Notes ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P2 teamserver M851i/861i------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P7 teamserver M850i/860i------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P8 teamserver M850ic ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P10 teamserver M840i ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P12 teamserver L800i series --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P14 teamserver G800i series--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P15 teamserver C800i series --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P16 teamserver C300i series --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P17 teamserver Internal Devices ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P18 teamserver External Devices --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P19 teamserver Rackmount ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P20 teamserver Network Cards-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P21 teamserver Cluster System configuration(U.S.only) ---------------------------------------------------------------------------------------------------------------------------------------------------P21 Hardware ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P22
Index
Key to
The numbers on the left hand side of each page correspond to the various options available with teamservers as follows : CPU slot RAM module slot 3.5 inch HDD Bay 5 inch Bay RS-232C PCI slot ISA slot Redundant PSU Others
Or
1
And
NOTES This System Configuration Guide (V.3) introduces new PentiumIII 500MHz models, G870i and C870i and withdraws all old models. The shipment of G870i and C870i commences at End/March and End/April respectively. Please refer to http://www.fujitsu.co.jp/hypertext/InfoPro/mspl/teamserver/config.html for old models.
Upgrade 4way to 8way (June 1999) Upgrade kit is required to expand CPU nodes on M850i/860i ■ CPU Cabinet Upgrade Kit
*Available from June 1999 When upgrading from 4way pedestal system to 8way, rackmounting is required.
To connect additional internal Storage (M800i) SCSI Card or RAID Card is required to connect hard disks. Onboard SCSI can be used to connect to SCSI devices in 5inch bays. A SCSI Card (GP5-125) is required to mount DLT(GP5-DL351),Tape unit(GP5-ML301). Storage System (GP5UR1DC2,GP5UR1DC3) is required when more than 7HDDs are installed. 14HDDs in total can be mounted in a Pedestal. A SCSI Card (GP5-126) is required to connect up to four HDDs in an Ultra2 wide Storage System (GP5URIDC3) Therefore, two sets of SCSI Card and Cable are required to connect more than five HDDs in a Storage System.
How to mount internal HDDs (L800i/G800i) 18.2GB HDD cannot be mounted in bay #7 and #8. However 4.3GB / 4.5GB / 9.1GB HDD can be mounted in all bays.
Restriction of Operating System (M800i) Windows NT Server 4.0 supports up to 4CPUs and 4GB of memory. Windows NT Server 4.0 Enterprise Edition is required for more than 4 CPUs and 4GB of Memory.
Mounting additional memory (M851i/861i) Memory expansion must be performed in bank units by mounting four similar capacity DIMMs in one bank. Memory expansion must be performed by mounting bank units in ascending order of memory capacity alternatively on Master and Slave node.
(M840i/850ic/850i/860i) Memory must be expanded in bank units by mounting four similar capacity DIMMs in one bank. Memory is expanded in bank units by mounting DIMMs in ascending order of memory capacity alternately on two RAM base cards.
(L800i) Mount the same capacity DIMM's in units of four. (Mounting of DIMM's with different capacities or a set of less than four DIMM's is not allowed) Mount the DIMM's in ascending order of their capacity. Use DIMM slots in the order from bank A (J1 to J4) to bank B (J5 to J8), bank C (J9 to J12), and bank D (J13 to J16)
(G800i/C800i,C300i) The mother board has four slots for RAM modules (including standard equipment), Please install RAM modules in the order of the slot number. (teamserver C3xxi has three slots)
2
NOTES S.M.A.R.T. function S.M.A.R.T. function is available in the combinations below:
■ : Corresponds , x:Does not correspond , -:N/A
Internal Hard disk units IDE Models
Hard disk cabinet
SCSI Hard disks
GP5UR1DC2
GP5UR1DC3
GP5MS621A
Standard Standard SCSI card RAID card SCSI card RAID card SCSI card RAID card SCSI/RAID card equipment equipment GP5-125 GP5-126 GP5-144 GP5U141 GP5-143 GP5U142 GP5U121 GP5-125 GP5U141 GP5-126 GP5-144 GP5U121/-125/U141 IDE SCSI
C300i
■
-
x
-
-
x
■
x
-
■
x
-
-
x
C800i
-
■
-
-
-
x
■
x
x
-
x
-
-
x
G800i
-
■
-
-
■
x
-
x
-
■
x
■
■
x
L800i
-
■
-
-
■
x
-
-
-
■
x
■
■
x
M800i
-
-
-
■
■
x
-
-
-
■
x
■
■
x
M831/851/861i
-
-
-
■
■
x
-
-
-
■
x
■
■
-
Additional bus-slots The number of bus-slots which can be used depends on each model. models
Number of standard bus-slots
Product ID
REMARKS
M8x1i
PCI(64bit)x10 PCI(32bit)x11 PCI/ISA(32bit)x1
GP5M851LR GP5M861LR
LAN card is mounted in a PCI(32bit)slot.
M800i / M800ic
PCI(64bit)x5 PCI(32bit)x5 PCI/ISA(32bit)xl
GP5M850L GP5M860L GP5M850AL GP5M840L
GP5M850LR GP5M860LR GP5M850BL GP5M840LR
LAN card is mounted in a PCI(32bit)slot.
L800i
PCIx6 PCI/ISAx1
GP5L820L GP5L830L GP5L840L GP5L850L
GP5L820LR GP5L830LR GP5L840LR GP5L850LR
LAN card is mounted in a PCI(32bit)slot.
G800i
PCIx4 PCI/ISAx1 ISAx1
GP5G820L GP5G850L GP5G870L
GP5G820LR GP5G850LR GP5G870LR
All of the slots are available
C800i
PCIx3 ISAx2
GP5C810 GP5C821 GP5C850 GP5C870
GP5C810R GP5C821R GP5C850R GP5C870R
All of the slots are available
C300i
PCIx4 ISAx1
GP5C300 GP5C310 GP5C320
All of the slots are available
3
NOTES Number of mountable optional cards
M831i/851i/861i Cards
Product ID
RAID card GP5U141 (Ultrawide SE) RAID card (Ultra2wide LVD)
M820i/830ic/830i/840i/850ic/850i/860i Bus
Maximum number of cards mounted
Total
PCI64
6
10
REMARKS
Bus
Maximum number of cards mounted
Total
RAID card GP5U141 (Ultrawide SE)
PCI64
4
5
RAID card GP5-144 (Ultra2wide LVD)
PCI64
5
Cards
GP5U141 and GP5-144 cannot be used in the same platform
Product ID
GP5U141 and GP5-144 cannot be used in the same platform
GP5-144
PCI64
6
SCSI card GP5-125 (Ultrawide SE)
PCI64
9
SCSI card (Ultrawide SE) GP5-125
PCI64
4
SCSI card (Ultra2wide LVD)
PCI64
10
SCSI card (Ultra2wide LVD) GP5-126
PCI64
5
2
SCSI card (Ultrawide Diff)
PCI64
2
Fibre Channel GP5-FC101 card
PCI64
2
LAN card
GP5-183
PCI64
1
LAN card
GP5-182
PCI32
3
LAN card
Standard equipment
PCI32
1
Server Monitor Module
GP5USM102
PCI32
1
1
Product ID
Bus
Maximum number of cards mounted
Total
SCSI card (Ultrawide Diff)
GP5-123
PCI
2
SCSI card (Ultrawide SE)
GP5-125
PCI
3
SCSI card (Ultrawide Diff)
GP5-126 GP5-123
PCI64
Fibre Channel GP5-FC101 card
PCI64
2
LAN card
GP5-183
PCI64
1
LAN card
GP5-182
PCI32
3
LAN card
Standard equipment
PCI32
1
Server Monitor Module
GP5USM102
For external disk array 2
4
Mounted in PCI slot3(fixed)
PCI32
1
Bus
Maximum number of cards mounted
1
L800i Product ID
SCSI card (Ultrawide Diff)
GP5-123
SCSI card (Ultra2wide LVD)
For external disk array 2
4
Mounted in PCI slot3(fixed)
G800i
Cards
SCSI card (Ultrawide SE)
GP5-123
REMARKS
GP5-125
PCI
2
Total
3
3
PCI
3
PCI
RAID card GP5U141 (Ultrawide SE)
PCI
2
RAID card (Ultra2wide LVD)
PCI
3
GP5-144
Cards
For external disk array
7* GP5-126
REMARKS
Fibre Channel GP5-FC101 card
PCI
2
LAN card
GP5-183
PCI
1
LAN card
GP5-182
PCI
3
Use for internal/external SCSI devices
GP5U141 and GP5-144 cannot be used in the same platform
Mounted only in PCI-A2
For external disk array
Use for internal/external SCSI devices
3
SCSI card GP5-126 (Ultra2wide LVD)
PCI
3
RAID card (Ultrawide SE)
GP5U141
PCI
2
RAID card (Ultrawide)
GP5U142
5
PCI
1
RAID card GP5-144 (Ultra2wide LVD)
PCI
3
Fibre Channel GP5-FC101 card
PCI
2
REMARKS
Internal/external array cofiguration
Only for internal array configuration GP5-144 cannot be used with other RAID card in the seme platform
LAN card
GP5-183
PCI
1
LAN card
GP5-182
PCI
3
SMM
GP5USM102
PCI
1
Product ID
Bus
Maximum number of cards mounted
RAID card GP5U141 (Ultrawide SE)
PCI
2
RAID card GP5U142 (Ultrawide SE)
PCI
1
RAID card (Ultrawide SE) GP5-143
Only for internal array configuration (Cannot be used with GP5-143)
PCI
1
Only for internal array configuration (Cannot be used with GP5U142)
GP5-125
PCI
3
Use for internal/external SCSI devices
GP5-182
PCI
3
3
GP5USM102
PCI
1
1
4 LAN card
Standard equipment
PCI
1
SMM
GP5USM102
PCI
1
Mounted in PCI-A1(fixed) Mounted only in PCI-A3
* Up to six cards can be mounted when an ISA card is used.
C800i
C300i Product ID
Bus
Maximum number of cards mounted
RAID card (Ultrawide SE)
GP5U141
PCI
2
RAID card (Ultrawide SE)
GP5U142
PCI
1
Cards
RAID card (Ultrawide SE) SCSI card LAN card LAN card
SMM
Total
REMARKS
Internal/external array configuration 2 1
3
Only for internal array configuration (Cannot be used with GP5-143)
GP5-143
PCI
1
Only for internal array configuration (Cannot be used with GP5U142)
GP5U121
PCI
2
Only for external SCSI devices
GP5-183
PCI
1
GP5-182
PCI
3
GP5USM102
PCI
1
Cards
SCSI card LAN card
SMM
4
Total
3
REMARKS
Internal/external array configuration
NOTES Disk array configuration • Physical pack • Logical drive • Partition
• • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • • • • ••
A collection of physical HDDs comprising a RAID System. Logical drive (ex. D: ) seen by the Operating System. One of the logical access units into which a logical drive is divided.
Physical pack HDD
HDD
HDD
HDD
Logical drive A Logical drive B
Partition 1
* Drives can be divided into partition.
Partition 2
Logical drive C
(1) Physical pack must be comprised of the same type of HDDs. (2) Maximum logical drive size is 2TB (GP5U141/142). (3) The number of HDDs comprising a physical pack is as shown below.
RAID Level
Discription
RAID 0
)
The data is broken down into blocks,each on a
RAID 1
)
Duplicates the disk and writes the same data
RAID 5
)
separate disk drive
onto two disks.
HDDs
Capacity of logical drives
(
2~8
The capacity of logical drive is same as the
(
2
The capacity of the logical drive is half the
3~8
The capacity of each logical drive is the number
The data is broken down into blocks and each blocks is written together with parity bits on a separate disk drive.
(
capacity of connected HDD.
capacity of connected HDD.
(4) The same RAID level must be used when dividing a physical pack into a number of logical drives. (5) A physical pack must comprise only of HDDs which are connected by the same RAID card. (6) A RAID card can support more than one physical pack. ( even if different RAID levels) (7) Internal and external array devices cannot be connected to the same RAID card. (except for M8xx ~)
5
of connected HDDs - 1.
NOTES Hard disk cabinet/RAID card/SCSI card ●Hard disk cabinet GP5MS621A: Up to two can be connected Operating System has to be installed on an internal hard disk.
●RAID card (GP5U141/GP5-144) Up to two Hard disk cabinets can be connected with one RAID card. Internal disks and Hard disk cabinets (in array configuration) cannot be connected to the same RAID card.
●RAID card (GP5U142/GP5-143) Only for use with internal devices. Only one RAID card can be used per a server.
●SCSI card (GP5U121/GP5-125/GP5-126) Internal and external devices cannot be connected to the same SCSI card. Maximum number of daisy chain connection allowed : (1) Up to four external devices (but not Hard disk cabinets) can be connected by daisy chain. (2)Only one Hard disk cabinet can be connected. (Daisy chain connection is not available)
6
System Configuration teamserver M851i/861i (June 1999)
CPU : Pentium®II Xeon™ (450MHz) ✕2 (~8) , Cache (L1+L2) : 32KB+1MB/2MB, Internal Hard disk bay : 12slots (Hot plug), CD-ROM , LAN Card (std.), Intel LANDesk®Server Manager, Redundant power supply (option), Redundant Fan (std.) , 19inch Rack (Display, Keyboard, Hard Disk Cabinet and UPS have to be purchased separately) GP5M851LR
[2CPU / Rackmount Type] 2CPU(Cache:1MB) , Memory : 512MB (ECC) , HDD : Option
GP5M861LR
[2CPU / Rackmount Type] 2CPU(Cache:2MB) , Memory : 512MB (ECC) , HDD : Option
teamserver M851i / M861i Configuration teamserver M851i / M861i consists of a master node and a slave node. CPU Master Node Slave Node
Std. Max. Std. Max.
1 4 1 4
Memory 256MB (64MB✕4) 8GB (256MB✕32) 256MB (64MB✕4) 8GB (256MB✕32)
3.5 inch HDD
5 inch Bay
109.2GB (18.2GB✕6bays) 109.2GB (18.2GB✕6bays)
1 (CD-ROM) 4 4
PCI (32bit) 1 (LAN Card) 5 6
Expansion slots PCI (64bit) ISA / PCI (32bit) 5 1 5 0
Power Supply Unit 2 3 2 3
NOTE : - The addition of Hard disks requires a SCSI Card. - Hard disk duplexing requires two SCSI Cards.
CPU
CPU Field Upgrade Kit Pentium®II Xeon 450MHz (2MB) ✕1 GP5-FG1OM (for M861i)
q
CPU Field Upgrade Kit Pentium®II Xeon 450MHz (1MB) ✕1 GP5-FG1OK(for M851i)
Memory
Max : 16GB Additional Memory -256MB (64MB-DIMM✕4) GP5-RM25G
w
Standard memory : 512MB (64MB-DIMM✕4✕2sets) Additional Memory - 512MB (128MB-DIMM✕4) GP5-RM51G
Additional Memory - 1024MB (256MB-DIMM✕4) GP5-RM1G
Hard Disk Drive (1)Disk Addition / Duplexing (Up to 12 disks in a teamserver)
y
Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45
SCSI Card (Ultra2 Wide.) GP5-126
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82
(2)Internal Disk Array
y
RAID Card (Cache : 16MB) GP5U141
Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45
y
RAID Card (Cache : 32MB, Ultra2 . Wide SCSI) GP5-144
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94
y
Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81
Server Monitor Module GP5USM102
Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82
Others
i
Redundant Power Supply Unit GP5UPU141
7
System Configuration teamserver M850i / 860i (Feb.1999) teamserver M860i / 850i CPU : Pentium®II Xeon™ (450MHz) ✕1 (~4, max : 8) , Cache (L1+L2) : 32KB+1MB/2MB , Internal Hard disk bay : (Hot plug) 14slots (Pedestal) / 6slots (Rackmount) , CD-ROM , LAN Card (std.) , Intel LANDesk®Server Manager , Redundant Power Supply (Option), Redundant Fan (std.) GP5M850L GP5M860L
[1CPU / Pedestal Type] 1CPU, (Cache:1MB), Memory : 256MB (ECC) , HDD : Option [1CPU / Pedestal Type] 1CPU, (Cache:2MB), Memory : 256MB (ECC) , HDD : Option
[Pedestal type] GP5M850LR GP5M860LR
[1CPU / Rackmount Type] 1CPU (Cache:1MB), Memory : 256MB (ECC) , HDD : Option [1CPU / Rackmount Type] 1CPU (Cache:2MB), Memory : 256MB (ECC) , HDD : Option
[Rackmount type]
8way Upgrade
CPU Cabinet Upgrade Kit GP5U86L2(for 2 MB cache) ❋When you upgrade to 8 way, rackmounting is required. Please consult your sales representative. (June 1999)
o
CPU Cabinet Upgrade Kit GP5U85L1(for 1 MB cache) ❋When you upgrade to 8 way, rackmounting is required. Please consult your sales representative. (June 1999)
CPU CPU Field Upgrade Kit Pentium®II Xeon™-450MHz (2MB) ✕1 GP5-FG10M (for M860i)
q
CPU Field Upgrade Kit Pentium®II Xeon™-450MHz (1MB) ✕1 GP5-FG10K (for M850i)
Memory
Max. memory: 8GB
Additional Memory - 256MB (64MB-DIMM✕4) GP5-RM25G
w Standard memory : 256MB (64MB-DIMM✕4)
Additional Memory - 512MB (128MB-DIMM✕4) GP5-RM51G
Internal Hard Disk ❋Pedestal Type : Up to 14 (6 in standard, 8 in optional Storage System) disks can be installed. Rackmount Type : Up to 6 disks can be installed in a rackmount type node.
Additional Memory - 1024MB (256MB-DIMM✕4) GP5-RM1G
(1)Disk Addition / Duplexing
y
Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45
SCSI (Ultra2 Wide) GP5-126
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82 Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45
y SCSI Card (Ultra2 Wide) GP5-126
SCSI Cable GP5MU823A
Storage System GP5UR1DC3 ❋It can be inserted into M860/850i Pedestal Type.
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94
SCSI Card (Ultra2 Wide) GP5-126
SCSI Cable GP5MU823A
Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81
Secand set of a SCSI Card and a Cable is required to mount disks in 5th-8th HDD bays in a Storage System.
Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82
NOTE : Hard disk duplexing requires two SCSI Cards and a Storage System.
Redundant Power Supply Unit GP5UR1PU1
❋Please refer to P.20 for the connection of Storage System in Rackmount model.
8
System Configuration (2)Internal Disk Array Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45
y RAID Card (Cache : 16MB) GP5U141
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82 Redundant Power Supply Unit GP5UR1PU1 Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45 SCSI Cable GP5MU830A
Storage System GP5UR1DC2 ❋It can be inserted into M860/850i Pedestal model.
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82 Redundant Power Supply Unit GP5UR1PU1
Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45
y RAID Card (Cache : 32MB Ultra2 Wide SCSI) GP5-144
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82 Redundant Power Supply Unit GP5UR1PU1 Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45 SCSI Cable GP5S-832
Storage System GP5UR1DC3 ❋It can be inserted into M860/850i Pedestal model.
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81
y
Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82
Server Monitor Module GP5USM102
Redundant Power Supply Unit GP5UR1PU1
Others
i
Redundant Power Supply Unit GP5UPU141
9
System Configuration teamserver M850ic (Feb.1999) teamserver M850ic CPU : Pentium®II Xeon™ (450MHz) ✕1(~4), Cache (L1+L2) : 32KB+1MB , Internal Hard disk bay : (Hot plug) 14slots (Pedestal) / 6slots (Rackmount) , CD-ROM , LAN Card (std.) , Intel LANDesk®Server Manager , Redundant Power Supply (Option), Redundant Fan (std.) GP5M850AL
[1CPU / Pedestal Type] 1CPU, Memory : 256MB (ECC) , HDD : Option
[Pedestal type] GP5M850BL
[1CPU / Rackmount Type] 1CPU, Memory : 256MB (ECC) , HDD : Option
[Rackmount type]
CPU CPU Field Upgrade Kit (Pentium®II Xeon™-450MHz (1MB) ✕1) GP5-FG10K
q Memory
w
Max. memory: 8GB
Additional Memory - 256MB (64MB-DIMM✕4) GP5-RM25G
Standard memory : 256MB (64MB-DIMM✕4) Additional Memory - 512MB (128MB-DIMM✕4) GP5-RM51G Additional Memory - 1024MB (256MB-DIMM✕4) GP5-RM1G
Internal Hard Disk ❋Pedestal Type : Up to 14 (6 in standard, 8 in optional Storage System) disks can be installed. Rackmount Type : Up to 6 disks can be installed in a rackmount type node. (1)Disk Addition / Duplexing
y
Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45
SCSI Card (Ultra2 Wide) GP5-126
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82 Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45
y SCSI Card (Ultra2 Wide) GP5-126
SCSI Card (Ultra2 Wide) GP5-126
SCSI Cable GP5MU823A
Storage System GP5UR1DC3 ❋It can be inserted into M850ic Pedestal Type.
SCSI Cable GP5MU823A
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82
Secand set of a SCSI Card and a Cable is required to mount disks in 5th-8th HDD bays in a Storage System.
Redundant Power Supply Unit GP5UR1PU1
NOTE : Hard disk duplexing requires two SCSI Cards and a Storage System
❋Please refer to P.20 for the connection of Storage System in Rackmount model.
10
System Configuration (2)Internal Disk Array Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45
y RAID Card (Cache : 16MB) GP5U141
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82
Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45 SCSI Cable GP5MU830A
Storage System GP5UR1DC2 ❋It can be inserted into M850ic Pedestal model.
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82 Redundant Power Supply Unit GP5UR1PU1
Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45
y RAID Card (Cache : 32MB Ultra2 Wide SCSI) GP5-144
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82
Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45 SCSI Cable GP5S-832
Storage System GP5UR1DC3 ❋It can be inserted into M850ic Pedestal model.
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81
y
Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82
Server Monitor Module GP5USM102
Redundant Power Supply Unit GP5UR1PU1
Others
i
Redundant Power Supply Unit GP5UPU141
11
System Configuration teamserver M840i (Feb.1999) teamserver M840i CPU : Pentium®II Xeon™ (450MHz) ✕1 / 2 (~4) , Cache (L1+L2) : 32KB+512KB, Internal Hard disk bay : (Hot plug) 14slots (Pedestal) / 6slots (Rackmount) ,CD-ROM , LAN Card (std.) , Intel LANDesk®Server Manager, Redundant Power Supply (Option) , Redundant Fan(std.) GP5M840L [1CPU / Pedestal Type] 1CPU, Memory : 256MB (ECC) , HDD : Option
[Pedestal type] GP5M840LR
[1CPU / Rackmount Type] 1CPU, Memory : 256MB (ECC) , HDD : Option
[Rackmount type]
CPU
CPU Field Upgrade Kit-450MHz (512KB) ✕1 GP5-FG10H
q Memory
w
Max : 8GB
Additional Memory- 256MB (64MB-DIMM✕4) GP5-RM25G
Standard memory : 256MB (64MB-DIMM✕4) Additional Memory - 512MB (128MB-DIMM✕4) GP5-RM51G AdditionalMemory- 1024MB (256MB-DIMM✕4) GP5-RM1G
Internal Hard Disk ❋Pedestal Type : Up to 14 (6 in standard, 8 in optional Disk node) disks can be installed. Rackmount Type : Up to 6 disks can be installed in a rackmount type node. (1)Disk Addition / Duplexing
Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45
y SCSI Card (Ultra2 Wide) GP5-126
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82
Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45
y SCSI Card (Ultra2 Wide) GP5-126
SCSI Card (Ultra2 Wide) GP5-126
SCSI Cable GP5MU823A
Storage System GP5UR1DC3 ❋It can be inserted into M840i Pedestal Type.
SCSI Cable GP5MU823A
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81
Tow sets of SCSI cards and cables are required to mount 5th-8th HDDs in Storage System.
Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82 Redundant Power Supply Unit GP5UR1PU1
12
System Configuration
(2)Internal Disk Array
y
Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45
RAID Card (Cache : 16MB) GP5U141
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82
Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45 SCSI Cable GP5MU830A
Storage System GP5UR1DC2 ❋It can be inserted into M840i Pedestal model.
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82
Redundant Power Supply Unit GP5UR1PU1
Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45
y RAID Card (Cache : 32MB Ultra2 Wide SCSI) GP5-144
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82
Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45 SCSI Cable GP5S-832
Storage System GP5UR1DC3 ❋It can be inserted into M840i Pedestal model.
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81
y
Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82
Server Monitor Module GP5USM102
Redundant Power Supply Unit GP5UR1PU1
Others
i
Redundant Power Supply Unit GP5UPU141
NOTE ; Please reter to P.20 for rackmounting instructions.
13
System Configuration teamserver L800i series (Feb.1999) teamserver L800series CPU : Pentium®II Xeon™ (450MHz) ✕1 (~4) , Cache (L1+L2) : 32KB+512KB / 1MB , Internal Hard disk bay : 8slots (Hot plug) , CD-ROM, LAN Card (std.) On board SCSI, Intel LANdesk®Server Manager(std.) GP5L840L GP5L850L [Pedestal type]
[1CPU / Pedestal Type] 1CPU(Cache : 512KB), Memory : 128MB (ECC) , HDD : Option [1CPU / Pedestal Type] 1CPU(Cache : 1MB), Memory : 128MB (ECC) , HDD : Option
GP5L840LR GP5L850LR
[1CPU / Rackmount Type] 1CPU(Cache : 512KB), Memory : 128MB (ECC) , HDD : Option [1CPU / Rackmount Type] 1CPU(Cache : 1MB), Memory : 128MB (ECC) , HDD : Option
[Rackmount type]
CPU CPU Field Upgrade Kit - 450MHz(1MB)✕1 GP5-FG10K (for L850i)
q
CPU Field Upgrade Kit - 450MHz(512KB)✕1 GP5-FG10H (for L840i)
Memory
w
Max : 4GB
Additional Memory - 128MB (32MB-DIMM✕4) GP5-RM12G
Standard memory : 128MB (32MB-DIMM✕4) Additional Memory - 256MB (64MB-DIMM✕4) GP5-RM25G Additional Memory - 512MB (128MB-DIMM✕4) GP5-RM51G Additional Memory - 1024MB (256MB-DIMM✕4) GP5-RM1G
Internal Hard Disk (1)Disk Addition / Duplexing Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45
e ❋Up to 8 disks can be installed
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93
Bay 1~6 : 4.5GB/9.1GB/18.2GB Bay 7~8 : 4.5GB/9.1GB
Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82
Internal Disk Array
y
Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45
RAID Card (Cache : 16MB) GP5U141
y
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93
RAID Card (Cache : 32MB, Ultra2 Wide SCSI) GP5-144
Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81
y
Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82
Server Monitor Module GP5USM102
Others
i
Redundant Power Supply Unit GP5UPU131
14
System Configuration teamserver G800i series (Jan.1999) tearserver G800i series CPU : Pentium®III (500MHz) / Pentium®II (450MHz / 400MHz / 350MHz)✕1(~2) , Cache (L1+L2) : 32KB+512KB, Internal Hard disk bay : 8slots (Hot plug) , CD-ROM , On board LAN / On board SCSI, Intel LANDesk®Server Manager(std), Redundant Power Supply(option), Redundant Fan(std.) GP5G870L GP5G850L [Pedestal type]
GP5G820L
[1CPU / Pedestal Type] (March / 99) 1CPU(Pentium®III 500MHz), Memory : 64MB (ECC) , HDD : Option [1CPU / Pedestal Type] 1CPU(Pentium®II 450MHz), Memory : 64MB (ECC) , HDD : Option [1CPU / Pedestal Type] 1CPU(Pentium®II 400MHz), Memory : 64MB (ECC) , HDD : Option
GP5G870LR GP5G850LR GP5G820LR
[Rackmount type]
[1CPU / Rackmount Type] (March / 99) 1CPU(Pentium®III 500MHz), Memory : 64MB (ECC) , HDD : Option [1CPU / Rackmount Type] 1CPU(Pentium®II 450MHz), Memory : 64MB (ECC) , HDD : Option [1CPU / Rackmount Type] 1CPU(Pentium®II 400MHz), Memory : 64MB (ECC) , HDD : Option
CPU ®
q ®
®
Memory
w
Max : 2GB
CPU Field Upgrade Kit (Pentium®III-500MHz (512KB) ✕1) GP5-FG10N (for G870i) CPU Field Upgrade Kit (Pentium®II-450MHz (512KB) ✕1) GP5-FG10G (for G850i) CPU Field Upgrade Kit (Pentium®II-400MHz (512KB) ✕1) GP5-FG10C (for G820i)
Additional Memory - 64MB (64MB SDRAM-DIMM✕1) GP5-RM64F
Standard memory : 64MB (64MB SDRAM-DIMM✕1)
Additional Memory - 128MB (128MB SDRAM-DIMM✕1) GP5-RM12F Additional Memory - 256MB (256MB SDRAM-DIMM✕1) GP5-RM25F Additional Memory - 512MB (512MB SDRAM-DIMM✕1) GP5-RM51F
Internal Hard Disk (1)Disk Addition / Duplexing
e
Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) (Max.8) GP5-HDH46
❋Up to 8 disks in a teamserver
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) (Max.8) GP5-HDH95
BAY 1~6 : 4.5GB / 9.1GB / 18.2GB BAY 7~8 : 4.5GB / 9.1GB
Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) (Max.8) GP5-HDH81 (2)Internal Disk Array
y
y
RAID Card (Cache : 16MB) GP5U141
Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) (Max.8) GP5-HDH46
RAID Card (Cache : 4MB, Internal use only) GP5U142
Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) (Max.8) GP5-HDH95
RAID Card (Cache : 32MB, Ultra2 Wide SCSI) GP5-144
Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) (Max.8) GP5-HDH81
Server Monitor Module GP5USM102
Others Redundant Power Supply Unit GP5UPU131
i
NOTE : 2 PSUs are required as standard if any of the following are installed. 2CPUs or 5+HDDs or 3+PCIs Maximum 3PSUs can be instaled in G800i series.
15
System Configuration teamserver C800i series tearserver C800i series CPU : Pentium®III (500MHz) / Pentium®II (450MHz / 400MHz / 350MHz)✕1(~2) , Cache (L1+L2) : 32KB+512KB, Internal Hard disk bay : 4slots (Hot plug : 3slots) , CD-ROM, On board LAN, On board SCSI, Intel LANDesk®Server Manger GP5C870 GP5C850 GP5C821 GP5C810 [Pedestal type]
[1CPU / Pedestal Type] (April / 99) 1CPU(Pentium®III 500MHz), Memory : 64MB (ECC) , HDD : Option [1CPU / Pedestal Type] 1CPU(Pentium®II 450MHz), Memory : 64MB (ECC) , HDD : Option [1CPU / Pedestal Type] 1CPU(Pentium®II 400MHz), Memory : 64MB (ECC) , HDD : Option [1CPU / Pedestal Type] 1CPU(Pentium®II 350MHz), Memory : 64MB (ECC) , HDD : Option
GP5C870R GP5C850R [Rackmount type]
GP5C821R GP5C810R
[1CPU / Rackmount Type] (April / 99) 1CPU(Pentium®III 500MHz), Memory : 64MB (ECC) , HDD : Option [1CPU / Rackmount Type] 1CPU(Pentium®II 450MHz), Memory : 64MB (ECC) , HDD : Option [1CPU / Rackmount Type] 1CPU(Pentium®II 400MHz), Memory : 64MB (ECC) , HDD : Option [1CPU / Rackmount Type] 1CPU(Pentium®II 350MHz), Memory : 64MB (ECC) , HDD : Option
CPU ®
q ®
®
®
Memory
w
CPU Field Upgrade Kit (Pentium®II-500MHz (512KB) ✕1) GP5-FG10N (for C870i) CPU Field Upgrade Kit (Pentium®II-450MHz (512KB) ✕1) GP5-FG10G (for C850i) CPU Field Upgrade Kit (Pentium®II-400MHz (512KB) ✕1) GP5-FG10C (for C820i) CPU Field Upgrade Kit (Pentium®II-350MHz (512KB) ✕1) GP5-FG10B (for C810i)
Max : 1GB Additional Memory - 64MB (64MB SDRAM-DIMM✕1) GP5-RM64F
Standard memory : 64MB (64MB SDRAM-DIMM✕1)
Additional Memory - 128MB (128MB SDRAM-DIMM✕1) GP5-RM12F Additional Memory - 256MB (256MB SDRAM-DIMM✕1) GP5-RM25F
Internal Hard Disk
Total 4 disks(3Hot Plug and 1non-Hot Plug) can be installed.
(1)Disk Addition to Hot Plug bays (Max . 3 disks)
Hard Disk Drive - 4GB (Ultra Wide.7,200rpm) (Hot Plug) GP5-HDH44
e
Hard Disk Drive - 9GB (Ultra Wide.7,200rpm) (Hot Plug) GP5-HDH92
Hard Disk Drive - 4GB (Ultra Wide.7,200rpm) (Hot Plug) GP5-HDH44
(2)Internal Disk Array(Maximum 3Hot Plug disks can be installed)
y
RAID Card (Cache : 16MB) GP5U141
RAID Card (Cache : 4MB Internal Hard disk only) GP5U142
GP5-831 SCSI Cable (Intl.)
Hard Disk Drive - 9GB (Ultra Wide.7,200rpm) (Hot Plug) GP5-HDH92
RAID Card (Cache : 8MB Internal Hard disk only) GP5-143
GP5U142 and GP5-143 cannot be used in the same platform.
y
Server Monitor Module GP5USM102 (Feb.1999)
(3)Disk Addition to a non-Hot Plug bay
only one disk can be installed
e
Hard Disk Drive-4GB (7,200rpm) (non-Hot Plug) GP5-HD4G5
Hard Disk Drive - 9GB (7,200rpm) (non-Hot Plug) GP5-HD9G2
16
System Configuration teamserver C300i series termserver C300i series CPU : Pentium®II (400MHz)✕1, Cache (L1+L2) : 32KB+512KB, Internal Hard disk bay : 4slots , CD-ROM, On board LAN, Intel LANDesk®Server Manger(std.) GP5C320 [1CPU/Pedestal Type] 1CPU Pentium®II(400MHz) , Memory : 64MB(ECC SDRAM), HDD:Option CPU : Pentium®II (350MHz)✕1 , Cache (L1+L2) : 32KB+512KB, Internal Hard disk bay : 4slots, (1slot:5inch bay) CD-ROM, On board LAN, Intel LANDisk® Server Manager(std.) GP5C310
[1CPU / Pedestal Type] 1CPU Pentium®II (350MHz), Memory : 64MB (ECC SDRAM) , HDD : Option
CPU:Celeron (300AMHz)✕1 , Cache (L1+L2) : 32KB+128KB, Internal Hard disk bay : 4slots, CD-ROM, ON board LAN, Intel LANDisk® Server Manager(std.) GP5C300
[1CPU / Pedestal Type] 1CPU(Celeron 300AMHz), Memory : 64MB (ECC SDRAM) , HDD : Option
Memory
w
Max : 768MB Additional Memory-32MB (32MB SDRAM-DIMM ✕1) GP5-RM32H
Standard memory : 64MB-DIMM✕1
Additional Memory-64MB (64MB SDRAM-DIMM ✕1) GP5-RM64H
Additional Memory-128MB (128MB SDRAM-DIMM ✕1) GP5-RM12H Additional Memory-256MB (256MB SDRAM-DIMM ✕1) GP5-RM25H
Internal Hard Disk
Max : 4disks
(1)Disk Addition Max : 2
(EIDE Disk)
Hard Disk Drive-4GB (EIDE) (5400rpm) GP5-HD4E1
e
Hard Disk Drive-8GB (EIDE) (5400rpm) GP5-HD8E1
(SCSI Disk)
Max : 4
y SCSI Card GP5-125
SCSI Cable GP5-837
Hard Disk Drive-4GB (Ultra Wide. 7200rpm) (non-Hot plug) GP5-HD4G5
Hard Disk Drive-9GB (Ultra Wide. 7200rpm) (non-Hot plug) GP5-HD9G2
(2) Internal Disk Array Hard Disk Drive-4GB (Ultra Wide. 7200rpm) (non-Hot plug) GP5-HD4G5
y RAID Card (Cache : 16MB) GP5U141
SCSI Cable GP5-837
Hard Disk Drive-9GB (Ultra Wide. 7200rpm) (non-Hot plug) GP5-HD9G2
RAID Card (Cache : 4MB, For internal HDD only) GP5U142
RAID Card (Cache : 8MB, For internal HDD only) GP5-143
GP5U142 and GP5-143 cannot be used in the same platform.
y
Server Monitor Module GP5USM102 (Feb.1999)
17
System Configuration teamserver Internal Devices M800i
G800i
L800i
C800i
series
series
C300i series
SCSI Card GP5-125
y y
y
SCSI Card GP5-125
y
SCSI Card GP5U121
Internal Cable (Wide SCSI) to connect GP5-DL351 is attached to DLT unit
Internal Cable (Wide SCSI) to connect GP5-ML301 is attached to Tape unit
DLT unit (35GB) GP5-DL351 ❋Two 5 inch bays occupied
Tape unit (MLR3) GP5-ML301
Only G800i
Only C800i
r
DLT unit (20GB) GP5UDL201 ❋Two 5 inch bays occupied
r Only G800i
r
DAT unit (intl.) (DDS3) GP5UDT301 ❋Only one GP5UDT301 can be installed in the lowest 5 inch bay in teamserver C800i and G800i.
r y
SCSI Card GP5-125
SCSI Cable GP5-838
Tape unit (SLR5) GP5USL501
Tape unit (NS20) GP5-NS201
18
System Configuration
teamserver External Devices M800i
G800i
L800i
C800i
C300i series
(Pedestal only)
Maximaum 2 Hard Disk Cabinets can be connected to a server
series series
Hard Disk Cabinet-Single End
(Please refer to page 20 for Rackmount configuration.)
<(1)In case of Maximum 7 Hard Disk Units installed> Non-Disk Array
y
y y
SCSI Card GP5-125
Only G800i
y
Only C800i
y
Disk Array
y
y
SCSI Cable GP5MU823A
SCSI Card GP5U121 SCSI Cable GP5MU829A
RAID Card GP5U141
<(2)In case of Maximum 14 Hard Disk Units installed> Non-Disk Array
y
y y
SCSI Cable GP5MU823A X2
SCSI Card GP5-125 X 2
Only G800i
y Disk Array
y
Hard Disk Cabinet-Single End GP5MS621A Please refer below for inside configuration
Hard Disk Cabinet-Single End GP5MS621A Please refer below for inside configuration
SCSI Card GP5U121 X 2
Only C800i
y
Hard Disk Cabinet-Single End GP5MS621A Please refer below for inside configuration
y
SCSI Cable GP5MU829A X2
RAID Card GP5U141
Hard Disk Cabinet-Single End GP5MS621A Please refer below for inside configuration
NOTE : The maximum 28 disks (2 Hard Disk Cabinets) can be connected to a server via one RAID Card (GP5U141). The maximum 14 disks (1 Hard Disk Cabinet) can be connected to a server via one SCSI Card.
[Configuration of the inside of Hard Disk Cabinet-Single End] <(1)Maximum 7 Hard Disk Units installed> <(2)Maximum 14 Hard Disk Units installed> Hard Disk Drive-4GB (7,200rpm) GP5MHDH4GA
Hard Disk Drive-4GB (7,200rpm) GP5MHDH4GA
Hard Disk Drive-9GB (7,200rpm) GP5MHDH9GA
Hard Disk Drive-9GB (7,200rpm) GP5MHDH9GA
Power Supply Unit Rackmount GP5MPU101A
Power Supply Unit Rackmount GP5MPU101A
NOTE : Maximum 7 Hard Disk Units can be installed (Maximum 6 Hard Disk Units can be installed when a PSU is installed.)
Additional Shelf GP5MS621SA
Hard Disk Drive-4GB (7,200rpm) GP5MHDH4GA Hard Disk Drive-9GB (7,200rpm) GP5MHDH9GA Power Supply Unit Rackmount GP5MPU101A
NOTE : Maximum 7 Hard Disk Units can be installed (Maximum 6 Hard Disk Units can be installed when a PSU is installed.)
19
System Configuration
teamserver Rackmount
40U Rack GP5-R1RC2
40U Rack & Rack Coupling kit GP5-R1RC3
❋A maximum of two servers can be installed in a Rack system.
❋The Rack Coupling kit is used for connecting two Racks together.
Component Shelf GP5-R1TB4
teamserver CPU nodes for Rackmount
Keyboard/Monitor Extention Cables GP5-411
Key board/Monitor Enhanced Switch GP5-SB101
Enhanced keyboard GP5-R1KB2
M800i / L800i / G800i
y
SCSI Card GP5-125
SCSI Cable GP5MU823A
SCSI Card GP5U121
SCSI Cable GP5MU823A
RAID Card GP5U141
SCSI Cable GP5MU830A
C800i
Keyboard/Monitor Shelf Kit GP5-R1TB3 Storage System GP5UR1DC2 ❋The number of these cabinets depends on the configuration.
M800i / L800i / G800i
y
SCSI Card GP5-126
SCSI Cable GP5MU823A
RAID Card GP5-144
SCSI Cable GP5S-832
[Inside of Storage System]
Hard Disk Drive-4GB(7,200rpm) GP5-HDH45
Hard Disk Drive-9GB(7,200rpm) GP5-HDH93
Hard Disk Drive-9GB(10,000rpm) GP5-HDH94
Hard Disk Drive-18GB(7,200rpm) GP5-HDH81
Hard Disk Drive-18GB(10,000rpm) GP5-HDH82 Redundant Power Supply Unit GP5UR1PU1
NOTE : A maximum of eight Hard Disk Drives can be installed in a Storage System. In a RAID configuration, a physical pack must be comprised by the same type of hand disks.
20
Storage System(Ultra2 Wide) GP5UR1DC3 ❋The number of this cabinet depends on the configuration.
System Configuration Network Cards teamserver
M800i
G800i
L800i
C800i
C300i series
series series
y
y
LAN Card GP5-183
y
y y
LAN Card GP5-182
teamserver Cluster System Configuration (U.S. only) Cluster System using Microsoft® Windows NT Server , Enterprise Edition V4.0 teamserver M800i/L800i/G800i
y
SCSI Card GP5-123
SCSI Cable (Procured locally)
y teamserver M800i / L800i / G800i
LVS Disk Array (U.S. only)
y y
SCSI Cable (Procured locally)
SCSI Card GP5-123
21
teamserver Hardware Folowing models (Pentium II Xeon 450MHz models) are Available from Feb.1999 Product teamserverM861i
Product ID GP5M861LR
Remarks Pentium II Xeon 450MHz with 2MB Cache (x2, up to 8CPUs) , 512MB EDO-DIMM with ECC,50ns ( 16GB maximum )
(Rackmount)
PCI64bitx10,PCI32bitx11,ISA/PCI32bitx1 , 24xCD-ROM,FDD,Fast narrow SCSI controller is on board
(June 1999)
12Internal HDD bays (Ultra2wide SCSI/Hot plug) - 76bays maximum : Intl. HDD(12)+GP5UR1DC3x8 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM * Windows NT4.0 supports up to 4CPUs and 4GB Memory, more than that supported by Windows NT 4.0E.E
teamserverM851i
GP5M851LR
Pentium II Xeon 450MHz with 1MB Cache (x2, up to 8CPUs) , 512MB EDO-DIMM with ECC,50ns ( 16GB maximum )
(Rackmount)
PCI64bitx10,PCI32bitx11,ISA/PCI32bitx1 , 24xCD-ROM,FDD,Fast narrow SCSI controller is on board
(June 1999)
12Internal HDD bays (Ultra2wide SCSI/Hot plug) - 76bays maximum : Intl. HDD(12)+GP5UR1DC3x8 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM * Windows NT4.0 supports up to 4CPUs and 4GB Memory, more than that supported by Windows NT 4.0E.E
teamserverM860i
GP5M860L
Pentium II Xeon 450MHz with 2MB Cache (x1, up to 8CPUs) , 256MB EDO-DIMM with ECC, 50ns (8GB maximum) PCI64bitx5,PCI32bitx5,ISA/PCI32bitx1,24xCD-ROM,FDD,Fast narrow SCSI controller is on board 6Internal HDD bays (Ultra2wide SCSI/Hot plug) - 14bays maximum : Intl. HDD(6)+GP5UR1DC3 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM * Windows NT4.0 supports up to 4CPUs and 4GB Memory, more than that supported by Windows NT 4.0E.E
teamserverM860i
GP5M860LR
(Rackmount)
Pentium II Xeon 450MHz with 2MB Cache (x1, up to 8CPUs) , 256MB EDO-DIMM with ECC,50ns ( 8GB maximum ) PCI64bitx5,PCI32bitx5,ISA/PCI32bitx1,24xCD-ROM,FDD,Fast narrow SCSI controller is on board 6Internal HDD bays (Ultra2wide SCSI/Hot plug) - 76bays maximum : Intl. HDD(12)+GP5UR1DC3x8 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM * Windows NT4.0 supports up to 4CPUs and 4GB Memory, more than that supported by Windows NT 4.0E.E
teamserverM850i
GP5M850
(June 1999)
Pentium II Xeon 450MHz with 1MB Cache (x1, up to 8CPUs) , 256MB EDO-DIMM with ECC,50ns ( 8GB maximum ) PCI64bitx5,PCI32bitx5,ISA/PCI32bitx1,24xCD-ROM,FDD,Fast narrow SCSI controller is on board 6Internal HDD bays (Ultra2wide SCSI/Hot plug) - 14bays maximum : Intl. HDD(6)+GP5UR1DC3 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM * Windows NT4.0 supports up to 4CPUs and 4GB Memory, more than that supported by Windows NT 4.0E.E
teamserverM850i
GP5M850LR
Pentium II Xeon 450MHz with 1MB Cache (x1, up to 8CPUs) , 256MB EDO-DIMM with ECC,50ns ( 8GB maximum )
(Rackmount)
PCI64bitx5,PCI32bitx5,ISA/PCI32bitx1,24xCD-ROM,FDD,Fast narrow SCSI controller is on board
(June 1999)
6Internal HDD bays (Ultra2wide SCSI/Hot plug) - 76bays maximum : Intl. HDD(12)+GP5UR1DC3x8 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM * Windows NT4.0 supports up to 4CPUs and 4GB Memory, more than that supported by Windows NT 4.0E.E
teamserverM850ic
GP5M850AL
Pentium II Xeon 450MHz with 1MB Cache (x1, up to 4CPUs) , 256MB EDO-DIMM with ECC,50ns ( 8GB maximum ) PCI64bitx5,PCI32bitx5,ISA/PCI32bitx1,24xCD-ROM,FDD,Fast narrow SCSI controller is on board 6Internal HDD bays (Ultra2wide SCSI/Hot plug) - 14bays maximum : Intl.HDD(6)+GP5UR1DC3 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM * Windows NT4.0 supports up to 4CPUs and 4GB Memory, more than that supported by Windows NT 4.0E.E
teamserverM850ic (Rackmount)
GP5M850BL
Pentium II Xeon 450MHz with 1MB Cache (x1, up to 4CPUs) , 256MB EDO-DIMM with ECC,50ns ( 8GB maximum ) PCI64bitx5,PCI32bitx5,ISA/PCI32bitx1,24xCD-ROM,FDD,Fast narrow SCSI controller is on board 6Internal HDD bays (Ultra2wide SCSI/Hot plug) - 62 bays maximum : Intl. HDD(6)x1 +GP5UR1DC3x7 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM * Windows NT4.0 supports up to 4CPUs and 4GB Memory, more than that supported by Windows NT 4.0E.E
22
teamserver Hardware Product teamserverM840i
Product ID GP5M840L
(Feb.1999)
Remarks Pentium II Xeon 450MHz with 512KB Cache (x1, up to 4CPUs) , 256MB EDO-DIMM with ECC,50ns ( 8GB maximum ) PCI64bitx5,PCI32bitx5,ISA/PCI32bitx1,24xCD-ROM,FDD,Fast narrow SCSI controller is on board 6Internal HDD bays (Ultra2wide SCSI/Hot plug) - 14bays maximum : Intl.HDD(6)+GP5UR1DC3 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM * Windows NT4.0 supports up to 4CPUs and 4GB Memory, more than that supported by Windows NT 4.0E.E
teamserverM840i
GP5M840LR
(Rackmount)
Pentium II Xeon 450MHz with 512KB Cache (x1, up to 4CPUs) , 256MB EDO-DIMM with ECC,50ns ( 8GB maximum ) PCI64bitx5,PCI32bitx5,ISA/PCI32bitx1,24xCD-ROM,FDD,Fast narrow SCSI controller is on board 6Internal HDD bays (Ultra2wide SCSI/Hot plug) - 62 bays maximum : Intl. HDD(6)x1 +GP5UR1DC3x7 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM * Windows NT4.0 supports up to 4CPUs and 4GB Memory, more than that supported by Windows NT 4.0E.E
teamserverL850i
GP5L850L
Pentium II Xeon 450MHz with 1MB Cache (x1, up to 4CPUs) , 128MB EDO-DIMM with ECC,50ns ( 4GB maximum ) PCIx6ISA/PCIx1,24xCD-ROM,FDD,2xUltra2wide&1x Fast narrow SCSI is on board 8Internal HDD bays (Ultra2Wide SCSI/Hot plug) 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM,Wakeup On LAN
teamserverL850i
GP5L850LR
(Rackmount)
Pentium II Xeon 450MHz with 1MB Cache (x1, up to 4CPUs) , 128MB EDO-DIMM with ECC,50ns ( 4GB maximum ) PCIx6ISA/PCIx1,24xCD-ROM,FDD,2xUltra2wide&1x Fast narrow SCSI is on board 8Internal HDD bays (Ultra2Wide SCSI/Hot plug) - 40bays maximum : Intl. HDD(8)+GP5UR1DC3x4 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM,Wakeup On LAN
teamserverL840i
GP5L840L
Pentium II Xeon 450MHz with 512KB Cache (x1, up to 4CPUs) , 128MB EDO-DIMM with ECC,50ns ( 4GB maximum ) PCIx6ISA/PCIx1,24xCD-ROM,FDD,2xUltra2wide&1x Fast narrow SCSI is on board 8Internal HDD bays (Ultra2Wide SCSI/Hot plug) - 40bays maximum : Intl. HDD(8)+GP5UR1DC3x4 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM,Wakeup On LAN
teamserverL840i (Rackmount)
GP5L840R
Pentium II Xeon 450MHz with 512KB Cache (x1, up to 4CPUs) , 128MB EDO-DIMM with ECC,50ns ( 4GB maximum ) PCIx6ISA/PCIx1,24xCD-ROM,FDD,2xUltra2wide&1x Fast narrow SCSI is on board 8Internal HDD bays (Ultra2Wide SCSI/Hot plug) - 40bays maximum : Intl. HDD(8)+GP5UR1DC3x4 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM,Wakeup On LAN
23
teamserver Hardware Product
teamserverG870i
Product ID
GP5G870L
Remarks
Pentium III 500MHz with 512KB Cache (x1, up to 2CPUs) , 64MB SDRAM (Single DIMM with ECC,2GB maximum ) PCIx4Shared (ISA/PCI)x1ISAx1,32xCD-ROM,FDD,2xUltra2wide&1x Fast narrow SCSI is on board 8Internal HDD bays (Ultra2Wide SCSI/Hot plug) 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM,Wakeup On LAN
teamserverG870i
GP5G870LR
Pentium III 500MHz with 512KB Cache (x1, up to 2CPUs) , 64MB SDRAM (Single DIMM with ECC,2GB maximum ) PCIx4Shared (ISA/PCI)x1ISAx1,32xCD-ROM,FDD,2xUltra2wide&1x Fast narrow SCSI is on board
(Rackmount)
8Internal HDD bays (Ultra2Wide SCSI/Hot plug) - 40bays maximum : Intl. HDD(8)+GP5UR1DC3x4 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM,Wakeup On LAN
teamserverG850i
GP5G850L
Pentium II 450MHz with 512KB Cache (x1, up to 2CPUs) , 64MB SDRAM (Single DIMM with ECC,2GB maximum ) PCIx4Shared (ISA/PCI)x1ISAx1,32xCD-ROM,FDD,2xUltra2wide&1x Fast narrow SCSI is on board 8Internal HDD bays (Ultra2Wide SCSI/Hot plug) 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM,Wakeup On LAN
teamserverG850i
GP5G850LR
(Rackmount)
Pentium II 450MHz with 512KB Cache (x1, up to 2CPUs) , 64MB SDRAM (Single DIMM with ECC,2GB maximum ) PCIx4Shared (ISA/PCI)x1ISAx1,32xCD-ROM,FDD,2xUltra2wide&1x Fast narrow SCSI is on board 8Internal HDD bays (Ultra2Wide SCSI/Hot plug) - 40bays maximum : Intl. HDD(8)+GP5UR1DC3x4 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM,Wakeup On LAN
teamserverG820i
GP5G820L
Pentium II 400MHz with 512KB Cache (x1, up to 2CPUs) , 64MB SDRAM (Single DIMM with ECC,2GB maximum ) PCIx4Shared (ISA/PCI)x1ISAx1,32xCD-ROM,FDD,2xUltra2wide&1x Fast narrow SCSI is on board 8Internal HDD bays (Ultra2Wide SCSI/Hot plug) 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM,Wakeup On LAN
teamserverG820i
GP5G820LR
(Rackmount)
Pentium II 400MHz with 512KB Cache (x1, up to 2CPUs) , 64MB SDRAM (Single DIMM with ECC,2GB maximum ) PCIx4Shared (ISA/PCI)x1ISAx1,32xCD-ROM,FDD,2xUltra2wide&1x Fast narrow SCSI is on board 8Internal HDD bays (Ultra2Wide SCSI/Hot plug) - 40bays maximum : Intl. HDD(8)+GP5UR1DC3x4 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM,Wakeup On LAN
teamserverC870i
GP5C870
Pentium II 500MHz with 512KB Cache (x1, up to 2CPUs) , 64MB SDRAM (Single DIMM with ECC,1GB maximum ) PCIx3,ISAx2,32xCD-ROM,FDD,1xUltrawide&1xFast narrow SCSI is on board 4Internal HDD bays (Ultra Wide SCSI/3xHot plug) - 32bays maximum : Intl. HDD(4)+(GP5MS621A+GP5MS621SA)x2 100Base-TX/10Base-T,LDSM,Wakeup On LAN
teamserverC870i
GP5C870R
(Rackmount)
Pentium III 500MHz with 512KB Cache (x1, up to 2CPUs) , 64MB SDRAM (Single DIMM with ECC,1GB maximum ) PCIx3,ISAx2,32xCD-ROM,FDD,1xUltrawide&1xFast narrow SCSI is on board 4Internal HDD bays (Ultra Wide SCSI/3xHot plug) - 36bays maximum : Intl. HDD(4)+GP5UR1DC2x4 100Base-TX/10Base-T,LDSM,Wakeup On LAN
teamserverC850i
GP5C850
Pentium II 450MHz with 512KB Cache (x1, up to 2CPUs) , 64MB SDRAM (Single DIMM with ECC,1GB maximum ) PCIx3,ISAx2,32xCD-ROM,FDD,1xUltrawide&1xFast narrow SCSI is on board 4Internal HDD bays (Ultra Wide SCSI/3xHot plug) - 32bays maximum : Intl. HDD(4)+(GP5MS621A+GP5MS621SA)x2 100Base-TX/10Base-T,LDSM,Wakeup On LAN
teamserverC850i (Rackmount)
GP5C850R
Pentium II 450MHz with 512KB Cache (x1, up to 2CPUs) , 64MB SDRAM (Single DIMM with ECC,1GB maximum ) PCIx3,ISAx2,32xCD-ROM,FDD,1xUltrawide&1xFast narrow SCSI is on board 4Internal HDD bays (Ultra Wide SCSI/3xHot plug) - 36bays maximum : Intl. HDD(4)+GP5UR1DC2x4 100Base-TX/10Base-T,LDSM,Wakeup On LAN
24
teamserver Hardware Product teamserverC820i
Product ID GP5C821
Remarks Pentium II 400MHz with 512KB Cache (x1, up to 2CPUs) , 64MB SDRAM (Single DIMM with ECC,1GB maximum ) PCIx3,ISAx2,32xCD-ROM,FDD,1xUltrawide&1xFast narrow SCSI is on board 4Internal HDD bays (Ultra Wide SCSI/3xHot plug) - 32bays maximum : Intl. HDD(4)+(GP5MS621A+GP5MS621SA)x2 100Base-TX/10Base-T,LDSM,Wakeup On LAN
teamserverC820i
GP5C821R
(Rackmount)
Pentium II 400MHz with 512KB Cache (x1, up to 2CPUs) , 64MB SDRAM (Single DIMM with ECC,1GB maximum ) PCIx3,ISAx2,32xCD-ROM,FDD,1xUltrawide&1xFast narrow SCSI is on board 4Internal HDD bays (Ultra Wide SCSI/3xHot plug) - 36bays maximum : Intl. HDD(4)+GP5UR1DC2x4 100Base-TX/10Base-T,LDSM,Wakeup On LAN
teamserverC810i
GP5C810
Pentium II 350MHz with 512KB Cache (x1, up to 2CPUs) , 64MB SDRAM (Single DIMM with ECC,1GB maximum ) PCIx3,ISAx2,32xCD-ROM,FDD,1xUltrawide&1xFast narrow SCSI is on board 4Internal HDD bays (Ultra Wide SCSI/3xHot plug) - 32bays maximum : Intl. HDD(4)+(GP5MS621A+GP5MS621SA)x2 100Base-TX/10Base-T,LDSM,Wakeup On LAN
teamserverC810i
GP5C810R
(Rackmount)
Pentium II 350MHz with 512KB Cache (x1, up to 2CPUs) , 64MB SDRAM (Single DIMM with ECC,1GB maximum ) PCIx3,ISAx2,32xCD-ROM,FDD,1xUltrawide&1xFast narrow SCSI is on board 4Internal HDD bays (Ultra Wide SCSI/3xHot plug) - 36bays maximum : Intl. HDD(4)+GP5UR1DC2x4 100Base-TX/10Base-T,LDSM,Wakeup On LAN
teamserver C320i
GP5C320
Pentium II 400MHz with 512KB Cache (x1),64MB Unbuffered SDRAM (Single DIMM with ECC,768MB maximum) PCIx4,ISAx1, 3x3.5''/1x5'' HDD bays (Ultrawide SCSI /EIDE, non-Hot plug) - 32bays maximum : Intl. HDD(4)+(GP5MS621A+GP5MS621AS)x2 32xCD-ROM,FDD, 100Base-TX/10Base-T,LDSM,Wakeup On LAN
teamserver C310i
GP5C310
Pentium II 350MHz with 512KB Cache (x1),64MB Unbuffered SDRAM (Single DIMM with ECC,768MB maximum) PCIx4,ISAx1, 3x3.5''/1x5'' HDD bays (Ultrawide SCSI /EIDE, non-Hot plug) - 32bays maximum : Intl. HDD(4)+(GP5MS621A+GP5MS621SA)x2 32xCD-ROM,FDD, 100Base-TX/10Base-T,LDSM,Wakeup On LAN
teamserver C300i
GP5C300
Celeron 300AMHz with 128KB Cache (x1),64MB Unbuffered SDRAM (Single DIMM with ECC,768MB maximum) PCIx4,ISAx1, 3x3.5''/1x5'' HDD bays (Ultrawide SCSI /EIDE, non-Hot plug) - 32bays maximum : Intl. HDD(4)+(GP5MS621A+GP5MS621SA)x2 32xCD-ROM,FDD, 100Base-TX/10Base-T,LDSM,Wakeup On LAN
25
teamserver Hardware
CPU Field Upgrade Kit
C300i
C310i
C320i
C810i
C820i
C850i
C870i
G820i
G850i
L840i
G870i
L850i
M840i
M850i
M850ic
M860i
Produt ID
M851i
Product
M861i
Models
GP5-FG10M ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Remarks
P-II Xeon(450MHz)/32KB+2MBcachex1,Placed on motherboard Include one CPU and dedicated power supply module(VRM)
CPU Field Upgrade Kit
GP5-FG10K
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
P-II Xeon(450MHz)/32KB+1MBcachex1,Placed on motherboard Include one CPU and dedicated power supply module(VRM)
CPU Field Upgrade Kit
GP5-FG10H
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
P-II Xeon(450MHz)/32KB+512KBcachex1,Placed on motherboard Include one CPU and dedicated power supply module(VRM)
CPU Field Upgrade Kit
GP5-FG10F
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
P-II Xeon(400MHz)/32KB+1MBcachex1,Placed on motherboard Include one CPU and dedicated power supply module(VRM)
CPU Field Upgrade Kit
GP5-FG10D
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
PIIXeon(400MHz)/32KB+512KBx1, Placed on motherboard Include one CPU and dedicated power supply module(VRM)
CPU Cabinet Upgrade Kit
GP5U78C1UL ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
(June 1999) CPU Cabinet Upgrade Kit
and one CPU(P-II Xeon 400MHz/1MB LVD) GP5U85L1
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
(June 1999) CPU Cabinet Upgrade Kit
Upgrade Option 4way to 8way, Only for M850i Slave node,MCU Cardx2, fibre Cable and one CPU(P-II Xeon 450MHz/1MB)
GP5U86L2
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
(June 1999) CPU Field Upgrade Kit
Upgrade Option 4way to 8way, Only for M830i Slave node,MCU Cardx2, fibre Cable
Upgrade Option 4way to 8way, Only for M860i Slave node,MCU Cardx2, fibre Cable and one CPU(P-II Xeon 450MHz/2MB)
GP5-FG10N
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
PIII(500MHz)/32KB+512KB, for G870i/C870i G870i:Placed on CPU memory board, C870i:Placed on motherboard Only use with processors of same size and type
CPU Field Upgrade Kit
GP5-FG10G ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
PII(450MHz)/32KB+512KB, for G850i/C850i G850i:Placed on CPU memory board, C850i:Placed on motherboard Only use with processors of same size and type
CPU Field Upgrade Kit
GP5-FG10C
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
PII(400MHz)/32KB+512KBx1, for G820i/C820i C820i:Placed on CPU memory board, C820i:Placed on motherboard Only use with processors of same size and type
CPU Field Upgrade Kit
GP5-FG10B
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
PII(350MHz)/32KB+512KBx1, for G810i/C810i G810i:Placed on CPU memory board, C810i:Placed on motherboard Only use with processors of same size and type
Additional Memory 1GB
GP5-RM1G
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
EDO-DIMM(Buffered;50ns)256MBx4
Additional Memory 512MB
GP5-RM51G ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
EDO-DIMM(Buffered;50ns)128MBx4
Additional Memory 256MB
GP5-RM25G ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
EDO-DIMM(Buffered;50ns)64MBx4
Additional Memory 128MB
GP5-RM12G ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
EDO-DIMM(Buffered;50ns)32MBx4
Additional Memory 512MB
GP5-RM51F ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
SDRAM-DIMM 512MBx1 (Registered 100MHz)
Additional Memory 256MB
GP5-RM25F ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
SDRAM-DIMM 256MBx1 (Registered 100MHz)
Additional Memory 128MB
GP5-RM12F ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
SDRAM-DIMM 128MBx1 (Registered 100MHz)
Additional Memory 64MB
GP5-RM64F ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
SDRAM-DIMM 64MBx1 (Registered 100MHz)
Additional Memory 256MB
GP5-RM25H ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Unbuffered SDRAM-DIMM 256MBx1
Additional Memory 128MB
GP5-RM12H ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Unbuffered SDRAM-DIMM 128MBx1
(Mar.1999)
Additional Memory 64MB GP5-RM64H ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Unbuffered SDRAM-DIMM 64MBx1
Additional Memory 32MB GP5-RM32H ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Unbuffered SDRAM-DIMM 32MBx1
HDD-18GB
GP5-HDH82 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
18.2GB,Ultra2wide SCSI,10000rpm,SCA2 80pin,Hotplug for M8xxi,L8xxi,also Storage System(GP5UR1DC2/3)
HDD-9GB
GP5-HDH94 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
9.1GB,Ultra2wide SCSI,10000rpm,SCA2 80pin,Hotplug for M8xxi,L8xxi,also Storage System(GP5UR1DC2/3)
26
teamserver Hardware
HDD-18GB
C300i
C310i
C320i
C810i
C820i
C850i
C870i
G820i
G850i
L840i
G870i
L850i
M840i
M850i
M850ic
M860i
Produt ID
M851i
Product
M861i
Models
GP5-HDH81 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Remarks
18.2GB,Ultra2wide SCSI,7200rpm,SCA2 80pin,Hotplug for M8xxi,L8xxi,also Storage System(GP5UR1DC2/3)
HDD-9GB
GP5-HDH93 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
9.1GB,Ultra2wide SCSI,7200rpm,SCA2 80pin,Hotplug for M8xxi,L8xxi,also Storage System(GP5UR1DC2/3)
HDD-4GB
GP5-HDH45 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
4.5GB,Ultra2wide SCSI,7200rpm,SCA2 80pin,Hotplug for M8xxi,L8xxi,also Storage System(GP5UR1DC2/3)
HDD-9GB
GP5-HDH95 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
9.1GB,Ultra2wide SCSI,7200rpm,SCA2 80pin,Hotplug for G8xxi
HDD-4GB
GP5-HDH46 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
4.3GB,Ultra2wide SCSI,7200rpm,SCA2 80pin,Hotplug for G8xxi
HDD-9GB
GP5-HDH92 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
9.1GB,Ultrawide SCSI,7200rpm,SCA2 80pin,Hotplug for C8xxi
HDD-4GB
GP5-HDH44 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
4.3GB,Ultrawide SCSI,7200rpm,SCA2 80pin,Hotplug for C8xxi
HDD-9GB
GP5-HD9G2 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
9.1GB,Ultrawide SCSI,7200rpm,68pin, Non Hotplug for C8xxi(Mounted in Non Hotplug bay),C3xxi
HDD-4GB
GP5-HD4G5 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
4.3GB,Ultrawide SCSI,7200rpm,68pin, Non Hotplug for C8xxi(Mounted in Non Hotplug bay),C3xxi
HDD-8GB(EIDE)
GP5-HD8E1
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
EIDE,5400rpm, 8.4GB, for C320i/310i/300i
HDD-4GB(EIDE)
GP5-HD4E1
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
EIDE,5400rpm, 4.3GB, for C320i/310i/300i
HDD-9GB
GP5MHDH9GA - - - - - - - - - - - - - - - - - -
9.1GB,Ultrawide SCSI,7200rpm, Hotplug Only for Hard Disk Cabinet(GP5MS621S,GP5MS621SA)
HDD-4GB
GP5MHDH4GA - - - - - - - - - - - - - - - - - -
4.3GB,Ultrawide SCSI,7200rpm, Hotplug Only for Hard Disk Cabinet(GP5MS621S,GP5MS621SA)
DAT unit (DDS-3)
GP5UDT301 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
DDS-3 (12-24GB) *The backup utility can be used with the NTBACKUP for Windows NT4.0 and ARC serve for Windows NT6.0.(Windows NT3.51 is not supported), The ARC serve for Windows NT6.0.needs Service Pack 3 or greater. Media is not included. Only one can be mounted in the lowest 5''bay (G8xxi/C8xxi),SCSI2
Tape unit (SLR5)
GP5USL501 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
SLR5 (4-8GB) Backup utilities: NTBACKUP,SBACKUP,ARCserve for Windows NT4.0,ARCserve for Netware 6.5 Media is not supplied. SCSI2
DLT unit
GP5UDL201 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
DLT4000SE Narrow (20-40GB) Required S/W :ARCserve for Windows NT6.0 or greater (Windows NT4.0),, ARCserve Storage Suite 6.5 or greater(BackOffice small BusinessServer 4.0) *NTBACKUP,SBACKUP can not be used as a backup device. Two bays required and occupied. Cleaning cartridgex1/Data cartridgex1 is attached. SCSI2
DLT unit
GP5-DL351
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
DLT7000SE Wide (35-70GB) Required S/W :ARCserve for Windows NT6.0 or greater (Windows NT4.0), ARCserve Storage Suite 6.5 or greater(BackOffice small BusinessServer 4.0) *NTBACKUP,SBACKUP can not be used as a backup device. Two bays required and occupied. SCSI Adapter(GP5-125)is required to connect. Cleaning cartridgex1/Data cartridgex1/Internal SCSI cable(with terminal register)is attached.
Tape unit (MLR3)
GP5-ML301
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
MLR3 (25-50GB) The backup utility can be used with NTBACKUP, ARCserve for WindowsNT J6.5 L20(Windows NT4.0), NTBACKUP, ARCserve Storage. SCSI Adapter(GP5U121/GP5-125)is required to connect.
TRAVAN NS unit(NS20)
GP5-NS201
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
TRAVAN NS20 (10-20GB) The backup utility can be used with NTBACKUP, ARCserve for WindowsNT J6.5 L20(Windows NT4.0), NTBACKUP, ARCserve Storage Suite J6.5
Redundant Power Supply Unit GP5UPU131 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
27
Redundant PSU (450W)
teamserver Hardware
C300i
C310i
C320i
C810i
C820i
C850i
C870i
G820i
G850i
L840i
G870i
L850i
M840i
M850i
M850ic
M860i
Produt ID
M851i
Product
M861i
Models
Redundant Power Supply Unit GP5UPU141 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■ ■ R/P R/P R/P R/P R R R R R R R R R R R R
Redundant Power Supply Unit
GP5UR1PU1
Power Supply Unit
GP5MPU101A P P P P P P P P P P P P P P P P P P
Rackmount Pattern BR
GP5R8K1
R R R R R R R R R R R R R R R R R R
Remarks
Redundant PSU (350W) Redundant PSU for Storage System (GP5UR1DC2/GP5UR1DC3), (365W) Redundant PSU for HD Cabinet (GP5MS621A), (180W) Basic/Additional Rack Pattern K-1 for C/G/L8xxi
Rackmount Pattern BR
GP5R8K2
R R R R R R R R R R R R R R R R R R
Basic/Additional Rack Pattern K-2 for C/G/L8xxi
Rackmount Pattern BR
GP5R8K3
R R R R R R R R R R R R R R R R R R
Basic/Additional Rack Pattern K-3 for C/G/L8xxi
Rackmount Pattern BR
GP5R8K4
R R R R R R R R R R R R R R R R R R
Basic/Additional Rack Pattern K-4 for C/G/L8xxi
Rackmount Pattern BR
GP5R8K5
R R R R R R R R R R R R R R R R R R
Basic/Additional Rack Pattern K-5 for C/G/L8xxi
Rackmount Pattern BR
GP5R8K6
R R R R R R R R R R R R R R R R R R
Basic/Additional Rack Pattern K-6 for C/G/L8xxi
Rackmount Pattern BR
GP5R8K7
R R R R R R R R R R R R R R R R R R
Basic/Additional Rack Pattern K-7 for C/G/L8xxi
Rackmount Pattern BR
GP5R8K8
R R R R R R R R R R R R R R R R R R
Basic/Additional Rack Pattern K-8 for C/G/L8xxi
Rackmount Pattern BR
GP5M8K1
■ ■ R R R R R R ■ R R R R R R R R R
Basic/Additional Rack Pattern K-1 for M8xxi
Rackmount Pattern BR
GP5M8K2
■ ■ R R R R R R ■ R R R R R R R R R
Basic/Additional Rack Pattern K-2 for M8xxi
Rackmount Pattern BR
GP5M8K3
■ ■ R R R R R R ■ R R R R R R R R R
Basic/Additional Rack Pattern K-3 for M8xxi
Rackmount Pattern BR
GP5M8K4
■ ■ R R R R R R ■ R R R R R R R R R
Basic/Additional Rack Pattern K-4 for M8xxi
Rackmount Pattern BR
GP5M8K5
■ ■ R R R R R R ■ R R R R R R R R R
Basic/Additional Rack Pattern K-5 for M8xxi
Rackmount Pattern BR
GP5M8K6
■ ■ R R R R R R ■ R R R R R R R R R
Basic/Additional Rack Pattern K-6 for M8xxi
Rackmount Pattern AR
GP5AR8K1
■ ■ R R R R R R R R R R R R R R R R
Additional Rack Pattern Z-1 for C/G/L/M8xxi
Rackmount Pattern AR
GP5AR8K2
■ ■ R R R R R R R R R R R R R R R R
Additional Rack Pattern Z-2 for C/G/L/M8xxi
Rackmount Pattern AR
GP5AR8K3
■ ■ R R R R R R R R R R R R R R R R
Additional Rack Pattern Z-3 for C/G/L/M8xxi
Rackmount Pattern AR
GP5AR8K4
■ ■ R R R R R R R R R R R R R R R R
Additional Rack Pattern Z-4 for C/G/L/M8xxi
Rackmount Pattern AR
GP5AR8K5
■ ■ R R R R R R R R R R R R R R R R
Additional Rack Pattern Z-5 for C/G/L/M8xxi
Rackmount Pattern AR
GP5AR8K6
■ ■ R R R R R R R R R R R R R R R R
Additional Rack Pattern Z-6 for C/G/L/M8xxi
40U Rack
GP5-R1RC2 ■ ■ R R R R R R R R R R R R R R R R
19'' 40U Locker , Front door,rear door,side panel,earthquake proof board , blank panel is attached. Size(WxDxH)mm:600x900x2035 C8xxi:6U, G8xxi:7U, L8xxi:7U, M840/850/860/850ic:10U, M851i/861i:20U GP5UR1DC2/GP5UR1DC3:4U UPS(1400VA):3U, UPS(3000VA):5U Keyboard/Monitor Shelf:9U(for installation 15''CRT), 2U(for installation Keyboard) Component shelf:4U CRT/KB switch:Mounted at side of CRT(occupies same U as CRT)
40U Rack&Rack Coupling Kit
GP5-R1RC3 ■ ■ R R R R R R R R R R R R R R R R
19''40U Locker + connection metal fittings Front door,rear door,concatenation frame,blank panel is attached. Size(WxDxH)mm:600x900x2035 Units can be installed as for GP5-R1RC2
Component Shelf
GP5-R1TB4
■ ■ R R R R R R R R R R R R R R R R
28
Shelf to fit peripheral device into 40U Rack, Table size:400x500
teamserver Hardware
Keyboard/Monitor Shelf Kit
GP5-R1TB3
C300i
C310i
C320i
C810i
C820i
C850i
C870i
G820i
G850i
L840i
G870i
L850i
M840i
M850i
M850ic
M860i
Produt ID
M851i
Product
M861i
Models
■ ■ R R R R R R R R R R R R R R R R
Remarks
CRT/KB shelf for Rackmountable type *Only a 15''CRT can be installed on the CRT storage table.
Keyboard/Monitor Enhanced Switch GP5-SB101
■ ■ R R R R R R R R R R R R R R R R
Switch enables sharing of a set of CRT,keyboard,and mouse by two or more servers (up to four servers). CRT/KB cable, CRT cable, KB/mouse cable is prepared separately.
Keyboard/Monitor Extension Cables
GP5-411
■ ■ R R R R R R R R R R R R R R R R
CRT/KB cable , (CRT cablex1,KB cablex1 is attached)
Enhanced Keyboard
GP5-R1KB2
■ ■ R R R R R R R R R R R R R R R R
87Key keyboard for Rackmountable type
Storage System (Ultrawide SCSI)
GP5UR1DC2 ■ ■ R R R R R R R R R R R R R R R R
8Hard Disk Drive Bays(Hotplugable) Redundant HD/FAN(Two as a standard eqipment)/PSU(A GP5UR1PU1 is a standard equipment, up to two) GP5-HDH45/HDH93/HDH81/ HDH94/HDH82 can be mounted. Ultrawide SCSI
Storage System (Ultra2wide SCSI) GP5UR1DC3 ■ ■ R R R R R R R R R R R R R R R R
8Hard Disk Drive Bays(Hotplugable) Redundant HD/FAN(Two as a standard eqipment)/PSU(A GP5UR1PU1 is a standard equipment, up to two) GP5-HDH45/HDH93/HDH81/ HDH94/HDH82 can be mounted. Ultra2wide SCSI
Hard Disk Cabinet (Single End)
GP5MS621A P P P P P P P P P P P P P P P P P P
7Hard Disk Dirve Bays(Hotplugable) 14Bays is maximum (GP5MS621SA is used) Redundant HD/FAN(Up to two)/PSU(GP5MSPU101A is standard equipment, up to two) GP5MHDH4GA/9GA can be mounted. Ultrawide SCSI
Additional Shelf SCSI Card
GP5MS621SA P P P P P P P P P P P P P P P P P P GP5U121
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Additional shelf only for GP5MS621A, Same as the basic shelf Ultrawide, SE, x1ch, SMART not supported, Up to 40MB/s of syncronous transfer support, Connector: half-pitch 68pin for external SCSI device, half-pitch 50/68pin for internal SCSI device. To connect with GP5MS621A, GP5UR1DC2 or external SCSI devices *SCSI cable is required
SCSI Card
GP5-123
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Ultrawide, differential-end, x1ch, SMART not supported, Up to 40MB/s of syncronous transfer support, Connector:half-pitch 68pin for external SCSI device, half-pitch 50/68pin for internal SCSI device For connection with Disk Array devices *SCSI cable is required
SCSI Card
GP5-125
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Ultrawide, SE, x1ch, SMART supported, Up to 40MB/s of syncronous transfer support, Connector:half-pitch 68pin for external SCSI device, half-pitch 50/68pin for internal SCSI device. For connection with internal and external SCSI devices *SCSI cable is required
SCSI Card
GP5-126
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Ultra2wide, LVD, x1ch, SMART supported, Up to 80MB/s of syncronous transfer support, Connector:half-pitch 68pin for external SCSI divece, half-pitch 50/68pin for internal SCSI device. For connection with internal and external SCSI devices *SCSI cable is required
RAID Card
GP5U141
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
RAID card, Ultrawide SCSI, SE, x2ch, 16MB cache, RAID level 0,1,5 are supported, For internal/external array configuration *SCSI cable(for array configuration use)is reauired
RAID Card
GP5U142
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
RAID card, Ultrawide SCSI, SE, x2ch, 4MB cache, RAID level 0,1,5 are supported, For internal array configuration *SCSI cable(for array configuration use)is required
RAID Card
GP5-143
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
RAID card, Ultrawide SCSI, x2ch, 8MB cache, RAID level 0,1,5 are supported, For internal array configuration *SCSI cable(for array configuration use) is required
RAID Card
GP5-144
RAID card, Ultra2wide SCSI, LVD, x3ch, 32MB cache, RAID level 0,1,5 are
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
supported, For internal/external array configuration *SCSI cable(for array configuration use) is required
SCSI Cable
GP5U831
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Connection internal devices (0.7m) for C8xxi
SCSI Cable
GP5S-832
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
For connection GP5-144 to GP5UR1DC3
SCSI Cable
GP5-837
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Internal SCSI HDD connection(68pin) for C3xxi
SCSI Cable
GP5-838
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Internal narrow SCSI cable for 5'' Bay (50pin) for C3xxi
SCSI Cable
GP5MU823A ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
SCSI-3(68pin)-SCSI-4(68pin), For connecting GP5U121/125 to GP5MS621A, GP5UR1DC2 / GP5-126 to GP5UR1DC3(3.0m)
SCSI Cable
GP5MU829A - - - - - - - - - - - - - - - - - -
For connection between GP5U141 and GP5MS621A (2.0m)
SCSI Cable
GP5MU830A - - - - - - - - - - - - - - - - - -
For connection GP5U141 to GP5MS621A /GP5U141 to GP5UR1DC2 (3.0m) A cable is required in 1ch
29
teamserver Hardware
SCSI Cable
C300i
C310i
C320i
C810i
C820i
C850i
C870i
G820i
G850i
L840i
G870i
L850i
M840i
M850i
M850ic
M860i
Produt ID
M851i
Product
M861i
Models
GP5MU831A - - - - - - - - - - - - - - - - - -
Remarks
SCSI-4(68pin)-SCSI-4(68pin) ,For connecting each Hard Disk Cabinet (GP5MS621A), (0.3m)
SCSI Cable
GP5U832
- - - - - - - - - - - - - - - - - -
For connection between SCSI Card and external SCSI device (full pitch-50pin),(1.0m)
SCSI Cable
GP5U833
- - - - - - - - - - - - - - - - - -
For connection between SCSI Card and external SCSI device (half pitch50pin),(1.0m)
SCSI Cable
GP5U834
- - - - - - - - - - - - - - - - - -
For connection between SCSI Card and external SCSI device (half pitch68pin),(1.5m)
LAN Card
GP5-182
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
100BASE-TX/10BASE-T, PCI-bus, driver is included Twisted pair cable (category 5:100BASE-TX/category3:10BASE-T) is required
LAN Card
GP5-183
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
GIGA bit LAN Card supports 1000BASE-SX optical fiber cables, compatible with both 64-bit and 32-bit PCI slots.Driver is included, a Fibre channel Cable (GP5311:2m, GP5-312:5m, GP5-313:15m) is required.
Server Monitor Module
GP5USM102 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
SMM has its own CPU,LAN,and power supply(AC adapter, option). External Interface:10BASE-T RJ45/RS232C D-sub 9pin, AC adapter:16V(DC) *Modem-only operation is impossible
30
MEMO
31
Specifications are subject to change without notice. For the latest detailed information, contact your local representative. All brand names and product names are trademarks and registered trademarks of their respective holders. C1999 Fujitsu Limited. All rights reserved. Printed in Japan. Third Edition February 1999
FUJITSU LIMITED Business Development & Marketing Division Marketing Group Marunouchi Center Building 6-1, Marunouchi 1-chome, Chiyoda-ku, Tokyo 100-8211, Japan Phone: +81-3-3215-5255 Fax: +81-3-3215-5259 URL http://www.fujitsu.co.jp/index-e.html
BK0065-3NS 32