DGM01 – SERVER GATEWAY –
DALCNET SRL
FW 2.3.3 Gateway ETHERNET-MODBUS-DMX
Registered Office: via Bassone, 22 - 37139 Verona (VR) - Italy Headquarters: via Meucci, 35 - 36040 Brendola (VI) - Italy Tel. + 39 0444 1836680/1867452 Fax. + 39 0444 1867453 VAT: IT-04023100235
[email protected] www.dalcnet.com
+RDM-DALI
Made in Italy rev. 2015-05-20 pag. 1/4
Datenblatt - Data Sheet
EIGENSCHAFTEN FEATURES • Versorgungsspannung Supply Voltage
12-24-48V DC
• Bus ETHERNET • Bus Modbus • Bus DMX 512 • Bus DALI
10/100 Mbit RTU, from 9600 to 250K baud 512 slots NSC, SIP, RDM 64 channels, buit in 125mA power supply
Bezugsnormen - Reference Standards IEC 61547
Equipment for general lighting purposes - EMC immunity requirements
IEC 61000-3-2
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
EN 55015
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
IEC/EN 62386-101 IEC/EN 62386-102
Digital addressable lighting interface - Part 101: General requirements - System Digital addressable lighting interface - Part 102: General requirements - Control gear
IEC/EN 62386-207
Digital addressable lighting interface - Part 207: Particular requirements for control gear - LED modules (device type 6) Entertainment Technology - Lighting Control Systems - 0 to 10V Analog Control Specification
ANSI E 1.3 ANSI E1.11 ANSI E1.20
Entertainment Technology - USITT DMX512-A - Asynchronous Serial Digital Data Transmission Standard for Controlling Lighting Equipment and Accessories Entertainment Technology-RDM-Remote Device Management over USITT DMX512 Networks
-
MODBUS APPLICATION PROTOCOL SPECIFICATION V1.1b
Technische Angaben - Technical Specifications Versorgungsspannung - Supply Voltage
min: 10.8 VDC .. max: 50,2 VDC
Eingangsstrom - Input Current Spanng. / voltage
min
typ*
bei / at 12VDC
110mA (1,2W)
320mA (3,84W)
bei / at 24VDC
60mA (1,44W)
160mA (3,84W)
bei / at 48VDC
40mA (1,92W)
80mA (3,84W)
max 500mA
*ethernet and all bus at full load Lagerungstemperatur - Storage temperature
min: -40 max: +60 °C
Betriebstemperatur - Working temperature
min: -40 max: +40 °C
Schutzart - Protection Grade Gewicht - Weigth Abmessungen - Mechanical dimensions ETHERNET MODBUS RTU
ALUMINIUM BOX: IP20 - PLASTIC BOX IP10 ALUMINIUM BOX: 230g - PLASTIC BOX 125g ALUMINIUM BOX: 105x70x47 - PLASTIC BOX: DIN RAIL 4mod. 10/100 Mbit baseT FULL DUPLEX AUTO NEGOTIATION RS-485, from 9600 to 250kbaud
DMX
NSC 512 slots Max units: 32 standard or 128 DALCNET (it depends on the wiring) open fail safe - short fail safe
DALI
Max 64 units, buit-in 125mA power supply
CONTROLLERS
DGM01 – SERVER GATEWAY –
DALCNET SRL
FW 2.3.3
Registered Office: via Bassone, 22 - 37139 Verona (VR) - Italy Headquarters: via Meucci, 35 - 36040 Brendola (VI) - Italy Tel. + 39 0444 1836680/1867452 Fax. + 39 0444 1867453 VAT: IT-04023100235
[email protected] www.dalcnet.com
Made in Italy
Gateway ETHERNET-MODBUS-DMX+RDM-DALI
rev. 2015-05-20 pag. 2/4
Datenblatt - Data Sheet
Verdrahtung - Installation Anschlussblock - Terminal block Pin 1
Vin+
2
VinVin
3
L NPE 230V
ETH BUS1 BUS2 BUS3
IN 0V 5V
ETHERNET
RST
PUSH N.O.
DC IN +
-
+
-
C
6
DC In : 12 ÷ 48 V Range : -40 ÷ +60 °C DALI supply : 125mA
SWITCHING 12V / 24V / 48V
Vin-
5
SERVER GATEWAY DGM01-1248
BUS1 RTU C B A
Vin+
4
Modbus 1
7
B
DMX 1
A
8
BUS2 BUS3 DMX DALI COM D- D+ DA+ DA-
Com
D+
C
9
Modbus 2
10
D-
Com
B
DMX 2
A
DD+
11
DA+ DALI
12
DA-
er connection :
Vout
+ -
a.
230VAC à LED drivers à LEDs (in my case DC Load)
b. DGM01-1248 powered with 12-48V DC. So another power supply 230VAC à 12-48VDC (any value between these limits) 3 21
DMX AUSGANG - OUT
2) Control connection: PC with web browser à Local LAN (Ethernet) à DGM01-1248 Ethernet input à DGM01-1248 DALI output à LED drivers DALI control ETHERNET (Plug 8P8C) Pin RJ45/A (RJ45/B crossed) RJ45/B (RJ45/A crossed) 1
White/Green
White/Orange
2
Green
Orange
3
White/Orange
White/Green
4
Blue
Blue
5
White/Blue
White/Blue
6
Orange
Green
7
White/Brown
White/Brown
8
Brown
Brown
Konfiguration
Configuration
RST SCHALTER:
RST BUTTON:
drücken für < 0,5 Sek = Neustart & zum Startprogramm schalten drücken für > 4 Sek = Werksstandard
pressed for < 0.5s = reboot & switch to bootloader pressed for > 4s = factory default
STANDARD IP ADRESSE: 192.168.1.4
DEFAULT IP ADDRESS: 192.168.1.4
LEDs: LED
FUNCTION
ON
BLINK
FAST BLINK
OFF
LED1 (top)
Ethernet
OK
No communication
-
Error
LED2
BUS1 (DMX/RTU)
OK
No communication
-
Error
LED3
BUS2 (DMX/RTU)
OK
No communication
-
Error
LED4 (bottom)
BUS DALI
OK
No communication
-
no power or short circuit
CONTROLLERS
DALCNET SRL Registered Office: via Bassone, 22 - 37139 Verona (VR) - Italy Headquarters: via Meucci, 35 - 36040 Brendola (VI) - Italy Tel. + 39 0444 1836680/1867452 Fax. + 39 0444 1867453 VAT: IT-04023100235
[email protected] www.dalcnet.com
DGM01 – SERVER GATEWAY –
FW 2.3.3
Made in Italy
Gateway ETHERNET-MODBUS-DMX+RDM-DALI
rev. 2015-05-20 pag. 3/4
Datenblatt - Data Sheet
Lokaler Taster – LOCAL BUTTON: Das Gerät hat einen lokalen Kontakt (Schließer), welcher die Verwendung im Stand-Alone-Modus ermöglicht. Diese Funktion, zusätzlich dazu, eine weitere Möglichkeit zu sein, um die Spotlights zu verwalten, ist besonders nützlich, um einen lokalen Test des Gerätes und Armaturen, die damit verbunden sind, durchzuführenGLHAn/Aus'LPPHU-)XQNWLRQGHU 6FKHLQZHUIHULP6HQGXQJVPRGXV]XPDFKHQ The device has a local contact (N.O.) which allows the use in stand-alone mode. This function, in addition to being a further possibility to manage the spot lights, is particularly useful to carry out a local test of the device and fixtures that are connected with, making on/off/dimmer function of the spot lights in broadcasting mode. 7DVWHU key
)XQNWLRQ function Kurz tasten Zweimal kurz tasten Langes Drücken (>1s) im ausgeschalteten Zustand Langes Drücken (>1s) im eingeschalteten Zustand
On/Off Maximale Intensität Einschalten bei 10% (nachts) Dimmer hoch/runter
Click Double Click Long pressing (>1s) from OFF Long pressing (>1s) from ON
ON/OFF Maximum intensity Turn ON at 10% (night) Dimmer UP/DOWN
6SHLFKHU)XQNWLRQ: 'DV*HUlWVSHLFKHUWVHLQHQ6WDWXVbeiStromaXVIDOO7DVWHUYHUEXQGHQPLW9 Memory Function: If power is restored the device to be switched off again. (cR)XQNWLRQ'DV*HUlWZLUGZLHGHULQ%HWULHEJHQRPPHQ bei Stromausfall 7DVWHUYHUEXQGHQPLW9 Eco Function:The device starups turnedoff in the event of blackout (buttons connected to 0V). 3UHVHW)XQNWLRQDas Installationsprogramm speichert den voreingestellten Status (Tasten verbunden mit 5V während der Installation, neben 0V). Das Gerät beginnt beim Voreinstellen im Falle eines Stromausfalls. Preset Function: The installer stores the preset status (buttons connected to 5V during installation, next to 0V). The device starts from the preset in the event of blackout. *connect to 5V = MEMORY *connect to 0V = NO-MEM
8 ETHERNET
SERVER GATEWAY DGM01-1248
3 2 1 0V 5V INPUT
DC IN -
+
-
C
BUS1 RTU B A
BUS2 DMX COM D-
x100 x10 x1 ADDRESS
DA+ DA- N.C.
DALI
LED DIMMER DLB1248
DC In : 12 ÷ 48 V Range : -40 ÷ +60 °C DALI supply : 125mA
+
C
RST
PUSH N.O.
230V
8
IN 0V 5V
4
L N PE
ETH BUS1 BUS2 BUS3
0 4
C
0 4
C
0
8
push n.o.
DC In : 12-48V Out : CC/CV Range : -40°C ÷ +60°C
BUS3 DALI D+ DA+ DA-
DC IN
+
-
+
-
N.C. N.C. L1
+
OUT L1 L2
-
+
L2
-
L3
+
L3
-
SWITCHING SUPPLY
Vout
+-
CONTROLLERS
DALCNET SRL Registered Office: via Bassone, 22 - 37139 Verona (VR) - Italy Headquarters: via Meucci, 35 - 36040 Brendola (VI) - Italy Tel. + 39 0444 1836680/1867452 Fax. + 39 0444 1867453 VAT: IT-04023100235
[email protected] www.dalcnet.com
DGM01 – SERVER GATEWAY –
FW 2.3.3 Gateway ETHERNET-MODBUS-DMX +RDM-DALI
Datenblatt - Data Sheet
Made in Italy rev. 2015-05-20 pag. 4/4
Technische Hinweise - Technical Notes • Für die spezifischen Funktionen der Bus- oder lokalen Befehle, siehe die Hersteller-Webseite. • Der 0-10V Steuereingang ist kompatibel mit einer sinkenden/beziehenden 0-10V Steuerung. Dieses Produkt bietet keine Stromquelle. • Installation und Wartungsarbeiten dürfen nur durch qualifiziertes Personal unter Beachtung der geltenden Vorschriften durchgeführt werden. • Das Produkt muss in einem elektrischen Panel mit Überspannungsschutz installiert werden. • Eine SELV Stromversorgung ist vorzuziehen. Falls eine Schutzklasse I Stromversorgung verwendet wird, müssen alle Punkte des PE (Erdschlussschutz) mit einem zertifizierten und zulässigen Schutzleiter verbunden sein. • 230V Kabel müssen vom Niederspannungskreislauf (SELV) und von jeglicher Verbindung mit diesem Produkt ferngehalten werden. • Für die Verbindung sollten abgeschirmte und verdrillte Kabel und nicht mehr als eine Länge von 10m verwendet werden. • Um den DMX512+RDM, Modbus und DALI Bus zu verbinden, verwenden Sie, Kabel gemäß Vorgaben der jeweiligen Protokolle und Richtlinien. • Es ist absolut verboten, die 230V Netzspannung, ganz gleich aus welchem Grunde, direkt oder indirekt mit dem Bus oder jeglichen anderen Teilen des Stromkreises zu verbinden. • For the specific functions of bus or local commands, refer to the function handbook available on the manufacturer's website. • The 0÷10V control input is compatible with sinking/sorcing 1÷10V controls. This product does not provide current sourcing. • Installation and maintenance must be performed only by qualified personnel in compliance with current regulations. • The product must be installed inside an electrical panel protected against overvoltages. • For the power supply is preferable to use a SELV power supply. In the case of using class I power supply, ALL points of the protective earth (PE = Protection Earth) must be connected to a valid protection earth . • Keep 230V cables separate from circuits to low voltage (SELV) and from any connection with this prouct. • The connection cables between the power source "low voltage" and the product must be dimensioned correctly and they should be isolated from every wiring or parts at voltage not SELV. Is preferable to use shielded and twisted cables.(Only for multi-channel) In case of output currents higher at 10A, connect at the power supply both pairs of power supply input "V +" and "V-". • The length of the connection cables between the product and the LED module must be less than 10m; the cables must be dimensioned correctly and they should be isolated from every wiring or parts at voltage not SELV. Is preferable to use shielded and twisted cables. • The length of the connection cables between the local commands (push-button, potentiometer, 0-10 V, 1-10 V, or other) and the product must be less than 10m; the cables must be dimensioned correctly and they should be isolated from every wiring or parts at voltage not SELV. Is preferable to use shielded and twisted cables. • The length and type of the connection cables of the BUS (DALI, DMX, Modbus, Ethernet, or other) use cables as per specification of the respective protocols and regulations and they should be isolated from every wiring or parts at voltage not SELV. Is preferable to use shielded and twisted cables. • To connect the DMX512+RDM, Modbus and DALI bus use cables as per specification of the respective protocols and regulations. • It's absolutely forbidden to connect, for any reason whatsoever, directly or indirectly, the 230V mains voltage to the bus or to other parts of the circuit.