PLFY-P VLMD-E PLFY-P VLMD-E Slim body of 290 mm* height. (*11- / 7 16in.) Slim body - only 290mm height The slimline body is highly suitable for installation in narrow ceiling spaces and for replacing obsolete air-conditioning equipment in older buildings. The main unit is only 290mm* height. 290mm * (*: 11-7/16in.) Equipped with drain water lift-up mechanism as standard Terminal block on outside of main unit makes wiring easier The drain can be positioned anywhere up to 600mm* from the ceiling's surface, providing greater freedom with long cross-piping and allowing more versatility with piping layouts.(*: 23-5/8in.) Drain height max. 593mm(23-3/8in.) Main unit height - 290mm(11-7/16in.) Ceiling surface Newly designed decorative panel with air flow switching and swing functions as a standard feature 593 (unit: mm) Compact unit and low noise level attained! Fresh air directly taken in Fresh air can be taken in to the main unit directly (optional accessories needed. 29 INDOOR UNIT Ceiling cassette type !   PMFY-P VBM-E PMFY-P VBM-E                              Unit body size has been standardized for all models at 854mm for easier installation. Body weight is also only 14kg for the main unit and 3kg for the panel, making this unit one of the lightest in the industry.        The drain can be positioned anywhere up to 600mm* from the ceiling's surface.(*: 23-5/8in.) max. 402 (15-7/8) max. 600*     Newly developed airflow control technology reduces noise level to only 27dB (P20VBM) for industry-leading quiet operation. 230 (9-11/16)  198 (7-13/16) unit: mm(in.) 30 INDOOR UNIT Ceiling concealed type New PEFY-P VMR-E-L/R PEFY-P VMR-E-L/R Problem solver for residential hotels, museums, libraries, or hospitals where low noise is especially a must! Inlet Card Key Switch Noise measurement point Noise measurement point *According to the data measured in Mitsubishi Electric laboratory Operable by card key switch Prepared a contact for a card key. It’s possible to operate / stop by taking a card key in and out. Enables to install for symmetric design room Both of Left piping / Right piping, control box, are available. It's selectable for layout of each room. Plus easy maintenance from the access door in the prefabricated bath. *Seen from an anterior view, the pipe and control box are on the right side of –R type. 31 Ultra low noise Realizing the low level noise that is NC21 around a bed and N22 around a desk when the high notch. It contributes to create a quiet indoor environment. *Outlet is elbow-constructed using a glass wool duct. The noise level is changed by the room size or the setting condition of the unit. Energy-saving by prevention of forgetting the switch off Compact & Simple operation remote controller is available. *This remote controller can operate only start / stop, Indoor temperature control and wind speed control. Centralized remote controller must be used together. Enables a prevention to forget the switch in a vacant room off by the centralized remote controller like G-50. INDOOR UNIT Ceiling concealed type PEFY-P VMS-E New PEFY-P VMS-E Increased design flexibility for the places where low noise operation is especially needed from an ultra thin body. Changeable static pressure (4 stage 5-15-35-50Pa) Ultra low height unit with 200mm high Can be installed easily in tight spaces, such as ceiling cavities or drop-ceilings. Filter is attached as standard. More than 20mm Drain lift-up pump is attached as standard. More than 20mm Changeable air flow rate (3 stage low-middle-high) Ceiling surface Access door Make the access door at the appointed position properly unit: mm for service maintenance. Reduced noise thanks to the use of newly designed centrifugal fan and coil Noise level table (Standard static pressure) Capacity Noise Level Fan Speed dB(A) P20 P25 P32 High 27 27 30 Mid 25 25 28 Low 22 22 25 32 INDOOR UNIT Ceiling concealed type PEFY-P VML-E PEFY-P VML-E Increased design flexibility for hotel and residential use. Low static pressure (5Pa) meets an application requiring direct air flow Low height unit with 225mm* high *: 8-7/8in. Can be installed easily in tight spaces, such as ceiling cavities or drop-ceilings. Notes: Drain lift-up pump not applicable. Changeable air flow rate (3 stage low-middle-high) Service space:500(19-11/16) or more Hole pitch 100(3-15/16) or more 20(13/16) or more 245(9-11/16)+Drain covering configuration 225 height (8-7/8) Flexible installation by rear or bottom return air inlet. 30(1-3/16) Access door 20/25/32 Model Filter is attached as standard. Reduced noise thanks to the use of newly designed centrifugal fan Noise level table (Standard static pressure 220V) Capacity Noise Level Fan Speed dB(A) P20 P25 P32 High 36 36 40 Mid 29 29 29 Low 25 25 25 Note: In the case of bottom inlet, the operating noise is louder than in the case of rear inlet. 33 unit: mm(in.) Drainage lines may be connected on either the right or left side. Perfect for use in hotels and other places where line placement is a problem. INDOOR UNIT Ceiling concealed type PEFY-P VMM-E PEFY-P VMM-E Achieving creative air conditioning design through a rich array of system materials. Flexible installation for a variety of layouts Long room L-shaped rooms Air outlet side compatible with a variety of ducts (optional) Multiple installation patterns for assorted applications and locations Bottom intake (directly attached to panel) Adjustable setting of external static pressure to meet system configuration and installation conditions Static pressure settings can be increased to adjust to all kinds of ducts as well as functional upgrade option (high performance filter etc). An increase from the standard 50Pa to 130* Pa is possible to cope with various layout configurations. Slim 295mm main unit with optional drain up mechanism ensures up to 600 mm of lift Max. 600 Max. 416 184 Bottom intake (using canvas duct) Maintenance panel with air intake All-duct system Ceiling chamber system (1) A rear intake can also be used Square duct flange Maintenance panel Ceiling chamber system (2) *For P100~P125. Room with fixed ceiling fixtures A bottom intake can also be used Maintenance panel Hanging ceiling installation Square duct flange System ceiling 295 34 INDOOR UNIT Ceiling concealed type PEFY-P VMH-E PEFY-P VMH-E Increased design flexibility from sufficient external static pressure allow authentic duct air- conditioning with an elegant interior layout. One-side maintenance Maximum external static pressure 200Pa The additional external static pressure capacity provides flexibility for duct extension, branching and air outlet configuration. P40 P50 P63 P71 P80 P100 P125 P140 P200 P250 External static pressure (Pa) 220V 50/100/200 230/240V 100/150/200 380V 110/220 400/415V 130/260 All maintenance to the unit, including fan inspection and fan motor removal, can be conducted from the inspection opening on one side. Drain up mechanism (option) ensures up to 550mm* of lift *: 21-11/16in. The introduction of an upper drain mechanism allows the drain connection to be raised as high as 550mm*, allowing more freedom in piping layout design and reducing horizontal piping requirements. Reduced noise thanks to the use of newly designed centrifugal fan Noise level table (Standard static pressure 220V) Capacity Noise High Level Fan Speed Low dB(A) P40 P50 P63 P71 P80 P100 P125 P140 34 34 38 39 41 42 42 42 27 27 32 32 35 34 34 34 222mm (8-3/4in.) MAX. 550mm (21-11/16in.) 328mm (12-15/16in.) 35 INDOOR UNIT Ceiling suspended type PCFY-P VGM-E PCFY-P VGM-E                             Seek and slim with stylishly curved lines, the PCFY series blends right into any interior. It also features a single air outlet which allows the auto vane to act as a shutter when the unit is turned off.               The most suitable airflow can be selected for ceilings up to 3.5m high, enhancing air-conditioning efficiency and comfort.  Ceiling height 2.7m(8-7/8Ft)    3.5m(11-1/2Ft) !                The auto vane swings up and down automatically to distribute air more evenly to every corner of the room. Auto vane Swing The new direct suspension system eliminates the task of removing the attachment fixture from the main unit, greatly shortening installation time.            1. Leave attachment fixture attached to main unit. 2. Suspend the attachment fixture from the suspension bolts. 3. Simply tighten the nuts to secure the unit. Ceiling surface Suspension bolts Attachment fixture Air outlet *A one-touch suspension is also available: simply suspend the main unit from the attachment fitting after securing the latter to the ceiling.                        36 INDOOR UNIT Wall mounted type PKFY-P VAM PKFY-P VAM-E PKFY-P VGM-E PKFY-P VFM-E PKFY-P VGM PKFY-P VAM-E PKFY-P VGM-E PKFY-P VFM-E PKFY-P VFM Elegant Design and Compact Dimensions Ideal for Offices, Stores and Residential Uses. Capacity range Capacity P20 P25 P32 P40 P50 P63 P100 Quiet operation (PKFY-P VGM) VAM Among the quietest in the industry VGM Airflow passage configuration that assures quiet operations VFM Compact design with 990mm* width (PKFY-P VGM) Width reduced by 20% to a compact 990mm*. *: 39in. Extra compactness has been achieved thanks to a 20%(260mm(10-1/4in.)) reduction in which compared with previous models. Compact 295mm(11-5/8in.) high body fits snugly in even limited spaces (PKFY-P VAM) Lightweight 8.5kg(20lbs) unit easy to transport and install (PKFY-P VAM) Auto-flap shutter enhances good looks 37 1 1. The unit incorporates a randon pitch cycling fan. By changing fan intervals reduction in airflow. Optimal design of the airflow passage gives a shorted fan diameter and allows a highly compact installation. 2. Thanks to a highly practical casing configuration, airflow generated by the fan is distributed uniformly. 3. Due to careful positioning of the vertical vane axis, air is blown evenly from the fan. This prevents mixing with secondary air, and also suppresses condensation. 2 3 Front grille opens out - easy filter cleaning (PKFY-P VGM) In room air conditioning style, the grille opens out allowing the filter to be removed. The filter and open grille can therefore be thoroughly and easily cleaned. Front power supply box for easier wiring even after installation The front power supply box allows electrical wiring work to be done after the indoor unit has been installed. For easier installation, all the screws required for securing the indoor unit to the wall are accessible from the front of the unit. Front grille opens out 5-way piping provides more flexibility in selecting installation sites All piping including drainage can be connected from the rear, right, base, and left of the unit, providing much greater flexibility out piping and selecting installation site. INDOOR UNIT Floor standing type New PFFY-P VKM-E PFFY-P VKM-E For living rooms, bed rooms, or offices where a sophisticated design is required. The latest Mitsubishi innovation – floor-standing air-conditioner sophisticated in design, rich in function. Quiet Operation Mitsubishi Electric air conditioners have always been some of the quietest model available in the market. Our new floorstanding models are no exception. It can create a silent and comfortable space where the occupants would not even recognize the existence ONLY of air conditioner operation. ✻2.5kw class 27dB Noise level Quiet passenger Human Subway car interior car interior (40km/h) Library interior 80dB 60dB 40dB hearing limits Sound of rustling leaves (Extremely quiet)  10dB     Sophisticated Design Optimum Air Distribution From Mitsubishi Electric, an Deluxe look in “Glossy Pure White” color innovative new floorstanding airconditioner. Our Sleek louvers look just like pleasing mix of flat panels streamlined form and diversified function. Smart upper/lower air outlets Engineered to keep close when switched off room walls free, furnish comfy cooling in summer, toasty heating in winter. The “Glossy Pure White” colour ensures a deluxe look, the perfect match for any room. Both upper and lower air outlets remain closed when switched OFF, in a smart and striking image. A superb new air-conditioner from Mitsubishi, providing a handsome fit for your own distinctive interior. Comfy room temperatures are realized by the optimum, powerful and efficient air distribution through upper and lower air outlets. The upper vane angle is remote controllable, with 5 air flow direction levels (+Swing and Auto modes) and 4 wind power levels (+Auto mode). By setting the vane angle almost vertical, annoying direct wind can be avoided for your better comfort. Slim but Mighty 600 mm The unit body is slim and trim, the essence in compact. An ideal size for living rooms, bedrooms, attics and more. The removable and 200 washable front panel makes 700 mm mm cleaning a snap. Easy and regular cleaning allows your air-conditioner stay beautiful while keeping its energy-efficient operation always possible. The air from both upper and lower air outlets is optimally controlled and distributed evenly to every corner of the room. In heating mode, the warm air is smartly controlled to stay at the floor level: Your feet do not feel chilled any more! 14 16 18 20 22 24 26 ˚C 38 INDOOR UNIT Floor standing type PFFY-P VLEM-E PFFY-P VLEM-E                                                                          The compact body of 220mm(7-7/8in.) in depth can be easily installed in the perimeter zone for effective air conditioning in the perimeter zone.         Optimum dehumidification depending on indoor temperature to prevent over-cooling. Refreshing dehumidification can be attained. INDOOR UNIT Floor mounted concealed type PFFY-P VLRM-E PFFY-P VLRM-E                           The body is concealed in the pericover to pursue harmony with the interior. The compact body of 220mm(7-7/8in.) in depth can be easily installed in the perimeter zone.            Optimum dehumidification depending on indoor temperature to prevent over-cooling. Refreshing dehumidification can be attained. 39 INDOOR UNIT Fresh Air Intake Type PEFY-P VMH-E-F PEFY-P VMH-E-F Fresh Air can be taken in with temperature control. Ideal for Offices, Stores and Restaurant. * Limits of capacity connectable to outdoor unit The Fresh Air intake indoor unit can be installed in any place. Max. 110% of outdoor unit capacity, excepting heating at outdoor temperature of less than -5˚C(23˚F) (100%). The Fresh Air intake indoor unit can take Example fresh outdoor air into any building in any 1. Nurcery home place at any time. Fresh Air intake indoor unit Office, Lobby, Workshop, Rest room, nursery home, Smoking corner, Kitchen in restaurant Fresh Air intake indoor unit 2. Workshop Passage Exhaust air Fresh air Air flow Private room Polluted air Office Private room Workshop Ventilating fan Ventilating fan Installing fresh Air intake indoor unit (Image) Fresh Air intake indoor unit Exhaust air EA Supply air Fresh air OA < Note> Fan remains of in operation during Thermo-OFF. Using this model with other type of indoor unit is recommended for Cold Draft prevention because Cold Draft might occur by using only this model that takes in fresh air. 40 INDOOR UNIT Specifications & External Dimensions For 50Hz Area only PLFY-P VCM-E Specifications PLFY-P20VCM-E Power source ❇1 ❇1 ❇1 Heating capacity ❇1 Cooling Power consumption Heating Cooling Current Heating External finish(Munsel No.) Height Dimension ❇ 2 Width Depth Net weight ❇ 2 Heat exchanger Type Cooling capacity Airflow rate ❇ 2 (Low-Mid-High) Fan External static pressure Type Motor Output Air filter Refrigerant Gas(Flare) pipe diameter Liquid(Flare) Drain pipe diameter Noise level (Lo-Mid-Hi) ❇2 ❇3 PLFY-P25VCM-E PLFY-P32VCM-E PLFY-P40VCM-E ~ (Single phase), 220-230-240V 50Hz 2.2 2.8 3.6 4.5 7,500 9,600 12,300 15,400 5.0 2.5 3,2 4.0 8,500 10,900 13,600 17,100 0.06 0.05 0.06 0.05 0.06 0.06 0.05 0.05 0.28 0.28 0.23 0.23 0.28 0.28 0.23 0.23 Unit: Galvanized sheets with gray heat insulation, Panel: Munsell 0.70Y 8.59/0.97 Unit: 208(8-1/4"), Panel: 20(13/16") Unit: 570(22-1/2"), Panel: 650(25-5/8") Unit: 570(22-1/2"), Panel: 650(25-5/8") Unit: 15.5<3>(35<7>) Unit: 15.5<3>(35<7>) Unit: 17<3>(38<7>) Unit: 17<3>(38<7>) Cross fin (Aluminum plate fin and copper tube) Turbo fan × 1 kW Btu/h kW Btu/h kW kW A A mm(in.) mm(in.) mm(in.) kg(lbs.) m3/min 8-9-10 8-9-10 8-9-11 8-9-11 L/s cfm 133-150-167 283-318-353 133-150-167 283-318-353 133-150-183 283-318-388 133-150-183 283-318-388 Pa 0 (direct blow) Single phase induction motor kW 0.011 0.015 0.020 PP Honey comb ø 12.7(1/2") mm(in) ø 6.35(1/4") mm(in) O.D. ø32(1-1/4") O.D. ø32(1-1/4") O.D. ø32(1-1/4") dB(A) 28-31-35 28-31-37 29-33-38 Note: ❇ 1 Cooling/Heating capacity indicates the maximum value at operation under the following condition. Cooling : Indoor 27˚C(80.6˚F)DB/19˚C(66.2˚F)WB,Outdoor 35˚C(95˚F)DB Heating : Indoor 20˚C(68˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB ❇2 External dimension/ net weight are shown in , and airflow rate/noise level are in (low-middle2-middle1-high). ❇3 It is measured in anechoic room. 0.020 O.D. ø32(1-1/4") 30-34-39 External Dimensions PLFY-P20,25,32,40VCM-E 570 335 570 ø100 3-ø2.8hole Burring hole 25 ø73.4 Cut out hole 56 Detail drawing of fresh air intake hole 57 15~37 87 31 420 530 Suspension bolt pitch Suspension bolt pitch 576~620 Ceiling hole 15~37 Unit : mm Fresh air intake 2 Drain pipe VP-25 connection (O.D.ø32) 199 352 335 576~620 Ceiling hole 202 230 15~37 17 15~37 Wiring entry Suspension bolt M10 or W3/8 Ceiling surface 48 182 208 235 193 93 Ceiling surface 0 20 +5 Grille Terminal block 27 38~58 0˚ 12 12 0˚ 118 121 66 1 650 Suspension bolt lower edge 301 Air outlet hole Brand label 55 35 Grille V/M Drain hole 377 Auto vane Air intake hole 301 Air outlet hole 650 V/M Models V/M V/M Air intake grille Vane motor 35 55 377 Air intake hole 41 PLFY-P20VCM-E PLFY-P25VCM-E PLFY-P32VCM-E PLFY-P40VCM-E 1 Refrigerant pipe (6.35mm dia.) flared connection 1/4F 2 Refrigerant pipe (12.7mm dia.) flared connection 1/2F INDOOR UNIT Specifications & External Dimensions PLFY-P VAM-E Specifications PLFY-P32VAM-E PLFY-P40VAM-E Power source ❇1 ❇1 Cooling capacity ❇2 ❇2 ❇1 Heating capacity ❇1 ❇1 Cooling Power consumption Heating Cooling Current Heating External finish(Munsel No.) kW BTU/h kW kcal/h kW kcal/h BTU/h kW kW A A Dimension H x W x D ❇ 3 mm in. kg(lbs.) ❇3 Net weight Heat exchanger Type Fan Airflow rate ❇3 (Low-Mid2-Mid1-High) 4.5 15,400 4.7 4,000 5.0 4,300 17,100 PLFY-P100VAM-E 9.0 30,700 9.3 8,000 10.0 8,600 34,100 0.18 0.18 0.86 0.86 PLFY-P125VAM-E 11.2 38,200 11.6 10,000 12.5 10,800 42,700 0.30 0.30 1.43 1.43 14.0 47,800 14.5 12,500 16.0 13,800 54,600 0.34 0.34 1.64 1.64 298(30) x 840(950) x 840(950) 11-3/4"<1-3/16"> x 33-1/8"<37-7/16"> x 33-1/8"<37-7/16"> 32<5>(71<12>) 11-12-13-14 12-13-14-16 14-15-16-18 16-18-20-22 19-22-25-27 21-24-27-29 183-200-217-233 388-424-459-494 200-217-233-267 424-459-494-565 233-250-267-300 494-530-565-636 267-300-333-367 565-636-706-777 317-367-417-450 671-777-883-953 350-400-450-483 742-848-953-1024 Pa 0 Single phase induction motor kW 0.070 0.120 PP Honeycomb mm(in.) ø12.7 Liquid mm(in.) ø6.35 (1/4") (Flare) Drain pipe diameter Noise level (Lo-Mid2-Mid1-Hi) ❇3 ❇4 5.6 19,100 5.8 5,000 6.3 5,400 21,500 L/s cfm Gas (Flare) PLFY-P80VAM-E PLFY-P63VAM-E ~ 220-240V 50Hz / ~ 220V 60Hz 7.1 24,200 7.3 6,300 8.0 6,900 27,300 0.14 0.16 0.14 0.16 0.68 0.78 0.68 0.78 Panel : 0.70Y 8.59/0.97 258<30>x 840<950> x 840<950> 10-3/16"<1-3/16"> x 33-1/8"<37-7/16"> x 33-1/8"<37-7/16"> 22<5>(49<12>) 24<5>(53<12>) Cross fin (Aluminum plate fin and copper tube) Turbo fan 3.6 12,300 3.7 3,150 4.0 3,400 13,600 0.12 0.12 0.59 0.59 m3/min External static pressure Type Motor Output Air filter Refrigerant pipe diameter PLFY-P50VAM-E dB(A) ø 12.7(1/2") / ø 15.88(5/8") (Compatible) ø 6.35(1/4") / ø 9.52(3/8") (Compatible) (1/2") 27-28-29-31 27-28-30-32 ø 15.88 (5/8")/ ø 19.05(3/4") (Compatible) ø 15.88(5/8") ø 9.52 (3/8") O.D. ø32 (VP-25) 28-29-31-33 35-38-41-43 33-36-39-41 30-32-35-37 Note: ❇ 1 Cooling/Heating capacity indicates the maximum value at operation under the following condition. Cooling : Indoor 27 ˚C(80.6˚F) DB/19˚C(66.2˚F) WB,Outdoor 35˚C(95˚F)DB Heating : Indoor 20˚C(68˚F) DB,Outdoor 7˚C(44.6˚F) DB/6˚C(42.8˚F) WB ❇ 2 Cooling capacity indicates the maximum value at operation under the following condition. Cooling : Indoor 27˚C(80.6˚F)DB/19.5˚C(67.1˚F)WB,Outdoor 35˚C(95˚F)DB (WR2: water 30˚C(80˚F)) Heating : Indoor 21˚C(69.8˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB (WR2: water 20˚C(68˚F)) ❇ 3 External dimension/ net weight are shown in , and airflow rate/noise level are in (low-middle2-middle1-high). ❇ 4 It is measured in anechoic room. External Dimensions PLFY-P32,40,50,63,80,100,125VAM-E 20~45 159 20~45 810 Suspension bolt pitch Fresh air intake 16 197 159 120˚ 840 120˚ 158 20~45 3 - ø2.8 Burring hole ø125 Suspension bolt M10 or W3/8 ø 100 (Cut out hole) 1 Feeding hole (Drain pump) 286 374 60 Branch duct hole 159 89 Detail drawing of fresh air intake hole 98 192 ø 150 860~910 Ceiling hole Terminal block 840 14 - ø 2.8 Burring hole Suspension bolt pitch 605 Branch duct hole 350 ø 175 167 155 159 130 70˚ 100 90 100 100 90 Unit : mm Ceiling hole 860~910 20~45 Branch duct hole (Cut out hole) Drain pipe VP-25connection (O.D.ø 32) 2 B Grille Drain hole 135 Air intake grille 190 Ceiling surface 577 Air intake hole 30 Control wire entry 17 105 Power line entry +5 0 140 Suspension bolt lower edge 50~70 170 A Ceiling surface PLFY-P63VAM-E PLFY-P80VAM-E PLFY-P100VAM-E PLFY-P125VAM-E A B ø 12.7 ø 6.35(R410A) ø 12.7(R410A) 241 ø 9.52(R407C,R22) ø15.88(R407C,R22) 258 ø 15.88 ø 9.52 ø 15.88(R410A) 281 ø19.05(R407C,R22) 577 Air intake hole ➁ Gas Pipe 298 Auto vane 411 Air outlet hole ø 6.35 M 77 PLFY-P50VAM-E ➀ Liquid Pipe 51 Models PLFY-P32VAM-E PLFY-P40VAM-E M 950 High efficiency filter & Fresh air intake casement (option) 17 +50 M M 411 Air outlet hole 950 Vane motor 77 51 42 INDOOR UNIT Specifications & External Dimensions PLFY-P VLMD-E Specifications PLFY-P20VLMD-E Power source ❇1 ❇1 ❇2 ❇2 ❇1 ❇1 ❇1 Cooling capacity Heating capacity Cooling Heating Cooling Current Heating External finish(Munsel No.) Power consumption Dimension H x W x D mm in. kg(lbs.) ❇ 3 ❇ 3 Net weight kW BTU/h kW kcal/h kW kcal/h BTU/h kW kW A A Motor External static pressure Type Pa Output kW PLFY-P40VLMD-E 11-7/16"<13/16"> x30-9/16"<42-9/16"> x 25"<28"> 24 <6.5>(53<15>) 23 <6.5>(51<15>) Cross fin m 3/min L/s cfm Airflow rate (Lo-Mid-Hi) PLFY-P32VLMD-E ~ 220-240V 50Hz / ~ 220-230V 60Hz 2.2 2.8 3.6 4.5 7,500 9,600 12,300 15,400 2.3 2.9 3.7 4.7 2,500 3,150 4,000 2,000 2.5 3.2 4.0 5.0 2,200 2,800 3,400 4,300 8,500 10,900 13,600 17,100 0.072 / 0.075 0.072 / 0.075 0.072 / 0.075 0.081 / 0.085 0.065 / 0.069 0.065 / 0.069 0.065 / 0.069 0.074 / 0.079 0.36 / 0.37 0.36 / 0.37 0.36 / 0.37 0.40 / 0.42 0.30 / 0.32 0.30 / 0.32 0.30 / 0.32 0.34 / 0.37 Unit: Galvanizing Decoration Panel: ABS (0.7Y 8.59/0.97) Service Panel: Galvanizing (0.7Y 8.59/0.97) 290<20> x 776<1,080> x 634<710> Heat exchanger Type Fan PLFY-P25VLMD-E Turbo fan✕1 6.5-8.0-9.5 108-133-158 7.0-8.5-10.5 117-142-175 230-283-335 247-300-371 0 Single phase induction motor 0.015 PP honeycomb fabric (long life filter) Air filter Refrigerant pipe diameter Gas(Flare) mm(in.) ø 12.7(1/2") Liquid(Flare) mm(in.) ø 6.35(1/4") Unit drain pipe I.D.32 (1-1/4inch) 27-30-33 28-31-34 Drain pipe diameter Noise level (Lo-Mid-Hi) dB(A) 220V,240V 230V ❇4 dB(A) 29-33-36 30-34-37 PLFY-P50VLMD-E PLFY-P63VLMD-E PLFY-P80VLMD-E PLFY-P100VLMD-E PLFY-P125VLMD-E Power source ❇1 ❇1 ❇2 ❇2 ❇1 ❇1 ❇1 Cooling capacity Heating capacity Cooling Heating Cooling Current Heating External finish(Munsel No.) Power consumption Dimension H x W x D ❇ 3 ❇ 3 Net weight Heat exchanger Type Fan Motor kW BTU/h kW kcal/h kW kcal/h BTU/h kW kW A A ~ 220-240V 50Hz / ~ 220-230V 60Hz 11.2 7.1 9.0 5.6 19,100 24,200 30,700 38,200 5.8 7.3 9.3 11.6 6,300 8,000 10,000 5,000 12.5 8.0 10.0 6.3 5,400 6,900 8,600 10,800 21,500 27,300 34,100 42,700 0.101 / 0.105 0.147 / 0.156 0.157 / 0.186 0.082 / 0.086 0.094 / 0.099 0.140 / 0.150 0.150 / 0.180 0.075 / 0.080 0.72 / 0.74 0.75 / 0.88 0.49 / 0.51 0.41 / 0.43 0.43 / 0.46 0.66 / 0.69 0.69 / 0.83 0.35 / 0.38 Unit: Galvanizing Decoration Panel: ABS (0.7Y 8.59/0.97) Service Panel: Galvanizing mm 290<20> x 946<1,250> x 634<710> 290<20> x 1,446<1,750> x 634<710> 290<20> x 1,708<2,010>x 606<710> in. 11-7/16"<13/16"> x 37-1/4"<49-1/4"> x 25"< 28"> 11-7/16"<13/16"> x 56-15/16"<68-15/16"> x 25"< 28"> 11-7/16"<13/16"> x 67-1/4"<79-3/16"> x 23-7/8"< 28"> kg(ibs.) 27 <7.5>(60<17>) 28 <7.5>(62<17>) 44 <12.5>(98<28>) 47 <12.5>(104<28>) 56 <13.0>(124<29>) Cross fin Airflow rate (P50~P100:Lo-Mid-Hi) (P125:Lo-Mid2-Mid1-Hi) m 3/min L/s cfm External static pressure Type Pa Output kW Turbo fan✕1 10.0-13.0-15.5 9.0-11.0-12.5 150-183-208 167-217-258 318-388-441 353-459-547 0.020 Gas(Flare) mm(in.) ø 12.7(1/2")[R410A] ø 15.88(5/8") [R22,R407C] Liquid(Flare) mm(in.) ø 6.35(1/4")[R410A] ø 9.52(3/8")[R22,R407C] Drain pipe diameter Noise level (Lo-Mid-Hi) Turbo fan✕2 15.5-18.5-22.0 17.5-21.0-25.0 258-308-367 292-350-417 547-653-777 0 Single phase induction motor 0.020 (at 240V) 0.030 (at 240V) ❇4 220V,240V 230V dB(A) dB(A) 31-34-37 32-35-38 Sirocco fan✕4 24.0-27.0-30.0-33.0 400-450-500-550 848-953-1,059-1,165 0.078✕2(at 240V) Synthetic fiber unwoven cloth filter (long life) ø 15.88(5/8") [R410A] ø 19.05(3/4") [R22,R407C] ø 15.88(5/8") ø 9.52(3/8") Unit drain pipe I.D.32 (1-1/4inch) 36-39-42 33-36-39 32-37-39 34-37-40 33-38-40 37-41-43 Note: ❇ 1 Cooling/Heating capacity indicates the maximum value at operation under the following condition. Cooling : Indoor 27˚C(80.6˚F)DB/19˚C(66.2˚F)WB,Outdoor 35˚C(95˚F)DB Heating : Indoor 20˚C(68˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB ❇ 2 Cooling capacity indicates the maximum value at operation under the following condition. Cooling : Indoor 27˚C(80.6˚F)DB/19.5˚C(97.1˚F)WB,Outdoor 35˚C(95˚F)DB (WR2: water 30˚C(80˚F)) Heating : Indoor 21˚C(69.8˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB (WR2: water 20˚C(68˚F)) ❇ 3 The figure in < > indicates panel's ❇ 4 It is measured in anechoic room. 43 618-742-883 PP honeycomb fabric (long life filter) Air filter Refrigerant pipe diameter 14.0 47,800 14.5 12,500 16.0 13,800 54,600 0.28 / 0.28 0.27 / 0.27 1.35 / 1.35 1.33 / 1.33 (0.7Y 8.59/0.97) 40-42-44-46 (Lo-Mid2-Mid1-Hi) INDOOR UNIT Specifications & External Dimensions PLFY-P VLMD-E External Dimensions Unit : mm 146 70 H 670 ø12.7 ø15.88 ø6.35 ø9.52 Liquid pipe:HP Model 63·80 Gas pipe:LP Liquid pipe:HP ø15.88 ø9.52 Model 100 Gas pipe:LP ø15.88 ø19.05 ø9.52 Drain hose VP-25 (accessory) Liquid pipe:HP Terminal bed(Power source) Terminal bed(Transmission) 108 D(Lifting Bolt Pitch) 108 B Terminal box Branch duct Fx110 knock out hole (both side)(Note:2) 68 D(Lifting bolt pitch) 574 (Lifting Bolt Pitch) G-ø2.9 Mounting hole 4-ø2.9 Mounting hole 2 1 497 3 221 146 70 Control box 122 290 266 202 73 20 B 20 45 216 45 60 52 E 34 222 F 110 190 197 159 240 68 634 C More Than 350 Gas pipe:LP 190 Model 50 48 Model 20·25·32·40 574 Gas pipe:LP ø12.7 Liquid pipe:HP ø6.35 634 507 Note: 1.Use M10 screw for the lifing bolt (field supply). 2.It is available to connect the branch duct on right and left side both. 3.On Model :50, 100, you would use flare nut packed with the Indoor Unit, when connnecting the Outdoor Unit for R407C, R22. 4.In order to increase the strength of the flare nut, the size of some of them has been increased. 48 PLFY-P20, 25, 32, 40, 50, 63, 80, 100VLMD-E 20 20 20 670 Air filter Drain hole Water filling port Fresh air intake 240x45 knock out hole Standard center panel A 300mm or less Model F G H(Liquid) H(Gas) E D C B A PLFY-P20VLMD-E PLFY-P25VLMD-E CMP-40VLW-B 1080 1040 776 824 388 17 27 PLFY-P32VLMD-E 217.5✕2 6 =435 PLFY-P40VLMD-E PLFY-P50VLMD-E CMP-63VLW-B 1250 1210 946 994 473 PLFY-P63VLMD-E 22 29 PLFY-P80VLMD-E 188.5✕4 CMP-100VLW-B 1750 1710 1446 1494 723 =754 10 36 22 PLFY-P100VLMD-E 583mmMAX 710 3 Note: 1.Use M10 screw for the lifting bolt (field supply). 2.On this model, you would use flare nut packed with the Indoor Unit, when connnecting the Outdoor Unit for R407C, R22. 3.In order to increase the strength of theflare nut, the size of some of them has been increased. 48 PLFY-P125VLMD-E 170mm ± 5mm(Actual Length) 2 606 670 574 A A(Liquid) A(Gas) 22 36 Model PLFY-P125VLMD-E 1 ø15.88 ø19.05 ø9.52 48 Gas pipe:LP Liquid pipe:HP Drain hose VP-25 (accessory) 3 107 1756 107 Water filling port 1970 Fresh air intake ø150 knock out hole 1756(Lifting bolt pitch) 127 303 338~353 More than 350 290 155 192 235 90 1970(Ceiling opening) 20 20 45 Terminal box 222 Air filter 70 Control box 4-ø2.8Mounting hole 4-ø2.9Mounting hole 20 333 670(Ceiling opening) Drain hole 20 ø224 255 38 2 ˚ 90˚ 145 ˚ 2 181 ø17 1 3 Terminal bed (Transmission) 856 45˚ Terminal bed (Power source) 127 1708 90 574(Lifting bolt pitch) 68 606 476 70 178 106 68 Branch duct ø200 knock out hole (both side) 20 2010 300mm or less 710 600mm Max 170mm±5mm(Actual length) 3 Standard center panel (CMP-125VLW-B) 44 INDOOR UNIT Specifications & External Dimensions PMFY-P VBM-E Specifications PMFY-P20VBM-E ❇1 ❇1 ❇2 ❇2 ❇1 ❇1 ❇1 Cooling Heating Cooling Heating Cooling capacity Heating capacity Power consumption Current kW BTU/h kW kcal/h kW kcal/h BTU/h kW kW A A External finish ❇3 Dimension H x W x D Net weight ❇ 3 Heat exchanger Type mm(in.) kg(lbs.) Fan m 3 /min L/s cfm ❇3 Airflow rate (Low-Mid2-Mid1-High) External static pressure Type Output Motor Gas 0 kW Single phase induction motor 0.028 PP Honeycomb fabric mm(in.) (Flare) Liquid PMFY-P40VBM-E ø 12.7(1/2") ø 6.35(1/4") mm(in.) (Flare) Drain pipe diameter Noise level (Low-Mid2-Mid1-High) ❇ 4 PMFY-P32VBM-E Pa Air filter Refrigerant pipe diameter PMFY-P25VBM-E ~220-240V 50Hz / ~ 220V 60Hz 4.5 2.2 2.8 3.6 7,500 9,600 12,300 15,400 2.3 2.9 3.7 4.7 2,000 2,500 3,150 4,000 5.0 2.5 3.2 4.0 2,200 2,800 3,400 4,300 8,500 10,900 13,600 17,100 0.054 0.042 0.044 0.054 0.042 0.044 0.26 0.20 0.21 0.26 0.20 0.21 Panel : 0.98Y8.99/0.63 230<30> x 812<1,000> x 395<470> (9-1/16"<1-3/16" >x 32"<39-3/8"> x 15-9/16"<18-9/16">) 14 <3.0> (31<7>) Cross fin (Aluminum plate fin and copper tube) Line flow fan ✕ 1 6.5-7.2-8.0-8.7 7.7-8.7-9.7-10.7 7.3-8.0-8.6-9.3 108-120-133-145 122-133-143-155 128-145-162-178 230-254-283-307 258-283-304-328 272-307-343-378 Power source O.D. ø25 (VP-20) dB(A) 27-30-33-35 33-35-37-39 32-34-36-37 Note: ❇ 1 Cooling/Heating capacity indicates the maximum value at operation under the following condition. Cooling : Indoor 27˚C(80.6˚F)DB/19˚C(66.2˚F)WB,Outdoor 35˚C(95˚F)DB Heating : Indoor 20˚C(68˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB ❇ 2 Cooling capacity indicates the maximum value at operation under the following condition. Cooling : Indoor 27˚C(80.6˚F)DB/19.5˚C(67.1˚F)WB,Outdoor 35˚C(95˚F)DB (WR2: water 30˚C(80˚F)) Heating : Indoor 21˚C(69.8˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB (WR2: water 20˚C(68˚F)) ❇3 External dimension / net weight are shown in , and airflow rate/noise level are in (low-middle2-middle1-high). ❇4 It is measured in anechoic room. External Dimensions PMFY-P20,25,32,40VBM-E Unit : mm Top 1000 outer side of grille 960 seiling opening 811 suspension bolt pitch 759 20 20 17.5 28 45 PVC pipe:VP-20[OD ø25(1')] Detail drawing of fresh air intake hole 247 69 17.5 4-ø2.8 Burring hole ø100 28 45 OD ø12.7(1/2") outer line of grille Knock out 812 250 759 288.5 Terminal block for power supply elect box 108 ø50 ( 56) Right side drain pan 1000 outer side of grille 40 Installation space required around indoor unit 470 ceiling panel suspension bolt(M10 or W3/8) Panel(grille):PMP-40BM 230 110 200 60 600 outer side of grille 200 Fresh air intake hole Terminal biock for transmission 110 Front 235 or more (10) 230 198 Drainage pipe PVC pipe:VP-20[OD ø25] Lower view 45 OD ø6.35(1/4") Gas pipe center of unit ceiling panel drain pan same line OD ø43 Liquid pipe 53 Air outlet(lower) (96) Left side pipe cover Drainage piping 43 20 ceiling opening 340 suspension bolt pitch 46 (20) 176 96 Refrigerant pipe(liquid) OD ø6.35 20 Refrigerant piping 2 141 20 74.5 26 2 ø1 Refrigerant pipe(gas) OD ø12.7 395 302 254 430 470 outer side of grille 20 74.5 26 mounting plate 30 Panel(grille):PMP-40BM INDOOR UNIT Specifications & External Dimensions New PEFY-P VMR-E-L/R Specifications PEFY-P20VMR-E-L/R ❇1 ❇1 ❇2 ❇2 ❇1 ❇1 ❇1 Cooling Heating Cooling Heating Cooling capacity Heating capacity Power consumption Current kW BTU/h kW kcal/h kW kcal/h BTU/h kW 2.2 7,500 2.3 2,000 2.5 2,200 8,500 0.06/0.06 0.06/0.06 0.29/0.29 0.29/0.29 kW A A External finish mm(in.) kg(lbs.) Dimension H x W x D Net weight ❇ 3 Heat exchanger Type Fan Airflow rate (Low-Mid-High) m 3 /min ❇3 External static pressure Motor PEFY-P25VMR-E-L/R 3.6 12,300 3.7 3,150 4.0 3,400 13,600 0.07/0.08 0.07/0.08 0.34/0.38 0.34/0.38 4.8-5.8-7.9 4.8-5.8-9.3 Pa Type Output PEFY-P32VMR-E-L/R 1-phase 220/230/240 V 50Hz 220/230V 60Hz 2.8 9,600 2.9 2,500 3.2 2,800 10,900 0.06/0.06 0.06/0.06 0.29/0.29 0.29/0.29 Galvanized 292 x 640 x 580 18 (40) Cross fin (Aluminum fin and copper tube) Sirocco fan ✕ 1 Power source 5 1-phase induction motor kW Air filter Refrigerant pipe diameter Gas(Flare) Liquid(Flare) Drain pipe diameter Noise level (Low-Mid2-Mid1-High) ❇4 220V 230V 240V 0.018 PP Honeycomb fabric (washable) mm(in.) ø 6.35(1/4") mm(in.) ø 12.7(1/2") O.D. 26(1-1/32) 0.023 20-25-30 21-26-32 22-27-30 dB(A) 20-25-33 21-26-35 22-27-33 Note: ❇ 1 Cooling/Heating capacity indicates the maximum value at operation under the following condition. Cooling: Indoor 27˚C (81˚F) DB/19˚C (66˚F) WB, Outdoor 35˚C (95˚F) DB Heating: Indoor 20˚C (68˚F) DB, Outdoor 7˚C (45˚F)DB/6˚C (43˚F) WB ❇ 2 Cooling capacity indicates the maximum value at operation under the following condition. Cooling : Indoor 27˚C(80.6˚F)DB/19.5˚C(67.1˚F)WB,Outdoor 35˚C(95˚F)DB (WR2: water 30˚C(80˚F)) Heating : Indoor 21˚C(69.8˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB (WR2: water 20˚C(68˚F)) ❇3 The external static pressure is set to 100Pa (at 220V) / 150Pa (at 230, 240V) at factory shipment. ❇4 Measured in anechoic room. Noise levels of the unit with a rear air inlet. (Noise levels are higher for the unit with a bottom air inlet.) External Dimensions PEFY-P20,25,32VMR-E-L/R Unit : mm Right side Note 1. Use M10 screw for the suspension bolt (field supply). 50mm or below of clearance between the Indoor unit top and the end of the suspension bolt will make maintenance of the Indoor heat exchanger easier. 2. Access door of 450mm x 450mm at the ceiling under the drain pan should be designed for heat exchanger cleaning and maintenance. 3. This drawing shows the left piping specification. The symmetry shows the right piping specification. Model name: PEFY-P20 · 25 · 32VMR-E-L PEFY-P20 · 25 · 32VMR-E-R 4. Period cleaning of drain pan will prevent water overflowing. Gradient piping design is needed for water draining. 5. The inlet direction can be changed between rear inlet and bottom inlet. Keep the inlet space between the ceiling and the unit in case of bottom inlet. 15 Air outlet 100 62 25 Required space for service and maintenance (Note 2) 23 Control box Left side Suspension bolt outlet (Note 1) 439 (Suspension bolt pitch) 105 250 580 (In case of rear inlet) 30 15 500 150 28 50 Rear air inlet Make the access door at the appointed position properly for service maintenance. 3 Bottom plate Access door 113 148 Bottom air inlet Insulation material Ceiling surface More than 20mm 2x2-ø3 Terminal bed (Power source) Hose band 450 450 50~ 25 1 100 2 Terminal bed (M-Net Transmission) Drain pan 150 50~ 300 25 570 (In case of bottom inlet) 275 300 (In case of bottom inlet) 292 (In case of rear inlet) 50 or below Suspension bolt hole More than 20mm 80 Air filter 622 50x9=450 480 Rear air inlet 50 630 584 (Suspension bolt pitch) 530 2x10-ø3 Adhesion Rigid vinyl drain pipe Refrigerant pipe (gas) brazed Insulation material or drain pan Urethane foam Drain hose (accessory) 150 Do not leave space. ø12.7·································➀ Refrigerant pipe (liquid) brazed ø6.35·································➁ Drain pipe connection diameter VP20(dia. 26mm) ·············➂ 46 INDOOR UNIT Specifications & External Dimensions New PEFY-P VMS-E Specifications PEFY-P20VMS-E PEFY-P25VMS-E PEFY-P32VMS-E PEFY-P40VMS-E PEFY-P50VMS-E PEFY-P63VMS-E Power source Cooling capacity ❇1 ❇1 Heating capacity Power input Current Temperature set range Remote controller Fan ❇2 Type x Quantity External static press Motor type Motor output Airflow rate(Low-Mid-High) External finish External dimension HxWxD Net weight R410A Refrigerant piping Liquid R407C,R22 diameter Gas R410A R407C,R22 Drain piping diameter Noise level (Low-Mid-High) (mesured in anechoic room) Air filter Connectable outdoor unit Heat exchanger kW kW kW A ˚C(˚F) Pa kW m3/min mm In. kg mm(in.) mm(in.) mm(in.) mm(in.) mm(in.) 1-phase 220-240V 50Hz 1-phase 220-230V 60Hz 3.6 4.5 5.6 7.1 5.0 6.3 8.0 4.0 0.08 0.08 0.06 0.09 0.07 0.11 0.09 0.13 0.11 0.14 0.12 0.06 0.39 0.39 0.28 0.44 0.33 0.53 0.42 0.63 0.52 0.68 0.57 0.28 19 to 30 (67 to 86) 17 to 28 (63 to 83) 19 to 30 (67 to 86) 17 to 28 (63 to 83) 19 to 30 (67 to 86) 17 to 28 (63 to 83) 19 to 30 (67 to 86) 17 to 28 (63 to 83) 19 to 30 (67 to 86) 17 to 28 (63 to 83) 19 to 30 (67 to 86) 17 to 28 (63 to 83) Sirocco fan x 4 Sirocco fan x 3 5-15-35-50 DC brushless motor 0.096 12-14-16.5 6-7-8 7.5-8.5-10 8-9.5-11 9.5-11-13 Galvanized 200 x 1100 x 700 200 x 900 x 700 7-7/8 x 43-5/16 x 27-9/16 7-7/8 x 35-7/16 x 27-9/16 23 24 28 ø6.35(ø1/4) Brazed ø9.52(ø3/8) Brazed ø6.35(ø1/4) Brazed ø9.52(ø3/8) Brazed ø9.52(ø3/8) Brazed ø6.35(ø1/4) Brazed ø12.7(ø1/2) Brazed ø15.88(ø5/8) Brazed ø12.7(ø1/2) Brazed ø12.7(ø1/2) Brazed ø15.88(ø5/8) Brazed ø15.88(ø5/8) Brazed O.D. 32(1-9/32) 2.2 2.5 2.8 3.2 dB 22-25-27 25-28-30 30-32-35 28-30-33 30-33-36 PP Honeycomb fabric (washable) R410A, R407C, R22 CITY MULTI Cross fin(Aluminium fin and copper tube) Note: ❇ 1.Cooling/Heating capacity indicates the maximum value at operation under the following condition. Indoor : 27˚CD.B./19˚CW.B. (81˚FD.B. / 66˚FW.B.) Outdoor : 35˚CD.B. (95˚FD.B. ) Indoor : 20˚CD.B. (68˚FD.B.) Outdoor : 7˚CD.B. / 6˚CW.B. (45˚FD.B. / 43˚FW.B.) Pipe length : 7.5m (24-9/16ft) Height difference : 0m (0ft) ❇ 2.The external static pressure is set to 15 Pa at factory shipment. External Dimensions PEFY-P20,25,32,40,50,63VMS-E Unit : mm 157.5 37 100 20 12 37 157.5 37 100 37 Access door 88 88 20 12 777 50 G 50 More than 20mm More than 20mm Ceiling surface Access door Make the access door at the appointed position properly for service maintenance. Air filter Less than 300mm 88 175mm -+ 5 mm (Actual length) 20 12 700 677 Drain pipe Drainpump (O.D.ø32) 270 24-ø2.9 Model:P63(Note3) Drain hose (I.D.ø32) 48 102 170 200 10 116 Model PEFY-P20,25,32,40VMS-E 70 270 Terminal bed(Power source) Drain pipe(O.D.ø32) (Spontaneous draining) Terminal bed(Transmission) A B C D E F G 900 952 998 860 9 800 1000 1100 1152 1198 1060 11 1000 1200 PEFY-P50VMS-E PEFY-P63VMS-E 100 20 12 23 625(Suspension bolt pitch) 23 150(Duct) 23 100 25 20-ø2.9 Air filter Suspension bolt hole 4-14 X 30 Slot Knockout hole ø27 (Power source wiring) Control box Knockout hole ø27 (Transmission wiring) 90 49 2 X 2-ø2.9 1 Refrigerant piping brazing connection (gas) 47 Air filter 88 100 20 30 100 57 25 10 2 X E-ø2.9 2 Refrigerant piping brazing connection (liquid) 1060 100 X 9=900 860 100 X 7=700 Air inlet 450 n 300 tha re Mo Required space for service and maintenance 50~ 4 150 50 100 Air outlet A B (Suspension bolt pitch) C D (Duct) 100 X (E-1)=F Note2 1Gas pipe ø12.7 ✻1 ✻2 ø12.7 ø15.88 ø15.88 2 Liquid pipe ø6.35 ✻1 ✻2 ø6.35 ø9.52 ø9.52 Note 1. Use M10 screw for the Suspension bolt (field supply). 2. Keep the service space for the maintenance at the bottom. 3. This chart indicates for PEFY-P20~50VMS-E models, which has 3 fans. PEFY-P63VMS-E model have 4 fans. 4. In case of the inlet duct is used,remove the air filter(supply with the unit), then install the filter(field supply) at suction side. ✻1 : R410A outdoor unit ✻2 : R407C,R22 outdoor unit Less than 550mm 15 INDOOR UNIT Specifications & External Dimensions PEFY-P VML-E Specifications PEFY-P20VML-E Power source ❇1 ❇1 ❇2 ❇2 ❇1 ❇1 ❇1 Cooling capacity Heating capacity Cooling Heating Cooling Heating Power consumption (50/60Hz) Current 2.2 7,500 2.3 2,000 2.5 2,200 8,500 kW BTU/h kW kcal/h kW kcal/h BTU/h kW kW A A External finish Dimension H x W x D Net weight Heat exchanger 3 Motor m /min L/s Airflow rate (Lo-Mid-Hi) 80-97-132 170-205-279 cfm Pa External static pressure Type Output PEFY-P32VML-E 225 x 720 x 550 (8-7/8" x 28-3/8" x 21-11/16") 18 (40) Cross fin (Aluminum plate fin and copper tube) Sirocco fan ✕ 1 4.8-5.8-7.9 mm(in.) kg(lbs.) Type Fan PEFY-P25VML-E ~ 220-240V 50Hz / 60Hz 2.8 9,600 2.9 2,500 3.2 2,800 10,900 0.05/0.06 0.05/0.06 0.24/0.28 0.24/0.28 Galvanizing 3.6 12,300 3.7 3,150 4.0 3,400 13,600 0.07/0.09 0.07/0.09 0.32/0.42 0.32/0.42 4.8-5.8-9.5 80-97-158 170-205-335 5 Single phase induction motor 0.023 PP Honeycomb fabric (washable) kW Air filter mm(in.) Gas(Brazing) ø 12.7(1/2") Refrigerant pipe diameter ø 6.35(1/4") mm(in.) Liquid(Brazing) R1 (External thread) Drain pipe diameter Noise level (Lo-Mid-Hi) dB(A) 25-29-36 ❇5 Note: ❇ 1 Cooling/Heating capacity indicates the maximum value at operation under the following condition. Cooling : Indoor 27˚C(80.6˚F)DB/19˚C(66.2˚F)WB,Outdoor 35˚C(95˚F)DB Heating : Indoor 20˚C(68˚F)DB,Outdoor 7˚(44.6˚F)CDB/6˚C(42.8˚F)WB ❇ 2 Cooling capacity indicates the maximum value at operation under the following condition. Cooling : Indoor 27˚C(80.6˚F)DB/19.5˚C(67.1˚F)WB,Outdoor 35˚C(42.8˚F)DB (WR2: water 30˚C(80˚F)) Heating : Indoor 21˚C(69.8˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB (WR2: water 20˚C(68˚F)) ❇ 3 The external static pressure is set to 100Pa (at 220V) /150Pa (at 230, 240V) at factory shipment. ❇ 4 The value are that at 240V. ❇ 5 It is measured in anechoic room. 0.032 25-29-40 External Dimensions PEFY-P20,25,32VML-E Unit : mm The part air intake duct is attached. (✻3) (When the air intake duct is used) Note 1.Use M10 screw for the lifting bolt (field supply). 2.Keep the service space for the maintenance from the bottom when the heat exchanger is cleaned. 3.The direction of air intake can be changed from the bottom to the rear by attaching the bottom plate to the air intake side. 4.Drain Pan is changeable from right and left. 5.The dimension is changed, in case the optional long-life filter is attached. RearAir-Intake spec.:Depth is increased by 30mm(✻1) BottomAir-Intake spec.:Height is increased by 30mm(✻2) Lifting bolt 14 80 Control box 459 (Lifting bolt pitch) 582 Refrigerant piping brazing connection (gas ø12.7 copper tube):LP ··· 1 Refrigerant piping brazing connection (liquid ø6.35 copper tube):HP ··· 2 Drain piping connection R1 (External thread) ··· 3 42.5 55 65.5 204.5 550 (✻1) 510 2 1 148 30 15 2✕3-ø3 540 14 Air filter 13.5 23 80 15 50✕11=550 720 Air outlet 50 Air inlet 16 710 664 (Lifting bolt pitch) 610 12-ø3 Air inlet Air filter Terminal bed (Power source) Terminal bed (Transmission) 3 113 127 225 (✻2) 50 50 Bottom plate In case of rear inlet In case of bottom inlet Air filter Air inlet Bottom plate 48 INDOOR UNIT Specifications & External Dimensions PEFY-P VMM-E Specifications PEFY-P20VMM-E PEFY-P25VMM-E PEFY-P32VMM-E PEFY-P40VMM-E PEFY-P50VMM-E PEFY-P63VMM-E Power source Cooling capacity Heating capacity Power consumption (50Hz) Current ❇1 ❇1 ❇2 ❇2 ❇1 ❇1 ❇1 Cooling Heating Cooling Heating kW BTU/h kW kcal/h kW kcal/h BTU/h kW kW A A 2.2 7,500 2.3 2,000 2.5 2,200 8,500 ~220-240V 50Hz 3.6 4.5 15,400 12,300 4.7 3.7 4,000 3,150 4.0 5.0 3,400 4,300 13,600 17,100 0.17 0.19 0.17 0.19 0.92 0.81 0.81 0.92 Galvanizing 2.8 9,600 2.9 2,500 3.2 2,800 10,900 0.15 0.15 0.73 0.73 External finish Dimension H x W x D mm(in.) Net weight Heat exchanger Type kg(lbs.) m3/min Fan Airflow rate (Lo-Mid-Hi) External static pressure Type Output Air filter Motor Gas Refrigerant pipe diameter (Flare) Liquid (Flare) Drain pipe diameter Noise level (Lo-Mid-Hi) ❇3 L/s cfm Pa 295 x 815 x 700 (11-5/8 "x 32-1/8" x 27-9/16") 5.6 19,100 5.8 5,000 6.3 5,400 21,500 0.20 0.20 0.98 0.98 7.1 24,200 7.3 6,300 8.0 6,900 27,300 0.22 0.22 1.07 1.07 295 x 935 x 700 (11-5/8" x 36-13/16" x 27-9/16") 295 x 1,175 x 700 (11-5/8" x 46-5/16" x 27-9/16") 33(73) Cross fin (Aluminum plate fin and copper tube) Sirocco fan✕ 1 Sirocco fan✕ 2 6.0-7.2-8.5 100-120-142 212-254-300 kW 7.5-9.0-10.5 10.0-12.0-14.0 125-150-175 167-200-233 265-318-371 353-424-494 30/50/100 Single phase induction motor 0.075 PP Honeycomb fabric (washable) mm(in.) ø 12.7(1/2") mm(in.) ø 6.35(1/4") dB(A) 12.0-14.5-17.0 200-242-283 424-512-600 27-30-32 ø 12.7(1/2")[R410A] ø 15.88(5/8")[R22,R407C] ø 6.35(1/4")[R410A] ø 9.52(3/8")[R22,R407C] Cooling capacity Heating capacity Power consumption (50Hz) Current 8.0 27,300 8.3 7,100 9.0 7,700 30,700 9.0 30,700 9.3 8,000 10.0 8,600 34,100 0.25 0.25 1.15 1.15 External finish Dimension H x W x D mm(in.) Net weight Heat exchanger Type kg(lbs.) Fan Airflow rate (Lo-Hi) External static pressure Type Output Air filter Motor Gas Refrigerant pipe diameter (Flare) Liquid (Flare) Drain pipe diameter Noise level (Lo-Mid-Hi) ❇3 m3/min L/s cfm Pa kW mm(in.) 295 x 1,175 x 700 (11-5/8" x 46-5/16" x 27-9/16") 16.0 54,600 16.3 14,000 18.0 15,500 61,400 0.42 0.42 1.95 1.95 325 x 1,715 x 740 (12-13/16" x 67-9/16" x 29-3/16") 62(137) 65(144) 70(155) Cross fin (Aluminum plate fin and copper tube) Sirocco fan✕2 23.0-33.0 28.0-40.0 29.5-42.0 14.5-18.0-21.0 383-550 467-667 492-700 242-300-350 812-1165 989-1413 1042-1483 512-636-742 50/130 30/50/100 Single phase induction motor 0.280 0.200 0.078 PP Honeycomb fabric (washable) ø 15.88(5/8") [R410A] ø 15.88(5/8") ø 19.05(3/4") [R22,R407C] 42(93) mm(in.) dB(A) ~220-240V 50Hz 14.0 11.2 38,200 47,800 11.6 14.5 12,500 10,000 16.0 12.5 10,800 13,800 42,700 54,600 0.29 0.40 0.29 0.40 1.34 1.90 1.34 1.90 Galvanizing 325 x 1,415 x 740 (12-13/16" x 55-3/4" x 29-3/16") ø 9.52 (3/8") 32-36-39 R1 (External thread) 40-44 42-45 Note: ❇ 1 Cooling/Heating capacity indicates the maximum value at operation under the following condition. Cooling : Indoor 27˚C(80.6˚F)DB/19˚C(66.2˚F)WB,Outdoor 35˚C(95˚F)DB Heating : Indoor 20˚C(68˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB ❇ 2 Cooling capacity indicates the maximum value at operation under the following condition. Cooling : Indoor 27˚C(80.6˚F)DB/19.5˚C(67.1˚F)WB,Outdoor 35˚C(95˚F)DB (WR2: water 30˚C(80˚F)) Heating : Indoor 21˚C(69.8˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB (WR2: water 20˚C(68˚F)) ❇ 3 It is measured in anechoic room. 49 ø 15.88(5/8") ø 9.52(3/8") 31-35-38 PEFY-P71VMM-E PEFY-P80VMM-E PEFY-P100VMM-E PEFY-P125VMM-E PEFY-P140VMM-E kW BTU/h kW kcal/h kW kcal/h BTU/h kW kW A A 13.5-16.2-19.0 225-270-317 477-572-671 0.078 R1 (External thread) 28-32-35 31-34-37 Power source ❇1 ❇1 ❇2 ❇2 ❇1 ❇1 ❇1 Cooling Heating Cooling Heating 42(93) 27(60) 42-45 INDOOR UNIT Specifications & External Dimensions PEFY-P VMM-E External Dimensions Service space:500mm or more 1 282 288 256 176 Air inlet 355 365˜465 159 56 18 B 81 A 44 75 243 10 2 C E 13 D 30 10-ø3(P20/25/32/40/50) 12-ø3(P63/71/80) 6 277 45 80 85 227 24 10 81 30 61 40 3.5 21 In case of rear inlet 640 4 179 30 81 Lifting bolt hole 13 35 P63,71,80 D E 710 684 830 804 109 P50 C - B (14X22) H(Liquid) H(Gas) F G 17 27 6.35 12.7 17 27 6.35 12.7 ✻1 6.35 ✻1 12.7 ✻1 22 ✻1 29 772 305 830 804 ✻2 9.52 ✻2 15.88 ✻2 22 ✻2 29 9.52 15.88 1012 280 290 1070 1044 22 29 A B 652 245 772 305 C 81 197 450 H Refrigerant piping flare connection (liquid øF copper tube):HP Refrigerant piping flare connection (gas øG copper tube) :LP Drain R1(External thread) Electrical parts box Drain Pump (Option) Drain Pipe (Option)···Flexible joint VP-25(I.D.ø32) Set Filter Model P20,25,32 P40 55 Access door 10-ø3(P20/25/32/40/50) 12-ø3(P63/71/80) A 10 Note: 1. On Model :50, you would use flare nut packed with the Indoor Unit, when connnecting the Outdoor Unit for R407C, R22. 2. In order to increase the strength of the flare nut, the size of some of them has been increased. 1 2 3 4 5 6 7 50˜150 29 450 Unit : mm 10 PEFY-P20,25,32,40,50,63,71,80VMM-E 5 7 3.5 Air outlet 3 Keep duct-work length 850mm or more. Be sure to apply the air filter (field supply) near the air inlet grille. In case of bottom inlet 10-ø3(P20/25/32/40/50) 12-ø3(P63/71/80) 7 10 Air outlet 40 15 10 176 256 81 C B 81 A Air inlet PEFY-P100,125,140VMM-E Service space:500mm or more 450 Access door 365˜465 323 308 2 44 282 319 279 181 Air inlet 13 E 75 D B 81 13 30 243 6 307 45 122 113 1 30 10 40 In case of rear inlet 4 169 35 3 25 53 20 680 C A 10 80 12-ø3 81 210 30 81 Lifting bolt hole (14X22) C D E F(Liquid) F(Gas) 370 1310 1284 22 36 470 1610 1584 22 36 140 Model A B P100·125 1252 360 P140 1552 460 5 7 3 Air outlet 3 Keep duct-work length 850mm or more. Be sure to apply the air filter (field supply) near the air inlet grille. In case of bottom inlet 282 Air outlet 12-ø3 10 7 15 40 181 279 Air inlet 10 3 4 5 6 7 (liquid ø9.52 copper tube):HP Refrigerant piping flare connection (gas ø15.88 copper tube):LP ø19.05 Drain 25A (male screw) Electrical parts box Drain Pump (Option) Set Drain Pipe (Option)···Flexible joint VP25(I.D. ø32) Filter 30 2 B 375 1 Refrigerant piping flare connection 12-ø3 A C 197 450 H 50˜150 29 55 81 10 Note: 1. On this model, you would use flare nut packed with the Indoor Unit, when connnecting the Outdoor Unit for R407C, R22. 2. In order to increase the strength of the flare nut, the size of some of them has been increased. 81 C B 81 A 50 INDOOR UNIT Specifications & External Dimensions PEFY-P VMH-E Specifications Power source Cooling capacity Heating capacity Power consumption (50/60Hz) Current ❇1 ❇1 ❇2 ❇2 ❇1 ❇1 ❇1 Cooling Heating Cooling Heating External finish Dimension H x W x D Net weight Heat exchanger Type Fan Airflow rate (Lo-Hi) External static 220V pressure ❇ 3 230, 240V Type Motor Output ❇4 Air filter (option) Gas (Flare) Refrigerant pipe diameter Liquid (Flare) Drain pipe diameter Noise level (Lo-Hi) 220V ❇ 5 230, 240V PEFY-P40VMH-E PEFY-P50VMH-E PEFY-P63VMH-E PEFY-P71VMH-E PEFY-P80VMH-E PEFY-P100VMH-E PEFY-P125VMH-E PEFY-P140VMH-E ~ 220-240V 50Hz /60Hz 16.0 9.0 11.2 14.0 8.0 4.5 5.6 kW 7.1 BTU/h 15,400 19,100 24,200 27,300 30,700 38,200 47,800 54,600 kW 9.3 11.6 14.5 16.3 8.3 4.7 5.8 7.3 8,000 7,100 4,000 5,000 kcal/h 10,000 12,500 14,000 6,300 10.0 18.0 12.5 16.0 9.0 5.0 6.3 kW 8.0 kcal/h 4,300 5,400 10,800 13,800 15,500 6,900 8,600 7,700 34,100 BTU/h 17,100 21,500 27,300 30,700 42,700 54,600 61,400 kW 0.32/0.40 0.48/0.58 0.48/0.59 0.19/0.23 0.24/0.30 0.26/0.33 kW 0.19/0.23 0.24/0.30 0.26/0.33 0.32/0.40 0.48/0.58 0.48/0.59 A 0.88/1.06 1.12/1.38 1.20/1.51 1.47/1.83 2.34/2.66 2.35/2.70 A 0.88/1.06 1.12/1.38 1.20/1.51 1.47/1.83 2.34/2.66 2.35/2.70 Galvanizing 380 x 1,000 x 900 380 x 1,200 x 900 mm 380 x 750 x 900 15" x 39-3/8" x 35-7/16" 15" x 47-1/4" x 35-7/16" 15" x 29-9/16" x 35-7/16" in. kg(lbs.) 50(111) 45(100) 44(98) 70(155) Cross fin (Aluminum plate fin and copper tube) Sirocco fan ✕ 1 Sirocco fan ✕ 2 m3/min 10.0-14.0 28.0-40.0 13.5-19.0 18.0-25.0 15.5-22.0 26.5-38.0 L/s 167-233 225-317 258-367 300-417 442-633 467-667 353-494 477-671 547-777 636-883 936-1342 989-1413 cfm Pa 50/100/200 Pa 100/150/200 Single phase induction motor 0.08 0.12 0.14 0.26 0.18 kW Synthethic fiber unwoven cloth filter(long life) 1 ø 15.88 (5/8") [R410A] mm(in.) ø 12.7 (1/2") ø 12.7 5( /2") [R410A] ø 15.88(5/8") ø 15.88 ( /8") [R22,R407C] ø 19.05 (3/4") [R22,R407C] 1/4") [R410A] ø 6.35( mm(in.) ø 6.35 (1/4") ø 9.52(3/8") ø 9.52 (3/8")[R22,R407C] 32 (1-1/4 inch) 32 (1-1/4 inch) 35-41 dB(A) 27-34 32-38 32-39 34-42 38-43 dB(A) 31-37 36-41 35-41 38-44 Note: ❇ 1 Cooling/Heating capacity indicates the maximum value at operation under the following condition. Cooling : Indoor 27˚C(80.6˚F)DB/19˚C(66.2˚F)WB,Outdoor 35˚C(95˚F)DB Heating : Indoor 20˚C(68˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB ❇ 2 Cooling capacity indicates the maximum value at operation under the following condition. Cooling : Indoor 27˚C(80.6˚F)DB/19.5˚C(67.1˚F)WB,Outdoor 35˚C(95˚F)DB (WR2: water 30˚C(80˚F)) Heating : Indoor 21˚C(69.8˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB (WR2: water 20˚C(68˚F)) ❇ 3 The external static pressure is set to 100Pa (at 220V) /150Pa (at 230, 240V) at factory shipment. ❇ 4 The value are that at 240V. ❇ 5 It is measured in anechoic room. External Dimensions Unit : mm PEFY-P40,50,63,71,80, 100,125,140VMH-E G-ø3 Air outlet Air inlet E A 50x(J-1)=K B (Lifting bolt pitch) C 50x(G-1)=H D J-ø3 Less than 300mm 170mm±5mm (Actual length) 50 50 Less than 550 mm 3 80 41 F 15 23 70 10 3 340 383 Lifting bolt 250 814 (Lifting bolt pitch) 904 Model:40~80 (Note3) 60 When installing the drain water lifting-up mech(option). 900 24 10 847 29 15 Drain hole (option) Control box Terminal box Terminal bed (Transmission) Keep duct-work length 850mm or more. Drain hole 51 1 92 200 343 387 77 328 250 380 94 50 50 50 50 41 25 30 45 17 Terminal bed (Power source) 130 50x5=250 50 340 2 Model P40VMH-E L K J A B C D E F G H 800 754 680 600 550 50 11 500 10 450 780 P50VMH-E 800 754 680 600 550 50 11 500 10 450 780 M ø12.7 ✻1 ø12.7 ✻2 ø15.88 P63VMH-E 800 754 680 600 550 50 11 500 10 450 780 ø15.88 P71·80VMH-E 1050 1004 930 850 800 25 17 800 15 700 1030 ø15.88 ✻1 ø15.88 P100·125 1250 1204 1130 1050 1000 25 21 1000 19 900 1230 ·140VMH-E ✻2 ø19.05 N ø6.35 ✻1 ø6.35 ✻2 ø9.52 ø9.52 ø9.52 ✻1 ø9.52 ✻2 ø9.52 P(Liquid) 17 ✻1 22 ✻2 22 22 22 ✻1 22 ✻2 22 P(Gas) 27 ✻1 29 ✻2 29 29 29 ✻1 36 ✻2 36 ✻1:R410A outdoor unit ✻2:R407C,R22 outdoor unit Note : 1. Use M10 screw for the lifting bolt (field supply). 2. Keep the service space for the maintenance from the bottom when the heat exchanger is cleaned. 3. This chart indicates for PEFY-P100·125·140VMH-E models, which have 2 fans. PEFY-P40·50·63·71·80 models have 1 fan. 4. Make sure to install the air filter(field supply) on the air intake side. In case field supplied air filter is used, attach it where the filter service is easily done. 5.On Model :50, 100, 125, 140, you would use flare nut packed with the Indoor Unit, when connnecting the Outdoor Unit for R407C, R22. 6.In order to increase the strength of the flare nut, the size of some of them has been increased. Refrigerant piping flare connection (gas M copper tube) : LP ··· ➀ Refrigerant piping flare connection (liquid N copper tube) : HP ··· ➁ Drain hose 32mm(1-1/4inch) (accessory) ··· ➂ P INDOOR UNIT Specifications & External Dimensions PEFY-P VMH-E Specifications PEFY-P200VMH-E PEFY-P250VMH-E Power source 3N ~ 380-415V 50Hz / 60Hz ❇ ❇ ❇ ❇ ❇ ❇ ❇ Cooling capacity Heating capacity 1 1 2 2 1 1 1 Cooling Heating Cooling Heating Power consumption (50/60Hz) Current External finish Dimension H x W x D Net weight Heat exchanger Type Fan 22.4 76,400 23.3 20,000 25.0 21,500 85,300 0.99/1.14 0.99/1.14 1.62/1.86 1.62/1.86 kW BTU/h kW kcal/h kW kcal/h BTU/h kW kW A A 28.0 95,500 29.1 25,000 31.5 27,100 107,500 1.23/1.41 1.23/1.41 2.0/2.3 2.0/2.3 Galvanizing 470 x 1,250 x 1,120 (18-9/16" x 49-1/4" x 44-1/8") 100 (221) Cross fin (Aluminum plate fin and copper tube) mm(in.) kg(lbs.) Sirocco fan ✕ 2 m 3/min L/s cfm Airflow rate External static pressure ❇5 Type Motor Output Air filter (option) 380V 400, 415V Pa Pa ❇6 kW 58.0 967 2048 72.0 1200 2543 110/220 130/260 3-phase induction motor 0.76 1.08 Synthethic fiber unwoven cloth filter(long life) Gas ø 19.05 (3/4") [R410A] ø 25.4 (1") [R22,R407C] mm(in.) (Brazing) Refrigerant pipe diameter Liquid mm(in.) (Brazing) ø 22.2 (7/8") [R410A] ø 28.58 (1-1/8") [R22,R407C] ø 9.52 (3/8") (R410A) ø 12.7 (1/2") (R22,R407C) 32 (1-1/4 inch) Drain pipe diameter 42(110Pa)/45(220Pa) 50(110Pa)/52(220Pa) dB(A) 44(130Pa)/47(260Pa) 52(130Pa)/54(260Pa) dB(A) Note: ❇1 Cooling/Heating capacity indicates the maximum value at operation under the following condition. ❇ 3 The external static pressure is set to 100Pa (at 220V) /150Pa (at 230, 240V) at factory shipment. Cooling : Indoor 27˚C(80.6˚F)DB/19˚C(66.2˚F)WB,Outdoor 35˚C(95˚F)DB ❇ 4 The value are that at 240V. Heating : Indoor 20˚C(68˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB ❇ 5 The external static pressure is set to 110Pa (at 380V) /130Pa (at 400, 415V) at factory shipment. ❇ 6 The value are that at 415V. ❇2 Cooling capacity indicates the maximum value at operation under the following condition. Cooling : Indoor 27˚C(80.6˚F)DB/19.5˚C(67.1˚F)WB,Outdoor 35˚C(95˚F)DB (WR2: water 30˚C(80˚F)) ❇ 7 It is measured in anechoic room. Heating : Indoor 21˚C(69.8˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB (WR2: water 20˚C(68˚F)) 380V 400, 415V ❇7 Noise level External Dimensions PEFY-P200, 250VMH-E Unit : mm 22-ø3 3 420 1100 50x20=1000 1326 (Lifting bolt pitch) 1372 50 100 15 10 Lifting bolt 1034 (Lifting bolt pitch) 1124 60 1120 1067 24 10 Note : 1. Use M10 screw for the lifting bolt (field supply). 2. Keep the service space for the maintenance from the bottom when the heat exchanger is cleaned. 3. Make sure to install the air filter(field supply)on the air intake side. In case field supplied air filter is used, attach it where the filter service is easily done. 4.On this model, you would use pipe packed with the Indoor Unit, when connnecting the Outdoor Unit for R407C, R22. Model A P200VMH-E ✻1 ø19.05 ✻1 ø9.52 ✻2 ø25.4 ✻2 ø12.7 P250VMH-E ✻1 ø22.2 ✻1 ø9.52 ✻2 ø12.7 ✻2 ø28.58 ✻1:R410A outdoor unit ✻2:R407C,R22 outdoor unit B Refrigerant piping brazing connection (gas A copper tube) : LP Refrigerant piping brazing connection (liquid B copper tube) : HP Drain hose 32mm(1-1/4inch) (accessory) 23 1250 Air outlet Air inlet 102 25 50x21=1050 1100 21-ø3 340 ····➀ ····➁ ····➂ 29 15 Drain hole (option) Control box Keep duct-work length 850mm or more. Terminal bed (Transmission) Drain hole 2 1 95 20 105 170mm±5mm (Actual Length) 3 Less than 550mm Terminal bed (Power source) 30 20 35 41 164 420 50x7= 350 44 327 50x6= 300 340 470 Less than 300mm 249 422 489 When installing the drain water lifting-up mech(option). 52 INDOOR UNIT Specifications & External Dimensions PCFY-P VGM-E Specifications PCFY-P40VGM-E PCFY-P63VGM-E Power source ❇ ❇ ❇ ❇ ❇ ❇ ❇ Cooling capacity Heating capacity 1 1 2 2 1 1 1 Cooling Heating Cooling Heating Power consumption Current 4.5 kW BTU/h kW kcal/h kW kcal/h BTU/h 15,400 4.7 4,000 5.0 4,300 17,100 0.10 0.10 0.46 0.46 kW kW A A External finish(Munsel No.) Dimension H x W x D mm in. Net weight Heat exchanger Type Fan Motor kg(lbs.) Airflow rate (Lo-Mid2-Mid1-Hi) ❇3 External staticpressure Type Output Air filter Gas(Flare) Refrigerant pipe diameter Liquid(Flare) Drain pipe diameter Noise level (Lo-Mid2-Mid1-Hi) ❇3 ❇4 m3/min L/s cfm PCFY-P100VGM-E PCFY-P125VGM-E ~ 220-240V 50Hz / ~220V 60Hz 11.2 7.1 24,200 38,200 7.3 11.6 10,000 6,300 12.5 8.0 6,900 10,800 27,300 42,700 0.16 0.13 0.16 0.13 0.73 0.60 0.73 0.60 0.70Y 8.59/0.97 210 x 1,310 x 680 270 x 1,310 x 680 210 x 1,000 x 680 14.0 47,800 14.5 12,500 16.0 13,800 54,600 0.24 0.24 1.10 1.10 270 x 1,620 x 680 8-5/16" x 39-3/8" x 26-13/16" 8-5/16" x 51-5/8" x 26-13/16" 10-11/16" x 51-5/8" x 26-13/16" 10-11/16" x 63-13/16" x 26-13/16" 27(60) 43(95) 37(82) 34(75) Cross fin (Aluminum plate fin and copper tube) Sirocco fan ✕ 2 Sirocco fan ✕ 3 Sirocco fan ✕ 4 8-10-11-12 133-167-183-200 253-353-388-424 12-14-16-18 200-233-267-300 424-494-565-636 0.054 mm(in.) mm(in.) ø 6.35(1/4") ø 12.7(1/2") dB(A) 26-28-32-35 433-467-533-583 918-989-1130-1236 0 Single phase induction motor 0.150 0.090 0.070 PP Honeycomb (long life) 5 5 3 ø 15.88( /8") / ø 19.05( /4") (Compatible) ø 15.88( /8") ø 9.52(3/8") I.D. ø26 (VP-25) 37-39-42-44 36-38-41-43 32-34-37-39 Pa kW 18-20-23-25 300-333-383-417 636-706-812-883 29-33-36-38 Note: ❇ 1 Cooling/Heating capacity indicates the maximum value at operation under the following condition. Cooling : Indoor 27˚C(80.6˚F)DB/19˚C(66.2˚F)WB,Outdoor 35˚C(95˚F)DB Heating : Indoor 20˚C(68˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB ❇ 2 Cooling capacity indicates the maximum value at operation under the following condition. Cooling : Indoor 27˚C(80.6˚F)DB/19.5˚C(67.1˚F)WB,Outdoor 35˚C(95˚F)DB (WR2: water 30˚C (80˚F)) Heating : Indoor 21˚C(69.8˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB (WR2: water 20˚C (68˚F)) ❇3 airflw rate/noise level are shown in (low-middle 2-middle 1-high). ❇4 It is measured in anechoic room. External Dimensions PCFY-P40,63,100,125VGM-E 140 320 80 150 18 Unit : mm 70 Model 40 63 Liquid ø6.35 ø9.52 100,125 ø9.52 Gas ø12.7 ø15.88 ø15.88(R410A) ø 19.05(R407C,R22) E (Suspension bolt pitch) 70 16 G F 81 96 Air outlet B A 182 I J High press. Low press. (Drainage) 254 506 680 56 229 87 H D Electrical box 161 Air intake PCFY PCFY PCFY PCFY 53 Model -P40VGM-E -P63VGM-E -P100VGM-E -P125VGM-E C A 1,000 1,310 1,310 1,620 B 904 1,214 1,214 1,524 C 918 1,228 1,228 1,535 D 983 1,290 1,290 1,600 90 E 933 1,240 1,240 1,547 F 210 210 270 270 G 180 180 207 207 H 157 157 217 217 I 201 201 198 198 J 241 241 245 245 INDOOR UNIT Specifications & External Dimensions PKFY-P VAM-E PKFY-P VGM-E Specifications PKFY-P20VAM-E PKFY-P25VAM-E PKFY-P32VGM-E PKFY-P40VGM-E PKFY-P50VGM-E ~ 220-240V 50Hz ~ 220V 60Hz 3.6 4.5 2.2 2.8 5.6 7,500 9,600 12,300 15,400 19,100 2.3 2.9 3.7 4.7 5.8 3,150 4,000 2,000 2,500 5,000 4.0 5.0 2.5 3.2 6.3 2,200 2,800 3,400 4,300 5,400 8,500 10,900 13,600 17,100 21,500 0.04 0.07 0.04 0.07 0.20 0.32 0.20 0.32 Plastic 2.60Y 8.66/0.69 Plastic white 0.70Y 8.59/0.97 340 x 990 x 235 (13-7/16" x 39" x 6-5/16") 295 x 815 x 158 (11-5/8" x 32-1/8" x 6-1/4") 16(36) 8.5(19) Cross fin (Aluminum plate fin and copper tube) Line flow fan ✕ 1 9-10-11-12 8-9.5-10.5-11.5 4.9-5.2-5.6-5.9 82-87-93-98 133-158-175-192 150-167-183-200 173-184-198-208 283-335-371-406 318-353-388-424 Power source ❇ ❇ ❇ ❇ ❇ ❇ ❇ Cooling capacity Heating capacity kW BTU/h kW kcal/h kW kcal/h BTU/h kW kW A A 1 1 2 2 1 1 1 Cooling Heating Cooling Current Heating External finish(Munsel No.) Dimension H x W x D Net weight Heat exchanger Type Power consumption ❇ 3 Airflow rate (Lo-Mid2-Mid1-Hi) Fan Motor mm(in.) kg(lbs.) m 3 /min L/s cfm Pa External static pressure Type Output 0 Single phase induction motor 0.030 0.017 kW Air filter Gas mm(in.) (Flare) Refrigerant pipe diameter PP Honeycomb (long life) ø 12.7(1/2") Liquid ø 6.35(1/4") mm(in.) (Flare) ø 12.7(1/2") / ø 15.88(5/8") (Compatible) ø 6.35(1/4") / ø 9.52(3/8") (Compatible) Drain pipe diameter I.D. ø16 (VP-16) 32-33-35-36 I.D. ø20 (VP-20) 33-36-38-41 dB(A) Noise level (Lo-Mid2-Mid1-Hi) ❇3 ❇4 Note: ❇ 1 Cooling/Heating capacity indicates the maximum value at operation under the following condition. Cooling : Indoor 27˚C(80.6˚F)DB/19˚C(66.2˚F)WB,Outdoor 35˚C(95˚F)DB Heating : Indoor 20˚C(68˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB ❇ 2 Cooling capacity indicates the maximum value at operation under the following condition. Cooling : Indoor 27˚C(80.6˚F)DB/19.5˚C(67.1˚F)WB,Outdoor 35˚C(95˚F)DB (WR2: water 30˚C(80˚F)) Heating : Indoor 21˚C(69.8˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB (WR2: water 20˚C(68˚F)) ❇ 3 Airflow rate/noise level are in (low-middle2-middle1-high). ❇ 4 It is measured in anechoic room. 34-37-40-43 External Dimensions Front view Left side 715 Air intake 340 Air intake 225 280 Air intake 80 Right side 13 295 Adress board 990 Lower side 660 (Total length of drain piping 760) 705 Air outlet 235 12-Louvers (manual) 160 40 60 80 110 50 450 Gas pipe 520 Liquid pipe 400 35 395 Service panel (Power supply access) Front view(to open the grille) Filter grip Terminal block for remote control 280 5 Terminal block for power supply Installation board 37.4 31 Intake direction 70 190 116 The address board is protected by a plastic cover. Remove the cover with a screwdriver (one screw) to set the board. 158 Knock out hole for under piping Refrigerant piping.Drain pipe. Wiring hole 79 60 Knock out hole for right piping Refrigerant pipe. Drain pipe. Wiring hole Address board 146 695 Outlet dimensions 60 235 Knock out hole for left piping Refrigerant pipe. Drain pipe.Wiring hole. MITSUBISHI PKFY-VAM 630 Intake dimensions 245 MITSUBISHI ELECTRIC Auto vane 60 Remote control terminal plate Power terminal plate 70 21 53 70 21 247.5 Intake dimensions 2.5 60 150 Less than 15 233 340 815 21.5 Unit : mm PKFY-P32,40,50VGM-E 245 13 783 198 Air intake 25.5 Intake dimensions PKFY-P20, 25VAM-E Liquid pipe ø6.35 Gas pipe ø12.7 481 (Left side piping installation) 35 549 17˚ Outlet angle 70.3 Address board Outlet Outlet dimensions Terminal plate direction Rotary switch (pair No.) Rotary switch (own address) Drain pipe (O.D. ø20) 54 86 700 (Flexible hose total length 800) 153 (Right side piping installation) Liquid pipe Gas pipe Model 32,40 50 Liquid pipe Gas pipe ø6.35 ø12.7 ø 6.35(R410A) ø 12.7(R410A) ø9.52(R407C,R22) ø15.88(R407C,R22) Dip switch (switches functions) 54 INDOOR UNIT Specifications & External Dimensions PKFY-P VFM-E Specifications PKFY-P63VFM-E Power source ❇1 ❇1 ❇2 ❇1 Heating capacity ❇1 Cooling Power consumption Heating Cooling Current Heating External finish(Munsel No.) Height Dimension Width Depth Net weight Heat exchanger Type Airflow rate ❇3 Fan (Lo-Hi) External static pressure kW BTU/h kcal/h kW BTU/h kW kW A A 7.1 24,200 6,300 8.0 27,300 0.12 0.12 0.55 0.55 mm(in.) mm(in.) mm(in.) kg(lbs.) 340(13-3/8) 1,400(55-1/8) 235(9-1/4) 24(53) Cooling capacity Motor 11.2 38,200 10,000 12.5 42,700 0.14 0.14 0.64 0.64 Plastic, white : <3.4Y7.7/0.8> 340(13-3/8) 1,680(66-1/8) 235(9-1/4) 28(62) Cross fin (Aluminum plate fin and copper tube) Line flow fan ✕ 2 m3/min 15-20 22-28 Pa Type Output 0 Single phase induction motor kW 0.040 0.070 Air filter PP Honeycomb (antibacterial) Gas Refrigerant pipe diameter PKFY-P100VFM-E 220-230-240V 50Hz / 220V 60Hz (Flare) Liquid (Flare) ø15.88(5/8) mm(in.) ø15.88(5/8) / ø19.05(3/4) mm(in.) ø9.52(3/8) Drain pipe diameter I.D. ø20 (VP-20) Noise level (Lo-Hi) dB(A) ❇3 ❇4 39-45 Note: 1. Cooling/heating capacity indicates the maximum value at operation under the following condition. ❇1 Cooling Indoor: 27˚C(80.6˚F)DB/19˚C(66.2˚F)WB, Outdoor: 35˚C(95˚F)DB Heating Indoor: 20˚C(68˚F)DB, Outdoor: 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB ❇2 Cooling Indoor: 27˚C(80.6˚F)DB/19.5˚C(67.1˚F)WB, Outdoor: 35˚C(95˚F)DB ❇3 Airflow rate/noise level are in (low-high). ❇4 It is measured in anechoic room. 41-46 External Dimensions PKFY-P100VFM-E 235 45 235 235 45 62.5 Unit : mm 235 45 235 45 235 45 235 45 235 Front Less than 15 2 197 Knock out hole for left piping C Less than 15 2 Bolt 42 58 Knock out hole for left piping A 235 340 197 C Right side 1680 1370 (Air intake) Left side 340 A Knock out hole for right piping 235 1400 1090 Air intake Left side 13 235 45 Top 13 62.5 PKFY-P63VFM-E 42 58 Bolt Drain hose Drain hose 55(Gas pipe) 107 120(Liquid pipe) 1 1110 (Drain hose) Lower side Auto vanes louvers(manual) 1120 552Air outlet 25 55 (Gas pipe) 120 (Liquid pipe) 102 111 1 Drain hose Drain hose for left-hand side piping 1110 (Drain hose) 183 Lower side 1400 240 240 694 Air outlet 552Air outlet 694 Air outlet louvers(manual) B Auto vanes Knock out hole for under-piping Refrigerant pipe .Drain pipe Knock out hole for under-piping Refrigerant pipe .Drain pipe Knock out hole for wiring Unit center 990 37 74 245 285 19 91 74 Unit center 1270 84-ø6 hole for tapping screw 18 Drainage range on right-hand side 285 19 900 91 180 12-ø6 hole for tapping screw 280 314 184 30 80 280 60 240 610 32-ø12 hole for bolt 30 225 55 90 Rear piping hole Range for left rear piping hole 245 595 13X91=(1183) 18 60 184 30 66-ø6 hole for tapping screw 32 Wall fixture 10 30 29 18 37 98 Unit out line 455 Wall fixture 39 Drainage range on left hand side Drainage range on right-hand side 10X91=(910) 900 18 C 30 37 65 100 39 37 74 32 Drainage range on left hand side B 10 30 29 98 100 4 39 39 4 37 74 A 30 39 100 C 30 37 65 100 4 39 B 4 Knock out hole for wiring A 30 B Under panel(Removable at left-hand side piping) Under panel(Removable at left-hand side piping) 80 280 Drain hose for left-hand side piping 111 183 41-ø12 hole for bolt 295 Range for left rear piping hole 225 240 180 12-ø6 hole for tapping screw 280 750 314 30 25 90 Rear piping hole Range for left rear piping hole INDOOR UNIT Specifications & External Dimensions New PFFY-P VKM-E Specifications PFFY-P20VKM-E PFFY-P25VKM-E Power source PFFY-P32VKM-E PFFY-P40VKM-E 1-phase 220-240V 50Hz Cooling capacity ❇1 kW 2.2 2.8 3.6 Heating capacity ❇1 kW 2.5 3.2 4.0 5.0 4.5 Power Cooling kW 0.025 0.025 0.025 0.028 consumption Heating kW 0.025 0.025 0.025 0.028 Current Cooling A 0.20 0.20 0.20 0.24 Heating A 0.20 0.20 0.20 0.24 Height mm 600 600 600 600 Width mm 700 700 700 700 Depth mm 200 200 200 200 kg 15 15 15 15 Dimension Weight Heat exchanger Cross fin (Alminium plate fin and copper tube) Line flow fan ✕ 2 Type ❇2 Airflow rate m3/min (Low-Mid-High-SHi) Fan 6.1-7.0-8.0-9.1 6.1-7.0-8.0-9.1 5.9-6.8-7.6-8.7 8.0-9.0-9.5-10.7 External static Pa pressure Motor 0 Type DC motor Output 0.03 ✕ 2 kW Air filter PP honeycomb fabric (Catechin Filter) Refrigerant Gas(Flare) mm pipe diameter Liquid(Flare) mm ❇2 ❇3 Noise level(Low-Mid-High-SHi) 12.7 6.35 dB(A) 35-38-42-44 28-32-35-38 28-32-35-38 27-31-34-37 Note: 1. Cooling/heating capacity indicates the maximum value at operation under the following condition. ❇1 Cooling Indoor: 27˚C(80.6˚F)DB/19˚C(66.2˚F)WB, Outdoor: 35˚C(95˚F)DB Heating Indoor: 20˚C(68˚F)DB, Outdoor: 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB ❇2 Airflow rate/noise level are in (Low-Mid-High-SHi). ❇3 It is measured in anechoic room. External Dimensions PFFY-P20,25,32,40VKM-E Unit : mm 131 131 7 4- 6 Hole 700 46.5 593 607 12 200 Air out 210 More than 100mm Indoor unit 12 46.5 333 363 Installation plate 337 More than 100mm More than 100mm Air in 96 600 337 118 Gas pipe 12.7(flared)1/2 Liquid pipe 6.35(flared)1/4 11 508 155 454 12 60 205 165 125 128 45 35 72 110 19 drain 137 60 123 54 147 12 60 60 19 125 60 Air out 60 80 56 INDOOR UNIT Specifications & External Dimensions PFFY-P VLEM-E PFFY-P VLRM-E Specifications PFFY-P20VLEM-E PFFY-P25VLEM-E PFFY-P32VLEM-E PFFY-P40VLEM-E PFFY-P50VLEM-E PFFY-P63VLEM-E Power source ❇1 ❇1 Cooling capacity ❇2 ❇2 ❇1 Heating capacity ❇1 ❇1 Cooling Power consumption Heating Cooling Current Heating External finish(Munsel No.) kW BTU/h kW kcal/h kW kcal/h BTU/h kW kW A A Dimension H x W x D mm in. kg(lbs.) Net weight Heat exchanger Type Fan ❇3 Airflow rate (Low-High) External static pressure Type Motor Output Air filter Gas Refrigerant pipe diameter (Flare) Liquid (Flare) Drain pipe diameter Noise level (Low-High) ❇3 ❇4 ❇5 m3/min L/s cfm ~ 220-240V 50Hz / ~ 208-230V 60Hz 3.6 4.5 5.6 7.1 12,300 15,400 19,100 24,200 3.7 4.7 5.8 7.3 3,150 4,000 5,000 6,300 4.0 5.0 6.3 8.0 4,300 5,400 6,900 3,400 17,100 21,500 27,300 13,600 0.065 / 0.075 0.06 / 0.07 0.085 / 0.09 0.1 / 0.11 0.065 / 0.075 0.06 / 0.07 0.085 / 0.09 0.1 / 0.11 0.32 / 0.33 0.29 / 0.30 0.40 / 0.41 0.46 / 0.47 0.32 / 0.33 0.29 / 0.30 0.40 / 0.41 0.46 / 0.47 Acrylic paint (5Y 8/1) 630 x 1,170 x 220 630 x 1,410 x 220 630 x 1,050 x 220 24-13/16" x 46-1/8" x 8-11/16" 24-13/16" x 55-9/16" x 8-11/16" 24-13/16" x 41-3/8" x 8-11/16" 23(51) 30(67) 25(56) 26(58) 32(71) Cross fin (Aluminum plate fin and copper tube) Sirocco fan✕ 2 Sirocco fan✕ 1 9.0-11.0 5.5-6.5 12.0-14.0 7.0-9.0 12.0-15.5 92-108 117-150 150-183 200-233 200-258 194-230 247-318 318-388 424-494 424-547 2.2 7,500 2.3 2,000 2.5 2,200 8,500 2.8 9,600 2.9 2,500 3.2 2,800 10,900 0.04 / 0.06 0.04 / 0.06 0.19 / 0.25 0.19 / 0.25 Pa 0 kW Single phase induction motor 0.030 0.018 PP Honeycomb fabric (washable) 0.015 mm(in.) mm(in.) dB(A) 34-40 0.035 0.063 ø 12.7 (1/2") ø 12.7 (1/2") [R410A] ø 15.88 (5/8") [R22,R407C] ø 15.88 (5/8") ø 6.35 (1/4") ø 6.35 (1/4") [R410A] ø 9.52 (3/8") [R22,R407C] ø 9.52 (3/8") Accessary hose ø 27 (top end : ø 20) 38-43 35-40 40-46 PFFY-P20VLRM-E PFFY-P25VLRM-E PFFY-P32VLRM-E PFFY-P40VLRM-E PFFY-P50VLRM-E PFFY-P63VLRM-E Power source ❇1 ❇1 ❇2 ❇2 kW BTU/h kW kcal/h ❇1 ❇1 ❇1 Cooling Power consumption Heating Cooling Current Heating External finish(Munsel No.) Dimension H x W x D kW kcal/h BTU/h kW kW A A Cooling capacity Heating capacity mm in. kg(lbs.) Net weight Heat exchanger Type Fan ❇3 Airflow rate (Low-High) External static pressure Type Motor Output Air filter Gas Refrigerant pipe diameter (Flare) Liquid m3/min L/s cfm ~ 220-240V 50Hz / ~ 208-230V 60Hz 3.6 4.5 5.6 7.1 12,300 15,400 19,100 24,200 3.7 4.7 5.8 7.3 3,150 4,000 5,000 6,300 4.0 5.0 6.3 8.0 4,300 5,400 6,900 3,400 13,600 17,100 21,500 27,300 0.065 / 0.075 0.06 / 0.07 0.085 / 0.09 0.1 / 0.11 0.065 / 0.075 0.06 / 0.07 0.085 / 0.09 0.1 / 0.11 0.32 / 0.33 0.29 / 0.30 0.40 / 0.41 0.46 / 0.47 0.32 / 0.33 0.29 / 0.30 0.40 / 0.41 0.46 / 0.47 Galvanizing 639 x 1,006 x 220 639 x 1,246 x 220 639 x 886 x 220 25-3/16" x 39-5/8" x 8-11/16" 25-3/16" x 49-1/16" x 8-11/16" 25-3/16" x 34-15/16" x 8-11/16" 27(60) 25(56) 20(45) 21(47) 18.5(41) Cross fin (Aluminum plate fin and copper tube) Sirocco fan✕ 2 Sirocco fan✕ 1 12.0-15.5 5.5-6.5 7.0-9.0 9.0-11.0 12.0-14.0 92-108 117-150 150-183 200-233 200-258 194-230 247-318 318-388 424-494 424-547 2.2 7,500 2.3 2,000 2.5 2,200 8,500 2.8 9,600 2.9 2,500 3.2 2,800 10,900 0.04 / 0.06 0.04 / 0.06 0.19 / 0.25 0.19 / 0.25 Pa kW mm(in.) 0 0.015 Single phase induction motor 0.030 0.035 0.018 PP Honeycomb fabric (washable) ø 12.7 (1/2") [R410A] ø 12.7 (1/2") ø 15.88 (5/8")[R22,R407C] (1/4") ø 6.35 [R410A] ø 9.52 (3/8") [R22,R407C] Drain pipe diameter Accessary hose ø 27 (top end : ø 20) dB(A) Noise level (Low-High) ❇3 ❇4 ❇5 38-43 35-40 34-40 Note: ❇ 1 Cooling/Heating capacity indicates the maximum value at operation under the following condition. Cooling : Indoor 27˚C(80.6˚F)DB/19˚C(66.2˚F)WB,Outdoor 35˚C(95˚F)DB Heating : Indoor 20˚C(68˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB ❇ 2 Cooling capacity indicates the maximum value at operation under the following condition. Cooling : Indoor 27˚C(80.6˚F)DB/19.5˚C(67.1˚F)WB,Outdoor 35˚C(95˚F)DB (WR2: water 30˚C(80˚F)) Heating : Indoor 21˚C(69.8˚F)DB,Outdoor 7˚C(44.6˚F)DB/6˚C(42.8˚F)WB (WR2: water 20˚C(68˚F)) ❇ 3 Air flow rate/noise level are in ( Low-High) ❇ 4 Measured point : 1m51m, Power supply : AC240V/50Hz ·1dB(A) lower at AC230V/50Hz ·2dB(A) lower at AC220V/50Hz ·3dB(A) lower at 1.5m✕1.5m point ❇ 5 It is measured in anechoic room. (Flare) 57 mm(in.) ø 6.35 (1/4") 0.063 ø 15.88 (5/8") ø 9.52 (3/8") 40-46 INDOOR UNIT Specifications & External Dimensions PFFY-P VLEM-E PFFY-P VLRM-E External Dimensions PFFY-P20,25,32,40,50,63VLEM-E Unit : mm Air supply grille (60) Note: 1. On Model :50, you would use flare nut packed with the Indoor Unit, when connnecting the Outdoor Unit for R407C, R22. 2. In order to increase the strength of the flare nut, the size of some of them has been 120 Remote controller can be built-in. (Program timer can not be built-in together) 40 G Air outlet C A 220 80 B 170 2 ✕ 2-12 ✕16 Wall mounting hole 15 160 Refrigeant piping flare connection(Liquid) F : HP 108 20 35 15 Refrigerant piping flare connection(Gas) E : LP 35 Strainer 78 300 630 500 310 50 Drain pan 100 ( 75 ) 170 430 Hose(accessory) OD ø 27(TOP ø 20) Level adjusting screw 4 pcs.(attached) Air inlet Air filter 6 10 45 90 D 170 B 220 2-12 ✕16 Floor mounting hole 21 25 10 220 B 640 640 760 760 C 600 600 720 720 D 610 610 730 730 E(Gas) F(Liquid) ø12.7 ø6.35 ø12.7 ø6.35 ø12.7 ø6.35 ø12.7 ø6.35 ✻1 ø12.7 ✻1 ø6.35 PFFY-P50VLEM-E 1410 1000 960 970 ✻2 ø15.88 ✻2 ø9.52 PFFY-P63VLEM-E 1410 1000 960 970 ø15.88 ø9.52 G(Liquid) G(Gas) 17 27 17 27 17 27 17 27 ✻1 22 ✻1 29 ✻2 22 ✻2 29 22 29 Piping space 106 A 1050 1050 1170 1170 183.5 Dimensions Model PFFY-P20VLEM-E PFFY-P25VLEM-E PFFY-P32VLEM-E PFFY-P40VLEM-E ✻1:R410A outdoor unit ✻2:R407C,R22 outdoor unit PFFY-P20,25,32,40,50,63VLRM-E 15 B 132 Note: 1. On Model :50, you would use flare nut packed with the Indoor Unit, when connnecting the Outdoor Unit for R407C, R22. 2. In order to increase the strength of the flare nut, the size of some of them has been increased. J 167 Air outlet A E 120 80 10 29 2- ø 4.7 Duct mounting hole C 2 ✕ F - ø 4.7 Duct mounting hole 30 8 49 2 ✕ 2 - 12 ✕ 16 Wall mounting hole Refrigerant piping flare connection(Gas) G : LP 90 220 98 84 Refrigeant piping flare connection(Liquid) H : HP 50 Drain pan 35 300 310 Strainer Hose(accessory) OD ø 27(TOP ø 20) ( 75 ) 170 430 400 639 100 15 9 Air inlet 76 Dimensions Model A B PFFY-P20VLRM-E 886 640 PFFY-P25VLRM-E 886 640 PFFY-P32VLRM-E 1006 760 PFFY-P40VLRM-E 1006 760 C 572 572 692 692 D 610 610 730 730 PFFY-P50VLRM-E 1246 1000 932 970 PFFY-P63VLRM-E 1246 1000 932 970 G(Gas) ø12.7 ø12.7 ø12.7 ø12.7 ø12.7 ✻1 720 7 ✻2 ø15.88 ø15.88 720 7 E 360 360 480 480 F 4 4 5 5 H(Liquid) ø6.35 ø6.35 ø6.35 ø6.35 ø6.35 ✻1 ✻2 ø9.52 ø9.52 Air filter 45 90 J(Liquid) J(Gas) 17 27 17 27 17 27 17 27 ✻1 22 ✻1 29 ✻2 22 ✻2 29 22 29 D B 15 2-12 ✕ 16 Floor mounting hole 106 Level adjusting screw 4 pcs.(attached) ✻1:R410A outdoor unit ✻2:R407C,R22 outdoor unit 58 INDOOR UNIT Specifications & External Dimensions PEFY-P VMH-E-F (Fresh Air Intake Type) Specifications PEFY-P80VMH-E-F Power source Cooling capacity Heating capacity kW BTU/h kW BTU/h kW kW A A Cooling Heating Cooling Heating Power consumption (50/60Hz) Current PEFY-P140VMH-E-F ~ 220-240V 50Hz / ~ 208-230V 60Hz ❇1 ❇1 ❇1 ❇1 9.0 30,700 8.5 29,000 0.16/0.21 0.16/0.21 0.67/0.91 0.67/0.91 16.0 54,600 15.1 51,500 0.29/0.33 0.29/0.33 1.24/1.48 1.24/1.48 External finish Height Width Depth Dimension Galvanizing 380(15") mm(in.) mm(in.) mm(in.) kg(lbs.) Net weight Heat exchanger Type 1000(39-3/8") Sirocco fan✕ 1 9.0 150 18 35/85/170 40/115/190 50/130/210 80/170/220 3 m /min L/s cfm Pa Pa Pa Pa 208V 220V 230V 240V External static pressure (Low/Mid/High) Type Motor Output Air filter (option) Refrigerant pipe diameter Drain pipe diameter 70(155") Cross fin (Aluminum plate fin and copper tube) Airflow rate Fan 1200(47-1/4") 900(35-7/16") 50(111") Gas(Flare) Liquid(Flare) kW 0.09 mm(in.) mm(in.) ø 15.88(5/8") Sirocco fan✕ 2 18.0 300 636 35/85/170 50/115/190 60/130/220 100/170/240 Single phase induction motor 0.14 Synthetic fiber unwoven cloth filter(long life) ø 15.88 (5/8") [R410A] / 19.05 (3/4") [R22,R407C] ø 9.52(3/8") 32 (1-1/4 inch) 28/38/43 34/43/45 27/38/43 208, 220V dB(A) 230, 240V 33/43/45 dB(A) Note: ❇ 1 Cooling/Heating capacity indicates the maximum value at operation under the following condition. Cooling : Indoor 33˚C(91.4˚F)DB/28˚C(82.4˚F)WB,Outdoor 33˚C(91.4˚F)DB Heating : Indoor 0˚C(32˚F)DB/-2.9˚C(26.8˚F)WB,Outdoor 0˚C(32˚F)DB/-2.9˚C(26.8˚F)WB ❇ 2 It is measured in anechoic room. a ). The cooling and heating capacities are the maximum capacities that were obtained by operating in the above air conditions and with a refrigerant pipe of about 7.5m(24-5/8Ft). b ). The actual capacity characteristics vary with the combination of indoor and outdoor units. See the technical information. c ). The operating noise is the data that was obtained by measuring it 1.5m(4-15/16Ft) from the bottom of the unit in an anechoic room. (Noise meter A-scale value) d ). The figure of Electrical characteristic indicates at 220V and at middle external static pressure. e ). When the 100% fresh air indoor units are connected, the maximum connectable indoor units to 1 outdoor unit are as follows. ❇2 Noise level Heat pump models 110%(100% in case of heating below-5˚C(23˚F) Cooling only 110% f ). Operational temp range is cooling : from 21˚C(61.8˚F)DB/15.5˚C (59.9˚F)WB to 43˚C(109.4˚F)DB/35˚C(95˚F)WB. Heating : from -10˚C(14˚F)DB to 20˚C(68˚F)DB ✻Thermo off (Fan) operation automatically starts either when temperature is lower than 21˚C(69.8˚F)DB in cooling mode or when the temperature exceeds 20˚C(68˚F)DB in heating mode. g ). As the room temp is sensed by the thermo in the remote controller or the one in the room, be sure to use ether remote controller or room thermo. h ). Dry mode is Not available. Fan mode operation during the thermo off in Cooling/Heating mode. i ). The fan would temporarily stops either with R2/WR2 system or in defrost. j ). In any case, the air flow rate should be kept lower than 110% of the above chart.Please see “ Fan curves “ for the details. k ). When this unit is used as sole A/C system, be careful about the dew in air outlet grilles in cooling mode. l ). Un-conditioned outdoor air such as humid air or cold air blows to the indoor during thermo off operation. Please be careful when positioning indoor unit air outlet grilles, ie take the necessary precautions for cold air, and also insulate rooms for dew condensation prevention as required. m). Air filter must be installed in the air intake side.The filter should be attached where easy maintenance is possible in case of usage of field supply filters. n). Long life filter cannot be used together with Hi-efficiency filter. External Dimensions PEFY-P80, 140VMH-E-F Unit : mm Required space for service and maintenance 625 G-ø3 100 ~20 0 700 00 ~2 150 450 50 E Access door Ceiling surface Make the access door at the appointed position properly for service maintenance. 50 Less than 300mm 170mm±5mm (Actual length) 80 50 41F 15 340 Model:80(Note3) 23 3 383 814 (Lifting bolt pitch) 904 Lifting bolt 250 60 900 847 24 10 Less than 550mm 70 10 15 Note 1.Use M10 screw for the lifting bolt (field supply). 2.Keep the service space for the maintenance from the bottom when the heat exchanger is cleaned. 3.This chart indicates for PEFY-P140VMH-E-F models, which have 2 fans. PEFY-P80VMH-E-F model has 1 fan. 4.Make sure to install the air filter(field supply) on the air intake side. In case field supplied air filter is used, attach it where the filter service is easily done. 5.On Model :140, you would use flare nut packed with the Indoor Unit, when connnecting the Outdoor Unit for R407C, R22. 6.In order to increase the strength of the flare nut, the size of some of them has been increased. Keep duct-work length 850mm or more. 30 Terminal bed (Transmission) Drain hole 250 380 77 P 94 50 50 50 50 Terminal box 130 41 25 50 340 50x5=250 45 Terminal bed (Power source) 328 2 17 3 When installing the drain water lifting-up mech(option). 29 Drain hole (option) Control box 59 Note2 More than 20mm Air outlet 50x(J-1)=K B (Lifting bolt pitch) A D C 50x(G-1)=H Access door Air inlet L 50 450 More than 20mm J-ø3 Refrigerant piping flare connection(gas M copper tube):LP Refrigerant piping flare connection(liquid N copper tube):HP Drain hose 32mm(1-1/4inch) (accessory) 1 92 200 343 387 D 850 F G E L J K H 800 25 17 800 15 700 1030 M ø15.88 ✻1 ø15.88 PEFY-P140VMH-E-F 1250 1204 1130 1050 1000 25 21 1000 19 900 1230 ✻2 ø19.05 Model PEFY-P80VMH-E-F C B A 1050 1004 930 N ø9.52 ø9.52 ······ ➀ ······ ➁ ······ ➂ P(Liquid) P(Gas) 29 22 22 36 ✻1:R410A outdoor unit ✻2:R407C,R22 outdoor unit INDOOR UNIT Specifications & External Dimensions PEFY-P VMH-E-F (Fresh Air Intake Type) Specifications PEFY-P200VMH-E-F PEFY-P250 VMH-E-F Power source 3N~ 380-415V 50Hz / 60Hz kW BTU/h kW BTU/h kW kW A A Cooling capacity Heating capacity Power consumption (50/60Hz) Current Cooling Heating Cooling Heating 22.4 76,400 21.2 72,300 0.34/0.42 0.34/0.42 0.58/0.74 0.58/0.74 28.0 95,500 26.5 90,400 0.39/0.50 0.39/0.50 0.68/0.86 0.68/0.86 External finish Height Width Depth Dimension Galvanized 470 (18-9/16") 1250 (49-1/4") 1120 (44-1/8") 100 (221") Cross fin Sirocco fan ✕ 2 mm(in.) mm(in.) mm(in.) kg(lbs.) Net weight Heat exchanger Type 3 28 467 989 140/200 150/210 160/220 m /min Airflow rate L/s cfm Pa Pa Pa Fan External static pressure Type Motor Output Air filter (option) Refrigerant pipe diameter 380V 400V 415V 3-phase induction motor 0.23 Synthetic fiber unmoven cloth filter (long life type) ø 19.05 (3/4") [R410A] ø 22.2 (7/8") [R410A] ø 25.4 (1") [R22,R407C] ø 28.58 (1-1/8") [R22,R407C] ø9.52 (3/8") [R410A] ø9.52 (3/8") [R410A] ø 12.7 (1/2") [R22,R407C] ø 12.7 (1/2") [R22,R407C] Unit drain pipe I.D 32 (1-1/4 inch) 39/42 40/44 40/43 40/45 40/44 41/46 kW Gas (Flare) mm(in.) Liquid (Flare) mm(in.) 380V 400V 415V dB(A) dB(A) dB(A) 0.20 Drain pipe diameter Noise level 35 583 1236 110/190 120/200 130/210 Note: 1. The cooling amd heating capacites are the maximum capacites that were obitained by operating in the above air conditions and with a refrigerant pipe of about 7.5m. 2 .The actual capacity characteristics vary with the combination of indoor and outdoor units. See the technical infomation. 3 .The operating noise is the data that was obitained by measuring it 1.5m from the the bottom of the unit in an anechoic room. (Noise meter A-scale value) 4 .The figure of Electrical characteristic , indicates at 220 Pa setting at 415V. 5 . When the 100% fresh air indoor units are connected, the maximum connectable indoor units to 1 outdoor unit are as follows. Heat pump models 110%(100% in case of heating below-5˚C(23˚F)) 6. Operational temp range is Cooling only 110% Cooling:from 21˚C(69.8˚F)DB/15.5˚C(59.9˚F)WB to 43˚C(109.4˚F)DB/35˚C(95˚F)WB Heating: from -10˚C(14˚F)DB to 20˚C(68˚F)DB. ❇ Thermo off(Fan) operation automatically starts either when temperature is lower than 21˚C(69.8˚F)DB in cooling mode or when the temperature exceeds 20˚C(68˚F)DB in heating mode. 7. As the room temp in sensed by the thermo in the remote controller or the one in the room, be sure to use either remote controller or room thermo. 8. Autochangeover function or Dry mode is NOT available. Fan mode operation during the thermo off in Cooling/Heating mode. 9. The fan would temporaly stops either with R2/WR2 system or in defrost. 10. In any case, the air flow rate should be kept lower than 110% of the above chart. Please see "Fan curves" for the details. 11. When this nit is used as sole A/C system, be careful about the dew in air outlet grilles in cooling mode. 12. Un-conditioned outdoor air such as humid air or cold air blows to the indoor during thermo off operation. Please be careful when positioning indoor unit air outlet grilles, ie take the necessary precautions for cold air, and also insulate rooms for dew condensation prevention as required. 13. Air filter must be installed in the air intake side. The filter should be attached where easy maintenance in possible in case of usage of fild supply filters. External Dimensions PEFY-P200, 250VMH-E-F Unit : mm Required space for service and maintenance 22-ø3 22-ø3 730 200~ 300 800 200 150~ 1350 More than 20 1100 23 3 Lifting bolt 4-14X30 Access door Ceiling surface Make the access door at the appointed position properly maintenance. 78 +5 170- When installing the drain water lifting-up 60 1034(Lifting bolt pitch) 340 Less than 300 1124 170mm+5mm (Actual length) 1120 1067 24 10 29 15 Drain hole (option) 30 20 Keep duct-work length 850mm or more. Terminal bed Drain hole (Power source) Terminal bed (Transmission) 2 95 Model 20 3 105 35 41 164 420 50x7=350 44 327 50x6=300 340 470 Control box Less than 550 420 Note2 More than 20 15 10 50 Access door 100 50 Air outlet 50 450 50x20=1000 1326(Lifting bolt pitch) 1372 Air outlet 102 25 1100 1250 50x21=1050 450 1 249 422 489 ······ Refrigerant piping brazing connection(gas A copper tube):LP Refrigerant piping brazing connection(liquid B copper tube):HP ······ Drain hose 32mm(1-1/4inch) (accessory) ······ A B PEFY-P200VMH-E-F ✻1 ø19.05 ✻1 ø9.52 ✻2 ø25.4 ✻2 ø12.7 ✻1 ø9.52 PEFY-P250VMH-E-F ✻1 ø22.2 ✻2 ø28.58 ✻2 ø12.7 ✻1:R410A outdoor unit ✻2:The other outdoor unit Note 1. Use M10 screw for the lifting bolt (field supply). 2.Keep the service space for maintenance from the bottom when the heat exchanger is cleaned. 3.Make sure to install the air filter (field supply) on the air intake side. In case field supplied air filter is used, attach it where the filter service is easily done. ➀ 4.On this model, you would use pipe ➁ packed with the Indoor Unit, when connnecting ➂ the Outdoor Unit for R407C, R22. 60 The Ventilation System for Enhanced Air Quality - Lossnay Combine with Lossnay Ventilation System Enhanced Air Quality. Unified Control System Allows Greater Design Freedom. Heat-Exchange Efficiency Obtainable Only with Lossnay. The secret to the unmatched comfort provided Lossnay core is the crossflow, plate-fin structure off the heat-exchange unit. A diaphragm made of a specially processed paper fully separates inducted and exhausted air supplies, ensuring that only fresh air is introduced to the indoor environment. The superior heat-transfer and moisture permeability of the special paper assure highly effective total heat exchange (temperature and humidity) when inducted ? and exhausted air supplies cross in the Lossnay core. 5.2 0 Stale hot air (exhaust) Fresh cool air(outdoor) Stale air exhaust (dirty indoor air) Lossnay Element Construction & Principle Fresh air exhaust (fresh heating / cooling air) EA SA 20 Stale warm air (indoor air) Outdoors 14.8 Indoors OA Fresh warm air (indoor supply air) Fresh air induction (fresh air) LGH-15RX4 LGH-25RX4 LGH-35RX4 LGH-50RX4 LGH-65RX4 LGH-80RX4 LGH-100RX4 LGH-150RX4 LGH-200RX4 RA Stale air induction (dirty heating / cooling air) [150m3/h Single phase 220-240V 50/60Hz] [250m3/h Single phase 220-240V 50/60Hz] [350m3/h Single phase 220-240V 50/60Hz] [500m3/h Single phase 220-240V 50/60Hz] [650m3/h Single phase 220-240V 50/60Hz] [800m3/h Single phase 220-240V 50/60Hz] [1000m3/h Single phase 220-240V 50/60Hz] [1500m3/h Single phase 220-240V 50/60Hz] [2000m3/h Single phase 220-240V 50/60Hz] OA Processing Units Ideal Indoor-Air Quality — For Your Comfort and Health The OA (outdoor-air) Processing Unit creates an optimum indoor-air environment at an unparalleled rate of cost efficiency providing substantial energy savings. Forced air ventilating and humidifying functions unique to this system keep indoor-air fresh and free of contaminants preventing “sick building syndrome” and the spread of airborne viruses such as the flu. Another novel feature of the OA Processing Unit is the “Lossnay core,” a heat-exchange unit that functions to transfer heat efficiently, cutting ventilation load by as much as 70%. This special combination of functionality and performance designed to ensure users ample comfort and year-round health cannot be found anywhere else on the market. EA (Exhaust air) Heat from the indoor air (both sensible and latent) is recovered by the Lossnay OA (Outdoor air) Core and vented outside by the Fresh, outdoor-air in a quantity exhaust fan. required for ventilation is drawn in by the supply fan. Heat recovery unit (Lossnay Core) Temperature and humidity are exchanged between the supply air and the exhaust air. OA Processing Units The exhaust fan High efficiency filters (Option) The supply fan RA (Return air) The exhaust fan draws in contaminated indoor-air. Maintenance cover Air filter Prevents clogs in the Lossnay Core. DX Heat exchanger Cools or heats the drawn in outdoor-air. SA (Supply air) The processed, fresh outdoor-air is vented to the indoor rooms. GUF-50RD(H)3 *1 Cooling Capacity 5.29 (DX coil:3.63, Lossnay:1.66)KW Heating capacity 6.42 (DX coil:4.17, Lossnay:2.25)KW 500m3/h Single phase 220-240V 50Hz GUF-100RD(H)3 *1 Cooling Capacity 10.81 (DX coil:7.32, Lossnay3.49)KW Heating capacity 13.00 (DX coil:8.30, Lossnay:4.70)KW 1000m3/h Single phase 220-240V 50Hz *1 H : Humidifying Type 61 INDOOR UNIT Y : PUHY R2 : PURY WY : PQHY WR2 : PQRY S : PUMY PLFY-VAM / VCM PCFY-VGM PLFY-VLMD PKFY-VAM / VGM / VFM PMFY-VBM PFFY-VKM PEFY-VMS PFFY-VLRM / VLEM PEFY-VMR Fresh Air Intake type PEFY-VML / VMM / VMH LONWORKS 62 Integrated Communications Control with Mitsubishi's Unique Transmission Network(M-NET) Model No. of units controllable (Groups (G) / units) Local remote controller Simple Wireless Remote controller remote remote controller controller PAR-FL32MA PAR-21MAA PAR-F27MEA PAC-SE/YT51CRA PAR-FA32MA System controller ON/OFF Group System Schedule Centralized controller remote remote remote timer controller controller controller PAC-YT40ANRA PAC-SC30GRA PAC-SF44SRA PAC-YT34STA G-50A GB-50A TG-2000A 50G/50units 50G/50units 1G/16units 1G/16units 1G/16units 1G/16units 16/50 8G/16units 50/50 50G/50U 2000G/2000units G-50A browser GB-50A browser Operation Start / Stop ✕ Operation mode Temperature setting Permit / Prohibit direction ✕ ✕ ✕ ✕ Fan speed ✕ Air flow direction ✕ *4 ✕ ✕ *4 ✕ ✕ *4 ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ON/OFF Error flashing ✕ Error content Monitoring ✕ ✕ ✕ ✕ ✕ ✕ ✕ Operation mode ✕ ✕ ✕ ✕ Set temperature ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ Filter sign Operating hour ✕ ✕ ✕ Indoor temperature (intake) ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ Permit / Prohibit Fan speed ✕ Air flow direction *5 Weekly Scheduling Annual (Designated day setting) ✕ ✕ ✕ *5 8 Times of stops / Starts per week 56 *5 *5 ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕/ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ *5 ✕ 16 3/3 12 ✕ 12 12 *5 112 21/21 84 ✕ 84 84 ✕ Times of stops / Starts per day 1/1 ✕ 5 10 * ✕ ✕ 1/1 ✕ ✕ ✕ ✕ ✕ /336 ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ 5 10 1 ✕ 1 1 ✕ /48 *5 ✕ 10 ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ Minimum setting unit (minutes) 1 Error history ✕ Daily / Monthly reports Electricity charges ✕ /30 ✕ Set temperature range limit ✕ ✕ ✕ ✕ Auto lock ✕ ✕ ✕ ✕ ✕/ ✕/ *1 Group setting ✕ ✕ ✕ /✕ ✕ ✕ ✕ ✕ ✕ ✕/ *2 ✕ / ✕ ✕ ✕ ✕ ✕ *2 *2 ✕ ✕ ✕ / ✕ *2 ✕ ✕ *2 *2 ✕ *2 ✕ ✕ ✕ ✕ ✕ Revision of electricity charges ✕ ✕ ✕ ✕ ✕ / Start / Stop *3 / ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ –/ / / / / / / / Fan speed ✕ ✕ –/ / ✕ / / ✕ / / Ventilation mode ✕ ✕ –/✕ /✕ ✕ /✕ /✕ ✕ /✕ /✕ Status ✕ ✕ –/ / ✕ / / / / Fan speed ✕ ✕ –/ / ✕ / / ✕ / / Ventilation mode ✕ ✕ –/✕ /✕ ✕ /✕ /✕ ✕ /✕ /✕ : Each group / Batched : Each group : Block (City Multi indoor unit only) ✕ : Not available : Batched handling (for maintenance) : Batched only – : Not used 63 ✕ *2 Block setting Ventilation Ventilation (group / interlocked) (group / interlocked) Control and Others Recording management ✕ ✕ Auto off timer Monitoring Operation ✕ ✕ One day Ventilation (group / interlocked) ✕ / : G-50A license registration possible. *1: For group operation, cross-over wring is required between indoor unit. *2: Installation possible at Initial setting tool. *3: Interlock setting from local remote controller. *4: From schedule setting *5: When PAC-YT32PTA is connected. Building Air conditioning control system HAND-HELD REMOTE CONTROLLER MA REMOTE CONTROLLER PAR-21MAA High-quality pure-white color body Dot liquid-crystal display is applied Symbols, Japanese, Chinese, English, Germany,Spanish, Russian, Italian, French display can be selected freely. Connectable to all CITYMULTI indoor unit, and automatically adjust its function with the indoor unit connected Limiting temperature setting range is possible Help to avoid over-cooling or over-heating. Save energy. Auto-stop timer is available Help to avoid forgetting to stop the air conditioner. Weekly scheduler is available ON/OFF/Temperature setting 8 times per day, 1 week scheduling. Grouping via cross-over wire directly Usable as the local remote controller for system controller (MELANS) Combining ME remote controller and/or LOSSNAY remote controller in a group is not possible. LCD temperature setting and display in 1˚C /1˚F unit. TM Example of system configuration M-NET Non-polarized 2-wire Non-polarized 2-wire MA remote controller MA remote controller ME REMOTE CONTROLLER PAR-F27MEA Example of system configuration ME remote controller ME remote controller Easy to read, easy to operate icon display Temperature selection Room air temperature display Outlet angle display Displays the angle of blowing between 20˚ and 70˚. (Only for cassette model PL and PK. Ceiling mounted models display the air volume ratio.) Auto-diagnosis display A microcomputer constantly monitors operation to keep the units running smoothly. Should problems occur, the temperature setting display changes to an auto-diagnosis display that shows the inspection mode and the unit address alternately. Standardized remote controllers for all indoor units All wiring is simply done with non-polarized two-wire signal lines Room thermometer is built into the remote controller Daily timer Repeated ON / OFF timer every day. Auto OFF timer 0:30, 1:00, 1:30, 2:00...4:00 one touch timer. Function lock All functions or all functions except ON / OFF can be selected. Limit setting of room temperature. 64 Building Air conditioning control system HAND-HELD REMOTE CONTROLLER SIMPLE MA REMOTE CONTROLLER PAC-YT51CRA To simplify operation of the system, the range of controls has been limited to START/STOP, room temperature and fan speed The only wiring required is cross-over wiring based on two-wire signal lines Room temperature sensors are built-in. The indoor unit can be replaced with body thermostats Easy to read, easy to operate icon display LCD temperature setting and display in 1˚C /1˚F unit. Can operate all types of indoor units Standardized remote controllers for all indoor units *Since this system has no operation mode switching, test operation, selfdiagnosis or interlock setting functions, it should always be used in conjunction with the PAR-21MAA or other centralized controller. *Combining ME remote controller and/or LOSSNAY remote controller in a group is not possible. PAC-YT51CRA WIRELESS REMOTE CONTROLLER PAR-FL32MA / PAR-FA32MA • Wireless construction supports multi - systems in buildings. • No need to configure addresses for group operation. • Lit LED keeps you informed of operation - blinking even gives you the error code via the number of blinks. • Can be used with the MA remote controller. *When used in group configurations, wiring between indoor units is required. *Combining ME remote controller and/or LOSSNAY remote controller in a group is not possible. • LCD temperature setting and display in 1˚C /1˚F unit. PAR-FL32MA 65 PAR-FA32MA Building Air conditioning control system CENTRALIZED REMOTE CONTROLLER CENTRAL CONTROLLER G-50A/GB-50A Up to 50 units of packaged air conditioners can freely be monitored and operated! Furthermore, it has enabled the Monitoring and Operation Via a Web Browser on a Personal Computer connected to it using a LAN or telephone line! First in the industry With Web Server Functions! G-50A (with display) GB-50A Simple and Flexible This new generation controller is suitable for small to large systems with simple to complex functions available. Web Browser Enables monitoring and operation of air conditioning units using a PC with Microsoft® Internet Explorer. Remote Access Allows users to remotely monitor and operate the air conditioning units using a PC connected to a telephone line. Auto Alarm In the case of any malfunction, necessary information will be sent to a mobile phone and/or personal computer by e-mail. Easy to Upgrade Various new functions will be introduced gradually and can easily be down loaded into any existing G-50A/GB-50A. Example: Energy Monitoring Demand Control Annual Schedule Example of display icons (air conditioner icons) Operation In timer operation Stop Lossnay on Occurrence of abnormality Under energy-saving control Operation/ Occurrence of a filter sign System Structure Remote monitoring via a Web browser Web browser City Multi outdoor unit G-50A M-NET Public telephone line Router Ethernet UP Provider POWER SUPPLY UNIT MODEL PAC-SC50KUA POWER RATING 2.11kg WEIGHT SERIAL No. MITSUBISHI ELECTRIC CORPORATION Power supply unit PAC-SC50KUA City Multi City Multi outdoor unit GB-50A M-NET Provider UP POWER SUPPLY UNIT MODEL PAC-SC50KUA POWER RATING WEIGHT SERIAL No. 2.11kg MITSUBISHI ELECTRIC CORPORATION Power supply unit PAC-SC50KUA City Multi * Microsoft is a trademark or trademark of Microsoft corporation. 66 Building Air conditioning control system CENTRALIZED REMOTE CONTROLLER GROUP REMOTE CONTROLLER PAC-SC30GRA Up to 8 groups can be operated (maximum of 16 units). Just by pressing switches, groups can be started and stopped individually, or all groups can be started and stopped as a batch. Detailed settings and operations can also be made for each individual group. All the wiring is simply done with non-polarized two wire signal lines. The connection is the same as the connection to the master system controller. It supports operation of groups that can extend beyond one refrigerant system. Furthermore, it is possible to drive interlocked systems that use ventilator equipment or drive ventilator equipment in a stand-alone situation. *With the group remote controller, you cannot control groups that only contain the LOSSNAY remote controller. *It is impossible to use the group remote controller to control K control units. *When connecting to signal cables for central control, it must use a power supply unit for the signal cables. System example Connect to the centralized transmission line Group remote controller UP Power supply unit MA R/C MA R/C MA R/C MA R/C R/C:Remote Controller Connect to the indoor/outdoor transmission line 67 R/C:Remote Controller Group remote controller Building Air conditioning control system CENTRALIZED REMOTE CONTROLLER SYSTEM REMOTE CONTROLLER PAC-SF44SRA 50 groups/50 units of air conditioners can be controlled Up to 50 groups/50 units of air conditioners can be operated with one remote controller. A general-purpose interface is available for control, so general devices can also be turned ON and OFF. Operation status displayed on easy-to-read LCD The group currently operating can be seen at a glance with the operation status display for each group. Independent LOSSNAY operation is possible LOSSNAY units can be grouped the same as the Central remote controller and ON/OFF remote controller. "Automatic ventilation", "Normal ventilation" and "Ventilation with heat exchanger" can be switched from the system controller. Simple remote controller limited to basic operations. The only operations required for the air conditioner are "ON/OFF", "Operation mode changeover", "Temperature setting" and "Prohibit operation by local remote controller", so anyone can easilyoperate the unit. Using collective control from the system remotecontroller, operation mode settings using the local remote controllers can be prohibited. (Operation mode limit function) Schedule operation is available Groups of air conditioners are available for operation at a set schedule using the Schedule timer (PAC-YT34STA). System example System remote controller UP Power supply unit MA R/C LOSSNAY PZ-52SF MA R/C LOSSNAY LOSSNAY PZ-52SF R/C:Remote Controller 68 Building Air conditioning control system CENTRALIZED REMOTE CONTROLLER Schedule timer PAC-YT34STA The weekly schedule of up to 50 groups/50 units can be controlled with one schedule timer. General-purpose devices can also be turned ON and OFF by connecting a general-purpose interface. The weekly schedule of up to ten patterns (no setting + nine patterns) is available for setting. "ON/OFF", "Operation Prohibit", "COOL/HEAT" and "Set Temperature" can be scheduled with up to 16 settings in one pattern. It can be connected to the center control transmission line or to the indoor/outdoor transmission line without the power supply unit (PAC-SC50KUA). It is nonpolar 2-wire. It can be interlocked with a building management system using the external input/output managing function. An error unit address and error code appear on the display. (*) Use in combination with other system controllers. System example System remote controller UP Power supply unit LOSSNAY ME R/C Schedule timer MA R/C R/C:Remote Controller 69 Simple ME R/C Building Air conditioning control system CENTRALIZED REMOTE CONTROLLER ON/OFF remote controller PAC-YT40ANRA 16 groups/50 units can be controlled Up to 16 groups/50 units can be operated with one ON/OFF remote controller. A general-purpose interface is available for control, so general devices can also be turned ON and OFF. Just press a switch to start. All of the units can be started and stopped by pressing the main switch, and each unit in the group can be started and stopped with individual switches. A general-purpose interface is available for control, so general devices can also be turned ON and OFF. LED flashing during failure. If any error should occur in the air conditioner, its details can be confirmed easily with the flashing LED. The LED also indicates whether each group is running or stopped. Interlock operation with external system possible. It can be flexibly interlocked with a card reader, fire alarm system or building management system, etc., using the incorporated external input/output function. Flexible group setting. The groups can be easily configured, so the group pattern can be freely set according to the layout. The ON/OFF remote controller can be connected at the indoor/outdoor transmission line without the power supply unit. System example LOSSNAY PAR-F27MEA PZ-52SF ON/OFF remote controller PAR-21MAA PAC-YT51CRA R/C:Remote Controller 70 Building Air conditioning control system CENTRALIZED REMOTE CONTROLLER Integrated centralized control software TG-2000A (1) Example of Basic System Configuration. Single-phase 208/230V M-NET Charge license Input G-50A 12VDC Single-phase 208/230V Web monitor license UP POWER SUPPLY UNIT MODEL PAC-SC50KUA POWER RATING WEIGHT SERIAL No. 2.11kg MITSUBISHI ELECTRIC CORPORATION Power supply unit PAC-SC50KUA Schedule license 3-phase 208/230V (3-wire) Indoor unit system watt-hour meter Compatible with TG-2000A Ver. 4.10 and higher * The electric amount count software or separately procured parts must be used with the designated PLC. Indoor unit watt-hour meter power source Outdoor unit system watt-hour meter Indoor unit system watt-hour meter Indoor unit watt-hour meter RS-485 Outdoor unit system watt-hour meter RS-232C Converter PLC (with electric amount count software) Central controller personal computer TG-2000A Uninterruptive power supply (UPS) Uninterruptible power supply (UPS) Integrated centralized control software installation Central control personal computer TG-2000A Integrated centralized control software installation The TG-2000A can realize the following functions using the G-50A/GB-50A option (license). * Operation/monitor * Annual/weekly schedule * Charge * Energy saving *1 * Peak cut *1 *1: Compatible with TG-2000A Ver. 4.10 and higher, G-50A Ver. 2.51 or later. Main features of TG-2000A 1 Up to 2000 indoor units (40 G-50A/GB-50A units) can be operated and monitored simultaneously. 2 The air-conditioner layout can be displayed on the screen, making control and operation easier. 3 The annual and weekly schedules can be set. Two schedules, such as the summer master and winter master, can be saved in the weekly schedule. 4 Air-conditioning charges can be calculated based on the multiple air-conditioner usage results. The power apportionment 5 6 7 8 71 percentage data and apportioned power rate can be calculated for each indoor unit using the power apportionment function, and can be output as a CSV format file. * Power apportionment charging is not possible with the old model, A control or K control. Charging without WHM : The user manually inputs the power rate to calculate the air-conditioning charges. (Using a tool) RS-485 WHM charging : The RS-485 WHM value is automatically tabulated to calculate the air-conditioning charges. PLC + pulse WHM charging : The pulse output WHM value is automatically tabulated by the PLC to calculate the air-conditioning charges. Energy saving operation is possible using the "ON/OFF", "set temperature change", "fan operation changeover" and "performance save operation (60% to 90%)" functions. Energy saving operation matching the amount of power in use is possible by using the PLC's electric amount count software. Night set-back operation is possible with schedule settings. *1*4 General equipment can be operated and monitored. *2 General equipment can be schedule-controlled when using PAC-YG21CDA with PLC. For details of PLC refer to Installation Manual of PAC-YG21CDA. *3 *1: Compatible with TG-2000A Ver. 4.10 and higher, G-50A Ver. 2.51 and higher. *2: Compatible with TG-2000A Ver. 4.30 and higher, G-50A Ver. 2.51 and higher. *3: Compatible with TG-2000A Ver. 4.60 and higher, G-50A Ver. 2.70 and higher. *4: With Night Set-Back function,the CITY MULTI system can run at heating mode with target temperature set to 54 F/12 C under schedule control. This function can protect the room from dropping down to extremely low temperature at mid-night. Building Air conditioning control system CENTRALIZED REMOTE CONTROLLER LONWORKS (LMAP02) CITY MULTITM can easily combine into a Building Management System (BMS) via the LonWorksTM and M-NET adapter LMAP03-U. LonWorksTM is an opened transmission protocol widely used at BMS, and related equipment control. CITY MULTITM is therefore compatible with large-scaled BMS management via LonWorksTM. One LM ADAPTER unit can connect up to 50 Groups/50 indoor units. Using a single LONWORKS adapter (LM ADAPTER), you can connect up to a maximum of 50 indoor units. Operation Monitor LMAP LMAP 02 Protocol converter between LON WORKS and M-NET L ON WORKS Item Request On/Off Request Mode Setpoint from network (Both cool and heat) Request Fanspeed Request Local Prohibit On/Off Request Local Prohibit mode Request Local Prohibit SetPoint Request All Off On/Off run state Mode state Setpoint state (both cool and heat) FanSpeed state Thermo On/Off state Temperature state of indoor Alarm state Local Prohibit On/Off state Local Prohibit mode state Local Prohibit SetPoint state M-NET LMAP CITY MULTI System Example of System Configuration CITY MULTI System design made simple through integration of various devices into a total control configuration. Outdoor unit Outdoor unit 208-230V 60Hz LON WORKS (78kdps) M-NET LMAP Indoor units Max. 50 indoor units Indoor units Indoor units Indoor units Indoor units Lighting Center control device Security Remote controller Remote controller Remote controller Remote controller Remote controller LON WORKS The building management system is connected to the CITY MULTI air conditioning system using LON WORKS , which is widely used on field networks, allowing for an open network and savings in construction to face. LON, LON WORKS and the Echelon logo are trademarks of Echelon Corporation registered in the United States and other countries. 72 Building Air conditioning control system CENTRALIZED REMOTE CONTROLLER BACnet TM interface(PAC-YG31CDA) MITSUBISHI ELECTRIC's CITYMULTI can be easily connect to the building management system through BACnet. BACnet is the appropriate transmission method and used in many of the backbone networks and also it is easy to combine with other equipment corresponding to BACnet. One BACnet interface software manages up to 500 Groups/500 Indoor units. (10 G-50A/GB-50A units). (1) Example of Basic System Configuration. Central monitor BACnet BMS TM M-NET LAN G-50A BACnetTM interface software PAC-YG31CDA UP M-NET PAC-SC50KUA Power supply unit G-50A Web Browser (Optional) TG-2000A (Optional) Operation Monitor 73 Item On/Off (state) Operation mode (state) Fan Speed (state) Air direction (state) Room Temp. Filter Signal Alam signal Error Code Communication State On/Off (setup) Operation mode (setup) Fan Speed (setup) Air direction (setup) Set Temp. Filter Signal Prohibition of local operation (On/Off) Prohibition of local operation (Mode) Prohibition of local operation (filter reset) Prohibition of local operation (Set temp.) System Forced Off WHM WHM CITY MULTI OPTIONAL PARTS R410A OPTIONAL PARTS FOR OUTDOOR UNITS For PU(H)Y, PURY series Description Model Remarks High static pressure motor PAC-KBU04MT-F ~ 60Pa Note: In case of using PAC-KBU04MT-F, when carrying out intensive install of the outdoor unit, please extend on installation interval to 20mm or more. For PU(H)Y, PURY series Description Branch pipe (Joint) Model CMY-Y102S-G 200 or below CMY-Y102L-G1 201-400 CMY-Y202-G1 CMY-Y302-G1 Branch pipe (Header) Total capacity of indoor unit 401-650 The 1st branch of P450~P650 651 or above The 1st branch of P700~P1250 CMY-Y104-G For 4 branches CMY-Y108-G For 8 branches CMY-Y1010-G For 10 branches Note : Indoor unit capacities The capacity of an indoor unit is the same as the number used for its type identification. For PUMY-P100, P125, P140YHM / PUMY-P100, P125, P140VHM Description Model Branch Pipe (2 Branch) CMY-Y62-G-E Header CMY-Y64-G-E Header CMY-Y68-G-E Drain Socket PAC-SG61DS-E Centralized Drain Pan PAC-SG64DP-E Port Connector (ø9.52 → ø12.7 ) PAC-SG73RJ-E Port Connector (ø15.88 → ø19.05) PAC-SG75RJ-E Air Protect Guide ( 2 pcs required ) PAC-SH63AG-E OPTIONAL EQUIPMENT FOR BC CONTROLLER BC Controller Model CMB-P104V-G, GB CMB-P105V-G CMB-P106V-G CMB-P108V-G, GA, GB CMB-P1010V-G, GA CMB-P1013V-G, GA CMB-P1016V-G, GA Junction pipe kit CMY-R160-J Branch pipe CMY-Y102S-G 74 CITY MULTI OPTIONAL PARTS R410A OPTIONAL PARTS FOR INDOOR UNITS 4-way cassette type (PLFY-VCM / VAM) Description Decoration panel Multi-function casement High-efficiency filter element Air outlet shutter plate (1 set) Model SLP-2AA PLP-6AA PAC-SG03TM-E PAC-SG01KF PAC-SG06SP-E 2-way cassette type (PLFY-VLMD) Description Model CMP-40VLW-B CMP-63VLW-B CMP-100VLW-B CMP-125VLW-B PAC-KH11OF Decoration panel OA duct flange Applicable capacity PLFY-VLMD-B P20, P25, P32, P40 P50, P63 P80, P100 P125 P20, P25, P32, P40, P50, P63, P80, P100 Applicable capacity VAM – P32, P40, P50, P63, P80, P100, P125 P32, P40, P50, P63, P80, P100, P125 P80, P100, P125 P32, P40, P50, P63, P80, P100, P125 VCM P20, P25, P32, P40 – – – – 1-way cassette type(PMFY-VBM) Description Model Applicable capacity Decoration panel PMP-40BM P20, P25, P32, P40 Ceiling concealed type (PEFY-VMH) Description Drain lift-up mechanism Long life filter Filter box Model PAC-KE04DM-F PAC-KE32LAF-F PAC-KE86LAF PAC-KE88LAF PAC-KE89LAF PAC-KE85LAF PAC-KE63TB-F PAC-KE80TB-F PAC-KE140TB-F PAC-KE250TB-F Applicable capacity PEFY-VMH P40~P250 – P40, P50, P63 P71, P80 P100, P125, P140 P200, P250 P40, P50, P63 P71, P80 P100, P125, P140 P200, P250 Remarks Standard Filter is attached Necessary when long life filter is used Ceiling concealed type (PEFY-VMM) Description Round shape duct flange Drain lift-up mechanism Model Applicable capacity PAC-KE32EDF-F PAC-KE50EDF-F PAC-KE80EDF-F PAC-KE125EDF-F PAC-KE140EDF-F PAC-KE03DM-F P20, P25, P32 P40, V50 P63, P71, P80 P100, P125 P140 P20, P25, P32, P40, P50, P63, P71, P80, P100, P125, P140 Ceiling suspended type (PCFY-VGM) Description High efficiency filter Drain lift-up mechanism Model PAC-SE80KF-E PAC-SE81KF-E PAC-SE82KF-E PAC-SE84DM-E PAC-SE85DM-E PAC-SE86DM-E Applicable capacity P40 P63, P100 P125 P40 P63 P100, P125 Fresh air intake type (PEFY-VMH-E-F) Description Long life filter Filter box Drain water lift-up kit 75 Model PAC-KE88LAF PAC-KE89LAF PAC-KE85LAF PAC-KE80TB-F PAC-KE140TB-F PAC-KE250TB-F PAC-KE04DM-F Applicable capacity P80 P140 P200, P250 P80 P140 P200/P250 P80, P140, P200, P250 Single phase Multi Split system (5HP) MSZ-FA series MSZ-FA series MSZ-GA series Branch Box SLZ series MFZ series PEAD series PLA series SEZ series MXZ-8A140VA Single phase, 50Hz Up to 8 indoor units can be connected ! *MXZ-8A140VA can NOT be connected with City Multi indoor units. The Air Conditioning & Refrigeration Systems Works acquired ISO 9001 certification under Series 9000 of the International Standard Organization (ISO) based on a review of Quality , management for the production of refrigeration and air conditioning equipment. FM 33568 / ISO 9001;2000 ISO Authorization System The ISO 9000 series is a plant authorization system relating to quality management as stipulated by the ISO. ISO 9001 certifies quality management based on the "design, development, production, installation and auxiliary services" for products built at an authorized plant. The Air Conditioning & Refrigeration Systems Works acquired environmental management system standard ISO 14001 certification. The ISO 14000 series is a set of standards applying to environmental protection set by the International Standard Organization (ISO). Certificate Number EC97J1227 http://Global.MitsubishiElectric.com/ MITSUBISHI ELECTRIC PRODUCTS ARE DISTRIBUTED BY... HEAD OFFICE: MITSUBISHI DENKI BLDG., 2-2-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN http://Global.MitsubishiElectric.com MEE05K437 New publication effective Jul. 2006 Specifications subject to change without notice