Preview only show first 10 pages with watermark. For full document please download

Side 2 9 10 12 17 15 13a 13b 14 16

   EMBED


Share

Transcript

Memory Configurations and Population Order: D E CPU 1 Socket Note location of alignment notch. Insert DIMM making sure the connector edge of the DIMM aligns correctly with the slot. Push down firmly on the DIMM until it snaps into place and both levers close. IMPORTANT! Visually check that each latch is fully closed and correctly engaged with each DIMM edge slot. E SCU 0 Front Panel SCU 1* (Optional:Please check your chassis user guide)Attach active heatsink fan power cable to server board as shown. Note: See Intel Remote Management Module 4 documentation for detail information. Install the RMM4-Lite Module on to the 7-pin connector on the server board labeled as “RMM4-LITE” A Attach the RMM4 Dedicated Server Management NIC module to the add-in card bracket as shown. B Install the RMM4 Dedicated Server Management NIC in an add-in card slot near the server board RMM4 header. SATA 1** SATA 0** SATA 5 Server Board Server Board AF004475 USB C B 14 Ribbon Cable Return to your Intel® Server Chassis Quick Start User's Guide, or your non-Intel chassis documentation to finish installation and configuration of your Intel® Server Board S2400SC. A C Attach the RMM4 ribbon cable. Make sure each connector end is securely seated. Latch CPU 2 Socket Return to this document to finish up, including software, BIOS, drivers and operating system installation. RMM4 Server Board Header System Fan 1-6 Connector Detail For a non-Intel server chassis, see the documentation accompanying your chassis for specific chassis fan connection requirements. Refer to the "Making Connections to the Server Board - Quick Reference" section below. d ar Bo AF004475 • BIOS, Drivers, and Operating System Installation A. Confirm BIOS Version: Look on the Server/System Management screen in the BIOS Setup Utility to determine the installed BIOS version. Compare this to the versions at: http://www.intel.com/support/motherboards/server. If new versions are available, update the BIOS on your server. See the Techinical Product Specification on the Intel® Server Deployment Toolkit CD for update instructions. Use the instructions provided C. Install your Operating System: With the operating system running, insert theIntel® Server Deployment Toolkit CD. If using a Microsoft Windows* operating system, the Intel® Deployment Assistant will autorun and allow you to select the appropriate drivers to install. On other operating systems, browse the CD folders to locate and install the driver files. Intel® Server Chassis P4000M S M O U Serial B N Storage Upgrade Key eUSB SSD W SAS/SATA Intel® Server Chassis P4000S CPU 2 Socket Q Intel® Server Chassis P4000M 2 J1C4 3 Default Enabled Main Power With hot swap backplane only With hot swap backplane only Y With redundant power supply only With hot swap backplane only With redundant power supply only With hot swap backplane only AB HDD LED X HSBP_I2C Power LED BIOS Recovery 2 J1C5 3 Default Recover HDD LED SYS FAN_7 Power Button CPU 1 Socket Storage Upgrade Key Sys Fan 6 Sys Fan 5 Sys Fan 4 SATA SGPIO V F E J2C6 3 ME Force Update 2 J2J2 3 BIOS DFLT 2 Default Clear CPU 2 Socket SATA 1 SATA 0 J2J3 3 Default Enabled Default Password Clear Main Power J2H1 Sys Fan 1 SM Bus Chassis Intrusion NIC 2 Link/Activity Password 2 Clear Battery 2 H Sys Fan 2 G Sys Fan 3 Reset Button ID Button Temp Sensor HDD LED TPM I ID LED System Status NIC 1 Link/Activity CPU 2 Power RMM4 LITE HDD LED Header AA PMBus IPMB SCU 1 RMM4 NIC eUSB SSD 2 Serial A NMI SATA 5 USB 6 P DIMM_A1 With hot swap backplane only T USB 4/5 VGA SATA 2 SATA 3 SATA 4 R B NIC1 USB1 USB0 CPU 2 Fan Serial B SCU 0 BMC Force Update SATA With hot swap backplane only NIC2 USB3 USB2 Front Panel C Front Panel Header (J1C3) ID LED Status LED Diagnostic LED Front Panel USB 4/5 DIMM_B1 M. Serial B N. Storage Upgrade Key(Optional) O. USB 4/5 P. IPMB Q. SAS/SATA R. SATA S. RMM4 Lite T. HDD LED 2. For a non-Intel chassis, U. RMM4 NIC see your chassis documentation for server board connection information. V. SATA SGPIO W. eUSB_SSD X. TPM Y. USB 6 Z. LCP AA. PMBus AB. HSBP 12C RMM4 NIC DIMM_C1 Optional Connections Intel® Server Chassis P4000M With fixed fan only With hot swap fan only With hot swap fan only With hot swap fan only With hot swap fan only D. System Fan 6 Header E. System Fan 5 Header F.System Fan 4 Header G.System Fan 3 Header H.System Fan 2 Header I.System Fan 1 Header J.System Fan 7 Header K.CPU Fan 1 Header L.CPU Fan 2 Header A Intel® Server Board S2400SC Component Layout DIMM_A1 Intel® Server Chassis P4000S CPU 2 Power CPU 2 Fan Sys Fan 7 DIMM_F2 CPU/System Fan Connections L J RMM4 Lite DIMM_C2 Notes: 1. All optional connections are not shown in this diagram. Refer to the Reference section of this Quick Start User's Guide, your Intel® Server Board Service Guide, and your server chassis documentation for additional connection information. Intel® Server Chassis P4000S A. CPU 1-2 Power Connector B. Main Power Connector C. Front Panel Header DIMM_F1 IMPORTANT NOTE: Cables should be tied for better airflow. Use cable-ties compulsorily. Required Connections DIMM_E1 Making Connections to the Server Board Quick Reference Video Up-to-date firmware, driver and utility information DIMM_B1 USB 0 USB 2 USB 1 USB 3 Software and Drivers Additional Reference documents available at: http://www.intel.com/support/motherboards/server D. Install Operating System Drivers: Serial A Tested peripherals and operating systems list Tested memory list Supported processors list DIMM_C2 5 lot_ e_s PCI Use the instructions provided with the RAID controllerand with the operating system. Sever Configurator Tool DIMM_F2 with the RAID controller. The system does not boot or show video at power-on: • Check that all processor power connectors are plugged-in. Without these connections, the server cannot boot. • Beep code 3 means you have bad memory; replace the faulty DDR3 DIMM(s). • Remember, all DIMMs must be: – DDR3 800/1066/1333/1600-compliant, 240-pin DIMMs. – No mixing of DDR3 RDIMMs and UDIMMs. – Installed from first slot of each channel. The system sometimes works, but is exhibiting erratic behavior. • This is probably the result of using an underrated power supply. DIMM_F1 B. Configure your RAID Controller: Technical Product Specification In-depth technical information Technical information and issues update Monthly Specification Update Spares, Parts List, and Configuration Guide Supported accessories and spares list DIMM_E1 Add- NIC2 NIC1 10/100/ 10/100/ 1000 Mb 1000 Mb For a list of hardware components that have been tested with this system, see: http://www.intel.com/p/en_US/support/server/ Content Slot 6 ( PCI e Gen 3) d in Car Network Common Problems and Solutions Available Documents Document/Tool DIMM_D1 See your chassis documentation for AC power and grounding requirements. DIMM_C1 Before installing your operating system, you must finish your chassis installation, make I/O connections and plug in AC power. CAUTION: See your chassis documentation for AC power and grounding requirements. Software Slot 5 ( PCI e Gen 3) For the Intel® Server Chassis P4000 series, see the Quick Installation User's Guide accompanying the chassis. 17 Finishing Up Slot 4 ( PCI e Gen 3) See the documentation that come with your server chassis for add-in card installation. 16 Slot 3 ( PCI e Gen 2) CAUTION: Please ensure proper card holding mechanism is used in the chassis when instert add-in cards onto PCIe slot 5. Slot 2 ( PCI 32) Install Add-in Card[s] DIMM_D1 15 D HSBP_I2C LCP TPM USB 6 CPU 1 Socket IPMB CPU 1 Fan Z K LCP CPU 1 Power A PMBus System Fan 7 Connector Detail CPU 1 Socket er Note: See your chassis documentation for detail information. ** 6Gb/s SATA port. Chassis Fan Connections IMPORTANT NOTE: rv SATA 4 SATA 3 SATA 2 R ConMM4 nec Lite tor Y Note: The server board is capable of supporting additional chipset embedded SAS and RAID options from the SCU controller when configured with one of several available Intel® RAID C600 Upgrade Keys, See Product Specification for the varies of options that different keys support. Se Note: * Available with Storage Upgrade Key installed. _KE A I R F L O W Dedicated Server Management NIC ® PG CPU 2 Heat Sink CPU 1 Heat Sink USB Connector Detail USB B E Securely re-tighten each fastener again in the same order as performed in Step C. Management Module 4-Lite Note: For a non-Intel chassis, see your chassis documentation for intrusion switch requirements. Serial B A I R F L O W t Internal USB/Serial Connector Detail TIM Using a #2 Phillips* screwdriver, finger-tighten each fastener diagonally, according to the white-circled numbers. R_U See the documentation that came with your server chassis for drive installation. 13a (Optional) Install Intel® Remote 13b (Optional) Install Intel® RMM4 with and USB Connections Connect SAS/SATA Data Cables to server board here. 1 STO on Drive to Server Board 2 Server Board (Optional) Install Intel® Storage Upgrade Key Install the Intel® Storage Upgrade Key onto a 4-pin connector on the server board labeled “STOR_UPG_KEY” Fr 12 Attach Front Panel, Serial, B Align the heat sink fins to the front and back of the chassis for correct airflow. Airflow goes from front-to-back of chassis. 10 Install Optical Drive and HardDrive(s) sis B A 11 Connect Hard Drives/Optical C D D 9 CAUTION: Do not over-tighten fasteners. A C E If a protective film covers the thermal interface material (TIM) on the underside of the heatsink, remove the protective film. 3 CD as DIMM C2 C1 B1 A1 B Note: Heatsink styles may vary Ch Memory sizing and configuration is supported only for qualified DIMMs approved by Intel®. For a list of supported memory, see the tested memory list at: http://serverconfigurator.intel.com/ default.aspx Open both DIMM socket levers. Install Heat Sink(s) ow Fl A B C Note: For additional memory configurations, see the Techinical Product Specification for Intel® Server Board S2400SC at: http://www.intel.com/support/ motherboards/server DIMM D1 E1 F1 F2 A CAUTION: Avoid touching contacts when handling or installing DIMMs. Memory Type: Minimum of one 1GB, DDR3 800/1066/1333/1600 MHz ECC UDIMM/RDIMM. CPU 2 Socket 8 To Install DIMMs: r Ai Side 2 Install DIMM Memory Modules ... continued SYS FAN_1 SYS FAN_2 SYS FAN_3 SYS FAN_6 SYS FAN_5 SYS FAN_4 SATA_SGPIO CPLD Update 2 J2J4 3 Default Enabled CPU 1 Fan CPU 1 Power See your Intel® Server Board Service Guide for expanded component and connection information.