Preview only show first 10 pages with watermark. For full document please download

Service Information Hotpoint Side-by-side Fridge

   EMBED


Share

Transcript

5407399 Issue 2 March 2011 HOTPOINT SIDE-BY-SIDE FRIDGE FREEZERS (7 ~ Segment Version) Models Covered Comm. Code Energy Band 'A' Models MSZ801DF 48862 MSZ802DF 46196 MSZ803DF 48863 MSZ806DF 57217 Service Information Indesit Company UK Ltd © 2011 Reg. Office: Peterborough PE2 9JB Registered in London: 106725 Indesit Company HEALTH AND SAFETY For the servicing of refrigeration products, containing R134a refrigerant. These instructions are in addition to any other Company procedures already published. Published primarily for Indesit Company engineers working in the UK or Southern Ireland, for which these instructions are MANDATORY. General 1. This manual is not intended as a comprehensive repair/maintenance guide to the appliance. 2. It should only be used by suitably qualified persons having technical competence, applicable product knowledge, suitable tools and test equipment. 3. Servicing of electrical appliances must be undertaken with the appliance disconnected. (unplugged from the electrical supply). 4. Servicing must be preceded by earth continuity and insulation checks. 5. Personal safety precautions must be taken to protect against accidents caused by sharp edges on metal and plastic parts. 6. After servicing, the appliance must be rechecked for electrical safety. Refrigerant R134a - Safe Handling - Transporting & Storage 1. Work areas should be well ventilated and any immediate heat sources turned off. 2. Do not smoke where there is a possibility of refrigerant in the atmosphere. Customer/s should also be advised. 3. Cylinders must not have heat applied, or stand close to a heat source, and should be stored out of direct sunlight. 4. Should a sudden release of refrigerant occur, open windows or outside doors in the immediate vicinity, then evacuate for a few minutes. 5. It is illegal to intentionally vent R134a refrigerant to atmosphere. Follow the company procedure on collection and reclamation. 6. If a leak is identified the appliance must be repaired immediately if possible. 7. Where it is not possible to repair the appliance immediately the customer should be advised: Appliance should be turned off and the refrigerant recovered. 8. Returned compressors must be sealed to prevent the escape of oil and refrigerant. Refer to the Environmental responsibilities for service engineers in your Health and Safety booklet. 9. Cylinders (R134a) being transported must be in an upright position on the floor of the vehicle and prevented from movement. 10. A green compressed gas label Part No. 8100062 should be displayed on the rear of the vehicle. Service Manual UK English 2 of 37 Indesit Company CONTENTS Health & Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Index & Serial Number / Product Identity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 6 Appliance Dimensions & Water Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Detailed View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Control Panel Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 - 10 Description of Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Component Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 - 13 Temperature Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Alarm Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Auto-Test and Fault Conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 - 17 Air Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 - 19 Ice-Maker Function and Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Power Module Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 - 22 Servicing & Dismantling Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 - 26 Compressor Connection Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Power Module Edge Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Connector Block Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Theoretical Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Thermistor Sensor Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 - 36 PRODUCT IDENTITY Example 1 Industrial Code: 8539 695 15000 2 Serial Number: Printed on a separate label below the Rating Plate Build number that day, e.g. 1421th built Day of manufacture, e.g. 03rd of month 705031421 Month of manufacture, e.g. May Year of manufacture, e.g. 2007 1 2 Service Manual UK English 3 of 37 Indesit Company MODEL INTRODUCTION The models included in this publication are 1765 mm high Side by Side no-frost Fridge Freezers that were introduced in July 2007. All models are similar with regard to the furniture design, but there are variations for exterior colour. Models MSZ801DF, MSZ802DF, MSZ803DF and MSZ806DF interior: The interior of the fridge has safety glass shelves, one meat drawer (chiller) and one humidity controlled salad bin (crisper) with a glass cover. The door has two deep shelf, dairy shelf with a lid, a commodity shelf and lower bottle shelf. The interior of the freezer section has two drawers of varying sizes, two safety glass shelves of varying sizes and ice cube maker. The door has four commodity shelves of varying sizes. For banding and colour information, refer to the Front Cover and or Specifications page. The appliance is “no-frost” design so defrosting is automatic. All models have wheels at the rear and wheels / adjustable feet at the front. The digital display interface module (7 ~ segment LED) is mounted in the front of the freezer door with the drinks dispenser, the fast freeze button and ice maker controls are also mounted in the same area. The fridge and freezer temperature settings are adjusted by selecting the + / - buttons next to the relevant temperature display window. All functions are monitored and actioned by the power module mounted at the rear of the appliance within the compressor compartment. The climate class is N / ST signifying that it is designed to operate in ambient temperatures between +16°C to +38°C. As with many refrigeration appliances, it is important that it is installed and operated within the recommended ambient temperature range and that there is adequate ventilation. All appliances equipped with an automatic ice-maker and water dispenser must be connected to a water supply that only delivers drinking water. See specification page for pressure requirements. Service Manual UK English 4 of 37 Indesit Company SPECIFICATIONS Colours Polar White Silver Stainless Steel Black June 2007 Introduction Date July 2007 July 2008 MSZ801DF MSZ802DF MSZ803DF MSZ806DF Suffix 'DF' = dispenser models GENERAL: Manufactured in: Italy Appliance Type: Side by Side Static / No- Frost: No-Frost Door Hinging - Freezer L/H & Fridge R/H Reversible: No Plug/Cable: UK / 1.6m Water Pipe: 1.65m Noise Level: 'A' band models ~ 45dB Climate Class: (Rating Plate) Refrigeration Type: N.ST = 16°C to 38°C No-Frost - Fin On Tube (FOT) DIMENSIONS & WEIGHT: Height: 1774 mm Width: 902 mm Depth: 752 mm To allow product handling and sufficient air circulation, leave at least 10 mm clearance at the sides, above the appliance and between the rear panel and the wall. Weight Gross: 146 kg Weight Net: 140 kg CAPACITIES / VOLUME: Fridge: Freezer: Freezing Capacities 24 hrs Conservation Time Gross Volume 340 litre 206 litre Net Volume 335 litre 155 litre 12 kg 5 hours Service Manual UK English 5 of 37 Indesit Company TECHNICAL DATA: Power Supply Voltage: 220/240 V Power Supply Frequency: 50 Hz Mains Water Supply: Min. 1.7 bar Max. 8.1 bar Freezer Lamp: E27 40W 220V - 240V Dispenser Lamp: E14 10W 230 - 240V Fridge Lamp (Blue Light): T-Click 40W 220V - 240V ENERGY Energy Class: A Power Consumption: 1.39 kWh/24hr Annual Consumption: 507.3 kWh/yr COMPRESSOR WINDING Manufacturer: Embraco Type I/D: EGYS 90 HLP Winding Resistance Start: Run: 21.3 : 12.3 : Refrigerant/ Grams: R134a / 160g - Refer to the appliance rating plate Insulation: C-Pentane HEATER RESISTANCES Evaporator Defrost Heater: 8.57 k: COMPONENT RESISTANCES Condenser Fan Motor: 4.49k: Evaporator Fan Motor: 2.35k: Water Dispenser Solenoid Valve: 8.68k: Water Ice Maker Solenoid Valve: 8.71k: Service Manual UK English 6 of 37 Indesit Company APPLIANCE DIMENSIONS (all measurements are approximate) APERTURE MEASUREMENTS PLAN VIEW (WITH DOORS OPEN 90° AND FULLY) Cabinet Height = 1760 mm Cabinet Height with doors = 1765 mm Depth including door handles: 605 mm + 150 mm = 750 mm Depth without doors = 605 mm Depth without handles: 605 mm + 110 mm = 715 mm WATER FILTER 1. Locate the water filter cartridge cap below the freezer compartment door. Rotate the cap counter clockwise to a vertical position and pull the cap and filter cartridge out through the base grille. Note: Since there is water in the cartridge, some spilling may occur. 2. Remove the cartridge cap by sliding it off the end of the old cartridge. DO NOT DISCARD THE CAP. 3. Take the new cartridge out of its packaging and remove the protective cover from the o-rings. Make a note of the installation date in the space provided on the new cartridge. 4. Slide the cartridge cap onto the new cartridge. 5. With the cartridge cap in the vertical position, push the new filter cartridge into the base grille until it stops. Rotate the cartridge cap clockwise to a horizontal position. 6. RUN WATER THROUGH THE DISPENSER UNTIL THE WATER RUNS CLEAR (about 9-14 litres or 6-7 minutes). This will clean the system and clear air from the lines. Note: As air is cleared from the system, water may spurt out of the dispenser. Service Manual UK English 7 of 37 Indesit Company DETAILED VIEW R N T D A C I S O J B* S K L QPM F H E FG REFRIGERATOR COMPARTMENT A. Inside light B*. Inside light (not fitted) C. Adjustable shelf D. Shelf - drawer lid E Crisper (Salad Bin) F. Crisper adjustment (Humidity Control) G. Meat / vegetable drawer (Chiller) H. Meat / vegetable drawer adjustment I. Dairy products compartment J. Door trays K. 2-litre door tray with bottle holder L. 0.75 litre door tray M. Water filter FREEZER COMPARTMENT N. Automatic ice-maker O. Glass shelves / Racks (depending on the model) P. Drawer / Bottom basket (depending on the model) Q. Drawer / Top basket (depending on the model) R. Ice cube drawer S. Freezer door trays T. Inside light Service Manual UK English 8 of 37 Indesit Company CONTROL PANEL INTERFACE TEMPERATURE CONTROL PANEL D E A C B F G BUTTON A DESCRIPTION Freezer temperature adjust / select FUNCTION ~ This function allows you to adjust the displayed temperature. To adjust the temperature press the relevant + / - button until the required freezer temperature is displayed on the left. B Super freeze ~ This function activates the super freeze (fast freeze) so fresh food can be frozen. To enable press until the super freeze symbol appears on the Display. It will automatically disable after 48 hours or when the button is pressed again. C Stand-by function ~ This function turns off the refrigerator and freezer compartments to enable press and hold for 3 seconds: the display will go out and a dash will appear on the left display. To disable press and hold for 3 seconds: the display will return to the previous set temperatures. D Reset ~ This function can be used in the event of an alarm when an acoustic signal and relevant indicator lights are activated. To disable the acoustic alarm signal press the reset button. E Fridge temperature adjust / select ~ This function allows you to adjust the displayed temperature. To adjust the temperature press the relevant + / - button until the required fridge temperature is displayed on the right. F Holiday function ~ This function allows the fridge compartment to be deactivated if the user is going away for sometime, the fridge will maintain adequate temperature for preventing the formation of odours, therefore not necessary to switch the appliance off. B+F Control panel Lock function (Child lock) ~ This function locks the fridge and freezer controls. To lock press and hold both the super freeze and super cool buttons simultaneously for 3 seconds until the lock symbol appears in the display and is accompanied by an acoustic signal. Service Manual UK English 9 of 37 Indesit Company CONTROL PANEL INTERFACE ICE & DISPENSER CONTROL PANEL H J K L BUTTON G DESCRIPTION Dispenser light FUNCTION ~ This function switches on the dispenser light. To enable / disable press the button. H Stand-by function ~ This function turns off the ice maker. To enable the ice maker press and hold until the ice or crushed ice symbol is displayed. To disable the ice maker press and hold until the ice or crushed ice symbol is extinguished. J Ice mode function ~ This function allows you to select between ice cubes or crushed ice to be dispensed. K Reset ~ This function resets the water filter replacement time. Normally the water filter symbol is Green (Blue on some models). = Water Filter OK (Blue on some models) = Water Filter requires replacing soon. = Water Filter needs replacing. L Ice maker lock ~ This function locks the ice maker and water dispenser controls. To lock press and hold for 3 seconds until the lock symbol appears in the display and is accompanied by an acoustic signal. To unlock press and hold for 3 seconds until the symbol is extinguished. Service Manual UK English 10 of 37 Indesit Company DESCRIPTION OF FUNCTIONS Super freeze function ~ This enables and controls the compressor, condenser fan and evaporator fan to cool down the freezer compartment independently of the temperature settings set by the user. The super freeze function will end automatically after 48 hours after activation. Freezer Temperature ~ This can be adjusted and selected by the “+ / -“ buttons in the freezer section of the control interface. For each press of the relevant button you will increase / decrease the temperature setting by 1°C increments. The range is from -18°C (-17°C some models) to -24°C. Freezer Door Alarm ~ The door alarm symbol lights up and the acoustic alarm is activated when the freezer door remains open. When the door is left open for more than 2 minutes, the symbol flashes and an acoustic signal sounds. Fridge Door Alarm ~ The door alarm symbol lights up and the acoustic alarm is activated when the fridge door remains open. When the door is left open for more than 2 minutes, the symbol flashes and an acoustic signal sounds. Fridge Temperature ~ This can be adjusted and selected by the “+ / -“ buttons in the fridge section of the control interface. For each press of the relevant button you will increase / decrease the temperature setting by 1°C increments. The range is from +2°C to +6°C. Holiday Function ~ This enables and controls the fridge damper (baffle) and evaporator fan for the holiday mode. The evaporator fan is activated and the fridge damper (baffle) is opened for only 2 minutes. This process is repeated every 30 minutes while the holiday function is enabled. Service Manual UK English 11 of 37 Indesit Company COMPONENT FUNCTIONS General Information The power module is made up of a number of smaller individual modules (sections), each one controlling a functional component. The modules are linked together when required to control a particular function or functions. The linking of the individual modules is optional and therefore allows for each module to be switched ON or OFF, this is determined from the data stored or collected by the modules and the results of module comparisons. The power module memory stores information such as temperatures and times. Having individual set of parameter values built in to it, directly aimed at providing the specific control needs for the physical and system characteristics of the model type. Fridge & Freezer Control The power module monitors the fridge and freezer air sensors, comparing their sensor resistance values with the cut-in and cut-out parameter values stored in its memory. Although the parameters are set, they allow for adjustment within those parameters so that the user has control. The results from the comparisons will determine if cooling is initiated, other circuits of the module will also use the results. The power module will enable normal operation provided there is no malfunction condition. Fridge or Freezer Malfunction Module The fridge or freezer malfunction module enables the appliance to continue operating in the unlikely hood of the fridge or freezer sensors failing. Pre-set timed functions stored in the modules memory is used to cycle cold request on and off. A malfunction occurs when the fridge or freezer cabinet sensors return a value to the module of either Open or Closed circuit, rather than a particular resistance value. Evaporator Fan Module The freezer fan is located above the evaporator coil and is designed to distribute the cold air produced by the evaporator coil uniformly inside the freezer compartment and when necessary in the fridge compartment. The freezer fan is managed by the module and is switched on/off after a preset time interval that is parameterised in the modules memory after a compressor start/stop. The fan will not operate when in the defrost cycle. After the defrost cycle the fan starts after a timed interval following a compressor start, this interval is also parameterised in the modules memory; this interval is different from the interval programmed for normal operating conditions. Electronic Motorised Damper Assembly (Baffle) The purpose of the damper is to allow the cold air produced by the evaporator to be distributed inside the refrigerator compartment. The damper is located in the top left hand (SX) corner of the fridge compartment. It is controlled by a fridge air sensor (thermistor) positioned in the centre of the rear wall of the fridge. Cold air from the evaporator is distributed in the refrigerator compartment. continued..... Service Manual UK English 12 of 37 Indesit Company COMPONENT FUNCTIONS Compressor The compressor is managed by the power module and switches on whenever a demand for cooling is received. There are situations of cooling demand in which the compressor remains off. These are as follows: 1. 2. Compressor protection: the compressor switches on once a minimum safety time lag has elapsed since the last power-off, thereby allowing the refrigerant gas pressure to reach a point of equilibrium in the refrigerant circuit. The same minimum safety time is observed in the event of a mains power interruption (voluntary or involuntary). This compressor protection strategy is observed only after the product has been operating continuously for the number of hours defined in the module memory. Pause after defrost: at the end of the defrost cycle the compressor observes a protection time parameterised in the module memory so that the water formed during the defrost can be completely drained. Service Manual UK English 13 of 37 Indesit Company TEMPERATURE TABLES ON - OFF DAMPER TEMPERATURE TABLE Refrigerator Display 6 5 4 3 2 Any of the above REFRIGERATOR Temperature Sensor Damper (Baffle) ON (°C) Damper (Baffle) OFF (°C) 7.5 5.5 6.5 4.5 5.0 3.5 4.0 2.5 3.0 1.5 Super Cool 3.0 1.5 FREEZER CONTROL TABLE Freezer Display -17 -18 -19 -20 -21 -22 -23 -24 Any of the above FREEZER Temperature Sensor Compressor ON (°C) Compressor OFF (°C) -17 -19 -18 -20 -19 -21 -20 -22 -21.5 -23.5 -22.5 -24.5 -23.5 -25.5 -24.5 -26.5 Super Freeze Continuous Run Service Manual UK English 14 of 37 Indesit Company ALARM CONDITIONS Control Panel Interface (mounted above dispenser assembly) Example above shows the ALARM 'd' flashing in the fridge temperature display. • Check fridge Air Baffle (Damper) / Connections. TEMPERATURE DISPLAY Freezer Fridge C -- -9°C or warmer CF C d ICON DISPLAY Cubed Ice Crushed Ice ALARM CONDITION Check freezer sensor / connections. Freezer too warm usually shown when turned on for the first time *. Temperature reached during a power cut *. Communication alarm between the control and display module. Check connections to both modules. Note: The appliance will run on default settings until fault is rectified. Check fridge sensor / connections. Check fridge air baffle (damper) / connections. ALARM CONDITION Check fill valve ice maker solenoid and connections. * If the food has thawed out, it MUST NOT be refrozen. To turn the acoustic buzzer off during an alarm condition, press the reset button 'D' once. To restore the alarm condition back to normal operation proceed as follows: 1. 2. 3. Press the main RESET button (D). Remove from the mains power. Reconnect the main power. Service Manual UK English 15 of 37 Indesit Company AUTO TEST This helps with a quick check of the loads and sensors (thermistors), which otherwise are difficult to activate. NOTE: - Before using the AUTO-TEST it is advisable to check the correct operation of the temperature 7-segment LEDs (both fridge and freezer display), which are used for signalling possible malfunctions. Ensure the Super Freeze or Holiday modes have not been selected before starting the AUTO-TEST. TO ACTIVATE TO DEACTIVATE STEP 1: If the appliance has been connected to the mains power for more than 15 minutes, disconnect it and wait 40 seconds before reconnecting it back to the mains supply. SIDE X SIDE NO-FROST MODELS MSZ801DF (cc48862) MSZ802DF (cc46196) MSZ803DF (cc48863) MSZ806DF (cc57217) Sequence Code 06: (3 seconds) Fridge Sensor, Sequence Code 05: (3 seconds) Freezer Sensor, Sequence Code 04: (3 seconds) Evaporator Fan, STEP 2: Wait until the display completes its Manually: set-up and returns to normal Switching OFF the operation. power supply to the appliance. STEP 3: Open the freezer door. STEP 4: Press the freezer light switch 3 times within 10 seconds. STEP 5: The test is activated when sequence '07' appears in the freezer temperature display. Sequence of check codes is indicated in the Freezer display (Sequence Duration) Sequence Code 07: (3 seconds) Evaporator Defrost Heater, Sequence Code 02 to 00 flashing alternatively: (2.5 minutes) Baffle/damper triac Q3, Sequence Code 09: (3 seconds) Water Valve (Ice Maker), Sequence Code 12 to 00 flashing alternatively: (60 seconds) Ice Maker, Sequence Code 01 to 00 flashing alternatively: Water Valve (Washer Dispenser), NOTE: Confirm by pressing ice water dispenser pedal, Sequence Code 00: END. NOTE: Auto Test needs to be deactivated manually. See previous column. Service Manual UK English 16 of 37 Indesit Company Control Panel Interface (mounted above dispenser assembly) Example above shows Sequence '07' of the Auto Test in the freezer temperature display and fault code '7' to '0' flashing alternatively in the fridge temperature display. • Check evaporator heater / connections. Fault conditions: are signalled to the engineer during Auto Test. See chart below for AUTO TEST fault codes and explanations. TEMPERATURE DISPLAY AUTO-TEST FAULT CODE (explanations) Fridge 8 to 0 flashing alternatively Relay K008 on module faulty (for Damper) 7 to 0 flashing alternatively Evaporator Defrost Heater - resistance can be obtained from power module 12PIN block term 1 & 16PIN block term 1 6 to 0 flashing alternatively Fridge Sensor (thermistor) 5 to 0 flashing alternatively Freezer Sensor (thermistor) 4 to 0 flashing alternatively Evaporator Fan 3 to 0 flashing alternatively Condenser Fan 2 to 0 flashing alternatively Damper (baffle) 9 to 0 flashing alternatively Water Valve for Icemaker H to 0 flashing alternatively Icemaker (Sankyo) 1 to 0 flashing alternatively Water Valve for Water Dispenser Note: If two or more fault codes have been recognised, they will display alternately at 1 second intervals. Service Manual UK English 17 of 37 Indesit Company AIR FLOW COMPRESSOR AND CONDENSER COMPARTMENT The condenser fan is mounted at the rear near the compressor and draws air from the room through the right side of the front lower grille (A), through the condenser (B), around the compressor (C) where it exits out of the rear panel (D) but mainly passes over the dissipator to evaporate the defrost water (E) and finally exits out through the left side of the front lower grille. See image below: C D B E A THE ABOVE PROCESS IS REPEATED SO LONG AS THE CONDENSER FAN IS RUNNING. Service Manual UK English 18 of 37 Indesit Company AIR FLOW FRIDGE AND FREEZER INTERIOR COMPARTMENTS FREEZER The freezer evaporator is mounted just above the evaporator assembly (F). The fan draws air up through the evaporator where it is cooled (G) and blows into the top duct panel where it is channelled out through outlet ports (H). The air circulates around the freezer and returns through lower grille (J) and is drawn back up through the evaporator where the process is repeated. FRIDGE When there is a demand for cooling in the fridge, the damper (baffle) opens allowing cooled air from the freezer to enter via a ducting in the top left of the fridge (K). The air circulates around the fridge and returns to the freezer through the lower ducting (L). This process is repeated so long as the fridge damper is in the open position. MEAT / VEGETABLE DRAWER TEMPERATURE CONTROL SLIDER The cold air is conveyed inside the meat drawer through an adjustable opening between the fridge compartment and the freezer compartment. In this way the temperature inside the meat drawer is kept lower than the rest of the fridge. H K F G J L Service Manual UK English 19 of 37 Indesit Company THE SANKYO ICEMAKER HOW THE ICEMAKER WORKS • Water is automatically measured into the icemaker mould by the inlet solenoid water valve. • The Bi-metal thermostat mounted between the support housing and the mould detects the water / ice temperature. • When the ice is cooled down to about - 9°C the thermostat switches the icemaker motor and the icemaker heater ON. • The motor and the ejector blades begin to rotate. • Because the ice is frozen hard in the mould the motor will stall the ejector blades as they apply pressure on the ice. • During the stall period the heater warms the mould to loosen the ice. This may take a few (up to five) minutes. • When the ice is loose enough, the ejector blades and the motor will complete the rotation and eject the ice from the mould. • The ice collects in the ice bucket below the icemaker. • The water inlet valve solenoid switches on again, to fill the mould with fresh water. NOTE: The Icemaker can only be checked with the 'Built-In Auto Test routine', see page 16. Service Manual UK English 20 of 37 Indesit Company POWER MODULE Parameters Parameter Values Stored in the Module Memory Direct the Appliance Operations - Parameters set in the module memory control the appliance functions. The minimum and maximum values for temperature are preset in the module memory. Sensors monitor temperature and the values are registered in the module. Where the sensor values are outside the presets a particular function will start or stop. Where a sensor fails, open or closed, the appliance operation will be controlled by time. The timed values for this are calculated in the module memory. The power module monitors door opening times and compressor run times. When the total of the door open and compressor run times are equal to or exceed the parameter values set in the memory, a defrost sequence will be initiated. COMPRESSOR OPERATION Compressor Operation There are situations of cooling demand in which the compressor remains off. These are as follows: Compressor protection: the compressor switches on once a minimum safety time lag has elapsed since the last power-off, thereby allowing refrigerant gas pressure to reach a point of equilibrium in the refrigerant circuit. The same minimum safety time is observed in the event of a mains power interruption (voluntary or involuntary). Approximately 7 minutes • Pause after defrost: at the end of the defrost cycle the compressor observes a protection time parameterised in the module memory so that the water formed during defrost can be completely drained. Approximately 7 minutes Service Manual UK English 21 of 37 Indesit Company POWER MODULE Parameters DEFROST HEATING ELEMENTS Defrost Heating Elements The parameters utilised to start the defrost cycle are as follows: The parameters utilised to end the defrost cycle are as follows: • Compressor ON time since the last defrost cycle. 8 hours, but the start time will reduce dependant on door opening times. • The appliance is plugged in and switched on. • Total time since the last defrost cycle. 50 hours, but the start time will reduce dependant on door opening times. • Maximum time defrost heater is ON. Approximately 20 minutes Defrost end temperature (freezer defrost cut-out). +7°C ± 3°C FREEZER FAN OPERATION Freezer Fan Operation The freezer fan is managed by the power module and is switched on/off after a preset time interval that is parameterised in the memory after a compressor start/stop. After the defrost cycle the fan starts after a timed interval following a compressor start, also this interval is parameterised in the memory; Compressor 7 minutes PLUS 3 minutes for the Fan = 10 minutes Service Manual UK English 22 of 37 Indesit Company SERVICING & DISMANTLING INSTRUCTIONS Before commencing any work refer to the Safety Notes at the beginning of this manual. All necessary precautions must be taken to prevent damage to the premises and the appliance. The appliance must be disconnected from the mains electricity supply. Where necessary, food and containers should be removed and stored according to the customer’s requirements. A. 1. 2. 3. 4. 5. 6. FREEZER DOOR REMOVAL Remove the lower plinth/grille (2 screws). Disconnect the water tube that enters the bottom of the freezer door from the in-line connector. Remove the top hinge cover (1 hex head screw). Disconnect the 6-pin and 2-pin wiring connectors. Remove 3 hex head screws securing the hinge, whilst supporting the door. Ease the door from the cabinet and lift from the lower hinge without damaging the water tube. B. 1. 2. 3. 4. FRIDGE DOOR REMOVAL Remove the lower plinth/grille (2 screws). Remove the top hinge cover (1 hex head screw). Remove 3 hex head screws securing the hinge, whilst supporting the door. Ease the door from the cabinet and lift from the lower hinge. C. 1. 2. 3. 4. DOOR ALIGNMENT/ADJUSTMENT Remove the top hinge cover (1 hex head screw). Loosen the 3 hex head screws securing the hinge. Adjust the alignment using the small adjustment screw. Tighten the 3 hex head screws to secure the hinge. D. DOOR HANDLES 1. Remove the single screws securing the handle end cap mouldings at each end. 2. Remove the end cap mouldings from the tubular handle grip. These are very tight. E. 1. 2. 3. 4. ICEMAKER Remove the ice cube bin. Remove the one screw on the underside front of the icemaker. Slide the icemaker forward and away from its support cradle. The connector is embedded in the sidewall at the end of the icemaker; access can be gained after removing a black sponge block protecting it. F. 1. 2. AUGER & SOLENOID Remove the ice cube bin and freezer shelving. Remove the 4 screws (1 at each corner) securing the auger motor and solenoid assembly to the side mouldings. Ease the unit forward and reach in to release the connector from the right hand (DX) sidewall. 3. Service Manual UK English 23 of 37 Indesit Company G. FREEZER LAMP COVER & LAMP 1. Squeeze the sides inward and down. The front location tab can then be unhooked from its slot. 2. The lamp has two spade terminations and can be pulled out. H. 1. 2. 3. 4. 5. J. 1. 2. 3. 4. 5. FREEZER REAR PANELS (EVAPORATOR COVERS) Remove the icemaker as in E and its support cradle. Remove the auger and solenoid assembly as in F. Remove all sidewall runners and fittings (except senor probe cover). Note which way up the runners are attached to the sidewall. Remove the top section of the rear panel (2 screws). Remove both lower rear panel sections together (6 screws) to expose the evaporator - (foil insulation behind the sections joins them together). On reassembly, ensure that the foil insulation is stuck down properly. EVAPORATOR FAN MOTOR Remove the components as in E, F, G, and H. Remove the fan blade. Lift the motor to release the front retaining plastic moulding from its location. Release the rear retaining plastic moulding to release the motor completely. Disconnect the 2-pin connector. K. FAN MOTOR (Gain access for testing defrost heater, fan motor and cut-out) 1. Remove the 2 bottom screws of the middle rear panel. 2. Using a chisel knife or similar tool ease the bottom edge of the panel away from the foam pad stuck behind it. 3. Lift the bottom edge forward so the panel is approximately at 45°. 4. Slide the panel forward along the side runners. 5. Disconnect the 2-pin connector for the fan motor. 6. Remove the two screws securing the plastic housing to the rear wall. 7. Lift the assembly from the evaporator metal heat shield. L. 1. 2. 3. 4. EVAPORATOR Remove the components as in E, F, G, H and K. Lift the evaporator metal heat shield upward slightly to release it from the retaining clip on the rear wall. Note: It is important to relocate in the clip properly on reassembly. Disconnect the 6-pin connector above the evaporator and the earth connection to the metal heat shield. Note: Ensure that the earth connection is relocated properly on reassembly. Pull the bottom of the evaporator outward and raise upward to remove the heat shield from the evaporator. Note: 2 metal clips which are not easy to see, hold the heat shield to the bottom run of the evaporator. These can fall out as the heat shield is removed. The metal clips are best refitted as follows: Before refitting the heat shield, locate the 2 clips correctly in their respective positions inside the heat shield, toward the bottom. As the heat shield is pushed into place over the evaporator, the clips should relocate in position on the bottom run of the evaporator tube. continued..... Service Manual UK English 24 of 37 Indesit Company M. 1. 2. 3. 4. DEFROST HEATER (See K for testing purposes) Remove the components as in E, F, G and H. Disconnect the two connections to the heater. Remove the components as in K. Push the heater upward out of its retaining clips, the clips can now be removed completely and the heater withdrawn from the evaporator. N. THERMAL CUT-OUT 1. Remove the components as in K1 to 4, to gain access. Note: The thermal cut-out is supported by a plastic moulding at each side and is located at the top of the evaporator pipe. The plastic moulding must always be positioned in this way. NOTE: The pipe that the cut-out and plastic support is mounted to must be 30 mm above the top fins of the evaporator. P. 1. 2. COMPRESSOR HOUSING COVER PANEL Remove the hex head screw securing the cover. Keep the panel upright and manoeuvre upward to release from two locating plates at the bottom. Note: This can be awkward because the cover has a lip that fits under the rear of the appliance. Q. COMPRESSOR TERMINAL BOX 1. Cover pushes downward to fit. It can be removed by applying pressure in an upward direction at the lower edge of the black cover, just above the cable entry position. 2. Release the cable clamps. 3. Prise the PTC and overload assembly from the compressor. R. 1. 2. 3. 4. SOLENOID VALVES Remove the component as in P above. Located at the rear right hand side (DX). Release 2 screws securing the valve assemblies to a base bracket. Remove the water pipes as necessary. S. 1. 2. PLASTIC EVAPORATION TRAY Remove the components as in P and R above. The tray can now be removed from the rear of the appliance. T. 1. 2. 3. 4. 5. 6. 7. 8. CONDENSER FAN MOTOR Release the 2 screws securing the lower plinth grille beneath the doors. Disconnect the water pipe feeding the in-line connector below the freezer door. Remove the compressor cover as in P above. Release the screw securing the plastic frame of the condenser fan to the back of the appliance. Disconnect the water pipe at the green solenoid. Draw both water pipes through the plastic frame. Disconnect the connections to the motor - This is best done at the module, see page 28. Lay the plastic frame and motor over at the top toward the solenoid valves. Manoeuvre the assembly to remove from the lower brackets and release. Service Manual UK English 25 of 37 Indesit Company U. 1. 2. 3. POWER MODULE Remove the cover as in P. Remove the 2 screws securing the module and cover to the rear right hand edge of the cabinet. Prise the cover from the module box to gain access. V. 7. 8. FRIDGE DAMPER (BAFFLE) WORKING FROM THE FREEZER COMPARTMENT Remove the ice bucket. Remove the 2 screws and remove the top vent. NOTE: the bottom edge of the vent slots behind the rear panel. Pull the shaped duct tube from where it locates in the right hand (DX) duct channel. WORKING FROM THE FRIDGE COMPARTMENT Pull the front cover off the damper housing. This can be tight. Remove the 2 screws and remove the damper housing. Release the damper assembly from the liner by depressing all 4 legs located on the freezer compartment side. Disconnect the wiring from the damper motor. Remove the polystyrene sections from the damper. Check the seals on reassembly. W. 1. 2. 3. CONTROL PANEL INTERFACE Lift the water drain grille from below the dispensing levers and remove the 2 screws. Ease the control panel away from the door at the bottom and lift to remove. Disconnect the edge connectors. X. 1. 2. 3. 4. DISPLAY PCB MODULE Remove the control panel interface as in W above. Remove the 5 x T10 screws securing the cover over the PCB. Remove 1 x T10 screw securing the module. Prise the 2 tabs away to remove the PCB. Y. 1. 2. DISPENSER SWITCHES & LAMP Remove the control panel interface as in W above. Depress or open tabs to remove switches or lamp holder. Lamp 10W SES. Z. 1. 2. 3. 4. DISPENSER LEVERS Remove the control panel interface as in W above. Disconnect the various connectors. Release the 2 screws and remove the white moulding holding the switches and lamp holder. Remove the clear Perspex cover on the ice dispenser lever. This can be helped by gently twisting on the lever to release the hooks from the rear of the lever. Disassemble the damper assembly in the dispenser - i.e. round white object at the top of the dispenser frame toward the right hand side (DX). Remove the hex head screw and spring clip (note small spacer under clip) between the two levers. The long hinge pin can be released from the right hand end only (note the position of a metal spacing washer between the white and brown mouldings on the hinge pin). Using Sniped Nose pliers, grip the right hand (DX) end of the pin and push upward to release. Draw the pin out to the right hand side to release the whole assembly. 1. 2. 3. 4. 5. 6. 5. 6. 7. 8. Service Manual UK English 26 of 37 Indesit Company COMPRESSOR CONNECTION CHART EMBRACO COMPRESSOR TERMINAL BLOCK 1 ~ COMMON (Overload) L ~ LIVE (line) & Capacitor ~ EARTH S ~ CAPACITOR N ~ NEUTRAL SCHEMATIC VIEW OF TERMINAL BLOCK TERMINAL COLOUR 1 BLACK L BROWN N S DESCRIPTION COMMON (OVERLOAD) LIVE & RUN CAPACITOR GREEN/YELLOW EARTH BLUE BLUE NEUTRAL RUN CAPACITOR 1 L S N Service Manual UK English 27 of 37 SOME TERMINALS MAY NOT BE USED, DEPENDING ON THE MODEL Pin 9 ( water valve feedback ) Pin 10 ( DC Fan optional ) Pin 10 ( NC ) Pin 12 ( Freezer door communication RX ) Pin 11 ( Emitter IDI load ) Pin 11 ( Freezer door communication TX ) Pin 12 ( Freezer lamp load ) Pin 10 ( Freezer door UI neutral ) Pin 13 ( Fridge lamp load ) Pin 9 ( NC ) Pin 14 ( Defrost heater load ) Pin 8 ( Evaporator fan load ) Pin 15 ( IMC load ) Pin 7 ( Damper load ) Pin 9 ( Ice maker + ) Pin 8 ( Ice maker - ) Pin 7 ( Ice maker probe ) Pin 6 ( Ice maker probe ) Pin 4 ( Freezer probe ) Pin 16 ( Receiver IDI load ) 28 of 37 Pin 3 ( Condenser fan line ) Pin 3 ( Fridge probe ) 6 4 16 9 12 7 10 6 4 3 3 1 8 1 1 5 1 2 1 6 Pin 2 ( Water valve line ) Pin 1 ( Ice valve line ) Pin 1 ( Fridge probe ) Pin 8 ( IMC water valve return ) Pin 7 ( Fridge lamp feedback ) Pin 1 ( Bimetallic feedback ) Pin 6 ( Freezer lamp feedback ) Pin 2 ( NC ) Pin 5 ( Lamps line ) Pin 3 ( Reciever IDI feedback ) Pin 4 ( Damper line ) Pin 4 ( Motor Load-Neutral ) Pin 3 ( Reciever IDI line ) Pin 5 ( Damper feedback ) English Pin 2 ( Freezer door line ) Pin 1 ( Freezer line ) Pin 6 ( Emitter IDI line ) Pin 2 ( Freezer probe ) Pin 1 ( Ice maker Neutral ) Pin 2 ( Ice maker Hall ) Pin 3 ( Ice maker + 12 VC ) Pin 4 ( Ice maker Test ) Pin 5 ( DC Fan Optional ) Indesit Company Service Manual UK POWER MODULE EDGE CONNECTIONS Indesit Company CONNECTOR BLOCK CHART DISPENSER ASSEMBLY CONTROL PANEL MODULE MICRO SWITCHES ICE DISPENSER HEATER SWITCH 6-PIN CONNECTOR WATER DISPENSER LAMP HOLDER FREEZER DOOR EVAPORATOR FAN & CUT-OUT FRIDGE COMPARTMENT TOP HINGE 6-PIN CONNECTOR DAMPER Service Manual UK English 29 of 37 Indesit Company Service Manual UK THEORETICAL WIRING DIAGRAM 30 of 37 English Indesit Company THERMISTOR (NTC) SENSOR LOCATION Two sensors are used in these models, the approximate position is as follows: 1. 2. Freezer Air Sensor - Located in the left liner wall just below the icemaker. Fridge Air Sensor - Located in the centre of the rear liner wall of the fridge. Temperature (°C) NTC resistance (Ohm) 10 9,5 9 8,5 8 7,5 7 6,5 6 5,5 5 4,5 4 3,5 3 2,5 2 1,5 1 0,5 0 -0,5 -1 -1,5 -2 -2,5 -3 -3,5 -4 -4,5 -5 -5,5 -6 -6,5 -7 -7,5 -8 -8,5 -9 -9,5 -10 -10,5 -11 -11,5 -12 -12,5 5348 5478 5611 5748 5883 6033 6182 6334 6491 6652 6818 6989 7164 7344 7529 7720 7916 8117 8325 8538 8758 8993 9216 9455 9701 9954 10215 10483 10759 11044 11337 11638 11949 12269 12598 12938 13287 13648 14019 14401 14795 15202 15620 16052 16497 16956 Accuracy (± °C) Temperature (°C) NTC resistance (Ohm) 0,6 -13 -13,5 -14 -14,5 -15 -15,5 -16 -16,5 -17 -17,5 -18 -18,5 -19 -19,5 -20 -20,5 -21 -21,5 -22 -22,5 -23 -23,5 -24 -24,5 -25 -25,5 -26 -26,5 -27 -27,5 -28 -28,5 -29 -29,5 -30 -30,5 -31 -31,5 -32 -32,5 -33 -33,5 -34 -34,5 -35 17429 17917 18420 18939 19474 20027 20596 21184 21791 22417 23063 23729 24418 25128 25862 26620 27402 28210 29044 29906 30797 31717 32668 33650 34666 35715 36800 37922 39082 40281 41521 42803 44130 45502 46921 48390 49910 51483 53111 54797 56541 58348 60218 62155 64161 0,6 0,6 0,6 0,6 0,4 0,4 0,4 0,4 0,4 0,4 0,4 0,4 0,4 0,4 0,4 0,6 0,6 0,6 0,6 0,6 0,7 0,7 Service Manual UK Accuracy (± °C) 0,7 0,7 0,7 0,8 0,8 0,8 0,8 0,8 0,9 0,9 0,9 0,9 0,9 1 1 1 1 1 1 1 1 1 1 English 31 of 37 Indesit Company INSTALLATION INSTRUCTIONS INTRODUCTION The model you are installing may differ slightly with respect to some descriptions in this installation, since this covers several models. Install the appliance in a dry and well-ventilated place. Avoid locations in direct sunlight or near a source of heat (oven, heating, etc.). If this cannot be avoided, install the appliance respecting the following minimum distances: Coal or paraffin stoves: 300 mm Electric and/or gas stoves: 30 mm To allow product handling and sufficient air circulation, leave at least 10 mm clearance at the sides, above the appliance, and between the rear panel and the wall. WATER CONNECTION Disconnect the appliance from the mains power supply before starting operations. • The icemaker and water circuit must be connected to a water supply of potable and/or chemically purified water. • The water connection must be carried out in compliance with local regulations. • The appliance is supplied with a water tube, already attached to the back of the product. • Remove the shipping tape from the coiled water tubing on the rear of the appliance. • Connect the transition connector (1) to the household water supply (2). • Make sure that the water tube is not twisted. • The appliance is pre-set for operation at pressures between 1.7 and 8.1 bar (25 and 117 PSI). • Open the water tap. Check for and eliminate any leaks. • The appliance does not require any adjustment or water drain. ELECTRICAL CONNECTIONS Regulations require that the appliance is earthed. The manufacturer declines all liability for injury to persons or animals and for damage to property resulting from failure to observe the prescriptions. Make sure that the installation and the electrical connection are carried out by a qualified technician according to the manufacturer’s instructions and local safety regulations. Ensure that the voltage indicated on the appliance data plate corresponds to the mains voltage. The plug of the appliance must be easily accessible even after installation so that the appliance can be unplugged if necessary. If this is not possible, we recommend the appliance is connected to the mains supply by means of a two-pole switch with minimum break distance between contacts of 3 mm, fitted at an easily accessible point. Do not use extension leads or adapters. After installation, make sure that the appliance is not standing on the power supply cable. Service Manual UK English 32 of 37 Indesit Company INSTALLATION INSTRUCTIONS LEVELLING THE APPLIANCE The refrigerator has two front and two rear wheels at the base of the product on each side that can be adjusted (see Figure A), or four wheels of which only the two front wheels can be adjusted (see Figure B). If the appliance seems unsteady or you want the doors to close easier, adjust the appliance's tilt, following the instructions below (depending on the model, as shown in the figures on the right). Figure A 1. Check the installation location to be sure you have at least 10 mm clearance on all sides including the top. 2. Connect the appliance to the mains power supply. 3. Move the refrigerator into its final position. 4. Open both doors and remove the plinth to locate the levelling bolts at the left and right of the refrigerator base. The top bolt (1) will adjust the rear wheel (if provided), and the bottom bolt (2) will adjust the front wheel. 5. Use the wrench provided to adjust the levelling bolts. Turn the levelling bolt clockwise to raise the appliance, or Figure B anti-clockwise to lower it. It may take several turns of the levelling bolts to adjust the tilt of the refrigerator. Note: do not unscrew the levelling bolts too much when lowering the appliance as they could fall out. Aligning the Doors If, after switching on the appliance and adjusting the refrigerator and freezer doors, the doors are misaligned, disconnect the appliance from the power supply and adjust both doors as indicated in the following diagrams. Service Manual UK English 33 of 37 Indesit Company INSTALLATION INSTRUCTIONS REMOVING THE FREEZER DOOR (A) REMOVING THE REFRIGERATOR DOOR (B) Service Manual UK English 34 of 37 Indesit Company INSTALLATION INSTRUCTIONS MOUNTING THE FREEZER DOOR (C) MOUNTING THE REFRIGERATOR DOOR (D) Service Manual UK English 35 of 37 Indesit Company INSTALLATION INSTRUCTIONS HORIZONTAL ALIGNMENT OF FREEZER AND REFRIGERATOR DOORS (E) VERTICAL ALIGNMENT OF FREEZER AND REFRIGERATOR DOORS (F) Service Manual UK English 36 of 37 Indesit Company Service Manual UK English 37 of 37