Transcript
APPROXIMATE PRODUCT MASS (LBS)
REVISIONS
SGI 225
SGI 250, 266, 300
SGI 500, 500PE
INSTALLED MASS:
5170
5650
6980
SHIPPING MASS:
5380
5860
7190
NOTES: 1. SEE SOLECTRIA RENEWABLES SGI 225, 250, 266, 300, 500 AND 500PE INSTALLATION AND OPERATION MANUAL FOR FURTHER INSTALLATION REQUIREMENTS. 2. CUSTOMER INTERFACE DRAWING SHEETS INCLUDE: 1. FRONT ISOMETRIC 2. FRONT 3. REAR 4. RIGHT 5. LEFT 6. TOP 7. BOTTOM 8. AS SHIPPED ISOMETRIC 9. RECOMMENDED RIGGING AND LIFTING METHODS
RENEWABLES WWW.SOLECTRIA.COM
PRODUCT:
SGI 225-500PE
VIEW:
FRONT ISOMETRIC
DOCUMENT: SIZE:
B
DOCR-070257 ALL DIMENSIONS ARE IN INCHES
REV:
D
DO NOT SCALE
CUSTOMER INTERFACE DRAWING PLEASE NOTE: ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE
SCALE:
1:15
ISO 04-04-26 REV. A
SHEET
1 OF 9
REV
EC#
DESCRIPTION
DRAWN
DATE
J. KADOKO
3/26/2013
C. THOMPSEN
10/17/2013
1185 • REVISION TO PALLET
C. THOMPSEN
4/14/2014
NEW REVISION OF AIR INTAKE SHROUDS 1388 • • ADDED SHROUDS TO EXHAUST
A. MARINELLA
4/14/2015
A
1052 • INITIAL RELEASE
B
• • 1059 • • •
C D
ENCLOSURE LIFT EYES CHANGED TO LIFT TABS NEW REVISION OF AIR INTAKE SHROUDS WITH ANGLED TOP NEW AC BREAKER AND DC DISCONNECT ROTARY HANDLES ADDED AC/DC CONDUIT ENTRY COLLAR TO MODEL ADDED RIGGING AND LIFTING SHEET
NOTES: 1. DIMENSIONS INDICATED BY (COG) SHOW APPROXIMATE LOCATION OF THE INVERTER CENTER OF GRAVITY.
12 MINIMUM DISTANCE THAT MUST BE CLEAR ABOVE THE INVERTER FOR VENTILATION
6 UNIT LIFTING LOCATIONS
1.5
60
6 MINIMUM DISTANCE THAT MUST BE CLEAR TO EACH SIDE OF THE INVERTER FOR VENTILATION
79
30 (COG)
4
RENEWABLES WWW.SOLECTRIA.COM
PRODUCT:
SGI 225-500PE
VIEW: DOCUMENT: SIZE:
4
FRONT
B
DOCR-070257 ALL DIMENSIONS ARE IN INCHES
REV:
D
DO NOT SCALE
CUSTOMER INTERFACE DRAWING PLEASE NOTE: ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE
SCALE:
1:12
ISO 04-04-26 REV. A
SHEET
2 OF 9
70 (COG) 109
82
EXHAUST AIR SHROUDS
ALTERNATE AC CONDUIT ENTRY LOCATION 33
7
13
11.65
RENEWABLES WWW.SOLECTRIA.COM
PRODUCT:
VIEW:
REAR
DOCUMENT: SIZE:
49
SGI 225-500PE
B
DOCR-070257 ALL DIMENSIONS ARE IN INCHES
REV:
D
DO NOT SCALE
CUSTOMER INTERFACE DRAWING PLEASE NOTE: ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE
SCALE:
1:12
ISO 04-04-26 REV. A
SHEET
3 OF 9
12
18.31
NOTES: 1. NUMBER OF AIR INTAKE SHROUDS OR AIR FILTER SHROUDS DEPENDS ON INVERTER POWER LEVEL. REFER TO TABLE. SGI 225, 250, 266, 300
SGI 500, 500PE
2
3
NUMBER OF SHROUDS
29.6
AIR FILTER SHROUD
STANDARD AIR INTAKE SHROUD
BOTTOM SHROUD NOT INSTALLED DEPENDING ON POWER LEVEL. SEE TABLE.
BOTTOM SHROUD NOT INSTALLED DEPENDING ON POWER LEVEL. SEE TABLE.
RENEWABLES WWW.SOLECTRIA.COM
PRODUCT:
SGI 225-500PE
VIEW:
RIGHT
DOCUMENT: SIZE:
B
DOCR-070257 ALL DIMENSIONS ARE IN INCHES
REV:
D
DO NOT SCALE
CUSTOMER INTERFACE DRAWING PLEASE NOTE: ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE
SCALE:
1:12
ISO 04-04-26 REV. A
SHEET
4 OF 9
8
7
WITHOUT AIR FILTER OPTION
10
WITH AIR FILTER OPTION
NOTES: 1. DIMENSIONS INDICATED BY (COG) SHOW APPROXIMATE LOCATION OF THE INVERTER CENTER OF GRAVITY.
ALTERNATE DC CONDUIT ENTRY LOCATIONS
34
30 (COG) 18 4.5 RENEWABLES
16 (COG)
WWW.SOLECTRIA.COM
PRODUCT:
SGI 225-500PE
VIEW:
SIZE:
36
LEFT
DOCUMENT:
B
DOCR-070257 ALL DIMENSIONS ARE IN INCHES
REV:
D
DO NOT SCALE
CUSTOMER INTERFACE DRAWING PLEASE NOTE: ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE
SCALE:
1:12
ISO 04-04-26 REV. A
13
SHEET
5 OF 9
0.5
21
NOTES: 1. DOORS CAN SWING MORE THAN 90°.
0.56
6X
60.0
43.5 41.5
THESE DIMENSIONS ARE TO MOUNTING HOLES (HIDDEN BY EXHAUST SHROUDS)
45.0
18 MINIMUM DISTANCE THAT MUST BE CLEAR BEHIND THE INVERTER FOR VENTILATION AND MAINTENANCE ACCESS
36
25
RENEWABLES WWW.SOLECTRIA.COM
PRODUCT:
SGI 225-500PE
VIEW:
TOP
DOCUMENT: SIZE:
B
DOCR-070257 ALL DIMENSIONS ARE IN INCHES
REV:
D
DO NOT SCALE
CUSTOMER INTERFACE DRAWING PLEASE NOTE: ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE
SCALE:
1:12
ISO 04-04-26 REV. A
SHEET
6 OF 9
29
DC AND AC CONDUIT FLOOR ENTRY LOCATION
0.13 DRAIN HOLES
4
28.0 KEEP CONDUIT AT LEAST 1 INCH FROM EDGES OF OPENING
6.8
4.0
23.0 25.0
RENEWABLES WWW.SOLECTRIA.COM
PRODUCT:
SGI 225-500PE
VIEW:
BOTTOM
DOCUMENT: SIZE:
B
DOCR-070257 ALL DIMENSIONS ARE IN INCHES
REV:
D
DO NOT SCALE
CUSTOMER INTERFACE DRAWING PLEASE NOTE: ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE
SCALE:
1:12
ISO 04-04-26 REV. A
SHEET
7 OF 9
NOTES: 1. THE INVERTER IS SHIPPED ON AN OVERSIZED SHIPPING PALLET. IT IS RECOMMENDED TO KEEP THE INVERTER SECURED TO THE PALLET AND MOVED AS CLOSE AS POSSIBLE TO THE FINAL LOCATION PRIOR TO REMOVING THE PALLET.
5.5 29
36 45 RECOMMENDED FORK LIFT LOCATIONS 120
48
48
120
22 RENEWABLES WWW.SOLECTRIA.COM
PRODUCT:
VIEW:
SGI 225-500PE
AS SHIPPED ISOMETRIC
DOCUMENT: SIZE:
B
DOCR-070257 ALL DIMENSIONS ARE IN INCHES
REV:
D
DO NOT SCALE
CUSTOMER INTERFACE DRAWING PLEASE NOTE: ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE
SCALE:
1:22
ISO 04-04-26 REV. A
SHEET
8 OF 9
WITHOUT AIR FILTER OPTION
WITH AIR FILTER OPTION
NOTES: 1. RECOMMENDED SINGLE POINT LIFTING METHOD SHOWN. SEE SOLECTRIA RENEWABLES SGI 225, 250, 266, 300, 500 AND 500PE INSTALLATION AND OPERATION MANUAL FOR PREFERED LIFTING METHODS AND ADDITIONAL LIFTING AND INSTALLATION REQUIREMENTS.
15 FEET MINIMUM
RECOMMENDED FORK LIFT LOCATIONS ARE INDICATED BY LABELS
RENEWABLES WWW.SOLECTRIA.COM
PRODUCT:
VIEW:
SGI 225-500PE
RECOMMENDED RIGGING AND LIFTING METHODS
DOCUMENT: SIZE:
B
DOCR-070257
ALL DIMENSIONS ARE IN INCHES
REV:
D
DO NOT SCALE
CUSTOMER INTERFACE DRAWING PLEASE NOTE: ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE
SCALE:
1:32
ISO 04-04-26 REV. A
SHEET
9 OF 9
RECOMMENDED FORK LIFT LOCATIONS ARE INDICATED BY LABELS
45
56