Sealed lead-acid battery UPS Series Model: UPS 12 - 80 UPS type batteries are made in AGM technology and are constructed by plates, separators, safety valves and a container. Since the electrolyte is held by a glass-mat separator and plates, the batteries can be used in any chosen position without the risk of leakage. UPS type batteries have a pressure relief valves that allows safe dispersal of any excess pressure inside the cell (VRLA). UPS type batteries have been designed for standby use in uninterruptible power supplies (UPS). These batteries are the replacement for DYNASTY batteries (C&D Technologies former Johnson Controls). They have the same dimensions but a larger capacity and better constant power and constant current discharge characteristics. TECHNICAL DATA APPLICATIONS Ÿ Ÿ Ÿ Ÿ Ÿ uninterruptible power supplies (UPS) emergency lighting systems telecommunication PABX power station fire and security systems cable TV solar powered systems mobile and portable equipment – cycle use marine wheelchairs golf-carts Ÿ Ÿ Ÿ Ÿ Ÿ DIMENSIONS 173±2 (6.81±0.08) 19±1 (0.75±0.04) 261±2 (10.28±0.08) 208±2 (8.19±0.08) 259±2 (10.20±0.08) 167 ± 2 TERMINALS I2 M6 2(0.079) *) - According to Eurobat (Long Life group) Ÿ 215±2 (8.47±0.08) 12 V 78 Ah / C10 6 AGM o 10~12 years @ 20 C* Design life o 8 years @ 25 C height 215,0 mm length Dimensions 261,0 mm width 173,0 mm Weight ~26,0 kg 78,0 Ah 10h 7,8A @1,75V/cell 74,0 Ah 5h 14,8A @1,75V/cell Capacity o 53,8 Ah 1h 53,8A @1,75V/cell @ 25 C 46,5 Ah 0,5h 97,0A @1,60V/cell o o charge Ambient nominal 0 C ~ 40 C o o temperature discharge -20 C ~ 50 C range o o storage -20 C ~ 40 C Internal resistance @ fully charge battery £4 mW 13,5V to 13,8V standby use o (-18 mV/ C) Charging voltage o @ 20 C 14,4 V to 15,0V cycle use o (-24 mV/ C) recommended 7,8 A Charging current maximum 23,4 A Maximum discharge current (for 5 sec) 800 A after 1 month Capacity retention 97 % o after 6 months 80 % during storage @ 20 C after 12 months 63 % (self discharge) standard ABS UL 94-HB Container material optional ABS UL 94-V0** Terminal insert terminal I2 Terminal hardware initial torque 5,5 Nm 200±2 (7.88±0.08) Nominal voltage Nominal capacity Cell per unit Technology **) - Flame-retardant NO TRANSPORT RESTRICTED Not restricted for air, surface and water transport. Classified as nonhazardous material (IATA/ICAO Special Provision A67, DOT-CFR Title 49 parts 171-189, IMDG amendment 27) DISCHARGE CHARACTERISTICS o o • Constant current (Current [A], 25[ C] / 77[ F]) F.V. V/cell 1,80 1,75 1,70 1,65 1,60 5 min 258,0 283,0 301,0 313,0 323,0 10 min 179,0 193,0 201,0 207,0 211,0 15 min 147,0 155,0 160,0 164,0 167,0 o 30 min 90,00 93,00 95,00 96,00 97,00 50 min 61,00 62,00 63,00 64,00 64,00 1hr 52,90 53,80 54,40 54,90 55,30 2hr 30,10 30,50 30,80 31,10 31,30 4hr 16,14 16,42 16,56 16,64 16,68 6hr 11,93 12,10 12,18 12,21 12,23 Discharge time 8hr 10hr 9,31 7,60 9,44 7,80 9,50 7,80 9,52 7,80 9,53 7,80 50 min 121,1 123,8 125,3 126,5 127,5 1hr 104,8 106,6 108,0 109,0 109,8 2hr 60,20 61,00 61,60 62,20 62,60 4hr 32,28 32,85 33,11 33,28 33,42 6hr 23,86 24,21 24,35 24,42 24,47 Discharge time 8hr 10hr 18,61 15,20 18,89 15,60 18,99 15,60 19,04 15,60 19,06 15,60 o • Constant power (Power [W/cell], 25[ C] / 77[ F]) F.V. V/cell 1,80 1,75 1,70 1,65 1,60 5 min 461,8 517,5 552,0 575,0 591,5 10 min 339,3 364,0 379,5 391,3 398,5 15 min 282,0 298,3 307,8 315,1 320,0 30 min 179,1 184,0 186,8 189,0 190,8 F.V. - Final voltage www.europower.eu UPS UPS 12-80 Battery life characteristics of standby use Battery life characteristics of cycle use 14 Temperature: o o 25[ C] / 77[ F] 12 Charging voltage: 2.275 V/cell 120 10 100 Retention Capacity [%] Life Expectancy [year] 8 6 4 2 80 60 80[%] 100[%] Depth of discharge D.O.D 50[%] D.O.D 30[%] D.O.D 40 20 0 20 68 30 86 40 104 0 o 50 122 [ C] o [ F] 0 300 600 900 1200 1500 Numbers of cycles Battery Temperature Battery discharge characteristics Battery self discharge characteristics 100 13.0 Temperature: o o 25[ C] / 77[ F] Capacity Retention Ratio [%] Terminal Voltage [V] 12.0 11.0 14.8[A] 7.8[A] 10.0 22[A] 30.5[A] 55[A] 9.0 8.0 323[A] 211[A] 273[A] 167[A] 7.0 1 2 3 5 10 o o 5[ C]/41[ F] 60 40[oC]/104[oF] 30[oC]/86[oF] 20[oC]/68[oF] 40 78[A] 20 30 80 60 2 3 5 [min] 10 20 30 0 2 4 6 8 10 12 14 16 18 20 Storage time [months] [hr] Discharge time 0.15 0.12 0.09 0.06 Charge voltage Charge vo 13.0 lume 12.0 15.0 120 0.18 14.0 100 11.0 10.0 60 40 0.03 20 0.12 0.09 0.06 100 12.0 80 Discharge 100% (0.05C[A] x 20[h]) 50% (0.05C[A] x 10[h]) Charging constant voltage: 2.45[V/cell] constant current: 0.1C[A] Temperature: 20[oC](68[oF]) 11.0 10.0 0 0 10 15 20 Charge time [hr] 40 20 Charge current 0 5 60 0.03 Charge current 0 lume 13.0 0.15 140 120 Charge vo 80 Discharge 100% (0.05C[A] x 20[h]) 50% (0.05C[A] x 10[h]) Charging constant voltage: 2.275[V/cell] constant current: 0.1C[A] Temperature: 20[oC](68[oF]) Charge voltage Charge volume [%] 14.0 0.21 Charge voltage [V] 0.18 140 Charge current [CxA] 15.0 Battery charging characteristics for the cycle use Charge volume [%] 0.21 Charge voltage [V] Charge current [CxA] Battery charging characteristics for the standby use 0 25 0 0 0 5 10 15 20 Charge time [hr] 25 Battery discharge current and final discharge voltage Discharge current [A] Final discharge voltage [V/cell] 16 > I 16 £ I < 40 40 £ I < 80 80 £ I 1.75 1.70 1.55 1.30 Pb *) C - Capacity Date of issue: 30.10.2006; change number: 3; date of change: 24.09.2014 www.europower.eu UPS