Preview only show first 10 pages with watermark. For full document please download

Shillong – 793001 1. Modified Technical Specifications Annexed. 2

   EMBED


Share

Transcript

MEGHALAYA URBAN DEVELOPMENT AUTHORITY Shillong – 793001 CORRIGENDUM TO TENDER NOTICE NO. MUDA/MON/3/PT-I/2010-11/170 DATED 4TH OCTOBER, 2012. Name of Work: SUPPLY OF INTELLIGENT TRANSPORT SYSTEM FACILITIES FOR BUSES IN SHILLONG CITY UNDER JNNURM Corrigendum: 1. Modified Technical Specifications Annexed. 2. PIS for Bus Stops is Deleted. 3. Specifications for Closed Circuit Television System (pages 14 – 24) of previous tender document replaced by Item No. 17 & 18 of Technical Details of Modified Technical Specifications. Shillong, Meghalaya, India Phone : +91-0364-2227967 Fax : +91-0364-2227844   MEGHALAYA URBAN DEVELOPMENT AUTHORITY Shillong – 793001       Dated Shillong, the 17h October 2012. No. MUDA /MON/3/Pt-I 2010–11/174 CORRIGENDUM In partial amendment to Tender Notice No. MUDA/MON/3/Pt-I/2010-11/170 dated 4th October, 2012 for Intelligent Transport System (ITS) components and Multiplexing for Buses under JnNURM, Shillong, the modified technical specifications are hereby annexed to the tender document which may be viewed/downloaded from the website www.smb.gov.in. The item PIS for Bus Stops is not required and hence deleted. The date of submission of tender is extended to 15:00 hrs on 31st Oct. 2012 which will be opened on the same date at 15:30 hrs. There will be no pre-bid meeting in view of shortage of time. However, in case of any queries / clarification interested parties may email at [email protected] Other terms and conditions remain unchanged. - Sd /Secretary Meghalaya Urban Development Authority, Shillong.                                                       MODIFIED TECHNICAL SPECIFICATIONS  SCOPE OF WORK  1. General  Requirements.  1.1 The bidder should provide the required IT infrastructure hardware and software components to implement  the respective solution defined in the SRS.  1.2 The  bidder  shall  supply  the  required  equipment  and  devices  to  build  a  Close  Circuit  Television  solution  should  have  Control  and  Command  Centre/Operational  Control  Centre  facility  for  administration  and  monitoring.  1.3 The  bidder  shall  provide  preferably  rack  based  servers  with  appropriate  accessories,  monitoring    and  management tools.  1.4 The bidder shall provide appropriate storage capacity for the total solution.  1.5 The  bidder  should  provide  required  networking  operational  communication  network  including  necessary  hardware/equipment for respective domain.  1.6 The system network shall be designed in a way to meet performance requirements for the system such that  it  is  adaptable  and  can  meet  the  changing  business  requirements  including  reliability,  new  software  applications or service additions, high availability and security.  1.7 The  system  shall  be  designed  with  confidentiality  and  security  of  data  as  a  priority  and  its  design  will  include levels of redundancy, fault tolerance and disaster recovery based on business requirements.  1.8 The  bidder  shall  be  required  to  design,  supply,  install,  test,  commission,  operate  and  maintain  all  components of the network for their respective domain.  1.9 The entire Network shall be managed through a dashboard style of Graphical User Interface (GUI)  1.10 The bidder shall provide 3rd party Software, wherever required, to complete the required functionality of  the respective domain.  1.11 The bidder shall provide necessary mechanism with process to report faults and its resolution to measure  and monitor SLA (system level agreement)  1.12 The  bidder  shall  provide  the  required  Software  Development  Kit  (SDK)  and  Application  Programming  Interfaces(APIs) to enable integration with various systems.  1.13 The bidders should provide the required backend solution based on objective and minimum requirements.  The supplier is required to supply, design, install, test, commission, operate and maintain the solution for  the various systems as defined in the scope for the respective parts including manpower but not limited to:  i) All required IT Hardware infrastructure and software including server at Data Center.  ii) All required infrastructure and software which should include  a. Base Station with Control Centre.  b. Database and software to store CCTV surveillance and record information.  c. CCTV Application.  d. Surveillance  Review  software  with  zoom,  store,  forward  and  backward  viewing  facility  of      downloaded data.  e. Backup and restore facility for the solution.  iii) All requirements 3rd party Software such as Operating System, Antivirus etc.  iv) All requirements licenses to make CCTV operational.  v) Furniture and fixture required for operation.    2 Operational Control Centre (OCC)/ Control & Command Centre  2.1 An Operational Control Centre would be established at MUDA Office for regular monitoring, operations, reports  printing related work under CCTV.  The  required  LCD  screen,  computer  hardware,  software,  printer,  UPS  network,  connectivity,  antivirus,  Air  Conditioners, furniture & fixture will be delivered as per schedule.  The required space & electric connection / GSM Connections / Lease Lines for establishing an OCC will be provided  and bear by MUDA.     2.2 Delivery of Materials and Related Documentation: The successful bidder shall submit all documents on System  Architecture,  installation  Procedure,  /  drawing  for  all  equipment’s,  details  of  fault  diagnostics,  operating  and  maintenance manuals, FAT and SAT report of all equipment.    2.3 The successful bidder shall supply the following set of documents. All documents shall be English Language. An  index of all handbooks, drawing, design documents etc shall be available with each set.  a. Installation manual.  b. Equipment layout drawing   c. Cabling diagrams  d. Overall system Architecture, description of hardware/software  e. Schematic drawing of all circuit in the system  f. Equipment installation drawings  g. Installation instruction and testing procedures  h. Acceptance testing Procedure   i. Emergency action Procedure    2.4  The  successful  bidder  shall  submit  the  layout  drawing  of  deploy  of  CCTV  equipment’s  clearly  depicting  its  integration and logic flow with other devices and systems. The drawing shall be the “as built drawing“ and shall also  include the networking arrangements fully operational solution.    2.5  The  bidder  shall  provide  two  (2)  full  sets  of  documents  for  each  element  supplied.  This  documentation  shall  provide information on all aspect of installing the element.    2.6 The bidder shall submit all requirements documents for the goods/ materials and services as below:  (i) Installation, detail of fault diagnostics, operation and maintenance manual    2.7  All  documents  submitted  by  the  bidder  shall  be  in  the  form  of  bounded  hard  copies  along  with  softcopy  in  DVD/CDs.    3. Incident Services  The bidder shall be required to provide all of the following services:  3.1 The successful bidder shall be required to undertake the supply, design, install customize, integrate.  3.2 After initial maintenance period of three (3) years, MUDA may extend the services of the bidder for providing  maintenance services. The maintenance and support contract will be renewed for mutually agreed term based on  satisfactory performance of the previous period.  3.3 The condition of uptime commitment and service level parameters governing during the contract period shall  prevail for subsequent maintenance and support.   3.4 Development of close Circuit Television and security policy and procedure.    4. System Performance and Availability  (i) The IT Infrastructure for production environment should be designed in such a way that the infrastructure  shall be made available 99.5% without single point of failure.  (ii) The system shall be operational, reliable, and available (24 hours by 7 days per week, 365 days in the year)  for essential business processes and mission – critical business operation.  (iii) The key information losses should be zero.  (iv) The redundancy factor shall be such that the loan on any of the components shall no exceed 70% of the  capacity of full operation.  (v) The close Circuit Television and injection system shall be able to recover all keys generated and used before  the system goes down.  (vi) The disaster recovery of close circuit Television shall be designed in a manner that in the event of disaster,  the recovery system takes over within 1 to 5 minutes.  (vii)  System performance standards should meet industry standards based on the technology used. In general  the system should support   a) 1‐2 seconds response time for data input after pressing the enter (save) key to display a response.  b) 1.5 seconds response time for on‐line inquiry.        5. Data Backup and Archival  The bidder shall be responsible to put in place a mechanism for efficient data backup and recovery for the scoped  item at production and disaster recovery Centers. They shall develop a strategy for backup, archiving and recovery  of data and submit to MUDA for review and approval.    5.1 Data Backup and Recovery process  (i) Daily data backup of all devices and solution components shall be maintained in order to ensure continuity  of business operations.  (ii) Detailed recovery processes shall be laid to allow restoration of information from backup.  (iii) The  bidder  shall  need  to  ensure  that  data  is  complete  i.e.  no  data  is  lost  or  omitted  from  any  collection  and/or transmission at all levels of the system.  (iv) The backup of recovery will not take more than one hour. The functionalities and performance of system  shall not degrade during backup process.  (v) The system should have provision to identify and load from data archive if need arises.    6. Training  (i) The  bidder  should  provide  information  on  the  training  course  offered  with  duration  of  each  module  and  required knowledge for MUDA and its consortium staff to attend such courses.  (ii) Bidder should clearly specify with training schedule and infrastructure required for such training.  (iii) Bidder must ensure that adequate training shall be provided to MUDA Technical and operational staff to  handle first / second level maintenance and operation.     7. Load Testing and Stress Testing  (i) The  bidder  must  arrange  to  demonstrate  that  the  system  that  the  system  is  able  to  perform  under  high  load   a) CPU Utilization must not cross beyond 70% at any time of processing   b) Initialization load as prescribed in this document  Load testing test cases should also cover scenarios like NCMC initialization various key generations etc.  (ii) Stress testing scenario must be simulated in order to come down in a graceful way.    8. Documentation and Manuals  The  bidder  shall  provide  three  full  sets  of  Installation,  Configuration  and  Operating  documentation  for  each  element supplied. This documentation shall be written in English and provide information on all aspect of installing  the element.  There  will  be  a  requirement  for  provision  of  both  user  and  technical  documentation  to  support  the  ongoing  operation of the system. This will encompass:  (i) System and Database design  (ii) System Specification   (iii) Detailed functional specification   (iv) System Implementation strategy and plan  (v) Network an d security strategy and implementation plan   (vi) System Integration an d interface document with various modules, functions and devices  (vii) System and network texting including load test   (viii) User manual for the application association with the solution   (ix) Operation  Procedure  manual:  including  procedure  for  fault  logging,  helpdesk  and  support  and  fault  resolution.  (x) Training manual for all levels of operational staff  (xi) disaster contingency Plan and Procedure(s)  (xii) Any other relevant document  The  standards  of  documentation  required  should  be  such  that  all  elements  of  the  solution  can  be  maintained  effectively  in  terms  of  availability,  operation  and  control  by  the  user  without  any  referral  or  assistance  from  the  bidder.      9. Security Management  The CCTV shall be designed in a way to ensure maximum security of all sub – systems/ components of the system.  The CCTV system should be suitably protected from internal as well as external treats.  The main features of security Management will include, but not limited to the following:  (i) The system will e developed to be protected from the attack of viruses, malware, and intrusion. Etc.  (ii) The  bidder  shall  ensure  to  have  suitable  security  policies,  processes  and  monitoring  built‐in  the  solution  and enforced to the fullest extend to prevent unauthorized access, hacking, denial of service attack and/ or other  security threats/ vulnerabilities.  (iii) All critical information like the customer bank account details and other sensitive financial data (internal as  well as external) will be protected to meet applicable banking industry standards/ other applicable laws.    10. Operation, Maintenance and support  The  Operation  service  include  day  to  day  operation  of  CCTV  solution  and  provide  management  report  on  timely  basis for 24x7x365 system availability.  The bidder takes complete end‐ to‐ end responsibility to keep the system working and maintained the solution by  providing skilled resource and marked Service Level Agreement (SLAs).   The bidder should undertake corrective & preventive maintenance to resolve faults, restore service & minimize the  downtime and number of faults. Restore system if need arises. The bidder would have to provide assistance and  support to operational team and give emergency service if required.  The  following  software  maintenance  activities  should  be  provided  by  the  successful  bidder  through  the  contract  Period:  (i) Routine and Preventive maintenance service  (ii) Fixing of bugs and carrying out test as required  (iii) Assisting in interfacing with other application as required  (iv) Carrying  out  modification  up‐gradation  in  the  software  required  due  to  any  change  in  the  hardware/  equipment/ third party software specifications  (v) Installation,  re‐installation  and  reconfiguration  of  CCTV  and  its  associated  software  required  sue  to  any  reasons; and  (vi) Change, Incident, Problem and Release Management.  During the Period of contract, the bidder shall provide onsite support as per the plan agreed with MUDA. During  the  period  of  contract,  the  bidder  shall  under  take  repair,  maintenance  and  replacement  of  all  items  related  to  supply items/ related to supply items/ solutions provided by it during AMC Contract Period. The maintenance will  include all Preventive maintenance, unit replacement, on‐call maintenance and schedule replacement services.  The bidder shall maintain adequate stock of spare units for replacement, components/ spares, consumable, etc., to  minimize downtime.  The  bidder shall try  to anticipate  defects based on the alert and take proactive actions  to prevent occurrence of  actual  defects,  wherever  possible  and  rectify  defects  in  minimum  time.  The  bidder  should  also  establish  and  maintain and support plan addressing all aspects of the maintenance program.     11. Systems Requirement Specification  ACCTV  system  is  required  to  be  installed  in  the  public  transport  (Bus)  for  surveillance  of  security  and  safety  of  passenger travelling in the vehicle. The system should have the following components:  (i) In‐Bus Installation  a. 2 (two) Cameras in each Bus   Mini Bus‐Facing the entry /exit service door and at the middle of gangway   Standard Bus‐Facing the entry/exit service door  b. A MVDR (Mobile Video Digital Recorder) with minimum data storage for 500 hours and download facility  through USB ports.  (ii) Backend software to review/ search the recorded data   The CCTV solution should have the following minimum features and specification:        TECHNICAL DETAILS OF ITEMS TO BE SUPPLIED    1.   72” LCD TV 9     Sl.  REQUIRED SPECIFICATION  a.  Screen Size: 72″ Inch  OFFERED SPECIFICATION    REMARKS    Resolution: Full HD (1920 x 1080) Pixels  Backlight: LED   IPS‐Advanced LED LCD Panel: Yes  XD Engine: Yes  DivX through USB 2.0: Yes (DivX HD)  Clear Voice II: Yes  Mono/Stereo/Dual (MTS/SAP): Yes / Yes /  Yes  Audio Output (Watts – THD 10%): 10W +  10W + 5W(Sub Woofer)  Speaker System: 2 Way 3 Speakers  Dolby Digital Decoder: Yes  Simplink (HDMI‐CEC): Yes  PC Connectivity: Yes  USB 2.0: 3  HDMI In: 4  AV In: 1  RF In: 1  Digital Audio Out (Co‐Axial/Optical): 1  RGB In (D‐Sub 15 Pin): PC‐1  PC Audio Input: 1  Ethernet LAN: 1  Power Supply: 100‐240V / 50‐60Hz  Dimensions: 1694 x 386.3 x 114 mm  Weight: Approx. 65.5 kg      2.   Server     Sl.  REQUIRED SPECIFICATION  OFFERED SPECIFICATION  REMARKS  a.          E5645 1P 6GB / (1) (1) Intel® Xeon®  E5645 (2.40GHz/6‐core/12MB/80W) /  12MB (1 x 12MB) L3 cache / 6GB (3 x  2GB) PC3‐10600 (DDR3‐1333)  Registered DIMMs / Embedded NC326i  PCI Express Dual Port Gigabit Server  Adapter / Embedded HP Smart Array  P410i/256MB Controller/ 1) 750 Watt  Hot‐Plug (Redundancy enabled) power  supply / 3 fans ship standard/ Tower  (5U) , 8TB HDD  4.   Desktop Computer     Sl.  REQUIRED SPECIFICATION  a.  Form Factor b.  Processors c.  Chipset d.  Memory e.  Optical Drive f.  Storage g.  Drive Bays h.  Slots i.  Ports j.  Audio k.  Power Supplies l.  m .  Graphics Controller Display n.  NIC o.  Keyboard p.  Pointing Device Operating q.  Systems(as per choice) r.  Micro Tower Intel Core i7-3770 CPU , Quad ,3.4 Ghz, 8 MB Intel Q 75 4GB DDR3 PC3-8500 (1066MHz) Non ECC Memory(4 DIMM Slots )- Max upto 32 GB SATA Super Multi DVD Writer 8X of better Drive 500 GB SATA Harddisk Drive 7200RPM Total of Min. 4 Bays (Including - 2* 3.5"and 2 * 5.25") (1) PCI, (2) PCIe x1, (1) PCIe x16 ( 3.0 ) Front : 4 USB 2.0 , Microphone headphone Rear : 4 USB 3.0 , 2 USB 2.0 , one VGA, one DisplayPort, one RJ-45 Ethernet, one line in, one line out, one serial one parallel port and color coded PS/2 for keyboard and mouse 8-Channel High Definition Audio with Internal Speaker 320W standard efficiency or 90% high efficiency (HE ) power supply & Energy Star 5.0 Certified & GOLD EPEAT Integrated Intel Graphics Media Accelerator 4500 18.5" TFT Maximum Resolution 1366x768 @60Hz, TCO certified (Same make as PC) Integrated Gigabit (10/100/1000 NIC) LAN 104 keys US STD. keyboard (Same make as PC) Optical 2/3 Button Scroll Mouse (Same make as PC) (A) Preinstalled Genuine Windows 7 Professional Edition with media & Certificate of Authenticity (B) Preinstalled RHEL5/6 Workstation with media and OFFERED SPECIFICATION      REMARKS                                                                      s.  Antivirus (Optional) t.  Add on Memory (Optional) u.  Certifications subscription Kaspersky/Norton/AVG/McA fee/Bitdefender Antivirus with 1 Yr. Subscription Extra 2GB DDR3 PC3-8500 (1066-MHz) Non ECC Memory Certifications: For OEM : ISO 9001:2000 & For PC : UL/CSA, FCC and Windows certification & Linux (Redhat/ Suse Certification), Energy Star 5.0 Certified                 5.   L3 24 port Core Switch (Advance Modular Layer 3 Switch)    Sl.  REQUIRED SPECIFICATION  a.  Performance :    Switch Come with 48 copper ports of  10/100/1000 Mbps & 12 Fibre ports of  1Gbps as well 2 Nos. 10G port  Upgradation in Future    Chassis with minimum of 8 payload slots  with redundant dual active active core    350Mpps forwarding rate    Extensive wire‐speed traffic classification  for ACLs and QoS    Supports 10KB Jumbo frame size    Wire‐speed multicasting for CCTV traffic    640Gbps or more Switching Fabric    Up to 128 or 250K IPv4 routes    Up to 16K MAC addresses    Up to 2 or 4K layer 2 multicast entries    Up to 1K layer 3 IPv4 multicast entries    4K VLANs    Chassis shall have IPV4 and IPV6 in  hardware  b.  Reliability :    Mean Time Between Failures: 185000  hours or more    Dual hot swappable PSUs with 1 + 1  redundancy    Hot‐swappable modules    Hot swappable fan modules    Switches shall support graceful restart for  OSPF/BGP/IS‐IS  c.  IEEE Standards :    IGMPv3, Internet Group Management  Protocol v2 (IGMPv2), PIM‐SM, OSPFv2  OFFERED SPECIFICATION      REMARKS                                                                                        IEEE 802.1v VLAN classification by  protocol & port    IEEE 802.3ac VLAN tagging    IEEE 802.1ad VLAN double tagging (Q‐in‐ Q)    Configurable Guest and Auth Fail VLANs.    RADIUS     RADIUS Accounting    RADIUS Attributes for Tunnel Protocol  Support    IEEE 802.1p Priority Tagging    DiffServ Precedence for 8 queues/port    DiffServ Architecture    IEEE 802.1D Spanning Tree Protocol (STP)  ‐ MAC Bridges    IEEE 802.1s Multiple Spanning Tree  Protocol (MSTP)    IEEE 802.1t ‐ 2001 801D maintenance    IEEE 802.1w ‐ 2001 Rapid Spanning Tree  Protocol (RSTP)  d.  Routing :    Advanced routing protocol like RIPing,  OSPFv3, BGPv4+, VRRPv3    Up to 5K RIP routes    Up to 15K OSPF routes    Up to 5K BGP routes    Up to 5K RIPng routes    VLAN support    IPv6 routing option    Supports 4096 VLANs    Virtual Routing and Forwarding (VRF) Lite  e.  Security    801x support    Dynamic and Private VLANs    NAC or equivalent    BPDU Protection    STP Root Guard    RADIUS server    Port, Web and MAC Based Authentication  f.  Quality of Service    Policy based QoS features    Highly configurable traffic classification    Mixed scheduling, to support complex  traffic queuing requirements    8 QoS queues per port    Two‐rate three‐contrasting colors  bandwidth metering, with burst sizes of  64 Kbps                                                                                                                                                            Access Control Lists (ACLs) and IEEE  802.1p Priority Tagging  g.  IPv6 Features:‐    IPv4 and IPv6 Dual Stack    IPv6 Management via Ping, TraceRoute,  Telnet and SSH    Static Unicast Routes for IPv6    RFC 1886 DNS Extensions to support IPv6    RFC 1887 An Architecture for IPv6 Unicast  Address Allocation    RFC 2461 Neighbour Discovery for IPv6    RFC 2462  IPv6 Stateless Address  Autoconfiguration    RFC 2464 Transmission of IPv6 Packets  over Ethernet Networks    RFC 2711 IPv6 Router Alert Option    RFC 3056 Connection of IPv6 Domains via  IPv4 Clouds    RFC 3513 IPv6 Addressing Architecture    RFC 4443 Internet Control Message  protocol (ICMPv6)  h.  Management :    GUI, Telnet, Industry‐standard CLI with  built‐in Help    SD/SDHC memory card socket allowing  software release files, configurations and  other files to be  stored for backup and distribution to  other devices    Support sFlow or Equivalent    RMON (4 groups)    Out of band 10/100/1000 Ethernet  management port and console  management port    SSH and SNMPv3 for secure management    Local RADIUS database and RADIUS  Authentication  i.  Electrical Approvals and Compliances    EMC: EN55022 class A, FCC class A, VCCI  class A    Immunity: EN55024, EN61000‐3‐levels 2  (Harmonics), and 3 (Flicker)  j.  Safety :    Standards: UL60950‐1,    Certification: UL, cUL, TUV    Restrictions on Hazardous Substances  (RoHS) Compliance    Power Characteristics    AC Voltage: 100 to 240V (+/‐10% auto                                                                                                                              ranging)    Frequency: 47 to 63Hz with 1+1 PSU  k.  Power Consumption :    700W or less  l.  Environmental Specifications :    Operating Temperature Range: 0°C to  40°C    Contractors must provide an OEM  authorization confirming the compliance  to above technical specifications, along  with the OEM authorization letter.                              6.   Distribution Switch     Sl.  REQUIRED SPECIFICATION  a.  Port Density and Redundancy    The  switch  shall  have  at  least  24  ports  of  10/100/1000  Base‐T  which  share  the  same  switch  fabric  and    4  ports  of  SFP  Slots  (Small  Form‐factor  Pluggable,  Combo port) Loaded with 1000 Base LX     The  switch  shall  have  at  least  4  ports  of  10G SFP+ slots     Redundant Power Supply available to load  share  with  internal  power  supply,  providing  uninterrupted  power  and  extra  reliability  b.  Performance    The switch shall support at least 136 Gbps  Switching capacity    The switch shall support at least 100 Mpps  forwarding rate (as 64Byte per packet)    Support 48Gbps of stacking bandwidth    Supports 9KB jumbo frames    Support Wire speed multicasting    Support Up to 32K MAC addresses    Support 8K Layer 3 entries    The switch shall be able to configure IP  address to 2000 VLAN.    Full environmental monitoring of PSUs,  fans, temperature and internal voltages.  SNMP traps alert network managers in  case of any failure  c.  VLAN Support    Generic VLAN Registration Protocol  (GVRP)      OFFERED SPECIFICATION  REMARKS                                                                      IEEE 802.1ad Provider bridges (VLAN  stacking, Q‐in‐Q)    IEEE 802.1Q‐2005 Virtual LAN (VLAN)  bridges    IEEE 802.1v VLAN classification by  protocol and port    IEEE 802.3ac VLAN tagging    The switch shall support port‐based VLAN,  IEEE 802.1q tag‐based VLAN, IP subnet‐ based VLAN, protocol‐based VLAN, and  Private VLAN    LLDP‐MED ANSI/TIA‐1057 and Voice VLAN  d.  Routing Protocol    Support Black hole routing    Directed broadcast forwarding    DNS relay    Equal Cost Multi‐Path (ECMP) routing    Policy‐based routing    Route maps    Route redistribution (OSPF, BGP, RIP)    UDP broadcast helper (IP helper)    Up to eight Virtual Routing and  Forwarding (VRF Lite) domains (with  license)  e.  Security     Access control list, SSH, RADIUS, SSLv3,  MAC‐based authentication    Dynamic VLAN assignment, NAC, BPDU  Protection, Guest VLAN support, Web‐ based Authentication    Transport Layer Security (TLS) Extensions,  PPP Extensible Authentication Protocol  and IEEE 802.1x Multi Supplicant  authentication    DHCP snooping, IP source guard and  dynamic ARP inspection    DoS attack blocking and virus throttling    IEEE 802.1x Authentication protocols (TLS,  TTLS, PEAP & MD5), SSH Remote Login    IEEE 802.1x, MAC‐based and Web‐ based—can be enabled simultaneously on  the same port.    The switch shall support inbuilt scalable  RADIUS server.    The supplicants can be access to especial  server (ex. Active Directory) and be  authenticated properly before the switch  authenticates the port which the  supplicants connected.                                                                                                        The switch shall support be able to move  the users who are failed authentication to  arbitrary VLAN  f.  Multicast Support    The switch shall support IGMPv2, IGMPv3,  IGMPv2 snooping, and IGMPv3 snooping.    The switch shall support PIM‐SM and PIM‐ DM, MLD Snooping (v1 and v2)  g.  Quality of Service    Limit bandwidth per port or per traffic  class down to 64kbps    Wire speed traffic classification with low  latency essential for VoIP and real‐time  streaming media  applications    Policy‐based QoS based on VLAN, port,  MAC and general packet classifiers    Policy‐based storm protection    Extensive remarking capabilities    Strict priority scheduling, weighted round  robin or mixed    RED and WRED curves for drop  precedence    RFC 2474 DiffServ Precedence for 8  queues/port, RFC 2475 DiffServ  Architecture, RFC 2597 DiffServ Assured  Forwarding (AF) and RFC 3246 DiffServ  Expedited Forwarding (EF)  h.  Resiliency features    Stacking ports can be configured as 10G  Ethernet ports    Control plane prioritization ensures the  CPU always has sufficient bandwidth to  process network control traffic    Link Aggregation (802.3ad LACP),   Dynamic Link Failover, STP Root Guard    The switch shall be able to detection and  block the port automatically, in case of it  receive loop detection packets which itself  send at other port.       The switch is configured received rate‐ limit of broadcast, multicast and  unknown‐unicast packets. In case of it  received over setting value, discard excess  packets to prevent packet storm    IEEE 802.1D Spanning Tree Protocol (STP)  ‐ MAC Bridges, IEEE 802.1s Multiple  Spanning Tree Protocol (MSTP)                                                                                                i.            j.                          IEEE 802.1t ‐ 2001 802.1D maintenance  and IEEE 802.1w ‐ 2001 Rapid Spanning  Tree Protocol (RSTP)  Should Support Long‐distance stacking as  well Virtual Router Redundancy Protocol  (VRRP)  Support PVST+ compatibility‐mode  Stackable up to eight units in a VCStack  IPv6 Features  6to4 tunnelling  DHCPv6 relay, DNSv6, NTPv6  IPv4 and IPv6 dual stack  IPv6 management via Ping, TraceRoute,  Telnet and SSH  Neighbor discovery for IPv6  Management  SNMPV3, Web based GUI, Telnet, RMON  (4 groups) and command Line Interface.  Out of band 10/100/1000 Ethernet  management port , Console management  port  SD/SDHC memory card socket allowing  software release files, configurations and  other files to be  stored for backup and distribution to  other devices  Event‐based triggers allow user‐defined  scripts to be run upon selected system  events  The switch shall support IEEE 802.1ab Link  Layer Discovery Protocol (LLDP)  SSH and SNMPv3 for secure management,  Support RFC 2741 Agent Extensibility  (AgentX) Protocol  The switch shall support MIB‐II and RMON  MIB (groups 1, 2, 3, and 9) and Port  Mirroring  RFC 2575 View‐based Access Control  Model (VACM) for SNMP  RFC 2574 User‐based Security Model  (USM) for SNMPv3, RFC 1212 Concise MIB  definitions  RFC 1212 Concise MIB definitions, RFC  3164 Syslog Protocol, Diagnostic Tools  ,BIST (Built‐In Self Test)  The switch shall support sFlow: A method  for monitoring traffic in switched and  routed networks                                                                                            The switch shall support an editor  function to edit a configuration directly.  k.  Electrical Approvals and Compliances    EMC: EN55022 class A, FCC class A, VCCI  class A    Certification: UL, cUL, TUV    Safety :UL60950‐1, CAN/CSA‐C22.2 No.  60950‐1‐03,EN60950‐1, EN60825‐1,  AS/NZS 60950.1    RoHS Compliant  l.  Power Consumption    89 Watts or less   m.  Environmental Specifications    Operating Temperature Range: 0°C to  40°C    Storage Temperature Range: ‐30°C to  70°C    SM FO Module Operation Temperature ‐ 5°C to 70°C                                                  7.   L2 24 port Gigabit Managed Switches    Sl.  REQUIRED SPECIFICATION  a.  Port Density    24 10/100/1000 Mbps with minimum two  SFP combo ports and one console port.    2 nos. dedicated 1G ethernet Stack port  and Stack between switch within 100  Mtrs.    Wire speed non blocking architecture  b.  Performance    Switch fabric 80+ Gbps with upwards of  50Mpps of throughput for cctv video  traffic    64MB RAM    Up to 2048 VLAN ID    8,000 MAC address  c.  Interface support    10/100‐TX RJ‐45    10/100/1000TX RJ‐45    100‐FX, 1000‐SX, 1000‐LX SFP slot    RS232 RJ‐45 connector  d.  Management    Industry Standard CLI    Web Interface    Secure encrypted WEB and CLI  management with SSH v2 and SSL  OFFERED SPECIFICATION      REMARKS                                                                        e.      SNMP v3  General Features  Single IP address Stack management  Across Stack Link Aggregation, VLAN  configuration, Port Mirroring, Trunking  across stack    20 Gig Rissilance link between Stack  f.  Quality of Services    4 or more Priorities assigned to 4 queues    802.1p for Layer 2 QoS    DSCP (Diffserv) for Layer 3 QoS    802.1p to DSCP remarking traffic    Traffic prioritization using 802.1p, ToS,  DSCP fields    Strict Scheduling and Weighted Round  Robin  g.  Security    Guest/Private VLAN    SSHv2 for Telnet management    SSLv3 for WEB management    RFC 1492 TACACS+    RADIUS Authentication    IEEE 802.1x Port‐based network access  control    Broadcast Storm Control    MAC & IP based ACLs  h.  General Standards    802.1d Bridging    802.3x BackPressure/ Flow Control  i.  Redundancy Standards    802.1D Spanning Tree Protocol    802.1W Rapid Spanning Tree    802.1s Multiple Spanning Tree    802.3ad LACP Link Aggregation    Static port trunk    IGMP snooping v3  j.  VLANs    IEEE 802.1Q VLAN Tagging    Up to 256 VLANs    Port‐based VLANs    MAC‐based VLANs    Private VLANs    GARP VLAN Registration Protocol (GVRP)  k.  Power Characteristics    Voltage input 100‐ 240VAC  l.  Electrical/ Mechanical Approvals    Safety UL 1950 (UL/cUL), EN60950 (TUV)    EMI FCC Class A, EN55022 Class A,                                                                                                                                                                                        VCCI Class A, C‐Tick, EN61000‐3‐2,  EN61000‐3‐3  Immunity EN55024  RoHS compliant  Contractors must provide an OEM  authorization confirming the compliance  to above technical specifications, along  with the OEM authorization letter.                        8.   GSM Modem     Sl.  REQUIRED SPECIFICATION  OFFERED SPECIFICATION  a.  Certification   CE/FCC    Interface Type   USB  Style   External  Type  Wireless  Download  7.2 Mbps  Upload  2Mbps  MicroSD card slot  up to 8GB  Color  White/Black  3G Frequency  HSDPA/UMTS  Band   850/1900/2100MHz  2G Frequency  GSM/GPRS/EDGE  Band   850/900/1800/1900MHz Weight   About 30g  Dimension   69*26.5*12mm  Temp. storage   ‐20C ‐ +60C  Operation Temp   ‐10C ‐ +55C  Windows 2000/XP/Vista,  Compatible   Mac, and OS  REMARKS          9.   Storage Box     Sl.  REQUIRED SPECIFICATION  OFFERED SPECIFICATION    support  a.  The  storage  array  should  industry‐leading  Operating  System  platforms & clustering including: Windows  Server  2003,  Windows  Server  2008,  Sun  Solaris,  HP‐UX,  IBM‐AIX,  Linux,  Vmware&  Citrix Xen Server.  b.  Offered Array shall be scalable to at‐least    minimum  of  100  or  higher  numbers  of  Drives  80TB  or  higher  capacity  using  300GB/450GB/600GB, 15K drives.  c.  Every  offered  storage  node  /  Controller    shall  be  supplied  with  minimum  of  4  X  6  SAS Ports and 2 x 1Gbps/8 x 1 Gbps ISCSI  ports  and  shall  be  upgradable  to  10Gbps,  REMARKS        d.  e.  f.  g.  h.  i.  j.  k.  l.  m.  n.  o.  p.  if required.  Offered Controllers shall be active‐active .  Offered  Storage  Array  shall  be  supplied  with minimum of 3.6TB raw capacity using  300GB 15K capacity drive  Storage system shall have support of both  SAS  and  SATA  drives  like  300GB  SAS  and  1TB SATA drives.  Every  storage  node  /  Controller  shall  be  provided with minimum of 4GB memory.   Offered  Storage  array  shall  be  configured  in such a way that future capacity growth  shall  not  warrant  any  additional  software  license on the storage array.  Array  must  support  Automatic  Load  Balancing.  Offered  storage  array  shall  be  configured  in  a  no  single  point  of  failure  so  that  failure  of  storage  node  /  Controller  shall  not impact the operations.  Every  offered  storage  controller  shall  support RAID 10, 5 and 6 levels.  Storage  shall  be  offered  with  both  Snapshot  and  clone  license  for  the  complete capacity supported by the array  and  shall  not  warrant  any  additional  license  for  Snapshot  and  clone  in  future  due to capacity growth..  Clone  space  shall  be  equivalent  to  the  actual data in the Source volume.  Storage  shall  support  more  than  32  snapshots for a given volume.  Storage  shall  support  both  Synchronous  and  Asynchronous  based  replication  and  shall  be  supplied  with  required  licenses  for  complete  supported  capacity  of  the  array.  Storage  array  shall  be  supplied  with  performance management software.                                                      OFFERED SPECIFICATION    REMARKS      10.   Air Conditioner     Sl.  REQUIRED SPECIFICATION  a.  Star Rating  5  Capacity  (Tonnage)  1.5  Capacity (W)  5,300  Air Circulation  (Max,  ㎥/min)  16.0  Energy  Efficiency  EER  (Cooling,  W/W)  Moisture  removal (l/hr)  2.0  Noise level  Indoor  High/Low  .38  1          11.   Network Printer     Sl.  REQUIRED SPECIFICATION  a.  Functions   Print. copy, scan, digital send,  black/white fax (optional)  Multitasking supported  Yes  Printing specifications    Print speed black:  ISO Laser comparable:Up to 50  ppm  Normal:Up to 50 ppm  (All printed pages originate from  the default tray of a HP LaserJet  9040/9050mfp with a High‐ Capacity Input (HCI) Tray 4. )  First page out (ready)    Black:Less than 9.5 sec  Duty cycle (monthly, A4)  Up to 300,000 pages  Recommended monthly page  volume  15000 to 50000  Print technology  Monochrome Laser  Print quality black (best)  Resolution 1200 (1200 dpi quality),  600 x 600 dpi  Print languages  OFFERED SPECIFICATION    REMARKS     postscript level 3 emulation   direct PDF printing (v 1.3) with at  least 128 MB memory enabled   XHTML‐Print v 0.95   PML (Printer Management  Language); 80 internal scalable  TrueType fonts; additional font  solutions available    Display   Graphical touchscreen display  Processor speed  533 MHz  Connectivity    Connectivity, standard   Hi‐Speed USB 2.0, Gigabit Ethernet  Embedded Print Server, 1 open EIO  slot, connection for paper handling  device, host USB port (compatible  with USB 2.0 specifications) for  additional functionality, 1 Foreign  Interface Harness (FIH)  Network ready  Standard  Connectivity, optional   EIO internal print servers, external  print servers, Fast Infrared connect  (FIR): Connectivity: en1700 USB 2.0  Print Server J7988G, en3700 USB  2.0 Print Server J7942G, ew2400  Wireless USB 2.0 Print Server  J7951G, 510x Parallel Print Server  J7983G, 300x Parallel Print Server  J3263G, EIO 1284 adapter J7972G,  620n EIO print server J7934G, 635n  EIO Print Server J7961G, 630n EIO  Print Server J7997G 690n Wireless  print server J8007G  Minimumsystemrequirements  Microsoft® Windows® 2000: 300  MHz processor, 64 MB RAM;  Microsoft® Windows®  XP Home and XP Professional: 233  MHz processor, 64 MB RAM; 180  MB of free hard disk space for  Windows®, CD‐ROM drive or  Internet connection;  Mac OS X v10.2.8, v10.3, v10.4 or  higher with 128 MB RAM, CD‐ ROM, 160 MB of free hard disk  space. For Mac OS v10.4 and  higher, PowerPC and Intel® Core  Processor Macs are supported  Compatible operating systems   Microsoft® Windows® 2000   XP Home, XP Professional   Windows Vista® Ready   OS/2 v3.0 or higher   Mac OS X v10.2.8, v10.3, v10.4 or  higher   Linux   AutoCAD  Memory specifications    Memory, standard  384 MB  Memory, maximum  512 MB  Hard disk   Standard, 80 GB  Paper handling    Paper handling input, standard  100‐sheet multipurpose tray, two  500‐sheet input trays, 2000‐sheet  input tray, 100‐sheet automatic  document feeder, automatic two‐ sided printing  Paper handling output, standard  Choose one finishing output  solution: 3000‐sheet stacker, 3000‐ sheet stapler/stacker,  multifunction finisher, 2000‐sheet  8‐bin mailbox  Duplex printing   Automatic (standard)  Media sizes supported   A3, A4, A5, B4 (JIS), B5 (JIS), B6  (JIS), C5, DL  Media types  Paper (bond, colour, letterhead,  plain, preprinted, prepunched,  recycled, rough), labels, cardstock,  transparencies  Media weights, supported  Multipurpose tray 1: 64 to 216  g/m²; Tray 2, 3 and 4: 64 to 199  g/m²  Scanner specifications    Scanner type  Flatbed, ADF  Scan file format  PDF, JPEG, TIFF, MTIFF  Scan resolution, optical  Up to 600 dpi  Scan size (flatbed), maximum  27,9 x 43,2 cm  Automatic document feeder  capacity  Standard, 100 sheets  Digital sending standard features   Scan to e‐mail   Desktop folder   Network folder. LDAP addressing.  User Authentication: PIN   LDAP/Active Directory with  Kerberos  File formats, supported   PDF   JPEG   TIFF   MTIFF  Copier specifications    Copy speed (normal)  Black:Up to 50 cpm  Copy resolution (black text)  Up to 600 x 600 dpi  Copy reduce / enlarge settings  25 to 400%  Copies, maximum  Up to 999  Fax specifications    Faxing  Optional  Fax transmission speed  33.6 Kbps (with optional analog fax  accessory)  Fax note  Optional, enabled with purchase of  optional analog fax accessory  Fax memory  Dependent upon available disk  space  Fax resolution  Up to 300 x 300 dpi  Speed dials, maximum number  Up to 100  Broadcast locations  100  Power and operating requirements    Power  Input voltage 110 to 127 VAC (+/‐  10%), 50/60 Hz (+/‐ 2 Hz); 220 to  240 VAC (+/‐ 10%), 50/60 Hz (+/‐ 2  Hz)  Power consumption  1022 watts (active/printing), 1030  watts (copy), 331 watts (ready),  244 watts (sleep), 2 watts (off);  Typical Electricity Consumption  (TEC): 18.9 kWh/Week  (Power reported is highest values  measured for printing and copying  using all standard voltages.)  Operating temperature range  15 to 32.5° C  Operating humidity range  30 to 70% RH  Dimensions and weight    Minimum dimensions (W x D x H)  With 8‐bin mailbox: 1092 x 838 x  1219 mm, with stacker: 1168 x 787  by 1194 mm, with stapler/stacker:  1168 x 787 x 1194 mm, with  multifunction finisher: 1295 x 787 x  1194 mm  Weight  143 kg (without finishing output  solution)  Package weight  181.4 kg (without finishing output  solution)      12.   Sl.  a.  10 KVA UPS   REQUIRED SPECIFICATION  UPS Type  Double  Conversion  True On‐Line  b.  CAPACITY ‐ KVA  10 KVA  c.  Phase  Three  d.  Voltage  305 – 475 V  e.  Power Factor  0.9  f.  Frequency  45 Hz – 55 Hz  g.  Phase  Single  h.  Voltage / Regulation  230 V +/‐ 1%  i.  Nominal Frequency  50 Hz +/‐ 0.05 Hz  j.  Power Factor  0.8 p.f.  k.  Over Load  125%  for  10  Minutes  & 150% for 1 Minute  l.  Static Voltage Regulation  +/‐  6%  for  50%  step  load change  m.  Dynamic  Voltage  +/‐ 1% Nominal for all  Regulation  variations  of  Line  Load  +/‐  10%  for  10%  to  100%  step  load  change  n.  Wave From  Sinusodial  o.  Total  Harmonic  <3%  Distortion  p.  Inverter Efficiency  85%  to  93%  on  full  load  q.  Charger  Input  circuit  breaker,  Charger over voltage,  Charger  over  current  limit.  r.  Battery  Battery  low  cut  off  /  Current  limit,  HRC  fuse  in  battery  path,  Battery  over  charger  trip  s.  Inverter  Out  over  voltage  /  Over  load  trip,  Current  limit,  Short  circuit  OFFERED SPECIFICATION    REMARKS                                                                            t.  Main  ON,  UPS  ON,    UPS trip, UPS OV/UV,  Battery low trip  u.  Display  LCD  Display  for    Checking  Input  and  Output Parameters  v.  Operating  Temperature  0o to 55oC    Range  w.  Relative Humidity  95% non condensing    x.  Max.  Operating  altitude  3000 meters    without derating  y.  Acoustic Noise    <55db  z.  Back‐up Time  Min.  2  Hours  on  Full    Load    Indications                13.   Antivirus Software     Sl.  REQUIRED SPECIFICATION  OFFERED SPECIFICATION  detection,    a.  Real  time  virus  cleaning/quarantine.  b.  Heuristic  scanning  to  allow  rule‐based  detection  of  unknown  viruses  facility  of  Quarantine Manager  c.  Scanning  of  compressed  file  archives  in  ZIP,  ARJ  and  Microsoft  Compressed  formats.  d.  Protection  from  viruses  hiding  in  compressed  files,  such  as  Internet  downloads and email attachments  e.  Protection against spyware  f.  Proactive  protection  against  zero‐day  threats.  g.  Central  management  console  to  centrally  control  desktop  configurations,  including  scanning and cleaning options.  h.  Centralized  Audit  trail  logging  and  reporting  capability  with  ability  to  communicate the reports using email.  i.  Role based administration of the solution.  j.  Real‐time  lock  down  of  client  configuration  –  allow  or  prevent  users  from  changing  setting  or  unloading/uninstalling the software.  k.  Pattern  file  roll‐back  –  shall  be  able  to  return  to  past  pattern  file  if  there  is  any  problem with the new pattern file.  l.  Automatic  downloads  of  latest  virus  signature  updates  from  the  Internet  to  desktops  and  servers,  across  different  REMARKS                                                m.  n.  o.  p.  q.  r.  s.  t.  platform  running  Windows.  The  distribution  should  happen  seamlessly  from a single management console  Integration  with  Windows  Active  Directory.  Remote  deployment  of  Client  software  installation/Windows  2003/  2008  remote  installation.  Support  for  Windows  XP  Professional,  Windows  Vista,  Windows  7,  Windows  2003 Server, Windows 2008 Server  Ability to force an update (PUSH) to client  Application and Device control.  Support  for  additional  features  like  Desktop  Firewall,  Intrusion  Prevention  System etc.  Multiple  AV  server  management  and  AV  client syn.  Client  av  should  be  transfer  or  manage  another  AV  server  without  down  time  of  the system.                                    14.   Firewall     Sl.  REQUIRED SPECIFICATION  a.  The  Firewall  must  be  appliance  based  and  should  facilitate  multi‐application  environment.   It  should  be  modular  based  to  accommodate    future growth/ expansion  The  Firewall  should  be  ICSA  Labs  certified  for    ICSA  4.0  and  EAL  4  certified,  if  not  the  same  model  The  platform  should  be  based  on  realtime,    secure embedded operating system  The  platform  should  use  ASIC  based    architecture  that  is  optimized  for  packet  and  application level content processing  The  proposed  system  shall  support  unlimited    IP/User  license  for  Firewall  /  VPN  (IPSec&  SSL)/ IPS/WCF/AV  Should  provide  a  Http,  Https,  SSH,  Telnet,    SNMP  based  management  console  for  managing  and  configuring  various  components of the appliance   The  device  should  belong  to  a  family  of    products  that  attains  NSS  Approved  (UTM)  Certification  The  device  should  belong  to  a  family  of    products  that  attains  IPv6  Ready  Phase  2  &  IPv6 Certification  OFFERED SPECIFICATION    REMARKS                                    The  Firewall  Appliance  should  be  rack  mountable and shall not exceeding 2U  The  Firewall  should  have  facility  to  provide    Two  Factor  Authentication  solution  with  additional token based solution  The  Firewall  should  have  facility  to  provide    Wireless Controller to support wireless access  points for wi‐fi environment  b.  Networking  &  System  Performance  Requirements:  The Firewall should support a minimum of 10 ‐    10/100/1000  interfaces  with  auto  sensing  capacity  The  platform  should  support  the  standards    based  Link  aggregation  technology  (IEEE  802.3ad) to achieve higher bandwidth.  The Firewall should support IEEE 802.1q VLAN    Tagging with about 1024 VLANs supported (in  NAT/Route mode)  Should  support  automatic  ISP  failover  as  well    as ISP load sharing for outbound traffic  The  Firewall  should  support  Dynamic  Routing    Protocol  for  RIP1  &  2,  OSPF,  OSPFv3,  BGP4,  ISIS, RIPng  The  Firewall  should  support  Static,  Policy    Based, and Multicast routing  The  Firewall  should  support  throughputs  of    7.0 Gbps or better.  The  firewall  should  support  throughput  of    atleast4 Gbpsof AES ‐ IPSEC VPN.  should  support  concurrent  session    atleast20,00,000  Should  support  new  session  per  second    atleast 45,000   Should  support  and  IPS  throughput  of  1.2    GBPS or better  Should  support  and  GAV  throughput  of    upto500 Mbps  Should support Site to Site VPN Tunnels up to    5000  Should support firewall Policies up to 35,000    c.  Operating  System  &  Management  Requirements:  Be  proprietary  to  prevent  inheriting  common    OS vulnerabilities  Resided  on  flash  disk  for  reliability  over  hard    disk  Allow multiple OS firmware image for booting    options  Upgradeable via Web UI or TFTP    Be  easily  backup  or  restored  via  GUI  and  CLI    to/from  local  PC,  remote  centralized  management or USB disk                                                                                                     The  system  shall  support  profile  base  login  account  administration,  offering  gradual  access  control  such  as  only  to  Policy  Configuration & Log Data Access    The  proposed  system  shall  be  able  to  limit    remote  management  access  from  certain  trusted  network  or  host  with  corresponding  administrator account  The  proposed  system  should  be  able  to    facilitate  administration  audits  by  logging  detailed  activities  to  event  log  for  management & configuration updates  The  administrator  authentication  shall  be    facilitated  by  local  database,  PKI  &    remote  services  such  as  Radius,  LDAP  and  TACAS+  with option of 2 Factor Authentication  The  Firewall  must  be  capable  of  clustering    multiple  firewalls  together  into  a  redundant  and  highly  available  stateful  configuration  without any extra license cost for creating HA.  d.  Firewall Requirements:  The  Firewall  should  support  deployment    modes  as;  “Stealth  Mode”  or  “Route  Mode"  or "Transparent Mode” or "Proxy Mode".   The  proposed  system  should  have  integrated    Traffic Shaping / QoS functionality  The firewall shall be able to handle VoIP traffic    securely  with  “pinhole  opening”  and  support  SIP, SCCP, MGCP and H.323 ALGs  Should  support  DHCP  server  &  DHCP  Agent    functionality   The  Firewall  should  support  Stateful    inspection  with  optional  Policy  based  NAT  (Static OR Dynamic)  The  Firewall  should  support  Inbound  Port    Forwarding    with  optional  inbound  Load  Balancing  Should  support  IPv6  ACL  to  implement    security Policy for IPv6 traffic  All  internet  based  applications  should  be    supported  for  filtering  like  Telnet,  FTP,SMTP,  HTTP,  DNS,  ICMP,  DHCP,  RPC,SNMP,  BGP,  IMAP, NFS etc  Should be able to inspect HTTP and FTP traffic    when  these  are  deployed  using  non  standard  port( i.e when HTTP is not using standard port  TCP/80)  e.  High Availability Requirements:  The  firewall  must  support  Active‐Active  as    well as Active‐Passive redundancy.  The  Firewall  must  support  stateful  clustering    of  multiple  active  firewalls,  and  the  firewalls  must load balance the traffic between them to                                                                            share the load.  The  cluster  should  support  simple  and    minimal downtime during upgrade  f.  IPSEC VPN Requirements:  The  IPSEC  VPN  and  SSL  VPN  capability  shall    minimally  attain  Internet  Computer  Security  Association (ICSA) Certification or equivalent.  The  proposed  system  shall  comply/support    industry standards, L2TP, PPTP, IPSEC, and SSL  VPN  without  additional  external  solution,  hardware or modules:   The  device  shall  utilize    inbuilt  hardware  VPN    acceleration supported for:  IPSEC (DES, 3DES, AES) encryption/decryption    SSL encryption/decryption    The  system  shall  support  the  following  IPSEC    VPN capabilities:  Multi‐zone VPN supports.    IPSec, ESP security.    Supports Aggressive and Dynamic mode    Hardware accelerated encryption using IPSEC,    DES, 3DES, AES  Support  perfect  forward  secrecy  group  1  and    group 2 configuration  MD5  or  SHA1  authentication  and  data    integrity.  Automatic  IKE  (Internet  Key  Exchange)  and    Manual key exchange.  Supports NAT traversal    Supports Extended Authentication    Supports Hub and Spoke architecture    Supports Redundant gateway architecture    DDNS support    The  system  shall  support  IPSEC  site‐to‐site    VPN  and  remote  user  VPN  in  transparent  mode.  g.  SSL VPN Requirements:  The Firewall should be integrated solution and    there  should  be  no  user  based  licensing  for  SSL VPN.  The  Firewall  should  support  for  TWO  modes    of SSL VPN:  Web‐only  mode:  for  thin  remote  clients    equipped  with  a  web  browser  only  and  support  web  application  such  as:HTTP/HTTPS  PROXY, FTP, SMB/CIFS, SSH, VNC, RDP  Tunnel mode, for remote  computers that run    a variety of client and server applications  The system shall be capable of enforcing host    checking  prior  to  SSL  tunnel  mode  connections:  The  system  shall  provide  SSL  VPN  tunnel                                                                                                                    mode  that  supports  32  and  64‐bit  Windows  operating systems  The  proposed  solution  shall  allow    administrators  to  create  multiple  bookmarks  to add to a group and make these bookmarks  available for SSL‐VPN users.  h.  Network  Intrusion  Detection  &  Prevention  System Requirements:  The  IPS  capability  shall  minimally  attain    Internet Computer Security Association (ICSA)  NIPS/NSS Certification  Should have a built‐in Signature and Anomaly    based IPS engine on the same unit  Able  to  prevent  denial  of  service  and    Distributed Denial of Service attacks.  Signature  based  detection  using  real  time    updated database  Anomaly  based  detection  that  is  based  on    thresholds  Administrator  shall  be  able  to  configure  DoS    policies  that  are  used  to  associate  DoS  settings  with  traffic  that  reaches  an  interface  based  on  defined  services,  source  and  destinations IP/Range.  The device shall allow administrators to create    Custom IPS signatures  IPS  Signatures  can  be  updated  in  three    different  ways:  manually,  via  pull  technology  or  push  technology.  Administrator  can  schedule  to  check  for  new  updates  or  if  the  device has a public IP address, updates can be  pushed  to  the  device  each  time  an  update  is  available.  Configurable  IPS  filters  to  selectively    implement  signatures  based  on  severity,  target  (client/server),  protocol,  OS  and  Application types.  Supports  automatic  security  updates  directly    over  the  internet.  (ie  no  dependency  of  any  intermediate device)  Security check updates do not require reboot    of the unit.  Supports  attack  recognition  inside  IPv6    encapsulated packets.  Supports user‐defined signatures with Regular    Expressions.  Supports  several  prevention  techniques    including drop‐packet, tcp‐rst (Client, Server &  both) etc. List all prevention options  i.  Antivirus System Requirements:  The  Antivirus  capability  shall  minimally  attain    Internet Computer Security Association (ICSA)  AV Certification or equivalent                                                                                                    j.                  The proposed system should be able to block,  allow or monitor only using AV signatures and  file blocking based on per firewall policy  The  System  should  be  able  to  scan  following  Protocols:  HTTP and HTTPS  SMTP and SMTPS  POP3 and POP3S  IMAP  Instant  Messenger  (AIM,  YAHOO!,  MSN,  ICQ,  SIMPLE)  NNTP  The  proposed  system  shall  provide  ability  to  allow,  block  and  intercept  (allow  but  quarantine)  attachments  or  downloads  according to file extensions and/or file types  AV  Signatures  can  be  updated  in  three  different  ways:  manually,  via  pull  technology  or  push  technology.  Administrator  can  schedule  to  check  for  new  updates  or  if  the  device has a public IP address, updates can be  pushed  to  the  device  each  time  an  update  is  available.  The  AV  solution  shall  be  able  to  quarantine  blocked and infected files to either local hard  disk or externally.  The proposed system should be able to block  or  allow  oversize  file  based  on  configurable  thresholds  for  each  protocol  types  and  per  firewall policy.  The  solution  should  be  capable  scanning  Encrypted  VPN  tunnel  traffic  originating  from  the unit for virus  Web  &  Application  Content  Filtering  System  Requirements:  The  proposed  system  should  have  integrated  Web  Content  Filtering  solution  without  external  solution,  devices  or  hardware  modules.  URL database should have atleast 40 million +  sites and 75 + categories.  The  proposed  solution  should  be  able  to  enable  or  disable  Web  Filtering  per  firewall  policy or based on firewall authenticated user  groups for both HTTP and HTTPS traffic.  Should  blocks  web  plug‐ins  such  as  ActiveX,  Java Applet, and Cookies.  Shall include Web URL block  Shall include score based web keyword block  Shall include Web Exempt List  The  proposed  solution  should  be  able  to  replace  the  web  page  when  the  web  page  matches the Web Filtering blocking criteria.                                                                                                                        Should have the intelligence to identify &             k.  Data Leak Prevention Requirements:  Should  have  the  ability  to  prevent  data  loss          The  proposed  solution  shall  be  able  to  identify,  retrieve  and  rate  the  actual  URL  of  the  cache  content  commonly  available  in  search engines such as Yahoo and Google.  The  proposed  solution  shall  be  able  to  identify, retrieve and rate the image files from  image search engines. If belongs to a blocked  category, image will be replaced by a blank.   The  proposed  solution  shall  be  able  to  identify, retrieve and rate the multimedia files  from  multimedia,  video  &  Audio  search  engines.  If  belongs  to  a  blocked  category,  content  will  be  replaced  by  a  blank.  For  example,  a  YouTube  component  will  be  blanked while retaining the rest of the content  in a webpage.  The  solution  shall  allow  administrators  to  create  multiple  new  local  URL  filtering  categories besides dynamic categories  The  solution  shall  allow  administrators  to  override  Online  URL  Database  ratings  with  local settings  Many  web  sites  use  HTTP  redirects  legitimately;  however,  in  some  cases,  redirects  may  be  designed  specifically  to  circumvent  web  filtering,  as  the  initial  web  page  could  have  a  different  rating  than  the  destination  web  page  of  the  redirect.  The  solution shall be able to rate redirected sites.  The solution shall be capable of rating URLs by  domain  and  IP  address  which  sends  both  the  URL  and  the  IP  address  of  the  requested  site  for  checking,  providing  additional  security  against attempts to bypass the rating system.                Should have application control feature     control of popular IM & P2P applications like KaZaa,BitTorrent etc. Should have minimum database of 1500 types of application awareness   through SMTP, FTP, HTTP, HTTPS & IM  Should have built in pattern database                  15.   Furniture and Fixture   Sl.  REQUIRED SPECIFICATION  a.  OFFERED SPECIFICATION    2.5  Ft  X  4  FT  Tables  with  Cabinets  and  REMARKS    b.  c.   d.  e.  f.    16.   keyboard  Tray  (Made  of  Board,  sandmica)  5  nos.  Should  be  customised  based on site conditions.  Chairs  revolving  10  nos  with  high  back,  leather finish.  6u  wall  mount  Rack  to  store  the  switches./ network accessories.  Steel  Cupboards  4  nos  required  to  store  records made of high quality CRCA steel.  Other  works  as  directed  by  the  department  based  on  requirement  within  the Control Room.  Laying  of  all  cables  and  accessories  to  connect  all  systems.  (Cabling  will  include  all Network and Electrical Cabling)                      Command and Control Software     Sl.  REQUIRED SPECIFICATION  OFFERED SPECIFICATION  a.  The  Central  Control  Station  is  the    nerve  centre  of  the  ITS  system.  Polling  and  receiving data from and to the vehicles in the  field  from  the  Automatic  Vehicle  Location  Information sub‐system are its main functions.  Central  control  station  shall  be  housed  in  a  premises identified by the purchaser (MUDA).  The  geographical  information  system  (GIS)  application shall enable display of the position  of vehicles on a detailed digitized road map of  Shillong  and  linked  with  the  communication  control and reporting applications.  The  central  control  station  applications  that  will  be  web  enabled  shall  provide  for  appropriate user access and security controls.  The  GIS  system  shall  provide  for  color  coded  on  arrival  times  of  buses  at  various  bus  stations  Automatic Vehicle Location / Tracking  Location  of  different  buses  in  its  fleet  at  Shillong.  The  tracking  and  locating  the  buses  will cover those buses in movement.  Ability to locate a bus at given time in its track  to  estimate  its  arrival/departures  time  at  the  next  destination,  based    on  traffic  density,  distance,  speed,  bus  occupancy,  run‐time  information from the previous bus arrival time  for the same location etc.  Facility  to  track  defined  vs.  actual  movement  of vehicles.  Facility  to  view  vehicle  movements  real‐time  REMARKS    on digital on digital maps.  Facility to generate information such as travel  time  destination,  average  time  at  bus  stop,  number of passengers boarding at each point,  density  of  passenger  traffic  at  different  bus  stops  enroute,  passengers  traffic  at  different  location,  alerts  on  exceptions,  and  logging  of  the journey details of the bus for each trip.  Support  tracking  of  buses  that  deviate  from  the  scheduled  route  based  on  definition  of  permitted geographic regions of operation.  Facility  for  playing  back  the  recorded  details  of  the  bus  movement  along  the  authorized  Route.  Vehicle  Fleet  Summary  Dashboard  –  Quick  view on fleet performance.  The system will be customised with the above  options  and  also  with  certain  other  MIS  reports required by the Management.      17.   Digital Video Recorder(DVR)   Sl.  REQUIRED SPECIFICATION  OFFERED SPECIFICATION  a.   Multiple  levels  of  video  quality,  CIF  (352x288)  to  full    (704x576) selectable for each channel of videos   Total resource: 4 channel full D1   Anti‐vibration,  anti‐shock  mounted  case  and  hard  drive  carrier for maximum reliability   Real time (25/30 frames per second) on every channel   Lockable, removable hard disk drive   Short  leading  distance  for  HDD  (hard  disk  drive)  case  installation   Software  option  for  easy  search  and  review  of  incidents(when required)   The recording should be carried out with time, date and  this should be visible while reviewing the recording.   Software  For  Easy  review,  backup  of  video  recorded  on  DVR hard drive   Password Protection   Self‐contained  aluminum  die‐case  enclosed  to  protect  from dust and moisture, IP56   Wide Operating temperature range   Ultra low power consumption when in standby mode   Should allow to take the  backup data  at the end of the  day   Software  option  for  live  view  and  tracking  the  vehicle  location   Support  wireless  video  data  downloading,  WIFI  IEEE802.11n   File  system  on  the  HDD  shall  be  Protected  from  Unauthorized access or modification   Backup  battery    support  at  least  10  minutes  normal  recording when bus power was cut off  REMARKS     Support GPS    Network System Video Audio Built-in Modules Optional Built-in GPS、WCDMA、WIFI Module, G-sensor Language English Operating Linux/Android system Video input 4 CH Video output 1 CH RCA Signal NTSC/ PAL system Audio input 4 CH Audio ADPCM compression Video D1/HD1/CIF resolution 2.5 inch 1TB hard disk LocalOne SD card, max storage 32GB Alarm input 6 CH Alarm output 2 CH GPS 3G WIFI GPS module WCDMA / EVDO 802.11b/g/n 1 RJ45 Ethernet Network interface Serial interface Speed interface USB2.0 Power input Power & Power output Consumption Consumption Extended Interface G-sensor General Dimension Weight Operating temperature interface 1 RS232 & 2 RS485 1 Speed sensor 1 DC8V ~ 36V 4 channel DC12V 2A 12W-30W Built-in G-sensor module 220mmx166mmx70mm 2.5kg -25℃ ~ +85℃                 18.   Dome Camera    Sl.  REQUIRED SPECIFICATION  OFFERED SPECIFICATION  REMARKS  a.  Image Sensor CMOS, PC1089 System PAL/NTSC     Horizontal 600TVL Resolution Minimum Color:0.1Lux /F1.2 Illumination Effective PAL:512(H)×582(V) Pixels NTSC:510(H)×492(V) S/N Ratio More than 48dB Gamma AGC White Balance 0.45 Auto Auto Day &NightIR Cut AUTO Switch Electronic Shutter Video Output BLC Sensing Area Sync System IR Distance Lens Power Supply Operation Temp. Dimension Weight 1/50(60)~1/100,000 sec 1.0Vp-p/75Ω on/off 4.9mm*3.7mm Internal 10-15m, 24pcs Ф5 IR LED 3.6 / 6 mm Lens DC12V -10℃~50℃ 94mm(Φ)×80mm 390g     19.   Reverse Gear Camera  Sl.  REQUIRED SPECIFICATION    Aluminium  Shell  Waterproof  IR  Color  CCD  Camera    Image Type: 1/3 Color SHARP CCD    Horizontal Resolution: 420 TV Lines    Effective Pixel: NTSC: 510(H)X492(V);  PAL:500(H)X582(V)    Useable Illumination: 0Lux (Built in 18pcs IR  LED’s for picture Support in the dark    Free viewing angle: 1300    Waterproof: IP66    Shockproof: 10G    Video Output: 1.0Vp‐p75Ω    Automatic Heating Below + 100C  OFFERED SPECIFICATION    REMARKS                                            Power Supply: DC12V from Reversing Monitor    Dimensions: 69 (W) x 43(H) x 38(D) mm    (without mounting)        20.   Announcement System with Internal Display  Sl.  REQUIRED SPECIFICATION  OFFERED SPECIFICATION  a.  The  announcement  System  comprises  of    Amplifiers  and  speakers  units.  These  are  mounted  inside  the  bus  for  next  bus  stop  &  destination  announcements  meant  for  passengers  inside  and  outside  the  bus.  There  are  two  independent  audio  inputs.  The  audio  signal  for  these  is  delivered  by  the  Controller  unit by text to voice conversion.    The  Controller  unit  drives  the  integrate  voice  announcement  System  –  both  inside  &  outside  the  bus.  The  controller  unit  has  two  independent  audio  output  ports.  The  audio  output  signals  from  these  ports  are  given  to  the amplifiers for driving the speakers.    The  controller  unit  also  maintains  a  database  of  announcement  messages.  It  outputs  suitable  announcement  message  to  the  respective  speakers  at  requisite  time  for  making the announcement. The Audio output  is  transmitted  to  various  speakers  mounted  inside  and  outside  the  bus  on  two  independent  channels  –  one  for  speakers  mounted on external display boards and other  mounted inside the bus.    Specification of Speakers:  2  Nos  4  watts  for  internal   Display  unit  which  will  be  controlled  by  the  Driver  Control  Unit  to  display  information  based on announced information.    The display shall automatically display the bus  stop name and produce audio announcement  when the bus reaches a particular stop based  on the signal derived from DCU.  REMARKS      21.   Driver Information System (DIS/DCU  Sl.  REQUIRED SPECIFICATION  a.  Features of the Driver Console Unit (DCU)  User friendly user interface with 7” TFT  touch screen  Password based user authentication for  driver  Secure data communication with central  OFFERED SPECIFICATION    REMARKS    server over GPRS and Wi‐Fi  Interface with Can bus and camera  Support LED displays on 485 Port or  Ethernet  Automatic stage change facility based on  GPS with line‐out facility for voice  announcement  Synchronize ETM over serial  communication  Advertisement module to generate  revenue  Alert module to display various public  alerts/ warnings  Read video content from DVR  and display  it on Screen for drivers reference.    b.   Compatibility with ticketing machine:  Receive and transmit transaction to back  officeControl Passenger information  systems (LED signs and Voice  announcement)  Automatic announcement of stop & next  stop  Interface vehicle tracking Device  Transmit GPS Location of Bus and Route  Number data to back office for Vehicle  Tracking,  Driver Bus Route Guidance  1GB memory  USB Host Port, RS232C port, RS485 ports,  CAN port, Wi‐Fi  Support Hindi and English language  display  Works on Bus Battery  c.  The Controller unit interfaces with following    devices  On Board Display  Voice Announcement Device  Vehicle Tracking Device  On Board Camera  Electronic Ticketing machine (thru Wi‐ Fi/Bluetooth)  The System integrates all JnNURM buses  plying in the city with central control  station, Bus stand and Bus terminals.        22.   LED Display Front/Rear  Sl.  REQUIRED SPECIFICATION  a.  LED based Display system as per  dimensions of the bus to display data from  the Control Unit . These Display units will be  placed in front and rear of the bys to display  bus number and route details.    OFFERED SPECIFICATION    REMARKS    23.   Cables and Accessories   Sl.  REQUIRED SPECIFICATION  a.  OFFERED SPECIFICATION  accessories     All  Cables  and  required  to  connect  devices  within  the  BUS .  REMARKS      24.   System Integration   Sl.  REQUIRED SPECIFICATION  a.  OFFERED SPECIFICATION  System Integration will be the one    REMARKS    time  job  to  be  performed  where  by  integrating the entire Hardware with the  help  of  software  customised  as  per  requirement  to  meet  all  the  requirements  to  run  the  system  efficiently.      25.   Web Site (    Sl.  REQUIRED SPECIFICATION  a.  OFFERED SPECIFICATION  of    Design  and  development  Website  for  Passengers  and  tourists  whish  can  later  be  upgraded  to  a  dynamic site. Some of the Key features of  the Website :‐   Information portal.   Feedback System   Search Options   Booking Options   Bus Schedules and Routes.  REMARKS      26.   Service/Support and Manpowerper month    Sl.  REQUIRED SPECIFICATION  a.  OFFERED SPECIFICATION    This  will  include  providing  live  REMARKS    support  for  systems  installed  at  Control  Room and on buses.   Adequate  and  skilled  manpower  for running  complete systems at Control  Room .    27.   Add‐on Battery    Sl.  REQUIRED SPECIFICATION  a.  Add‐on Battery – 12V, 80AH    OFFERED SPECIFICATION    REMARKS    28.   Multiplex Wiring System    1. Multiplex Wiring System Parameters  Status,' Fault  list’, Voltage, Current, and 'diagnostic'  of  all External and Internal lamps, ITS equipment ,  Passenger/driver, Compartment illumination, Ventilation, defroster, motors, valves, Kneeling automation,  CNG, Solenoids, Speed Limiter,  Fans,  Buzzer, Horn ,  Doors  Sensors  & Fuel/Coolant  Levels/Pressures  and such parameters as related to 'Driving Habits' for the purpose of improving  operational efficiency.    2. Safety Critical vehicle Systems such as Braking, door locking, Tyre behaviour.    3. Engine  • Engine CAN  • Engine oil Pressure,   • Engine Coolant temperature,  • Engine Speed in RPM,  • Vehicle Speed, Engine % load (Torque),   • Diagnostic message (Engine Specific)    4. Transmission  • Transmission CAN  • Transmission Output Shaft Speed  • Transmission Input Shaft Speed  • Transmission Current Gear  • Transmission Oil Filter Restriction Switch  • Transmission Oil Life Remaining  • Transmission Service Indicator  • Transmission Sump Oil Temperature  • Transmission Oil Level High / Low  • Hydraulic Retarder Oil Temperature  • Accelerator Pedal  • Diagnostic message (Transmission  Specific)    5. Diesel Bus Electronics Data  • Drivers Demand of Engine Torque Percentage  • Actual Engine Torque Percentage  • Engine And Retarder Torque  • Engine Speed  • Source Address Controlling Device  • Engine Starter Mode  • Engine Demand Torque Percentage  • Accelerator Pedal 2 Low Idle Switch  • Road Speed Limit Status  • Accelerator Pedal Kickdown Switch  • Accelerator Pedal Low Idle Switch  • Accelerator Pedal Position  • Percent Load At Current Speed• Remote Accelerator Pedal Position  • Accelerator Pedal Position 2  • Vehicle Acceleration Rate Limit Status  • Engine Temperature  • Engine Coolant Temperature  • Fuel Temperature  • Engine Oil Temperature  • Turbo Oil Temperature  • Engine Intercooler Temperature  • Engine Intercooler Thermostat Opening  • Engine Fluid Level Pressure  • Fuel Delivery Pressure  • Extended Crankcase Blow By Pressure  • Engine Oil Level  • Engine Oil Pressure  • Crankcase Pressure  • Coolant Pressure  • Coolant Level    29.   Test Standard Compliance Document  These Tests Standard Compliances are common to PIS Controllers / Multiplexing nodes / Single Controller  / Displays  Offered Specifications  Sl No.  Test Standards Compliance  1  Performance Parametric test    2  Cold    3  Dry Heat    4  Damp Heat    5  Vibration‐Standard AIS 012/AIS:062‐10g    6  Dust and Water Ingress Protection    7  Free fall    8  ESD Protection    9  Fire Resistant    10  Reverse polarity protection without  fuse    11  Over Voltage protection  12  Short Circuit protection  13  Insulation Resistance  14  Cranking Voltage  Note: To ensure service life requirements and  functionality. The component shall run for 60 minutes  at alternate voltage system, without effecting the  service life or function.  Note: All Infotainment components shall be able to  withstand a Short‐circuit or overload on all external  outputs without resulting in thermal damage to the  component or its interfaces. All external outputs shall  be over current and short‐circuit protected.    Note: The components shall have an electrical energy  reserve that can handle voltage drop during cranking.  Component shall not reset during cranking.   15  Load Dump Test on Controller    16  Salt Spray Test    17  EMC    18  Operating Parameters      30.     31.   Critical DTC messages for PIS Signs  Sl No.  Description  1  Overvoltage  2  Low Voltage  3  Overheat  Critical Error messages for PIS Signs  Description  Sl No.  Hardware Revision  1  Serial Number  2  Boot Loader SW Revision  3  Application SW Revision  4  Front Library Revision  5  CPU part number  6  CPU Qualification  7  CPU temperature range  8  Compilation of FW date and time  9  Flash Update status  10  Test date and time  11  Article number sign level  12  Production date  13  End Customer  14  Order number  15  Bus/Vehicle type  16  Bus builder number (bus build)  17  Language  18  Board temp sensor  19  Internal CPU temp  20  Min temp CPU  21  Max temp CPU  22  Max temp board  23  Min temp board  24  Max Input poer voltage  25  Min Input poer voltage  26  Operating hours  27  Number of resets  28  32.     33.   Diagnostic Trouble Codes  Comments  Sl No.  1  Watchdog reset  2  Low voltage reset  3  Lost communication, GPS satellite (GPS receiver is not available to the system)  4  GPS antenna error  5  USB, Invalid USB Mass Storage device  6  USB, Unknown USB device connected  7  USB, USB invalid File system  8  USB, overcurrent  9  Overvoltage  10  Low Voltage  11  Overheat  Parameter IDs  Description  Sl No.  1  Hardware revision  2  Serial number  3  Bootloader SW revision  4  Application SW revision  5  Font library revision  6  CPU part number  7  CPU qualification  8  CPU temperature range  9  Compilation of FW date and time  10  Test date and time                TENDER FORM (To be signed and submitted by Bidder)  From  M/s.___________________  _______________________  _______________________  _______________________  _______________________  To  The Secretary,  Meghalaya Urban Development authority,  Parking Cum Shopping Complex  Police Bazar, shilling – 793001    Sub:  ‐  Supply,  Installation  and  Maintenance  of  Intelligent  Tracking  System  (ITS)  components  for  Buses  under JnNURM of the Ministry of Urban Development.    Dear Sirs,    I/We hereby offer to carry out and complete the work referred to above in accordance with the enclosed  schedule  of  work,  specifications  and  such  other  details  as  may  be  supplied  from  time  to  time  by  the  MUDA  (Purchaser) or its authorized representative at the rate offered by me/us in the schedule. I/we further undertake to  complete the work in 30 days from the date of acceptance of the work order.    Should this tender be accepted, I/We hereby agree to abide by and fulfill all the terms and provisions of the  conditions of the contract annexed here to.    We confirm that we have not been disqualified by any Govt. Dept. / PSU for supply of Supply, Installation  and Maintenance of Intelligent Tracking System (ITS) components. Should it be found that our Company / Firm was  under  disqualification  prior  to  filling  up  this  tender,  we  will  be  subject  to  immediate  disqualification  and  our  Earnest Money Deposit / security Deposit is likely to be forfeited. Also we understand that in such eventuality, the  purchaser, is liable to cancel the award / Letter of intent / Purchase order (if given to us). Further, Earnest Money  Deposit (EMD)/ Security Deposit, in full value of which is to be absolutely forfeited to MUDA, should I/We fail to  complete the work specified.    We  hereby  undertake  to  provide  Performance  Security  equivalent  to  10%  of  the  value  of  the  Invoice  amount with a validity period of three years (renewable for a further period as per requirement) OR MUDA may  retain the EMD & SD to be released after three years (or afterwards as per requirement).      Place:                   Yours faithfully,  Date:                        Signature of the bidder with seal                PRICE SCHEDULE FORMS Note: In information systems procurement, the Contract Price (and payment Schedule) should be linked as  much as possible to achievement of operational capabilities, not just to the physical delivery of technology.    General  1. The Price Schedules are divided into separate Schedules as follows:  a. Grand Summary Cost Table  b. Supply and Installation Cost Summary Table  c. Recurrent Cost Summary Table  2. The Schedules do not generally give a full scope of the information technologies to be supplied, installed, and  operationally accepted, or the Services to be performed under each item. The quoted rates and prices shall be  deemed to cover the full scope of these Technical Requirements, as well overhead and profit.  3. The  Schedule  does  not  cover  costs  to  be  incurred  by  means  of  rental  for  usage  of  connectivity  methods  like  Lease Line/Rental for GSM networks for sending messages/Internet Usage Charges.  SL  PARTICULARS  QTY  A/U  RATE  CONTROL ROOM           1  72" LCD Display  2 Nos     2  Server  4 Nos     3  Windows Server 2012 DC  2 Nos     4  Desktop Computer  8 Nos     5  24 Port Core Switch  1 Nos     6  24 Port distribution switch  1 Nos     7  24 Port GBIC Switch Managed L2   1 Nos     8  GSM Modem  4 Nos     9  Storage box  2 Nos     10  Air Conditioner   2 Nos     11  Network Printer   1 Nos     12  10 KVA UPS   1 Nos     13  Antivirus Software Corporate for 4 Server    1 Nos     14  Firewall  2 Nos     15  Furniture and Fixture  1 Job     16  Command and Control Software  1 Nos     17  Software Licence (CAL) Per Bus per month  120 Nos     18  TOTAL ( 1 to 17)  19  VAT/CST on SL 18  20  TOTAL WITH TAX (18+19)  21  Installation and Commissioning   1 Job     22  SERVICE TAX ON (21)  23  TOTAL WITH SERVICE TAX (21+22)                 AMOUNT                  BUS           24  Digital Video Recorder(DVR)  120 Nos     25  Dome Camera  240 Nos     26  Announcement System with internal Display  120 Nos     27  Driver Information System  120 Nos     28  Software Licence per month (GPS,DMS,AS)  120 Nos     29  LED Display Front  120 Nos     30  LED Display Rear  120 Nos     31  Cables and Accessories  120 Nos     32  Add‐on Battery  120 Nos  33  Reverse Camera  120 Nos     34  TOTAL ( 24 to 33)  35  VAT/CST on SL 34  36  TOTAL WITH TAX (34+35)  37  Installation and Configuration  120 Job     38  SERVICE TAX ON (37)  39  TOTAL WITH SERVICE TAX (37+38)  OTHERS           40  System Integration  1 Job     41  Web Site  1 Nos     42  Service/Support and Manpower per month  1 Month    43  TOTAL(40 to 42)     44  SERVICE TAX ON (43)     45  TOTAL WITH SERVICE TAX (43+44)  GRAND TOTAL            Rupees___________________________________________________________________________Only.    The Prices are inclusive of All Duties and Taxes.  The Prices are valid for a period of 120 days from the date of deposit of this tender.    AMC @ ________For First Year  AMC @________For Second Year  AMC @________For Third Year.     AMC @________For Fourth Year  AMC @________For Fifth Year.                 Name of Bidder: Authorized Signature of Bidder: