Preview only show first 10 pages with watermark. For full document please download

Sik16me

   EMBED


Share

Transcript

Data sheet SIK 16ME Compact brine-to-water heat pump Order reference: SIK 16ME Installation location: Indoors Flow temperature max 58 °C Casing, powder-coated Heat pump for indoor installation with WPM 2007 plus integrated control and control panel that can also be used as a wired remote control using a wall-mounting kit (special accessory). Integrated brine components enable direct connection of the heat source: - Brine circulating pump (free compression 34000 Pa) - Expansion vessel (8 l) - Safety valve and pressure manometer. Sound-optimised through double vibration-isolated compressor, insulated metal casing and solid-borne sound insulation for direct connection to heating system; economiser for high COPs. Compact design with optimal DHW preparation and integrated components for easy connection of an unmixed heating circuit: - Heat circulating pump (free compression 64,500 Pa) - Overflow valve - Safety valve and pressure manometer - Expansion vessel, 24 l (must not be used for bivalent systems). Integrated soft starter, flow and return flow sensors; external sensor (standard NTC-2), dirt filter and large-capacity breather with micro air bubble deposition for sole circuit included in the scope of supply. Brine circuit manifold must be ordered separately. The heat pump complies with the valid standards and safety regulations as well as the Technical Specifications for Electrical Installations (TAB) of the electrical utility companies. Technical data SIK 16ME Dimplex Compact brine-to-water heat pump (Low temperature) Order reference Set-up / Colour Temperature operating limits for heating water / Brine Temperature operating limits for brine Heat output / COP at B0/W50* Heat output / COP at B0/W35* Electrical nominal power consumption at B0/W35 Refrigerant R407C Flow rate (heat source) at ext. pressure differential Heating water flow rate with an int. pressure differential of Dimensions (W x D x H)** Weight (incl. packing) Control voltage Supply voltage Starting current with soft starter Fuse Device connections for heating Device connections for heat source SIK 16ME kW/kW/kW kg m³/h / Pa m³/h / Pa Indoors / White (similar to RAL 9003) 58 °C / -5 °C -5 °C to 25 °C 15,50 / 2,90 15,80 / 4,20 3,77 2,30 3.5 / 13000 1.30 / 3500 mm kg V A A 652 x 653 x 1110 203 230 1/N/PE~230V, 50Hz 50 SA 32 1 1/4" 1 1/4" * The specified values have the following meaning, e.g. B0/W35: heat source temperature 0 °C, heat outlet temperature 35 °C. ** Please note that additional space is required for pipe connections, operation and maintenance. Glen Dimplex Deutschland GmbH Dimplex Division Am Goldenen Feld 18 95326 Kulmbach Page 1/4 Subject to change and errors! E-mail: [email protected] Internet: www.dimplex.de Internet: 26.07.2007 Phone: +49 (0)9221 709-201 Fax: +49 (0)9221 709-339 System accessories SIK 16ME Description Order ref. Article number Sample item SIK 16ME 353000 1 AP SVT SVT 200 SVT 300 SVT 400 SWPR 500 AFN 825 WT 733 348900 348910 348920 348930 337500 328610 349010 1 PSP 100E VSH KS VSW KS PSP 100K CTHK 631 PSW 200 PSW 500 HDLR 450 HCT 300 HL 16SK HL 26SK HL 36SK 353360 343110 343120 341900 336180 339830 339210 337450 351210 351780 351790 351800 WWSP 880 WWSP 442E WWSP 900 UP 80 KRRV 003 337880 353370 339220 340310 322070 PKS 14 VS PKS 342460 348630 FG 3115 RBG WPM FWPM 470 RDS LDS LDS USB 336620 339700 337470 353790 353770 353780 RKS WPM 342220 RTK 501 RTK 501 U 343080 350960 IN 01 WP 341750 Item Price Heat pumps Compact brine-to-water heat pump Heat source accessories Brine circuit manifold connection package 2-way brine circuit manifold 3-way brine circuit manifold 4-way brine circuit manifold Brine circuit low-pressure switch Brine circuit antifreeze (20 l) Plate heat exchanger using water as heat source in case of pollution 1 1 5 Hydraulic accessories Built-under buffer tank (100 l) for SI(K) 5-14* Compact brine heat pump connection set Hot water connection set for compact brine heat pump Built-under buffer tank (100l) 2 kW immersion heater for back-up heating Floor-mounted buffer tank (200 l)* Universal buffer tank (500 l)* Immersion heater pipe assembly* 3 kW radiator Fan convector for heating/cooling with external thermostat* Fan convector for heating/cooling with external thermostat* Fan convector for heating/cooling with external thermostat* 1 1 DHW preparation accessories Hot water cylinder (400 l) with temperature sensor* Design hot water cylinder (400 l)* Hot water cylinder (500 l) with temperature sensor* Circulating pump for main heat pump circuit Thermostat for heating and domestic hot water 1 Accessories for passive cooling Passive cooling station with cooling controller Passive cooling station for compact brine heat pump connection set 1 Control accessories External temperature sensor with casing Swimming pool / remote fault indicator relay module Heat pump manager remote control* Remote diagnostics hardware package Remote diagnostics hardware package (serial) Remote diagnostics hardware package (USB) Control accessories (cooling) Room climate control system for temperature and humidity measurement Heating/cooling on/off room temperature controller* Heating/cooling on-off room temperature controller in flat switch mounting frame for flush mounting* 1 Start-up (no discount available) Heat pump (heating only) start-up 1 * Other specific accessories available / required Notes: The heat source accessories are designed for ground heat collectors according to the project planning documentation. The free compression must be checked if the dimensions deviate or if borehole heat exchangers are used. Important information: The combination of the components and the quantities indicated represent a non-binding sample system, which needs to be tested and individually adapted as required. Pump dimensioning must be reviewed according to the pressure loss of the system and the minimum heating water flow rate of the heat pump. Glen Dimplex Deutschland GmbH Dimplex Division Am Goldenen Feld 18 95326 Kulmbach Page 2/4 Subject to change and errors! E-mail: [email protected] Internet: www.dimplex.de Internet: 26.07.2007 Phone: +49 (0)9221 709-201 Fax: +49 (0)9221 709-339 Brine-to-water heat pump, Integration Diagram, Heat pump and immersion heater SELECTED STEPS: 1. Brine-to-water heat pump 2. Compact design for quick and easy installation 3. Heat pump and immersion heater 4. Overflow valve 5. 1 heating circuit for a panel or radiator heating system 6. Without cooling 7. DHW with heat pump and flange heating for thermal disinfection 8. Heat pump manager with external temperature control Note: The given hydraulic integration schematic is a schematic representation of the key components and serves as an aid for planning your customized system. It does not contain all the required safety devices, the components needed to maintain constant pressure, or any other additional valves which may be required for maintenance and service work as stipulated by EN 12828. The heat pump manager settings and any external regulation system which may be connected must be adapted to the present integration diagram. Glen Dimplex Deutschland GmbH Dimplex Division Am Goldenen Feld 18 95326 Kulmbach Page 3/4 Subject to change and errors! E-mail: [email protected] Internet: www.dimplex.de Internet: 26.07.2007 Phone: +49 (0)9221 709-201 Fax: +49 (0)9221 709-339 Brine-to-water heat pump, Integration Diagram, Heat pump and immersion heater Legend: 1. 1.1 1.2 1.3 1.4 1.5 1.6 2. 3. 3.1 4. 5. 6. 7. 8. 9. 10. 13. Heat Pump Air-to-water heat pump Brine-to-water heat pump Water-to-water heat pump Reversible air-to-water heat pump Reversible brine-to-water heat pump Reversible water-to-water heat pump Heat pump manager Buffer tank Parallel buffer tank Hot water cylinder Swimming pool heat exchanger Passive cooling station with cooling controller N6 Heating and silent or dynamic cooling Fan convector with 4-wire connection Cooling circuit only Heating circuit only Heat source Domestic hot water distribution system: DDV 32 EB KPV KPV 25 MMB 25 MMH 25 SST 25 VTB 25 WWM 25 Dual differential pressureless manifold (up to 2.5 m³/h)* Extension module for compact manifold (up to 2.0 m³/h)* Compact manifold with overflow valve (up to 1.3 m³/h)* In combination with EB KPV (up to 2.0 m³/h)* Mixer module, bivalent (up to 2.0 m³/h)* Mixer module for heating circuit Solar station for hot water Manifold bar (up to 2.5 m³/h)* Hot water module / unmixed heating circuit (up to 2.5 m³/h)* * Recommended max. heating waterflow Glen Dimplex Deutschland GmbH Dimplex Division Am Goldenen Feld 18 95326 Kulmbach E9 E10 E10.1 E10.2 E10.3 E10.5 F7 K20 K21 M11 M12 M13 M14 M15 M16 M17 M18 M19 MA MZ N1 N2 N3/N4 N6 N12 R1 R2 R3 R4 R5 R9 R11 R13 TC Y5 Y6 Y7 Y8 Page 4/4 Subject to change and errors! E-mail: [email protected] Internet: www.dimplex.de Flange heater, hot water 2nd heat generator (HG2) Immersion heater Oil/gas boiler Solid fuel boiler Solar energy system Safety temperature monitor Contactor for 2nd heat generator Contactor for immersion heater hot water Primary pump for heating operation Primary pump for cooling operation Heat circulating pump for main circuit Heat circulating pump for heating circuit 1 Heat circulating pump for heating circuit 2 Auxiliary circulating pump Cooling circulating pump Hot water circulating pump Swimming pool water circulating pump Mixer open Mixer closed Heating controller Cooling controller for reversible heat pumps Room climate control stations Cooling controller for passive cooling Solar controller External wall sensor Return flow sensor Hot water sensor Return flow sensor for cooling water Temperature sensor for heating circuit 2 Flow sensor (antifreeze) Flow sensor for cooling water Sensor for heating circuit 3 / bivalent-renewable Room temperature controller Three-way distribution valve Two-way valve Three-way mixing valve Three-way valve (closing time max. 10 sec.) Internet: 26.07.2007 Phone: +49 (0)9221 709-201 Fax: +49 (0)9221 709-339