Preview only show first 10 pages with watermark. For full document please download

Server98/ ł\1.2

   EMBED


Share

Transcript

System Configuration Guide (V.3) (Feb / 1999) - Notes ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P2 teamserver M851i/861i------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P7 teamserver M850i/860i------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P8 teamserver M850ic ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P10 teamserver M840i ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P12 teamserver L800i series --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P14 teamserver G800i series--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P15 teamserver C800i series --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P16 teamserver C300i series --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P17 teamserver Internal Devices ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P18 teamserver External Devices --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P19 teamserver Rackmount ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P20 teamserver Network Cards-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P21 teamserver Cluster System configuration(U.S.only) ---------------------------------------------------------------------------------------------------------------------------------------------------P21 Hardware ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------P22 Index Key to The numbers on the left hand side of each page correspond to the various options available with teamservers as follows : CPU slot RAM module slot 3.5 inch HDD Bay 5 inch Bay RS-232C PCI slot ISA slot Redundant PSU Others Or 1 And NOTES This System Configuration Guide (V.3) introduces new PentiumIII 500MHz models, G870i and C870i and withdraws all old models. The shipment of G870i and C870i commences at End/March and End/April respectively. Please refer to http://www.fujitsu.co.jp/hypertext/InfoPro/mspl/teamserver/config.html for old models. Upgrade 4way to 8way (June 1999) Upgrade kit is required to expand CPU nodes on M850i/860i ■ CPU Cabinet Upgrade Kit *Available from June 1999 When upgrading from 4way pedestal system to 8way, rackmounting is required. To connect additional internal Storage (M800i) SCSI Card or RAID Card is required to connect hard disks. Onboard SCSI can be used to connect to SCSI devices in 5inch bays. A SCSI Card (GP5-125) is required to mount DLT(GP5-DL351),Tape unit(GP5-ML301). Storage System (GP5UR1DC2,GP5UR1DC3) is required when more than 7HDDs are installed. 14HDDs in total can be mounted in a Pedestal. A SCSI Card (GP5-126) is required to connect up to four HDDs in an Ultra2 wide Storage System (GP5URIDC3) Therefore, two sets of SCSI Card and Cable are required to connect more than five HDDs in a Storage System. How to mount internal HDDs (L800i/G800i) 18.2GB HDD cannot be mounted in bay #7 and #8. However 4.3GB / 4.5GB / 9.1GB HDD can be mounted in all bays. Restriction of Operating System (M800i) Windows NT Server 4.0 supports up to 4CPUs and 4GB of memory. Windows NT Server 4.0 Enterprise Edition is required for more than 4 CPUs and 4GB of Memory. Mounting additional memory (M851i/861i) Memory expansion must be performed in bank units by mounting four similar capacity DIMMs in one bank. Memory expansion must be performed by mounting bank units in ascending order of memory capacity alternatively on Master and Slave node. (M840i/850ic/850i/860i) Memory must be expanded in bank units by mounting four similar capacity DIMMs in one bank. Memory is expanded in bank units by mounting DIMMs in ascending order of memory capacity alternately on two RAM base cards. (L800i) Mount the same capacity DIMM's in units of four. (Mounting of DIMM's with different capacities or a set of less than four DIMM's is not allowed) Mount the DIMM's in ascending order of their capacity. Use DIMM slots in the order from bank A (J1 to J4) to bank B (J5 to J8), bank C (J9 to J12), and bank D (J13 to J16) (G800i/C800i,C300i) The mother board has four slots for RAM modules (including standard equipment), Please install RAM modules in the order of the slot number. (teamserver C3xxi has three slots) 2 NOTES S.M.A.R.T. function S.M.A.R.T. function is available in the combinations below: ■ : Corresponds , x:Does not correspond , -:N/A Internal Hard disk units IDE Models Hard disk cabinet SCSI Hard disks GP5UR1DC2 GP5UR1DC3 GP5MS621A Standard Standard SCSI card RAID card SCSI card RAID card SCSI card RAID card SCSI/RAID card equipment equipment GP5-125 GP5-126 GP5-144 GP5U141 GP5-143 GP5U142 GP5U121 GP5-125 GP5U141 GP5-126 GP5-144 GP5U121/-125/U141 IDE SCSI C300i ■ - x - - x ■ x - ■ x - - x C800i - ■ - - - x ■ x x - x - - x G800i - ■ - - ■ x - x - ■ x ■ ■ x L800i - ■ - - ■ x - - - ■ x ■ ■ x M800i - - - ■ ■ x - - - ■ x ■ ■ x M831/851/861i - - - ■ ■ x - - - ■ x ■ ■ - Additional bus-slots The number of bus-slots which can be used depends on each model. models Number of standard bus-slots Product ID REMARKS M8x1i PCI(64bit)x10 PCI(32bit)x11 PCI/ISA(32bit)x1 GP5M851LR GP5M861LR LAN card is mounted in a PCI(32bit)slot. M800i / M800ic PCI(64bit)x5 PCI(32bit)x5 PCI/ISA(32bit)xl GP5M850L GP5M860L GP5M850AL GP5M840L GP5M850LR GP5M860LR GP5M850BL GP5M840LR LAN card is mounted in a PCI(32bit)slot. L800i PCIx6 PCI/ISAx1 GP5L820L GP5L830L GP5L840L GP5L850L GP5L820LR GP5L830LR GP5L840LR GP5L850LR LAN card is mounted in a PCI(32bit)slot. G800i PCIx4 PCI/ISAx1 ISAx1 GP5G820L GP5G850L GP5G870L GP5G820LR GP5G850LR GP5G870LR All of the slots are available C800i PCIx3 ISAx2 GP5C810 GP5C821 GP5C850 GP5C870 GP5C810R GP5C821R GP5C850R GP5C870R All of the slots are available C300i PCIx4 ISAx1 GP5C300 GP5C310 GP5C320 All of the slots are available 3 NOTES Number of mountable optional cards M831i/851i/861i Cards Product ID RAID card GP5U141 (Ultrawide SE) RAID card (Ultra2wide LVD) M820i/830ic/830i/840i/850ic/850i/860i Bus Maximum number of cards mounted Total PCI64 6 10 REMARKS Bus Maximum number of cards mounted Total RAID card GP5U141 (Ultrawide SE) PCI64 4 5 RAID card GP5-144 (Ultra2wide LVD) PCI64 5 Cards GP5U141 and GP5-144 cannot be used in the same platform Product ID GP5U141 and GP5-144 cannot be used in the same platform GP5-144 PCI64 6 SCSI card GP5-125 (Ultrawide SE) PCI64 9 SCSI card (Ultrawide SE) GP5-125 PCI64 4 SCSI card (Ultra2wide LVD) PCI64 10 SCSI card (Ultra2wide LVD) GP5-126 PCI64 5 2 SCSI card (Ultrawide Diff) PCI64 2 Fibre Channel GP5-FC101 card PCI64 2 LAN card GP5-183 PCI64 1 LAN card GP5-182 PCI32 3 LAN card Standard equipment PCI32 1 Server Monitor Module GP5USM102 PCI32 1 1 Product ID Bus Maximum number of cards mounted Total SCSI card (Ultrawide Diff) GP5-123 PCI 2 SCSI card (Ultrawide SE) GP5-125 PCI 3 SCSI card (Ultrawide Diff) GP5-126 GP5-123 PCI64 Fibre Channel GP5-FC101 card PCI64 2 LAN card GP5-183 PCI64 1 LAN card GP5-182 PCI32 3 LAN card Standard equipment PCI32 1 Server Monitor Module GP5USM102 For external disk array 2 4 Mounted in PCI slot3(fixed) PCI32 1 Bus Maximum number of cards mounted 1 L800i Product ID SCSI card (Ultrawide Diff) GP5-123 SCSI card (Ultra2wide LVD) For external disk array 2 4 Mounted in PCI slot3(fixed) G800i Cards SCSI card (Ultrawide SE) GP5-123 REMARKS GP5-125 PCI 2 Total 3 3 PCI 3 PCI RAID card GP5U141 (Ultrawide SE) PCI 2 RAID card (Ultra2wide LVD) PCI 3 GP5-144 Cards For external disk array 7* GP5-126 REMARKS Fibre Channel GP5-FC101 card PCI 2 LAN card GP5-183 PCI 1 LAN card GP5-182 PCI 3 Use for internal/external SCSI devices GP5U141 and GP5-144 cannot be used in the same platform Mounted only in PCI-A2 For external disk array Use for internal/external SCSI devices 3 SCSI card GP5-126 (Ultra2wide LVD) PCI 3 RAID card (Ultrawide SE) GP5U141 PCI 2 RAID card (Ultrawide) GP5U142 5 PCI 1 RAID card GP5-144 (Ultra2wide LVD) PCI 3 Fibre Channel GP5-FC101 card PCI 2 REMARKS Internal/external array cofiguration Only for internal array configuration GP5-144 cannot be used with other RAID card in the seme platform LAN card GP5-183 PCI 1 LAN card GP5-182 PCI 3 SMM GP5USM102 PCI 1 Product ID Bus Maximum number of cards mounted RAID card GP5U141 (Ultrawide SE) PCI 2 RAID card GP5U142 (Ultrawide SE) PCI 1 RAID card (Ultrawide SE) GP5-143 Only for internal array configuration (Cannot be used with GP5-143) PCI 1 Only for internal array configuration (Cannot be used with GP5U142) GP5-125 PCI 3 Use for internal/external SCSI devices GP5-182 PCI 3 3 GP5USM102 PCI 1 1 4 LAN card Standard equipment PCI 1 SMM GP5USM102 PCI 1 Mounted in PCI-A1(fixed) Mounted only in PCI-A3 * Up to six cards can be mounted when an ISA card is used. C800i C300i Product ID Bus Maximum number of cards mounted RAID card (Ultrawide SE) GP5U141 PCI 2 RAID card (Ultrawide SE) GP5U142 PCI 1 Cards RAID card (Ultrawide SE) SCSI card LAN card LAN card SMM Total REMARKS Internal/external array configuration 2 1 3 Only for internal array configuration (Cannot be used with GP5-143) GP5-143 PCI 1 Only for internal array configuration (Cannot be used with GP5U142) GP5U121 PCI 2 Only for external SCSI devices GP5-183 PCI 1 GP5-182 PCI 3 GP5USM102 PCI 1 Cards SCSI card LAN card SMM 4 Total 3 REMARKS Internal/external array configuration NOTES Disk array configuration • Physical pack • Logical drive • Partition • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• A collection of physical HDDs comprising a RAID System. Logical drive (ex. D: ) seen by the Operating System. One of the logical access units into which a logical drive is divided. Physical pack HDD HDD HDD HDD Logical drive A Logical drive B Partition 1 * Drives can be divided into partition. Partition 2 Logical drive C (1) Physical pack must be comprised of the same type of HDDs. (2) Maximum logical drive size is 2TB (GP5U141/142). (3) The number of HDDs comprising a physical pack is as shown below. RAID Level Discription RAID 0 ) The data is broken down into blocks,each on a RAID 1 ) Duplicates the disk and writes the same data RAID 5 ) separate disk drive onto two disks. HDDs Capacity of logical drives ( 2~8 The capacity of logical drive is same as the ( 2 The capacity of the logical drive is half the 3~8 The capacity of each logical drive is the number The data is broken down into blocks and each blocks is written together with parity bits on a separate disk drive. ( capacity of connected HDD. capacity of connected HDD. (4) The same RAID level must be used when dividing a physical pack into a number of logical drives. (5) A physical pack must comprise only of HDDs which are connected by the same RAID card. (6) A RAID card can support more than one physical pack. ( even if different RAID levels) (7) Internal and external array devices cannot be connected to the same RAID card. (except for M8xx ~) 5 of connected HDDs - 1. NOTES Hard disk cabinet/RAID card/SCSI card ●Hard disk cabinet GP5MS621A: Up to two can be connected Operating System has to be installed on an internal hard disk. ●RAID card (GP5U141/GP5-144) Up to two Hard disk cabinets can be connected with one RAID card. Internal disks and Hard disk cabinets (in array configuration) cannot be connected to the same RAID card. ●RAID card (GP5U142/GP5-143) Only for use with internal devices. Only one RAID card can be used per a server. ●SCSI card (GP5U121/GP5-125/GP5-126) Internal and external devices cannot be connected to the same SCSI card. Maximum number of daisy chain connection allowed : (1) Up to four external devices (but not Hard disk cabinets) can be connected by daisy chain. (2)Only one Hard disk cabinet can be connected. (Daisy chain connection is not available) 6 System Configuration teamserver M851i/861i (June 1999) CPU : Pentium®II Xeon™ (450MHz) ✕2 (~8) , Cache (L1+L2) : 32KB+1MB/2MB, Internal Hard disk bay : 12slots (Hot plug), CD-ROM , LAN Card (std.), Intel LANDesk®Server Manager, Redundant power supply (option), Redundant Fan (std.) , 19inch Rack (Display, Keyboard, Hard Disk Cabinet and UPS have to be purchased separately) GP5M851LR [2CPU / Rackmount Type] 2CPU(Cache:1MB) , Memory : 512MB (ECC) , HDD : Option GP5M861LR [2CPU / Rackmount Type] 2CPU(Cache:2MB) , Memory : 512MB (ECC) , HDD : Option teamserver M851i / M861i Configuration teamserver M851i / M861i consists of a master node and a slave node. CPU Master Node Slave Node Std. Max. Std. Max. 1 4 1 4 Memory 256MB (64MB✕4) 8GB (256MB✕32) 256MB (64MB✕4) 8GB (256MB✕32) 3.5 inch HDD 5 inch Bay 109.2GB (18.2GB✕6bays) 109.2GB (18.2GB✕6bays) 1 (CD-ROM) 4 4 PCI (32bit) 1 (LAN Card) 5 6 Expansion slots PCI (64bit) ISA / PCI (32bit) 5 1 5 0 Power Supply Unit 2 3 2 3 NOTE : - The addition of Hard disks requires a SCSI Card. - Hard disk duplexing requires two SCSI Cards. CPU CPU Field Upgrade Kit Pentium®II Xeon 450MHz (2MB) ✕1 GP5-FG1OM (for M861i) q CPU Field Upgrade Kit Pentium®II Xeon 450MHz (1MB) ✕1 GP5-FG1OK(for M851i) Memory Max : 16GB Additional Memory -256MB (64MB-DIMM✕4) GP5-RM25G w Standard memory : 512MB (64MB-DIMM✕4✕2sets) Additional Memory - 512MB (128MB-DIMM✕4) GP5-RM51G Additional Memory - 1024MB (256MB-DIMM✕4) GP5-RM1G Hard Disk Drive (1)Disk Addition / Duplexing (Up to 12 disks in a teamserver) y Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45 SCSI Card (Ultra2 Wide.) GP5-126 Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82 (2)Internal Disk Array y RAID Card (Cache : 16MB) GP5U141 Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45 y RAID Card (Cache : 32MB, Ultra2 . Wide SCSI) GP5-144 Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 y Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 Server Monitor Module GP5USM102 Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82 Others i Redundant Power Supply Unit GP5UPU141 7 System Configuration teamserver M850i / 860i (Feb.1999) teamserver M860i / 850i CPU : Pentium®II Xeon™ (450MHz) ✕1 (~4, max : 8) , Cache (L1+L2) : 32KB+1MB/2MB , Internal Hard disk bay : (Hot plug) 14slots (Pedestal) / 6slots (Rackmount) , CD-ROM , LAN Card (std.) , Intel LANDesk®Server Manager , Redundant Power Supply (Option), Redundant Fan (std.) GP5M850L GP5M860L [1CPU / Pedestal Type] 1CPU, (Cache:1MB), Memory : 256MB (ECC) , HDD : Option [1CPU / Pedestal Type] 1CPU, (Cache:2MB), Memory : 256MB (ECC) , HDD : Option [Pedestal type] GP5M850LR GP5M860LR [1CPU / Rackmount Type] 1CPU (Cache:1MB), Memory : 256MB (ECC) , HDD : Option [1CPU / Rackmount Type] 1CPU (Cache:2MB), Memory : 256MB (ECC) , HDD : Option [Rackmount type] 8way Upgrade CPU Cabinet Upgrade Kit GP5U86L2(for 2 MB cache) ❋When you upgrade to 8 way, rackmounting is required. Please consult your sales representative. (June 1999) o CPU Cabinet Upgrade Kit GP5U85L1(for 1 MB cache) ❋When you upgrade to 8 way, rackmounting is required. Please consult your sales representative. (June 1999) CPU CPU Field Upgrade Kit Pentium®II Xeon™-450MHz (2MB) ✕1 GP5-FG10M (for M860i) q CPU Field Upgrade Kit Pentium®II Xeon™-450MHz (1MB) ✕1 GP5-FG10K (for M850i) Memory Max. memory: 8GB Additional Memory - 256MB (64MB-DIMM✕4) GP5-RM25G w Standard memory : 256MB (64MB-DIMM✕4) Additional Memory - 512MB (128MB-DIMM✕4) GP5-RM51G Internal Hard Disk ❋Pedestal Type : Up to 14 (6 in standard, 8 in optional Storage System) disks can be installed. Rackmount Type : Up to 6 disks can be installed in a rackmount type node. Additional Memory - 1024MB (256MB-DIMM✕4) GP5-RM1G (1)Disk Addition / Duplexing y Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45 SCSI (Ultra2 Wide) GP5-126 Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82 Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45 y SCSI Card (Ultra2 Wide) GP5-126 SCSI Cable GP5MU823A Storage System GP5UR1DC3 ❋It can be inserted into M860/850i Pedestal Type. Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 SCSI Card (Ultra2 Wide) GP5-126 SCSI Cable GP5MU823A Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 Secand set of a SCSI Card and a Cable is required to mount disks in 5th-8th HDD bays in a Storage System. Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82 NOTE : Hard disk duplexing requires two SCSI Cards and a Storage System. Redundant Power Supply Unit GP5UR1PU1 ❋Please refer to P.20 for the connection of Storage System in Rackmount model. 8 System Configuration (2)Internal Disk Array Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45 y RAID Card (Cache : 16MB) GP5U141 Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82 Redundant Power Supply Unit GP5UR1PU1 Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45 SCSI Cable GP5MU830A Storage System GP5UR1DC2 ❋It can be inserted into M860/850i Pedestal model. Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82 Redundant Power Supply Unit GP5UR1PU1 Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45 y RAID Card (Cache : 32MB Ultra2 Wide SCSI) GP5-144 Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82 Redundant Power Supply Unit GP5UR1PU1 Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45 SCSI Cable GP5S-832 Storage System GP5UR1DC3 ❋It can be inserted into M860/850i Pedestal model. Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 y Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82 Server Monitor Module GP5USM102 Redundant Power Supply Unit GP5UR1PU1 Others i Redundant Power Supply Unit GP5UPU141 9 System Configuration teamserver M850ic (Feb.1999) teamserver M850ic CPU : Pentium®II Xeon™ (450MHz) ✕1(~4), Cache (L1+L2) : 32KB+1MB , Internal Hard disk bay : (Hot plug) 14slots (Pedestal) / 6slots (Rackmount) , CD-ROM , LAN Card (std.) , Intel LANDesk®Server Manager , Redundant Power Supply (Option), Redundant Fan (std.) GP5M850AL [1CPU / Pedestal Type] 1CPU, Memory : 256MB (ECC) , HDD : Option [Pedestal type] GP5M850BL [1CPU / Rackmount Type] 1CPU, Memory : 256MB (ECC) , HDD : Option [Rackmount type] CPU CPU Field Upgrade Kit (Pentium®II Xeon™-450MHz (1MB) ✕1) GP5-FG10K q Memory w Max. memory: 8GB Additional Memory - 256MB (64MB-DIMM✕4) GP5-RM25G Standard memory : 256MB (64MB-DIMM✕4) Additional Memory - 512MB (128MB-DIMM✕4) GP5-RM51G Additional Memory - 1024MB (256MB-DIMM✕4) GP5-RM1G Internal Hard Disk ❋Pedestal Type : Up to 14 (6 in standard, 8 in optional Storage System) disks can be installed. Rackmount Type : Up to 6 disks can be installed in a rackmount type node. (1)Disk Addition / Duplexing y Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45 SCSI Card (Ultra2 Wide) GP5-126 Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82 Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45 y SCSI Card (Ultra2 Wide) GP5-126 SCSI Card (Ultra2 Wide) GP5-126 SCSI Cable GP5MU823A Storage System GP5UR1DC3 ❋It can be inserted into M850ic Pedestal Type. SCSI Cable GP5MU823A Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82 Secand set of a SCSI Card and a Cable is required to mount disks in 5th-8th HDD bays in a Storage System. Redundant Power Supply Unit GP5UR1PU1 NOTE : Hard disk duplexing requires two SCSI Cards and a Storage System ❋Please refer to P.20 for the connection of Storage System in Rackmount model. 10 System Configuration (2)Internal Disk Array Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45 y RAID Card (Cache : 16MB) GP5U141 Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82 Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45 SCSI Cable GP5MU830A Storage System GP5UR1DC2 ❋It can be inserted into M850ic Pedestal model. Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82 Redundant Power Supply Unit GP5UR1PU1 Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45 y RAID Card (Cache : 32MB Ultra2 Wide SCSI) GP5-144 Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82 Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45 SCSI Cable GP5S-832 Storage System GP5UR1DC3 ❋It can be inserted into M850ic Pedestal model. Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 y Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82 Server Monitor Module GP5USM102 Redundant Power Supply Unit GP5UR1PU1 Others i Redundant Power Supply Unit GP5UPU141 11 System Configuration teamserver M840i (Feb.1999) teamserver M840i CPU : Pentium®II Xeon™ (450MHz) ✕1 / 2 (~4) , Cache (L1+L2) : 32KB+512KB, Internal Hard disk bay : (Hot plug) 14slots (Pedestal) / 6slots (Rackmount) ,CD-ROM , LAN Card (std.) , Intel LANDesk®Server Manager, Redundant Power Supply (Option) , Redundant Fan(std.) GP5M840L [1CPU / Pedestal Type] 1CPU, Memory : 256MB (ECC) , HDD : Option [Pedestal type] GP5M840LR [1CPU / Rackmount Type] 1CPU, Memory : 256MB (ECC) , HDD : Option [Rackmount type] CPU CPU Field Upgrade Kit-450MHz (512KB) ✕1 GP5-FG10H q Memory w Max : 8GB Additional Memory- 256MB (64MB-DIMM✕4) GP5-RM25G Standard memory : 256MB (64MB-DIMM✕4) Additional Memory - 512MB (128MB-DIMM✕4) GP5-RM51G AdditionalMemory- 1024MB (256MB-DIMM✕4) GP5-RM1G Internal Hard Disk ❋Pedestal Type : Up to 14 (6 in standard, 8 in optional Disk node) disks can be installed. Rackmount Type : Up to 6 disks can be installed in a rackmount type node. (1)Disk Addition / Duplexing Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45 y SCSI Card (Ultra2 Wide) GP5-126 Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82 Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45 y SCSI Card (Ultra2 Wide) GP5-126 SCSI Card (Ultra2 Wide) GP5-126 SCSI Cable GP5MU823A Storage System GP5UR1DC3 ❋It can be inserted into M840i Pedestal Type. SCSI Cable GP5MU823A Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 Tow sets of SCSI cards and cables are required to mount 5th-8th HDDs in Storage System. Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82 Redundant Power Supply Unit GP5UR1PU1 12 System Configuration (2)Internal Disk Array y Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45 RAID Card (Cache : 16MB) GP5U141 Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82 Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45 SCSI Cable GP5MU830A Storage System GP5UR1DC2 ❋It can be inserted into M840i Pedestal model. Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82 Redundant Power Supply Unit GP5UR1PU1 Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45 y RAID Card (Cache : 32MB Ultra2 Wide SCSI) GP5-144 Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82 Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45 SCSI Cable GP5S-832 Storage System GP5UR1DC3 ❋It can be inserted into M840i Pedestal model. Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 y Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82 Server Monitor Module GP5USM102 Redundant Power Supply Unit GP5UR1PU1 Others i Redundant Power Supply Unit GP5UPU141 NOTE ; Please reter to P.20 for rackmounting instructions. 13 System Configuration teamserver L800i series (Feb.1999) teamserver L800series CPU : Pentium®II Xeon™ (450MHz) ✕1 (~4) , Cache (L1+L2) : 32KB+512KB / 1MB , Internal Hard disk bay : 8slots (Hot plug) , CD-ROM, LAN Card (std.) On board SCSI, Intel LANdesk®Server Manager(std.) GP5L840L GP5L850L [Pedestal type] [1CPU / Pedestal Type] 1CPU(Cache : 512KB), Memory : 128MB (ECC) , HDD : Option [1CPU / Pedestal Type] 1CPU(Cache : 1MB), Memory : 128MB (ECC) , HDD : Option GP5L840LR GP5L850LR [1CPU / Rackmount Type] 1CPU(Cache : 512KB), Memory : 128MB (ECC) , HDD : Option [1CPU / Rackmount Type] 1CPU(Cache : 1MB), Memory : 128MB (ECC) , HDD : Option [Rackmount type] CPU CPU Field Upgrade Kit - 450MHz(1MB)✕1 GP5-FG10K (for L850i) q CPU Field Upgrade Kit - 450MHz(512KB)✕1 GP5-FG10H (for L840i) Memory w Max : 4GB Additional Memory - 128MB (32MB-DIMM✕4) GP5-RM12G Standard memory : 128MB (32MB-DIMM✕4) Additional Memory - 256MB (64MB-DIMM✕4) GP5-RM25G Additional Memory - 512MB (128MB-DIMM✕4) GP5-RM51G Additional Memory - 1024MB (256MB-DIMM✕4) GP5-RM1G Internal Hard Disk (1)Disk Addition / Duplexing Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45 e ❋Up to 8 disks can be installed Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 Bay 1~6 : 4.5GB/9.1GB/18.2GB Bay 7~8 : 4.5GB/9.1GB Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82 Internal Disk Array y Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH45 RAID Card (Cache : 16MB) GP5U141 y Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH93 RAID Card (Cache : 32MB, Ultra2 Wide SCSI) GP5-144 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH94 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) GP5-HDH81 y Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm) (Hot Plug) GP5-HDH82 Server Monitor Module GP5USM102 Others i Redundant Power Supply Unit GP5UPU131 14 System Configuration teamserver G800i series (Jan.1999) tearserver G800i series CPU : Pentium®III (500MHz) / Pentium®II (450MHz / 400MHz / 350MHz)✕1(~2) , Cache (L1+L2) : 32KB+512KB, Internal Hard disk bay : 8slots (Hot plug) , CD-ROM , On board LAN / On board SCSI, Intel LANDesk®Server Manager(std), Redundant Power Supply(option), Redundant Fan(std.) GP5G870L GP5G850L [Pedestal type] GP5G820L [1CPU / Pedestal Type] (March / 99) 1CPU(Pentium®III 500MHz), Memory : 64MB (ECC) , HDD : Option [1CPU / Pedestal Type] 1CPU(Pentium®II 450MHz), Memory : 64MB (ECC) , HDD : Option [1CPU / Pedestal Type] 1CPU(Pentium®II 400MHz), Memory : 64MB (ECC) , HDD : Option GP5G870LR GP5G850LR GP5G820LR [Rackmount type] [1CPU / Rackmount Type] (March / 99) 1CPU(Pentium®III 500MHz), Memory : 64MB (ECC) , HDD : Option [1CPU / Rackmount Type] 1CPU(Pentium®II 450MHz), Memory : 64MB (ECC) , HDD : Option [1CPU / Rackmount Type] 1CPU(Pentium®II 400MHz), Memory : 64MB (ECC) , HDD : Option CPU ® q ® ® Memory w Max : 2GB CPU Field Upgrade Kit (Pentium®III-500MHz (512KB) ✕1) GP5-FG10N (for G870i) CPU Field Upgrade Kit (Pentium®II-450MHz (512KB) ✕1) GP5-FG10G (for G850i) CPU Field Upgrade Kit (Pentium®II-400MHz (512KB) ✕1) GP5-FG10C (for G820i) Additional Memory - 64MB (64MB SDRAM-DIMM✕1) GP5-RM64F Standard memory : 64MB (64MB SDRAM-DIMM✕1) Additional Memory - 128MB (128MB SDRAM-DIMM✕1) GP5-RM12F Additional Memory - 256MB (256MB SDRAM-DIMM✕1) GP5-RM25F Additional Memory - 512MB (512MB SDRAM-DIMM✕1) GP5-RM51F Internal Hard Disk (1)Disk Addition / Duplexing e Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) (Max.8) GP5-HDH46 ❋Up to 8 disks in a teamserver Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) (Max.8) GP5-HDH95 BAY 1~6 : 4.5GB / 9.1GB / 18.2GB BAY 7~8 : 4.5GB / 9.1GB Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) (Max.8) GP5-HDH81 (2)Internal Disk Array y y RAID Card (Cache : 16MB) GP5U141 Hard Disk Drive - 4GB (Ultra2 Wide.7,200rpm) (Hot Plug) (Max.8) GP5-HDH46 RAID Card (Cache : 4MB, Internal use only) GP5U142 Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm) (Hot Plug) (Max.8) GP5-HDH95 RAID Card (Cache : 32MB, Ultra2 Wide SCSI) GP5-144 Hard Disk Drive - 18GB (Ultra2 Wide.7,200rpm) (Hot Plug) (Max.8) GP5-HDH81 Server Monitor Module GP5USM102 Others Redundant Power Supply Unit GP5UPU131 i NOTE : 2 PSUs are required as standard if any of the following are installed. 2CPUs or 5+HDDs or 3+PCIs Maximum 3PSUs can be instaled in G800i series. 15 System Configuration teamserver C800i series tearserver C800i series CPU : Pentium®III (500MHz) / Pentium®II (450MHz / 400MHz / 350MHz)✕1(~2) , Cache (L1+L2) : 32KB+512KB, Internal Hard disk bay : 4slots (Hot plug : 3slots) , CD-ROM, On board LAN, On board SCSI, Intel LANDesk®Server Manger GP5C870 GP5C850 GP5C821 GP5C810 [Pedestal type] [1CPU / Pedestal Type] (April / 99) 1CPU(Pentium®III 500MHz), Memory : 64MB (ECC) , HDD : Option [1CPU / Pedestal Type] 1CPU(Pentium®II 450MHz), Memory : 64MB (ECC) , HDD : Option [1CPU / Pedestal Type] 1CPU(Pentium®II 400MHz), Memory : 64MB (ECC) , HDD : Option [1CPU / Pedestal Type] 1CPU(Pentium®II 350MHz), Memory : 64MB (ECC) , HDD : Option GP5C870R GP5C850R [Rackmount type] GP5C821R GP5C810R [1CPU / Rackmount Type] (April / 99) 1CPU(Pentium®III 500MHz), Memory : 64MB (ECC) , HDD : Option [1CPU / Rackmount Type] 1CPU(Pentium®II 450MHz), Memory : 64MB (ECC) , HDD : Option [1CPU / Rackmount Type] 1CPU(Pentium®II 400MHz), Memory : 64MB (ECC) , HDD : Option [1CPU / Rackmount Type] 1CPU(Pentium®II 350MHz), Memory : 64MB (ECC) , HDD : Option CPU ® q ® ® ® Memory w CPU Field Upgrade Kit (Pentium®II-500MHz (512KB) ✕1) GP5-FG10N (for C870i) CPU Field Upgrade Kit (Pentium®II-450MHz (512KB) ✕1) GP5-FG10G (for C850i) CPU Field Upgrade Kit (Pentium®II-400MHz (512KB) ✕1) GP5-FG10C (for C820i) CPU Field Upgrade Kit (Pentium®II-350MHz (512KB) ✕1) GP5-FG10B (for C810i) Max : 1GB Additional Memory - 64MB (64MB SDRAM-DIMM✕1) GP5-RM64F Standard memory : 64MB (64MB SDRAM-DIMM✕1) Additional Memory - 128MB (128MB SDRAM-DIMM✕1) GP5-RM12F Additional Memory - 256MB (256MB SDRAM-DIMM✕1) GP5-RM25F Internal Hard Disk Total 4 disks(3Hot Plug and 1non-Hot Plug) can be installed. (1)Disk Addition to Hot Plug bays (Max . 3 disks) Hard Disk Drive - 4GB (Ultra Wide.7,200rpm) (Hot Plug) GP5-HDH44 e Hard Disk Drive - 9GB (Ultra Wide.7,200rpm) (Hot Plug) GP5-HDH92 Hard Disk Drive - 4GB (Ultra Wide.7,200rpm) (Hot Plug) GP5-HDH44 (2)Internal Disk Array(Maximum 3Hot Plug disks can be installed) y RAID Card (Cache : 16MB) GP5U141 RAID Card (Cache : 4MB Internal Hard disk only) GP5U142 GP5-831 SCSI Cable (Intl.) Hard Disk Drive - 9GB (Ultra Wide.7,200rpm) (Hot Plug) GP5-HDH92 RAID Card (Cache : 8MB Internal Hard disk only) GP5-143 GP5U142 and GP5-143 cannot be used in the same platform. y Server Monitor Module GP5USM102 (Feb.1999) (3)Disk Addition to a non-Hot Plug bay only one disk can be installed e Hard Disk Drive-4GB (7,200rpm) (non-Hot Plug) GP5-HD4G5 Hard Disk Drive - 9GB (7,200rpm) (non-Hot Plug) GP5-HD9G2 16 System Configuration teamserver C300i series termserver C300i series CPU : Pentium®II (400MHz)✕1, Cache (L1+L2) : 32KB+512KB, Internal Hard disk bay : 4slots , CD-ROM, On board LAN, Intel LANDesk®Server Manger(std.) GP5C320 [1CPU/Pedestal Type] 1CPU Pentium®II(400MHz) , Memory : 64MB(ECC SDRAM), HDD:Option CPU : Pentium®II (350MHz)✕1 , Cache (L1+L2) : 32KB+512KB, Internal Hard disk bay : 4slots, (1slot:5inch bay) CD-ROM, On board LAN, Intel LANDisk® Server Manager(std.) GP5C310 [1CPU / Pedestal Type] 1CPU Pentium®II (350MHz), Memory : 64MB (ECC SDRAM) , HDD : Option CPU:Celeron (300AMHz)✕1 , Cache (L1+L2) : 32KB+128KB, Internal Hard disk bay : 4slots, CD-ROM, ON board LAN, Intel LANDisk® Server Manager(std.) GP5C300 [1CPU / Pedestal Type] 1CPU(Celeron 300AMHz), Memory : 64MB (ECC SDRAM) , HDD : Option Memory w Max : 768MB Additional Memory-32MB (32MB SDRAM-DIMM ✕1) GP5-RM32H Standard memory : 64MB-DIMM✕1 Additional Memory-64MB (64MB SDRAM-DIMM ✕1) GP5-RM64H Additional Memory-128MB (128MB SDRAM-DIMM ✕1) GP5-RM12H Additional Memory-256MB (256MB SDRAM-DIMM ✕1) GP5-RM25H Internal Hard Disk Max : 4disks (1)Disk Addition Max : 2 (EIDE Disk) Hard Disk Drive-4GB (EIDE) (5400rpm) GP5-HD4E1 e Hard Disk Drive-8GB (EIDE) (5400rpm) GP5-HD8E1 (SCSI Disk) Max : 4 y SCSI Card GP5-125 SCSI Cable GP5-837 Hard Disk Drive-4GB (Ultra Wide. 7200rpm) (non-Hot plug) GP5-HD4G5 Hard Disk Drive-9GB (Ultra Wide. 7200rpm) (non-Hot plug) GP5-HD9G2 (2) Internal Disk Array Hard Disk Drive-4GB (Ultra Wide. 7200rpm) (non-Hot plug) GP5-HD4G5 y RAID Card (Cache : 16MB) GP5U141 SCSI Cable GP5-837 Hard Disk Drive-9GB (Ultra Wide. 7200rpm) (non-Hot plug) GP5-HD9G2 RAID Card (Cache : 4MB, For internal HDD only) GP5U142 RAID Card (Cache : 8MB, For internal HDD only) GP5-143 GP5U142 and GP5-143 cannot be used in the same platform. y Server Monitor Module GP5USM102 (Feb.1999) 17 System Configuration teamserver Internal Devices M800i G800i L800i C800i series series C300i series SCSI Card GP5-125 y y y SCSI Card GP5-125 y SCSI Card GP5U121 Internal Cable (Wide SCSI) to connect GP5-DL351 is attached to DLT unit Internal Cable (Wide SCSI) to connect GP5-ML301 is attached to Tape unit DLT unit (35GB) GP5-DL351 ❋Two 5 inch bays occupied Tape unit (MLR3) GP5-ML301 Only G800i Only C800i r DLT unit (20GB) GP5UDL201 ❋Two 5 inch bays occupied r Only G800i r DAT unit (intl.) (DDS3) GP5UDT301 ❋Only one GP5UDT301 can be installed in the lowest 5 inch bay in teamserver C800i and G800i. r y SCSI Card GP5-125 SCSI Cable GP5-838 Tape unit (SLR5) GP5USL501 Tape unit (NS20) GP5-NS201 18 System Configuration teamserver External Devices M800i G800i L800i C800i C300i series (Pedestal only) Maximaum 2 Hard Disk Cabinets can be connected to a server series series Hard Disk Cabinet-Single End (Please refer to page 20 for Rackmount configuration.) <(1)In case of Maximum 7 Hard Disk Units installed> Non-Disk Array y y y SCSI Card GP5-125 Only G800i y Only C800i y Disk Array y y SCSI Cable GP5MU823A SCSI Card GP5U121 SCSI Cable GP5MU829A RAID Card GP5U141 <(2)In case of Maximum 14 Hard Disk Units installed> Non-Disk Array y y y SCSI Cable GP5MU823A X2 SCSI Card GP5-125 X 2 Only G800i y Disk Array y Hard Disk Cabinet-Single End GP5MS621A Please refer below for inside configuration Hard Disk Cabinet-Single End GP5MS621A Please refer below for inside configuration SCSI Card GP5U121 X 2 Only C800i y Hard Disk Cabinet-Single End GP5MS621A Please refer below for inside configuration y SCSI Cable GP5MU829A X2 RAID Card GP5U141 Hard Disk Cabinet-Single End GP5MS621A Please refer below for inside configuration NOTE : The maximum 28 disks (2 Hard Disk Cabinets) can be connected to a server via one RAID Card (GP5U141). The maximum 14 disks (1 Hard Disk Cabinet) can be connected to a server via one SCSI Card. [Configuration of the inside of Hard Disk Cabinet-Single End] <(1)Maximum 7 Hard Disk Units installed> <(2)Maximum 14 Hard Disk Units installed> Hard Disk Drive-4GB (7,200rpm) GP5MHDH4GA Hard Disk Drive-4GB (7,200rpm) GP5MHDH4GA Hard Disk Drive-9GB (7,200rpm) GP5MHDH9GA Hard Disk Drive-9GB (7,200rpm) GP5MHDH9GA Power Supply Unit Rackmount GP5MPU101A Power Supply Unit Rackmount GP5MPU101A NOTE : Maximum 7 Hard Disk Units can be installed (Maximum 6 Hard Disk Units can be installed when a PSU is installed.) Additional Shelf GP5MS621SA Hard Disk Drive-4GB (7,200rpm) GP5MHDH4GA Hard Disk Drive-9GB (7,200rpm) GP5MHDH9GA Power Supply Unit Rackmount GP5MPU101A NOTE : Maximum 7 Hard Disk Units can be installed (Maximum 6 Hard Disk Units can be installed when a PSU is installed.) 19 System Configuration teamserver Rackmount 40U Rack GP5-R1RC2 40U Rack & Rack Coupling kit GP5-R1RC3 ❋A maximum of two servers can be installed in a Rack system. ❋The Rack Coupling kit is used for connecting two Racks together. Component Shelf GP5-R1TB4 teamserver CPU nodes for Rackmount Keyboard/Monitor Extention Cables GP5-411 Key board/Monitor Enhanced Switch GP5-SB101 Enhanced keyboard GP5-R1KB2 M800i / L800i / G800i y SCSI Card GP5-125 SCSI Cable GP5MU823A SCSI Card GP5U121 SCSI Cable GP5MU823A RAID Card GP5U141 SCSI Cable GP5MU830A C800i Keyboard/Monitor Shelf Kit GP5-R1TB3 Storage System GP5UR1DC2 ❋The number of these cabinets depends on the configuration. M800i / L800i / G800i y SCSI Card GP5-126 SCSI Cable GP5MU823A RAID Card GP5-144 SCSI Cable GP5S-832 [Inside of Storage System] Hard Disk Drive-4GB(7,200rpm) GP5-HDH45 Hard Disk Drive-9GB(7,200rpm) GP5-HDH93 Hard Disk Drive-9GB(10,000rpm) GP5-HDH94 Hard Disk Drive-18GB(7,200rpm) GP5-HDH81 Hard Disk Drive-18GB(10,000rpm) GP5-HDH82 Redundant Power Supply Unit GP5UR1PU1 NOTE : A maximum of eight Hard Disk Drives can be installed in a Storage System. In a RAID configuration, a physical pack must be comprised by the same type of hand disks. 20 Storage System(Ultra2 Wide) GP5UR1DC3 ❋The number of this cabinet depends on the configuration. System Configuration Network Cards teamserver M800i G800i L800i C800i C300i series series series y y LAN Card GP5-183 y y y LAN Card GP5-182 teamserver Cluster System Configuration (U.S. only) Cluster System using Microsoft® Windows NT Server , Enterprise Edition V4.0 teamserver M800i/L800i/G800i y SCSI Card GP5-123 SCSI Cable (Procured locally) y teamserver M800i / L800i / G800i LVS Disk Array (U.S. only) y y SCSI Cable (Procured locally) SCSI Card GP5-123 21 teamserver Hardware Folowing models (Pentium II Xeon 450MHz models) are Available from Feb.1999 Product teamserverM861i Product ID GP5M861LR Remarks Pentium II Xeon 450MHz with 2MB Cache (x2, up to 8CPUs) , 512MB EDO-DIMM with ECC,50ns ( 16GB maximum ) (Rackmount) PCI64bitx10,PCI32bitx11,ISA/PCI32bitx1 , 24xCD-ROM,FDD,Fast narrow SCSI controller is on board (June 1999) 12Internal HDD bays (Ultra2wide SCSI/Hot plug) - 76bays maximum : Intl. HDD(12)+GP5UR1DC3x8 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM * Windows NT4.0 supports up to 4CPUs and 4GB Memory, more than that supported by Windows NT 4.0E.E teamserverM851i GP5M851LR Pentium II Xeon 450MHz with 1MB Cache (x2, up to 8CPUs) , 512MB EDO-DIMM with ECC,50ns ( 16GB maximum ) (Rackmount) PCI64bitx10,PCI32bitx11,ISA/PCI32bitx1 , 24xCD-ROM,FDD,Fast narrow SCSI controller is on board (June 1999) 12Internal HDD bays (Ultra2wide SCSI/Hot plug) - 76bays maximum : Intl. HDD(12)+GP5UR1DC3x8 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM * Windows NT4.0 supports up to 4CPUs and 4GB Memory, more than that supported by Windows NT 4.0E.E teamserverM860i GP5M860L Pentium II Xeon 450MHz with 2MB Cache (x1, up to 8CPUs) , 256MB EDO-DIMM with ECC, 50ns (8GB maximum) PCI64bitx5,PCI32bitx5,ISA/PCI32bitx1,24xCD-ROM,FDD,Fast narrow SCSI controller is on board 6Internal HDD bays (Ultra2wide SCSI/Hot plug) - 14bays maximum : Intl. HDD(6)+GP5UR1DC3 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM * Windows NT4.0 supports up to 4CPUs and 4GB Memory, more than that supported by Windows NT 4.0E.E teamserverM860i GP5M860LR (Rackmount) Pentium II Xeon 450MHz with 2MB Cache (x1, up to 8CPUs) , 256MB EDO-DIMM with ECC,50ns ( 8GB maximum ) PCI64bitx5,PCI32bitx5,ISA/PCI32bitx1,24xCD-ROM,FDD,Fast narrow SCSI controller is on board 6Internal HDD bays (Ultra2wide SCSI/Hot plug) - 76bays maximum : Intl. HDD(12)+GP5UR1DC3x8 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM * Windows NT4.0 supports up to 4CPUs and 4GB Memory, more than that supported by Windows NT 4.0E.E teamserverM850i GP5M850 (June 1999) Pentium II Xeon 450MHz with 1MB Cache (x1, up to 8CPUs) , 256MB EDO-DIMM with ECC,50ns ( 8GB maximum ) PCI64bitx5,PCI32bitx5,ISA/PCI32bitx1,24xCD-ROM,FDD,Fast narrow SCSI controller is on board 6Internal HDD bays (Ultra2wide SCSI/Hot plug) - 14bays maximum : Intl. HDD(6)+GP5UR1DC3 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM * Windows NT4.0 supports up to 4CPUs and 4GB Memory, more than that supported by Windows NT 4.0E.E teamserverM850i GP5M850LR Pentium II Xeon 450MHz with 1MB Cache (x1, up to 8CPUs) , 256MB EDO-DIMM with ECC,50ns ( 8GB maximum ) (Rackmount) PCI64bitx5,PCI32bitx5,ISA/PCI32bitx1,24xCD-ROM,FDD,Fast narrow SCSI controller is on board (June 1999) 6Internal HDD bays (Ultra2wide SCSI/Hot plug) - 76bays maximum : Intl. HDD(12)+GP5UR1DC3x8 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM * Windows NT4.0 supports up to 4CPUs and 4GB Memory, more than that supported by Windows NT 4.0E.E teamserverM850ic GP5M850AL Pentium II Xeon 450MHz with 1MB Cache (x1, up to 4CPUs) , 256MB EDO-DIMM with ECC,50ns ( 8GB maximum ) PCI64bitx5,PCI32bitx5,ISA/PCI32bitx1,24xCD-ROM,FDD,Fast narrow SCSI controller is on board 6Internal HDD bays (Ultra2wide SCSI/Hot plug) - 14bays maximum : Intl.HDD(6)+GP5UR1DC3 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM * Windows NT4.0 supports up to 4CPUs and 4GB Memory, more than that supported by Windows NT 4.0E.E teamserverM850ic (Rackmount) GP5M850BL Pentium II Xeon 450MHz with 1MB Cache (x1, up to 4CPUs) , 256MB EDO-DIMM with ECC,50ns ( 8GB maximum ) PCI64bitx5,PCI32bitx5,ISA/PCI32bitx1,24xCD-ROM,FDD,Fast narrow SCSI controller is on board 6Internal HDD bays (Ultra2wide SCSI/Hot plug) - 62 bays maximum : Intl. HDD(6)x1 +GP5UR1DC3x7 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM * Windows NT4.0 supports up to 4CPUs and 4GB Memory, more than that supported by Windows NT 4.0E.E 22 teamserver Hardware Product teamserverM840i Product ID GP5M840L (Feb.1999) Remarks Pentium II Xeon 450MHz with 512KB Cache (x1, up to 4CPUs) , 256MB EDO-DIMM with ECC,50ns ( 8GB maximum ) PCI64bitx5,PCI32bitx5,ISA/PCI32bitx1,24xCD-ROM,FDD,Fast narrow SCSI controller is on board 6Internal HDD bays (Ultra2wide SCSI/Hot plug) - 14bays maximum : Intl.HDD(6)+GP5UR1DC3 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM * Windows NT4.0 supports up to 4CPUs and 4GB Memory, more than that supported by Windows NT 4.0E.E teamserverM840i GP5M840LR (Rackmount) Pentium II Xeon 450MHz with 512KB Cache (x1, up to 4CPUs) , 256MB EDO-DIMM with ECC,50ns ( 8GB maximum ) PCI64bitx5,PCI32bitx5,ISA/PCI32bitx1,24xCD-ROM,FDD,Fast narrow SCSI controller is on board 6Internal HDD bays (Ultra2wide SCSI/Hot plug) - 62 bays maximum : Intl. HDD(6)x1 +GP5UR1DC3x7 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM * Windows NT4.0 supports up to 4CPUs and 4GB Memory, more than that supported by Windows NT 4.0E.E teamserverL850i GP5L850L Pentium II Xeon 450MHz with 1MB Cache (x1, up to 4CPUs) , 128MB EDO-DIMM with ECC,50ns ( 4GB maximum ) PCIx6ISA/PCIx1,24xCD-ROM,FDD,2xUltra2wide&1x Fast narrow SCSI is on board 8Internal HDD bays (Ultra2Wide SCSI/Hot plug) 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM,Wakeup On LAN teamserverL850i GP5L850LR (Rackmount) Pentium II Xeon 450MHz with 1MB Cache (x1, up to 4CPUs) , 128MB EDO-DIMM with ECC,50ns ( 4GB maximum ) PCIx6ISA/PCIx1,24xCD-ROM,FDD,2xUltra2wide&1x Fast narrow SCSI is on board 8Internal HDD bays (Ultra2Wide SCSI/Hot plug) - 40bays maximum : Intl. HDD(8)+GP5UR1DC3x4 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM,Wakeup On LAN teamserverL840i GP5L840L Pentium II Xeon 450MHz with 512KB Cache (x1, up to 4CPUs) , 128MB EDO-DIMM with ECC,50ns ( 4GB maximum ) PCIx6ISA/PCIx1,24xCD-ROM,FDD,2xUltra2wide&1x Fast narrow SCSI is on board 8Internal HDD bays (Ultra2Wide SCSI/Hot plug) - 40bays maximum : Intl. HDD(8)+GP5UR1DC3x4 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM,Wakeup On LAN teamserverL840i (Rackmount) GP5L840R Pentium II Xeon 450MHz with 512KB Cache (x1, up to 4CPUs) , 128MB EDO-DIMM with ECC,50ns ( 4GB maximum ) PCIx6ISA/PCIx1,24xCD-ROM,FDD,2xUltra2wide&1x Fast narrow SCSI is on board 8Internal HDD bays (Ultra2Wide SCSI/Hot plug) - 40bays maximum : Intl. HDD(8)+GP5UR1DC3x4 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM,Wakeup On LAN 23 teamserver Hardware Product teamserverG870i Product ID GP5G870L Remarks Pentium III 500MHz with 512KB Cache (x1, up to 2CPUs) , 64MB SDRAM (Single DIMM with ECC,2GB maximum ) PCIx4Shared (ISA/PCI)x1ISAx1,32xCD-ROM,FDD,2xUltra2wide&1x Fast narrow SCSI is on board 8Internal HDD bays (Ultra2Wide SCSI/Hot plug) 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM,Wakeup On LAN teamserverG870i GP5G870LR Pentium III 500MHz with 512KB Cache (x1, up to 2CPUs) , 64MB SDRAM (Single DIMM with ECC,2GB maximum ) PCIx4Shared (ISA/PCI)x1ISAx1,32xCD-ROM,FDD,2xUltra2wide&1x Fast narrow SCSI is on board (Rackmount) 8Internal HDD bays (Ultra2Wide SCSI/Hot plug) - 40bays maximum : Intl. HDD(8)+GP5UR1DC3x4 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM,Wakeup On LAN teamserverG850i GP5G850L Pentium II 450MHz with 512KB Cache (x1, up to 2CPUs) , 64MB SDRAM (Single DIMM with ECC,2GB maximum ) PCIx4Shared (ISA/PCI)x1ISAx1,32xCD-ROM,FDD,2xUltra2wide&1x Fast narrow SCSI is on board 8Internal HDD bays (Ultra2Wide SCSI/Hot plug) 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM,Wakeup On LAN teamserverG850i GP5G850LR (Rackmount) Pentium II 450MHz with 512KB Cache (x1, up to 2CPUs) , 64MB SDRAM (Single DIMM with ECC,2GB maximum ) PCIx4Shared (ISA/PCI)x1ISAx1,32xCD-ROM,FDD,2xUltra2wide&1x Fast narrow SCSI is on board 8Internal HDD bays (Ultra2Wide SCSI/Hot plug) - 40bays maximum : Intl. HDD(8)+GP5UR1DC3x4 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM,Wakeup On LAN teamserverG820i GP5G820L Pentium II 400MHz with 512KB Cache (x1, up to 2CPUs) , 64MB SDRAM (Single DIMM with ECC,2GB maximum ) PCIx4Shared (ISA/PCI)x1ISAx1,32xCD-ROM,FDD,2xUltra2wide&1x Fast narrow SCSI is on board 8Internal HDD bays (Ultra2Wide SCSI/Hot plug) 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM,Wakeup On LAN teamserverG820i GP5G820LR (Rackmount) Pentium II 400MHz with 512KB Cache (x1, up to 2CPUs) , 64MB SDRAM (Single DIMM with ECC,2GB maximum ) PCIx4Shared (ISA/PCI)x1ISAx1,32xCD-ROM,FDD,2xUltra2wide&1x Fast narrow SCSI is on board 8Internal HDD bays (Ultra2Wide SCSI/Hot plug) - 40bays maximum : Intl. HDD(8)+GP5UR1DC3x4 100Base-TX/10Base-T,Hot plug PSU,Hot plug Fan,LDSM,Wakeup On LAN teamserverC870i GP5C870 Pentium II 500MHz with 512KB Cache (x1, up to 2CPUs) , 64MB SDRAM (Single DIMM with ECC,1GB maximum ) PCIx3,ISAx2,32xCD-ROM,FDD,1xUltrawide&1xFast narrow SCSI is on board 4Internal HDD bays (Ultra Wide SCSI/3xHot plug) - 32bays maximum : Intl. HDD(4)+(GP5MS621A+GP5MS621SA)x2 100Base-TX/10Base-T,LDSM,Wakeup On LAN teamserverC870i GP5C870R (Rackmount) Pentium III 500MHz with 512KB Cache (x1, up to 2CPUs) , 64MB SDRAM (Single DIMM with ECC,1GB maximum ) PCIx3,ISAx2,32xCD-ROM,FDD,1xUltrawide&1xFast narrow SCSI is on board 4Internal HDD bays (Ultra Wide SCSI/3xHot plug) - 36bays maximum : Intl. HDD(4)+GP5UR1DC2x4 100Base-TX/10Base-T,LDSM,Wakeup On LAN teamserverC850i GP5C850 Pentium II 450MHz with 512KB Cache (x1, up to 2CPUs) , 64MB SDRAM (Single DIMM with ECC,1GB maximum ) PCIx3,ISAx2,32xCD-ROM,FDD,1xUltrawide&1xFast narrow SCSI is on board 4Internal HDD bays (Ultra Wide SCSI/3xHot plug) - 32bays maximum : Intl. HDD(4)+(GP5MS621A+GP5MS621SA)x2 100Base-TX/10Base-T,LDSM,Wakeup On LAN teamserverC850i (Rackmount) GP5C850R Pentium II 450MHz with 512KB Cache (x1, up to 2CPUs) , 64MB SDRAM (Single DIMM with ECC,1GB maximum ) PCIx3,ISAx2,32xCD-ROM,FDD,1xUltrawide&1xFast narrow SCSI is on board 4Internal HDD bays (Ultra Wide SCSI/3xHot plug) - 36bays maximum : Intl. HDD(4)+GP5UR1DC2x4 100Base-TX/10Base-T,LDSM,Wakeup On LAN 24 teamserver Hardware Product teamserverC820i Product ID GP5C821 Remarks Pentium II 400MHz with 512KB Cache (x1, up to 2CPUs) , 64MB SDRAM (Single DIMM with ECC,1GB maximum ) PCIx3,ISAx2,32xCD-ROM,FDD,1xUltrawide&1xFast narrow SCSI is on board 4Internal HDD bays (Ultra Wide SCSI/3xHot plug) - 32bays maximum : Intl. HDD(4)+(GP5MS621A+GP5MS621SA)x2 100Base-TX/10Base-T,LDSM,Wakeup On LAN teamserverC820i GP5C821R (Rackmount) Pentium II 400MHz with 512KB Cache (x1, up to 2CPUs) , 64MB SDRAM (Single DIMM with ECC,1GB maximum ) PCIx3,ISAx2,32xCD-ROM,FDD,1xUltrawide&1xFast narrow SCSI is on board 4Internal HDD bays (Ultra Wide SCSI/3xHot plug) - 36bays maximum : Intl. HDD(4)+GP5UR1DC2x4 100Base-TX/10Base-T,LDSM,Wakeup On LAN teamserverC810i GP5C810 Pentium II 350MHz with 512KB Cache (x1, up to 2CPUs) , 64MB SDRAM (Single DIMM with ECC,1GB maximum ) PCIx3,ISAx2,32xCD-ROM,FDD,1xUltrawide&1xFast narrow SCSI is on board 4Internal HDD bays (Ultra Wide SCSI/3xHot plug) - 32bays maximum : Intl. HDD(4)+(GP5MS621A+GP5MS621SA)x2 100Base-TX/10Base-T,LDSM,Wakeup On LAN teamserverC810i GP5C810R (Rackmount) Pentium II 350MHz with 512KB Cache (x1, up to 2CPUs) , 64MB SDRAM (Single DIMM with ECC,1GB maximum ) PCIx3,ISAx2,32xCD-ROM,FDD,1xUltrawide&1xFast narrow SCSI is on board 4Internal HDD bays (Ultra Wide SCSI/3xHot plug) - 36bays maximum : Intl. HDD(4)+GP5UR1DC2x4 100Base-TX/10Base-T,LDSM,Wakeup On LAN teamserver C320i GP5C320 Pentium II 400MHz with 512KB Cache (x1),64MB Unbuffered SDRAM (Single DIMM with ECC,768MB maximum) PCIx4,ISAx1, 3x3.5''/1x5'' HDD bays (Ultrawide SCSI /EIDE, non-Hot plug) - 32bays maximum : Intl. HDD(4)+(GP5MS621A+GP5MS621AS)x2 32xCD-ROM,FDD, 100Base-TX/10Base-T,LDSM,Wakeup On LAN teamserver C310i GP5C310 Pentium II 350MHz with 512KB Cache (x1),64MB Unbuffered SDRAM (Single DIMM with ECC,768MB maximum) PCIx4,ISAx1, 3x3.5''/1x5'' HDD bays (Ultrawide SCSI /EIDE, non-Hot plug) - 32bays maximum : Intl. HDD(4)+(GP5MS621A+GP5MS621SA)x2 32xCD-ROM,FDD, 100Base-TX/10Base-T,LDSM,Wakeup On LAN teamserver C300i GP5C300 Celeron 300AMHz with 128KB Cache (x1),64MB Unbuffered SDRAM (Single DIMM with ECC,768MB maximum) PCIx4,ISAx1, 3x3.5''/1x5'' HDD bays (Ultrawide SCSI /EIDE, non-Hot plug) - 32bays maximum : Intl. HDD(4)+(GP5MS621A+GP5MS621SA)x2 32xCD-ROM,FDD, 100Base-TX/10Base-T,LDSM,Wakeup On LAN 25 teamserver Hardware CPU Field Upgrade Kit C300i C310i C320i C810i C820i C850i C870i G820i G850i L840i G870i L850i M840i M850i M850ic M860i Produt ID M851i Product M861i Models GP5-FG10M ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Remarks P-II Xeon(450MHz)/32KB+2MBcachex1,Placed on motherboard Include one CPU and dedicated power supply module(VRM) CPU Field Upgrade Kit GP5-FG10K ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ P-II Xeon(450MHz)/32KB+1MBcachex1,Placed on motherboard Include one CPU and dedicated power supply module(VRM) CPU Field Upgrade Kit GP5-FG10H ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ P-II Xeon(450MHz)/32KB+512KBcachex1,Placed on motherboard Include one CPU and dedicated power supply module(VRM) CPU Field Upgrade Kit GP5-FG10F ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ P-II Xeon(400MHz)/32KB+1MBcachex1,Placed on motherboard Include one CPU and dedicated power supply module(VRM) CPU Field Upgrade Kit GP5-FG10D ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ PIIXeon(400MHz)/32KB+512KBx1, Placed on motherboard Include one CPU and dedicated power supply module(VRM) CPU Cabinet Upgrade Kit GP5U78C1UL ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ (June 1999) CPU Cabinet Upgrade Kit and one CPU(P-II Xeon 400MHz/1MB LVD) GP5U85L1 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ (June 1999) CPU Cabinet Upgrade Kit Upgrade Option 4way to 8way, Only for M850i Slave node,MCU Cardx2, fibre Cable and one CPU(P-II Xeon 450MHz/1MB) GP5U86L2 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ (June 1999) CPU Field Upgrade Kit Upgrade Option 4way to 8way, Only for M830i Slave node,MCU Cardx2, fibre Cable Upgrade Option 4way to 8way, Only for M860i Slave node,MCU Cardx2, fibre Cable and one CPU(P-II Xeon 450MHz/2MB) GP5-FG10N ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ PIII(500MHz)/32KB+512KB, for G870i/C870i G870i:Placed on CPU memory board, C870i:Placed on motherboard Only use with processors of same size and type CPU Field Upgrade Kit GP5-FG10G ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ PII(450MHz)/32KB+512KB, for G850i/C850i G850i:Placed on CPU memory board, C850i:Placed on motherboard Only use with processors of same size and type CPU Field Upgrade Kit GP5-FG10C ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ PII(400MHz)/32KB+512KBx1, for G820i/C820i C820i:Placed on CPU memory board, C820i:Placed on motherboard Only use with processors of same size and type CPU Field Upgrade Kit GP5-FG10B ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ PII(350MHz)/32KB+512KBx1, for G810i/C810i G810i:Placed on CPU memory board, C810i:Placed on motherboard Only use with processors of same size and type Additional Memory 1GB GP5-RM1G ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ EDO-DIMM(Buffered;50ns)256MBx4 Additional Memory 512MB GP5-RM51G ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ EDO-DIMM(Buffered;50ns)128MBx4 Additional Memory 256MB GP5-RM25G ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ EDO-DIMM(Buffered;50ns)64MBx4 Additional Memory 128MB GP5-RM12G ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ EDO-DIMM(Buffered;50ns)32MBx4 Additional Memory 512MB GP5-RM51F ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ SDRAM-DIMM 512MBx1 (Registered 100MHz) Additional Memory 256MB GP5-RM25F ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ SDRAM-DIMM 256MBx1 (Registered 100MHz) Additional Memory 128MB GP5-RM12F ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ SDRAM-DIMM 128MBx1 (Registered 100MHz) Additional Memory 64MB GP5-RM64F ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ SDRAM-DIMM 64MBx1 (Registered 100MHz) Additional Memory 256MB GP5-RM25H ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Unbuffered SDRAM-DIMM 256MBx1 Additional Memory 128MB GP5-RM12H ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Unbuffered SDRAM-DIMM 128MBx1 (Mar.1999) Additional Memory 64MB GP5-RM64H ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Unbuffered SDRAM-DIMM 64MBx1 Additional Memory 32MB GP5-RM32H ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Unbuffered SDRAM-DIMM 32MBx1 HDD-18GB GP5-HDH82 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 18.2GB,Ultra2wide SCSI,10000rpm,SCA2 80pin,Hotplug for M8xxi,L8xxi,also Storage System(GP5UR1DC2/3) HDD-9GB GP5-HDH94 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 9.1GB,Ultra2wide SCSI,10000rpm,SCA2 80pin,Hotplug for M8xxi,L8xxi,also Storage System(GP5UR1DC2/3) 26 teamserver Hardware HDD-18GB C300i C310i C320i C810i C820i C850i C870i G820i G850i L840i G870i L850i M840i M850i M850ic M860i Produt ID M851i Product M861i Models GP5-HDH81 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Remarks 18.2GB,Ultra2wide SCSI,7200rpm,SCA2 80pin,Hotplug for M8xxi,L8xxi,also Storage System(GP5UR1DC2/3) HDD-9GB GP5-HDH93 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 9.1GB,Ultra2wide SCSI,7200rpm,SCA2 80pin,Hotplug for M8xxi,L8xxi,also Storage System(GP5UR1DC2/3) HDD-4GB GP5-HDH45 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 4.5GB,Ultra2wide SCSI,7200rpm,SCA2 80pin,Hotplug for M8xxi,L8xxi,also Storage System(GP5UR1DC2/3) HDD-9GB GP5-HDH95 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 9.1GB,Ultra2wide SCSI,7200rpm,SCA2 80pin,Hotplug for G8xxi HDD-4GB GP5-HDH46 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 4.3GB,Ultra2wide SCSI,7200rpm,SCA2 80pin,Hotplug for G8xxi HDD-9GB GP5-HDH92 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 9.1GB,Ultrawide SCSI,7200rpm,SCA2 80pin,Hotplug for C8xxi HDD-4GB GP5-HDH44 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 4.3GB,Ultrawide SCSI,7200rpm,SCA2 80pin,Hotplug for C8xxi HDD-9GB GP5-HD9G2 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 9.1GB,Ultrawide SCSI,7200rpm,68pin, Non Hotplug for C8xxi(Mounted in Non Hotplug bay),C3xxi HDD-4GB GP5-HD4G5 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 4.3GB,Ultrawide SCSI,7200rpm,68pin, Non Hotplug for C8xxi(Mounted in Non Hotplug bay),C3xxi HDD-8GB(EIDE) GP5-HD8E1 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ EIDE,5400rpm, 8.4GB, for C320i/310i/300i HDD-4GB(EIDE) GP5-HD4E1 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ EIDE,5400rpm, 4.3GB, for C320i/310i/300i HDD-9GB GP5MHDH9GA - - - - - - - - - - - - - - - - - - 9.1GB,Ultrawide SCSI,7200rpm, Hotplug Only for Hard Disk Cabinet(GP5MS621S,GP5MS621SA) HDD-4GB GP5MHDH4GA - - - - - - - - - - - - - - - - - - 4.3GB,Ultrawide SCSI,7200rpm, Hotplug Only for Hard Disk Cabinet(GP5MS621S,GP5MS621SA) DAT unit (DDS-3) GP5UDT301 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ DDS-3 (12-24GB) *The backup utility can be used with the NTBACKUP for Windows NT4.0 and ARC serve for Windows NT6.0.(Windows NT3.51 is not supported), The ARC serve for Windows NT6.0.needs Service Pack 3 or greater. Media is not included. Only one can be mounted in the lowest 5''bay (G8xxi/C8xxi),SCSI2 Tape unit (SLR5) GP5USL501 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ SLR5 (4-8GB) Backup utilities: NTBACKUP,SBACKUP,ARCserve for Windows NT4.0,ARCserve for Netware 6.5 Media is not supplied. SCSI2 DLT unit GP5UDL201 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ DLT4000SE Narrow (20-40GB) Required S/W :ARCserve for Windows NT6.0 or greater (Windows NT4.0),, ARCserve Storage Suite 6.5 or greater(BackOffice small BusinessServer 4.0) *NTBACKUP,SBACKUP can not be used as a backup device. Two bays required and occupied. Cleaning cartridgex1/Data cartridgex1 is attached. SCSI2 DLT unit GP5-DL351 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ DLT7000SE Wide (35-70GB) Required S/W :ARCserve for Windows NT6.0 or greater (Windows NT4.0), ARCserve Storage Suite 6.5 or greater(BackOffice small BusinessServer 4.0) *NTBACKUP,SBACKUP can not be used as a backup device. Two bays required and occupied. SCSI Adapter(GP5-125)is required to connect. Cleaning cartridgex1/Data cartridgex1/Internal SCSI cable(with terminal register)is attached. Tape unit (MLR3) GP5-ML301 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ MLR3 (25-50GB) The backup utility can be used with NTBACKUP, ARCserve for WindowsNT J6.5 L20(Windows NT4.0), NTBACKUP, ARCserve Storage. SCSI Adapter(GP5U121/GP5-125)is required to connect. TRAVAN NS unit(NS20) GP5-NS201 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ TRAVAN NS20 (10-20GB) The backup utility can be used with NTBACKUP, ARCserve for WindowsNT J6.5 L20(Windows NT4.0), NTBACKUP, ARCserve Storage Suite J6.5 Redundant Power Supply Unit GP5UPU131 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 27 Redundant PSU (450W) teamserver Hardware C300i C310i C320i C810i C820i C850i C870i G820i G850i L840i G870i L850i M840i M850i M850ic M860i Produt ID M851i Product M861i Models Redundant Power Supply Unit GP5UPU141 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ R/P R/P R/P R/P R R R R R R R R R R R R Redundant Power Supply Unit GP5UR1PU1 Power Supply Unit GP5MPU101A P P P P P P P P P P P P P P P P P P Rackmount Pattern BR GP5R8K1 R R R R R R R R R R R R R R R R R R Remarks Redundant PSU (350W) Redundant PSU for Storage System (GP5UR1DC2/GP5UR1DC3), (365W) Redundant PSU for HD Cabinet (GP5MS621A), (180W) Basic/Additional Rack Pattern K-1 for C/G/L8xxi Rackmount Pattern BR GP5R8K2 R R R R R R R R R R R R R R R R R R Basic/Additional Rack Pattern K-2 for C/G/L8xxi Rackmount Pattern BR GP5R8K3 R R R R R R R R R R R R R R R R R R Basic/Additional Rack Pattern K-3 for C/G/L8xxi Rackmount Pattern BR GP5R8K4 R R R R R R R R R R R R R R R R R R Basic/Additional Rack Pattern K-4 for C/G/L8xxi Rackmount Pattern BR GP5R8K5 R R R R R R R R R R R R R R R R R R Basic/Additional Rack Pattern K-5 for C/G/L8xxi Rackmount Pattern BR GP5R8K6 R R R R R R R R R R R R R R R R R R Basic/Additional Rack Pattern K-6 for C/G/L8xxi Rackmount Pattern BR GP5R8K7 R R R R R R R R R R R R R R R R R R Basic/Additional Rack Pattern K-7 for C/G/L8xxi Rackmount Pattern BR GP5R8K8 R R R R R R R R R R R R R R R R R R Basic/Additional Rack Pattern K-8 for C/G/L8xxi Rackmount Pattern BR GP5M8K1 ■ ■ R R R R R R ■ R R R R R R R R R Basic/Additional Rack Pattern K-1 for M8xxi Rackmount Pattern BR GP5M8K2 ■ ■ R R R R R R ■ R R R R R R R R R Basic/Additional Rack Pattern K-2 for M8xxi Rackmount Pattern BR GP5M8K3 ■ ■ R R R R R R ■ R R R R R R R R R Basic/Additional Rack Pattern K-3 for M8xxi Rackmount Pattern BR GP5M8K4 ■ ■ R R R R R R ■ R R R R R R R R R Basic/Additional Rack Pattern K-4 for M8xxi Rackmount Pattern BR GP5M8K5 ■ ■ R R R R R R ■ R R R R R R R R R Basic/Additional Rack Pattern K-5 for M8xxi Rackmount Pattern BR GP5M8K6 ■ ■ R R R R R R ■ R R R R R R R R R Basic/Additional Rack Pattern K-6 for M8xxi Rackmount Pattern AR GP5AR8K1 ■ ■ R R R R R R R R R R R R R R R R Additional Rack Pattern Z-1 for C/G/L/M8xxi Rackmount Pattern AR GP5AR8K2 ■ ■ R R R R R R R R R R R R R R R R Additional Rack Pattern Z-2 for C/G/L/M8xxi Rackmount Pattern AR GP5AR8K3 ■ ■ R R R R R R R R R R R R R R R R Additional Rack Pattern Z-3 for C/G/L/M8xxi Rackmount Pattern AR GP5AR8K4 ■ ■ R R R R R R R R R R R R R R R R Additional Rack Pattern Z-4 for C/G/L/M8xxi Rackmount Pattern AR GP5AR8K5 ■ ■ R R R R R R R R R R R R R R R R Additional Rack Pattern Z-5 for C/G/L/M8xxi Rackmount Pattern AR GP5AR8K6 ■ ■ R R R R R R R R R R R R R R R R Additional Rack Pattern Z-6 for C/G/L/M8xxi 40U Rack GP5-R1RC2 ■ ■ R R R R R R R R R R R R R R R R 19'' 40U Locker , Front door,rear door,side panel,earthquake proof board , blank panel is attached. Size(WxDxH)mm:600x900x2035 C8xxi:6U, G8xxi:7U, L8xxi:7U, M840/850/860/850ic:10U, M851i/861i:20U GP5UR1DC2/GP5UR1DC3:4U UPS(1400VA):3U, UPS(3000VA):5U Keyboard/Monitor Shelf:9U(for installation 15''CRT), 2U(for installation Keyboard) Component shelf:4U CRT/KB switch:Mounted at side of CRT(occupies same U as CRT) 40U Rack&Rack Coupling Kit GP5-R1RC3 ■ ■ R R R R R R R R R R R R R R R R 19''40U Locker + connection metal fittings Front door,rear door,concatenation frame,blank panel is attached. Size(WxDxH)mm:600x900x2035 Units can be installed as for GP5-R1RC2 Component Shelf GP5-R1TB4 ■ ■ R R R R R R R R R R R R R R R R 28 Shelf to fit peripheral device into 40U Rack, Table size:400x500 teamserver Hardware Keyboard/Monitor Shelf Kit GP5-R1TB3 C300i C310i C320i C810i C820i C850i C870i G820i G850i L840i G870i L850i M840i M850i M850ic M860i Produt ID M851i Product M861i Models ■ ■ R R R R R R R R R R R R R R R R Remarks CRT/KB shelf for Rackmountable type *Only a 15''CRT can be installed on the CRT storage table. Keyboard/Monitor Enhanced Switch GP5-SB101 ■ ■ R R R R R R R R R R R R R R R R Switch enables sharing of a set of CRT,keyboard,and mouse by two or more servers (up to four servers). CRT/KB cable, CRT cable, KB/mouse cable is prepared separately. Keyboard/Monitor Extension Cables GP5-411 ■ ■ R R R R R R R R R R R R R R R R CRT/KB cable , (CRT cablex1,KB cablex1 is attached) Enhanced Keyboard GP5-R1KB2 ■ ■ R R R R R R R R R R R R R R R R 87Key keyboard for Rackmountable type Storage System (Ultrawide SCSI) GP5UR1DC2 ■ ■ R R R R R R R R R R R R R R R R 8Hard Disk Drive Bays(Hotplugable) Redundant HD/FAN(Two as a standard eqipment)/PSU(A GP5UR1PU1 is a standard equipment, up to two) GP5-HDH45/HDH93/HDH81/ HDH94/HDH82 can be mounted. Ultrawide SCSI Storage System (Ultra2wide SCSI) GP5UR1DC3 ■ ■ R R R R R R R R R R R R R R R R 8Hard Disk Drive Bays(Hotplugable) Redundant HD/FAN(Two as a standard eqipment)/PSU(A GP5UR1PU1 is a standard equipment, up to two) GP5-HDH45/HDH93/HDH81/ HDH94/HDH82 can be mounted. Ultra2wide SCSI Hard Disk Cabinet (Single End) GP5MS621A P P P P P P P P P P P P P P P P P P 7Hard Disk Dirve Bays(Hotplugable) 14Bays is maximum (GP5MS621SA is used) Redundant HD/FAN(Up to two)/PSU(GP5MSPU101A is standard equipment, up to two) GP5MHDH4GA/9GA can be mounted. Ultrawide SCSI Additional Shelf SCSI Card GP5MS621SA P P P P P P P P P P P P P P P P P P GP5U121 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Additional shelf only for GP5MS621A, Same as the basic shelf Ultrawide, SE, x1ch, SMART not supported, Up to 40MB/s of syncronous transfer support, Connector: half-pitch 68pin for external SCSI device, half-pitch 50/68pin for internal SCSI device. To connect with GP5MS621A, GP5UR1DC2 or external SCSI devices *SCSI cable is required SCSI Card GP5-123 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Ultrawide, differential-end, x1ch, SMART not supported, Up to 40MB/s of syncronous transfer support, Connector:half-pitch 68pin for external SCSI device, half-pitch 50/68pin for internal SCSI device For connection with Disk Array devices *SCSI cable is required SCSI Card GP5-125 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Ultrawide, SE, x1ch, SMART supported, Up to 40MB/s of syncronous transfer support, Connector:half-pitch 68pin for external SCSI device, half-pitch 50/68pin for internal SCSI device. For connection with internal and external SCSI devices *SCSI cable is required SCSI Card GP5-126 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Ultra2wide, LVD, x1ch, SMART supported, Up to 80MB/s of syncronous transfer support, Connector:half-pitch 68pin for external SCSI divece, half-pitch 50/68pin for internal SCSI device. For connection with internal and external SCSI devices *SCSI cable is required RAID Card GP5U141 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ RAID card, Ultrawide SCSI, SE, x2ch, 16MB cache, RAID level 0,1,5 are supported, For internal/external array configuration *SCSI cable(for array configuration use)is reauired RAID Card GP5U142 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ RAID card, Ultrawide SCSI, SE, x2ch, 4MB cache, RAID level 0,1,5 are supported, For internal array configuration *SCSI cable(for array configuration use)is required RAID Card GP5-143 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ RAID card, Ultrawide SCSI, x2ch, 8MB cache, RAID level 0,1,5 are supported, For internal array configuration *SCSI cable(for array configuration use) is required RAID Card GP5-144 RAID card, Ultra2wide SCSI, LVD, x3ch, 32MB cache, RAID level 0,1,5 are ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ supported, For internal/external array configuration *SCSI cable(for array configuration use) is required SCSI Cable GP5U831 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Connection internal devices (0.7m) for C8xxi SCSI Cable GP5S-832 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ For connection GP5-144 to GP5UR1DC3 SCSI Cable GP5-837 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Internal SCSI HDD connection(68pin) for C3xxi SCSI Cable GP5-838 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Internal narrow SCSI cable for 5'' Bay (50pin) for C3xxi SCSI Cable GP5MU823A ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ SCSI-3(68pin)-SCSI-4(68pin), For connecting GP5U121/125 to GP5MS621A, GP5UR1DC2 / GP5-126 to GP5UR1DC3(3.0m) SCSI Cable GP5MU829A - - - - - - - - - - - - - - - - - - For connection between GP5U141 and GP5MS621A (2.0m) SCSI Cable GP5MU830A - - - - - - - - - - - - - - - - - - For connection GP5U141 to GP5MS621A /GP5U141 to GP5UR1DC2 (3.0m) A cable is required in 1ch 29 teamserver Hardware SCSI Cable C300i C310i C320i C810i C820i C850i C870i G820i G850i L840i G870i L850i M840i M850i M850ic M860i Produt ID M851i Product M861i Models GP5MU831A - - - - - - - - - - - - - - - - - - Remarks SCSI-4(68pin)-SCSI-4(68pin) ,For connecting each Hard Disk Cabinet (GP5MS621A), (0.3m) SCSI Cable GP5U832 - - - - - - - - - - - - - - - - - - For connection between SCSI Card and external SCSI device (full pitch-50pin),(1.0m) SCSI Cable GP5U833 - - - - - - - - - - - - - - - - - - For connection between SCSI Card and external SCSI device (half pitch50pin),(1.0m) SCSI Cable GP5U834 - - - - - - - - - - - - - - - - - - For connection between SCSI Card and external SCSI device (half pitch68pin),(1.5m) LAN Card GP5-182 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 100BASE-TX/10BASE-T, PCI-bus, driver is included Twisted pair cable (category 5:100BASE-TX/category3:10BASE-T) is required LAN Card GP5-183 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ GIGA bit LAN Card supports 1000BASE-SX optical fiber cables, compatible with both 64-bit and 32-bit PCI slots.Driver is included, a Fibre channel Cable (GP5311:2m, GP5-312:5m, GP5-313:15m) is required. Server Monitor Module GP5USM102 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ SMM has its own CPU,LAN,and power supply(AC adapter, option). External Interface:10BASE-T RJ45/RS232C D-sub 9pin, AC adapter:16V(DC) *Modem-only operation is impossible 30 MEMO 31 Specifications are subject to change without notice. For the latest detailed information, contact your local representative. All brand names and product names are trademarks and registered trademarks of their respective holders. C1999 Fujitsu Limited. All rights reserved. Printed in Japan. Third Edition February 1999 FUJITSU LIMITED Business Development & Marketing Division Marketing Group Marunouchi Center Building 6-1, Marunouchi 1-chome, Chiyoda-ku, Tokyo 100-8211, Japan Phone: +81-3-3215-5255 Fax: +81-3-3215-5259 URL http://www.fujitsu.co.jp/index-e.html BK0065-3NS 32