Preview only show first 10 pages with watermark. For full document please download

Similar Pages

   EMBED


Share

Transcript

TPZ 111 TELEMETRY KEYBOARD OPERATING INSTRUCTIONS v2.0 CONTENTS Safety precautions..................................................................................................................2 Preface...................................................................................................................................3 Features .................................................................................................................................3 Precautions ............................................................................................................................3 Controls and cables................................................................................................................4 Rear panel .......................................................................................................................4 Connections ...........................................................................................................................5 Specifications .........................................................................................................................5 Installation ..............................................................................................................................6 AC power supply..............................................................................................................6 Pan&Tilt head ..................................................................................................................6 Lens.................................................................................................................................6 Jumper settings ...............................................................................................................6 SAFETY PRECAUTIONS In order to prevent any fatal accidents caused by misoperation or mishandling of the telemetry keyboard, be fully aware of all the following precautions. WARNING: THIS APPARATUS MUST BE EARTHED WARNING: To prevent fire or shock hazard, do not expose this appliance to rain or moisture. This unit is produced to comply with Directives 93/68/EEC (IEC Publ.65) and 89/336/EEC. 2 PREFACE PRECAUTIONS The TPZ 111 is a simple Telemetry Keyboard that allows Pan&Tilt and Lens control connected directly to Pan&Tilt motors and motor-driven Lenses with common ground or polarity inversion Lens controls. Pan&Tilt and Lens are supplied directly from the Telemetry Keyboard.. • Use only the power source specified on the rating label located on the bottom plate of the cabinet. • When not using this unit for a long period of time, or when cleaning it, be sure to disconnect the AC power supply. • Avoid using this unit under the following conditions: -in extremely hot, cold or humid places, -in dusty places, -near appliances generating strong magnetic fields, -in places subject to direct sunlight, and -in badly ventilated places. • Unplug this unit from the AC power supply and refer servicing to qualified service personnel under the following conditions: -when the power cord is frayed -if the unit does not operate normally following the operating instructions -if the unit has been dropped or the cabinet has been damaged -when the unit exhibits a distinct change in performance. FEATURES • • • • • • Simple Installation 11 Keys 2 LEDs P&T Control Lens Control 24VAC or 230VAC, 50/60 Hz Power Supply 3 CONTROLS AND CABLES 1 2 8 3 9 4 10 5 11 6 12 7 13 REAR PANEL 14 15 16 (9) ↑ - P&T control - UP. (10) → - P&T control - RIGHT. (11) AUTO - a key to select the AUTO mode of the Pan&Tilt control. (12) ↓ - P&T control - DOWN. (13) ← P&T control - LEFT. (14) 7-wires Pan&Tilt control cable. (15) 3-wires power supply cable. (16) 6-wires Lens control cable. (1) LED - lights when the power supply is switched on. (2) IRIS / OPEN - Iris control - OPEN. (3) ZOOM / IN - Zoom control - IN. (4) FOCUS / NEAR - Focus control - NEAR. (5) FOCUS / FAR - Focus control - FAR. (6) ZOOM / OUT - Zoom control - OUT. (7) IRIS / CLOSE- Iris control - CLOSE. (8) LED - lights when the AUTO mode is selected. 4 CONNECTIONS • Be sure to disconnect the AC power supply before connecting to other equipment. • Also refer to the instruction manual of the equipment to be connected. MON CAM AC MAINS SPECIFICATIONS Number of Keys Number of LEDs P&T Control Output Lens Control Output Power requirement Consumption Dimensions (W x H x D) Weight 11 (foil) 2 24VAC or 230VAC, 50/60 Hz 6VDC / 12VDC 24VAC or 230VAC, 50/60 Hz 4W 145 x 49 x 182 mm 0.5 kg 5 INSTALLATION AC POWER SUPPLY AC INPUT L N EARTH WIRE COLOR (14) BROWN BLUE YELLOW/GREEN PAN&TILT HEAD PAN&TILT CONTROL LEFT RIGHT UP DOWN AUTO COMMON EARTH WIRE COLOR (15) GREY WHITE PINK BROWN GREEN BLUE YELLOW LENS CONTROL COMMON GROUND IRIS ZOOM FOCUS COMMON COMMON COMMON WIRE COLOR (16) PINK YELLOW BROWN GREY GREEN WHITE LENS LENS CONTROL POLARITY INVERSION IRIS ZOOM FOCUS IRIS ZOOM FOCUS JUMPER SETTINGS Lens control voltage 6V DC: 12V DC: 6 WIRE COLOR (16) PINK YELLOW BROWN GREY GREEN WHITE 7 ASTEL d.o.o., Dutovlje 138, 6221 Dutovlje, Slovenia Tel: +386 5 7310771, +386 5 7310772 Fax:+386 5 7310789 E-mail: [email protected] Web: www.astel-cctv.com 8