Transcript
Memory Configurations and Population Order:
D E
CPU 1 Socket
Note location of alignment notch. Insert DIMM making sure the connector edge of the DIMM aligns correctly with the slot. Push down firmly on the DIMM until it snaps into place and both levers close. IMPORTANT! Visually check that each latch is fully closed and correctly engaged with each DIMM edge slot.
E
SCU 0
Front Panel
SCU 1*
(Optional:Please check your chassis user guide)Attach active heatsink fan power cable to server board as shown.
Note: See Intel Remote Management Module 4 documentation for detail information.
Install the RMM4-Lite Module on to the 7-pin connector on the server board labeled as “RMM4-LITE”
A
Attach the RMM4 Dedicated Server Management NIC module to the add-in card bracket as shown.
B
Install the RMM4 Dedicated Server Management NIC in an add-in card slot near the server board RMM4 header.
SATA 1** SATA 0** SATA 5
Server Board
Server Board
AF004475
USB
C
B
14 Ribbon Cable
Return to your Intel® Server Chassis Quick Start User's Guide, or your non-Intel chassis documentation to finish installation and configuration of your Intel® Server Board S2400SC.
A
C
Attach the RMM4 ribbon cable. Make sure each connector end is securely seated.
Latch
CPU 2 Socket
Return to this document to finish up, including software, BIOS, drivers and operating system installation.
RMM4 Server Board Header
System Fan 1-6 Connector Detail
For a non-Intel server chassis, see the documentation accompanying your chassis for specific chassis fan connection requirements. Refer to the "Making Connections to the Server Board - Quick Reference" section below.
d
ar
Bo AF004475
• BIOS, Drivers, and Operating System Installation
A. Confirm BIOS Version:
Look on the Server/System Management screen in the BIOS Setup Utility to determine the installed BIOS version. Compare this to the versions at: http://www.intel.com/support/motherboards/server. If new versions are available, update the BIOS on your server. See the Techinical Product Specification on the Intel® Server Deployment Toolkit CD for update instructions. Use the instructions provided
C. Install your Operating System:
With the operating system running, insert theIntel® Server Deployment Toolkit CD. If using a Microsoft Windows* operating system, the Intel® Deployment Assistant will autorun and allow you to select the appropriate drivers to install. On other operating systems, browse the CD folders to locate and install the driver files.
Intel® Server Chassis P4000M
S
M O
U
Serial B
N
Storage Upgrade Key
eUSB SSD
W
SAS/SATA
Intel® Server Chassis P4000S
CPU 2 Socket
Q
Intel® Server Chassis P4000M
2
J1C4
3
Default Enabled
Main Power
With hot swap backplane only
With hot swap backplane only
Y
With redundant power supply only With hot swap backplane only
With redundant power supply only With hot swap backplane only
AB
HDD LED
X
HSBP_I2C
Power LED
BIOS Recovery 2 J1C5 3
Default Recover
HDD LED
SYS FAN_7
Power Button
CPU 1 Socket
Storage Upgrade Key
Sys Fan 6 Sys Fan 5 Sys Fan 4
SATA SGPIO
V
F
E
J2C6
3
ME Force Update
2
J2J2
3
BIOS DFLT
2
Default Clear
CPU 2 Socket
SATA 1 SATA 0
J2J3
3
Default Enabled
Default Password Clear
Main Power
J2H1
Sys Fan 1
SM Bus Chassis Intrusion NIC 2 Link/Activity
Password 2 Clear
Battery
2
H Sys Fan 2 G Sys Fan 3
Reset Button ID Button Temp Sensor
HDD LED
TPM
I
ID LED System Status NIC 1 Link/Activity
CPU 2 Power
RMM4 LITE
HDD LED Header
AA PMBus IPMB
SCU 1
RMM4 NIC eUSB SSD
2
Serial A
NMI
SATA 5
USB 6
P
DIMM_A1
With hot swap backplane only
T
USB 4/5
VGA
SATA 2 SATA 3 SATA 4
R B
NIC1 USB1 USB0
CPU 2 Fan Serial B
SCU 0
BMC Force Update
SATA
With hot swap backplane only
NIC2 USB3 USB2
Front Panel
C
Front Panel Header (J1C3)
ID LED Status LED Diagnostic LED
Front Panel
USB 4/5
DIMM_B1
M. Serial B N. Storage Upgrade Key(Optional) O. USB 4/5 P. IPMB Q. SAS/SATA R. SATA S. RMM4 Lite T. HDD LED 2. For a non-Intel chassis, U. RMM4 NIC see your chassis documentation for server board connection information. V. SATA SGPIO W. eUSB_SSD X. TPM Y. USB 6 Z. LCP AA. PMBus AB. HSBP 12C
RMM4 NIC
DIMM_C1
Optional Connections
Intel® Server Chassis P4000M
With fixed fan only With hot swap fan only With hot swap fan only With hot swap fan only With hot swap fan only
D. System Fan 6 Header E. System Fan 5 Header F.System Fan 4 Header G.System Fan 3 Header H.System Fan 2 Header I.System Fan 1 Header J.System Fan 7 Header K.CPU Fan 1 Header L.CPU Fan 2 Header
A
Intel® Server Board S2400SC Component Layout
DIMM_A1
Intel® Server Chassis P4000S
CPU 2 Power
CPU 2 Fan
Sys Fan 7
DIMM_F2
CPU/System Fan Connections
L
J
RMM4 Lite
DIMM_C2
Notes: 1. All optional connections are not shown in this diagram. Refer to the Reference section of this Quick Start User's Guide, your Intel® Server Board Service Guide, and your server chassis documentation for additional connection information.
Intel® Server Chassis P4000S
A. CPU 1-2 Power Connector B. Main Power Connector C. Front Panel Header
DIMM_F1
IMPORTANT NOTE: Cables should be tied for better airflow. Use cable-ties compulsorily.
Required Connections
DIMM_E1
Making Connections to the Server Board Quick Reference
Video
Up-to-date firmware, driver and utility information
DIMM_B1
USB 0 USB 2 USB 1 USB 3
Software and Drivers
Additional Reference documents available at: http://www.intel.com/support/motherboards/server
D. Install Operating System Drivers:
Serial A
Tested peripherals and operating systems list Tested memory list Supported processors list
DIMM_C2
5
lot_
e_s
PCI
Use the instructions provided with the RAID controllerand with the operating system.
Sever Configurator Tool
DIMM_F2
with the RAID controller.
The system does not boot or show video at power-on: • Check that all processor power connectors are plugged-in. Without these connections, the server cannot boot. • Beep code 3 means you have bad memory; replace the faulty DDR3 DIMM(s). • Remember, all DIMMs must be: – DDR3 800/1066/1333/1600-compliant, 240-pin DIMMs. – No mixing of DDR3 RDIMMs and UDIMMs. – Installed from first slot of each channel. The system sometimes works, but is exhibiting erratic behavior. • This is probably the result of using an underrated power supply.
DIMM_F1
B. Configure your RAID Controller:
Technical Product Specification In-depth technical information Technical information and issues update Monthly Specification Update Spares, Parts List, and Configuration Guide Supported accessories and spares list
DIMM_E1
Add-
NIC2 NIC1 10/100/ 10/100/ 1000 Mb 1000 Mb
For a list of hardware components that have been tested with this system, see: http://www.intel.com/p/en_US/support/server/
Content
Slot 6 ( PCI e Gen 3)
d in Car
Network
Common Problems and Solutions
Available Documents Document/Tool
DIMM_D1
See your chassis documentation for AC power and grounding requirements.
DIMM_C1
Before installing your operating system, you must finish your chassis installation, make I/O connections and plug in AC power.
CAUTION: See your chassis documentation for AC power and grounding requirements.
Software
Slot 5 ( PCI e Gen 3)
For the Intel® Server Chassis P4000 series, see the Quick Installation User's Guide accompanying the chassis.
17
Finishing Up
Slot 4 ( PCI e Gen 3)
See the documentation that come with your server chassis for add-in card installation.
16
Slot 3 ( PCI e Gen 2)
CAUTION: Please ensure proper card holding mechanism is used in the chassis when instert add-in cards onto PCIe slot 5.
Slot 2 ( PCI 32)
Install Add-in Card[s]
DIMM_D1
15
D
HSBP_I2C LCP TPM
USB 6
CPU 1 Socket
IPMB
CPU 1 Fan
Z
K
LCP
CPU 1 Power
A
PMBus
System Fan 7 Connector Detail
CPU 1 Socket
er
Note: See your chassis documentation for detail information.
** 6Gb/s SATA port.
Chassis Fan Connections
IMPORTANT NOTE:
rv
SATA 4 SATA 3 SATA 2
R ConMM4 nec Lite tor
Y
Note: The server board is capable of supporting additional chipset embedded SAS and RAID options from the SCU controller when configured with one of several available Intel® RAID C600 Upgrade Keys, See Product Specification for the varies of options that different keys support.
Se
Note: * Available with Storage Upgrade Key installed.
_KE
A I R F L O W
Dedicated Server Management NIC
®
PG
CPU 2 Heat Sink
CPU 1 Heat Sink
USB Connector Detail
USB
B
E
Securely re-tighten each fastener again in the same order as performed in Step C.
Management Module 4-Lite
Note: For a non-Intel chassis, see your chassis documentation for intrusion switch requirements.
Serial B
A I R F L O W
t
Internal USB/Serial Connector Detail
TIM
Using a #2 Phillips* screwdriver, finger-tighten each fastener diagonally, according to the white-circled numbers.
R_U
See the documentation that came with your server chassis for drive installation.
13a (Optional) Install Intel® Remote 13b (Optional) Install Intel® RMM4 with
and USB Connections
Connect SAS/SATA Data Cables to server board here.
1
STO
on
Drive to Server Board
2
Server Board
(Optional) Install Intel® Storage Upgrade Key
Install the Intel® Storage Upgrade Key onto a 4-pin connector on the server board labeled “STOR_UPG_KEY”
Fr
12 Attach Front Panel, Serial,
B
Align the heat sink fins to the front and back of the chassis for correct airflow. Airflow goes from front-to-back of chassis.
10
Install Optical Drive and HardDrive(s)
sis
B
A
11 Connect Hard Drives/Optical
C D
D
9
CAUTION: Do not over-tighten fasteners.
A
C
E
If a protective film covers the thermal interface material (TIM) on the underside of the heatsink, remove the protective film.
3
CD
as
DIMM C2 C1 B1 A1
B
Note: Heatsink styles may vary
Ch
Memory sizing and configuration is supported only for qualified DIMMs approved by Intel®. For a list of supported memory, see the tested memory list at: http://serverconfigurator.intel.com/ default.aspx
Open both DIMM socket levers.
Install Heat Sink(s)
ow Fl
A B C
Note: For additional memory configurations, see the Techinical Product Specification for Intel® Server Board S2400SC at: http://www.intel.com/support/ motherboards/server
DIMM D1 E1 F1 F2
A
CAUTION: Avoid touching contacts when handling or installing DIMMs.
Memory Type: Minimum of one 1GB, DDR3 800/1066/1333/1600 MHz ECC UDIMM/RDIMM.
CPU 2 Socket
8
To Install DIMMs:
r Ai
Side 2
Install DIMM Memory Modules ... continued
SYS FAN_1 SYS FAN_2 SYS FAN_3
SYS FAN_6 SYS FAN_5 SYS FAN_4 SATA_SGPIO
CPLD Update
2
J2J4
3
Default Enabled
CPU 1 Fan CPU 1 Power
See your Intel® Server Board Service Guide for expanded component and connection information.