Transcript
SFP-WA10-T 1.25 Gigabit Ethernet-Single Mode Transceiver SFP BIDI, Single LC Connector, 1310nm FP LD for Single Mode Fiber, RoHS Compliant Features
Applications • • • •
Gigabit Ethernet Links Fiber Channel Links at 1.06 Gbps High Speed Backplane Interconnects Switched Backbones
RoHS Pb
•
1310nm FP LD
•
Multi Data Rate: from 125M to 1.25Gbps, NRZ
•
Single +3.3V Power Supply
•
RoHS Compliant and Lead-free
•
AC/AC Differential Electrical Interface
•
Compliant with Multi-Source Agreement (MSA) Small Form Factor Pluggable (SFP)
•
Single LC Connector
•
Compliance with specifications for IEEE-802.3z Gigabit Ethernet at 1.25 Gbps
•
Compliance with ANSI specifications for Fiber Channel applications at 1.06 Gbps
•
Eye Safety Designed to meet Laser Class 1, complies with EN60825-1
Description The SFP-WA10-T from AAXEON is the high performance and cost-effective module for serial optical data communication applications specified for single mode of 1.25 Gb/s. It operates on +3.3V power. The module is intended for single mode fiber, operates at a nominal wavelength of Tx: 1310nm / Rx: 1550nm, and complies with Multi-Source Agreement (MSA) Small Form Factor Pluggable (SFP). Each module consists of a bi-directional optical subassembly that combines a transmitter with a receiver and an electrical subassembly. All are housed in a metal package and the combination produces a reliable component. The module is a single fiber connector transceiver designed for use in Gigabit Ethernet applications and to provide IEEE-802.3z compliant link for 1.25Gb/s intermediate reach applications. The characteristics are performed in accordance with Telcordia Specification GR-468-CORE.
EMC Most equipment utilizing high-speed transceivers will be required to meet the following requirements: 1) FCC in the United States 2) CENELEC EN55022 (CISPR 22) in Europe To assist the customer in managing the overall equipment EMC performance, the transceivers have been designed to satisfy FCC class B limits and provide good immunity to radio-frequency electromagnetic fields.
Eye Safety The transceivers have been designed to meet Class 1 eye safety and comply with EN 60825-1. Page 1 of 6 www.aaxeon.com
SFP-WA10-T 1.25 Gigabit Ethernet-Single Mode Transceiver Product Information Model Number SFP-WA10-T
Operating Voltage Distance & SD Output 3.3V TTL AC/AC 10 km
Wavelength
Output Power Sensitivity
1310 nm FP / 1550 nm
-9 ~ -3 dBm
≤-21 dBm
UNIT °C V V mA
NOTE
ABSOLUTE MAX RATINGS PARAMETER Storage Temperature Supply Voltage Data Input Voltage Supply Current
SYMBOL TS VCC --IS
MIN -40 0 0
SYMBOL TA VCC VID
MIN. -40 3.1 300
MAX 85 6 Vcc 300
OPERATING CONDITIONS PARAMETER Case Operating Temperature Supply Voltage Data Input Voltage Swing
TYP.
MAX. 85 3.5 1860
UNIT °C V mV
NOTE
ELECTRICAL CHARACTERISTICS PARAMETER Transmitter Transmitter Supply Current Tx_ Disable Input Voltage - Low Tx_ Disable Input Voltage - High Tx_ Fault Output Voltage - Low Tx_ Fault Output Voltage - High Receiver Receiver Supply Current Receiver Data Output Differential Voltage
Rx_LOS Output Voltage - Low Rx_LOS Output Voltage - High MOD_DEF (1) , MOD_DEF (2) - Low MOD_DEF (1) , MOD_DEF (2) - High
SYMBOL
MIN
MAX
UNIT
ICCT VIL VIH VOL VOH
0 2.0 0 2.0
200 0.8 Vcc 0.8 Vcc
mA V V V V
ICCR VOD VOL VOH VIL VIH
0.4 0 2.0 -0.6 Vcc × 0.7
100 1.3 0.8 Vcc Vcc × 0.3 Vcc + 0.5
mA V V V V V
NOTE
TRANSMITTER ELECTRO-OPTICAL CHARACTERISTICS PARAMETER Optical Output Power Extinction Ratio Center Wavelength Spectral Width (RMS) RIN Optical Rise time (20%-80% ) Optical Fall time (20%-80% ) Output Eye
SYMBOL Po ER λc Δλ RIN tr tf
MIN -9 9 1270
TYP.
MAX -3
1355 2.5 -120 260 260 Compliant with IEEE802.3z/D5.0
UNIT dBm dB nm nm dB/Hz ps ps
NOTE 1
2 2
Page 2 of 6 www.aaxeon.com
SFP-WA10-T 1.25 Gigabit Ethernet-Single Mode Transceiver RECEIVER ELECTRO-OPTICAL CHARACTERISTICS PARAMETER Maximum Input Optical Power
Minimum Input Optical Power
1.25Gb/s
-21
NOTE 3 3
1.06Gb/s
-21
3
622Mb/s
SYMBOL Pmax
MIN -3
TYP.
MAX
-21
Pmin
UNIT dBm
dBm
4
155Mb/s
-21
4
125Mb/s
-21 1580
3
Operating Wavelength Optical Return Loss Receiver Electrical 3dB Upper Cutoff Frequency
LOS of Signal - Asserted LOS of Signal - Deasserted Loss of Signal -Hysterisis
λ ORL
1480 14
--PA PD PD -PA
nm dB
1500
MHz
-20
dBm dBm dB
-35 0.5
Notes: 1. Measured average power coupled into 9/125μm single mode fiber. 2. These are 20-80% values. 7 -12 3. Measured with 2 -1 PRBS at BER<10 23 -10 4. Measured with 2 -1 PRBS at BER<10
TIMING CHARACTERISTICS PARAMETER TX_DISABLE Assert Time TX_DISABLE Negate Time Time to initialize, include reset of TX_FAULT TX_FAULT from fault to assertion TX_DISABLE time to start reset Receiver Loss of Signal Assert Time (off to on) Receiver Loss of Signal Assert Time (on to off)
SYMBOL t_off t_on t_init t_fault t_reset
MIN
TYP.
MAX 10 1 300 100
UNIT μs ms ms μs μs
tA,RX_LOS
100
μs
tD,RX_LOS
100
μs
10
NOTE
Page 3 of 6 www.aaxeon.com
SFP-WA10-T 1.25 Gigabit Ethernet-Single Mode Transceiver BLOCK DIAGRAM OF TRANSCEIVER Electrical Sub-assembly TD+ TD-
LD Driver
TX Disable
WDM Optical Sub-assembly
FP-LD
TX Fault (0) (1) (2)
MOD_DEF PreAmp
RD+ RD-
Single LC Receptacle Connector
Post-Amp
RX_LOS
Page 4 of 6 www.aaxeon.com
SFP-WA10-T 1.25 Gigabit Ethernet-Single Mode Transceiver PIN OUT DIAGRAM OF TRANSCEIVER 20
VEET
1
VEET
19
TD-
2
Tx Fault
18
TD+
3
Tx Disable
17
VEET
4
MOD-DEF2
16
VCCT
5
MOD-DEF1
15
VCCR
6
MOD-DEF0
14
VEER
7
Rate Select
13
RD+
8
LOS
12
RD-
9
VEER
11
VEER
10
VEER
Buttom of Board (As Viewed through Top of Board
Top of Board
PIN OUT TABLE Pin
Symbol
Functional Description
1
VeeT
Transmitter Ground
2
TX Fault
Transmitter Fault Indication
3
TX Disable
Transmitter Disable – Module disables on high or open
4
MOD-DEF(2)
Module Definition 2 – Two wire serial ID interface
5
MOD-DEF(1)
Module Definition 1 – Two wire serial ID interface
6
MOD-DEF(0)
Module Definition 0 – Grounded in module
7
Rate Select
Not Connected
8
LOS
Loss of Signal
9
VeeR
Receiver Ground
10
VeeR
Receiver Ground
11
VeeR
Receiver Ground
12
RD-
Inverse Received Data Out
13
RD+
Received Data Out
14
VeeR
Receiver Ground
15
VccR
Receiver Power
16
VccT
Transmitter Power
17
VeeT
Transmitter Ground
18
TD+
Transmitter Data In
19
TD-
Inverse Transmitter Data In
20
VeeT
Transmitter Ground
Page 5 of 6 www.aaxeon.com
SFP-WA10-T 1.25 Gigabit Ethernet-Single Mode Transceiver RECOMMENDED CIRCUIT SCHEMATIC Vcc VEET
VCCT
RES
Tx Fault RES
Tx Disable
100
LD Driver
TD+
Z o = 50 Ω
TD-
Z o = 50 Ω
Vcc L1 VCCT
C2 L2
VCCR
Pre Amp
Post Amp
C3
C1
RD-
Z o = 50 Ω
RD+
Z o = 50 Ω
System 100Ω
Vcc RES
RES
RES
EEPROM
RES
RX_LOS MOD-DEF(2) MOD-DEF(1) MOD-DEF(0)
Note : 4.7 K Ω < RES < 10 KΩ L1, L 2 = 1mH C1 = 10mF C 2, C 3 = 0.1mF
MECHANICAL DIMENSIONS Units in mm