Transcript
PRODUCT DATASHEET 1-800-383-7323 USA/CAN www.energizer.com
ENERGIZER CR1616
Lithium Coin Specifications Classification: Chemical System: Designation: Nominal Voltage: Typical Capacity:
Industry Standard Dimensions mm (inches)
This Battery has Underwriters Laboratories component Recognition
Typical Weight: Typical Volume: Max Rev Charge: Energy Density: Typical Li Content: UL Recognized: Operating Temp: Self Discharge:
"Lithium Coin" Lithium / Manganese Dioxide (Li/MnO2) IEC-CR1616 3.0 Volts 55 mAh (to 2.0 volts) (Rated at 30K ohms at 21°C) 1.1 grams (0.04 oz.) 0.32 cubic centimeters (0.02 cubic inch) 1 microampere 133 milliwatt hr/g, 498 milliwatt hr/cc 0.014 grams (0.0005 oz.) MH29980 -30C to 70C ~1% / year
1.60 (0.063)
Safety:
16.00 (0.630)
1.40 (0.055) Ref.
15.70 (0.618)
5.00 (0.197) Minimum
1.10 (0.043) Ref.
0.20 (0.008) Maximum Ref. Permissible deflection from a flat. 0.03 Minimum Ref. (Applies to top edge of gasket or edge of crimp, whichever is higher.)
Simulated Application test Typical Performance at 21°C (70°F)
Schedule:
Continuous
Typical Drains: at 2.9V (mA)
(ohms)
Cutoff 2.0V (hours)
0.097
30,000
567
Load
(1) KEEP OUT OF REACH OF CHILDREN. Swallowing may lead to serious injury or death in as little as 2 hours due to chemical burns and potential perforation of the esophagus. Immediately see doctor; have doctor phone (202) 625-3333. (2) Battery compartment design. To prevent children from removing batteries, battery compartments should be designed with one of the following methods: a) a tool such as screwdriver or coin is required to open battery compartment or b) the battery compartment door/cover requires the application of a minimum of two independent and simultaneous movements of the securing mechanism to open by hand. Screws should remain captive with the battery door or cover.
Internal Resistance Characteristics Pulse Test at 21°C (70°F)
Bkgnd Drain: Continuous 30K ohms 0.097 mA @2.9V
Typical Discharge Characteristics
Pulse Drain: 2 seconds X 12 times/day 400 ohms 6.6 mA @2.65V
3.2 3.0 2.8 2.6 2.4 2.2 2.0 1.8
Voltage, CCV
Voltage, CCV
Load: 30K ohms - Continuous Typical Drain @ 2.9V: 0.097 mA
0
100
200 300 400 Service, Hours
500
600
3.2 3.0 2.8 2.6 2.4 2.2 2.0 1.8
120
Bkgnd
100 80
Pulse
60 40 20
IR 0
Important Notice
5
0
10 15 20 25 30 35 40 45 50 55 60 Capacity, mAh
This datasheet contains typical information specific to products manufactured at the time of its publication. ©Energizer Holdings, Inc. - Contents herein do not constitute a warranty.
Form No. EBC - 4115I
Page 1 of 1
IR, ohms
1.40 (0.055)