Preview only show first 10 pages with watermark. For full document please download

Similar Pages

   EMBED


Share

Transcript

catalogue4.fm Page 34 Tuesday, March 26, 2002 12:07 AM AT serie DIMENSIONAL DRAWING M30x1,5 M30x1,5 M30x1,5 7 12 SW36 SW36 38 60 SW36 38 7 6 12 12 6 60 7 6 38 AT 60 SERIE 10 16 8 7 15 Ø11 5 Ø2 10 13 Ø5,5 5 2 10 1.1 4 5 Ø5,5 4 1 M12x1 Ø13,5 2 3 Inductive proximity sensors M30 - DC ◆ ◆ ◆ ◆ ◆ ◆ Metal housing Axial cable exit with and without tang M12 metal plug cable exit LED status indicator 360° visible IP67 protection degree Complete protection against electrical damages AT1/**-*A AT1/**-*B AT1/**-*H Key 1 Axial cable exit 2 Axial cable exit with tang 3 M12 plug cable exit 4 Cable 4x0,34mm2, Ø5,5mm, PVC, 2m 5 LED status indicator (NO output energized) 6 Shielded version 7 Unshielded version Connectors series CD serie Accessori series ST serie ORDERING SYSTEM A T 1 / AN - 1 A serie M30 inductive proximity sensor cable exit AT1 output state NO output state NC output state A C A B H axial cable exit axial cable exit with tang M12 plug cable exit 1 2 standard shielded 10mm unshielded 15mm logic NPN output PNP output sensing range N P 34 catalogue4.fm Page 35 Tuesday, March 26, 2002 12:07 AM inductive proximity sensors SPECIFICATIONS Model Nominal sensing distance Sn Operating distance Differential travel Repeat accuracy Operating voltage Ripple No-load supply current Load current Leakage current Voltage drop Output type AT1/**-1* AT1/**-2* 10mm 15mm 8,1mm (shielded), 12,1mm (unshielded) 2...10% 2% 10-30Vdc ≤10% 20mA ≤400mA £10µA ≤1V max. NPN or PNP NO or NC 200Hz 100ms polarity reversal, transient short circuit (autoreset) -25°...+70°C 10% Sr IEC IP67 Yellow (NO output energized) nickel-plated brass PBT 60Nm 180 (A, B type); 110 (H type) (1) Switching frequency Time delay before availability Supply electrical protections Output electrical protections Temperature range Temperature drift Protection degree (DIN 40 050) LED indicators Housing material Sensing face material Tightening torque Weight (approx.) 1.1 (1) with 30x30mm FE360 target. CHARACTERISTIC CURVES Distance / target size -5 -7,5 -10 -12,5 0 2,5 5 7,5 10 Distance X (mm) 20 10 Inox 8 6 CuZn Al 4 Cu 2 0 0 10 20 30 40 50 60 70 10 7,5 5 2,5 0 -2,5 -5 -7,5 -10 -12,5 0 5 Target dimensions (mm) 10 15 Distance Xon(mm) 0 -2,5 Fe360 Distance Y (mm) 5 2,5 Distance / target size 12,5 AT*/**-2* 7,5 Distance Xon(mm) 10 AT*/**-1* DistanzceY (mm) AT*/**-1* Detection area 12 AT*/**-2* Detection area 12,5 Fe360 Inox 10 CuZn Al Cu 0 0 10 20 Distance X (mm) WIRING DIAGRAMS 30 40 50 60 70 Target dimensions (mm) CONNECTORS NPN output NO PNP output BN/1 BN/1 M12 (H type) (OUT NO) Supply ( - ) D R LED BK/4=NO L 3 1 2 Z C T BK/4=NO BK/2=NC NPN out T 4 R BU/3 Supply ( + ) BK/2=NC LED Z PNP out D BU/3 L C NC M12 (H type) Supply ( - ) The max. admissible capacity C = 1µF for max. output voltage and current. Supply ( + ) 35 4 3 1 2 (OUT NC)