Siemon Versapod® Data Center Solutions

   EMBED


Share

Transcript

8 SIEMON VersaPOD ® Data Center Solutions WWW.SIEMON.COM 8 IT IS ALL ABOUT USING YOUR SPACE WISELY There’s a ton to consider in the data center infrastructure, but physical space is always near the top. How will you fit everything you need today? What happens when you have more to add tomorrow? As equipment density grows, so grows the volume of data and power cables in your cabinets. You need a way to fit it all and do it in a way you can efficiently manage. 1 Just about all cabinets have 45U of horizontal mounting space and should, in theory, all support the same amount of equipment. But, traditional cabinets cannot fully utilize this space and cable management is the major limiting factor. You can’t fully populate a cabinet with equipment if you can’t realistically fit and manage the necessary cabling. Short of expanding your data center and adding more partially utilized cabinets, what is the solution? 8 MAKING SPACE. . . BY CONVERTING “WASTED” VERTICAL SPACE Siemon's VersaPOD cabinet system enables a completely new and efficient approach to your physical data center infrastructure. By leveraging the vertical space between bayed cabinets and at the end of row for Zero-U patching, cable management and power distribution, VersaPOD frees critical horizontal equipment mounting space for equipment and provides a dedicated, high capacity and easily managed cabling zone. 2 8 Zero-U Cable Management caBle acceSS POintS Multiple openings in the lid allow efficient cable routing access. An open floor design enables a high-capacity pathway for under-floor conveyance configurations. Vertical caBle ManageMent traYS Installed between bayed cabinets, these vertical managers help secure and route high cable-counts, converting internal vertical space into a large-volume cable management zone. caBle ManageMent FingerS Vertical 4- or 6-inch cable management fingers can be mounted alongside each Zero-U vertical space to facilitate routing of cords between equipment and patching fields as well as cabinet to cabinet connections. Optional hinged covers snap onto the cable management fingers to conceal and protect cable pathway for improved aesthetics. 3 DeDicateD caBling HigHwaYS Creating nearly 178mm (7”) of width between bayed cabinets and 191mm (7.5”) between equipment mounting rails and doors at the front and rear, the VersaPOD recessed corner post design creates accessible, high-capacity vertical and horizontal cabling highways – eliminating cable routing constraints associated with standard cabinet designs. Zero-U cable Management Benefits Getting cable out of the cabinet’s heavily congested equipment mounting space and into high-capacity vertical cabling zones drives benefits across your data center infrastructure, both for today and into the future. DenSitY - VersaPOD’s extra vertical space gives you the room to deploy ultra high-density data center infrastructures without sacrificing malleability of both cabling and equipment and maintaining the overall neatness and aesthetics of the facility. ZerO-U Vertical caBle ManageMent cHannelS Feature an array of integrated cable management options to offer a high capacity, easily accessible and concealable pathway for cable routing and slack management, without consuming or obstructing access to critical equipment space. Eliminates the need for obstructive, difficult to maintain cable management add-ons such as equipment-mounted swing-arms. enD-OF-rOw caBle ManagerS Mount vertically between the cabinet’s corner posts and side panels to provide additional Zero-U cable management zones at each end-of-row or stand-alone cabinets. ScalaBilitY - The high capacity of VersaPOD’s Zero-U cable management zones not only leave significant space to add cabling channels as your needs grow, it frees space needed to mount future networking equipment without the need to add more cabinets and consume valuable data center floor space. FlexiBilitY - VersaPOD’s wide variety of cable routing options enable it to support nearly any data center configuration, giving you the flexibility to design an infrastructure to fit your needs instead of working around the space limitations of traditional cabinets. acceSSiBilitY - With your cabling channels in their own dedicated space between the cabinets, you can perform ongoing moves adds and changes and gain unobstructed access to your equipment - less time in the cabinets and more on your strategic goals. 4 8 Zero-U Patching DUal-HingeD SPlit DOOrS Rear split doors can be hinged open in both directions or removed, providing direct and unimpeded access to either the vertical patching zones or equipment areas. ZerO-U Vertical PatcH PanelS Vertical copper and fiber patch panels provide up to 24U of Zero-U vertical patching space between every two cabinets (12 front, 12 rear) - up to 1152 copper and 1728 fiber ports. These panels conveniently slide forward providing access to the connections at the rear of the panel. receSSeD cOrner POStS 191mm (7.5”) of space between equipment ports and cabinet doors enables cables to be routed directly from Zero-U patch panels, cable managers or PDUs to equipment mounting areas. Also facilitates horizontal cabinet-to-cabinet cablerouting and patching. 5 Zero-U Patching Benefits SHOrter cOrDS anD JUMPerS - Zero-U patch panels put patching ports right beside equipment ports - reducing the need for more expensive, longer cords. Shorter cords and a more direct path improves air flow, aesthetics and simplifies channel tracing. MOre DeSign OPtiOnS - With your patching fields maintained in VersaPOD’s Zero-U vertical space, you can decrease or even eliminate the use of patch panels in traditional 19” horizontal mounting space freeing this space for additional networking and storage equipment options. ScalaBilitY - Supporting up to 1152 copper and 1728 fiber patching ports between every 2 cabinets and at both ends of each row, VersaPOD provides ample patching capacity for future expansion - without labor-intensive re-design or additional cabinets. HigH-caPacitY HOriZOntal caBle ManagerS 2U and 4U horizontal managers are available with 4” and 6” depths to effectively create horizontal cable management highways across a row of cabinets for cabinet-to-cabinet cable routing and patching while hinged covers conceal and protect the cable pathway. enD-OF-rOw Vertical PatcH PanelS Mount up to 8U of (4 front, 4 rear) patch panels in the Zero-U vertical space at both ends of each row. 6 8 EFFICIENCY & THERMAL MANAGEMENT With energy costs continuing to rise, Siemon’s VersaPOD system has been designed to control air flow to maximize Vertical exHaUSt DUct (chimney) Passively directs the hot exhaust heat from active equipment vertically into the return air space to increase HVAC efficiency. Can be field extended to a range of ceiling heights. thermal management and efficiency without sacrificing equipment and cabling density. PrOPer caBle ManageMent By moving cables out of the horizontal equipment mounting areas and away from equipment cooling fans, VersaPOD improves overall airflow and cooling efficiency. OPen FlOOr acceSS Each VersaPOD unit has a completely open base, enabling maximum air flow and routing of cabling into or out of raised floor pathway systems. OPtiOnal acceSSOrieS Each VersaPOD unit includes provisions for roof mounted cooling fans and additional accessories such as brush guards, blanking panels and grommets to promote proper air flow and temperature control. 7 Vertical caBle ManageMent traYS Up to 8 trays can be installed between each set of bayed cabinets to isolate air flow from cabinet to cabinet while facilitating routing and slack management of cabling. HigH-FlOw DOOrS Front and rear doors enable over 71% airflow to ensure proper hot aisle/cold aisle circulation. Split rear doors require smaller opening clearance, maximizing user access in shallow hot aisles. cOOling DOOrS VersaPOD transition frames available for mounting of liquid-cooled rear door heat exchangers from the Vette Corporation (Coolcentric™) and U-Systems (Coldlogik™). 8 VersaPOD THERMAL CAPACITIES Analysis Overview: This analysis is based on a third-party thermal capacity study of the VersaPOD cabinet using CFD modeling and uses the following parameters: - A single VersaPOD was fully populated with 1U/500W servers - A perforated floor tile placed in front of the cabinet provides an air output of 55°F, 600CFM - Servers were evenly removed until equipment intake temperatures met manufacturer requirements Temperature 140˚F /60˚C 122˚F /50˚C 104˚F /40˚C 86˚F /30˚C 68˚F /20˚C 50˚F /10˚C AnAlysis #1: sTAndArd Versapod cAbineT AnAlysis #2: Versapod wiTh VerTicAl exhAusT ducT & fAns - 1000mm (40”) VersaPOD cabinet - Perforated front and rear doors - No fans or vertical blanking panels installed - Blanking panels are used in horizontal locations where equipment is not present - 1200mm (48”) VersaPOD cabinet - Perforated front doors - Solid rear doors - Vertical exhaust duct - 3 fan trays installed in top of cabinet (9 fans total) - Blanking panels are used in horizontal locations where equipment is not present (14) servers installed within limits of intake temperatures (14) x 500W = 7kw capacity (26) servers installed within limits of intake temperatures (26) x 500W = 13kw capacity 8 8 MORE USABLE SPACE = MORE DESIGN OPTIONS While the VersaPOD’s innovative design offers unique features to improve the efficiency and manageability of all common data center environments and configurations, its greatest benefit may be its versatility. By making use of space wasted by traditional cabinets, VersaPOD opens the cabinet to design options not possible before. Whether you take advantage of its extra capacity to save floor space, plan for future scalability or leverage it’s Zero-U cable management and patching capabilities to get your physical layer under control- with VersaPOD you have the ability to design the infrastructure you really need. sample Versapod design options netwOrk caBinetS SerVer/StOrage For high density switching applica- VersaPOD’s optional Zero-U patch tions, VersaPOD’s optional Zero-U panels can be mounted on the rear of cable managers, in conjunction with the cabinets to provide connection 2U and 4U cable managers, can points in close proximity to servers. readily support high volume patch This allows for the use of shorter cord routing between switches and patch cords which can be better patch panels. All while providing a managed. professional appearance. Note that optional management fingers and associated hinging covers can be used to optimize the finished appearance. Alternate ZeroU channels can be used to mount PDU’s for power connections. patch cords power cables 9 8 FEWER CABINETS = LESS DATA CENTER REAL ESTATE = $ SAVINGS Two bayed VersaPODs provide an additional 40U of space vs. standard cabinets - nearly the equivalent of three standard cabinets in the space of two. The table below compares two VersaPOD’s to three standard cabinets, showing how VersaPOD can save 12” (304mm) of valuable data center floor space with every two cabinets. Scaled across all the cabinets in your facility, a significant space savings is possible. # of Cabinets Cabinet Width Space consumed Mounting Space VersaPOD 2 30” (762 mm) 60” (1524 mm) 130U Standard 600mm 3 24” (609.6 mm) 72” (1828 mm) 135U 12” (304 mm) Floor Space savings 8 VersaPOD SPACE SAVINGS EXAMPLE The diagrams below indicate a real-world example of how VersaPOD cut a customer’s cabinet needs in half. StanDarD caBinetS VerSaPOD • 4 Standard 600mm cabinets • 1 Fiber switch installed in each cabinet • Fiber enclosures and cable management required to support switches consumes the full equipment mounting space • 2 VersaPOD cabinets • 2 Fiber switches installed in each cabinet • All fiber connectivity and management requirements contained in the Zero-U space between bayed cabinets 10 8 MORE FEATURES & BENEFITS Two sizes VersaPOD is available in both 1000mm (40”) and 1200mm (48”) depths to accommodate all popular equipment types and configurations. Adjustable mounting rails support for pre-engineered cabling CEA 310E Standard mounting rails are adjustable to fit a wide array of network and storage equipment up to 1000mm (40”) in depth. VersaPOD’s cable management features are designed to leverage the installation and maintenance benefits of Siemon’s pre-terminated copper and fiber trunk cable assemblies and plug and play fiber solutions - enabling a consistent, modular and rapidly-deployed approach to both new installations and future data center expansion. Multiple keyhole mounting options and cage nuts further extend the ability to customize the VersaPOD to user requirements. integrated Grounding VersaPOD is available with custom grounding bars for fast and efficient management of equipment and cabling grounding requirements. removable side panels Provides open access to cabinet interior and end-of-row vertical cable management zone. Also simplifies installation and integration of additional cabinet units as the data center expands. simplified power distribution Standard, 19” rack-mount PDUs may be mounted in VersaPOD’s Zero-U vertical spaces for orderly routing and management of equipment power cords. 11 8 VersaPOD ® ORDERING INFORMATION caBinet BaSe Unit caBinet DOOrS anD PanelS VP(X)-(X)(X)(X)(X)11 Dimensions 1 = 1000 mm (40”) x 760 mm (30”), 45U Black 2 = 1200 mm (48”) x 760 mm (30”), 45U Black Side Panels Lock 1 = Keyed Lock 2 = Tumbler Combination Lock 0 = No Side Panels 1 = 1 Side Panel 2 = 2 Side Panels Front Door A = Full Vented/Dual Handle B = Split Vented/Dual Handle C = Split Solid/Dual Handle Rear Door A = Full Vented/Dual Handle B = Split Vented/Dual Handle C = Split Solid/Dual Handle Part # Description VP-DRA . . . . . . . . . . . . . . . .Full vented door, dual handle with standard keyed lock VP-DRB . . . . . . . . . . . . . . . .Split vented door, dual handle with standard keyed lock (2 doors required to close front or rear of single cabinet) VP-DRC . . . . . . . . . . . . . . . .Split solid door, dual handle with standard keyed lock (2 doors required to close front or rear of single cabinet) VP-S . . . . . . . . . . . . . . . . . .Locking Side Panel (standard keyed lock) Includes: 4 leveling feet, 50 cage nuts and 4 stabilizing brackets ZerO-U SliDing Vertical PatcH PanelS Part# Vertical exHaUSt DUct (cHiMneY) Description VP-VPP-TMRIC......................Sliding Vertical Copper/Fiber Combo Patch Panel 96 Ports, supports all category 5e and category 6 UTP MAX and Z-MAX, category 6A shielded Z-MAX outlets, TERA® outlets an MAX fiber adaptors. (Not for use w/Z-MAX 6A UTP) 6 fiber RIC adaptor mounting spaces for mounting RIC adapter plates or fiber plug and play modules VP-VPP-TM...........................Sliding Vertical Copper Patch Panel 96 Ports, supports all category 5e category 6, category 6A UTP MAX and Z-MAX outlets, category 6A shielded Z-MAX, TERA outlets and MAX fiber adaptors (Port spacing compatible with Z-MAX 6A UTP) Part # Description VP-DUCT1 . . . . . . .VersaPOD Vertical Exhaust Duct, 523mmx653mmx516-923mm (20.6x25.7x20-36 in.), Black VP-VPP-TMRIC VP-VPP-TM VP-VPP-6U VP-VPP-6U............................Sliding Vertical Bracket for any Standard 19” Rack Mount Products Mounts up to (6) 1U panels in Zero-U vertical orientation NOTE: 2 Vertical Panels or Brackets can be mounted vertically at the front and/or rear of 2 bayed cabinets. VP-DUCT2 . . . . . . .VersaPOD Vertical Exhaust Duct, 523mmx653mmx912-1320mm (20.6x25.7x36-52 in.), Black NOTE: Chimney compatible with 1200mm (48”) VersaPOD VP2 cabinets only. Solid doors recommended for use with chimneys. 12 8VersaPOD ® ORDERING INFORMATION enD-OF-rOw Vertical PanelS Part # Description VP-VWM . . . . . . . . . . . . . . . .Vertical Wire Manager Panel, end-of-row VP-VPP-2U . . . . . . . . . . . . . .Vertical Bracket for standard 19” rack mount products, end of row, mounts up to (2) 1U panels in Zero-U vertical orientation VP-BLNK1 . . . . . . . . . . . . . . .Vertical Blanking Panel, end-of-row Note: 2 Vertical Panels can be mounted vertically at the front and/or rear on each side of a single cabinet or at each end of multiple bayed cabinets. VP-VWM VP-VPP-2U VP-BLNK1 Vertical caBle ManageMent Part # Description VP-FGR(X) . . . . . . . . . . . . . . .Vertical Cable Management Fingers, length: 965.2mm (38 in.) (can be mounted alongside each VPP and/or VPC to facilitate routing of copper and fiber jumpers between patching fields as well as cabinet to cabinet connections) VP-VPC(X) . . . . . . . . . . . . . . .Vertical Patching Channel, with cable management fingers and cover, 177 mm x 996 mm (7 in. x 39.25 in.) VP-TRAY2 . . . . . . . . . . . . . . .Vertical Cable Management Tray (manages/secures cable between cabinets, use 4 trays to isolate airflow between cabinets) VP-FP . . . . . . . . . . . . . . . . . .Vertical Filler Panel used to fill additional space between vertical cable management trays on VP2 cabinets RS-VCM . . . . . . . . . . . . . . . . .Box of 10 quarter-turn hook and loop cable managers (can be installed in VP-TRAY2, VP-VPC and VP-VWM) VP-SPL . . . . . . . . . . . . . . . . .Quarter-Turn Fiber Management Spool, bag of five (can be installed in VP-VPC and VP-VWM panels) VP-FGR VP-VPC Use (X) to specify finger length: Blank = 4”(101.4mm) fingers, for use with VP1 or VP2 cabinets 6 = 6” (152.4mm) fingers, for use with VP2 cabinets only HOriZOntal caBle ManageMent Part # Description VP-SPL RS3-RWM(X)-1 . . . . . . . . . . .Single Sided 19” cable manager, 1U, dual hinged/removable cover RS3-RWM(X)-2 . . . . . . . . . . .Single Sided 19” cable manager, 2U, dual hinged/removable cover VP-TRAY2 13 RS-VCM RS3-RWM(X)-4 . . . . . . . . . . .Single Sided 19” cable manager, 4U, dual hinged/removable cover Use (X) to specify finger length: Blank = 4”(101.4mm) fingers, for use with VP1 or VP2 cabinets 6 = 6” (152.4mm) fingers, for use with VP2 cabinets only RS3-RWM-2 8 VersaPOD ® ORDERING INFORMATION Blanking PanelS Part # Description PNL-BLNK-1 VP-BLNK . . . . . . . . . . . . . . . .Vertical Blanking Panel,177mm x 996mm (7 in. x 39.25 in.) (fits in standard VPP opening between 2 bayed cabinets) PNL-BLNK-(X) . . . . . . . . . . . .Horizontal Blank Filler Panel, 19” (1 = 1U, 2 = 2U, 3 = 3U, 4 = 4U) acceSSOrieS VP-FAN Part # Description VP-FAN . . . . . . . . . . . . . . . . .Top-Mount Cooling Fan Panel, 3 fans, 15VAC 20/60 Hz 110 CFM, UL listed VP-BLNK VP-T3 . . . . . . . . . . . . . . . . . .127mm x 444mm (5 in x 17.5 in.) Brush Guard (for main top panel cable opening) VP-BRUSH . . . . . . . . . . . . . . .41.3m x 279mm (1.625 in. x 11 in.) Brush Guard (for perimeter top panel cable openings) VP-T3 VP-W . . . . . . . . . . . . . . . . . . .Castors, set of four VP-FT . . . . . . . . . . . . . . . . . .Leveling Feet, set of four VP-BAY . . . . . . . . . . . . . . . . .VP1 Baying Kit, bracket and hardware (secures 2 VP1 cabinets together) VP-W VP-FT VP-BAY2 . . . . . . . . . . . . . . . .VP2 Baying Kit, bracket and hardware (secures 2 VP2 cabinets together) VP-GRD . . . . . . . . . . . . . . . . .Grounding Kit - ground bar, ground wire, mounting hardware and accessories (capacity to support all required grounding connections for a single cabinet) VP-SB . . . . . . . . . . . . . . . . . .Stabilizing Brackets, set of four (secures cabinet to floor) VP-GRD RS-PO4 . . . . . . . . . . . . . . . . .Power Strip, North American, 1.2m (4 ft.) power strip, ten 15A outlets, resettable fuse, includes mounting hardware SH-S19-01 . . . . . . . . . . . . . .Single Sided Equipment Shelf - Solid -19 in. SH-S19V-01 . . . . . . . . . . . . .Single Sided Equipment Shelf - Vented -19 in. SH-S19V-01 NOTE: Visit www.siemon.com/versapod for a chart detailing the cable capacity of VersaPOD’s various cable entry points and cable management zones. RS-PO4 14 SIEMON WORLD WIDE LOCATIONS The AmericAs USA............................................................................(1) 866 474 1197 Canada.......................................................................(1) 888 425 6165 Colombia - Central and South America Main............(571) 317 2121 Argentina....................................................................(54) 11 5031 4061 Brasil..........................................................................(55) 11 3831 5552 Mexico.......................................................................(52) 55 2881 0438 Peru............................................................................(511) 275 1292 Venezuela...................................................................(58) 212 661 6538 europe, middle eAsT And AfricA United Kingdom.........................................................(44) (0) 1932 571771 Germany ....................................................................(49) 2241 97398311 France .......................................................................(33) 1 46 46 11 85 Italy .......................................................................(39) 02 64 672 209 Middle East................................................................(44) (0) 1932 571771 / (971) 506 441 470 AsiA pAcific Australia (Sydney) .....................................................(61) 2 8977 7500 Australia (Brisbane) ...................................................(61) 7 3854 1200 Australia (Melbourne)................................................(61) 3 9866 5277 Australia (Perth).........................................................(61) 8 9866 5277 Southeast Asia...........................................................(65) 6345 9119 China (Shanghai).......................................................(86) 21 5385 0303 China (Beijing) ..........................................................(86) 10 6559 8860 China (Guangzhou).........................................................(86) 20 3882 0055 China (Chengdu) .......................................................(86) 28 6680 1100 India...........................................................................(91) 11 46142162 / (91) 11 46142163 Japan .........................................................................(81) (3) 5798 5790 Visit our website at www.siemon.com for detailed global office contact information