Transcript
SF2-LP01 Small Form Factor Optical Fiber Transceiver 5.0 Volt, PECL, 1300nm LED for Multimode Optical Fiber at up to 200 MBaud
FEATURES
APPLICATIONS
■ MSA SFF 2 x 5 optical fiber transceiver - LC receptacle ■ Optimized for 62.5 or 50/125µ multimode optical fiber ■ Compatible with solder and aqueous wash processes ■ Meets PCI Mezzanine Card max. height requirements ■ Overall metal shield for enhanced EMI performance ■ Full compliance to IEEE, ANSI and ITU requirements ■ Differential PECL inputs and outputs ■ Single +3.3 V power supply
The SF2-LP01 multimode glass optical fiber transceivers provide low profile, cost effective solutions for high datarate multimode (up to 200 Megabaud, up to 2 Km) optical fiber data links with a duplex LC connector interface. These transceivers are fully compliant with IEEE, ITU and ANSI standards but can be used for any other data communications purpose within their operating parameters.
DESCRIPTION
BLOCK DIAGRAM BASELINE REFERENCE
PECL DRIVER RX+ RX-
PIN AND TIA PECL BUFFER SIGNAL DETECT
SD
TXTX+
LEVEL DETECT
PULSE SHAPING
LED
CURRENT AMPLIFIER
L C I N T E R F A C E
The SF2-LP01 fiber optic transceivers consist of transmitter and receiver functions combined in a multisourced 2x5 footprint module. The optical transmitter is a high output 1300nm LED. The transmitter input lines are driven with differential PECL signals applied to the Transmit (TX+ and TX-) pins. These signals are internally converted to a suitable modulation current by a CMOS integrated circuit. The optical receivers consist of PIN and Preamplifier assemblies and CMOS limiting post-amplifier integrated circuits. Outputs from the receivers consist of differential PECL data signals on the Receive (RX+ and RX-) pins and a single ended PECL signal detect function on the Signal Detect (SD) pin.
CASE
1450 Treeland Blvd., S.E., Palm Bay, FL 32909-2211 USA Telephone: 321-308-4100 Fax: 321-308-0434 Web Page: www.stratoslightwave.com
SF2-LP01 Small Form Factor Optical Fiber Transceiver 5.0 Volt, PECL, 1300nm LED for Multimode Optical Fiber at up to 200 MBaud ABSOLUTE MAXIMUM RATINGS Absolute maximum limits mean that no catastrophic damage will occur if the product is subjected to these ratings for short periods, provided each limiting parameter is in isolation and all other parameters have values within the performance specification. It should not be assumed that limiting values of more than one parameter can be applied to the product at the same time.
Parameter Storage Temperature
Symbol
Minimum
TS
-40
Typical
Maximum
Unit
+85
°C °C
Lead Soldering Temperature
TSOLD
+260
Lead Soldering Time
tSOLD
10
Seconds
Supply Voltage
VCC
-0.5
6.0
V
Data Input Voltage
VI
-0.5
VCC
V
Differential Input Voltage (p-p)
VD
2.0
V
Output Current
IO
50
mA
RECOMMENDED OPERATING CONDITIONS Parameter
Symbol
Minimum
Operating Temperature Limit
TA
0
+70
°C
Supply Voltage
VCC
4.75
5.25
V
Data Input Voltage - Low
VIL - VCC
-1.810
-1.475
V
Data Input Voltage - High
VIH - VCC
-1.165
-0.880
V
Data Output Load
RL
Differential Input Voltage (p-p)
VD
Typical
50 0.800
Maximum
Unit
Ohms V
1450 Treeland Blvd., S.E., Palm Bay, FL 32909-2211 USA Telephone: 321-308-4100 Fax: 321-308-0434 Web Page: www.stratoslightwave.com 2
SF2-LP01 Small Form Factor Optical Fiber Transceiver 5.0 Volt, PECL, 1300nm LED for Multimode Optical Fiber at up to 200 MBaud TRANSMITTERS Parameter
Symbol
Baud Rate
Minimum
Typical
Maximum
Unit
10
200
MBaud
-14
dBm
Optical Output Power
PO
-19
Optical Output Wavelength
lOUT
1270
1320
1380
nM
Optical Rise Time (10%-90%)
tR
0.6
1.5
3.0
nS
Optical Fall Time (10%-90%)
tF
0.6
2.0
3.0
nS
Duty Cycle Distortion
tDCD
<0.1
0.6
nS
Data Dependent Jitter
tDDJ
<0.1
0.7
nS
Typical
Maximum
RECEIVERS Parameter
Symbol
Baud Rate
Minimum
Unit
10
200
MBaud
1380
nM
-8.0
dBm
Optical Wavelength
lIN
1270
Optical Sensitivity
PI
-32
-35
Input Duty Cycle Distortion
tDCD
1.0
nS
Input Data Dependent Jitter
tDDJ
0.76
nS
Signal Detect Assert Time
<10
100
µS
Signal Detect Deassert Time
<10
350
µS
1450 Treeland Blvd., S.E., Palm Bay, FL 32909-2211 USA Telephone: 321-308-4100 Fax: 321-308-0434 Web Page: www.stratoslightwave.com 3
SF2-LP01 Small Form Factor Optical Fiber Transceiver 5.0 Volt, PECL, 1300nm LED for Multimode Optical Fiber at up to 200 MBaud
MSA 2x5 SFF TRANSCEIVER PRINTED CIRCUIT BOARD LAYOUT Top View Shown Dimensions Are Shown As:
mm inches
17.78 0.700 7.11 0.280
0.81 +/- 0.1 O 0.032 +/- 0.004 (10) O
1.4 +/- 0.1 0.055 +/- 0.004 (2)
10.16 0.400
9.59 0.378
7.59 0.299
3.0 0.118
13.97 Min. 0.550
3.0 0.118
6.0 0.236
1.78 0.070
3.08 0.121
2.0 0.079
2.0 0.079
CROSS-HATCHED AREAS SHOULD HAVE NO SIGNAL TRACES ON THE TOP LAYER
1450 Treeland Blvd., S.E., Palm Bay, FL 32909-2211 USA Telephone: 321-308-4100 Fax: 321-308-0434 Web Page: www.stratoslightwave.com 4
SF2-LP01 Small Form Factor〈 Optical Fiber Transceiver 5.0 Volt, PECL, 1300nm LED for Multimode Optical Fiber at up to 200 MBaud REGULATORY COMPLIANCE Requirement
Feature
Condition
Notes
MIL-STD-883-3015.7
ESD
Class II
2200V
IEC-801-2
ESD
Human Body Model
25KV
IEC-801-3
EMI
Immunity
10V/M
FCC
EMI
Class B
>20dB
EN 55022 (CISPR 22A)
EMI
Class B
10V/M
IEC-825 Issue 1993-11
Eye Safety
Class 1
TUV Certificate Number R 2171075
FDA CDRH 21-CFR 1040
Eye Safety
Class 1
CDRH Accession Number 9930009
File Number: E209124
EN 60 950 EN 60 825-1 EN 60 825-2
File Number: R 2071075
1450 Treeland Blvd., S.E., Palm Bay, FL 32909-2211 USA Telephone: 321-308-4100 Fax: 321-308-0434 Web Page: www.stratoslightwave.com 5
SF2-LP01 Small Form Factor Optical Fiber Transceiver 5.0 Volt, PECL, 1300nm LED for Multimode Optical Fiber at up to 200 MBaud
2 x 5 MSA SMALL FORM FACTOR TRANSCEIVER PIN NUMBER ASSIGNMENTS TOP VIEW SHOWN
5
4
3
2
1
6
7
8
9
10
MS
RX
TX MS
PIN FUNCTIONS Pin Number
Symbol
MS
MS
Description
Logic Family
Mounting Studs Connect to Chassis Ground
N/A
1
VEERX
Receiver Signal Ground
N/A
2
VCCRX
Receiver Power Supply
N/A
3
SD
Signal Detect Normal Operation: Logic "1" Output Fault Condition: Logic "0" Output
PECL
4
RD–
Receiver DATA Out
PECL
5
RD+
Receiver DATA Out
PECL
6
VCCTX
Transmitter Power Supply
N/A
7
VEETX
Transmitter Signal Ground
N/A
8
N/C
No Connection
N/A
9
TD+
Transmitter DATA In
PECL
10
TD–
Transmitter DATA In
PECL
1450 Treeland Blvd., S.E., Palm Bay, FL 32909-2211 USA Telephone: 321-308-4100 Fax: 321-308-0434 Web Page: www.stratoslightwave.com 6
SF2-LP01 Small Form Factor Optical Fiber Transceiver 5.0 Volt, PECL, 1300nm LED for Multimode Optical Fiber at up to 200 MBaud
TRANSCEIVER APPLICATION SCHEMATIC For Interface To +5.0V PECL Circuits PHY CIRCUIT
TRANSCEIVER
VEETX 7 MS
N/C 8 Z = 50Ω
TD+ 9 PECL
100Ω TD- 10
PECL
Z = 50Ω 130Ω
130Ω
L2
VCCTX 6
VCC = +5.0V C6
C5
C4
L1
VCCRX 2 C2
C3
RD+ 5
Z = 50Ω
RD- 4
Z = 50Ω
PECL
130Ω
C1
100Ω
PECL
130Ω
SD 3 VEERX 1
150Ω
MS
L1, L2 = 1µH to 4.7µH* C1, C2, C6 = 10nF** C3, C4, C5 = 4.7µF to 10µF** * Or ferrite bead alternative ** MLC capacitors
1450 Treeland Blvd., S.E., Palm Bay, FL 32909-2211 USA Telephone: 321-308-4100 Fax: 321-308-0434 Web Page: www.stratoslightwave.com 7
SF2-LP01 Small Form Factor Optical Fiber Transceiver 5.0 Volt, PECL, 1300nm LED for Multimode Optical Fiber at up to 200 MBaud
SMALL FORM FACTOR OUTLINE DIMENSIONS PER 1997 MULTISOURCE AGREEMENT mm Dimensions Are Shown As: inches
13.59 max. 0.535 13.97 Min. 0.550 10.16 0.400
49.56 max. 1.951
Suggested Panel Opening
10.16 0.400
9.55 9.80 0.376 0.386
14.96 0.589
0.46 (10) 0.97 (2) 0.018 0.038 17.78 0.700
7.11 0.280
5.08 0.200 1.78 (8) 0.070
*14.20 0.599 3.17 0.125 (10)
*Single Port Panel Opening Shown Multiple Port Openings: (0.550" x N) + 0.024") N= Number of Ports
IMPORTANT NOTICE Stratos Lightwave, Inc. reserves the right to make changes to or discontinue any optical link product or service identified in this publication, without notice. Stratos Lightwave recommends that its customers to obtain the latest version of the publications to verify, before placing orders, that the information being relied on is current. Stratos Lightwave warrants performance of its optical link products to current specifications in accordance with the Stratos Lightwave standard warranty. Testing and other quality control techniques are utilized to the extent that Stratos Lightwave has determined it to be necessary to support this warranty. Specific testing of all parameters of each optical link product is not necessarily performed on all optical link products. Stratos Lightwave products are not designed for use in life support appliances, devices, or systems where malfunction of a Stratos Lightwave product can reasonably be expected to result in a personal injury. Stratos Lightwave customers using or selling optical link products for use in such applications do so at their own risk and agree to fully indemnify Stratos Lightwave for any damages resulting from such improper use or sale. Stratos Lightwave assumes no liability for Stratos Lightwave applications assistance, customer product design, software performance, or infringement of patents or services described herein. Nor does Stratos Lightwave warrant or represent that a license, either expressed or implied is granted under any patent right, copyright, or intellectual property right , and makes no representations or warranties that these products are free from patent, copyright, or intellectual property rights. Applications that are described herein for any of the optical link products are for illustrative purposes only. Stratos Lightwave makes no representation or warranty that such applications will be suitable for the specified use without further testing or modification.
1450 Treeland Blvd., S.E., Palm Bay, FL 32909-2211 USA Telephone: 321-308-4100 Fax: 321-308-0434 Web Page: www.stratoslightwave.com 8