Transcript
JS
VDE
MINIATURE PC BOARD TYPE POWER RELAY
22 .866
JS RELAYS
FEATURES
16 .630
• Miniature size with universal terminal footprint • High contact capacity: 10 A • TV-5 type available (Standard type) 1 Form A type → TV-5 1 Form C type → TV-5 (N.O. side only) • VDE, TÜV also approved • Sealed construction for automatic cleaning (Standard type) • Class B and F coil insulation type also available. • EN60335-1 GWT compliant (Tested by VDE) type available • Surge voltage 6 kV type also available
16 .630
mm inch
RoHS Directive compatibility information http://www.nais-e.com/
About Cd-free contacts We have introduced Cadmium free type products to reduce Environmental Hazardous Substances. (The suffix “F” should be added to the part number) Please replace parts containing Cadmium with Cadmium-free products and evaluate them with your actual application before use because the life of a relay depends on the contact material and load.
SPECIFICATIONS Characteristics
Contact Types Arrangement Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact material Nominal switching capacity Rating Max. switching power (resistive Max. switching voltage load) Max. switching current Min. switching capacity#1 Mechanical (at 180 cpm) Electrical at 10 A 125 V AC, 6 A 277 V AC resistive Expected (standard) life (min. 10 A 277 V AC resistive ope.) (High power) 10 A 250 V AC resistive (Standard: at 20 cpm) (High power: at 20 cpm, 105°C 221°F)**
Standard type
Long endurance type
1 Form A, 1 Form C
1 Form A
Max. operating speed Types
100 mΩ AgSnO2 type 10 A 250 V AC 10 A 250 V AC 10 A 125 V AC 10 A 125 V AC 6 A 277 V AC 10 A 277 V AC 2,500 VA 250 V AC, 100 V DC 10 A (AC), 5 A (DC)
Initial insulation resistance Between open contacts Initial breakdown Between contacts and voltage*1 coil Operate time*2 (at nominal voltage) Release time (without diode)*2 (at nominal voltage)
Temperature rise (at nominal voltage) 100 mA, 5 V DC 107 Shock resistance
Functional*3 Destructive*4 Functional*5
1×105
2×105
Vibration resistance Destructive
5 × 104 (No contact only)
1.2 × 105
** Holding voltage should be 60% V of nominal voltage
360 mW
#1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
Remarks *1 Detection current: 10mA *2 Excluding contact bounce time
Ambient temp.*7 Humidity
Unit weight
Coil Nominal operating power
Conditions for operation, transport and storage*6 (Not freezing and condensing at low temperature)
20 cpm Standard Long type endurance type Min. 100 MΩ (at 500 V DC) 750 Vrms for 1 min. 1,500 Vrms for 1 min. Max. 10 ms Max. 10 ms Max. 35°C, resistive, nominal voltage applied to coil. Contact carrying current: 10A, at 70°C 158°F 98 m/s2 {10 G} 980 m/s2 {100 G} 10 to 55 Hz at double amplitude of 1.6 mm 10 to 55 Hz at double amplitude of 2 mm –40°C to –40°C to +85°C +105°C –40°F to –40°F to +185°F +221°F 5 to 85% R.H. Approx.12 g .423 oz
*3 Half-wave pulse of sine wave: 11ms; detection time: 10µs *4 Half-wave pulse of sine wave: 6ms *5 Detection time: 10µs *6 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT *7 When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1°C 33.8°F with 20°C 68°F as a reference) and use a coil impressed voltage that is within the maximum allowable voltage range.
TYPICAL APPLICATIONS 1. Home appliances Air conditioner, heater, etc.
2. Automotive Power-window, car antenna, door-lock, etc.
3. Office machines PPC, facsimile, etc. 4. Vending machines
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
JS ORDERING INFORMATION Ex. JS
Contact arrangement 1: 1 Form C (Standard) 1a: 1 Form A (Standard) 1aP: 1 Form A (Long endurance type)
1a
F
B
Protective construction
Coil insulation class
Nil: Sealed type F: Flux-resistant type
Nil: Class E insulation B: Class B insulation F: Class F insulation
12V
F
Coil voltage (DC)
Contact material
Flame resistance and tracking resistance
Surge voltage
5, 6, 9, 12, 18, 24, 48 V
F: AgSnO2 type
Nil: — T: EN60335-1 (Conform)
6K: 6kV type
Standard: UL/CSA, VDE, TÜV (Standard type) UL/CSA, VDE (Long endurance type and EN60335-1 GWT compliant type) UL/CSA (Surge voltage 6kV type) Notes: 1. Standard packing: Carton: 100 pcs. Case: 500 pcs. 2. When ordering TV rated (TV-5) types, please consult us. 3. Contact arrangement 1aP type is Flux-resistant type only (Class B insulation only). 4. Please inquire about the previous products (Cadmium containing parts).
COIL DATA Part No. Standard type Sealed type 1 Form A JS1a-5V-F JS1a-6V-F JS1a-9V-F JS1a-12V-F JS1a-18V-F JS1a-24V-F JS1a-48V-F
1 Form C JS1-5V-F JS1-6V-F JS1-9V-F JS1-12V-F JS1-18V-F JS1-24V-F JS1-48V-F
Flux-resistant type 1 Form A JS1aF-5V-F JS1aF-6V-F JS1aF-9V-F JS1aF-12V-F JS1aF-18V-F JS1aF-24V-F JS1aF-48V-F
1 Form C JS1F-5V-F JS1F-6V-F JS1F-9V-F JS1F-12V-F JS1F-18V-F JS1F-24V-F JS1F-48V-F
Nominal Pick-up Drop-out Coil Nominal Max. Long endurance operating Nominal voltage, voltage, resistance, operating allowable type current, voltage, V DC (max.) V DC (min.) Ω (±10%) power, mW voltage mA (±10%) Flux-resistant V DC (at 20°C (at 20°C (at 20°C (at 20°C (at 85°C (at 20°C type 68°F) 68°F) 68°F) 68°F) 185°F) 68°F) 1 Form A JS1aPF-B-5V-F 5 3.5 0.5 69.4 72 JS1aPF-B-6V-F 6 4.2 0.6 100 60 130%V JS1aPF-B-9V-F 9 6.3 0.9 225 40 of 360 JS1aPF-B-12V-F 12 8.4 1.2 400 30 nominal JS1aPF-B-18V-F 18 12.6 1.8 900 20 voltage JS1aPF-B-24V-F 24 16.8 2.4 1,600 15 JS1aPF-B-48V-F 48 33.6 4.8 6,400 7.5
Notes) 1. Class B and F coil insulation types available. Ex) JS1aF-B-12V-F JS1aF-F-12V-F 2. EN60335-1 GWT compliant types available. When ordering, please add suffix “T”. Ex) JS1aF-B-12V-FT 3. Surge voltage 6kV types available. When ordering, please add suffix “6K” (except for Long endurance type and EN60335-1 GWT compliant type). Ex) JS1aF-B-12V-F-6K
DIMENSIONS
mm inch
PC board pattern (Bottom view)
Schematic (Bottom view) 1a
1a N.O.
16 .630 0.4 .016
COIL
(Standard, High Power) 4-1.3 dia. 4-.051 dia.
COM
3.9 .154 0.24 .009
12 .472 0.8 .031
0.8 .031
1c N.O. 0.4 .016
2 16 .630 1.2 .047 2.3 .091
COIL
12 .472
12.2 .480
1c
3 N.O.
1
2 .079
COM
N.C.
(Standard)
4 N.C.
5
5-1.3 dia. 5-.051 dia. 0.4 .016
2 .079
12.2 .480 22 .866
Note: Terminal No. 4 is only for Standard 1 Form C type General tolerance: ±0.3 ±.012
12 .472
2 .079
12.2 .480
Tolerance: ±0.1 ±.004
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
JS REFERENCE DATA 1. Maximum value for switching capacity
2. Operate/release time
3. Life curve
Sample: 25 pcs., JS1-12V-F
Ambient temperature: Room temperature 100
10
1
DC resistive load
10 Operate time
125V AC resistive load
8
Life, ×104
AC resistive load
Operate/release time, ms
Contact current, A
100
6 4
Max. – x Min. Max. – x Min.
Release time 2
10
30
0
100
80
Contact voltage, V
100
10
120
1
140
0
1
2
3
4
5
6
7
8
9
4-(2). Coil temperature rise
5. Ambient temperature characteristics
Sample: 5 pcs., JS1a-24V-F Measured portion: Inside the coil Contact current: 5 A
Sample: 5 pcs., JS1a-24V-F Measured portion: Inside the coil Contact current: 10 A
Sample: 6 pcs., JS1-12V-F
60
26°C 70°C 85°C
40 30
Temperature rise, °C
Temperature rise, °C
26°C 50
50
70°C 85°C
Changing ration, %
4-(1). Coil temperature rise
60
40
10
30
–10
10
10
–20
120
140
Coil applied voltage, %V
160
0
Drop-out voltage
20 40 60 80
20
100
Pick-up voltage 20
–60 –40 –20 0
20
0
10
Contact current, A
Coil applied voltage, %V
100
120
140
160
Coil applied voltage, %V
For Cautions for Use, see Relay Technical Information
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
Ambient temperature °C