Preview only show first 10 pages with watermark. For full document please download

Sheet No. Component /detail Description

   EMBED


Share

Transcript

Sheet No. Component /Detail 1 Draw ing Guide 2 -3 Solution Isometric 4-6 Solution General Arrangement 7 Solution Anchoring Details 8-13 UPS Internal view s & Details 14-16 17-18 Description Galaxy VM 180 kVA 1 Module UPS w ith Classic Battery Cabinet Draw ing Guide Galaxy VM 180 kVA 1 Module UPS w ith Classic Battery Cabinet Solution Isometric Galaxy VM 180 kVA 1 Module UPS w ith Classic Battery Cabinet Solution General Arrangements Galaxy VM 180 kVA 1 Module UPS w ith Classic Battery Cabinet Solution Anchoring Details Galaxy VM 180 kVA 1 Module UPS w ith Classic Battery Cabinet UPS Internal view s & Details Battery Cabinet Internal View s & Details Galaxy VM 180 kVA 1 Module UPS w ith Classic Battery Cabinet Battery Cabinet Internal View s System One Line Diagram Galaxy VM 180 kVA 1 Module UPS w ith Classic Battery Cabinet System One Line Diagram Floor Loading Data SKU # 0G-GVMPB160K180D (Power Cabinet) 0G-GVMI225KG (I/O Cabinet) GVMSB180KGS (UPS) 77.56x23.62x33.62 [1970x600x854] Weight in lb [kg] 1032 [469] 77.56x11.81x33.62 [1970x300x854] 463 [210] 168 [820] 77.56x39.45x33.62 [1970x1002x854] 1495 [679] 163 [796] Dimensions HxWxD in Inches [mm] GVMCBC2WUE (Battery Cabinet A and B) 77.56x85.04x33.62 [1970x2160x854] 7997 [3635] Floor Loading in lb/ft 2 [kg/m2] 188 [917] 404 [1971] CENTER OF GRAVITY Center of Gravity in Inches [mm] X-Distance Y-Distance Z-Distance Power Cabinet 11.81 [300] 37.40 [950] 14.92 [379] I/O Cabinet 7.48 [190] 33.46 [850] 9.02 [229] Battery Cabinet A/B 17.71 [450] 39.37 [1000] 15.75 [400] Cabinet ELECTRICAL DATA SHEET VIN/VOUT 480V/480V UPS RATING AT 0.9 PF LAG. 180kVA INPUT VOLTAGE 480VAC 3PH 60HZ, WIRING : 3 WIRE -3PH+G BYPASS VOLTAGE 480VAC 3PH 60HZ, WIRING : 3 WIRE -3PH+G, 4WIRE- 3PH+N+G UPS INPUT NOMINAL INPUT CURRENT (A) 204 INPUT CURRENT LIMITATION (A) 278 MAXIMUM INPUT CURRENT (A) 278 UPS BYPASS INPUT CURRENT (A) 217 OUTPUT VOLTAGE 480VAC 3PH 60HZ, WIRING : 3 WIRE -3PH+G, 4WIRE- 3PH+N+G NOMINAL OUTPUT CURRENT (FULL LOAD) (A) 217 NOMINAL BATTERY VOLTAGE (VDC) 480 END OF DISCHARGE VOLTAGE (FULL LOAD) (VDC) 384 BATTERY CURRENT AT FULL LOAD AND NOMINAL BATTERY VOLTAGE (A) 352 BATTERY CURRENT AT FULL LOAD AND MINIMUM BATTERY VOLTAGE (A) 440 THDI < 3%@ 100% LOAD, <4% @ 50% LOAD, <6% @ 25% LOAD THDV < 2%@ 100% LINEAR LOAD, < 3%@ 100% NON-LINEAR LOAD MAXIMUM SHORT CIRCUIT WITHSTAND 65kA @ RECOMMENDED BREAKER SIZE REQUIRED UPSTREAM INPUT BREAKERS 80% RATED/100%RATED LJL36400U31X- 400A/ LJL36400CU31X-400A REQUIRED UPSTREAM BYPASS BREAKERS 80% RATED/100%RATED LJL36400U31X- 400A/JJL36225C-225A RECOMMENDED INPUT CABLE SIZE 80% RATED/ 100% RATED BREAKERS (2) 2/0 AWG / (2) 1/0 AWG RECOMMENDED BYPASS CABLE SIZE 80% RATED/ 100% RATED BREAKERS (2) 2/0 AWG / 250 kcmil RECOMMENDED OUTPUT CABLE SIZE 80% RATED/ 100% RATED BREAKERS (2) 2/0 AWG / 250 kcmil RECOMMENDED BATTERY CABLE SIZE 80% RATED/ 100% RATED BREAKERS (2) 4/0 AWG / (2) 4/0 AWG HEAT DISSIPATION @100% LOAD (BTU/hr) [kW] NORMAL OPERATION / ECO MODE (21160) [6.2] / (2930) [0.86] Air flow @ 100% Load 3700m³@40°C, 3200m³@30°C, 2800m³@20°C ELECTRICAL DATA SHEET VIN/VOUT 480V/480V UPS RATING AT 0.9 PF LAG. 180kVA INPUT VOLTAGE 480VAC 3PH 60HZ, WIRING : 3 WIRE -3PH+G, 4WIRE- 3PH+N+G UPS INPUT NOMINAL INPUT CURRENT (A) 204 INPUT CURRENT LIMITATION (A) 278 MAXIMUM INPUT CURRENT (A) 278 OUTPUT VOLTAGE 480VAC 3PH 60HZ, WIRING : 3 WIRE -3PH+G, 4WIRE- 3PH+N+G NOMINAL OUTPUT CURRENT (FULL LOAD) (A) 217 NOMINAL BATTERY VOLTAGE (VDC) 480 END OF DISCHARGE VOLTAGE (FULL LOAD) (VDC) 384 BATTERY CURRENT AT FULL LOAD AND NOMINAL BATTERY VOLTAGE (A) 352 BATTERY CURRENT AT FULL LOAD AND MINIMUM BATTERY VOLTAGE (A) 440 THDI < 3%@ 100% LOAD, <4% @ 50% LOAD, <6% @ 25% LOAD THDV < 2%@ 100% LINEAR LOAD, < 3%@ 100% NON-LINEAR LOAD MAXIMUM SHORT CIRCUIT WITHSTAND 65kA @ RECOMMENDED BREAKER SIZE REQUIRED UPSTREAM INPUT BREAKERS 80% RATED/100%RATED LJL36400U31X- 400A/ LJL36400CU31X-400A RECOMMENDED INPUT CABLE SIZE 80% RATED/ 100% RATED BREAKERS (2) 2/0 AWG / (2) 1/0 AWG RECOMMENDED OUTPUT CABLE SIZE 80% RATED/ 100% RATED BREAKERS (2) 2/0 AWG / 250 kcmil RECOMMENDED BATTERY CABLE SIZE 80% RATED/ 100% RATED BREAKERS (2) 4/0 AWG / (2) 4/0 AWG HEAT DISSIPATION @100% LOAD (BTU/hr) [kW] NORMAL OPERATION / ECO MODE (21160) [6.2] / (2930) [0.86] Air flow @ 100% Load 3700m³@40°C, 3200m³@30°C, 2800m³@20°C