Transcript
SHM 105 Gooseneck Microphone
SHM 105 F
Order # 484.008
SHM 105 M
Order # 725.064
Condenser gooseneck microphone. Length 500 mm. Plug-in type. With lockable female XLR connector. With rigid tube.
Condenser gooseneck microphone. Length 500 mm. Plug-in type. With male XLR connector. With rigid tube.
TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS
Transducer type . . . . . . . . . . . . . . . . Condenser (electret) Operating principle. . . . . . . . . . . . . . Pressure gradient Frequency response Close miking . . . . . . . . . . . . . . . . . . 50 - 16,000 Hz Distant miking (distance 1m) . . . . . . 350 - 16,000 Hz Polar pattern . . . . . . . . . . . . . . . . . . Cardioid Sensitivity . . . . . . . . . . . . . . . . . . . . . -36.5 dBV ±3 dB Nominal impedance . . . . . . . . . . . . . 200 Ω Load impedance. . . . . . . . . . . . . . . . 1 kΩ Max. SPL . . . . . . . . . . . . . . . . . . . . . 119 dB [SPL @ 1% THD] Signal-to-noise-ratio . . . . . . . . . . . . . 68 dB [A] Equivalent SPL . . . . . . . . . . . . . . . . . 26 dB[A] Connector . . . . . . . . . . . . . . . . . . . . 3-pin XLR (female) Capsule diameter with pop shield. . . approx. 25 mm without pop shield . . . . . . . . . . . . . approx. 14 mm Gooseneck diameter . . . . . . . . . . . . 6-9 mm Total length . . . . . . . . . . . . . . . . . . . 510 mm Weight . . . . . . . . . . . . . . . . . . . . . . . approx. 195 g
Transducer type . . . . . . . . . . . . . . . . Condenser (electret) Operating principle. . . . . . . . . . . . . . Pressure gradient Frequency response Close miking . . . . . . . . . . . . . . . . . . 50 - 16,000 Hz Distant miking (distance 1m) . . . . . . 350 - 16,000 Hz Polar pattern . . . . . . . . . . . . . . . . . . Cardioid Sensitivity . . . . . . . . . . . . . . . . . . . . . -36.5 dBV ±3 dB Nominal impedance . . . . . . . . . . . . . 200 Ω Load impedance. . . . . . . . . . . . . . . . 1 kΩ Max. SPL . . . . . . . . . . . . . . . . . . . . . 119 dB [SPL @ 1% THD] Signal-to-noise-ratio . . . . . . . . . . . . . 68 dB [A] Equivalent SPL . . . . . . . . . . . . . . . . . 26 dB[A] Connector . . . . . . . . . . . . . . . . . . . . 3-pin XLR (male) Capsule diameter with pop shield. . . approx. 25 mm without pop shield . . . . . . . . . . . . . approx. 14 mm Gooseneck diameter . . . . . . . . . . . . 6-9 mm Total length . . . . . . . . . . . . . . . . . . . 510 mm Weight . . . . . . . . . . . . . . . . . . . . . . . approx. 170 g
FREQUENCY RESPONSE & POLAR PATTERN This frequency response curve (measuring tolerance ±3 dB) and polar pattern correspond to a typical production sample for this microphone. Frequency response curve ±3 dB
SHM 105 F / SHM 105 M
1 of 1 beyerdynamic GmbH & Co. KG Theresienstr. 8 | 74072 Heilbronn – Germany Tel. +49 (0) 71 31 / 617 - 0 | Fax +49 (0) 71 31 / 617 - 199
[email protected] | www.beyerdynamic.com For further distributors worldwide, please go to www.beyerdynamic.com Non-contractual illustrations. Contents subject to change without notice. E1 / SHM 105 (12.14)
0 dB = 15 mV/Pa