Product Datasheet SAOC-10G1F2A
SFP+ Active Optical Cable
Preliminary Features RoHS-6 compliant High speed / high density: support up to 10 Gb/s bi-directional operation Compliant to industrial standard SFP MSA Low power consumption : less than 1.0 W per end Hot-pluggable, light weight cable, small bending radius and distance up to 100 meters facilitate the installation and cable management Reliable VCSEL and PIN photonic devices I2C standard management interface Excellent high speed signal integrity
Description
Application
The SAOC-10G1F2A is a 10Gb/s, hot pluggable active optical cable for Ethernet data transmission. It provides full duplex operation and supports distance up to 100 meters. Each SAOC-10G1F2A is composed of optical transceivers in both ends and multimode fiber cable in between. This integrated optical module solution removes the complicated optical fiber interface and brings friendly and intuitive electrical-to-electrical interface to users.
10G Ethernet Proprietary high speed, high density data transmission. Switch and router high speed backplane interconnect High performance computing, server and data storage.
SAOC-10G1F is designed to meet the requirements of high speed, high density and low power consumption for applications in today’s data centers.
DELTA ELECTRONICS, INC.
1
Revision: S3 5/30/2013
www.deltaww.com
Product Datasheet SAOC-10G1F2A 1. Absolute Maximum Ratings Parameter
Symbol
Min
Storage Temperature Storage Ambient Humidity +3.3V Power Supply
TS HA VCC3
-40 0 0
Typ
Max
Units
85 85 3.6
°C % V
Notes
2. General Operating Characteristics (V CC3=3.135V~3.465V, TC= 10 ºC to 60 ºC, Per End) Parameter
Max
Units
10
60
°C
HA
5
85
%
+3.3V Supply Voltage +3.3V Supply Current Total Power Dissipation
V CC3 IVCC3 PD
3.135
3.465 300 1.0
V mA W
Input Control Voltage- High Input Control Voltage - Low Digital Output Voltage- High Digital Output Voltage- Low
ViH ViL VoH VoL
2.0 -0.3 2.0 0
Vcc+0.3 0.8 Vcc+0.3 0.8
V V
[2] [2] [3] [3]
400
kHz
[4]
Operating Case Temperature Ambient Humidity
Symbol
Min
TC
Typ
Clock Rate-I2C
Notes
[1]
Notes: 1. Non-condensing 2. For all control input pins: TX_DISABLE 3. For all status output pins: RX_LOS, TX_FAULT 4. For management interface.
DELTA ELECTRONICS, INC.
2
Revision: S3 5/30/2013
www.deltaww.com
Product Datasheet SAOC-10G1F2A 3. High Speed Characteristics- Transmitter (V CC3=3.135V~3.465V, TC= 10 ºC to 60 ºC, Per End) Parameter Reference Differential Input Impedance Signal Speed Differential Data Input Swing
Symbol
Min
Typ
Zd Vin_pp
Units
Notes
100
Ω
[1]
10.3125
Gbps mV
[2]
180
Max
600
Notes: 1. AC coupled inside AOC module. 2. Tested with PRBS2^31-1 BER: 10E-12
4. High Speed Characteristics- Receiver (V CC3=3.135V~3.465V, TC= 10 ºC to 60 ºC, Per End) Parameter Reference Differential Input Impedance Signal Speed Differential Data Output Swing Differential Data Output Swing When Squelched Rise / Fall Time (20% ~80%)
Symbol
Min
Typ
Zd 150
24
Max
Units
Notes
100
Ω
[1]
10.3125
[2]
850
Gbps mV
50
mV ps
Notes: 1. AC coupled inside AOC module. 2. Tested with PRBS2^31-1 BER: 10E-12
DELTA ELECTRONICS, INC.
3
Revision: S3 5/30/2013
www.deltaww.com
Product Datasheet SAOC-10G1F2A 5. Pin Description
SFP+ Transceiver Electrical Pad Layout
6. Module Electrical Pin Definition Pin
Logic
Symbol
2
LVTTL-O
TX_Fault
3
LVTTL-I
TX_Disable
4
LVTTL-I/O
SDA
2- write Serial Interface Data Line
5
LVTTL-I/O
SCL
2- write Serial Interface Clock
1
VeeT
6
MOD_ABS
7
LVTTL-I
RS0
8
LVTTL-O
RX_LOS
9
LVTTL-I
Name/Description
Note
Module Transmitter Ground
1
Module Transmitter Fault
2
Transmitter Disable; Turns off transmitter laser output
3
Module Absent, connected to VeeT or VeeR in the module
4
Not Implement Receiver Loss of Signal Indication
2
RS1
Not Implement
10
VeeR
Module Receiver Ground
1
11
VeeR
Module Receiver Ground
1
12
CML-O
RD-
Receiver Inverted Data Output
13
CML-O
RD+
Receiver Non-Inverter Data Output
DELTA ELECTRONICS, INC.
4
Revision: S3 5/30/2013
www.deltaww.com
Product Datasheet SAOC-10G1F2A 14
VeeR
Module Receiver Ground
15
VccR
Module Receiver 3.3V Supply
16
VccT
Module Transmitter 3.3V Supply
17
VeeT
Module Transmitter Ground
18
CML-I
TD+
Transmitter Non-Inverted Data Input
19
CML-I
TD-
Transmitter Inverted Data Input
20
VeeT
1
1
Module Transmitter Ground
1
Note: 1. The module signal ground pins, VeeR and VeeT, shall be isolated from the module case. 2. This pin is an open collector/drain output pin and shall be pulled up with 4.7k-10k ohms to Host_Vcc on the host board. Pull ups can be connected to multiple power supplies, however the host board design shall ensure that no module pin has voltage exceeding module VccT/R + 0.5V. 3. This pin is an open collector/drain input pin and shall be pulled up with 4.7k-10k ohms to VccT in the Module. 4. This pin shall be pulled up with 4.7k-10k ohms to Host_Vcc on the host board.
DELTA ELECTRONICS, INC.
5
Revision: S3 5/30/2013
www.deltaww.com
Product Datasheet SAOC-10G1F2A 6. Low Speed Electrical Hardware Pins In addition to the 2-wire serial interface, the SFP+ module has the following low speed pins for control and status: ‧ TX_Fault ‧ TX_Disable ‧ RS0/RS1 ‧ MOD_ABS ‧ RX_LOS 1 TX_Fault TX_Fault is a module output pin that when High, indicates that the module transmitter has detected a fault condition related to laser operation or safety. The TX_Fault output pin is an open drain/collector and must be pulled p to the Host_Vcc with 4.7k-10k ohms on the host board 2 TX_Disable TX_Disable is a module input pin. When TX_Disable is asserted High or Left open, the SFP+ module transmitter output must be turned off. The TX_DIS pin must be pulled up to VccT in the SFP+ module.. 3 RS0/RS1 RS0 and RS1 are module input rate select pins and are pulled low to VeeT with a > 30kΩ resistor in the module. RS0 is an input hardware pin which optionally selects the optical receive data path rate coverage for an SFP+ module. RS1 is an input hardware pin which optionally selects the optical transmit path data rate coverage for an SFP+ module. 4 MOD_ABS Mod_ABS is pulled up to Host_Vcc with 4.7k-10k ohms on the host board and connected to VeeT or VeeR in the SFP+ module. MOD_ABS is then asserted “High” when the SFP+ module is physically absent from a host slot. In the SFP MSA (INF8074i) this pin had the same function but is called MOD_DEF0. 5 SCL/SDA SCL is the 2-wire interface clock and SDA is the 2-wire interface data line. SCL and SDA are pulled up to a voltage in the range of 3.14V to 3.46V on the host. 6 RX_LOS RX_LOS when High indicated an optical signal level below that specified in the relevant standard. The RX_LOS pin is an open drain/collector output and must be pulled up to host Vcc with a 4.7k-10k ohms on the host board. RX_LOS assert min and de-assert max are defined in the relevant standard.
DELTA ELECTRONICS, INC.
6
Revision: S3 5/30/2013
www.deltaww.com
Product Datasheet SAOC-10G1F2A 7. Recommended Circuit Schematic
DELTA ELECTRONICS, INC.
7
Revision: S3 5/30/2013
www.deltaww.com
Product Datasheet SAOC-10G1F2A
8. Mechanical Specification Parameter
Symbol
Min
Typ
Max
Units
AOC cable length (L <=5m) AOC cable length (L > 5m) Module Retention
L L
L-0.06 L-(1.1%*L) 90
L L
L+0.06 L+(1.1%*L) 170
M M N
18 12.5
N N
Module Insertion Module Extraction Cable Pull Strength – Apply Load at 0° Cable Pull Strength – Apply Load at 90° Clearance Out of IO Bezel Cable Bending Radius Insertion / Removal Cycles
DELTA ELECTRONICS, INC.
0 0 44
N
33
N
75
mm
30 50
mm cycles
8
Notes
Revision: S3 5/30/2013
www.deltaww.com
Product Datasheet SAOC-10G1F2A 9. Mechanical Outline Dimensions
Label Specification: SAOC-10G1F2Ay1y2 850 nm 10G SFP+ y1y2 M MADE IN TAIWAN
YYWWDDLXXXXX
DELTA ELECTRONICS, INC.
9
Revision: S3 5/30/2013
www.deltaww.com
Product Datasheet SAOC-10G1F2A
10. Regulatory Compliance Feature
Reference
Electromagnetic Interference (EMI)
FCC Part15 Class B
Electrostatic Discharge (ESD)
IEC/EN 61000-4-2 MIL-STD-883G EIA-JESD22-A115-A
Laser Eye Safety
FDA 21CFR 1040.10, 1040.11
Component Recognition
UL60950
11. Ordering information Model No: SAOC-10G1F2Ay1y2 y1y2: Length 01: 1 meter 02: 2 meters 03: 3 meters 05: 5 meters 10: 10 meters 20: 20 meters A0: 100 meters Others: customized length
12. Revision History Version No.
Date
S0
2012-03-29
Description Initial draft release Change output swing to 150 to 850mV.
S1
2012-08-05
Change Icc to 300mA. Change Pd to 1W. Update mechanical outline drawings and photo.
S2
2013-01-29
Change mechanical spec.
S3
2013-05-30
P8: Add label specification.
DELTA ELECTRONICS, INC.
10
Revision: S3 5/30/2013
www.deltaww.com