Our communication channels give access to the data of SIMATIC S5, SIMADYN D, SICOMP or SIMATIC TDC programmable controllers via SIMATIC WinCC. This speeds up migration from COROS LS-B to SIMATIC WinCC.
The challenge You use WinCC as your visualization system and would like to connect SIMATIC S5, SIMADYN D, SICOMP or SIMATIC TDC programmable controllers to it. You use COROS LS-B as your visualization system and would like to replace it with WinCC. You hope to benefit from the migration with enhanced functionality, cheaper spare parts, open interfaces and broad service and support offerings. At the same time, you would like to continue using your existing programmable controllers.
Our solution Our communication channels enable you to connect SIMATIC S5, SIMADYN D, SICOMP or SIMATIC TDC programmable controllers to WinCC – and migrate quickly and smoothly from COROS LS-B to WinCC without having to reprogram the PLC. PMC communications protocol Our communication channels connect your programmable controllers to WinCC using PMC, the standardised I&C protocol.
Good reasons for SIMATIC WinCC communication channels: 쮿 PMC – the standardized I&C protocol – is used 쮿 Rapid migration from COROS LS-B without having to reprogram the programmable controller (PLC) 쮿 Messages are generated in the PLC synchronously with the event, stamped with the time of their occurance and sent independently 쮿 Low communication volume because check back signals are controlled by the PLC (no need for cyclic OS requests) 쮿 Messages are centrally acknowledged on all OS stations
The following PMC functions are supported: 쮿 Read – The PLC is prompted by means of a PMCREAD request message frame to send data to WinCC. WinCC responds to this request automatically, and if necessary cyclically. 쮿 Write – The PLC is prompted by means of a PMCWRITE request message frame to accept data from WinCC. 쮿 Alarms – The PLC forwards process controlled messages to WinCC. It differentiates between process messages and system messages. Messages are stamped in the PLC with the time of their occurrence.
쮿 Short-term archiving – Process values with a very short cycle time can be recorded in the PLC and stored block by block in the WinCC trend archive. 쮿 Link monitoring – The data link between WinCC and the PLC can be monitored by means of a sign-of-life 쮿 Status messages (SIMATIC S5 only) – Status messages are converted to WinCC tags that can be directly switched to the group display. 쮿 Clock synchronization (SIMATIC S5 only) – Either WinCC or the PLC can be used as the time-of-day master to synchronize the link device. 쮿 Time assimilation of time stamps between PLC and SIMATIC WinCC (alarms, archiv data, clock time telegram).
SIMATIC WinCC PMC communication channels Connecting SIMATIC S5, SIMADYN D, SICOMP and SIMATIC TDC to SIMATIC WinCC Industrial Technologies
080598_WinCC_RZ04.indd 1
16.07.2008 9:54:16 Uhr
Communication channel Hardware requirements
Software requirements
SIMATIC S5 PMC
SIMADYN D PMC
Industrial Ethernet: CP 1613 (PCI card), CP 1613 (A2)
Industrial Ethernet: CP 1613 (PCI card), CP 1613 (A2)
PROFIBUS: CP 5613 (A2), CP 5614 (A2) WinCC system software: Version 6.00 or higher for Windows 2000, Windows XP and Windows 2003 server
SICOMP RMOS3
PROFIBUS: CP 5613 (A2), CP 5614 (A2)
TCP/IP Board: All network cards supported under Windows 2000, Windows XP and Windows 2003 server
TCP/IP Board: All network cards supported under Windows 2000, Windows XP and Windows 2003 server
WinCC system software: Version 4.02 or higher
WinCC system software: Version 5.0 or higher
WinCC system software: Version 6.0 or higher
SIMATIC NET: Driver for CP S7-1613/S7-5613
SIMATIC NET: Driver for CP
SIMATIC NET: Driver for CP
SIMATIC TDC: STEP 7 Version 5.0 or higher with D7-SYS V5.1
SICOMP: RMOS3 V3.30.02 Rev 24 or higher PMC Stack V1.1
SIMATIC NET: Driver for CP S7-1613/S7-5613
SIMADYN D: STRUC G/L kit, Version 4.2 for Data handling block in the PLC: SCO-Unix with HMI 4.3 blocks PMC data handling blocks, PROBI: PMCPro V2.2 or higher The PROBI configuration kit PMC/LS-B standard software: Message functions
SIMATIC TDC PMC
is a component of SIMADYN D PMC
PROBI: The PROBI configuration kit is a component of SIMATIC TDC PMC
optional: PMC/LS-B standard software: status and objects Easy migration from COROS LS-B: The PLC configuration remains unchanged, messages and tags are imported into WinCC using the address import tool supplied
Easy migration from COROS LS-B: The PLC configuration remains unchanged, messages and tags are imported into WinCC using the address import tool supplied
SIMATIC S5 PMC IE (Industrial Ethernet): 2XV9450-1WC43-0JX0
SIMADYN D PMC IE (Industrial Ethernet): 2XV9450-1WC43-0AX0
SIMATIC S5 PMC PB (PROFIBUS): 2XV9450-1WC43-0EX0
SIMADYN D PMC PB (PROFIBUS): 2XV9450-1WC43-0BX0
Upgrade from SIMATIC WinCC V6.0 to WinCC V6.2
SIMATIC S5 PMC IE V6.2 Upgrade (Industrial Ethernet): 2XV9450-1WC43-0JX2
SIMADYN D PMC IE V6.2 Upgrade (Industrial Ethernet): 2XV9450-1WC43-0AX2
SIMATIC S5 PMC PB V6.2 Upgrade (PROFIBUS): 2XV9450-1WC43-0EX2
SIMADYN D PMC PB V6.2 Upgrade (PROFIBUS): 2XV9450-1WC43-0BX2
Upgrade from SIMATIC WinCC V6.0 to WinCC 7.0
SIMATIC S5 PMC IE (Industrial Ethernet): 2XV9450-1WC43-1JX1
SIMADYN D PMC IE (Industrial Ethernet): 2XV9450-1WC43-0AX1
SIMATIC S5 PMC PB (PROFIBUS): 2XV9450-1WC43-1EX1
SIMADYN D PMC PB (PROFIBUS): 2XV9450-1WC43-0BX1
SIMATIC WinCC V7.0
SIMATIC S5 PMC IE V7.0 (Industrial Ethernet): 2XV9450-1WC43-0JX7
SIMADYN D PMC IE V7.0 (Industrial Ethernet): 2XV9450-1WC43-0AX7
SIMATIC S5 PMC PB V7.0 (PROFIBUS): 2XV9450-1WC43-0EX7
SIMADYN D PMC PB V7.0 (PROFIBUS): 2XV9450-1WC43-0BX7
Special features
SIMATIC WinCC V6.0
Symbolic addressing: Message with up to 8 values/ text Text, structures and arrays with up to 1.400 bytes
SIMATIC TDC PMC TCP/IP: 2XV9450-1WC43-0KX0
RMOS3 PMC: 2XV9450-1WC43-0RX0
SIMATIC TDC PMC TCP/IP V6.2 Upgrade: 2XV9450-1WC43-0KX2
RMOS3 PMC V6.2 Upgrade: 2XV9450-1WC43-0RX2
SIMATIC TDC PMC TCP/IP: 2XV9450-1WC43-0KX1
RMOS3 PMC: 2XV9450-1WC43-0RX1
SIMATIC TDC PMC TCP/IP V7.0: 2XV9450-1WC43-0KX7
RMOS3 PMC V7.0: 2XV9450-1WC43-0RX7
For further SIMATIC WinCC channel versions (even older ones), please ask IT4Industry. Siemens AG Industry Sector Industry Solutions Division Industrial Technologies I IS IN E&C IT4Industry Customer Support P.O. Box 32 40 91050 Erlangen, Germany Phone: +49 (0) 9131 7-46111 Fax.: +49 (0) 9131 7-44757 E-Mail:
[email protected]
© Siemens AG 2008 All rights reserved Order No.: E10001-T480-A122-V2-7600 Printed in Germany Dispo No.: 21646 K No.: 37500 GB C-ISEC5208M01 DA 0708.5 Subject to change without prior notice
IT4Industry is a trademark of Siemens AG.
The information provided in this brochure contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract.