SFP+ 10G SR Part no: 70287-xx Features Applications  Optical interface compliant to IEEE 802.3ae 10GBASE  10GBASE- at 10.3125Gbps  Electrical interface compliant to SFF-8431  10GBASE- at 9.953Gbps  Hot Pluggable  Other optical links  850nm VCSEL transmitter, PIN photo-detector  Operating case temperature: 0 to 70 °C  Low power consumption  Applicable for 300m MMF connection  All-metal housing for superior EMI performance  Advanced firmware allow customer system encryption information to be stored in transceiver  Cost effective SFP+ solution, enables higher port densities and greater bandwidth Electrical characteristics The following electrical characteristics are defined over the Recommended Operating Environment unless otherwise specified. Parameter Symbol Min. Typical Max Unit Data Rate - 10.3125 - Gbps Power Consumption - 600 800 mW Notes Transmitter Single Ended Output Voltage Tolerance -0.3 - 4.0 V C common mode voltage tolerance 15 - - mV Tx Input Diff Voltage VI 90 350 mV Tx Fault VoL -0.3 0.4 V Data Dependent Input Jitter DDJ 0.10 UI Data Input Total Jitter TJ 0.28 UI 4.0 V 425 mV At 0.7mA Receiver Single Ended Output Voltage Tolerance -0.3 - Rx Output Diff Voltage Vo 150 Rx Output Rise and Fall Time Tr/Tf 30 Total Jitter TJ 0.70 UI Deterministic Jitter DJ 0.42 UI Hexatronic AB Exportgatan 47B SE-422 46 Hisings Backa ps Fax. +46 (0)31-58 59 30 Tel. +46 (0)31-742 53 30 Tel. +46 (0)8-96 76 80 20% to 80% [email protected] www.hexatronic.se SFP+ 10G SR Part no: 70287-xx Optical characteristics The following optical characteristics are defined over the Recommended Operating Environment unless otherwise specified. Unit Values m 2 - 10K Cen ter w avelength (range) nm 1260 -1355 Side Mode Suppression Ratio (min) Operating Reach Transmit Launched power – maximum (Averag e) dB 30 dBm +0.5 – minimum (Average) dBm − OMA dBm -5.2 − OMA-TDP (min ) dBm -6.2 Transmitter an d dispersio n penalty (ma x) Average launch pow er o f OFF transmitte r (max) E xtinction ratio (min) -8 .2 dB 3.2 dBm -30 dB RIN12 OMA (max) Optical Return Loss Tolerance (min) No tes1 3 .5 Notes2 dB/Hz -128 dB 12 nm 1260-1355 Receiver Cen ter w avelength (range) Receive overload (max) in average power1 Receive sensitivity (min) in average power1 dBm 0.5 dBm -14.4 Notes3 Receiver sensitivity (max) in OMA (footnote 2) dBm -12.6 Notes3 Rec eiver R eflec tance (m ax) Stressed receiver sensitivity (max) in OMA2 Vertical eye closure penalty (min)3 dB -12 dBm -10 .3 dB 2.2 Stressed eye jitter (min)2 U Ip -p 0.7 Rec eive elec tric al 3dB upp er cuto ff frequ enc y (max) GH z 12.3 Rec eiver p ow er (damage, Max) dBm 1.5 Notes: 1. 2. 3. The optical power is launched into SMF 31 Measured with a PRBS 2 -1 test [email protected] Measured with a PRBS 2 31-1 test [email protected] BE Hexatronic AB Exportgatan 47B SE-422 46 Hisings Backa Fax. +46 (0)31-58 59 30 Tel. +46 (0)31-742 53 30 Tel. +46 (0)8-96 76 80 [email protected] www.hexatronic.se SFP+ 10G SR Part no: 70287-xx Absolute maximum rating These values represent the damage threshold of the module. Stress in excess of any of the individual Absolute Maximum Ratings can cause immediate catastrophic damage to the module even if all other parameters are within Recommended Operating Conditions. Parameters Symbol Min. Max. Unit Power Supply Voltage V CC 0 +3.6 V Storage Temperature Tc -40 +85 °C Operating Case Temperature Tc 0 +70 °C Relative Humidity RH 5 95 % RX Input Average Power Pmax - 0 dBm Recommended operating environment Recommended Operating Environment specifies parameters for which the electrical and optical characteristics hold unless otherwise noted. Parameter Symbol Min. Typical Max Unit Power Supply Voltage VCC 3.135 3.300 3.465 V Operating Case Temperature TC 0 25 70 °C Hexatronic AB Exportgatan 47B SE-422 46 Hisings Backa Fax. +46 (0)31-58 59 30 Tel. +46 (0)31-742 53 30 Tel. +46 (0)8-96 76 80 [email protected] www.hexatronic.se