WP10-12SE 12Volt 10Ah Specifications Nominal Voltage(V) 12V Nominal Capacity (0.5A to 10.50V) 10Ah 10 hour rate (0.95A 5 hour rate (1.7A to 10.50V) 9.5Ah to 10.20V) 8.5Ah 1 hour rate (6A to 9.60V) 6Ah 1 C (10A to 9.60V) 6.33Ah 3 C (30A to 9.60V) 4Ah Weight Approx. 3.3kg(7.26Lbs.) Approx. 12 mΩ Dimensions 5 seconds: 4.75 (0.19) Maximum Discharge Current for mm(inch) 135A 0.8 (0.03) Charging Methods at 25℃(77℉) 6.35 (0.25) Internal Resistance (at 1KHz) 0.8 (0.03) 20 hour rate F1 Cycle use: Charging Voltage F2 14.4 to 15.0V Coefficient -5.0mv/℃/cell Maximum Charging Current: 3.0A Standby use: Float Charging Voltage 13.50 to 13.80V 65±1(2.56±0.04) 151±1(5.94±0.04) Operating Temperature Range Charge -15℃(5℉) to 40℃(104℉) Discharge -15℃(5℉) to 50℃(122℉) Storage -15℃(5℉) to 40℃(104℉) (v) FOR 12V BATTERY Charge Retention (shelf life) at 20℃(68℉) 112±1(4.40±0.04) 118.5±1(4.67±0.04) Coefficient -3.0mv/℃/cell Discharge Time VS. Discharge Current (25℃) 13.0 1 month 92% 3 month 90% 6 month 80% 12.0 11.0 0.95A Case Material ABS (Option: UL94 HB & UL94 V-0 flame retardant ) 10.0 30A F1 or F2 (Faston Tab 187 or 250) 10A 6A 9.0 8.0 Terminal 0.5A 1.7A 1 2 4 6 8 10 20 40 60 2 minutes 4 6 8 10 hours Discharge Time 20 WP10-12SE Effect of Temperature on Capacity 25℃(77℉) (%) 100 120 0.05CA 0.1CA 0.6CA 1CA 60 2CA 40 20 -20 -4 -10 14 0 32 10 50 20 68 30 86 40 50 104 122 ℃ ℉ 0 ℃(32 ℉) Remaining Capacity 0.25CA 80 Temperature 75 10 ℃(50 ℉) 50 20 ℃(68 ℉) 40 ℃(104 ℉) 0 3 6 Capacity % 2 12 15 18 Cycle Service Life (1) Discharge : 0.17CA (2) Charge : CV 2.4V/cell*16H Imax 0.3CA (3) End of life discharge voltage : 1.65 Vpc (4) Temperature : 25±2℃ 120 3 9 Storage Time (months) 10 5 30℃(86℉) 25 Trickle (or float) Service Life Life (years) Capacity % 100 0 Capacity Retention Characteristic 100 80 60 Discharge Depth 10 0% Discharge Depth 50% Discharge Depth 30 % 40 20 0.5 0 20 68 30 86 40 104 50 122 (℃) (℉) 0 200 400 600 800 1000 1200 Number of Cycles (times) Ambient Temperature 120612-1A Head Quarter Service TEL: +886-49-2254-777 USA Customer Service TEL: +1-949-328-7936 Vietnam Customer Service - TEL: +84-72-3779666 FAX: +886-49-2255-139 FAX: +1-949-266-9917 FAX: +84-72-3779476 E-mail: [email protected] E-mail: [email protected] E-mail: [email protected] Contents in this data sheet are subject to change for improvement without prior notice to users. For clarifications and updated information, please contact us.