Preview only show first 10 pages with watermark. For full document please download

Sf/utp 4x2xawg22/1 Data Cable Lshf / Fire Resistant Ph 120 - B

   EMBED


Share

Transcript

SF/UTP 4X2XAWG22/1 DATA CABLE LSHF / FIRE RESISTANT PH 120 MM www.b-cables.be 41 Data trasmission cables, fire retardant, fire resistant and halogen free Normen / Normes 1 Application Primary (Campus), Secondary (Riser), Tertiary (Horizontal) IEEE 802.3: 10Base-T; 100Base-T; IEEE 802.5 16 MB; ISDN; TPDDI; ATM Circuit integrity structured wiring alarm cable, compatible with all known connection systems to EN 50173, patent protected design, part of intelligent building technology 2 Mechanical properties Bending radius Temperature range without load with load during operation during installation EN 50200 (PH 120 MIN) SA 50267 SD 61034 EN 60332 3 24 ≥ 42 mm ≥ 84 mm -20°C to + 60°C 0°C to + 50°C 3 Flame resistance LSHF: EN 60332 1, EN 61034-2, EN 60754-1/2 LSHF-FR(FRNC): EN 60332 1; EN 60754-1&2; EN 61034-2, EN 60332 3-24; UL 1581 VW 1, BS5839-1 (clause 26.2e); BS8434-2; BSEN 50200, BS4066 part 3, BSEN 20568 4 Electrical properties at 20°C± 5°C Loop resistance ≤ 110 Ω/km Resistance unbalance ≤ 2% Insulation resistance (500 V) ≥ 5000 MΩ*km Mutual capacitance at 800 Hz Nom. nF/km Capacitance unbalance (pair/ground) ≤ 1600 pF/km Characteristic impedance (at 10) MHz (100 ± 15) Ω Nominal velocity of propagation ca. 57 % Test voltage (DC, 1 min) core/core and core/screen 1000 V at 10 MHz 5 mΩ/m Impedance 100 Ohm NVP 67 % INSTALLATION HARMONIZED brochure_2017.indd 41 DATA UTILITIES TEL. & SIGNAL FIRE & SECURITY 1 2 3 4 1. Conductor 2. Insulation 3. Flame protection CONTROL CABLES COAX INDUSTRY AUTOMOTIVE 6 5 4. Drain wire 5. Shield 6. Sheath OTHERS FIBER & TELECOM 8/05/17 10:13