Set For Simple I/o Communication Via Devicenet™ In Ip67 Ti

   EMBED


Share

Transcript

Set for Simple I/O Communication via DeviceNet™ in IP67 TI-BL67-DN-S-4 ■ A special software (function module) for integration in PLC systems is not required. ■ Cable max. 50 m between interface and read/write head ■ 3 decimal rotary coding switches to adjust the bus address ■ Maximum transmission rate to the fieldbus 120/250/500 kbps ■ Two males 7/8", 5-pin, for fieldbus connection ■ LEDs for display of supply voltage, group and bus errors as well as status and diagnostics Type designation Ident no. Number of channels Dimensions (W x L x H) Supply voltage max. system supply current I Max. sensor supply I TI-BL67-DN-S-4 1545115 4 140 x 145 x 77.5 mm max. load current I Admissible range 24 VDC 1.5, A 4 A electronically limited current supply electronically limited current supply 8A 11…26 VDC Fieldbus transmission rate Fieldbus address range Fieldbus addressing Service Interface Fieldbus connection technology Voltage supply connection Fieldbus termination 125/250/500 kbps 0...63 2 decimally coded rotary switches RS232 interface (PS/2 socket) 2 × 7/8'', 5-pin from DeviceNet™ cable external Transmission rate Cable length Electrical isolation 115.2 kbps 50 m isolation of electronics and field level via optocouplers Connection technology M12 Sensor supply 0.5 A per channel, short-circuit proof Operating temperature Storage temperature Relative humidity -40…+70 °C -40…+85 °C 5 to 95 % (internal), Level RH-2, no condensation (at 45 °C storage) acc. to EN 61131 mb (5V) sens Edition • 2017-08-24T18:05:09+02:00 o Vibration test Extended vibration resistance Extended vibration resistance - up to 5 g (at 10 to 150 Hz) - up to 20 g (at 10 up to 150 Hz) Shock test Drop and topple Electro-magnetic compatibility Protection class 1/4 VN 02-00 and higher for mounting on DIN rail no drilling according to EN 60715, with end bracket for mounting on base plate or machinery Therefore every second module has to be mounted with two screws each. acc. to IEC 68-2-27 acc. to IEC 68-2-31 and free fall to IEC 68-2-32 acc. to EN 61131-2 IP67 ■ Connection of up to 4 read/write heads via BL ident M12 extension cables ■ Mixed operation of HF and UHF read/ write heads Wiring Diagram DeviceNet™ IN Functional principle The BL ident® system can be installed in many different ways. Various fieldbus standards, such as PROFIBUS-DP, EtherNet/IP, Ethernet Modbus TCP, EtherCAT, DeviceNet, CANopen and PROFINET IO allow flexible integration. BL ident® simple electronic modules (BL20-2RFID-S, BL67-2RFID-S) can be integrated in existing control or host systems without function block, since standard input/output process data is used for communication. Programmable gateways with peripheral preprocessing function relieve the control system and fieldbus level. Preassembled sets (2, 4, 6 or 8-port), easily mounted, available for all fieldbus networks. Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com Set for Simple I/O Communication via DeviceNet™ in IP67 TI-BL67-DN-S-4 Compatible base modules Type Pin configuration BL67-B-2M12 6827186 2 x M12, 5-pole, female, a-coded …/S2500 Connectors …/S2501 Connectors Edition • 2017-08-24T18:05:09+02:00 Connectors …/S2503 2/4 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com Set for Simple I/O Communication via DeviceNet™ in IP67 TI-BL67-DN-S-4 LED display LED D Color RED RED RW0 / RW1 FLASHING (0.5 Hz) OFF ON FLASHING (2 Hz) ON FLASHING (2 Hz) Meaning No error message or diagnostics active. Failure of module bus communication. Check if more than 2 adjacent electronic modules are pulled. Relevant modules are located between gateway and this module. Upcoming module diagnostics No tag, no active diagnostics Tag available Data exchange with tag enabled Read/write head error Short-circuit in the supply line of read/write head Edition • 2017-08-24T18:05:09+02:00 GREEN GREEN RED RED Status OFF ON 3/4 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com Set for Simple I/O Communication via DeviceNet™ in IP67 TI-BL67-DN-S-4 I/O Data Mapping INPUT INPUT Channel 0 Channel 1 OUTPUT Channel 0 Bit 7 Bit 6 Bit 7 Bit 6 DONE BUSY Error Code Error Code 1 Reserved READ DATA (8 Byte) Bit 5 Bit 5 ERROR Bit 4 Bit 3 Bit 4 Bit 3 XCVR CON XCVR ON Bit 2 Bit 2 TP Bit 1 Bit 1 TFR Bit 0 Bit 0 Reserved DONE BUSY Error Code Error Code 1 Reserved READ DATA (8 Byte) ERROR XCVR CON XCVR ON TP TFR Reserved Bit 7 XCVR Reserved Bit 5 TAG ID Bit 4 READ Bit 3 WRITE Bit 2 TAG INFO Byte Count 2 Bit 1 XCVR INFO Byte Count 1 Bit 0 RESET Byte Count 0 2 3 4 5 … 10 11 12 13 Address high byte Address low byte WRITE DATA (8 Byte) TAG ID READ WRITE TAG INFO XCVR INFO RESET Byte Count Byte Count Byte Count 2 1 0 14 15 16 17 … 22 23 Address high byte Address low byte WRITE DATA (8 Byte) XCVR Reserved Bit 6 NEXT NEXT Edition • 2017-08-24T18:05:09+02:00 Channel 1 BYTE BYTE 0 1 2 3 4 5 … 10 11 12 13 14 15 16 17 … 22 23 BYTE 0 1 4/4 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com